SAMSUNG New DVM-Pro
User Manual (Cad mode)
English Version
2011. 07.
Download from Www.Somanuals.com. All Manuals Search And Download.
3
SAMSUNG DVM-Pro User Guide
New DVM-Pro Installation & Execution
01
ꢀ New DVM-Pro is support the Windows XP/Vista/7 32bit, 64bit.
ꢀ After installation, you need to obtain Authorization code in order to use DVM-Pro.
ꢀ New DVM-Pro is composed of ‘Cad mode’ and ‘Sales mode’
설
명
New DVM-Pro Configuration
AutoCAD 2010, 2011, 2012 based
on plug-in programs.
Cad mode
New DVM-Pro
Stand-alone system
Sales mode
Program installation & Procedure for using
Program
installation
Request the
Authorization code
Using the system
Country and language is
determined at the time
of installation. After if
you want to change the
Country and language
settings, you should
requests DVM-Pro
Country and
language Select
Coordinator.
SAMSUNG
Download from Www.Somanuals.com. All Manuals Search And Download.
4
SAMSUNG DVM-Pro User Guide
New DVM-Pro Installation & Execution
01
ꢀ When you run the New DVM-Pro, It is to choose one of two things as New DVM-Pro is composed
of ‘Cad mode’ and ‘Sales mode’
설
명
ꢀ When It need the update, Update Information displayed update information. User can update this
optionally.
Current system
information
Update system
information
‘Cad mode’, ‘Sales mode’ Run button
SAMSUNG
Download from Www.Somanuals.com. All Manuals Search And Download.
5
SAMSUNG DVM-Pro User Guide
Cad mode outline
02
ꢀ DVM-Pro Cad mode is AutoCAD plug-in program. Auto cad must be installed to use DVM-Pro cad
mode
ꢀ Designed by the cad mode, data is saved two forms(*.dwg,*.dvm).
ꢀ *.dwg is drawing file in the cad program.
설
명
ꢀ *.dvmx is DB file such as all of In/Outdoor, distribution kit, Capacity Calculation, piping check in
drawing files for the design of air conditioning systems.
ꢀ One project have two forms file. And the two files data is linked.
ꢀ When you open the DVM-Pro, Open the *.dwg file from Drawing connection icon as *.dvmx file are
automatically generated at the same time of open the DVM-Pro.
AutoCAD Installaion
AutoCAD
• AutoCAD draw file
*.dwg
DVM-Pro Cad mode
Plug-in program
• DVM-Pro data file
*.dvmx
※ Notice
ꢀ Instructions on how to use the Cad mode
→ Enable/disable command list (When you use AutoCAD command, it may not work properly in
Cad mode. because, DVM-Pro cad mode is plug-in program )
Piping, Pipe
fittings, distributor
kit etc.
Functi Enable/
Indoor
Outdoor
on
disable
Dvm command : Add/Copy indoor
CAD command : Copy , Array, Mirror
Enable
Dvm command: draw outdoor
Insert
All of command
available
Disable CAD command : Insert , Undo, Redo
CAD command : Disable
Dvm command : Delete indoor
Enable
Dvm command: Delete indoor
Delete
CAD command: Erase, Delete, Undo, Red CAD command: Erase, Undo, Redo
→ One drawing file is One building at the time of design in DVM-Pro cad mode.
→ When design in DVM-Pro cad mode, if you change the layer, *.dvm connection may be
lost.
SAMSUNG
Download from Www.Somanuals.com. All Manuals Search And Download.
6
SAMSUNG DVM-Pro User Guide
This is cad mode procedure for using when design the new
project. This procedure is not included modify procedure.
Cad mode Procedure for using
03
• Add the floor in the space management windows
• Specify the floor boundary
01
02
03
04
05
06
07
08
09
Project Registration
Space management
• When design air-conditioning drawing, need to architectural
drawings, but almost no work to modify. So, disabling a
layer of architectural drawings and change gray color to
help convenient design work.
