PRECAUTIONS
In case of problem
Protect from humidity and dust
Do not use the camera if smoke or a strange odour comes from the
unit, or if it seems not to function correctly. Disconnect the power
cord immediately, and consult your dealer (or a Sanyo Authorized
Service Centre).
To prevent damages to the camera, do not install it where there is
greasy smoke or steam, where the dampness may get too high, or
where there is a lot of dust.
Protect from high temperatures
Do not open or modify
Do not install close to stoves, or other heat generating devices, such
as spotlights, etc., or where it could be subject to direct sunlight, as
that could cause deformation, discoloration or other damages.
Do not open the cabinet, as it may be dangerous and cause damage
to the unit. For internal settings and repairs, consult your dealer (or a
Sanyo Authorized Service Centre).
Be careful when installing close to the ceiling, in a kitchen or boiler
room, as the temperature may raise to high levels.
Do not put objects inside the unit
Install where the temperature range will stay between –10˚C and
50˚C.
(no condensation)
Make sure that no metal objects or flammable substance get inside
the camera. If used with a foreign object inside, it could cause a fire,
short-circuits or damages.
If water or a liquid gets inside the camera, disconnect the power cord
immediately, and consult your dealer (or a Sanyo Authorized Service
Centre). Be careful to protect the camera from rain, sea water, etc.
Cleaning
• Dirt can be removed from the cabinet by wiping it with a soft
cloth. To remove stains, wipe with a soft cloth moistened with a
soft detergent solution and wrung dry, then wipe dry with dry
soft cloth.
Be careful when handling the unit
To prevent damages, do not drop the camera or subject it to strong
shock or vibration.
• Do not use benzine, thinner or other chemical product on the
cabinet, as that may cause deformation and paint peeling.
Before using a chemical cloth, make sure to read all
Install away from electric or magnetic fields
accompanying instructions. Make sure that no plastic or rubber
material comes in contact with the cabinet for a long period of
time, as that may cause damage or paint peeling.
If installed close to a TV, radio transmitter, magnet, electric motor,
transformer, audio speakers the magnetic field they generate will
distort the image.
Download from Www.Somanuals.com. All Manuals Search And Download.
2
English
PARTS NAMES
1 Power indicator (POWER)
Comes on when the power to the camera is on.
5
1
2
3
2 Video output connector (VIDEO OUT: BNC type)
Connect this connector to a device such as a VCR or monitor with a VIDEO IN connector.
3 AC power cord
4
4 External sync composite video signal input connector
6
(VBS IN: BNC type)
1
2
Connect to this connector the synchronizing signal output from a synchronizing signal device or the composite
signal of a video distributor.
3
4
5 Line phase adjustment volume (LINE PHASE)
When using two cameras or more, the image on the monitor may roll vertically when switching sources. This
rolling can be minimized by turning this volume.
6 Y/C OUT connector (4 pin)
Separate Y (luminance) and C (chroma) signals are output from this terminal.
A better picture quality is obtained if the monitor or VCR is connected to this connector.
1 Y signal ground
2 C signal ground
3 Y signal: 1.0 Vp-p, 75 ohms, unbalanced, negative sync
4 C signal: 0.3 Vp-p, 75 ohms, unbalanced
Download from Www.Somanuals.com. All Manuals Search And Download.
English
3
PARTS NAMES
7 Lens mount cap
The cap is installed to protect the lens mount section.
Remove the lens mount cap before installing a lens (sold separately).
8 Flange-back adjustment screw (FLANGE BACK ADJ.)
9 Flange-back lock screw (FLANGE BACK LOCK)
F Camera installation bracket
9
7
F
8
The bracket can be fixed at the top or bottom of the camera. When fixing the bracket, be sure to use the
longer screws and install the shorter screws on the opposite side to seal the openings.
2
1
3
2
1
CAUTION:
When installing the camera support, select a location that can support the total weight of the
camera and accessories.
1 Shorter screws: M3 x 4
2 Longer screws: M3 x 6
3 Camera mounting screw
hole: 1/4"-20 UNC
Download from Www.Somanuals.com. All Manuals Search And Download.
4
English
PARTS NAMES
G Lens iris output connector (LENS)
This 4-pin connector is used to send the DC control signal and power supply to an auto-iris type lens.
