INSTRUCTION MANUAL
BEDIENUNGSANLEITUNG
MANUEL D’INSTRUCTIONS
VCC-4115P
COLOUR CCD camera
CCD-Farbkamera
Caméra CCD COULEUR
CCD
About this manual
Before installing and using the camera, please read this manual
carefully. Be sure to keep it handy for later reference.
A propos de ce manuel
Avant d’installer et d’utiliser la caméra, veuillez lire ce
manuel attentivement. Gardez-le à portée de main pour
toute référence ultérieure.
Über diese Bedienungsanleitung
Lesen Sie bitte vor der Montage und dem Inbetriebnehmen der
Kamera zuerst diese Bedienungsanleitung sorgfältig durch und
bewahren Sie sie zum späteren Nachschlagen auf.
Download from Www.Somanuals.com. All Manuals Search And Download.
PRECAUTIONS
I In case of problem
I Protect from humidity and dust
Do not use the camera if smoke or a strange odour comes
from the unit, or if it seems not to function correctly. Disconnect
the power cord immediately, and consult your dealer (or a
Sanyo Authorized Service Centre).
To prevent damages to the camera, do not install it where
there is greasy smoke or steam, where the dampness may get
too high, or where there is a lot of dust.
I Protect from high temperatures
I Do not open or modify
Do not install close to stoves, or other heat generating devices,
such as spotlights, etc., or where it could be subject to direct
sunlight, as that could cause deformation, discoloration or
other damages.
Do not open the cabinet, as it may be dangerous and cause
damage to the unit. For internal settings and repairs, consult
your dealer (or a Sanyo Authorized Service Centre).
Be careful when installing close to the ceiling, in a kitchen or
boiler room, as the temperature may raise to high levels.
I Do not put objects inside the unit
Make sure that no metal objects or flammable substance get
inside the camera. If used with a foreign object inside, it could
cause a fire, short-circuits or damages.
Install where the temperature range will stay between –10°C
and 50°C. (no condensation)
If water or a liquid gets inside the camera, disconnect the
power cord immediately, and consult your dealer (or a Sanyo
Authorized Service Centre). Be careful to protect the camera
from rain, sea water, etc.
I Cleaning
•
Dirt can be removed from the cabinet by wiping it with a soft
cloth. To remove stains, wipe with a soft cloth moistened
with a soft detergent solution and wrung dry, then wipe dry
with dry soft cloth.
I Be careful when handling the unit
•
Do not use benzine, thinner or other chemical product on
the cabinet, as that may cause deformation and paint
peeling. Before using a chemical cloth, make sure to read
all accompanying instructions. Make sure that no plastic or
rubber material comes in contact with the cabinet for a long
period of time, as that may cause damage or paint peeling.
To prevent damages, do not drop the camera or subject it to
strong shock or vibration.
I Install away from electric or magnetic fields
If installed close to a TV, radio transmitter, magnet, electric
motor, transformer, audio speakers the magnetic field they
generate will distort the image.
Download from Www.Somanuals.com. All Manuals Search And Download.
2
English
PARTS NAMES
1 Flange-back lock screw (LOCK)
2 Flange-back adjustment dial
2
3 Lens mount cap
The cap is installed to protect the lens mount section.
Remove the lens mount cap before installing a lens (sold separately).
4 Camera installation bracket
3
The bracket can be fixed at the top or bottom of the camera. When fixing the bracket, be sure to
use the longer screws and install the shorter screws on the opposite side to seal the openings.
1
4
CAUTION:
When installing the camera support, select a location that can support the total weight
of the camera and accessories.
1 Shorter screws: M3 x 4
2 Longer screws: M3 x 6
3 Camera mounting
screw hole:
1/4"-20 UNC
Download from Www.Somanuals.com. All Manuals Search And Download.
English
3
PARTS NAMES
5 Camera setup section
6 White balance adjustment volume (R or B)
7 Line phase adjustment volume (PHASE)
8 Lens iris adjustment volume
9
9 Lens iris output connector (LENS)
This 4-pin connector is used to send the DC control signal and power supply to an auto-iris type
lens.