• When add indoor, The area recognized the room and it will
be added room Automatically.
Clean architectural
drawing layers
• It can continue to draw level that all of indoor and outdoor
unit must be a connection.
• After select in in/outdoor connection windows, you can
drawing outdoor.
Add In/outdoor
In/Outdoor
connection
• Select the pit in the pit drawing window, you can draw
multiple outdoor pit.
Pit drawing
• It can draw the pipe through Draw pipe/pipe accessories,
Draw communication wires/wired remote controller.
• It can connected main pipe to multiple indoor at once,
automatically Through Draw piping automatically, Draw
drain pipe automatically
Pipe drawing
• Refrigerant pipe connection , pipe length and pipe level
difference etc is checked.
• When system check is error, modify the part of guided in
system check and check again.
System check
• Drain pipe connection is checked.
• the end of the system check, pipe diameter is placed
automatically.
Control lines
drawing
• If click on the indoor to indoor, Communication wires and
wired remote controller can connected by a line.
Piping remarks &
Piping Diagram
10
11
• Insert the pipe remarks
• Insert piping diagram by click on the list in order on the
piping diagram field of report.
Control Diagram
• Insert control diagram by click on the list in order on the
control diagram field of report.
SAMSUNG
Download from Www.Somanuals.com. All Manuals Search And Download.
7
SAMSUNG DVM-Pro User Guide
Cad mode interface
04
DVM-Pro
Menu
AutoCAD commend
• It used in DVM-Pro cad mode
• It can control all progress
functions in DVM-Pro cad mode
• It made in a palette form of Auto
cad
• Built in Auto cad interface
• More options for running the command
information can be checked in cad mode.
SAMSUNG
Download from Www.Somanuals.com. All Manuals Search And Download.
8
SAMSUNG DVM-Pro User Guide
Project
Cad mode interface
04
Possible to create the new project and start the project in cad mode palette.
New Project/Management Menu
• View and modify the project information
Possible to modify and view the
project name, customer information,
architect information in the ‘modify
the project information’ window
Possible to view save path.
It can select the local temperature. It
can be designed exact temperature for
the region.
• New project
It create a new project menu. It can
enter the project information from
same ‘project information window’.
• Open project
Select the existing project files and
open menu, when open the *.dvmx
file, open the linked * .dwg file
automatically.
• Save project
Save the current project.
• Save as the current project
Save the current project with a
different name
If this saved same path, original
*.dwg file may be lost. It should be
save new folder.
• Preferences
Set the detail using menu
SAMSUNG
Download from Www.Somanuals.com. All Manuals Search And Download.
9
SAMSUNG DVM-Pro User Guide
Project (Space management)
Cad mode interface
04
It can register and start a new project when using command palette of cad mode.
• Space management
Enter the building name.
Space management
menu
It can create/modify the each floor, floor
height, distance between ceiling.
It can create/modify the room which get
into indoor .
It can upload the Excel file which include
building, floor, room information.
• Select the building’s drawing
Select the corresponding drawing of the
selected building.
• Floor area select batch
Select the floor area continuously.
It’s progress First floor in order to roof
floor. First floor of the specified zoning
box is intended to specify the upper
floors by clicking.
• Floor area individual selection
Select the floor area.
• Room zoning
If add the room in information, it is
connected to drawing.
• Architectural drawing background processing
Change the architectural drawing color
in gray and lock layer
• Renewal
Renewal the space information.
• Space information list
It can select the building.
It can view floor, room information of building.
All of the floor information displayed Next to the building
list(ex. B0~F1) ‘B’is the basement, ‘0’is basement floors, ‘F’ is
the ground, ‘1’is the ground floors.
Floor level displayed next to the floor list.
Area information displayed next to the room list.
If click each building, floor, room, More information can be
found below.
If double click each floor and room, The drawing is zoom-in.
SAMSUNG
Download from Www.Somanuals.com. All Manuals Search And Download.