H
H Camera setup section (under the cover)
G
These settings are for when using a 1/3 inch CS mount DC (without EE internal amplifier) type lens. However,
if due to installation conditions or environment the settings may need to be modified for best results (see
"SETTINGS"). To access the controls, remove the cover fixing screw, then remove the cover.
NOTE: When using a 1/2 or 2/3 inch C mount VIDEO (with EE internal amplifier) auto-iris type lens, set the
A.I. LENS switch to the VIDEO position.
Download from Www.Somanuals.com. All Manuals Search And Download.
English
5
CONCERNING AUTO-IRIS LENSES
DC type auto-iris lens
VR301
A lens without amplifier circuit that operates only on a DC power source. In general, this type of lens is
referred to as DC type coil lens or DC type non-amplifier lens.
(Set the A.I. LENS switch to the DC position.)
DC
VIDEO
VIDEO type auto-iris lens
A. I.
LENS
A lens with amplifier circuit that operates on video signal and DC power source. In general, this type of lens is
referred to as EE amplifier type lens.
ALC and LEVEL volume level controls are available on the lens for iris adjustments.
(Set the A.I. LENS switch to the VIDEO position.)
Compatible auto-iris lenses
1/3 inch Sanyo DC type lens
VCL-CS8LY: Standard angle, f= 8 mm
VCL-CS4LY: Wide angle, f= 4 mm
VIDEO type lens
Standard angle, f= 9 mm
Telephoto angle, f= 12 mm
VCL-CS2LY: Ultra-wide angle, f= 2.8 mm
Greater telephoto angle, f= 16 mm
If using a VIDEO type auto-iris lens
• Set the ALC and LEVEL controls on the lens to adjust the iris. Normally the ALC volume should be turned
all the way to Av (Average).
• Depending on the type of lens used, the lens may not perform properly. In such a case, adjust the LEVEL
volume on the lens casing to correct.
Download from Www.Somanuals.com. All Manuals Search And Download.
6
English
MOUNTING THE LENS
Please use a DC type auto-iris lens (sold separately).
1
Check the lens mount
Do not use a lens if the length “L” is more than 5 mm. That may damage the
camera and prevent proper installation.
C mount type lens
2
L
1
2
Remove the lens mount cap from the camera.
Install the auto-iris lens.
CS mount type lens
Carefully align the lens mount with the camera opening, then turn the lens slowly to install it.
C mount type lens
3
To allow for flange-back adjustment, install the C-mount adaptor (option) on the lens mount, then carefully
align the lens mount with the camera opening and turn the lens slowly to install it.
2
3
Connect the lens plug to the lens iris output connector (LENS) on the side of the camera.
CS mount
type lens
When using lenses from other makers, the plug shape may not correspond to the terminal on the camera.
In such a case, remove the original plug and using a soldering iron, connect the supplied lens iris plug
according to the diagram. (Refer to page 8.)
NOTE: When using an auto-iris lens, the supplied clamping core C must be installed on the lens wire, in
order to prevent electromagnetic interference to the other devices connected.
Download from Www.Somanuals.com. All Manuals Search And Download.
English
7
MOUNTING THE LENS
Rewiring the lens cable in the lens iris plug
1
2
Prepare the lens cable.
1
2
Cut the cable at the plug, then remove approx. 8 mm of the cable sheath and strip about 2 mm from each wire.
Install the lens iris plug.
Solder the cable to the pins following the correct pin layout (refer to the table and illustrations), then close
the plug cover.
Pin layout
DC type lenses
VIDEO type lenses
+12 V DC (50 mA max.)
Brake coil (–)
Brake coil (+)
Drive coil (+)
Drive coil (–)
1
2
3
4
2
4
1
3
2
4
1
3
Not used
Video output (1.0 Vp-p, high impedance)
Ground (for video signal and DC power)
Flange-back adjustment
If the pick-up surface is not correctly positioned with relation to the lens focal point, the picture will be out of
focus (in particular when using auto-iris power zoom lenses, sold separately). If that is the case, adjust the
flange-back position as described below.
2, 3
1
2
3
4
Using a + screwdriver, loosen the FLANGE BACK LOCK screw (M2:+).
Set the zoom lens to the maximum telephoto position, set the focus using the focus ring on the lens.
Set the zoom lens to the maximum wide angle position, set the focus using the FLANGE BACK ADJ. screw.
ADJ.
LOCK
3
1
Repeat steps 2 and 3, until the image stays in focus when changing from a telephoto shot to a wide angle shot.
