FREE JOINT MULTI AIR CONDITIONER
INDOOR UNIT
MH026FNCA
MH035FNCA
MH052FNCA
MH026FECA
MH035FECA
MH052FECA
OUTDOOR UNIT
MH050FXCA2A
MH080FXCA4A
Manualꢀ
SERVICEꢀ
AIR CONDITIONER
THE FEATURE OF PRODUCT
■
■
Multi Inverter(Free Joint Multi) Series
– Variable Indoor Unit Combination(Free Joint Multi)
– Multi Inverter(Free Joint Multi) Series delivers
comfort to 2~4 rooms with a Single Outdoor Unit
– Smart & Low noise outdoor units in any condition.
Energy Saving
– High Efficiency DC inverter and BLDC Comp.
– Smart Inverter Control algorithm.
–
TBR Sine-Wave Compressor & Sine Wave Controller.
■
■
Convenient Installation
– 485 non Polarity / Auto addressing
– Easy checking system condition by 7-segment
Space Saving & Environmental Friendly
– Compact & Light Outdoor Unit
– Slim and Quiet Indoor Units
Refer to the service manual in the GSPN(see the rear cover) for the more information.
Download from Www.Somanuals.com. All Manuals Search And Download.
Contents
..............................................................................................................................
................................................................................................................
9. Troubleshooting
9-1
9-1
9-1 Items to be checked first
...............................................................................................
9-2 Checking and Testing operations
9-2
.......................................................................................................
9-3 Fault Diagnosis by Symptom
9-12
9-18
...................................................................................................................................
9-4 PCB Inspection
.......................................................................................................
10. Reference for Installation
10-1
10-1
10-3
10-5
10-7
10-8
10-9
....................................................................................................
.................................................................................
10-1 Selecting Area for Installation
10-2 Connecting Up and Purging the Circuit
..............................................................................................................................
10-3 Refrigerant Refill
.................................................................................................................
................................................................................................................
..............................................................................................................
10-4 Refrigerant Adjustment
10-5 Flare Nut Fixing Torque
10-6 "Pump down" Procedure
...............................................................................................................
.................................................................................................................
.....................................................................................................
11. Reference Information
11-1
11-1
11-3
11-5
11-5
11-6
11-9
11-1 Index for Model Name
11-2 Refrigerating Cycle Diagram
11-3 Pressure & Capacity mark
.........................................................................................................
..............
11-4 The abbreviated technology words & the definition of technology terms
...................................................................................................................
11-5 Q & A for Non-trouble
...............................................................................................
11-6 Common sense of refrigeration
Download from Www.Somanuals.com. All Manuals Search And Download.
1. Precautions
1-1 Installing the air conditioner
●
Users should not install the air conditioner by themselves.
Ask the dealer or authorized company to install the air conditioner except the window-type air conditioner in U.S.A and Canada.
If you don’t install the air conditioner properly, it may cause a fire, a water leakage or an electric shock.
You must install the air conditioner according to the national wiring regulations and safety regulations.
Install the indoor unit higher than 8.2ft(2.5m) from the floor to avoid the injury caused by the operation of the fan.
(except the window-type air conditioner)
●
●
●
●
●
The manufacturer is not responsible for any accidents or injury caused by an incorrect installation.
When installing the built-in type air conditioner, keep all electric cables such as the power cable and the connection cord in pipes,
ducts, or cable channels to protect them from the danger of impact or any other incidents.
More than 2 indoor units should be installed when you use Free Joint Multi air conditioner.
MH050FXCA2A
●
●
- MH052FNCA and MH052FECA indoor unit cannot be connected to the MH050FXCA2A outdoor unit.
1-2 Power supply and circuit breaker
●
If the power cord of the air conditioner is damaged, it must be replaced by the manufacturer or a qualified person in order to
avoid a hazard.
●
The air conditioner must be plugged into an independent circuit if applicable or connect the power cable to the auxiliary circuit
breaker.
An all pole disconnection from the power supply must be incorporated in the fixed wiring with a contact opening of >0.12inch(mm).
Do not extend an electric cord to the air conditioner.
●
●
The air conditioner must be plugged in after you complete the installation.
1-3 During operation
●
●
●
Do not repair the air conditioner at your discretion.
It is recommended to contact a service center directly.
Never spill any kind of liquid on the air conditioner.
If this happens, turn off the air conditioner and contact an authorized service center.
Do not insert anything between the airflow blades to prevent damage of the inner fan and consequent injury.
Keep children away from the air conditioner.
●
●
●
Do not place any obstacles in front of the air conditioner.
Do not spray any kind of liquid into the indoor unit. If this happens, turn off the air conditioner and contact a service center.
Make sure that the air conditioner is well ventilated at all times:
Do not place a cloth or other materials over it.
●
●
Remove the batteries if you don’t use the remote control for a long time. (If applicable)
Use the remote control within 23ft(7m) from the indoor unit. (If applicable)
Samsung Electronics
1-1
Download from Www.Somanuals.com. All Manuals Search And Download.
1-4 Disposing of the unit
●
●
Before throwing out the air conditioner, remove the batteries from the remote control.
When you dispose of the air conditioner, consult your dealer. If pipes are removed incorrectly, refrigerant may blow out and
cause air pollution. When it contacts with your skin, it can cause skin injury.
●
The package of the air conditioner should be recycled or disposed of properly for environmental reasons.
1-5 Others
●
●
●
●
Never store or load the air conditioner upside down or sideways to prevent the damage to the compressor.
Young children or infirm persons should be always supervised when they use the air conditioner.
Max current is measured according to IEC standard for safety.
Current is measured according to ISO standard for energy efficiency.
1-2
Samsung Electronics
Download from Www.Somanuals.com. All Manuals Search And Download.
2. Product Specifications
2-1 The Feature of Product
■ Multi Inverter(Free Joint Multi) Series delivers comfort to 2~4 rooms with a Single Outdoor Unit.
■ Inverter for High Efficiency Operation.
Thanks to inverter control, efficiency of operation of the outdoor unit is enhanced depending on the number of indoor units
operated and the temperature setting.
When only one indoor unit is used, power is saved, resulting in a smaller electricity bill. When all indoor units are used,
high-power operation achieves comfort quickly in all rooms.
■ Installation of indoor units on different floors is possible.
■ Convenient Installation
Auto addressing option : Automated checking of pipe connection.(Refer to the installation manual for detail)
■ Space saving & Environmental Friendly
• Compact & light outdoor unit
• Slim and quiet indoor units
• Pipe size reduction
• Ozone friendly Refrigerant(R410A)
• Lead Free controller.
■ Reliability
• Installation possibilities(Length/Height)
• Convenient installation(485 non polarity/auto-addressing)
• Intelligent control/network
• Easy checking system condition by 7-segment
■ Smart & Low Noise outdoor units in any condition
• TBR/Sine-Wave Controller/Noise Reduction Control/Dual Felt etc.
• Felt Structure : New felt has selected to reduce the noise coming out of the compressor.
Double layered felt structure absorbs noise by two times and felt is also covering top of the compressor to
reduce the noise even more.
Samsung Electronics
2-1
Download from Www.Somanuals.com. All Manuals Search And Download.
2-2 Product Specifications
Model
MH026FNCA
MH035FNCA
Item
INDOOR UNIT
Type
Wall-mounted
9,000
Wall-mounted
12,000
13,000
-
Cooling
Heating
Dehumidifying
Btu/hr
10,000
-
|/h
Cooling
Perfor-
8.31
9.54
Air Volume
m3/min
mance
Heating
8.56
9.93
Cooling
32
36ꢀ
Noise
dB
ø,V,Hz
W
Heating
32
36ꢀ
Power
1,208~230,60
30
1,208~230,60
35
Cooling
Power Consumption
Heating
30
35
Power
Cooling
0.18
0.19
Operating Current
Heating
A
0.18
0.19
mm
inch
825x285x189
32x11x7.4
7.8kgꢀ
825x285x189
32x11x7.4
7.8kgꢀ
WxHxD
Outer Dimension
Weight
kg
Liquid
Gas
OD(inch)xL(ft)
OD(inch)xL(ft)
DxL(mm)
ø1/4
ø1/4
Refrigerant Pipe
Drain Hose
Size
ø3/8x24.6
ø18x535
Cross-fan
Resin/steel
27ꢀ
ø3/8x24.6
ø18x535
Cross-fan
Resin/steel
27ꢀ
Type
Motor
Blower
Type
Rated Output
W
Heat Exchanger
2ROW 14STEP
EEV
2ROW 14STEP
EEV
Refrigerant Control Unit
2-2
Samsung Electronics
Download from Www.Somanuals.com. All Manuals Search And Download.
Product Specifications(cont.)
Model
MH052FNCA
Item
INDOOR UNIT
Wall-mounted
18,000
Type
Cooling
Heating
Dehumidifying
Btu/hr
19,000
|/h
-
Cooling
Perfor-
13.21
Air Volume
m3/min
mance
Heating
14.22
Cooling
40
Noise
dB
ø,V,Hz
W
Heating
40
Power
1,208~230,60
50
Cooling
Power Consumption
Heating
50
Power
Cooling
0.30
Operating Current
Heating
A
0.30
mm
inch
1,065x298x128
42x12x8.6
13
WxHxD
Outer Dimension
Weight
kg
Liquid
Gas
OD(inch)xL(ft)
OD(inch)xL(ft)
DxL(mm)
ø1/4x24.6
ø1/2x24.6
ø18x600
Cross-fan
Resin/steel
40ꢀ
Refrigerant Pipe
Drain Hose
Size
Type
Motor
Blower
Type
Rated Output
W
Heat Exchanger
2ROW 16STEP
EEV
Refrigerant Control Unit
Samsung Electronics
2-3
Download from Www.Somanuals.com. All Manuals Search And Download.
Product Specifications(cont.)
Model
MH026FECA
MH035FECA
MH052FECA
Item
INDOOR UNIT
Slim Duct
12,000
Type
Slim Duct
9,000
Slim Duct
18,000
Cooling
Heating
Cooling
Btu/hr
10,000
8.6
13,000
19,000
9.8
13.6
Air Volume
Perfor-
mance
m3/min
Heating
9.0
10.3
14.2
Cooling
31
32
39ꢀ
Noise
dB
ø,V,Hz
W
Heating
31
32
39ꢀ
Power
1,208~230,60
76
1,208~230,60
76
1,208~230,60
150
Cooling
Power Consumption
Heating
76
76
150
Power
Cooling
0.35
0.35
0.69
Operating Current
Heating
A
0.35
0.35
0.69
mm
inch
900x199x600
35.4x7.8X23.6
26
900x199x600
38.2x7.1x15.4
26
1,100x199x600
1,100x199x600
31
WxHxD
Outer Dimension
Weight
kg
Liquid
Gas
OD(inch)xL(ft)
OD(inch)xL(ft)
ø1/4x24.6
ø3/8x24.6
Sirocco fan
Resin/steel
47ꢀ
ø1/4x24.6
ø3/8x24.6
Sirocco fan
Resin/steel
47ꢀ
ø1/4x24.6
ø1/2x24.6
Sirocco fan
Resin/steel
53ꢀ
Refrigerant Pipe
Size
Type
Motor
Blower
Type
Rated Output
W
Heat Exchanger
2ROW 12STEP
EEV
2ROW 12STEP
EEV
2ROW 12STEP
EEV
Refrigerant Control Unit
2-4
Samsung Electronics
Download from Www.Somanuals.com. All Manuals Search And Download.
Product Specifications(cont.)
/QFGNꢀ
/*ꢀꢀꢀ(:&#ꢁ$ꢀ
/*ꢀꢂꢀ(:%#ꢃ#ꢀ
+VGOꢀ
176&114ꢄ70+6ꢀ
(TGGꢀ,QKPVꢀ/WNVKꢀ
6[RGꢀ
(TGGꢀ,QKPVꢀ/WNVKꢀ
ꢂꢃꢄꢅꢅ`ꢄꢆꢃꢇꢅꢅꢀ
ꢂꢃꢄꢅꢅ`ꢌꢄꢃꢂꢅꢅꢀ
ꢉꢀꢁꢂꢀ
%QQNKPIꢀ
ꢈꢃꢂꢅꢅ`ꢉꢄꢃꢊꢅꢅꢀ
$VWꢁJTꢀ
%CRCEKV[ꢀ
*GCVKPIꢀ
ꢊꢃꢂꢅꢅ`ꢉꢇꢃꢍꢅꢅꢀ
2GTHQTꢋꢀ
ꢉ
#KTꢀ8QNWOGꢀ
OCPEGꢀ
O ꢁOKPꢀ
ꢃꢄꢁꢃꢀ
%QQNKPIꢀ
ꢇꢍꢀ
ꢂꢌꢀ
0QKUGꢀ
F$ꢀ
Óꢃ8ꢃ*\ꢀ
9ꢀ
*GCVKPIꢀ
ꢂꢄꢀ
ꢂꢌꢀ
2QYGTꢀ
ꢄꢃꢌꢅꢆ`ꢌꢉꢅꢃꢈꢅꢀ
ꢇꢇꢅ`ꢄꢃꢊꢆꢅꢀ
ꢉꢂꢅ`ꢄꢃꢍꢅꢅꢀ
ꢌꢐꢂ`ꢆꢐꢂꢀ
ꢄꢃꢌꢅꢆ`ꢌꢉꢅꢃꢈꢅꢀ
%QQNKPIꢀ
ꢂꢆꢅ`ꢉꢃꢇꢌꢅꢀ
2QYGTꢀ%QPUWORVKQPꢀ
2QYGTꢀ
ꢎ1WVFQQTꢀ
1PN[ꢏꢀ
*GCVKPIꢀ
ꢈꢌꢅ`ꢉꢃꢄꢍꢅꢀ
%QQNKPIꢀ
ꢌꢐꢊ`ꢄꢂꢐꢊꢀ
1RGTCVKPIꢀ%WTTGPVꢀ
#ꢀ
*GCVKPIꢀ
ꢌꢐꢅ`ꢍꢐꢄꢀ
ꢌꢐꢆ`ꢄꢇꢐꢈꢀ
(WUGꢀ%CRCEKV[ꢀ
#ꢀ
KPEJꢀ
MIꢀ
ꢌꢅꢀ
ꢉꢅꢀ
&KOGPUKQPꢀ
9GKIJVꢀ
9Z*Z&ꢀ
ꢉꢄꢐꢄZꢌꢄꢐꢈZꢄꢄꢐꢌꢀ
ꢂꢉꢀ
ꢉꢇꢐꢈZꢉꢄꢐꢇZꢄꢌꢐꢌꢀ
5K\Gꢀ
ꢈꢂꢀ
6[RGꢀ
6YKPꢀ4QVCT[ꢀ
)ꢆ6ꢌꢅꢅ(7#'9ꢀ
6YKPꢀ4QVCT[ꢀ
/QFGNꢀ0COGꢀ
/QVQTꢀ
)ꢆ6ꢌꢈꢅ(7#'9ꢀ
6[RGꢀ
$.&%ꢀ2GTOCPGPVꢀOCIPGVKEꢀ/QVQTꢀ
$.&%ꢀ2GTOCPGPVꢀOCIPGVKEꢀ/QVQTꢀ
%QOꢋꢀ
RTGUUQTꢀ
6[RGꢀ
21'ꢀ
ꢊꢅꢅꢀ
21'ꢀ
ꢊꢅꢅꢀ
.WDTKECPVꢀ1KNꢀ
2TQVGEVKQPꢀ&GXKEGꢀ
$NQYGTꢀ
%CRCEKV[ꢀ
EEꢀ
1.2ꢀ
1.2ꢀ
6[RGꢀ
2TQRGNNGTꢀ
Óꢇꢌꢅꢀ
2TQRGNNGTꢀ
Óꢇꢈꢅꢀ
(CPꢀ/QVQTꢀ
ꢑꢀ
5K\Gꢀ
1&ꢎOOꢏZ.ꢎOꢏꢀ
$NQYGTꢀ
/QVQTꢀ
4CVGFꢀ1WVRWVꢀ
9ꢀ
ꢃꢄꢀ
ꢅꢆꢇꢀ
*GCVꢀ'ZEJCPIGTꢀ
ꢌ419ꢀꢌꢆ56'2ꢀ
''8ꢀ
ꢌ419ꢉꢈ56'2ꢀ
''8ꢀ
4GHTKIGTCPVꢀ%QPVTQNꢀ&GXKEGꢀ
%JCTIKPIꢀ4GHTKIGTCPVꢎ4ꢇꢄꢅ#ꢏꢀ
Q\ꢀ
ꢊꢅꢐꢂꢂꢀ
ꢍꢆꢐꢊꢊꢀ
Samsung Electronics
2-5
Download from Www.Somanuals.com. All Manuals Search And Download.
2-3 Accessory and Option Specifications
2-3-1 Indoor Unit Accessories
■ MH✳✳✳FNCA
+VGO
&GUETKRVKQPU
%QFGꢅ0Qꢆ
3 6;
4GOCTM
&$ꢍꢊꢋꢅꢌꢆꢂꢄ$
ꢎ/*ꢅꢌꢈ(0%#ꢁ/*ꢅꢉꢂ(0%#ꢏ
+PUVCNNCVKQPꢀ2NCVG
ꢎ2NCVGꢋ*CPIGTꢏ
ꢄ
&$ꢍꢅꢋꢅꢌꢊꢉꢆ#
ꢎ/*ꢅꢂꢌ(0%#ꢏ
4GOQVGꢀ%QPVTQN
7UGTꢀ/CPWCN
&$ꢍꢉꢋꢅꢉꢅꢄꢌ3
ꢄ
ꢄ
+PFQQT
7PKV
5
+10
%6
47
+0
56
5
0'4
19
'5
+10
%%
47
+056
&'
#.
07
/#
.
751
4
2'
0+
<+1
47
+56
5
¨'
7
64
+05
&'
#.
07
/#
0
6+1
+5#
7
6+.
&
'.
07
/#
)
70
'+5
09
5#
%*
#7
$4
)'
QPGT
QPFKVK
#KT
%
4QQO
ꢅV[RG
OC
5
RNKV
5RNWV
UKUVG
EQ
OÃUVK
FQ FQ
G
RCTCV
KEKQPC
EQPF
#KTG
C
KGPVK
GT COD
CF
W
PKV´ 5G
R
VQTG
F
CTKC
VKRQ
5
RNKV
K\KQPC
%QPF
QPCFQ
PFKEK
CT EQ
&$ꢍꢆꢋꢌꢍꢄꢈꢌ#
NJ
Q
FG
#RCTG
UÃRC
TÃ
G
FG V[R
VKUGWT
%NKOC
G
NCI
KOCCP
WOMN
NVG TC
)GVGK
05
6+1
7%
64
5
+05
4
0'
'5
+10
%%
47
19
+056
4
2'
&'
#.
07
/#
.
751
+
+10
7<
+564
¨'5
7
64
+05
&'
#.
07
/#
0
6+1
5#
7
6+.+
&
'.
07
/#
)
70
'+5
09
*5#
7%
4#
)'$
KQPGT
%
QPFKV
#KT
4QQO
ꢅV[RG
5RNWV
5
RNKV
KEQ
OÃUV
UKUVG
OC
FQ FQ
CF
DKGPVK
GT CO
VKRQ
PFKEK
QPCFQ
G
RCTCV
KEKQPC
PKV´ 5G
#KTG
C
EQPF
W
F
G
CTKC
R
E
Q
5
RNKV
VQTG
K\KQPC
%QPF
F
CT
NJQ
#RCTG
%NKOC
NVG TC
UÃRC
TÃ
G
RG
FG V[
VKUGWT
CI
KOCCPN
WOMN
)GVGK
+PUVCNNCVKQPꢀ/CPWCN
&$ꢍꢆꢋꢌꢍꢄꢈꢉ#
ꢄ
6JGꢀFGUKIPꢀCPFꢀUJCRGꢀECPꢀDGꢀEJCPIGFꢀCEEQTFKPIꢀVQꢀVJGꢀOQFGNꢐ
2-6
Samsung Electronics
Download from Www.Somanuals.com. All Manuals Search And Download.
Product Specifications
Indoor Unit Accessories(cont.)
■ MH✳✳✳FECA
Item
Descriptions
Code-No.