10
SAMSUNG DVM-Pro User Guide
In/Outdoor - 1
Cad mode interface
04
This interface is possible to create and manage the in/outdoor.
• Add indoor unit
After specify the area, ‘add indoor unit
window’ is open.
- If the room area already designated,
‘enter’ key no need to specify the area as
it’s open a window directly.
Possible to create & view indoor information
such as room name, area, unit load per area,
indoor number in ‘Add indoor unit’ window.
It have three menu(Indoor name, family,
type) to choose indoor model.
Indoor spec displayed indoor information
box.
Placed indoor unit in a variety of ways.
• Draw outdoor unit
a. After selected the indoor unit which
connected to outdoor unit, ‘add outdoor
unit’ window open.
b. Select the combination ratio, outdoor type,
outdoor name, by the outdoor group, series.
c. outdoor combination ratio is list-up within
the above conditions. And image, drawing,
outdoor spec is displayed.
d. connection possible or impossible of
indoor model information is displayed indoor
information box. It’s displayed in blue, red,
each. Also, possible to add, remove or
about this indoor unit.
e. After select outdoor from a list, select the
detail menu from command box and insert it.
f. if you delete the outdoor unit, it’s
outomatically turned off between the indoor.
• Add ERV
After specify the area, ‘add ERV unit’ window
is open.
- If the room area already designated,
‘enter’ key no need to specify the area as
it’s open a window directly.
Possible to check the number of ERV
through ventilation requirements, time,
personnel information .
If click each ERV indoor, More information
can be found below.
SAMSUNG
Download from Www.Somanuals.com. All Manuals Search And Download.
11
SAMSUNG DVM-Pro User Guide
In/Outdoor - 2
Cad mode interface
04
This interface is possible to create and manage in/outdoor
• Modify the indoor, ERV indoor, outdoor.
Possible to modify the each unit.
• Select the accessories
Possible to set the indoor and outdoor
accessories.
• Renewal
Space information renew as recently.
You don’t need to this menu every time.
Space information renew automatically.
But if it no work, you can renew by this
menu.
• Space information list of in/outdoor
Possible to check each building, floor, room location
information and unit location information.
It’s same the project tab information that displayed
next to building, floor, room information and model
name is displayed next to in/outdoor list.
If click each building, floor, room, More information
can be found below.
If double click each floor and room, The drawing is
zoom-in.
SAMSUNG
Download from Www.Somanuals.com. All Manuals Search And Download.
12
SAMSUNG DVM-Pro User Guide
Piping/control line
Cad mode interface
04
This interface is possible to create and manage piping/control line.
• Draw piping manually
When connect pipe using refnet joint,
• Draw piping automatically
After Select the main pipe which drawn
and select the indoor which will connect,
than enter, indoor will automatically
connect to main pipe.
• Draw pit
Select and check the deployment method
of outdoor pit in ‘draw pit’window. And
click the insertion point, and then copy
to each floor.
• Draw drain pipe manually
• Draw drain pipe automatically
After draw the main pipe, select the
indoor which will connect and click enter
key. Then indoor will connect the main
pipe.
• Insert the each pipe accessories on pipe.
If pipe accessories(refnet joint, Tee joint)
connected the pipe, pipe automatically
disconnect where the accessories enters.
If you delete the pipe accessories which
connect the pipe, pipe connect again.
• Draw vertical dewatering outlets
Select and check the deployment method
of outdoor pit in ‘ draw vertical
dewatering outlets’window. And click the
insertion point, and then copy to each
floor.
SAMSUNG
Download from Www.Somanuals.com. All Manuals Search And Download.
13
SAMSUNG DVM-Pro User Guide
Piping/control line
Cad mode interface
04
This interface is possible to create and manage the piping/control line.
• Pipe accessories
a. when select the outdoor unit, accessories
activation that connectable.
• System check
present the problem. It make users to modify
it.
System check can determine the suitability of
design and can be minimized design errors by
user.
• Draw piping and drain annotation/change the
annotation’s direction.