When the setting is complete, tighten the FLANGE BACK LOCK screw.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
8
English
CONNECTIONS
(A)
1
2
A
B
(Video signal connections)
: VIDEO IN
2
: VIDEO OUT
3
Coaxial cable type and maximum length
• Cable type RG-59U (3C-2V), 250 m maximum.
• Cable type RG-6U (5C-2V), 500 m maximum.
• Cable type RG-11U (7C-2V), 600 m maximum.
Basic connection for monitoring or recording
The peripheral devices (VCR, monitor, lens, etc.) and cables are
sold separately.
1
2
Make the video signal connection between the camera and
the monitor or time lapse VCR.
CAUTION:
• The RG-59U type cable should not be run through electrical
conduits or through the air.
When using this unit, the supplied clamping core A and B must be
installed on the power cord and BNC cable, in order to prevent
electromagnetic interference to the other devices connected.
• Using CCTV/Video-grade coaxial cable.
3
Insert the plug of this power cord into a wall outlet.
The POWER indicator (A) will light. Adjust the picture on the
monitor using the Brightness and Contrast controls etc.
Download from Www.Somanuals.com. All Manuals Search And Download.
English
9
CONNECTIONS
(A)
1
2
A
B
(Video signal connections)
: VIDEO IN
2
: VIDEO OUT
3
CAUTION:
Connections to the camera Y/C OUT connector
The peripheral devices (VCR, monitor, lens, etc.) and cables are
• Please use a monitor with a Y/C or S-VIDEO input terminal, or a
time lapse VCR with a S-VIDEO input terminal.
sold separately.
• Use a Mini-DIN (round type, 4-pin) plug to connect to the Y/C
connector.
Never use a coaxial cable longer that 10 metres to connect the
camera to the S-VIDEO input terminal.
1
2
3
Using a coaxial cable (twin type, 75 ohms), connect the Y/C
OUT connector from the camera to the S-VIDEO input
terminal on the monitor or time lapse VCR.
When using this unit, the supplied clamping core A and B must be
installed on the power cord and BNC cable, in order to prevent
electromagnetic interference to the other devices connected.
Insert the plug of this power cord into a wall outlet.
Then, turn on the power of all the devices connected to the
camera.
The POWER indicator (A) will light. Adjust the picture on the
monitor using the Brightness and Contrast controls.
Download from Www.Somanuals.com. All Manuals Search And Download.
10
English
SETTINGS
The illustration shows the factory default settings for the switches in the camera setup section.
The camera settings are described on the assumption that a DC type auto iris lens is being used. If you are using a VIDEO type auto iris lens, be
sure to read the Note which is given.
Control name
Position
1/50 sec.
G
6
High speed electronic shutter setting
1
2
3
Electronic Iris (EI)/Auto iris (AI) setting
AI
Aperture compensation setting
(Sharp: SHRP/Normal: NOR)
SHRP
VR302
VR303
VR301
LEVEL
RED
B
L
U
E
Backlight compensation setting (BLC)
(MULT/OFF)
OFF
OFF
4
5
6
ES
2
IRIS AP BLC WB
SHRP
CENT
SC-P1
LL
E
I
1
3
MULT
M
Backlight compensation setting (BLC)
(CENT/OFF)
DC
VIDEO
ON
H-P
SC/SYNC
White balance switch (M/ATW) and colour
(R or B) adjustment volume
ATW
1
2
3
4
5
6
7
8
9
10
A. I.
LENS
MSB
LSB
A
OFF
ATW
I
NOR
OFF
External sync setting (SYNC: LL/INT)
External sync setting (SC-P1)
INT
7
8
9
F
G
adjustable
adjustable
DC
External sync horizontal adjustment (H-P)
Auto-iris lens setting (A.I. LENS), see page 6
Lens iris level adjustment
1
234567 89
F
adjustable
Download from Www.Somanuals.com. All Manuals Search And Download.
English
11
SETTINGS
High speed electronic shutter setting
Iris function setting
Normally, the speed setting switches for the high speed electronic
shutter are all set to the down (OFF) position. This sets the electronic
shutter speed to 1/50 sec. The switches can be set as indicated in
table A to select one of the 8 speeds available.
This should normally be set to the down (AI) position.
Use a manual or fixed iris lens and set the lens aperture
to the shortest F stop. Set the switch 4 (IRIS) to the up
(EI) position.