Q'TY
Remark
S
ON
CTI
RU
'S
NER
I
NST
INST
OW
IO
NES
CC
RU
DE
AL
NU
MA
SO
L'U
I
PER
ON
UZI
ISTR
ÕES
Ç
RU
INST
DE
AL
NU
MA
N
TIO
ISA
TIL
D'U
EL
NU
MA
N
G
EISU
NW
HSA
UC
RA
GEB
oner
onditi
Air
C
Room
-type
Splut
ma
S
plit
co
ad un
siste
mésti
e
parat
do do
er am
ciona
ità Se
plit
Aire
a
condi
bienti
onado
d
e
'aria
p
on
S
tore
iziona
Cond
tipo
dici
d
ar
c
lho
Apare
Clima
lte ra
sépa
ré
e
de typ
tiseur
lag
e
imaan
umkl
Getei
User
Manual
DB98-29159A
1
S
ION
CT
RU
INST
R'S
NE
OW
ES
ION
C
UC
INSTR
L'U
PER
DE
AL
NU
MA
SO
I
ION
UZ
ISTR
ÕES
UÇ
TR
INS
DE
AL
NU
MA
N
TIO
SA
TILI
D'U
EL
NU
MA
N
G
EISU
NW
SA
CH
AU
BR
GE
ioner
C
ondit
Air
Room
-type
Splut
ma
S
plit
co
mésti
do do
iciona
siste
parate
Aire
a
cond
ad
u
nità Se
r
am
bienti
d
e
'aria pe
tore
iziona
Cond
tipo
S
plit
ndici
onado
d
ar
c
o
lho
ré
Apare
Clima
lte ra
sépa
lag
e
de typ
tiseur
e
imaan
umkl
Getei
Installation Manual
Pattern Sheet
DB98-29160A
1
1
1
1
1
8
DB97-03906A/B
DB72-00143D
Insulation-Install Outlet
Insulation-Install Inlet
Drain Hose Joint
DB72-00143E
DB94-00758A
DB63-00237A
Indoor
Unit
Rubber
(Grommet Hanger)
Insulation-Drain Out
Insulation-Out
DB62-03439H
DB62-03439J
DB62-03440H
1
2
1
Insulation-Drain In
✳ The design and shape can be changed according to the model.
Samsung Electronics
2-7
Download from Www.Somanuals.com. All Manuals Search And Download.
Product Specifications
Indoor Unit Accessories(cont.)
■ MH✳✳✳FECA(cont.)
Item
Descriptions
Code-No.
Q'TY
Remark
Cable-tie
DB65-10088C
8
Indoor
Unit
Drain Pipe Holder
DB90-02064A
2
✳ The design and shape can be changed according to the model.
2-8
Samsung Electronics
Download from Www.Somanuals.com. All Manuals Search And Download.
Product Specifications
2-3-2 Outdoor Unit Accessories
■ MH050FXCA2A/MH080FXCA4A
+VGO
&GUETKRVKQPU
%QFGꢅ0Qꢆ
3 6;
4GOCTM
&TCKPꢀ2NWIꢀ1WV
&$ꢈꢊꢋꢌꢅꢅꢄꢄ#
ꢄ
6TCPUOKVVGTꢀRQYGTꢀECDNG
ꢎ#UU [ꢀ%QPPGEVQTꢀ9KTGꢋ&%ꢀ2QYGTꢏ
&$ꢍꢉꢋꢅꢂꢅꢂꢍ#
&$ꢊꢉꢋꢌꢅꢄꢉꢇ#
&$ꢍꢆꢋꢌꢍꢄꢈꢇ#
&$ꢍꢆꢋꢌꢍꢄꢈꢄ#
&$ꢈꢉꢋꢇꢇꢉꢊꢂ#
ꢄ
ꢇ
ꢄ
ꢄ
4WDDGTꢀ.GI
+PUVCNNCVKQPꢀ/CPWCN
5GTXKEGꢀ/CPWCN
0KRRNGꢀ%QPPGEVQT
1WVFQQT
7PKV
05
6+1
7%
64
+05
4
5
0'
'5
+10
%%
47
+056
19
&'
#.
07
/#
51
.
7
+
2'4
+10
7<
+564
¨'5
7
64
+05
&'
#.
07
/#
0
6+1
+5#
7
6+.
&
'.
07
/#
)
+5
70
9'
#0
*5
7%
4#
)'$
0
)
57
9'+
#0
*5
7%
4#
)'$
0
)
+57
9'
#0
*5
7%
4#
)'$
KQPGT
%
QPFKV
#KT
4QQO
ꢅV[RG
5RNWV
5
RNKV
KEQ
UKUVG
OC
KV´ 5G
RNKV
OÃUV
FQ FQ
EKQPC
EQPFK
G
RCTCV
#KTG
C
DKGPVK
R
GT CO
CF WP
VQTG
F
CTKC
VKRQ
TÃ
5
K\KQPC
#RCTG
QPCFQ
%QPF
PFKEK
CT EQ
NJQ FG
G
UÃRC
G
FG V[R
VKUGWT
%NKOC
CI
G
KOCCPN
WOMN
NVG TC
)GVGK
NCI
KOCCP
WOMN
NVG TC
)GVGK
05
6+1
7%
64
4
5
+05
0'
'5
+10
19
%
7%
+0564
&'
#.
07
/#
751
4
0+ 2'
.
<+1
47
+56
¨'
5
7
64
+05
&'
&
#.
07
/#
0
+1
#6
.+5
76+
'.
07
/#
0
)
)
+57
9'
#0
*5
7%
4#
)'$
0
'+57
09
5#
%*
#7
$4
)'
0
57
)
9'+
#0
*5
7%
4#
)'$
KQPGT
%
QPFKV
#KT
4QQO
ꢅV[RG
5RNWV
5
RNKV
UKUVG
OC
ÃUVKEQ
FQ FQO
RCTCVG
PKV´ 5G
RNKV
KEKQPC
C
EQPF
CF
W
#KTG
DKGPVK
GT CO
CTKC
CT
R
VQTG
F
VKRQ
TÃ
5
K\KQPC
QPCFQ
%QPF
FKEK
E
QP
NJQ
F
G
#RCTG
UÃRC
NCI
G
FG V[R
VKUGWT
%NKOC
G
KOCCP
WOMN
NVG TC
)GVGK
CIG
KOCCPN
WOMN
NVG TC
)GVGK
ꢄ
ꢎ/*ꢅꢆꢅ(:%#ꢇ#ꢏ
6JGꢀFGUKIPꢀCPFꢀUJCRGꢀECPꢀDGꢀEJCPIGFꢀCEEQTFKPIꢀVQꢀVJGꢀOQFGNꢐ
Samsung Electronics
2-9
Download from Www.Somanuals.com. All Manuals Search And Download.
Product Specifications
2-3-3 Transmitter Unit Accessories
Item
Descriptions
Code-No.
Q'TY
Remark
Transmitter
(Ass'y PCB-DVM Plus I/M)
DB9303568A
(MIM-B13)
1
Transmitter Power cable
(Wire Harness-DC Source)
DB39-00378E
(MIM-B13)
1
1
1
Transmitter communication cable
(Connect Wire-COM)
DB39-00253B
(MIM-B13)
Transmitter
Case
DB61-00450B
(MIM-B13)
(Case-Relay PCB Out)
Cable-tie
DB65-10088B
3
1
NS
TIO
UC
TR
INS
R'S
NE
OW
ES
ION
CC
RU
INST
DE
AL
NU
MA
'USO
R
L
PE
NI
ZIO
RU
IST
S
ÕE
UÇ
TR
INS
DE
AL
NU
MA
N
TIO
ISA
TIL
D'U
EL
NU
MA
N
N
G
G
G
EISU
NW
HSA
UC
RA
GEB
EISU
NW
HSA
UC
RA
GEB
N
EISU
NW
ioner
HSA
UC
RA
Air
GEB
C
ondit
Room
type
Splut-
ma
ità Se
plit
S
plit
co
mésti
do do
ciona
siste
parate
condi
ad un
Aire
a
r
am
bienti
tore
iziona
Cond
d
e
'aria pe
tipo
S
c
o
ndici
onado
lho
d
ar
ré
Apare
Clima
lte ra
sépa
lag
e
e
de typ
tiseur
umkl
imaan
DB98-25776A
(MIM-B13)
e
imaan
Getei
lte ra
lag
umkl
Getei
Installation Manual
✳ The design and shape can be changed according to the model.
2-10
Samsung Electronics
Download from Www.Somanuals.com. All Manuals Search And Download.
ꢀꢁꢂꢃHECJIAJPꢂ=J@ꢂꢃ@FQOPIAJPOꢀ
ꢀꢄꢅꢂ"NNKNꢂIK@Aꢂ=J@ꢂ?DA?GꢂIAPDK@ꢀ
ꢀꢄꢅꢄꢅꢂ&J@KKNꢂ2JEPꢀ
/*ꢀ
(0%#ꢀ
+PFKECVQTUꢀ
12'4#6+10ꢀ
6+/'4ꢀ
674$1ꢀ
&GUETKRVKQPꢀ
/CKPꢄ%JGEMKPIꢄ2QKPVꢀ
+PFQQTꢀWPKVꢀTQQOꢀVGORGTCVWTGꢀUGPUQTꢀGTTQTꢀ
ꢎQRGPꢀQTꢀUJQTVꢏꢀꢀ
ꢋꢀ
+PFQQTꢀWPKVꢀJGCVꢀGZEJCPIGTꢀVGORGTCVWTGꢀUGPUQTꢀGTTQTꢀ
ꢎQRGPꢀQTꢀUJQTVꢏꢀꢀ
ꢋꢀ
ꢋꢀ
+PFQQTꢀHCPꢀOQVQTꢀOCNHWPEVKQPꢀ
1RVKQPꢀ5GVVKPIꢀ
1RVKQPꢀ5GVVKPIꢀ
''241/ꢀGTTQTꢀꢀ
1RVKQPꢀGTTQTꢀ
ꢎQRVKQPꢀYCUPꢀVꢀUGVꢀWRꢀQTꢀQRVKQPꢀFCVCꢀGTTQTꢏꢀꢀ
4GOQVGꢀ%QPVTQNꢀQPꢁQHHꢀ
1WVFQQTꢀ7PKVꢀ2QYGTꢀ4GUGVꢀ
1WVFQQTꢀWPKVꢀGTTQTꢀ
Samsung Electronics
3-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Alignment and Adjustments
■ MH✳✳✳FECA
The error indicated on the LED display of Indoor unit
Indicators
Concealed Type
Abnormal conditions
Operating
Blue
Red
Standard Type
Power reset
Displayed on
appropriate indoor unit
which is operating
Error of temperature sensor in indoor unit(OPEN/SHORT)
Displayed on
appropriate indoor unit
which is operating
Error of heat exchanger sensor in indoor unit
Error of heat exchanger OUT sensor in indoor unit
Error of outlet temperature sensor in indoor unit
(OPEN/SHORT): For heat pump models only
Error of mixed operation
Displayed on
appropriate indoor unit
which is operating
Displayed on outdoor
unit
Error of outdoor temperature sensor
Error of COND sensor
Error of DISCHARGE sensor
1. No communication for 2 minutes between indoor unit
and outdoor unit (communication error for more than
2 minutes)
1. Error of indoor unit :
Displayed on the
indoor unit regardless
of operation
2. Indoor unit receiving the communication error from
outdoor unit
2. Error of outdoor unit :
Displayed on the
indoor unit which is
operating
3. Outdoor unit tracking 3 minutes error
4. When sending the communication error from outdoor
unit the mismatching of the communication numbers
and installed numbers after completion of tracking.
(communication error for more than 2 minutes)
Self-diagnostic error
(including the indoor unit not detected)
Displayed on
appropriate indoor unit
which is operating
Displayed on outdoor
unit
1. Error of electronic expansion valve close
2. Error of electronic expansion valve open
3. Breakaway of EVA OUT sensor
4. Breakaway of EVA IN sensor
: On
: Flickering
: Off
◆ If you turn off the air conditioner when the LED is flickering, the LED is also turned off.
◆ If you re-operate the air conditioner, it operates normally at first, then detect an error again.
Samsung Electronics
3-2ꢀ
Download from Www.Somanuals.com. All Manuals Search And Download.
Alignment and Adjustments
■ MH✳✳✳FECA(cont.)
The error indicated on the LED display of Indoor unit
Indicators
Concealed Type
Abnormal conditions
Operating
Blue
Red
Standard Type
Displayed on appropriate
indoor unit which is
operating
Displayed on outdoor
unit
5. Breakaway of COND MID sensor
6. 2nd detection of refrigerant completely leak
7. 2nd detection of high temperature COND
8. 2nd detection of high temperature DISCHARGE
9. COMP DOWN due to 2nd detection of low pressure
switch
10. Error of reverse phase
11. Compressor down due to 6th detection of freezing
12. Self-diagnosis of condensation sensor (G8, G9)
13. Compressor down due to condensation ratio control
Error of float switch
Error of setting option switches for optional accessories
EEPROM error
EEPROM option error
: On
: Flickering
: Off
◆ If you turn off the air conditioner when the LED is flickering, the LED is also turned off.
◆ If you re-operate the air conditioner, it operates normally at first, then detect an error again.
3-3ꢀ
Samsung Electronics
Download from Www.Somanuals.com. All Manuals Search And Download.
Alignment and Adjustments
3-1-2 Outdoor Unit
Display
REMARK
EXPLANATION(The error indicated on the PCB display of outdoor unit)
Check electrical connection
and setting
Communication error(indoor unable to receive data)
Outdoor unit communication error
(Abnormal data from indoor unit over 60 packet)
Check electrical connection
and setting
Indoor unit room temperature sensor error (Open/Short)
Indoor unit heat exchanger in temperature sensor error (Open/Short)
Indoor unit heat exchanger out temperature sensor error (Open/Short)
Indoor unit sensor error-Evaporator pipe in sensor - Self diagnosis
Indoor unit sensor error-Evaporator pipe out sensor - Self diagnosis
Indoor Unit FAN Error
More than two indoor units cool and heat simultaneously
Indoor Unit EEPROM Error
Indoor Unit EEPROM Option Error
Failure of pipe check operation
Check electrical connection
and setting
No pipe check operation check
- occasion : try to operation after the installation through auto addressing
mode without pipe check operation.
Check setting
Check electrical connection
and setting
The number of Indoor unit mismatched
Check electrical connection
and setting
Communication error between the outdoor and indoor unit
Outdoor communication error between main PCB and sub PCB
Outside temperature sensor error(Short/Open)
- Error level: over 4.9V(-50˚C) under 0.4V(93˚C)
Condenser temperature sensor error(Short/Open)
- Error level: over 4.9V(-50˚C) under 0.4V(93˚C)
Outdoor unit sensor error - Condenser out sensor(Short/Open) - Self diagnosis
Compressor Discharge temperature sensor error
Compressor discharge sensor detached - Self diagnosis
Compressor OLP sensor error (Short/Open)
- Error condition : outdoor temperature under -20˚C
- Error level : over 4.95V(-30˚C) under 0.5V(151˚C)
Samsung Electronics
3-4ꢀ
Download from Www.Somanuals.com. All Manuals Search And Download.
Alignment and Adjustments
Outdoor Unit(cont.)
Display
REMARK
EXPLANATION(The error indicated on the PCB display of outdoor unit)
check pipe length, indoor
unit filter, refrigerant leakage/
charge and service port
Outdoor unit freezing(Compressor stop)
check pipe length, refrigerant
leakage/charge
Outdoor unit overload - Safety control(Compressor stop)
check pipe length, refrigerant
leakage/charge
Outdoor unit high discharge temperature - Safety control
(Compressor stop)
Outdoor unit EEV open (Stopped indoor unit s) -Self diagnosis
Outdoor unit EEV open (operating indoor unit s) -Self diagnosis
High temperature(over 30˚C) of outdoor as heating mode
Low temperature(under -10˚C) of outdoor as cooling mode
Outdoor Fan Error
Check electrical connection
Communication cable mismatched between indoor and outdoor unit
Inverter compressor starting failure (5 times)
Compressor trip by input current control mode (PFC over current)
Compressor trip by OLP temperature control mode
DC peak error (IPM Over Current)
Compressor Limit Error
DC link Voltage error (under 150V, over 410V)
Abnormal compressor running
(Compressor Rotation Error)
Current sensor error
DC link Voltage sensor error
OTP Error
Inverter micom zero-crossing error
NO GAS error(self diagnosis)
Piping(gas leak)
3-5ꢀ
Samsung Electronics
Download from Www.Somanuals.com. All Manuals Search And Download.
3-2 Setting Option Setup Method
ex) Option No. :
Step 1 : Enter the Option Setup mode.
1st
Take out the batteries of remote control.
2nd
Press the temperature
insert the battery again.
button simultaneously and
3rd
Make sure the remocon display shown as
.
Step 2 : Enter the Option Setup mode and select your option according to the following procedure.
Feature
Display
1
Setting Option SEG1.
Push the
button to set the display panel to
.
Every time you push the button, the display panel reads
. . .
repeatedly.
2
Setting Option SEG2.
Push the
Every time you push the button, the display panel reads
. . .
button to set the display panel to
.
repeatedly.
3
4
3
Change it into the set display of Option SEG3 and SEG4
with the button.
1,4
2,5
Setting Option SEG3.
Push the button to set the display panel to
Every time you push the button, the display panel reads
.
. . .
repeatedly.
5
Setting Option SEG4.
Push the
Every time you push the button, the display panel reads
. . .
button to set the display panel to
.
repeatedly.
Samsung Electronics
3-6ꢀ
Download from Www.Somanuals.com. All Manuals Search And Download.
Alignment and Adjustments
Feature
Display
6
7
Change it into the set display of Option SEG5 and SEG6
with the
button.
Setting Option SEG5.
Push the button to set the display panel to
Every time you push the button, the display panel reads
.
. . .
repeatedly.
8
Setting Option SEG6.
Push the
Every time you push the button, the display panel reads
. . .
button to set the display panel to
.
repeatedly.
6,9
9
Change it into the set display of Option SEG7 and SEG8
with the button.
7,10
8,11
10
Setting Option SEG7.
Push the button to set the display panel to
Every time you push the button, the display panel reads
.
. . .
repeatedly.
11
Setting Option SEG8.
Push the
Every time you push the button, the display panel reads
. . .
button to set the display panel to
.
repeatedly.
12
13
Change it into the set display of Option SEG9 and SEG10
with the button.
12
13
14
Setting Option SEG9.
Push the button to set the display panel to
Every time you push the button, the display panel reads
.
. . .
repeatedly.
14
Setting Option SEG10.
Push the
Every time you push the button, the display panel reads
. . .
button to set the display panel to
.
repeatedly.
3-7ꢀ
Samsung Electronics
Download from Www.Somanuals.com. All Manuals Search And Download.
Alignment and Adjustments
Step 3 : Upon completion of the selection, check you made right selections.
Whenever you press the button, the set Option will be displayed.
Step 4 : Pressing the ON/OFF button (
)
When pressing the operation ON/OFF key with the direction of remote controller for unit, the sound "Ding" is heard and the
OPERATION LED lamp is flickering at the same time, then the input of option is completed. (If the "ding" sound isn't heard,
try again pressing the ON/OFF button.)
Step 5 : Unit operation test-run
First, Remove the battery from the remote controller.
Second, Re-insert the battery into the remote controller.
Third, Press ON/OFF (
) key with the direction of remote controller for set.
• Error Mode
1st
If all lamps of indoor unit are flickering, Plug out, plug in power plug again and press ON/OFF key to retry.
2nd
If the unit is not working properly or all lamps are continuously flickering after setting the option code, see if the
correct option code is set up for its model.
Samsung Electronics
3-8ꢀ
Download from Www.Somanuals.com. All Manuals Search And Download.