After finished the system check, piping
annotation draw to center of each pipe with
a choice of all/zoning option.
If use the change the annotation’s direction
menu and click the piping annotation, it will
change.
• Draw pit annotation
After select the direction of pit and click the
enter key, annotation pit inserted.
• Communication wires & controller
If you select this, you can show only
communication wires & controller layers.
• Draw communication wires
Darwing from the pit or free space, then
click indoor and next indoor. When selection
finished, click the enter key.
• Draw wired remote controller manually
Clicking from the indoor, then when
selection finished, click the remote location
and enter key. When this finished, remote
control icon will insert.
SAMSUNG
Download from Www.Somanuals.com. All Manuals Search And Download.
14
SAMSUNG DVM-Pro User Guide
Report
Cad mode interface
04
This interface is possible to create and manage the piping/control line.
• Report
Select the report list and insert the report in
drawing.
• Pipe diagram
Insert the pipe diagram in order to the list
of pipe diagram menu.
- Draw layer of floor
- Arrange indoor & outdoor unit
- Draw vertical dewatering outlets
- Draw drain pipe
- Draw annotation of outdoor unit’s pipe
- Draw remarks
• Power/communication/controller diagram
Insert the power/communication/controller
diagram in order to the list of diagram
menu.
- Draw layer of floor
- Arrange indoor & outdoor unit
- Draw wired remote controller manually
- Draw indoor’s power wiring
- Draw outdoor’s power wiring
- draw outdoor’s communication
- Draw interface module
- Draw unit of controller solution
- Draw remarks
SAMSUNG
Download from Www.Somanuals.com. All Manuals Search And Download.
15
SAMSUNG DVM-Pro User Guide
(1) Project registration
Step-by-step description of the design
05
• project info.
• Check and edit.
01
01-1
02
• Assignment
(drawing file)
• New project
• It can create new *.dvm file.
• When select the icon, asks whether to
save as when you open the DVM-Pro
program, *.dvm new file is already open.
• Select open method the drawing
• All open drawing is display in this
window. And if you choose one, that
one is open and connect.
• Open where architectural
drawing select window.
• Actice drawing of all open drawing is connect the project building.
SAMSUNG
Download from Www.Somanuals.com. All Manuals Search And Download.
16
SAMSUNG DVM-Pro User Guide
(1) Project register and save
Step-by-step description of the design
05
01 02 03
01.Open the project
• when DVM and DWG file is saved same folder and you open the DVM file, DWG file open
automatically. If it’s saved no same folder and you open the DVM file, DWG file no open. So
you should use Assignment(drawing file) menu to open the DWG file.
02. Save the project
save the new project first time : when specify the path to the DVM file and save, DWG file save
same path with DVM file from the original position.
*if you save in same folder which saved recently, open DWG file path is same save path so
DWG file will be over written. Then original file may be missing.
save after saved : it save same path and over written.
03.Save as project
this menu is save again in other path.
SAMSUNG
Download from Www.Somanuals.com. All Manuals Search And Download.
17
SAMSUNG DVM-Pro User Guide
(1) Management (building/floor/room)
Step-by-step description of the design
05
• Method of add room
- There is pre-and enter all
of room information in
management (room area,
unit load per area etc)
proceed and add the room
when add the indoor. And
if you want to delete the
room, you should delete in
only space management
window.
• Space management
01
02
03
04
• Hold the block down which same add
the room number from same line on the
floor.
02
• Choose the name which need to delete
and click this button. Then that room
will be delete.
SAMSUNG
Download from Www.Somanuals.com. All Manuals Search And Download.
18
SAMSUNG DVM-Pro User Guide
(2) Management (building/floor/room)-1
(3) Process the grayscale, lock layers
Step-by-step description of the design
05
• Process the grayscale,
lock layers
02
01
• Zoning(all floor)
• There is zoning(each floor)
menu also. You can zoning 1
by 1.
04
03
06
05
SAMSUNG
Download from Www.Somanuals.com. All Manuals Search And Download.