4
CAUTION:
☞ When using an auto-iris lens (for indoor/outdoor use)
• When using the high speed electronic shutter, the switch 4 must
be set to the down (AI) position.
Set the switch 4 (IRIS) to the down (AI) position.
Note:
• Using the high speed electronic shutter indoors with low lighting,
will give darker pictures. In such a case, add some lights to make
sure the lighting is sufficient. If the lighting is very bright, pay
attention to the light angle in order to avoid or minimize the
smear phenomenon effect.
• The electronic iris is suitable for normal indoor use. When the switch
4 (IRIS) is set to the up (EI) position, do not use an auto-iris lens.
• If used under fluorescent light, the image may flicker. In such a
case, change to incandescent lighting or set the switch 4 (IRIS) to
the down (AI) position and use an auto-iris lens.
Table A (switch 1 ~ 3)
• When shooting bright subjects, pay attention to the light angle in
order to avoid or minimize the smear phenomenon effect.
1
1/50
2
3
4
5
6
7
8
1/120 1/250 1/500 1/1000 1/2000 1/4000 1/10000
• If conditions are outside the electronic iris operation range or
more than the maximum illumination, it will cause saturation of
the CCD. In that case, use a manual iris lens.
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
(Unit: sec.)
Aperture
The initial setting for switch 5 is up (SHRP) so that the
contours of the object are emphasized. However, if the
contours of the object are already emphasized more
than required, set switch 5 to the down (NOR) position.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
12
English
SETTINGS
(MULTI mode: 64 sections)
Backlight compensation setting
This camera has two different backlight
compensation functions: Normally backlight
compensation switch 6 (MULT) and 7 (CENT)
are set to the down (OFF) position. Change
the backlight compensation switch settings
depending on the conditions.
6
7
• MULT mode: Use this position when applying backlight
compensation to the whole of the screen.
(CENT mode)
• CENT mode: Use this position when applying backlight
compensation to only the central portion of the
screen.
Note:
• If switches 6 and 7 are set to the up (ON) position at the same
time, the MULT setting will have priority.
• When MULT mode is set, scenes with no backlighting may appear
extremely dark and the object may appear over-exposed. If this
happens, set to CENT mode.
If using a VIDEO type auto-iris lens
• The ALC volume on the lens should be turned all the way to Av
(Average).
• If the backlight compensation function does not compensate
properly for the conditions, set using the LEVEL volume on the
lens.
Download from Www.Somanuals.com. All Manuals Search And Download.
English
13
SETTINGS
White balance adjustment
Line phase adjustment
Normally the switch 8 (WB) is set to the down (ATW: auto white
balance) position and the white balance is adjusted automatically. If a
manual white balance adjustment is necessary, follow the steps below.
When using a camera switcher to connect 2 cameras or more to one
monitor, there may be a vertical roll of the images when switched. In
such a case, set as described below.
Set the switch 8 (WB) to the up (M: manual) position, then adjust the
colour.
1
2
Set the switch 9 (SYNC) to the up (LL) position.
Switch the display on the monitor from camera 1 to camera 2.
Adjust the LINE PHASE volume on camera 2 until the vertical roll
of the image stops.
• Turn RED (VR302) to set the red ratio and/or BLUE (VR303) to set
the blue ratio.
If more than two cameras are used, please repeat this procedure
for all the cameras.
VR302
VR303
RED
B
L
U
E
8
9
Synchronization settings
The default setting is internal synchronization (INT). You can
change the power supply synchronization by moving switch 9
to the up (LL) position. Refer to “Line phase adjustment”
for details.
CAUTION:
If the vertical roll cannot be corrected by setting the LINE PHASE
volume on camera 2, try setting the LINE PHASE volume on camera
1. If it still cannot be corrected, please check that the polarity of the
power cords of all connected devices is correct.
Download from Www.Somanuals.com. All Manuals Search And Download.
14
English
SETTINGS
External sync adjustment (VBS)
Lens iris adjustment
If using a DC type auto-iris lens, you will need to set the LEVEL
(VR301) volume when shooting in the conditions described below.
1
2
Connect the VBS signal output for the other camera to the VBS
IN connector at the rear of this camera.
If the signals are not synchronized, change the sub-carrier (SC-P1)
switches as follows.