TECHNICAL BULLETIN
Technical Bulletins are produced to provide information not contained in the manuals or to update currently
published technical information on the Samsung line of Mini splits
This bulletin is on :
Option Code Procedure for MH Neo Forte
Know this
The Option codes shown in the Service manual have been REVISED
The correct option code sequence, and recommended procedure is shown below
Option codes are required if ALL of the Indicator lights on the Indoor unit are blinking, the PCB has
been replaced or the Indoor and Outdoor units are not communicating
Symbol
MH026FNCA
ON TIMER OFF TIMER
MH035FNCA
ON TIMER OFF TIMER
MH052FNCA
ON TIMER OFF TIMER
Auto
Cool
Dry
2
4
2
2
7
0
4
2
0
0
1
0
0
0
0
0
2
4
2
2
7
0
6
2
0
0
1
0
0
0
0
0
2
4
2
2
6
0
9
2
0
0
1
0
0
0
0
0
Fan
Heat
1
A
0
0
4
D
0
0
8
F
0
0
Step 1 Make sure the Indoor unit is turned OFF. At the Outside unit turn off the power supply,
wait for 1 minute for the Outdoor unit to completely power down, then re-apply power to the system
Step 2 Remove the batteries from the remote, wait 10 secs then hold down BOTH the UP & DOWN temperature
arrow buttons. While holding down the buttons re-insert batteries
Step 3 An arrow should appear next to the Auto mode graphic, with 00 and the
ON timer icon on the screen If no display appears repeat Step 2
Step 5 Using the DOWN arrow key, press it the correct number of times to scroll
the first digit in the code, display will change 0, through 9, A, B, C, D, E, F
Once the first digit is programmed, then use the UP arrow key to program
the second digit using the same method
Step 6 Press the mode button, the arrow will move down to the next symbol, enter
the digits required. Repeat until ALL the code above is entered
Step 7 Press the MODE button again, the OFF timer icon will display, DO NOT
enter the code again, press the MODE button 5 more times to return to the
ON timer icon, then check the code entered against the above. Once
checked use the MODE button to scroll through the OFF timer section
Step 8 Point the remote at the Indoor unit, and press the POWER button 5 times
to inject the code into the unit. Unit Ding's to show code has been accepted
Remove batteries, wait 10 secs and re-insert batteries normally
Step 9 Do not turn Indoor unit on using remote, instead go to the Outdoor unit
Press the K2 Button THREE times to get the unit operating in the test mode
Once the Indoor unit is making Condensate
Press the K3 Button to take the unit out of the Test mode
Restart unit using the remote, set to the required temperature and mode
Tech Bulletin - Option Codes FJM MH FNCA Neo Forte
#1
Jun-08
Download from Www.Somanuals.com. All Manuals Search And Download.
Alignment and Adjustments
■ Table of the option code
MODEL
OPTION CODE
MH026FNCA
027402-14221A-200001-300000
MH035FNCA
MH052FNCA
027402-16224d-200001-300000
026402-19228F-200001-300000
'ZVGTPCNꢄ5VCVKEꢄ2TGUUWTGꢀ
ꢉꢆꢀꢀ
ꢁꢆꢀꢇ5VCPFCTFꢈꢀ
ꢊꢆꢀꢀ
ꢃꢆꢀꢀ
ꢇOO#Sꢈꢀ
ꢅꢄꢂꢌꢅꢄꢋꢄꢇꢅꢀꢅ&ꢀ
ꢋꢌꢅꢅꢅꢅꢄꢋꢉꢅꢅꢅꢅꢅꢀ
ꢅꢄꢂꢌꢅꢄꢋꢄꢇꢅꢌꢆ(ꢀ
ꢋꢌꢅꢅꢅꢅꢄꢋꢉꢅꢅꢅꢅꢅꢀ
ꢅꢄꢂꢌꢅꢄꢋꢄꢇꢅꢉꢂꢅꢀ
ꢋꢌꢅꢅꢅꢅꢄꢋꢉꢅꢅꢅꢅꢅꢀ
ꢅꢄꢂꢌꢅꢆꢋꢄꢇꢅꢉ)ꢂꢀ
ꢋꢌꢅꢅꢅꢅꢄꢋꢉꢅꢅꢅꢅꢅꢀ
/*ꢅꢌꢈ('%#ꢀ
ꢅꢄꢂꢌꢅꢄꢋꢄꢈꢅꢌꢂ)ꢀ
ꢋꢌꢅꢅꢅꢅꢄꢋꢉꢅꢅꢅꢅꢅꢀ
ꢅꢄꢂꢌꢅꢄꢋꢄꢈꢅꢆꢉꢇꢀ
ꢋꢌꢅꢅꢅꢅꢄꢋꢉꢅꢅꢅꢅꢅꢀ
ꢅꢄꢂꢌꢅꢆꢋꢄꢈꢅꢅꢊꢆꢀ
ꢋꢌꢅꢅꢅꢅꢄꢋꢉꢅꢅꢅꢅꢅꢀ
ꢅꢄꢂꢌꢅꢉꢋꢄꢈꢅꢆ&(ꢀ
ꢋꢌꢅꢅꢅꢅꢄꢋꢉꢅꢅꢅꢅꢅꢀ
/*ꢅꢉꢂ('%#ꢀ
ꢅꢄꢄꢌꢌꢇꢋꢄꢍꢇ1&ꢂꢀ
ꢋꢌꢅꢅꢅꢅꢄꢋꢉꢅꢅꢅꢅꢅꢀ
ꢅꢄꢄꢌꢌꢇꢋꢄꢍꢇ2'ꢈꢀ
ꢋꢌꢅꢅꢅꢅꢄꢋꢉꢅꢅꢅꢅꢅꢀ
ꢅꢄꢄꢌꢌꢇꢋꢄꢍꢇ1(ꢊꢀ
ꢋꢌꢅꢅꢅꢅꢄꢋꢉꢅꢅꢅꢅꢅꢀ
ꢅꢄꢄꢌꢌꢇꢋꢄꢍꢇꢌꢅꢆꢀ
ꢋꢌꢅꢅꢅꢅꢄꢋꢉꢅꢅꢅꢅꢅꢀ
/*ꢅꢂꢌ('%#ꢀ
ꢒꢌOO#SꢀKUꢀVJGꢀDCUKEꢀOQFGNꢀQHꢀVJKUꢀRTQFWEVꢐꢀ
ꢀ4GHGTꢀVQꢀVJGꢀVCDNGꢀCDQXGꢀFGRGPFKPIꢀQPꢀVJGꢀKPUVCNNCVKQPꢀGPXKTQPOGPVꢐꢀ
3-9ꢀ
Samsung Electronics
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Disassembly and Reassembly
■ Necessary Tools
Item
Remark
+SCREW DRIVER
MONKEY SPANNER
Samsung Electronics
4-1
Download from Www.Somanuals.com. All Manuals Search And Download.
4-1 Indoor Unit
Stop operation of the air conditioner and remove the power cord before repairing the unit.
4-1-1 MH026FNCA/MH035FNCA/MH052FNCA
No
Parts
Procedure
Remark
1) Stop the air conditioner operation and
shut off the main power.
1
Front Grille
2) Open the Front Grille by pulling right and
left sides of the hook.
3) Loosen 1 of the right screw and detach
the Terminal Cover.
4) Detach the thermistor from the Front
Grille.
5) Loosen 3 fixing screws of Front Grille.
4-2
Samsung Electronics
Download from Www.Somanuals.com. All Manuals Search And Download.
Disassembly and Reassembly
No
Parts
Procedure
Remark
6) Unlock 3 hooks to fix Panel Front and
Tray Drain.
7) Unlock 3 hooks to fix Panel Front and
Back-Body.
1) Take all the connector of PCB upper
side out. (Inclusion Power Cord)
Control-In
(Main PCB)
2
2) Detach the outdoor unit connection
wirefrom the Terminal Block.
3) Loosen 4 fixing screws of Ass’y Control-In.
Tray Drain
1) Pull Tray Drain out from the Back Body.
3
Samsung Electronics
4-3
Download from Www.Somanuals.com. All Manuals Search And Download.
Disassembly and Reassembly
No
Parts
Procedure
Remark
1) Loosen 2 fixing earth screws of right side.
2) Detach the Connection Pipe.
4
Heat Exchanger
3) Detach the Holder Pipe at the rear side.
4) Loosen the 4 fixing screws of right and
left side.
5) Lifting the Heat Exchanger up a little to
push the up side for separation from the
indoor unit.
1) Loosen the fixing screw.
2) Detach the Fan Motor from the Fan.
3) Detach the Fan From the left Holder
Bearing.
5
Fan Motor
&
Cross Fan
4-4
Samsung Electronics
Download from Www.Somanuals.com. All Manuals Search And Download.
Disassembly and Reassembly
4-1-2 MH026FECA/MH035FECA
No
Parts
Procedure
Remark
1) Disassemble the Cabinet Top Motor.
- Unscrew 8 screws
1
Motor
&
Blower
2) Disassemble 2 Cover Blower Uppers.
- After unscrewing 2 screws
- Disassemble the Cover Blower Upper
with pushing its hook.
3) Disassemble the Cover Control.
- Unscrew 2 screws
Samsung Electronics
4-5
Download from Www.Somanuals.com. All Manuals Search And Download.
Disassembly and Reassembly
No
Parts
Procedure
Remark
4) Disassemble Motor Wires connected to
the inside of PCB and connected to the
Capacitor.
5) Disassemble the Motor earth wire
connected to the Partition.
- Unscrew a screw
6) Disassemble the band Motor for fixing
the Motor.
- Unscrew 2 screws
7) After disassembling the Motor and Blower
for the set, disassemble the Blower by
use of 3mm wrench.
4-6
Samsung Electronics
Download from Www.Somanuals.com. All Manuals Search And Download.
Disassembly and Reassembly
No
Parts
Procedure
Remark
1) Disassemble the Cabinet Top Evap.
- Unscrew 11 screws
2
Drain Pan
2) Disassemble the Bracket Outlet Sub that
fixes the Drain Pan equipped on the front
of the set.
- Unscrew 6 screws
3) Disassemble the Drain Cushion from the
set.
Samsung Electronics
4-7
Download from Www.Somanuals.com. All Manuals Search And Download.
Disassembly and Reassembly
No
Parts
Procedure
Remark
✳
The Evaporator should be disassembled
after disassembling the Cover Control
1-3) and the Drain Pan 2-1), 2-2), 2-3).
3
Evaporator
1) Disassemble the Cover Pipe that fixes
the high/low pressure Pipe.
- Unscrew 2 screws
2) Disassemble the refrigerant temperature
sensor, Inlet air temperature sensor, and
EEV wire that connected to the inside of
PCB.
3) Disassemble the Support Evap. LF that
fixes the Evaporator.
- Unscrew 2 screws
4) Disassemble the Support Evap RH.
- Unscrew 2 screws
4-8
Samsung Electronics
Download from Www.Somanuals.com. All Manuals Search And Download.
Disassembly and Reassembly
No
Parts
Procedure
Remark
5) Disassemble the Evaporator form the set.
4
Control In
✳
The Control In should be disassembled
after disassembling the Cover Control
1-3).
1) Disassemble all Control Wires connected
to the inside of PCB.
2) In case of disassembling the PCB
separately, disassemble the PCB from
the case with pushing the hook after
unscrewing the screw.
- Unscrew 1 screw
3) In case of disassembling the Capacitor
separately, disassemble the Capacitor
from the Case.
4) In case of disassembling the Case
Control, disassemble the Case Control
from the set after unscrewing the screw
connected to the direction of Blower.
- Disassemble if after disassembling the
Cabinet Top Motor 1-1).
Samsung Electronics
4-9
Download from Www.Somanuals.com. All Manuals Search And Download.
Disassembly and Reassembly
No
Parts
Procedure
Remark
5) In case of disassembling the Trans
Power, unscrew the screw fixing on the
Case.
✳ Disassemble if after disassembling the
case PCB 4-4).
5
1) Disassemble the Bracket Outlet
Bracket Outlet
assembled on the Cabinet.
- Unscrew 10 screws
4-10
Samsung Electronics
Download from Www.Somanuals.com. All Manuals Search And Download.
Disassembly and Reassembly
4-1-3 MH052FECA
No
Parts
Procedure
Remark
1) Pull out the Filter as picture 1 or picture 2.
1
Filter
2) If it is necessary, after disassembling
8 indicating screws, detach the
Bracket Filter.
Samsung Electronics
4-11
Download from Www.Somanuals.com. All Manuals Search And Download.
Disassembly and Reassembly
No
Parts
Procedure
Remark
3) If the Cabinet-Top Motor is assembled on
the side of the set, the procedure of
disassembling the Filter is just as the
above.
1) After disassembling 13 indicating screws,
detach Ass’y Cabinet-Top Motor.
Blower
&
2
Motor
2) After disassembling 3 indicating screws,
detach Ass’y Case Blower Upper.
_
Press the pothook of the Case Blower
and detach Ass’y Case Blower Upper.
4-12
Samsung Electronics
Download from Www.Somanuals.com. All Manuals Search And Download.
Disassembly and Reassembly
No
Parts
Procedure
Remark
3) After disassembling 2 indicating screws,
detach the Cover Control.
4) Detach the Motor Wire Connected to
PCB and Capacitor.
5) After disassembling the indicating screws,
detach the wire connected to the
Partition.
6) After disassembling 2 indicating screws,
detach the Ass’y Band Motor.
Samsung Electronics
4-13
Download from Www.Somanuals.com. All Manuals Search And Download.
Disassembly and Reassembly
No
Parts
Procedure
Remark
7) After disassembling the Motor and
Blowers, detach the Blowers from the
axis of the Motor by 3mm inner hexagon
spanner.
3
Drain Pan
1) After disassembling 15 indicating screws,
detach Ass’y Cabinet-Top Evap.
2) After disassembling 6 indicating screws,
detach the Bracket Outlet.
3) Detach the Drain Pan.
4-14
Samsung Electronics
Download from Www.Somanuals.com. All Manuals Search And Download.
Disassembly and Reassembly
No
Parts
Procedure
Remark
✳
After finished the procedures above,
detach the Evaporator.
4
Evaporator
1) After disassembling 2 indicating screws,
detach Ass'y Cover Pipe.
2) Detach the Sensor from the
Control Box.(including 2 Sensors)
3) After disassembling 2 indicating screws,
detach Ass'y Support Evap LF.
4) After disassembling 2 indicating screws,
detach Ass'y Support Evap RH.
Samsung Electronics
4-15
Download from Www.Somanuals.com. All Manuals Search And Download.
Disassembly and Reassembly
No
Parts
Procedure
Remark
5) Detach the Evaporator from the set.
5
Control In
✳
Detach the parts of Control In after
disassembling the Cover Control.
1) Detach all the wires connected to the
PCB.
2) If only the disassembly of PCB required,
press the Pothook and detach the PCB
from the set.
3) If only the disassembly of Capacitor is
required, detach it from the set.
4) If only the disassembly of Case Control is
required, detach it from the set after
disassembling 2 indicating screws.
4-16
Samsung Electronics
Download from Www.Somanuals.com. All Manuals Search And Download.
Disassembly and Reassembly
No
Parts
Procedure
Remark
5) Detach the Transformer after
disassembling 2 indicating screws.
✳ Work is possible after disassembling
the Case PCB.
6
1) After disassembling 16 indicating screws,
detach Ass'y Bracket Outlet.
Ass'y Bracket
Outlet
Samsung Electronics
4-17
Download from Www.Somanuals.com. All Manuals Search And Download.
4-2 Outdoor Unit
4-2-1 MH050FXCA2A
No
Parts
Procedure
Remark
1) Loosen the fixing screw and detach the
Cover-Control. (Use +Screw Driver.)
2) Detach the Cable-Connector Wire from
the Terminal-Block.
1
Common Work
&
Control Out
3) Loosen the fixing screw of the Ass'y
Control Out. (Use +Screw Driver.)
4) Loosen 8 fixing screws and detach the
Cabinet Upper. (Use +Screw Driver.)
5) Loosen 2 fixing screws, 5 bolts and
detach the Front Cabinet.
(Use +Screw Driver.)
6) Loosen 2 fixing screws and pull up the
Control Box. (Use +Screw Driver.)
7) Loosen 9 fixing screws and detach the
Cabinet Side. (Use +Screw Driver.)
4-18
Samsung Electronics
Download from Www.Somanuals.com. All Manuals Search And Download.
Disassembly and Reassembly
No
Parts
Procedure
Remark
8) Detach the Terminal and detach the
Compressor Lead Wire.
1) Loosen the fixing nut and detach the Fan.
(Use +Screw Driver.)
2
Fan
&
Motor
2) Loosen 4 fixing bolts and detach the
Motor. (Use +Screw Driver.)
3) Loosen 4 fixing bolts and detach the
Bracket Motor. (Use +Screw Driver.)
Samsung Electronics
4-19
Download from Www.Somanuals.com. All Manuals Search And Download.
Disassembly and Reassembly
No
Parts
Procedure
Remark
1) Release the refrigerant at first.
2) Disassemble the Inlet and Outlet Pipe by
welding.
3
Heat Exchanger
&
Compressor
3) Loosen the fixing screws of the
Heat Exchanger. (Use +Screw Driver.)
4) Detach the Heat Exchanger.
5) Loosen 3 nuts of the Compressor.
(Use Monkey Spanner.)
6) Detach the Compressor.
4-20
Samsung Electronics
Download from Www.Somanuals.com. All Manuals Search And Download.
Disassembly and Reassembly
4-2-2 MH080FXCA4A
No
Parts
Procedure
Remark
1) Loosen 7 fixing screws and detach the
Cabinet side RH. (Use +Screw Driver.)
2) Detach the Cable-Connector Wire from
the Terminal-Block.
1
Common Work
&
Control Out
3) Loosen 2 fixing screws of the Ass'y
Control Out. (Use +Screw Driver.)
4) Loosen 6 fixing screws and detach the
Cabinet Upper. (Use +Screw Driver.)
5) Loosen 2 fixing screws, 7 bolts and
detach the Cabinet Front.
(Use +Screw Driver.)
Samsung Electronics
4-21
Download from Www.Somanuals.com. All Manuals Search And Download.
Disassembly and Reassembly
No
Parts
Procedure
Remark
6) Loosen 2 fixing screw and pull up the
Control Box. (Use +Screw Driver.)
7) Pull the felt and detach it.
8) Detach the Terminal Cover and detach
the comp lead wire.
4-22
Samsung Electronics
Download from Www.Somanuals.com. All Manuals Search And Download.
Disassembly and Reassembly
No
Parts
Procedure
Remark
1) Loosen the fixing nut and detach the Fan.
(Use Monkey Spanner.)
2
Fan
&
Motor
2) Loosen 4 fixing bolts and detach the
Motor. (Use +Screw Driver.)
3) Loosen 4 fixing bolts and detach the
Bracket Motor. (Use +Screw Driver.)
1) Release the refrigerant at first.
2) Disassemble the Inlet and Outlet Pipe by
welding.
3
Heat Exchanger
&
Compressor
3) Loosen the fixing screw of the
Heat Exchanger. (Use +Screw Driver.)
4) Detach the Heat Exchanger.
5) Loosen 3 nuts of the Compressor.
(Use Monkey Spanner.)
6) Detach the Compressor.
Samsung Electronics
4-23
Download from Www.Somanuals.com. All Manuals Search And Download.
ꢆꢁꢂ"TLHK@A@ꢂ3EASOꢂ=J@ꢂ-=NPOꢂ)EOPꢀ
ꢆꢄꢅꢂ&J@KKNꢂ2JEPꢀ
ꢆꢄꢅꢄꢅꢂ*%ꢇꢈꢉ#+ ꢃꢊ*%ꢇꢀꢆ#+ ꢃꢀ
ꢋꢀ
ꢌꢀ
ꢉꢀ
ꢄꢋꢌꢀ
ꢄꢋꢊꢀ
ꢄꢋꢄꢀ
ꢄꢋꢆꢀ
ꢄꢋꢉꢀ
ꢄꢋꢂꢀ
ꢃ
ꢁꢀ
ꢄꢋꢇꢀ
ꢍ
ꢄꢋꢈꢀ
ꢌꢋꢄꢀ
ꢌꢋꢌꢀ
ꢂꢋꢄꢀ
ꢎꢀ
ꢉꢋꢆꢀ
ꢉꢋꢈꢀ
ꢂꢋꢇꢀ
ꢉꢋꢇꢀ
ꢊꢀ
ꢉꢋꢄꢀ
ꢉꢋꢊꢀ
ꢉꢋꢌꢀ
ꢂꢋꢉꢀ
ꢉꢋꢂꢀ
ꢉꢋꢉꢀ
ꢂꢀ
ꢂꢋꢌꢀ
ꢂꢋꢄꢀ
5COUWPIꢀ'NGEVTQPKEUꢀ
Download from Www.Somanuals.com. All Manuals Search And Download.