8
7
6
5
F Video output connector (VIDEO OUT: BNC type)
Connect this connector to a device such as a VCR or monitor with a VIDEO IN connector.
G 24 V AC or 12 V DC input terminal (AC24V, DC12V, GND)
H Power indicator (POWER)
Comes on when the power to the camera is on.
H
I Power supply connections
F
Use a 3 wire grounded cable (22 AWG or more), and connect as shown by the illustration.
G
CAUTION:
•
To prevent camera and/or AC adaptor failure, pay close attention to polarity when making
the connections.
•
To prevent fire hazard any UL listed wire rated VW-1, should be used for the 24 V AC cable
input terminal.
Download from Www.Somanuals.com. All Manuals Search And Download.
4
English
MOUNTING THE LENS
Please use a DC type auto-iris lens (sold separately).
1
Check the lens mount
Do not use a lens if the length “L” is more than 5 mm. That may damage
the camera and prevent proper installation.
C mount type lens
L
2
1 Remove the lens mount cap from the camera.
2 Install the auto-iris lens.
CS mount type lens
Carefully align the lens mount with the camera opening, then turn the lens slowly to install it.
C mount type lens
3
To allow for flange-back adjustment, install the C-mount adaptor (option) on the lens mount,
then carefully align the lens mount with the camera opening and turn the lens slowly to install
it.
2
CS mount
type lens
3 Connect the lens plug to the lens iris output connector (LENS) on the side of the
camera.
When using lenses from other makers, the plug shape may not correspond to the terminal on
the camera. In such a case, remove the original plug and using a soldering iron, connect the
supplied lens iris plug according to the diagram. (Refer to page 6.)
Download from Www.Somanuals.com. All Manuals Search And Download.
English
5
MOUNTING THE LENS
I Pin layout
DC type lenses
Brake coil (–)
Brake coil (+)
Drive coil (+)
Drive coil (–)
2
4
1
3
1
2
3
4
I Flange-back adjustment
If the pick-up surface is not correctly positioned with relation to the lens focal point, the picture
will be out of focus (in particular when using auto-iris power zoom lenses, sold separately). If that
is the case, adjust the flange-back position as described below.
3
1 Using a + screwdriver, loosen the flange-back lock screw (M2:+).
2 Set the zoom lens to the maximum telephoto position, set the focus using the focus ring on
2
the lens.
1
3 Set the zoom lens to the maximum wide angle position, set the focus using the flange-back
adjustment dial.
4 Repeat steps 2 and 3, until the image stays in focus when changing from a telephoto shot to
a wide angle shot. When the setting is complete, tighten the flange-back lock screw.
Download from Www.Somanuals.com. All Manuals Search And Download.
6
English
CONNECTIONS
1
24 V AC connection
12 V DC connection
(A)
GND AC24V
GND AC24V
DC12V
DC12V
Figure 1
Figure 2
(Video signal connections)
: VIDEO IN
: VIDEO OUT
Basic connection for monitoring or recording
The peripheral devices (VCR, monitor, lens, etc.), AC
adaptor and cables are sold separately.
3 Insert the plug of this power cord into a wall outlet.
The POWER indicator (A) will light. Adjust the picture on
the monitor using the Brightness and Contrast controls etc.
1 Make the video signal connection between the camera
and the monitor or time lapse VCR.
I Coaxial cable type and maximum length
2 Connect the power supply.
•
•
•
Cable type RG-59U (3C-2V), 250 m maximum.
Cable type RG-6U (5C-2V), 500 m maximum.
Cable type RG-11U (7C-2V), 600 m maximum.
• If using a commercially-available 24 V AC adapter,
always be sure to connect the ground wire (18AWG or
higher) to the ground terminal. (Figure 1)
CAUTION:
• If using a 12 V DC power supply, make the connections
as shown in Figure 2.