19
SAMSUNG DVM-Pro User Guide
(4) Add in/outdoor-1
Step-by-step description of the design
05
When you add the indoor, you can add the room. In/outdoor information and room area is displayed interface left side and
room information will be utilized by after reports.
01
03
02
• Zoning(room)
• Enter the indoor unit and
room information
04
When add the indoor, model
name is different, depending
on the model type. You
05
should
be
designed
to
distinguish between model
type and model type of each
indoor unit can be connected
only as outdoor.
06
- If Add the indoor unit in the same manner as above, room name connect the room
area in drawing. Then indoor insert in that room area.
SAMSUNG
Download from Www.Somanuals.com. All Manuals Search And Download.
20
SAMSUNG DVM-Pro User Guide
(4) Add in/outdoor-2
Step-by-step description of the design
05
The placement of the indoor unit method is three method ( 1) center 2) user deployment 3) copy ) indoor unit and room can
copy and it displayed “in/outdoor information’ window in real-time
When insert the block, Ctrl key is redirect and Tab key is point conversion.
Copy/move
• Copy the indoor unit and room on the second floor
• Add the indoor unit on the first floor
• Add the CAC and FJM indoor unit
CAC, FJM can be added in the same method.
Wall mounted, stand type are insert 1 by 1.
when insert the wall mounted indoor,
attaches to the wall.
1way cassette indoor insert 1 by 1. and after
enter the distance from the wall, attaches to
the wall.
SAMSUNG
Download from Www.Somanuals.com. All Manuals Search And Download.
21
SAMSUNG DVM-Pro User Guide
(4) Add in/outdoor-3
Step-by-step description of the design
05
This is explain of name block.
• Model name
ND0834HXB1
• Model name
RD540HHXH2
• Zone information
The first line is capacity,
The second line is model
name to the rest.
This number mean connection of in/outdoor.
Connection indoor and outdoor are same number. So
you can see the connection.
In/outdoor name.
SAMSUNG
Download from Www.Somanuals.com. All Manuals Search And Download.
22
SAMSUNG DVM-Pro User Guide
(5) Connect in/outdoor-1
Step-by-step description of the design
05
If you can continue to draw level, all of indoor connect the outdoor. And you can draw the outdoor after select in ‘in/out
connect’ window.
• Unable to connect indoor
02
01
04
03
• Connect the FJM in/outdoor
Connect the same method.
SAMSUNG
Download from Www.Somanuals.com. All Manuals Search And Download.
23
SAMSUNG DVM-Pro User Guide
(5) Connect in/outdoor-2
Step-by-step description of the design
05
If you select the in/outdoor which will connect, In/outdoor connection of CAC is connect simply.
01
02
03
SAMSUNG
Download from Www.Somanuals.com. All Manuals Search And Download.
24
SAMSUNG DVM-Pro User Guide
(6) Draw pit
Step-by-step description of the design
05
After setting the number of columns and line Pit, click on the location of the drawing. Pit draw by outdoor and if you put the
mouse near the pit, you can see a connection outdoor image when you draw the piping.
02
01
03
• Speed command :
you can execute the menu
without click. When you
04
enter
this
command,
menu execute.
• Copy the pit where other
floors.
SAMSUNG
Download from Www.Somanuals.com. All Manuals Search And Download.
25
SAMSUNG DVM-Pro User Guide
(7) Draw piping-1
Step-by-step description of the design
05
This is connection the piping. Recognize the connection point automatically without click the direct connection point.
• When you enter this command, menu execute.
• All of the unit have connection point when mouse comes
close. If click near piping, it connect this point automatically.
Also, pipe accessories are same.
• if you put the mouse near the pit, you can see a connection
outdoor image, outdoor name, model name when you draw
the piping.
01
02
If you put the
mouse near the
outdoor unit, you
can see connection
which look like ‘x’.
• When you draw distribution pipe, drawing like behind capture
and Enter. Than you can choose direction and you will see the
refnet joint direction which before choose.