([SORGHGꢀ9LHZVꢀDQGꢀ3DUWVꢀ/LVWꢀ
2CTVUꢄ.KUVꢀ
3 6;ꢀ
0Qꢆꢀ
%QFGꢄ0Qꢆꢀ
&GUETKRVKQPꢀ
5RGEKHKECVKQPꢀ
5#ꢏ50#ꢀ
/*ꢀꢁꢋ(0%#ꢀ /*ꢀꢊꢎ(0%#ꢀ
ꢄꢀ
&$ꢍꢇꢋꢅꢅꢇꢂꢇ,ꢀ
&$ꢍꢇꢋꢅꢅꢇꢂꢇ*ꢀ
&$ꢈꢄꢋꢅꢄꢈꢉꢌ&ꢀ
&$ꢈꢍꢋꢅꢅꢆꢉꢇ#ꢀ
&$ꢍꢈꢋꢅꢉꢄꢇꢍ#ꢀ
&$ꢍꢈꢋꢅꢉꢄꢇꢍ$ꢀ
&$ꢉꢄꢋꢅꢅꢌꢄꢍ#ꢀ
&$ꢍꢇꢋꢅꢅꢇꢂꢈ#ꢀ
&$ꢍꢊꢋꢅꢌꢅꢊꢂ#ꢀ
&$ꢍꢇꢋꢅꢅꢇꢂꢂ#ꢀ
&$ꢍꢇꢋꢇꢅꢅꢅꢊ#ꢀ
#55 ;ꢀ$#%-ꢀ$1&;ꢀ
#55 ;ꢀ
ꢋꢀ
ꢄꢀ
ꢋꢀ
5#ꢀ
5#ꢀ
#55 ;ꢀ$#%-ꢀ$1&;ꢀ
$#%-ꢀ$1&;ꢀ
#55 ;ꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢋꢀ
ꢄꢋꢄꢀ
ꢄꢋꢌꢀ
ꢄꢋꢉꢀ
*+25ꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢋꢀ
50#ꢀ
50#ꢀ
5#ꢀ
%75*+10ꢀ$#%-ꢀ$1&;ꢀ
#55 ;ꢀ5722146ꢀ'8#2ꢀ4*ꢀ
#55 ;ꢀ5722146ꢀ'8#2ꢀ4*ꢀ
/1614ꢀ+0ꢀ
'25ꢀ
*+25ꢀ
*+25ꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
5#ꢀ
ꢄꢋꢇꢀ
ꢄꢋꢂꢀ
ꢄꢋꢈꢀ
ꢄꢋꢊꢀ
ꢄꢋꢆꢀ
ꢌꢌꢅꢋꢌꢇꢅ8`ꢃꢂꢅꢁꢈꢅ*\ꢃ%NCUUꢀ'ꢀ
1&ꢍꢌZ.ꢈꢉꢂꢀ
#55 ;ꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
5#ꢀ
#55 ;ꢀ%4155ꢀ(#0ꢀ
5#ꢀ
#55 ;ꢀ$1.6ꢀ52'%+#.ꢀ
#55 ;ꢀ47$$'4ꢀ$'#4+0)ꢀ
#55 ;ꢀ$'#4+0)ꢀ/1614ꢀ
50#ꢀ
50#ꢀ
5#ꢀ
#55 ;ꢀ
$'#4+0)ꢀ
ꢌꢀ
&$ꢍꢈꢋꢅꢉꢈꢅꢆ$ꢀ
#55 ;ꢀ'8#2ꢀ616#.ꢀ
#55 ;ꢀ
ꢄꢀ
ꢄꢀ
5#ꢀ
ꢌꢋꢄꢀ
&$ꢈꢉꢋꢅꢅꢆꢂꢅ#ꢀ
%18'4ꢀ$'#4+0)ꢀ
#$5ꢀ
ꢄꢀ
ꢋꢀ
50#ꢀ
ꢌꢋꢌꢀ
&$ꢍꢈꢋꢅꢉꢅꢈꢅ)ꢀ
#55 ;ꢀ'8#2ꢀ
#55 ;ꢀ
ꢄꢀ
ꢄꢀ
50#ꢀ
ꢉꢀ
&$ꢍꢇꢋꢅꢅꢇꢂꢊ,ꢀ
#55 ;ꢀ64#;ꢀ&4#+0ꢀ
#55 ;ꢀ
ꢄꢀ
ꢄꢀ
5#ꢀ
ꢉꢋꢄꢀ
ꢉꢋꢌꢀ
ꢉꢋꢉꢀ
ꢉꢋꢇꢀ
ꢉꢋꢂꢀ
ꢉꢋꢈꢀ
ꢉꢋꢊꢀ
ꢉꢋꢆꢀ
ꢇꢀ
&$ꢈꢉꢋꢅꢅꢆꢇꢆ#ꢀ
&$ꢈꢄꢋꢅꢄꢈꢉꢂ%ꢀ
&$ꢈꢄꢋꢅꢄꢈꢉꢈ#ꢀ
&$ꢈꢉꢋꢅꢅꢆꢇꢍ#ꢀ
&$ꢈꢍꢋꢅꢅꢆꢉꢍ#ꢀ
&$ꢊꢉꢋꢅꢅꢄꢆꢅ#ꢀ
&$ꢉꢄꢋꢅꢅꢉꢊꢄ#ꢀ
&$ꢍꢇꢋꢅꢅꢇꢂꢆ$ꢀ
&$ꢍꢉꢋꢅꢈꢅꢌꢂ$ꢀ
&$ꢍꢌꢋꢅꢄꢌꢉꢊ#ꢀ
&$ꢈꢇꢋꢅꢅꢍꢆꢍ'ꢀ
&$ꢍꢌꢋꢅꢄꢌꢅꢊ#ꢀ
&$ꢍꢅꢋꢅꢉꢅꢍꢇ#ꢀ
&$ꢈꢉꢋꢅꢄꢂꢍꢄ#ꢀ
&$ꢍꢊꢋꢅꢌꢆꢂꢄ$ꢀ
&$ꢈꢄꢋꢅꢄꢈꢉꢆ$ꢀ
&$ꢍꢅꢋꢅꢉꢍꢈꢂ$ꢀ
&$ꢍꢉꢋꢅꢉꢅꢄꢌ2ꢀ
64#;ꢀ&4#+0ꢀ
#$5ꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢉꢀ
ꢉꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢉꢀ
ꢉꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢋꢀ
50#ꢀ
5#ꢀ
$.#&'ꢋ*ꢀ
*+25ꢀ
$.#&'ꢋ8ꢀ
22ꢀ
5#ꢀ
64#;ꢀ56#$+.+<'4ꢀ
%75*+10ꢀ'25ꢀ64#;ꢀ4*ꢀ
47$$'4ꢀ%#2ꢀ&4#+0ꢀ
#55 ;ꢀ/1614ꢀ56'22+0)ꢀ
#55 ;ꢀ&4#+0ꢀ*15'ꢀ
#55 ;ꢀ%10641.ꢀ+0ꢀ
#55 ;ꢀ2#0'.ꢀ(4106ꢀ
2#0'.ꢀ(4106ꢀ
#$5ꢀ
50#ꢀ
5#ꢀ
'25ꢀ
)7/ꢋ'2/ꢀ
50#ꢀ
5#ꢀ
ꢌꢌꢅꢋꢌꢇꢅ8`ꢃꢂꢅꢁꢈꢅ*\ꢃ%NCUUꢀ'ꢀ
#55 ;ꢀ
#55 ;ꢀ
#55 ;ꢀ
*+25ꢀ
#55 ;ꢀ
#55 ;ꢀ
22ꢀ
5#ꢀ
5#ꢀ
ꢂꢀ
5#ꢀ
ꢂꢋꢄꢀ
ꢂꢋꢌꢀ
ꢂꢋꢉꢀ
ꢂꢋꢇꢀ
ꢈꢀ
5#ꢀ
#55 ;ꢀ)4+..'ꢀ#+4ꢀ+0.'6ꢀ
#55 ;ꢀ%18'4ꢀ&+52.#;ꢀ
)7#4&ꢀ#+4ꢀ(+.6'4ꢀ
#55 ;ꢀ2.#6'ꢀ*#0)'4ꢀ
*1.&'4ꢀ2+2'ꢀ
5#ꢀ
5#ꢀ
50#ꢀ
50#ꢀ
50#ꢀ
5#ꢀ
#55u«;ꢀ
25ꢀ
ꢊꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢆꢀ
#55;ꢀ%18'4ꢀ6'4/+0#.ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ#66<ꢀ
#55 ;ꢀ4'/1%10ꢀ #55;ꢀꢀꢀꢀꢀꢀꢀ
ꢍꢀ
5#ꢀ
5COUWPIꢀ'NGEVTQPKEUꢀ
ꢂꢋꢌꢀ
Download from Www.Somanuals.com. All Manuals Search And Download.
Exploded Views and Parts List
5-1-2 MH052FNCA
6
7
1
1-2
14
1-1
15
10
12
11
16
2
13
4
9
2-1
2-2
2-3
3-8
3-6
5-1
5
3-4
5-4
3
3-1
3-7
3-2
5-2
5-3
3-5
3-3
8
5-2
5-3ꢀ
Samsung Electronics
Download from Www.Somanuals.com. All Manuals Search And Download.
&YQMPEFEꢀꢀ7ꢀ JFXTꢀꢀBOEꢀ1ꢀꢀBSUTꢀ-ꢀJTUꢀ
2CTVUꢄ.KUVꢀ
0Qꢆꢀ
%QFGꢄ0Qꢆꢀ
&GUETKRVKQPꢀ
5RGEKHKECVKQPꢀ
5#ꢏ50#ꢀ
3 6;ꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢌꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
5#ꢀ
50#ꢀ
50#ꢀ
5#ꢀ
&$ꢍꢇꢋꢅꢅꢈꢄꢂ$ꢀ
&$ꢈꢄꢋꢅꢄꢍꢊꢇ$ꢀ
&$ꢈꢍꢋꢅꢄꢅꢉꢍ#ꢀ
#55ŏ;ꢀ$#%-ꢀ$1&;ꢀ
#55ŏ;ꢀ
ꢄꢋꢄꢀ
ꢄꢋꢌꢀ
ꢌꢀ
$#%-ꢀ$1&;ꢀ
*+25ꢀ
%75*+10ꢋ$1&;ꢀ$#%-
'25ꢀ
&$ꢍꢈꢋꢅꢈꢂꢆꢊ&ꢀ #55ŏ;ꢀ'8#2ꢀ
#55ŏ;ꢀ
#$5ꢀ
ꢌꢋꢄꢀ
ꢌꢋꢌꢀ
ꢌꢋꢉꢀ
ꢉꢀ
50#ꢀ
5#ꢀ
&$ꢈꢉꢋꢅꢄꢅꢈꢂ#ꢀ
&$ꢍꢈꢋꢅꢊꢂꢆꢍ#ꢀ
&$ꢍꢈꢋꢅꢊꢂꢍꢅ#ꢀ
&$ꢍꢇꢋꢅꢅꢈꢄꢈ'ꢀ
&$ꢈꢉꢋꢅꢄꢅꢊꢄ#ꢀ
%18'4ꢋ$'#4+0)ꢀ
#55ŏ;ꢀ67$'ꢀ'8#2ꢀ+0ꢀ
#55ŏ;ꢀ67$'ꢀ'8#2ꢀ176ꢀ
#55ŏ;ꢀ64#;ꢀ&4#+0ꢀ
64#;ꢀ&4#+0ꢀ
#55ŏ;ꢀ
#55ŏ;ꢀ
#55ŏ;ꢀ
#$5ꢀ
5#ꢀ
5#ꢀ
ꢉꢋꢄꢀ
ꢉꢋꢌꢀ
ꢉꢋꢉꢀ
ꢉꢋꢇꢀ
ꢉꢋꢂꢀ
ꢉꢋꢈꢀ
ꢉꢋꢊꢀ
ꢉꢋꢆꢀ
5#ꢀ
&$ꢈꢄꢋꢅꢄꢍꢊꢂ%ꢀ $.#&'ꢋ*ꢀ
*+25ꢀ
5#ꢀ
&$ꢈꢄꢋꢅꢄꢍꢊꢈ#ꢀ
&$ꢈꢉꢋꢅꢄꢅꢈꢈ#ꢀ
&$ꢈꢍꢋꢅꢄꢅꢌꢇ#ꢀ
&$ꢊꢉꢋꢅꢅꢄꢆꢅ#ꢀ
$.#&'ꢋ8ꢀ
22ꢀ
5#ꢀ
50#ꢀ
50#ꢀ
50#ꢀ
5#ꢀ
64#;ꢋ56#$+.+<'4ꢀ
%75*+10ꢀ64#;ꢀ4*ꢀ
47$$'4ꢋ%#2ꢀ&4#+0ꢀ
#$5ꢀ
'25ꢀ
)7/ꢋ'2/ꢀ
)52ꢋꢌꢇ19ꢀꢅꢇꢈꢀ
#55ŏ;ꢀ
&$ꢉꢄꢋꢅꢅꢌꢆꢂꢀ#ꢀ #55ŏ;ꢀ/1614ꢋ56'22+0)ꢀ
&$ꢍꢇꢋꢅꢅꢇꢂꢆ$ꢀ
#55ŏ;ꢀ&4#+0ꢋ*15'ꢀ
&$ꢍꢉꢋꢅꢈꢅꢉꢆ$ꢀ #55ŏ;ꢀ%10641.ꢀ+0ꢀ
&$ꢍꢌꢋꢅꢄꢌꢉꢂ#ꢀ
#55ŏ;ꢀ2#0'.ꢀ(4106ꢀ
&$ꢈꢇꢋꢅꢄꢄꢆꢇ%ꢀ 2#0'.ꢀ(4106ꢀ
5#ꢀ
ꢇꢀ
ꢂꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
5#ꢀ
5#ꢀ
5#ꢀ
#55ŏ;ꢀ
#55ŏ;ꢀ
*+25ꢀ
ꢂꢋꢄꢀ
ꢂꢋꢌꢀ
ꢂꢋꢉꢀ
ꢂꢋꢇꢀ
ꢈꢀ
ꢄꢀ
ꢄꢀ
ꢌꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
&$ꢍꢌꢋꢅꢄꢄꢍꢈ#ꢀ
#55ŏ;ꢀ)4+..'ꢋ#+4ꢀ+0.'6ꢀ
#55ŏ;ꢀ
#55ŏ;ꢀ
22ꢀ
&$ꢍꢉꢋꢅꢌꢆꢈꢊ%ꢀ #55ŏ;ꢀ%18'4ꢋ&+52.#;ꢀ
&$ꢈꢉꢋꢅꢄꢂꢍꢌ$ꢀ
&$ꢍꢅꢋꢅꢌꢊꢉꢆ#ꢀ
&$ꢈꢄꢋꢅꢄꢍꢆꢄ$ꢀ
&$ꢍꢅꢋꢅꢉꢍꢈꢈ$ꢀ
)7#4&ꢋ#+4ꢀ(+.6'4ꢀ
#55ŏ;ꢋ2.#6'ꢀ*#0)'4ꢀ
*1.&'4ꢋ2+2'ꢀ
5)%%6ꢅꢐꢈꢀ
*+25ꢀ
*+25ꢀ
*2ꢀ
ꢊꢀ
ꢆꢀ
#55ŏ;ꢀ%18'4ꢀ6'4/+0#.ꢀ
ꢍꢀ
&$ꢍꢉꢋꢅꢉꢅꢄꢌ2ꢀ #55ŏ;ꢀ4'/1%10ꢀ
ꢄꢅꢀ
ꢄꢄꢀ
ꢄꢌꢀ
ꢄꢉꢀ
ꢄꢇꢀ
ꢄꢂꢀ
ꢄꢈꢀ
&$ꢍꢈꢋꢅꢉꢆꢄꢊ#ꢀ
&$ꢉꢄꢋꢅꢅꢌꢈꢊ#ꢀ
&$ꢍꢇꢋꢅꢅꢇꢂꢈ$ꢀ
&$ꢍꢊꢋꢅꢌꢅꢊꢂ#ꢀ
&$ꢍꢇꢋꢅꢅꢇꢂꢂ#ꢀ
&$ꢍꢇꢋꢇꢅꢅꢅꢊ#ꢀ
#55ŏ;ꢀ'8#2ꢋ5722146ꢀ4*ꢀ
*+25ꢀ
ꢂꢅꢁꢈꢅ*<ꢀ
#55ŏ;ꢀ
ꢋꢀ
/1614ꢀ(#0ꢀ
#55ŏ;ꢀ%4155ꢀ(#0ꢀ
#55ŏ;ꢀ$1.6ꢋ52'%+#.ꢀ
#55ŏ;ꢀ$'#4+0)ꢋ47$$'4ꢀ
#55ŏ;ꢀ$'#4+0)ꢋ/1614ꢀ
ꢋꢀ
ꢄꢀ
5#ꢀ
ꢋꢀ
5)%%ꢋ/ꢀ
ꢄꢀ
5#ꢀ
&$ꢈꢄꢋꢅꢄꢍꢊꢊ#ꢀ $4#%-'6ꢀ'8#2ꢀ
5COUWPIꢀ'NGEVTQPKEUꢀ
ꢂꢋꢃꢀ
Download from Www.Somanuals.com. All Manuals Search And Download.
Exploded Views and Parts List
5-1-3 MH026FECA/MH035FECA
1
8
20
19
21
2
17
18
16
15
13
12
11
24
25
23
4
14
3
5
9
22
10
8
6
7
23-5
23-6
23-4
23-1
23-7
23-8
23-3
23-2
5-5
Samsung Electronics
Download from Www.Somanuals.com. All Manuals Search And Download.