•
The RG-59U type cable should not be run through electrical
conduits or through the air.
Note:
•
Use CCTV/Video-grade coaxial cable.
• In order to avoid any problems with the camera and the
power supply, take sufficient care to ensure that the
polarities are correct when connecting the power supply.
Download from Www.Somanuals.com. All Manuals Search And Download.
English
7
SETTINGS
I Camera setup section
No.
Settings
Position
AI
Electronic Iris (EI)/Auto iris (AI) setting
Aperture compensation setting
• SHRP (sharp)/NORM (normal)
Backlight compensation mode setting (BLC)
• MULTI (Multi)/OFF
1
2
SHRP
OFF
3
4
5
6
7
7
Backlight compensation mode setting (BLC)
• CENT (Center)/OFF
OFF
White balance setting
ATW
• MANU (manual)/ATW (auto tracing white balance)
Syncronisation (SYNC) setting
• LL (Line lock)/INT (Internal sync)
Lens iris adjustment
34
12 56
INT
—
Download from Www.Somanuals.com. All Manuals Search And Download.
8
English
SETTINGS
I Iris function setting 1
This should normally be set to the down (AI) position.
When using an auto-iris lens (for indoor/
outdoor use)
Use a manual or fixed iris lens and set the lens aperture to the
shortest F stop. Set the switch 1 to the up (EI) position.
Set the switch 1 to the down (AI) position.
CAUTION:
If conditions are outside the electronic iris operation range or
more than the maximum illumination, it will cause saturation of
the CCD. In that case, use a manual iris lens.
EI
AI
I Aperture 2
If you would like to emphasize the contours of the object, set
Note:
Please refer to the specifications for dynamic range of the
electronic iris.
the switch 2 to the up (SHRP) position.
SHRP
CAUTION:
•
The electronic iris is suitable for normal indoor use. When
the switch 1 is set to the up (EI) position, do not use an
auto-iris lens.
NORM
•
If used under fluorescent light, the image may flicker. In
such a case, change to incandescent lighting or set the
switch 1 to the down (AI) position and use an auto-iris
lens.
•
When shooting bright subjects, pay attention to the light
angle in order to avoid or minimize the smear phenomenon
effect.
Download from Www.Somanuals.com. All Manuals Search And Download.
English
9
SETTINGS
(MULTI mode: 64 sections)
I Backlight compensation setting 3 4
This camera has two different backlight
correction functions: multi-spot
MULTI CENT
photometry (MULTI) and center focus
photometry (CENT). The normal setting
(switch 3 and 4) is the down position,
but you can change the switch 3 or 4
setting in accordance with the backlight
conditions.
3
4
• MULTI mode: Use this position when applying backlight
(CENT mode)
compensation to the whole of the screen.
• CENT mode: Use this position when applying backlight
compensation to only the central portion of
the screen.
Note:
•
When using the backlight compensation function, set the
switch 3 or 4 to the up position. When not using the
function, set the switch 3 and 4 to the down (OFF)
position.
•
When MULTI mode is set, scenes with no backlighting may
appear extremely dark and the object may appear over-
exposed. If this happens, move the switch 4 to the up
(CENT) position.
Download from Www.Somanuals.com. All Manuals Search And Download.
10
English
SETTINGS
I White balance adjustment 5
I Line phase adjustment 6
Normally the switch 5 is set to the down (ATW: auto white
balance) position and the white balance is adjusted
automatically. If a manual white balance adjustment is
necessary, follow the steps below.
When using a camera switcher to connect 2 cameras or more
to one monitor, there may be a vertical roll of the images when
switched. In such a case, set as described below.
1 Set the switch 6 to the up (LL) position.
Set the switch 5 to the up (MANU) position, then adjust the
colour.
2
Switch the display on the monitor from camera 1 to camera 2.
Adjust the Line PHASE volume on camera 2 until the
•
Turn R to set the red ratio and/or B to set the blue ratio.
vertical roll of the image stops.