VR301
LEVEL
Setting
9-pin
OFF (down)
OFF
10-pin
OFF
Default
Set to 90˚ counterclockwise
Set to 180˚ counterclockwise
Set to 270˚ counterclockwise
ON (up)
OFF
L (counterclockwise): To decrease the contrast
ON
H (clockwise): To increase the contrast
ON
ON
• If shooting simultaneously in a dark room and through a bright
window.
• If the subject background is extremely bright or dark.
• If the brightness of the picture on the monitor is not correct.
9
10
H-P
Note:
• The sub-carrier switches let you make broad adjustments to the
sub-carrier phase. If finer adjustments are required, contact the
place of purchase.
• The type and length of the cable which is connected to the VBS
connector may cause the horizontal synchronization being out of
phase. If this happens, adjust VR304 (H-P: horizontal sync).
Download from Www.Somanuals.com. All Manuals Search And Download.
English
15
TROUBLESHOOTING
Before taking the camera for repairs, please check below to make sure that the camera is used correctly. If it still does not perform correctly, please
consult your dealer or a Sanyo Authorized Service Centre.
No picture on the monitor screen
• Is the power turned on to all connected devices? Is the voltage correct?
• Are all the signal connecting cables correctly connected?
• Is the lighting sufficient?
• Has the lens cap been removed?
• Is the lens type (DC or VIDEO) correctly selected?
Depending on the type of lens, the A. I. LENS switch must be set accordingly.
• Is the iris control correctly set?
The picture is not clear
• Is the monitor correctly adjusted?
• Is the flange-back position correctly set?
• Is the lens focus correctly adjusted?
• Are the lens surfaces clean?
If there is dust or finger prints on the lens, the image quality will deteriorate. To clean the lens use a soft cloth or a commercially available lens
cleaning set.
SERVICE
This camera is a precision instruments and if treated with care, will provide years of satisfactory performance. However, in the event of a problem,
the owner is advised not to attempt to make repairs or open the cabinet. Servicing should always be referred to your dealer or Sanyo Authorized
Service Centre.
Download from Www.Somanuals.com. All Manuals Search And Download.
16
English
SPECIFICATIONS
Camera:
Scanning system
Environmental conditions
: PAL standard
(625 TV lines, 25 frames/sec.)
: Temperature: –10˚C ~ +50˚C
Humidity: less than 90% (no condensation)
Interlace
Image device
Picture elements
Effective picture elements
Synchronizing system
: PLL 2:1 interlace
: 1/3 inch solid state image device CCD
: 795 (H) x 596 (V)
: 752 (H) x 582 (V)
: Internal sync, Line lock manually switchable,
External sync
Power supply
Power consumption
: 220 – 230 V AC ± 10% 50 Hz
: Approx. 4.0 W (with auto iris lens)
Approx. 3.0 W (without auto iris lens)
: Approx. 620 g (without lens)
Weight
Resolution
: 520 TV lines horizontally, 400 TV lines
vertically
Video output level
Y/C signal outputs
: 1.0 Vp-p/75 ohms, composite
: Y: Video; 0.7 Vp-p + sync; 0.3 Vp-p/75 ohms
C: Burst; 0.3 Vp-p/75 ohms
Video S/N ratio
: More than 48 dB
: Approx. 1.0 lux with a F 1.2 lens
Minimum required
illumination
(incandescent lighting)
Backlight compensation
: Manual ON/OFF switching, MULT/CENT
switching (Active when using an auto-iris
lens)
Iris function
: Manual EI/AI switching
Electronic iris range
Electronic shutter
: 1.0 lux to 50,000 lux (F 1.2 lens)
: 8 speeds, selectable by switches:
(1/50, 1/120, 1/250, 1/500, 1/1000,
1/2000, 1/4000, 1/10000 sec.)
Flange-back
White balance
Lens mount
: 12.5 mm ± 0.5 mm
: ATW/Manual switching
: CS mount
Download from Www.Somanuals.com. All Manuals Search And Download.
English
17
SPECIFICATIONS
Dimensions
67
136
128
1.3
54
11
1/4”–20 UNC
28
12
22
Features and specifications are subject to change without prior notice or obligations.
Download from Www.Somanuals.com. All Manuals Search And Download.
18
English
Sanyo Electric Co, Ltd.
1AC6P1P2453--
L53T5/XE(0801KPS-DSP)
Printed in Japan
Download from Www.Somanuals.com. All Manuals Search And Download.
|