Exploded Views and Parts List
■
Parts List
%QFGꢄ0Qꢆꢀ
&GUETKRVKQPꢀ
5RGEKHKECVKQPꢀ
3 6;ꢀ
5#ꢏ50#ꢀ
0Qꢆꢀ
ꢄꢀ
ꢌꢀ
&$ꢍꢅꢋꢅꢌꢅꢄꢇ#ꢀ
&$ꢈꢇꢋꢅꢄꢉꢌꢇ#ꢀ
&$ꢍꢅꢋꢅꢄꢍꢂꢄ#ꢀ
&$ꢍꢅꢋꢅꢄꢍꢉꢆ#ꢀ
&$ꢍꢅꢋꢅꢄꢍꢂꢅ#ꢀ
&$ꢈꢇꢋꢅꢄꢉꢌꢈ#ꢀ
&$ꢍꢅꢋꢅꢌꢅꢈꢍ'ꢀ
&$ꢈꢄꢋꢅꢌꢌꢊꢇ#ꢀ
&$ꢍꢇꢋꢅꢅꢊꢄꢌ#ꢀ
&$ꢈꢄꢋꢅꢌꢌꢊꢊ#ꢀ
&$ꢍꢇꢋꢅꢉꢉꢂꢉ#ꢀ
&$ꢍꢈꢋꢅꢂꢌꢆꢍ#ꢀ
&$ꢍꢅꢋꢅꢄꢍꢊꢆ#ꢀ
&$ꢍꢅꢋꢅꢄꢍꢇꢈ#ꢀ
&$ꢍꢇꢋꢅꢅꢊꢈꢆ#ꢀ
&$ꢈꢄꢋꢅꢌꢌꢆꢌ#ꢀ
&$ꢍꢍꢋꢅꢅꢈꢈꢍ#ꢀ
&$ꢉꢄꢋꢅꢅꢉꢉꢉ$ꢀ
&$ꢈꢊꢋꢅꢅꢂꢈꢂ#ꢀ
&$ꢍꢅꢋꢅꢄꢍꢇꢊ#ꢀ
&$ꢍꢅꢋꢅꢄꢍꢇꢆ#ꢀ
&$ꢍꢇꢋꢅꢅꢇꢇꢉ%ꢀ
&$ꢍꢉꢋꢅꢄꢄꢉꢈ'ꢀ
&$ꢍꢅꢋꢅꢄꢍꢇꢄ%ꢀ
&$ꢈꢄꢋꢅꢌꢌꢆꢊ%ꢀ
&$ꢈꢉꢋꢅꢄꢌꢉꢊ#ꢀ
&$ꢈꢄꢋꢇꢆꢅꢃꢂ$ꢀ
&$ꢈꢂꢋꢅꢅꢄꢅꢂ.ꢀ
&$ꢈꢂꢋꢅꢅꢄꢅꢂ/ꢀ
&$ꢌꢈꢋꢇꢇꢇꢊꢇ$ꢀ
ꢌꢉꢅꢄꢋꢅꢅꢄꢉꢊꢅꢀ
&$ꢉꢌꢋꢅꢅꢄꢇꢌ#ꢀ
&$ꢉꢌꢋꢅꢅꢄꢇꢄ#ꢀ
#55 ;ꢀ%#$+0'6ꢀ$#5'ꢀ
#55 ;ꢀ%#$+0'6ꢀ5+&'ꢀ.(ꢀ
#55 ;ꢀ%#$+0'6ꢀ5+&'ꢀ4*ꢀ
#55 ;ꢀ%18'4ꢀ2+2'ꢀ
#55 ;ꢀ%18'4ꢀ&4#+0ꢀ27/2ꢀ
%#$+0'6ꢀ612ꢀ/1614ꢀ
#55 ;ꢀ%#$+0'6ꢀ612ꢀ'8#2ꢀ
2.#6'ꢀ*#0)'4ꢀ
#55 ;ꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢌꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢌꢀ
ꢌꢀ
ꢌꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
50#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
#55 ;ꢀ
ꢉꢀ
#55 ;ꢀ
ꢇꢀ
#55 ;ꢀ
ꢂꢀ
#$5ꢀ6ꢌꢐꢅꢀ
5)%%ꢋ/ꢃꢀ6ꢅꢐꢆꢀ
#55 ;ꢀ
ꢈꢀ
ꢊꢀ
ꢆꢀ
5)%%ꢋ/ꢀ6ꢌꢐꢅꢀ
#55 ;ꢀ
ꢍꢀ
#55 ;ꢀ$4#%-'6ꢀ176.'6ꢀ
$4#%-'6ꢀ176.'6ꢀ57$ꢀ
#55 ;ꢀ%75*+10ꢀ$#5'ꢀ
#55 ;ꢀ'8#2ꢀ70+6ꢀ
ꢄꢅꢀ
ꢄꢄꢀ
5)%%ꢋ/ꢃꢀ6ꢅꢐꢆꢀ
#55 ;ꢀ
ꢄꢌꢀ
ꢄꢉꢀ
ꢄꢇꢀ
ꢄꢂꢀ
ꢄꢈꢀ
ꢄꢊꢀ
ꢄꢆꢀ
ꢄꢍꢀ
ꢌꢅꢀ
ꢌꢄꢀ
ꢌꢌꢀ
ꢌꢉꢀ
ꢌꢉꢋꢄꢀ
ꢌꢉꢋꢌꢀ
ꢌꢉꢋꢉꢀ
ꢌꢉꢋꢇꢀ
ꢌꢉꢋꢂꢀ
ꢌꢉꢋꢈꢀ
ꢌꢉꢋꢊꢀ
ꢌꢉꢋꢆꢀ
ꢌꢇꢀ
ꢌꢂꢀ
#55 ;ꢀ
#55 ;ꢀ5722146ꢀ'8#2ꢀ.(ꢀ
#55 ;ꢀ5722146ꢀ'8#2ꢀ4*ꢀ
#55 ;ꢀ2#46+6+10ꢀ
#55 ;ꢀ
#55 ;ꢀ
#55 ;ꢀ
$4#%-'6ꢀ/1614ꢀ
5)%%ꢋ/ꢀ6ꢌꢐꢅꢀ
5+0;#ꢀ
#55 ;ꢀ$#0&ꢀ/1614ꢀ
/1614ꢀ(#0ꢀ
5+0;#ꢃꢀ554ꢃꢀ2+&ꢀ
$.19'4ꢀ
#55 ;ꢃꢀ#$5ꢃꢀ6145+10#.ꢀ$75*ꢀ
#55 ;ꢀ
#55 ;ꢀ%#5'ꢀ$.19'4ꢀ722'4ꢀ
#55 ;ꢀ%#5'ꢀ$.19'4ꢀ$1661/ꢀ
#55 ;ꢀ&4#+0ꢀ2#0ꢀ
#55 ;ꢀ
#55 ;ꢀ
#55 ;ꢀ%10641.ꢀ+0ꢀ
#55 ;ꢀ%#5'ꢀ%10641.ꢀ
%#5'ꢀ2%$ꢀ
#55 ;ꢀ
50#ꢀ
5#ꢀ
#55 ;ꢀ
#$5ꢀ6ꢌꢐꢂꢀ
5#ꢀ
%18'4ꢀ%10641.ꢀ
5)%%ꢋ/ꢀ6ꢅꢐꢂꢀ
22ꢀ$.#%-
ꢈ2ꢃꢀ219'4ꢀ
ꢈ2ꢃꢀ%1//70+%#6+10ꢀ
ꢌꢉꢅ8ꢃꢀꢂꢅ*<ꢀ
ꢇꢂꢅ8ꢀꢄꢐꢂz(ꢀ
#55 ;ꢀ
5#ꢀ
*1.&'4ꢀ9+4'ꢀ
50#ꢀ
50#ꢀ
50#ꢀ
50#ꢀ
5#ꢀ
6'4/+0#.ꢀ$.1%-ꢀꢈ2ꢀ
6'4/+0#.ꢀ$.1%-ꢀꢈ2ꢀ
64#05ꢀ219'4ꢀ
%#2#%+614ꢀ
#55 ;ꢀ6*'4/+5614ꢀ
6*'4/+5614ꢀ'8#2ꢀ
5#ꢀ
#55 ;ꢀ
50#ꢀ
Samsung Electronics
5-6
Download from Www.Somanuals.com. All Manuals Search And Download.
Exploded Views and Parts List
5-1-4 MH052FECA
28
27
8
2
26
22
21
1
25
20
23
18
24
19
17
16
3
33
4
11
5
31
8
12
13
14
32
30
15
10
9
6
29
30-1
30-6
30-2
34
30-3
7
30-4
30-5
35
5-7
Samsung Electronics
Download from Www.Somanuals.com. All Manuals Search And Download.
Exploded Views and Parts List
■
Parts List
%QFGꢄ0Qꢆꢀ
&GUETKRVKQPꢀ
#55 ;ꢀ%#$+ꢀ$#5'ꢀ
5RGEKHKECVKQPꢀ
#55 ;ꢃ5)%%ꢋ/ꢃ6ꢅꢐꢆꢀꢀꢀꢀ
3 6;ꢀ
5#ꢏ50#ꢀ
0Qꢆꢀ
ꢄꢀ
ꢌꢀ
&$ꢍꢅꢋꢅꢌꢄꢈꢅ#ꢀ
&$ꢈꢇꢋꢅꢄꢉꢌꢇ$ꢀ
&$ꢍꢅꢋꢅꢄꢍꢂꢄ#ꢀ
&$ꢍꢅꢋꢅꢄꢍꢉꢆ#ꢀ
&$ꢍꢅꢋꢅꢄꢍꢂꢅ#ꢀ
&$ꢈꢇꢋꢅꢄꢉꢇꢂ#ꢀ
&$ꢍꢅꢋꢅꢌꢄꢈꢄ%ꢀ
&$ꢈꢄꢋꢅꢌꢌꢊꢇ#ꢀ
&$ꢍꢊꢋꢅꢉꢊꢍꢈ#ꢀ
&$ꢈꢄꢋꢅꢌꢉꢌꢌ#ꢀ
&$ꢍꢊꢋꢅꢉꢊꢍꢌ#ꢀ
&$ꢍꢊꢋꢅꢉꢊꢍꢄ#ꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢌꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢌꢀ
ꢉꢀ
ꢉꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢌꢀ
ꢄꢀ
ꢄꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
%#$+ꢀ5+&'ꢀ.(ꢀ
5)%%ꢋ/ꢃ6ꢅꢐꢆꢀꢀ
#55 ;ꢃ5)%%ꢋ/ꢃ6ꢅꢐꢆꢀꢀꢀ
#55 ;ꢃ5)%%ꢋ/ꢃ6ꢅꢐꢂꢀ
#55 ;ꢀ
ꢉꢀ
#55 ;ꢀ%#$+ꢀ5+&'ꢀ4*ꢀ
#55 ;ꢀ%18'4ꢀ2+2'ꢀ
ꢇꢀ
ꢂꢀ
#55 ;ꢀ%18'4ꢀ&4#+0ꢀ27/2ꢀ
%#$+ꢀꢀ612ꢀ/1614ꢀ
ꢈꢀ
5)%%ꢋ/ꢃ6ꢅꢐꢆꢀꢀꢀꢀꢀ
#55 ;ꢃ5)%%ꢋ/ꢃ6ꢅꢐꢆꢀꢀꢀ
5)%%ꢋ/ꢃ6ꢌꢐꢅꢀ
#55 ;ꢃ5)%%ꢋ/ꢃ6ꢅꢐꢆꢀ
5)%%ꢋ/ꢃ6ꢅꢐꢆꢀꢀ
#55 ;ꢃ'25ꢀꢌꢂꢀꢀ
#55 ;ꢃ'25ꢀꢌꢂꢀ
#55 ;ꢀ
ꢊꢀ
#55 ;ꢀ%#$+ꢀ612ꢀ'8#2ꢀ
2.#6'4ꢀ*#0)'4ꢀ
ꢆꢀ
ꢍꢀ
#55 ;ꢀ$4#%-'6ꢀ176.'6ꢀ
$4#%-'6ꢀ176.'6ꢀ57$ꢀ
#55 ;ꢀ%75*+10ꢀ$#5'ꢀ#ꢀ
#55 ;ꢀ%75*+10ꢀ$#5'ꢀ$ꢀꢀ
ꢄꢅꢀ
ꢄꢄꢀ
ꢄꢌꢀ
ꢄꢉꢀ
ꢄꢇꢀ
ꢄꢂꢀ
ꢄꢈꢀ
ꢄꢊꢀ
ꢄꢆꢀ
ꢄꢍꢀ
ꢌꢅꢀ
ꢌꢄꢀ
ꢌꢌꢀ
ꢌꢉꢀ
ꢌꢇꢀ
ꢌꢂꢀ
ꢌꢈꢀ
ꢌꢊꢀ
ꢌꢆꢀ
ꢌꢍꢀ
ꢉꢅꢀ
ꢉꢅꢋꢄꢀ
ꢉꢅꢋꢌꢀ
ꢉꢅꢋꢉꢀ
ꢉꢅꢋꢇꢀ
ꢉꢅꢋꢂꢀ
ꢉꢅꢋꢈꢀ
ꢉꢄꢀ
ꢉꢌꢀ
ꢉꢉꢀ
ꢉꢇꢀ
ꢉꢂꢀ
&$ꢍꢈꢋꢅꢂꢉꢈꢊ$ꢀ #55 ;ꢀ'8#2ꢀ70+6ꢀ
#55 ;ꢀ5722146ꢀ'8#2ꢀ.(ꢀ
&$ꢍꢅꢋꢅꢄꢍꢊꢆ#ꢀ
&$ꢍꢅꢋꢅꢄꢍꢇꢈ#ꢀ
&$ꢍꢇꢋꢅꢅꢆꢅꢍ#ꢀ
&$ꢈꢄꢋꢅꢌꢌꢆꢌ#ꢀ
&$ꢍꢊꢋꢅꢉꢆꢅꢅ#ꢀ
&$ꢉꢄꢋꢅꢅꢉꢄꢇ&ꢀ
&$ꢈꢈꢋꢅꢄꢅꢅꢊ#ꢀ
&$ꢍꢇꢋꢅꢅꢊꢂꢍ#ꢀ
&$ꢈꢊꢋꢅꢅꢂꢆꢄ#ꢀ
&$ꢊꢉꢋꢅꢅꢌꢆꢂ#ꢀ
&$ꢍꢈꢋꢅꢇꢍꢅꢌ#ꢀ
&$ꢈꢊꢋꢅꢅꢂꢈꢂ#ꢀ
&$ꢈꢊꢋꢅꢅꢂꢊꢈ#ꢀ
&$ꢍꢅꢋꢅꢄꢍꢇꢊ#ꢀ
&$ꢍꢅꢋꢅꢄꢍꢇꢆ#ꢀ
&$ꢍꢇꢋꢅꢄꢅꢅꢊ#ꢀ
#55 ;ꢃ5)%%ꢋ/ꢃ6ꢅꢐꢆꢀ
#55 ;ꢃ5)%%ꢋ/ꢃ6ꢅꢐꢆꢀꢀ
#55 ;ꢃ5)%%ꢋ/ꢃ6ꢄꢐꢅꢀ
5)%%ꢋ/ꢃ6ꢌꢐꢅꢀ
5+0;#ꢃ#55 ;ꢀ
5+0;#ꢃꢂꢅ*<ꢃ;5-ꢄꢇꢅꢋꢈꢅꢋꢇ2)ꢀ
5+0;#ꢀ
#55 ;ꢀ5722146ꢀ'8#2ꢀ4*ꢀ
#55 ;ꢀ2#46+6+10ꢀ
$4#%-'6ꢀ/1614ꢀ
#55 ;ꢀ$#0&ꢀ/1614ꢀ
/1614ꢀ
/1614ꢀ5*#(6ꢀ
/1.&ꢀ$'#4+0)ꢀ
%#2ꢀ$'#4+0)ꢀ
#55 ;ꢀ
5)%%ꢋ/ꢃ6ꢅꢐꢆꢀ
%4ꢀ8ꢅꢀ
47$$'4ꢀ5*#(6ꢀ
%172.'4ꢀ
#55 ;ꢀ
$.19'4ꢀ#ꢀ
#55 ;ꢃ#$5ꢀ
$.19'4ꢀ$ꢀ
#55 ;ꢃ#$5ꢀ
#55 ;ꢀ%#5'ꢀ$.19'4ꢀ722'4ꢀ
#55 ;ꢀ%#5'ꢀ$.19'4ꢀ$1661/ꢀ
#55 ;ꢀ&4#+0ꢀꢀ
#55 ;ꢀ#$5ꢀ
#55 ;ꢀ#$5ꢀ
#55 ;ꢀ
&$ꢍꢉꢋꢅꢄꢄꢉꢈ&ꢀ #55 ꢀ;ꢀ%10641.ꢀ+0ꢀꢀ
#55 ;ꢀ
&$ꢍꢅꢋꢅꢄꢍꢇꢄ%ꢀ
&$ꢈꢄꢋꢅꢌꢌꢆꢊ%ꢀ
ꢌꢉꢅꢄꢋꢅꢅꢄꢉꢊꢍꢀ
&$ꢈꢂꢋꢅꢅꢄꢅꢂ.ꢀ
&$ꢈꢂꢋꢅꢅꢄꢅꢂ/ꢀ
&$ꢌꢈꢋꢄꢅꢅꢊꢅ)ꢀ
&$ꢉꢌꢋꢅꢅꢄꢇꢌ#ꢀ
&$ꢉꢌꢋꢅꢅꢄꢇꢄ#ꢀ
&$ꢈꢄꢋꢅꢌꢉꢇꢍ#ꢀ
&$ꢍꢅꢋꢅꢌꢄꢅꢄ#ꢀ
&$ꢍꢉꢋꢅꢄꢂꢄꢂ&ꢀ
#55 ;ꢀ%#5'ꢀ%10641.ꢀ
%#5'ꢀ2%$ꢀ
#55 ;ꢀ
#$5ꢀ8ꢅꢃ6ꢌꢐꢂꢃꢋꢃꢋꢃꢋꢃꢋꢀ
ꢇꢂꢅ8ꢃꢇ7ꢀ
%#2#%+614ꢀ
6'4/+0#.ꢀ$.1%-ꢀꢈ2ꢀ
6'4/+0#.ꢀ$.1%-ꢀꢈ2ꢀ
64#05ꢀ219'4ꢀ
ꢈ2ꢃ219'4ꢀ
ꢈ2ꢃ%1//70+%#6+10ꢀ
ꢈꢅ*<ꢀ
#55 ;ꢀ6*'4/+5614ꢀꢀꢀꢀꢀꢀꢀꢀ
6*'4/+5614ꢀ'8#2ꢀ
%.+2ꢀ$475*ꢀ
#55 ;ꢀ
ꢆꢅꢅOOꢀ
0;.10ꢈꢈꢃ$.#%-
#55 ;ꢀ
#55 ;ꢀ%18'4ꢀ%10641.ꢀ
#55 ;ꢀ2%$ꢀ
#55 ;ꢀ
Samsung Electronics
5-8
Download from Www.Somanuals.com. All Manuals Search And Download.
5-2 Outdoor Unit
5-2-1 MH050FXCA2A
ꢉꢋꢀ
8
ꢄꢈꢋꢌꢀ
ꢄꢈꢋꢄꢀ
ꢄꢈꢋꢉꢀ
ꢄꢈꢋꢇꢀ
ꢄꢈꢋꢈꢀ
ꢄꢈꢋꢆꢀ
ꢄꢈꢋꢄꢄꢀ
ꢄꢈꢋꢍꢀ
7
ꢄꢈꢋꢂꢀ
ꢄꢈꢋꢊꢀ
ꢄꢈꢋꢄꢅꢀ
11
17
6
5
4
12
ꢉꢊꢇ
3
2
15
ꢉꢃꢀ
ꢄꢉꢋꢄꢀ
9
1
19
18
10
1-1
5-9
Samsung Electronics
Download from Www.Somanuals.com. All Manuals Search And Download.
Exploded Views and Parts List
2CTVUꢄ.KUVꢀ
3 6;ꢀ
0Qꢆꢀ
%QFGꢄ0Qꢆꢀ
&GUETKRVKQPꢀ
5RGEKHKECVKQPꢀ
5#ꢏ50#ꢀ
/*ꢀꢎꢀ(:%#ꢁ#ꢀ
ꢄꢀ
ꢄꢋꢄꢀ
ꢌꢀ
&$ꢍꢅꢋꢅꢄꢄꢇꢈ)ꢀ
&$ꢈꢉꢋꢅꢅꢆꢉꢆ%ꢀ
&$ꢍꢅꢋꢅꢉꢌꢊꢆ%ꢀ
&$ꢈꢊꢋꢅꢅꢄꢇꢌ#ꢀ
&$ꢉꢄꢋꢅꢅꢇꢍꢌ#ꢀ
&$ꢈꢄꢋꢅꢅꢈꢆꢈ#ꢀ
&$ꢍꢇꢋꢅꢄꢉꢌꢈ#ꢀ
&$ꢍꢈꢋꢅꢂꢀꢀꢄꢀ
#55 ;ꢀ%#$+0'6ꢀ(4106ꢀ
)7#4&ꢀ(#0ꢀ
#55 ;ꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢉꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
5#ꢀ
5#ꢀ
50#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
50#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
50#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
50#ꢀ
50#ꢀ
5#ꢀ
50#ꢀ
50#ꢀ
5%ꢀ
5%ꢀ
5%ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
5#ꢀ
22ꢃ5%ꢋꢍꢅꢅꢊꢉ4ꢀ
#55 ;ꢀ$#5'ꢀ176ꢀ
(#0ꢀ2412'..'4ꢀ
/1614ꢀ(#0ꢀ
#55 ;ꢀ
ꢉꢀ
22ꢀ
ꢇꢀ
5)%%ꢋ/ꢀ
ꢂꢀ
$4#%-'6ꢀ/1614ꢀ
#55 ;ꢀ2#46+6+10ꢀ
#55 ;ꢀ%10&'05'4ꢀ
5%4''0ꢋ%10&ꢀ$#4ꢀ
#55 ;ꢀ%#$+0'6ꢀ5+&'ꢀ
#55 ;ꢀ%18'4ꢀ%10641.ꢀ
#55 ;ꢀ%#$+0'6ꢀ72ꢀ
#55 ;ꢀ%#$+0'6ꢀ.(ꢀ
#55 ;ꢀ
ꢈꢀ
#55 ;ꢀ
ꢊꢀ
#55 ;ꢀ
ꢆꢀ
&$ꢈꢇꢋꢅꢌꢅꢆꢉ$ꢀ
&$ꢍꢅꢋꢅꢉꢅꢍꢈ%ꢀ
&$ꢍꢅꢋꢅꢉꢆꢇꢄ#ꢀ
&$ꢍꢅꢋꢅꢉꢌꢊꢂ#ꢀ
&$ꢍꢅꢋꢅꢄꢉꢂꢄ#ꢀ
*594ꢎ5%ꢋꢍꢅꢅꢊꢉ6ꢏꢀ
ꢍꢀ
#55 ;ꢀ
ꢄꢅꢀ
#55 ;ꢀ
ꢄꢄꢀ
#55 ;ꢀ
ꢄꢌꢀ
5'%%ꢋ2ꢀ
ꢄꢉꢀ
)ꢆ6ꢌꢅꢅ(7#'9ꢀ 416#4;ꢀ%1/24'5514ꢀ
$.&%ꢀ2'4/#0'06ꢀ/#)0'6+%ꢀ/1614ꢀ
ꢄꢉꢋꢄꢀ
ꢄꢇꢀ
&$ꢈꢉꢋꢅꢅꢊꢈꢉ#ꢀ
&$ꢍꢈꢋꢅꢆꢍꢅꢍ#ꢀ
&$ꢍꢈꢋꢅꢆꢍꢄꢅ$ꢀ
&$ꢍꢉꢋꢅꢂꢈꢍꢊ&ꢀ
&$ꢍꢉꢋꢅꢂꢊꢅꢅ&ꢀ
&$ꢈꢄꢋꢅꢌꢍꢊꢇ%ꢀ
&$ꢈꢌꢋꢅꢄꢆꢅꢄ$ꢀ
&$ꢍꢉꢋꢅꢇꢊꢇꢂ$ꢀ
&$ꢈꢄꢋꢅꢌꢍꢊꢉ%ꢀ
&$ꢊꢅꢋꢅꢅꢊꢉꢅ#ꢀ
&$ꢊꢅꢋꢅꢅꢂꢀꢊ$ꢀ
&$ꢈꢂꢋꢅꢅꢄꢆꢄ&ꢀ
&$ꢈꢂꢋꢅꢅꢄꢆꢄ(ꢀ
&$ꢍꢂꢋꢅꢄꢄꢆꢅ#ꢀ
&$ꢍꢉꢋꢅꢈꢌꢍꢅ#ꢀ
&$ꢌꢊꢋꢅꢅꢅꢇꢌ#ꢀ
&$ꢉꢌꢋꢅꢅꢄꢊꢂ$ꢀ
&$ꢉꢌꢋꢅꢅꢄꢊꢈ#ꢀ
)41//'6ꢋ+51.#614ꢀ
#55 ;ꢀ8#.8'ꢀꢇꢋ9#;ꢀ
#55 ;ꢀ8#.8'ꢀ
04ꢀ
#55 ;ꢀ
ꢄꢂꢀ
#55 ;ꢀ
ꢄꢈꢀ
#55 ;ꢀ%10641.ꢀ176ꢀ
#55 ;ꢀ2%$ꢀ/#+0ꢀ
#55 ;ꢀ
ꢄꢈꢋꢄꢀ
ꢄꢈꢋꢌꢀ
ꢄꢈꢋꢉꢀ
ꢄꢈꢋꢇꢀ
ꢄꢈꢋꢂꢀ
ꢄꢈꢋꢈꢀ
ꢄꢈꢋꢊꢀ
ꢄꢈꢋꢆꢀ
ꢄꢈꢋꢍꢀ
ꢄꢈꢋꢄꢅꢀ
ꢄꢈꢋꢄꢄꢀ
ꢄꢊꢀ
#55 ;ꢀ
%#5'ꢀ%10641.ꢋ%18'4ꢀ
*'#6ꢀ5+0-
#55 ;ꢀ
#$5ꢀ
#55 ;ꢀ2%$ꢀ'/+ꢀ
#55 ;ꢀ
%#5'ꢀ%10641.ꢋ$#5'ꢀ
2.#6'ꢋ%10641.ꢀ176ꢀ722'4ꢀ
2.#6'ꢋ%10641.ꢀ176ꢀ/#+0ꢀ
6'4/+0#.ꢀ$.1%-
#.ꢀ
#$5ꢀ
5)%%ꢋ/ꢀ
$.-
6'4/+0#.ꢀ$.1%-
$.-
#55 ;ꢋ6'4/+0#.ꢀ$.1%-
#55 ;ꢀ2%$ꢀ&+52.#;ꢀ
#55 ;ꢀ
#55 ;ꢀ
ꢀ
4'#%614ꢀ
ꢂ/*vꢂꢓꢃꢇꢅꢐꢅvꢂ8ꢀ
ꢄꢅꢉ#6ꢃꢌꢅꢇ%6$ꢀ
ꢄꢅꢉ#6ꢃꢌꢅꢇ%6$ꢀ
ꢄꢆꢀ
6*'4/+5614ꢀ%10&'05'4ꢀ
ꢄꢍꢀ
6*'4/+5614ꢀꢀ
Samsung Electronics
5-10
Download from Www.Somanuals.com. All Manuals Search And Download.