MANU
If more than two cameras are used, please repeat this
procedure for all the cameras.
R
WB
B
ATW
LL
INT
CAUTION:
If the vertical roll cannot be corrected by setting the Line
PHASE volume on camera 2, try setting the Line PHASE
volume on camera 1. If it still cannot be corrected, please
check that the polarity of the power cords of all connected
devices is correct.
Download from Www.Somanuals.com. All Manuals Search And Download.
English
11
SETTINGS
I Lens iris adjustment 7
If using a DC type auto-iris lens, you will need to set the
LEVEL volume when shooting in the conditions described
below.
L
H
LEVEL
L (counterclockwise): To decrease the contrast
H (clockwise): To increase the contrast
•
If shooting simultaneously in a dark room and through a
bright window.
•
•
If the subject background is extremely bright or dark.
If the brightness of the picture on the monitor is not correct.
Download from Www.Somanuals.com. All Manuals Search And Download.
12
English
TROUBLESHOOTING
Before taking the camera for repairs, please check below to make sure that the camera is used correctly. If it still does not perform
correctly, please consult your dealer or a Sanyo Authorized Service Centre.
I No picture on the monitor screen
•
•
•
•
•
Is the power turned on to all connected devices? Is the voltage correct?
Are all the signal connecting cables correctly connected?
Is the lighting sufficient?
Has the lens cap been removed?
Is the iris control correctly set?
I The picture is not clear
•
•
•
•
Is the monitor correctly adjusted?
Is the flange-back position correctly set?
Is the lens focus correctly adjusted?
Are the lens surfaces clean?
If there is dust or finger prints on the lens, the image quality will deteriorate. To clean the lens use a soft cloth or a commercially
available lens cleaning set.
SERVICE
This camera is a precision instruments and if treated with care, will provide years of satisfactory performance. However, in the
event of a problem, the owner is advised not to attempt to make repairs or open the cabinet. Servicing should always be referred to
your dealer or Sanyo Authorized Service Centre.
Download from Www.Somanuals.com. All Manuals Search And Download.
English
13
SPECIFICATIONS
I Camera:
Environmental conditions : Temperature: –10°C – +50°C
Humidity: less than 90%
Scanning system
: PAL standard
(625 TV lines, 25 frames/sec.)
: PLL 2:1 interlace
: 1/4 inch solid state image
device CCD
: 537 (H) x 597 (V)
(no condensation)
Power supply
: 24 V AC, 50 Hz/12 V – 15 V DC
Interlace
Image device
Power consumption
: Approx. 2.8 W (with AI, lens)
Approx. 2.2 W (without AI, lens)
Weight
: Approx. 280 g (without lens)
Picture elements
Effective picture elements : 500 (H) x 582 (V)
Synchronizing system
: Internal sync, Line lock
manually switchable
Resolution
: 350 TV lines horizontally, 400
TV lines vertically
SERVICE
This camera is a precision instruments and if treated with care,
will provide years of satisfactory performance. However, in the
event of a problem, the owner is advised not to attempt to
make repairs or open the cabinet. Servicing should always be
referred to your dealer or Sanyo Authorized Service Centre.
Video output level
Video S/N ratio
Minimum required
illumination
: 1.0 Vp-p/75 ohms, composite
: More than 48 dB
: Approx. 0.9 lux with a F 1.2
lens
(incandescent lighting)
Backlight compensation : MULTI/OFF switching,
CENT/OFF switching
Iris function
: Manual EI/AI switching
Electronic iris range
: 0.9 lux to 45,000 lux (F 1.2
lens)
Flange-back
White balance
Lens mount
: 12.5 mm 0.5 mm
: ATW/Manual switching
: CS mount
Download from Www.Somanuals.com. All Manuals Search And Download.
14
English
SPECIFICATIONS
I Dimensions
108
99
56
1.4
45
10.7
16
M6
28
25.8
Features and specifications are subject to change without prior notice or obligations.
Download from Www.Somanuals.com. All Manuals Search And Download.
English
15
|