02
01
03
SAMSUNG
Download from Www.Somanuals.com. All Manuals Search And Download.
26
SAMSUNG DVM-Pro User Guide
(7) Draw piping-2
Step-by-step description of the design
05
It’s explain to draw the piping. Auto/manual pipe is available. You can various forms of draw the pipe.
You can draw through draw piping manually. It have draw piping automatically menu. You can connect indoor to main piping.
• When you enter this command,
menu execute.
• When you draw distribution
pipe,
drawing
like
behind
Select the
capture and Enter. Than you can
choose direction and you will
see the refnet joint direction
which before choose.
Click the
main piping
indoor units to
automatically
connect
After click the Enter key, select the
04
05
direction of refnet joint.
Connect the last indoor / Select the pipe leaving
SAMSUNG
Download from Www.Somanuals.com. All Manuals Search And Download.
27
SAMSUNG DVM-Pro User Guide
(7) Draw piping-3
Step-by-step description of the design
05
It’s explain to draw the piping. Auto/manual pipe is available. You can various forms of draw the pipe.
Also you can draw piping accessories.
When insert the block, Ctrl key is redirect and Tab key is point conversion.
01
If pipe accessories(refnet joint,
Tee joint) connected the pipe,
pipe automatically disconnect
where the accessories enters. And
you can choose direction of refnet
joint through use Ctrl
If you delete the pipe accessories
which connect the pipe, pipe
connect again.
• Tee and cap draw the same
method.
02
• Header, MCU draw the same
method.
• When draw the piping from piping
accessories, if you don’t want to
go to a different point, click the
ctrl key.
01
SAMSUNG
Download from Www.Somanuals.com. All Manuals Search And Download.
28
SAMSUNG DVM-Pro User Guide
(7) Draw piping-4
Step-by-step description of the design
05
It’s explain to draw the drain piping, Auto/manual pipe is available. You can various forms of draw the pipe.
It have draw drain piping, draw Tee, draw cap. And It have draw drain piping automatically menu. You can connect indoor to
main drain piping.
• When you enter this command, menu execute.
01
03
02
04
After enter key
05
After enter key
03
04
Select the
indoor units
to
automatically
connect
SAMSUNG
Download from Www.Somanuals.com. All Manuals Search And Download.
29
SAMSUNG DVM-Pro User Guide
(7) Draw piping-5
Step-by-step description of the design
05
It’s explain to draw the drain piping, Auto/manual pipe is available. You can various forms of draw the pipe.
• If you delete the Tee and drain which connected the Tee, returns to original state of
the drain piping. And Elbow is delete that include the deleted drain piping.
• If Tee joint connected the pipe, pipe automatically disconnect where the accessories
enters.
• If you put the mouse near the unit, you can see connection which look like ‘x’. When
click the ‘x’, drain piping will appear to block and the.
• When draw the drain piping from drain piping, if drain piping draw from drain piping,
Tee draw automatically.
01
02
03
Put on the indoor unit
block and click the ‘x’
01
02
SAMSUNG
Download from Www.Somanuals.com. All Manuals Search And Download.
30
SAMSUNG DVM-Pro User Guide
(7) Draw piping-6
Step-by-step description of the design
05
If Draw dewatering outlets and draw vertical dewatering outlets. draw vertical dewatering outlet’s number is same, same
number is same location of the other floor. Than this information used diagram in report. Tab.
01
If you selected same number
when you insert the drain pit, all
same number pit is one line in
piping diagram.
02
Select the insert point
Draw the dewatering outlets: select the insert point
SAMSUNG
Download from Www.Somanuals.com. All Manuals Search And Download.
31
SAMSUNG DVM-Pro User Guide
(8) System check-1
Step-by-step description of the design
05
Refrigerant pipe connection , pipe length and pipe level difference etc is checked. And When system check is error, modify
the part of guided in system check and check again. Drain pipe connection is checked. the end of the system check, pipe
diameter is placed automatically.