Exploded Views and Parts List
5-2-2 MH080FXCA4A
ꢉꢋꢀ
ꢄꢈꢋꢌꢀ
ꢄꢈꢋꢄꢀ
ꢄꢈꢋꢉꢀ
ꢄꢈꢋꢇꢎ
ꢄꢈꢋꢈꢀ
ꢄꢈꢋꢊꢎ
11
ꢄꢈꢋꢄꢅꢀ
8
ꢄꢈꢋꢆꢀ
ꢄꢈꢋꢂꢎ
ꢄꢈꢋꢍꢎ
7
17
12
5
6
10
20
4
13
15
2
13-1
9
3
1
14
19
1-1
18
5-11
Samsung Electronics
Download from Www.Somanuals.com. All Manuals Search And Download.
Exploded Views and Parts List
■
Parts List
3 6;ꢀ
0Qꢆꢀ
%QFGꢄ0Qꢆꢀ
&GUETKRVKQPꢀ
5RGEKHKECVKQPꢀ
5#ꢏ50#ꢀ
/*ꢀꢂꢀ(:'#ꢃ$ꢀ
ꢄꢀ
ꢄꢋꢄꢀ
ꢌꢀ
&$ꢍꢅꢋꢅꢉꢍꢄꢆ#ꢀ
&$ꢈꢉꢋꢅꢅꢆꢉꢄ%ꢀ
&$ꢍꢅꢋꢅꢉꢌꢊꢆ%ꢀ
&$ꢈꢊꢋꢅꢅꢆꢈꢄ#ꢀ
&$ꢉꢄꢋꢅꢅꢂꢄꢌ#ꢀ
&$ꢈꢄꢋꢌꢅꢅꢍꢇ&ꢀ
&$ꢍꢇꢋꢅꢄꢊꢀꢃ$ꢀ
&$ꢍꢈꢋꢅꢍꢌꢌꢉ#ꢀ
&$ꢊꢄꢋꢅꢅꢄꢌꢌ%ꢀ
&$ꢍꢅꢋꢅꢉꢍꢌꢅ#ꢀ
&$ꢍꢅꢋꢅꢉꢍꢄꢍ#ꢀ
&$ꢍꢅꢋꢅꢉꢌꢊꢂ#ꢀ
&$ꢍꢅꢋꢅꢉꢍꢉꢌ#ꢀ
#55ŏ;ꢀ%#$+ꢀ(4106ꢋ616#.ꢀ
)7#4&ꢀ(#0ꢋ2ꢀ
#55ŏ;ꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢉꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
ꢄꢀ
50#ꢀ
5#ꢀ
22ꢃ5%ꢋꢍꢅꢅꢊꢉ4ꢀ
#55ŏ;ꢀ
#55ŏ;ꢀ$#5'ꢀ176ꢋ616#.ꢀ
(#0ꢀ241('..'4ꢀ
50#ꢀ
50#ꢀ
5#ꢀ
ꢉꢀ
#5ꢋ)(ꢀꢌꢅꢓꢀ
ꢈꢂ#ꢃꢄꢉꢅ9ꢃ&%ꢀꢉꢄꢅ8ꢀ
5)%%ꢋ/ꢀ
#55ŏ;ꢀ
ꢇꢀ
/1614ꢀ(#0ꢀ
ꢂꢀ
$#5'ꢀ/1614ꢀ
50#ꢀ
50#ꢀ
50#ꢀ
50#ꢀ
50#ꢀ
50#ꢀ
50#ꢀ
50#ꢀ
5#ꢀ
ꢈꢀ
#55ŏ;ꢀ2#46+6+10ꢀ
#55ŏ;ꢀ%10&ꢀ
ꢊꢀ
#55ŏ;ꢀ
ꢆꢀ
$#4ꢀ56''.ꢀ
*594ꢀ
ꢍꢀ
#55ŏ;ꢀ%#$+0'6ꢋ5+&'ꢀ4*ꢀ
#55ŏ;ꢀ%#$+ꢀ$#%-ꢋ4*ꢀ
#55ŏ;ꢀ%#$+0'6ꢀ72ꢀ
#55ŏ;ꢀ%#$+0'6ꢋ5+&'ꢀ.(ꢀ2#+06ꢀ
#55ŏ;ꢀ
ꢄꢅꢀ
#$5ꢀ
ꢄꢄꢀ
#55ŏ;ꢀ
ꢄꢌꢀ
#55ŏ;ꢀ
ꢄꢉꢀ
)ꢆ6ꢌꢈꢅ(7#'9ꢀ %1/24'5514ꢀ
)41//'6ꢀ+51.#614ꢀ
$.&%ꢀ+08'46'4ꢀ
04ꢀ
ꢄꢉꢋꢄꢀ
ꢄꢇꢀ
&$ꢈꢉꢋꢅꢅꢊꢈꢉ#ꢀ
&$ꢍꢈꢋꢅꢍꢌꢉꢅ#ꢀ
&$ꢍꢈꢋꢅꢍꢌꢉꢈ$ꢀ
&$ꢍꢉꢋꢅꢂꢈꢍꢊ$ꢀ
&$ꢍꢉꢋꢅꢂꢊꢅꢅ$ꢀ
&$ꢈꢄꢋꢅꢌꢍꢊꢇ%ꢀ
&$ꢈꢌꢋꢅꢂꢉꢄꢂ#ꢀ
&$ꢍꢉꢋꢅꢇꢊꢇꢂ&ꢀ
&$ꢈꢄꢋꢅꢌꢍꢊꢉ%ꢀ
&$ꢊꢅꢋꢅꢅꢍꢄꢅ#ꢀ
&$ꢈꢂꢋꢅꢅꢄꢆꢄ&ꢀ
&$ꢈꢂꢋꢅꢅꢄꢆꢄ(ꢀ
&$ꢍꢂꢋꢅꢄꢄꢆꢅ#ꢀ
&$ꢍꢉꢋꢅꢈꢌꢍꢅ#ꢀ
&$ꢌꢊꢋꢅꢅꢅꢇꢉ#ꢀ
&$ꢉꢌꢋꢅꢅꢄꢊꢂ$ꢀ
&$ꢉꢌꢋꢅꢅꢄꢊꢈ%ꢀ
50#ꢀ
50#ꢀ
50#ꢀ
5#ꢀ
#55ŏ;ꢀꢇ9#;ꢀ8#.8'ꢀ
#55ŏ;ꢀ8#.8'ꢀ
#55ŏ;ꢀ
ꢄꢂꢀ
#55ŏ;ꢀ
ꢄꢈꢀ
#55ŏ;ꢀ%10641.ꢀ176ꢀ
#55ŏ;ꢀ2%$ꢀ/#+0ꢀ
#55ŏ;ꢀ
ꢄꢈꢋꢄꢀ
ꢄꢈꢋꢌꢀ
ꢄꢈꢋꢉꢀ
ꢄꢈꢋꢇꢀ
ꢄꢈꢋꢂꢀ
ꢄꢈꢋꢈꢀ
ꢄꢈꢋꢆꢀ
ꢄꢈꢋꢍꢀ
ꢄꢈꢋꢄꢅꢀ
ꢄꢈꢋꢄꢄꢀ
ꢄꢊꢀ
#55ŏ;ꢀ
5#ꢀ
%#5'ꢀ%10641.ꢀ%18'4ꢀ
*'#6ꢀ5+0-
#$5ꢀ
5#ꢀ
50#ꢀ
50#ꢀ
50#ꢀ
5%ꢀ
#55ŏ;ꢀ2%$ꢀ57$ꢀ'/+ꢀ
%#5'ꢀ%10641.ꢀ$#5'ꢀ
2.#6'ꢋ%10641.ꢀ176ꢀ
6'4/+0#.ꢀ$.1%-
#55ŏ;ꢀ
#$5ꢀ
5)%%ꢋ/ꢀ
$.-
5%ꢀ
6'4/+0#.ꢀ$.1%-
$.-
5%ꢀ
#55ŏ;ꢋ6'4/+0#.ꢀ$.1%-
#55ŏ;ꢀ2%$ꢀ57$ꢋ&+52.#;ꢀ
4'#%614ꢀ
#55ŏ;ꢀ
5%ꢀ
#55ŏ;ꢀ
5#ꢀ
ꢌꢅ#ꢃꢀꢂꢅ*\ꢀ
ꢄꢅꢉ#6ꢃꢌꢅꢇ%6$ꢀ
ꢄꢅꢉ#6ꢃꢌꢅꢇ%6$ꢀ
#66<ꢀ
5#ꢀ
ꢄꢆꢀ
6*'4/+5614ꢀ%10&ꢀ
6*'4/+5614ꢀ9+4'ꢀ176ꢁ&+5%*#4)'ꢀ
5%ꢀ
ꢄꢍꢀ
5%ꢀ
ꢌꢅꢀ
&$ꢂꢇꢋꢅꢃꢅꢄꢉ#ꢋꢋꢋꢋꢋꢋ$66<ꢋ+$1'/(ꢀ
5#ꢀ
Samsung Electronics
5-12
Download from Www.Somanuals.com. All Manuals Search And Download.
6. Wiring Diagram
6-1 Indoor Unit
■ MH✳✳✳FNCA
This Document can not be used without Samsung's authorization.
6-1
Samsung Electronics
Download from Www.Somanuals.com. All Manuals Search And Download.
&J@KKNꢂ2JEPꢂĠ?KJPꢁꢋꢀ
*%ꢀ #" Aꢀ
This Document can not be used without Samsung's authorization.
Samsung Electronics
6-2
Download from Www.Somanuals.com. All Manuals Search And Download.
6-2 Outdoor Unit
■ MH050FXCA2A
This Document can not be used without Samsung's authorization.
6-3
Samsung Electronics
Download from Www.Somanuals.com. All Manuals Search And Download.
Wiring Diagram
■ MH080FXCA4A
This Document can not be used without Samsung's authorization.
Samsung Electronics
6-4
Download from Www.Somanuals.com. All Manuals Search And Download.
7. Schematic Diagram
7-1 Indoor Unit
■ MH✳✳✳FNCA
This Document can not be used without Samsung's authorization.
7-1
Samsung Electronics
Download from Www.Somanuals.com. All Manuals Search And Download.
Schematic Diagram
■ MH✳✳✳FECA
This Document can not be used without Samsung's authorization.
Samsung Electronics
7-2
Download from Www.Somanuals.com. All Manuals Search And Download.
8. PCB Diagram
8-1 MAIN PCB(Indoor Unit)
■ MH✳✳✳FNCA
The red number connecter is not used.
!ꢀ
@ꢀ
#ꢀ
$ꢀ
%ꢀ
^ꢀ
Power
&ꢀ
*ꢀ
(ꢀ
)ꢀ
1ꢀ
2ꢀ
Temperature Sensor
Motor RPM Feedback
Remocon Module
Humidity Sensor
Anions
Auto Grill
HVPS(High voltage Generator)
BLADE-H Step Motor
Display
MPI
Indoor Fan Motor
8-1
Samsung Electronics
Download from Www.Somanuals.com. All Manuals Search And Download.
02ꢌꢂ- ꢌĠ&J@KKNꢂ2JEPꢋꢂĠ?KJPꢁꢋꢀ
■ MH✳✳✳FNCA
The red number connecter is not used.
!ꢀ
@ꢀ
!ꢀ
External Signal
MAIN PCB Connection
@ꢀ
Samsung Electronics
8-2
Download from Www.Somanuals.com. All Manuals Search And Download.
PCB Diagram
■ MH✳✳✳FECA
!ꢀ
@ꢀ 4ꢀ#ꢀ $ꢀ(%ꢀ ^ꢀ
&ꢀ
*ꢀ
)ꢀ
5ꢀ
1ꢀ
2ꢀ
6ꢀ
3ꢀ
7ꢀ
8ꢀ
9ꢀ
0ꢀ
“ꢀ
‘
+
=
Qꢀ
Float Switch
COM 2
!ꢀ
3ꢀ
4ꢀ
5ꢀ
6ꢀ
7ꢀ
8ꢀ
9ꢀ
0ꢀ
“ꢀ
‘ꢀ
+ꢀ
=ꢀ
Qꢀ
Room Temperature
EVA in Temperature
EVA out Temperature
Heater Temperature
Load Control Signal
Heater
@ꢀ
Address Switch
Option Switch
Fan (Tap Control)
Ventilator
#ꢀ
$ꢀ
%ꢀ
^ꢀ
&ꢀ
*ꢀ
(ꢀ
)ꢀ
1ꢀ
2ꢀ
Wired Remote Controller Power(12V)
Control Signal
EEV
Drain Pump
Hot Coil
Display
Operating Check Signal
HALL IC
Fan (SSR)
Trans In
Download
COM 1
Main Power
Trans out
8-3
Samsung Electronics
Download from Www.Somanuals.com. All Manuals Search And Download.
ꢍꢄꢈꢂ*ꢃ&+ꢀ- ꢌĠ,QP@KKNꢂ2JEPꢋꢀ
*%ꢇꢆꢇ#5 ꢃꢈꢃꢊ*%ꢇꢍꢇ#5 ꢃꢎꢃꢀ
6JGꢀTGFꢀPWODGTꢀEQPPGEVGTꢀKUꢀPQVꢀWUGFꢐꢀ
ꢆꢀ
ꢃꢀ
2QYGTꢀ0ꢀ
%10&ꢁ1.2ꢀ6GORGTCVWTGꢀ5GPUQTꢀ
ꢈꢀ
ꢅꢀ
ꢉꢀ
2QYGTꢀ.ꢀ
&+5ꢁ176ꢀ6GORGTCVWTGꢀ5GPUQTꢀ
''8ꢀ%QPPGEVQTꢀ
ꢀꢀ
$.&%ꢀ(#0ꢀ
#%ꢀ(#0ꢀ
ꢊꢀ
ꢆꢀ
ꢃꢀ
%QORꢐꢀ%QPPGEVQTꢀ9KTGꢀ
4GCEVQTꢀ%QPPGEVQTꢀ9KTGꢀ
ꢂꢀ
ꢅꢇꢀ
%QOOWPKECVKQPꢀꢇꢆꢂꢀ
ꢄꢀ
5COUWPIꢀ'NGEVTQPKEUꢀ
ꢆꢋꢇꢀ
Download from Www.Somanuals.com. All Manuals Search And Download.
9. Troubleshooting
9-1 Items to be checked first
1. The input voltage should be rating voltage 10% range.
The air conditioner may not operate properly if the voltage is out of this range.
2. Is the link cable linking the indoor unit and the outdoor unit linked properly?
The indoor unit and the outdoor unit shall be linked by 4 wires.
2 wires are for power and other 2 wires are for communication, total 4 wires on each indoor unit. Check the terminals if the
indoor unit and outdoor unit are properly linked by the same number of cables and if connecting position on the terminal is
correct. Otherwise the air conditioner may not operate properly.
3. When a problem occurs due to the contents illustrated in the table below it is a symptom not related to the malfunction of the
air conditioner.
No
Operation of air conditioner
Explanation
In a COOL operation mode, the compressor does not
operate at a room temperature higher than the setting
temperature that the INDOOR FAN should operate.
In a HEAT operation mode, the compressor does not
operate at a room temperature lower than the setting
temperature that indoor fan should operate.
In happens after a delay of 3 minutes when the compressor
is reoperated. The same phenomenon occurs when a power
is on.
1
As a phenomenon that the compressor is reoperated after a
delay of 3 minutes, the indoor fan is adjusted automatically with
reference to a temperature of the air blew
2
Fan speed setting is not allowed in AUTO(
DRY( ) mode.
) or
The speed of the indoor fan is set to LL in DRY mode.
Fan speed is 5 steps and is selected automatically in AUTO
mode.
3
4
Compressor stops operation intermittently in
DRY( ) mode.
Compressor operation is controlled automatically in DRY mode
depending on the room temperature and humidity.
Compressor of the outdoor unit is operating although
it is turned off in a HEAT mode.
When the unit is turned off while de-ice is activated, the
compressor continues operation for up to 12 minutes (maxi-
mum) until the deice is completed.
Timer LED(
) only of the indoor unit lights up and
Timer is being activated and the unit is in ready mode.
5
6
the air conditioner does not operate.
The unit operates normally if the timer operation is cancelled.
The compressor and indoor fan stop intermittently in
HEAT mode.
The compressor and indoor fan stop intermittently if room
temperature exceeds a setting temperature in order to protect
the compressor from overheated air in a HEAT mode.
7
8
Indoor fan and outdoor fan stop operation
intermittently in a HEAT mode.
The compressor operates in a reverse cycle to remove
exterior ice in a HEAT mode, and indoor fan and outdoor fan
do not operate intermittently for within 20% of the total heater
operation.
The compressor stops intermittently in a
COOL mode or DRY mode, and fan speed of the
indoor unit decreases.
The compressor stops intermittently or the fan speed of the
indoor unit decreases to prevent inside/outside air frozen
depending on the inside/outside air temperature.
9-1
Samsung Electronics
Download from Www.Somanuals.com. All Manuals Search And Download.
9-2 Checking and Testing operations
To complete the installation, perform the following checks and tests to ensure that the air conditioner is operating
correctly.
1. Review all the following elements in the installation:
• Installation site strength
• Piping connection tightness not to leak any gas
• Connection wiring
• Heat-resistant insulation of the piping
• Drainage
• Earthing wire connection
• Setting number of the indoor unit installed (Outdoor unit SW)
• Setting SW02 for addressing mode (AUTO or MANUAL)
• Address number on each indoor unit (Manual addressing mode)
• Correct operation for pipe checking connection (follow the step below)
• If the auto addressing, refer to next page.
• If the manual addressing, please do cool mode try-run or heat mode try-run.(refer to below)
■ Settings of PCB Display of the Outdoor unit
-K1 :pipe checking operation button -K2 :Function button
-K3 :Reset button
-K4 :View mode change button
Key
K1
K2
K3
K4
Push
Heat Mode Try
run
Pipe Checking
Operation
1
SW02
SW01
(Display:
)
(Display:
)
K 1
Refrigerantꢀ
Chargingꢀ
Switch
DIS01
DIS02
2
3
4
-
(Display:
)
View mode
change
Indoor unit
address
Reset
Cool Mode Try
run
(Display:
-
-
)
K 2
K 3
K 4
Pump down
(Display:
View data display
)
Outdoor PCB Display
K4 View mode Display changes
Push
Display Explanation
Present Compressor Frequency
Push
Display Explanation
0
8
Discharge temperature
1
2
3
4
5
6
7
Target Compressor Frequency
Order Compressor Frequency
EEV0 current step
9
OLP temperature
10
11
12
13
14
15
Condenser temperature
Outdoor temperature
First current
EEV1 current step
EEV2 current step
Target Discharge temperature
Total capacity of the indoor units
Safety control
EEV3 current step
Fan RPM (H:high,L:low,Blank:off )
• The EEV 2 and EEV 3 of MH050FXCA2A model is always displayed as blank.
Samsung Electronics
9-2
Download from Www.Somanuals.com. All Manuals Search And Download.
Troubleshooting
2. Apply the power to the outdoor unit.
Outdoor unit will try to communicate the number of indoor units specifiedꢀby SW01 on outdoor display PCB.
Does LED show "Normal display"?
OK : This number is displayed
Yes
"Normal display" means, right 2 digit of
LED on Display PCB displays '00' and
left 2 digit of LED displays indoor unit
address number.
only while communicating,
so each number is displayed
for a short time in order.
Nꢀoꢀ
No
'' ''
Is error code started with
Nothing is displayed on the LED.
displayed on the LED?
Yes
Check the power source,
power cable & FUSE on
the outdoor unit.
Check the indoor unit, outdoor unit or wiring
according the error code table.
■ Pipe Checking Operation (Auto Addressing Mode)
Automated checking of pipe connection (Auto addressing option)
• Turn on the outdoor unit and wait for one minute.
During these 60 seconds,the left display DIS01 will show sequentially
00-01-02-03-...15-00.
• E199 is showed on the display PCB of outdoor unit.
-It means you didn’t do “Pipe check operation “
• Push [K1 ] button on the display PCB of outdoor unit once, then begins to start “Pipe check operation ”
with displaying as below.
Button [K1] times
DIS 01
DIS 02
Display
[DIS 01 ] is flickering on the setting time.
Outdoor Temperature
32˚F or more
(Cool mode)
5min~10min
less tha 32˚F
Time duration
(Heat mode)
20min~50min
9-3
Samsung Electronics
Download from Www.Somanuals.com. All Manuals Search And Download.
Troubleshooting
✳ Expected time of 4 indoor units installation.
• [DIS02 ] shows the indoor unit under searching
• It could take more time depending on the indoor and outdoor temperature.
• After completeing pipe check operation,it shows “ “ on the display PCB.
• The left display DIS01 will show sequentially the following message:
00 -Estabilished communication with indoor unit “A ”;
01 -Estabilished communication with indoor unit “B ”;
02 -Estabilished communication with indoor unit “C ”;
03 -Estabilished communication with indoor unit “D ”;
00 -Estabilished communication with indoor unit “A ”...
• Function of Step 3
Mode
Function
Auto Addressing
Checking the connection & addressing
Manaul Addressing
Checking the connection only
- If the auto addressing does not work according to the indoor unit capacity, model or installation condition,apply the manual
addressing.
✳ When SW01 set "0"on Auto address mode,it means you install the maximum number of indoor unit.
1) Installation ID Unit Number=MAX Installation ID Unit Number of OD Unit.
➟ Don't need set SW01.
2) Installation ID Unit Number<MAX Installation ID Unit Number of OD Unit.
➟ Pls set SW01 as the number of which you install the indoor unit.
✳ On Manual address mode,you must set SW01 as the number of which you install the indoor unit.
- This mode is for finding the combination between indoor unit and each valve on the outdoor unit. Because refrigerant flow is
controlled with EEV in the outdoor, controller should know which EEV will control which indoor unit.
- Once "PIPE CHECK MODE" is done normally, each indoor unit will remember the given address number by the outdoor unit
and no need to do this checking. But in case of listed below, PIPE CHECK MODE should be done again.
• Re-install the system (ie.house moving)
• Remove indoor unit, Add new indoor unit, Change indoor PCB for repair.
• Mode change from "manual addressing" to "auto addressing"
- On this mode the controller will ignore the manual address number set on the rotary switch on the indoor PCB.
- To confirm the indoor address number assigned by this mode, use "TEST MODE" and the address number will be displayed on
the LED display on the indoor unit.
Samsung Electronics
9-4
Download from Www.Somanuals.com. All Manuals Search And Download.
Troubleshooting
■ In case of MANUAL ADDRESSING mode.
Switch Setting and Testing Operation
To complete the installation, perform the following checks and tests to ensure that the air conditioner is operating correctly.
Step 1
Review all the following elements in the installation:
• Installation site strength
• Piping connection tightness to detect any gas leakage
• Connection wiring
• Heat-resistant insulation of the piping
• Drainage
• Earthing wire connection
Step 2
IMPORTANT!
Before selecting switch turn off the system power supply
- Select rotary switch “SW01 ” of outdoor unit display PCB,according to number
of indoor unit connected:
Switch
ex) connecting with ex) connecting with
Indoor unit
address
2 indoor units.
2 indoor units.
Views data display
Advise control we are going to proceeed
with manual addressing as follow:
SW02
-Move dip switch n°1 of “SW02
-outdoor unit display PCB ” down;
Manual
addressing
Switch
Indoor unit
address
Move down the switch nß1
Views data display
Step 3
Step 4
Follow of indication reported into table below for indoor unit addressing
Turn on the system power supply and waiting for 60 seconds after estabilishing communication between outdoor and
indoor units.
During this phase,the left display of outdoor unit display PCB “DIS01 ” will count fom 00--01--02 to 15.
Estabilished communication the left display will count sequentially:
00--communication with indoor unit A;
01--communication with indoor unit B;
02--communication with indoor unit C;
03--communication with indoor unit D;
✳ In case of Manual address mode,you can do pipe check operation for check whether you connect the pipes correctly or not.
But you need set indoor address switch yourselves.
9-5
Samsung Electronics
Download from Www.Somanuals.com. All Manuals Search And Download.
Troubleshooting
Switch Setting and Testing Operation (cont.)
TO SET ADDRESSING MANUALLY BY ROTARY
SWITCH “SW02 ”
TYPE
PICTURE
MODEL
MH026FNCA
MH035FNCA
MH052FNCA
RAC
MH026FECA
MH035FECA
MH052FECA
SLIM DUCT
Samsung Electronics
9-6
Download from Www.Somanuals.com. All Manuals Search And Download.
Troubleshooting
Switch Setting and Testing Operation (cont.)
ROTARY SWITCH “SW02 ” POSITION ACCORDING TO REFRIGERANT CIRCUIT
CONNECTED (0=A;1=B;2=C;3=D )
INSTALLATION TEST MODE (with all indoor units functioning)
Please do cool mode try-run or heat mode try run.
Cool mode try-run :Push the [K2 ] button three times.
Heat mode try-run :Push the [K2 ] button once.
After 12 minutes of stationary condition check each indoor unit air treatment:
Cooling mode (indoor unit check) →ꢀInlet air temp.-Outlet air temp : From 10°K to 12°K (indicative delta T)
Heating mode (indoor unit check) →ꢀOutlet air temp.-Inlet air temp : From 11°K to 14°K (indicative delta T)
In heating mode,the indoor fan motor can remain off to avoid cold air blown into conditioned space.
9-7
Samsung Electronics
Download from Www.Somanuals.com. All Manuals Search And Download.
Troubleshooting
● If Error code is displayed on indoor or outdoor LED, check as follows;
- Manaul address setting
Contents
Q1
Turn on the system. But outdoor units PCB displayed E201 or E101 Error code.
Check point
Remarks
Outdoor PCB
SW01
Step 1
Step 2
Check to Number of indoor unit’s SW01.
Check to power cable to indoor units.
Check to communication cable indoor units.
Wire connect
Contents
Turn on the system. But outdoor units PCB displayed E203 Error code.
Check point
Q2
Remarks
Outdoor communication error between the outdoor main
PCB and sub PCB.
.Outdoor PCB
SW01
Step 1
Step 2
Check to sub PCB wire and replace it.
Wirre connect
Contents
Turn on the system. But indoor unit displayed E121/122/123/154 Error
Explanation
Q2
Error code
E121
Indoor unit room temperature sensor error (open/short)
Indoor unit heat exchanger in temperature sensor error (open/short)
Indoor unit heat exchanger out temperature sensor error (open/short)
Indoor unite fan error
E122
E123
E154
Please, all units turn off and check to indoor unit’s PCB and wire connection. E121/122/123 error detected, replace
related sensor.
Guicance
Contents
Turn on the system. But indoor unit displayed E162/163 Error code.
Explanation
Q4
Error code
E162
Indoor unit EEPROM Error.
Indoor unit EEPROM Option Error.
E163
Please, all units turn off and follow guidance.
E163 : Please reset indoor Option code.
Guidance
If you don’t know about that, replace indoor unit PCB which is related.
E162 : Please replace indoor unit PCB which is related.
Contents
Turn on the system. But outdoor unit displayed E221/237/251/320 Error
Explanation
Q5
Error code
E221
Outside temperature sensor error (open/short)
Indoor unit heat exchanger in temperature sensor error (open/short)
Condenser temperature sensor error (open/short)
Compressor Discharge temperature sensor error (open/short)
Compressor OLP sensor error (open/short)
E237
E251
E251
E230
Please, The System turn off and replace sensor which is related.
Guidance
Samsung Electronics
9-8
Download from Www.Somanuals.com. All Manuals Search And Download.
Troubleshooting
Contents
Q1
Indoor units address SW setting correct, but outdoor unit’s PCB displayed E201 Error Code.
Check point
Remarks
Indoor unit’s sub PCB address SW or sub PCB is
connected by mistake.
Analysis
Step 1
Check to indoor unit’s sub PCB wire connecting
condition.(misconnecting or Sub PCB is out of order)
Indoor
Sub PCB
Step 2
Address setting mode change to auto address setting.
Following auto address setting steps.
Step 3
Manual Address setting is Option in FJM PLUS A.
But we solved problem like this situation, with auto address setting.
Guidance
- Auto address setting
Contents
When the pipe checking operation is finished, outdoor sub PCB display E190 Error code.
Q1
Check point
Remarks
Outdoor unit fails to search indoor units or to check
indoor address.
Analysis
Step 1
The pipe checking operation
Pipe connecting
EEV Coil
Whether The gas and liquid pipes are crossed with
each other, check to connecting.
Check to outdoor unit’s EEV coil being connected in
proper location.
Step 2
Check to indoor unit’s sensor being connected in
proper location.
Step 3
Indoor sensor
During the pipe checking operation , system check temperature change of indoor Heat exchanger.In case, indoor
sensor defect, EEV coil connector detach, malfunction of EEV, Leakage of Refrigerant, and etc can make this case.
Guidance
- Address setting another case
Contents
When the pipe checking operation is finished, outdoor sub PCB display E190 Error code.
Q1
Check point
Remarks
Outdoor unit fails to search indoor units or to check
indoor address.
Analysis
Step 1
The pipe checking operation
Pipe connecting
EEV Coil
Whether The gas and liquid pipes are crossed with
each other, check to connecting.
Check to outdoor unit’s EEV coil being connected in
proper location.
Step 2
Check to indoor unit’s sensor being connected in
proper location.
Step 3
Indoor sensor
During the pipe checking operation , system check temperature change of indoor Heat exchanger.In case, indoor
sensor defect, EEV coil connector detach, malfunction of EEV, Leakage of Refrigerant, and etc can make this case.
Guidance
9-9
Samsung Electronics
Download from Www.Somanuals.com. All Manuals Search And Download.
Troubleshooting
- Operation case
Contents
Q1
While using cooling or heating, indoor units display E161 Error code
Check point
Remarks
This problem is caused by user’s fault. User’s simultaneously operate 2 more indoor units in the same time cooling
and heating mode.
Analysis
Guidance
FJM is operate by just cooling or heating mode only. (Only, HR system can operate cooling and heating mode
simultaneously in the same time)
Outdoor unit will be operate by first received signal, another operation signal is not applied system.
Contents
Q2
While using cooling or heating, System turn off and display E416 Error code.
Check point
Remarks
E416 is outdoor unit high discharge temperature safety control Error code.
After System restart automatically until 3 times, system stop and display this error.
System can be operated by remote controller signal and K3(reset) key input.
Analysis
Check outdoor units installation environment.
(air flow blocking, the halation of another outdoor air flow)
Step 1
Step 2
Step 3
Check refrigerant leakage.
Check outdoor EEV operation.
Contents
While using cooling or heating, System Turn off and display E458 Error code
Check point
Q3
Remarks
E458 Error is related with outdoor unit fan Error.
Analysis
Especially, If system have a some problem in fan, in heating mode , it will be happened.
And In auto address setting, without pipe checking operation must be happened it.
Step 1
Step 2
Check to outdoor fan operation.
If outdoor fan operation is clear, start to pipe checking operation.
When Auto address setting is finished without pipe checking operation, in heating mode, outdoor unit refrigerant
distribution control is malfunction.
It make our system to confuse it’s condition.
Guidance
But, basically this error code is concerned about fan error.
Contents
Q4
While using cooling mode, outdoor unit turn off and display E401 Error code.
Check point
Remarks
This is caused by protection mode behavior.
This is indoor Evaporator Freezing protection mode.
Analysis
Step 1
Step 2
Please, check indoor unit, whether inlet or outlet grill is closed.
Please, check indoor unit, whether indoor fan is working.
Samsung Electronics
9-10
Download from Www.Somanuals.com. All Manuals Search And Download.
Troubleshooting
Contents
Q5
When system start in cooling mode, System don’t operate and display E441 Error code
Check point
Remarks
FJM PLUS is able to operate by -10˚C
But we admit that minimum Cooling temperature is by -5˚C
Please, Remember cooling operation range.
Analysis
Contents
While using heating, outdoor unit turn off and display E404 Error code.
Check point
Q6
Remarks
Heating overload safety mode make this situation.
After System restart automatically until 3 times, System display this error code and stop.
System can operate by remote controller input signal or K3(reset) key input.
Analysis
Step 1
Step 2
Check indoor units air flow.
Check outdoor unit air flow and installation (outdoor air flow blocking & over charging)
Contents
Q7
When system start in Heating mode, System don’t operate and display E440 Error code.
Check point
Remarks
FJM PLUS is able to operate up to 30˚C
But we admit that Maximum Heating temperature is up to 24˚C
Please, Remember Heating operation range.
Analysis
- Try-run Check Error
Contents
While the system is working try-run mode, system turn off and display E128 / 129 / 246 / 261 / 419 / 422 / 554
Error code.
Q8
Check point
Remarks
These Error codes only apply with Try-run mode, in case of system have some defect as result of try-run operation.
✳ Refer to self-detection algorithm (Check Error Code meaning and check it out)
Analysis
9-11
Samsung Electronics
Download from Www.Somanuals.com. All Manuals Search And Download.
9-3 Fault Diagnosis by Symptom
9-3-1 Basic Check Flow
Preparation : multimeter (AC voltage, DC voltage, Resistance)
START
Check point
Short check
for safety
Detach cable cover of the terminal blocks
(HANDLE CABI RH) on outdoor unit.
No Good
• Outdoor unit controller (see 12-3-2)
• Indoor unit controller (see 12-3-3)
Check resistance value between
L and N of Main power terminal block.
OK : over 180KΩꢀ
Apply the power
Power Source
check
No Good
No Good
• Power cable (see 12-3-4, 12-2)
• Breaker
Check AC voltage between L and N of
MAIN power terminal block.
OK : 207-253V(50Hz)
Check AC voltage between L and N of
power terminal block for indoor unit.
Terminal block wiring
OK : 207-253V
Is there any display of LED?
Yes
Outdoor unit
• Main PCB,
• Display PCB,
• wiring between PCBs.
No
No Good
Starting by remocon or ON/OFF switch on the indoor
unit or K2 button on the Outdoor PCB display.
Start operation
Yes
Error code starts in '' ''
Any Error code on LED display?
Wait for 5 minutes to check error
code because some error judgement
needs long time.
Consult error code table
No
• Remote control
• Remote control battery
• Infrared signal receiving path
(front panel duct, infrared receiving module, wiring)
No
No
Receiving of remote control signal ?
(Check by buzzer sound)
Indoor unit
Yes
Check operation ON/OFF by the button
at lower right of the display module
(By buzzer sound and LED display)
• Indoor unit,
• Wiring cable to outdoor unit
Yes
Error code starts in '' ''.
Error code consists of 4 digits and displays first 2
digit and last 2 digit alternatively.
Ok
Any Error code on LED display?
Wait for 5 minutes to check error code
because some error judgement
needs long time
Consult error code table
Check Major parts(See 12-5)
Consult error code(Next Page)
Samsung Electronics
9-12
Download from Www.Somanuals.com. All Manuals Search And Download.
Troubleshooting
Basic Check Flow(cont.)
Preparation : multimeter (AC voltage, DC voltage, Resistance)
Consult Error Code
Check point
,
,
,
,
,
• Cable wiring between indoor and outdoor
• Communication wire socket check on
outdoor unit controller PCB
Is the error code related to
communication ?
No
,
• Cycle check
• Pipe matching
Is the error code related to
cycle protection ?
No
,
,
Are some of the indoor units’
operation mode (cooling/heating)
different from others ?
Each indoor unit operation mode
No
--
,
Error related to outdoor controller except
temperature sensor and communication
between indoor unit and outdoor unit ?
Consult LED pattern on wiring diagram on
outdoor controller
No
See Error Code Table and Check
“Main checking point”
9-13
Samsung Electronics
Download from Www.Somanuals.com. All Manuals Search And Download.
Troubleshooting
9-3-2 Checking Outdoor Controller
1. Making sure the wire connections.
2. Checking AC line
1) Checking FUSE
2) Checking resistance between 'L wire (SKY BLU)' and 'BD01
Neutral' normal value : 190 - 210Ωꢀ
If value is ∞ꢀthen check R001.
Live
Neutral
3) Checking resistance between 'N wire (BRN)' and 'BD01 Live side'
normal value : 0 - 0.1Ωꢀ
3. Checking ON/OFF pattern of LED1(Red), LED2(Green), LED3(Yellow)
Apply the power then ALL LEDs are on for about 1 second. then changed to as follow.
■ LED1 (Red) : ALWAYS ON
■ LED2 (Green) : Blinking 4 times a second
(This means communication between 2 micoms IC01 and IC50 is normal)
■ LED3 (Yellow) : OFF
● In case of another pattern inverter micom detects some hardware trouble or abnormal condition.
Yellow
Green
Red
Description
Note
Status indication
OFF
ON
OFF
ON
OFF
ON
Power OFF / No power (SMPS error)
Power on reset ( 1~2 seconds )
Normal operation
If always in this pattern IC01(inverter micom)
has some trouble.
OFF
Blink
ON
Hardware trouble
Communication Error between
Main micom and inverter micom
OFF
OFF
ON
Blink
ON
Blink
Blink
ON
Current sensor error
DC-LINK sensor error
Blink
AC-Line zero crossing error
After power off this error will display until
ON
ON
ON
Blink
Blink
DC LINK capacitor discharged.(Max 20sec.)
OFF
Option error (EEPROM error)
Abnormal condition
OFF
OFF
ON
OFF
Blink
OFF
ON
Blink
OFF
ON
Comp. peak current (Over Current)
Comp. starting error
Comp. rotation error
OFF
Blink
Blink
OFF
DC-Link voltage error
Comp. V Limit Error
ON
Samsung Electronics
9-14
Download from Www.Somanuals.com. All Manuals Search And Download.