02
• Select the outdoor for system check
03
01
04
• When system check is error
• Double click after check the
error massage.
05
• Zoom-in the error location.
SAMSUNG
Download from Www.Somanuals.com. All Manuals Search And Download.
32
SAMSUNG DVM-Pro User Guide
(8) System check-2
Step-by-step description of the design
05
Pass the drawing check, test a variety of check list. If it have a problem, display part of the problem and explain the cause of
the problem. Also, finish the check, pipe diameter is placed automatically.
01
02
• Check the drawing and edit.
• After the resolution, do the
system check again until It
should not be problem.
SAMSUNG
Download from Www.Somanuals.com. All Manuals Search And Download.
33
SAMSUNG DVM-Pro User Guide
(9) Controller wire-1
Step-by-step description of the design
05
Select the communication wires/wired remote controller, draw the communication wires/wired remote controller.
• When you enter this command, menu execute.
• Select check box the piping/piping accessories or communication
wires/remote controller, selection layer is active. So, you can
distinction .
refrigerant
Drain piping
04
02
06
01
Put on the near side, all of
unit outside of indoor is
possible to connect.
03
05
07
• Click the connection indoor in order and
then when you enter, complet the
connection.
SAMSUNG
Download from Www.Somanuals.com. All Manuals Search And Download.
34
SAMSUNG DVM-Pro User Guide
(9) Controller wire-2
Step-by-step description of the design
05
Select the communication wires/wired remote controller, draw the communication wires/wired remote controller.
• When you enter this command, menu execute.
• Select check box the piping/piping accessories or communication
wires/remote controller, selection layer is active. So, you can
distinction .
• Click the connection indoor in order and then when you enter,
complet the connection.
Put on the near side, all of
unit outside of indoor is
possible to connect.
03
04
01
02
SAMSUNG
Download from Www.Somanuals.com. All Manuals Search And Download.
35
SAMSUNG DVM-Pro User Guide
Step-by-step description of the design (10) Piping remarks & Piping Diagram-1
05
Design the piping remarks and insert to drawing.
Click the piping diagram list in order. then Design the piping diagram.
02
03
01
• Repeat the order of outdoor and indoor which
include the outdoor. You can insert this block to
click the rocation.
• If dewatering outlets is not connect the drain
piping, ddwatering outlets is displayed with block.
• You can change the direction of piping to use Ctrl
key
01
When you Click and enter ,
03
02
Display the piping remarks.
Drain pit Connection by clicking.
03
02
Specifies the arrow keys to
move pipe height.
01
SAMSUNG
Download from Www.Somanuals.com. All Manuals Search And Download.
36
SAMSUNG DVM-Pro User Guide
Step-by-step description of the design (10) Piping remarks & Piping Diagram-2
05
Click the piping diagram list in order. then Design the piping diagram.
Click
the
indoor
Click the direction
03
01
02
Enter
01
Click the insert point
SAMSUNG
Download from Www.Somanuals.com. All Manuals Search And Download.
37
SAMSUNG DVM-Pro User Guide
(11) control Diagram-1
Step-by-step description of the design
05
Click the piping diagram list in order. then Design the control diagram.
02
01
• You can change the direction of the remote
controller. it depend upon the direction of
the mouse.
• It displayed such as indoor group of the
plans.
03
01
When you click and
enter, display the power
wire information.
02
03
Drain pit connection by clicking
03
02
Specifies the arrow keys to
move pipe height.
01
SAMSUNG
Download from Www.Somanuals.com. All Manuals Search And Download.
38
SAMSUNG DVM-Pro User Guide
(11) control Diagram-2
Step-by-step description of the design
05
Click the piping diagram list in order. then Design the control diagram.
Click the direction
03
Click the
outdoor
01
02
Enter
Click the direction
03
Click the
outdoor
01
02
Enter
Click
the
insert
point
01
02
Enter
03
Click the insert point
Click the direction
SAMSUNG
Download from Www.Somanuals.com. All Manuals Search And Download.
|