Troubleshooting
4. Checking Display PCB LED if Error code is displayed.
See error code table if displayed.
5. Checking DC voltage on each point
Item
Measuring point
Normal value
about 1.4 times as much as Power AC Voltage
DC LINK
Q803 E(-)~D101 Cathode (+)
ex) AC220V → 305~310Vdc
inverter 15V
Main control 12V
Main control 5V
C803 voltage
14.5V~15.5V
12V~15V
CN59 pin 1~pin 3
CN59 pin 1~pin 2
4.75V~5.25V
6. Checking PFC
When Input current is over 2.8A PFC circuit will work to control the harmonics of AC current.
Checking is measuring DC-LINK voltage.
PFC ON (Compressor is working) : DC LINK voltage is over 300Vdc (AC line >220V )
After starting compressor DC Link voltage is going down because of compressor load.
But in case of 2.8A above , DC link voltage will go up over 300V. This voltage is in proportion to AC input voltage.
Current can be monitored with "VIEW MODE".
Press K4 key on the outdoor display PCB for several times to change the display to sensor temperature value.
Left 1 digit of the LED is data index and Right 3 digits are the value
Index
Value
Remark
Estimated Primary current value from
Compressor current
C
The unit is 0.1A
9-15
Samsung Electronics
Download from Www.Somanuals.com. All Manuals Search And Download.
Troubleshooting
9-3-3 Checking Indoor controller
9-3-4 Checking Power cable and Communication cable
See 12-2 "Checking and Testing operations" and installation manual.
9-3-5 Checking Temperature sensor
See 12-5 "Fault Diagnosis of Major Parts".
In case of a sensor in outdoor unit, temperature can be monitored with "VIEW MODE".
Press K4 key on the outdoor display PCB for several time to change the display to sensor temperature value.
Left 1 digit of the LED is data index and Right 2 digits are the value.
Index
Value
Discharge sensor temperature
Remark
8
9
OLP sensor temperature
The unit is degree C
A
B
Condenser sensor temperature
Outdoor sensor temperature
Samsung Electronics
9-16
Download from Www.Somanuals.com. All Manuals Search And Download.
Troubleshooting
ꢏꢄꢀꢄꢉꢂ DA?GEJCꢂ""3ꢀ
5GGꢀꢄꢌꢋꢂꢀꢔ(CWNVꢀ&KCIPQUKUꢀQHꢀ/CLQTꢀ2CTVUꢔꢐꢀ
%WTTGPVꢀ''8ꢀUVGRꢀXCNWGꢀECPꢀOQPKVQTGFꢀYKVJꢀꢔ8+'9ꢀ/1&'ꢔꢀ
2TGUUꢀ-ꢇꢀMG[ꢀQPꢀVJGꢀQWVFQQTꢀFKURNC[ꢀ2%$ꢀHQTꢀUGXGTCNꢀVKOGꢀVQꢀEJCPIGꢀVJGꢀFKURNC[ꢀVQꢀEWTTGPVꢀ''8ꢀXCNWGꢐꢀ
.GHVꢀꢄꢀFKIKVꢀQHꢀVJGꢀ.'&ꢀKUꢀFCVCꢀKPFGZꢀCPFꢀ4KIJVꢀꢉꢀFKIKVUꢀKUꢀVJGꢀXCNWGꢐꢀ
Index
Value
Remark
3
4
5
6
EEV-A step
EEV-B step
EEV-C step
EEV-D step
The step value range is
between Zero and 480.
ꢏꢄꢀꢄꢐꢂ-ELAꢂI=P?DEJCꢀ
5GGꢀꢂꢋꢌꢀꢔ%JGEMKPIꢀCPFꢀ6GUVKPIꢀQRGTCVKQPUꢔꢐꢀ
9-17
Samsung Electronics
Download from Www.Somanuals.com. All Manuals Search And Download.
9-4 PCB Inspection
9-4-1 Cautions for Part Replacement
1. The human body carries much static electricity.
Before touching a part for repair, replacement or the
similar purpose, be sure to touch a grounded metal-
lic portion by hand to let the static electricity go
through the metallic portion to the earth.
Especially when handling any micro computer or IC,
carefully remove such static electricity before touch-
ing them.
6. When soldering any part, care should be exercised
not to apply any high-wattage soldering iron to the
part for a long time. Some parts are of so low a heat
resistance that they may be broken or have the
properties changed if a soldering iron is so applied
(Otherwise, the pattern may possibly be separated
and raised).
7. The heat of the soldering iron should be transferred
to the entire object to be soldered. If the solder
pieces are not well fused due to insufficient transfer
of the heat from the soldering iron, no satisfactory
electrical continuity can be assured even if the sol-
dered objects appear well connected to each other.
2. When repairing any part on a work bench, be sure
to place an insulative sheet on the bench and always
keep the sheet surface neat without any metal frag-
ments. If any such fragment touches a part, a sec-
ondary trouble will possibly be caused in the part.
3. Before replacing any parts, be sure to turn off the
power supply. If such replacement is done with the
power supply kept on, an electric shock, short circuit
or destruction of a part may result.
8. The solder used should be limited to a minimum.
If excessive solder is used, it will cause inter-pattern
contact, which may cause malfunction of the circuit.
9. Although some part of the PCB surface are coated
with coating material for protection from dust and
dirt, soldering is also available to the coating part.
Because this coating is thin and is weak for solder-
ing heat.
4. During replacement or repair of a part, carefully han-
dle it : The printed circuit board has fine lead wires
(jumper wires) and glass-made parts (diode) on its
substrate.
So if a circuit board is roughly handled, such lead
wires and parts will be easily broken or damaged by
bending or shock.
But coating material remaining on the solder part
should be cleaned up before soldering a new
component to prevent the solder part from becoming
bad conduction.
5. When soldering the lead wires of any new part, be
sure to polish them using an emery paper or the like
before soldering them.
Since the lead wires of any new part are covered
with an oxide film, solder cannot adhere to the lead
wires if not polished.
9-4-2 Procedure
The parts should be replaced in the following procedure.
Check for any faulty part.
Detach the faulty part.
Replace it with a new part.
Check the operation of the new part.
The repair is completed.
Samsung Electronics
9-18
Download from Www.Somanuals.com. All Manuals Search And Download.
10. Reference for Installation
10-1 Selecting Area for Installation
Select an area for installation that is suitable to customer’s needs.
10-1-1 Indoor Unit
1. Make sure that you install the indoor unit in an area providing good ventilation.
It must not be blocked by an obstacle affecting the airflow near the air inlet and the air outlet.
2. Make sure that you install the indoor unit in an area allowing good air handling and endurance of vibration of the indoor unit.
3. Make sure that you install the indoor unit in an area where there is no source of heat or vapor nearby.
4. Make sure that you install the indoor unit in an area from which hot or cool air is spread evenly in a room.
5. Make sure that you install the indoor unit in an area away from TVs, audio units, cordless phones, fluorescent lighting fixtures
and other electrical appliances (at least 3.3ft).
6. Make sure that you install the indoor unit in an area which provides easy pipe connection with the outdoor unit, and easy
drainage for condensed water.
7. Make sure that you install the indoor unit in an area which is large enough to accommodate the measurements shown in
figure on the next page.
• It is harmful to the air conditioner if it is used in the following environments: greasy areas (including areas
near machines), salty areas such as coast areas, areas where sulfuric gas is present such as hot spring
areas. Contact your dealer for advice.
10-1
Samsung Electronics
Download from Www.Somanuals.com. All Manuals Search And Download.
Reference for Installation
10-1-2 Outdoor Unit
1. Make sure that you install the outdoor unit in area not exposed to the rain or direct sun light.(Install a separate sunblind if
exposed to direct sun light.)
2. Make sure that you install the outdoor unit in area allowing the good air moment, not amplifying noise or vibration, especially
to avoid disturbing neighbors. (Fix the unit firmly if it is mounted in a high place.)
3. Make sure that you install the outdoor unit in area providing the good ventilation and which is not dusty. It must not be
blocked by any obstacle affecting the airflow near the air inlet and the air outlet.
4. Make sure that you install the outdoor unit in area free from animals or plants.
5. Make sure that you install the outdoor unit in area not blocking the traffic.
6. Make sure that you install the outdoor unit in area easy to drain condensed water from the indoor unit.
7. Make sure that you install the outdoor unit in area which provides easy connection within the maximum allowable length of a
coolant pipe.
If you install the excessive length of pipe, add additional refrigerant as 0.11 oz per unit ft; refer to the table below.
/QFGNꢀ
6QVCNꢄEQPPGEVKPIꢄRKRGꢄNGPIVJꢇ.ꢈꢀ
.6ŭꢈꢂꢐꢈHVꢀ
#FFKPIꢄTGHTKIGTCPVꢀ
%JCTIGNGUUꢀ
/*ꢅꢂꢅ(:%#ꢌ#ꢀ
.6 ꢈꢂꢐꢈHVꢀ
ꢎ.6ꢋꢈꢂꢐꢈHVꢏZꢅꢐꢄꢄꢀQ\ꢀ
%JCTIGNGUUꢀ
.6ŭꢄꢉꢄꢐꢌHVꢀ
/*ꢅꢆꢅ(:%#ꢇ#ꢀ
.6 ꢄꢉꢄꢐꢌHVꢀ
ꢎ.6ꢋꢄꢉꢄꢐꢌHVꢏZꢅꢐꢄꢄꢀQ\ꢀ
8. Make sure that you install the outdoor unit in an area which is large enough to accommodate the measurements shown in
figure on the next page.
10-1-3 Remote Control Unit
1. Make sure that you use the remote control unit in an area free from obstacles such as curtains etc, which may block signals
from the remote control unit.
2. Make sure that you put the remote control unit in an area not exposed to direct sunlight, and where there is no source of
heat.
3. Make sure that you use the remote control unit in an area away from TVs, audio units, cordless phones, fluorescent lighting
fixtures and other electrical appliances (at least 3.3ft).
Samsung Electronics
10-2
Download from Www.Somanuals.com. All Manuals Search And Download.
10-2 Connecting Up and Purging the Circuit
• The air in the indoor unit and in the pipe must be purged. If air remains in the refrigeration pipes, it will affect
the compressor, reduce to cooling capacity and could lead to a malfunction. Refrigerant for air purging is not
charged in the outdoor unit. Use Vacuum Pump as shown at the right figure. Each unit must be purged in turn.
■ MH050FXCA2A
1. Check the piping connections.
2. Connect the charging hose of low pressure side of manifold gauge to the
packed valve having a service port (3/8" service valve) as shown at the
figure.
3. Open the valve of the low pressure side of manifold gauge counter-
Indoor
clockwise.
A-unit
Indoor
B-unit
4. Purge the air from the system using vacuum pump for about 10 minutes.
• Close the valve of the low pressure side of manifold gauge clockwise.
• Make sure that pressure gauge show -0.1MPa(-76cmHg) after about
10 minutes.
Vacuum
Pump
• This procedure is very important in order to avoid gas leak.
• Turn off the vacuum pump
• Remove the hose of the low pressure side of manifold gauge.
5. Set valve cork of both liquid side and gas side of packed valve to the
open position.
Valve stem
Stem cap
6. Mount the valve stem nuts and the service port cap to the valve, and
tighten them at the torque of 183kgf•cm with a torque wrench.
Service port
7. Check for gas leakage.
• At this time, especially check for gas leakage from the 3 way valve’s
stem nuts, and from the service port cap.
10-3
Samsung Electronics
Download from Www.Somanuals.com. All Manuals Search And Download.
Reference for Installation
■ MH080FXCA4A
1
2
Check the piping connections.
Connect the charging hose of low pressure side of manifold gauge to the
packed valve having a service port (5/8” Packed valve)as shown at the
figure (Value stem:1/2”-20UNF).
WARNING:
Make the electrical connection and leave the system into “stand by
mode”. Do not turn on the system!.
Aꢀ
Bꢀ
Cꢀ
This is necessary for better vacuum operation (full OPEN position of
Electronic Expansion Valve -EEV -).
Vacuum
Pump
3
4
Open the valve of the low pressure side of manifold gauge ounter
clockwise.
Purge the air from the system using vacuum pump for about 30 minutes.
- Close the valve of the low pressure side of manifold gauge clockwise.
- Make sure that pressure gauge show -0.1MPa(-76cmHg)after about
30 minutes.
Valve stem
Stem cap
This procedure is very important in order to avoid gas leak.
- Turn off the vacuum pump.
- Remove the hose of the low pressure side of manifold gauge.
Service port
5
Set valve cork of both liquid side and gas side of packed valve to the
open position.
6
7
Mount the valve stem nuts and the service port cap to the valve,and
tighten them at the torque of 183kgf•cm with a torque wrench.
Check for gas leakage.
- At this time,especially check for gas leakage from the 3-way valve ’s
stem nuts,and from the service port cap.
Samsung Electronics
10-4
Download from Www.Somanuals.com. All Manuals Search And Download.
10-3 Refrigerant Refill
10-3-1 MH050FXCA2A
Refill an air conditioner with refrigerant when refrigerant has been leaked at installing or using.
1) Purge air(for new installation only).
2) Turn the 3 way valve clockwise to close,
connect the pressure gauge (low pressure side)
to the service valve, and open the 3 way valve
Suspension hook
High
pressure
gauge
Compound
gauge
again.
Hand
wheel
Finger tight
fittings
3) Connect the tank to refill with refrigerant.
Connected to
high pressure
side
For mounting
other and of
hose when
not in use
Charging line
4) Set the unit to cool operation mode.
5) Check the pressure indicated by the pressure
gauge(low pressure side).
2
* Standard pressure should be 8.0~9.0kg/cm
in a regular and high operation mode.
6) Open the refrigerant tank and fill with refrigerant
until the rated pressure is reached.
* It is recommended not to pour the refrigerant
in too quickly, but gradually while operating a
pressure valve.
7) Stop operation of the air conditioner.
8) Close the 3 way valve, disconnect the pressure
gauge, and open the 3 way valve again.
9) Close the cap of each valve.
10-5
Samsung Electronics
Download from Www.Somanuals.com. All Manuals Search And Download.
Reference for Installation
10-3-2 MH080FXCA4A
Refill an air conditioner with refrigerant when refrigerant has been leaked at installing or using.
1) Purge air(for new installation only).
2) Turn the 5/8" service valve clockwise to close,
connect the pressure gauge (low pressure side)
to the service valve, and open the 5/8" service
Suspension hook
High
pressure
gauge
Compound
gauge
valve again.
Hand
wheel
Finger tight
fittings
3) Connect the tank to refill with refrigerant.
4) Set the unit to cool operation mode.
Connected to
high pressure
side
For mounting
other and of
hose when
not in use
Charging line
5) Check the pressure indicated by the pressure
gauge(low pressure side).
2
* Standard pressure is should be 8.0~9.0kg/cm
in a regular, high operation mode.
6) Open the refrigerant tank and fill with refrigerant
until the rated pressure is reached.
* It is recommended not to pour the refrigerant
in too quickly, but gradually while operating a
pressure valve.
7) Stop operation of the air conditioner.
8) Close the 5/8" service valve, disconnect the
pressure gauge, and open the 5/8" service valve
again.
9) Close the cap of each valve.
Samsung Electronics
10-6
Download from Www.Somanuals.com. All Manuals Search And Download.
ꢅꢇꢄꢎꢂ/ABNECAN=JPꢂꢃ@FQOPIAJPꢀ
*%ꢇ5ꢇ#5CꢃꢈAꢊ*%ꢇ8ꢇ#5Cꢃ4Aꢀ
%NCUUꢀ
#VꢄUGTXKEGꢀ
#VꢄKPUVCNNCVKQPꢀ
#KTꢋ2WTIGꢀ
/GVJQFꢀ
4GHTKIGTCPVꢀ
#FLWUVOGPVꢀ
#KTꢋ2WTIGꢀ
/GVJQFꢀ
4GHTKIGTCPVꢀ
3WCPVKV[ꢀ
%QPPGEVKQPꢀ
2KRGꢀ.GPIVJꢀ
4GHGTꢀVQꢀVJGꢀ
7PPGEGUUCT[ꢀ
2WTIGꢀCKTꢀWUKPIꢀCꢀ
XCEWWOꢀRWORꢀ
QTꢀCPꢀCFFKVKQPCNꢀ
TGHTKIGTCPVꢀE[NKPFGTꢐꢀ
TGHGTꢀVQꢀ
URGEKHKECVKQPꢀUJGGVꢀ
5VCPFCTFꢀ
ꢕꢀ616#.ꢀbꢀꢌꢅOꢀ
ꢎ/*ꢅꢂꢅ(:%#ꢌ#ꢏꢀ
FGVCKNGFꢀ%QPPGEVKPIꢀWRꢀ
CPFꢀRWTIKPIꢀVJGꢀEKTEWKVꢐꢀ
ꢎꢄꢅꢋꢌꢀRCIGꢏꢀ
/CZꢐꢀ
ꢕꢀ616#.ꢀŭꢀꢇꢅOꢀ
ꢎ/*ꢅꢆꢅ(:%#ꢇ#ꢏꢀ
#FFꢀꢔꢅꢐꢄꢄQ\ꢔꢀQHꢀTGHTKIGTCPVꢀ
ꢎ4ꢇꢄꢅ#ꢏꢀHQTꢀGXGT[ꢀꢄHVꢐꢀ
#FFꢀꢔꢅꢐꢄꢄQ\ꢔꢀQHꢀTGHTKIGTCPVꢀ
ꢎ4ꢇꢄꢅ#ꢏꢀHQTꢀGXGT[ꢀꢄHVꢐꢀ
+VꢀYQWNFꢀDGꢀVJGꢀDGUVꢀEJQKEGꢀVQꢀWUGꢀVJGꢀUVCPFCTFꢀVWDGꢀNGPIVJꢀVQꢀMGGRꢀVJGꢀDCUKEꢀSWCNKV[ꢀQHꢀ4QQOꢀ#KTꢀEQPFKVKQPGTꢃꢀHQTꢀGZCORNGꢀEQQNKPIꢀ
CPFꢀJGCVKPIꢀECRCEKV[ꢃꢀUQWPFꢀNGXGNꢃꢀXKDTCVKQPꢀNGXGNꢃꢀCPFꢀTGNKCDKNKV[ꢐꢀ
$WVꢃꢀCEEQTFKPIꢀVQꢀCꢀEGTVCKPꢀFKHHGTGPVꢀKPUVCNNCVKQPꢀEQPFKVKQPꢃꢀVJGꢀEQPPGEVKQPꢀVWDGꢀNGPIVJꢀEQWNFꢀDGꢀEJCPIGFꢀKPꢀVJGꢀTGEQOOGPFCVKQPꢀ
NGPIVJꢀVJCVꢀKUꢀUJQYPꢀCDQXGꢐꢀ
+PꢀVJKUꢀECUGꢃꢀKPUVCNNGTꢀUJQWNFꢀMGGRꢀVJGꢀKPUVCNNCVKQPꢀEQPFKVKQPꢀVQꢀMGGRꢀVJGꢀSWCNKV[ꢀQHꢀ4QQOꢀ#KTꢀEQPFKVKQPGTꢐꢀ
4GHTKIGTCPVꢀUJQWNFꢀDGꢀEJCTIGFꢀCFFKVKQPCNN[ꢀCUꢀYTKVVGPꢀCDQXGꢀCEEQTFKPIꢀVQꢀVJGꢀEJCPIGꢀQHꢀVJGꢀNGPIVJꢀQHꢀVJGꢀEQPPGEVKQPꢀVWDGꢐꢀ
+VꢀPGGFUꢀVQꢀCHHGEVꢀVJGꢀFGETGCUGꢀKPꢀEQQNKPIꢀCPFꢀJGCVKPIꢀECRCEKV[ꢀQTꢀQHꢀVJGꢀTGNKCDKNKV[ꢀQHꢀEQORTGUUQTꢀVJCVꢀOC[ꢀDGꢀECWUGFꢀD[ꢀCꢀNCEMꢀQHꢀTGHTKIGTꢋꢀ
CPVꢐꢀ
+PUVCNNCVKQPꢀRQUKVKQPꢀFKHHGTGPEGꢀDGVYGGPꢀVJGꢀKPFQQTꢀWPKVꢀCPFꢀVJGꢀQWVFQQTꢀWPKVꢀUJQWNFꢀPQVꢀGZEGGFꢀQXGTꢀVJCPꢀꢇꢍꢐꢌHVꢐꢀ
9JGPꢀVJGꢀEQPPGEVKQPꢀRKRGꢀKUꢀDGGPꢀGZVGPFGFꢀNQPIGTꢀVJCPꢀꢄꢈꢐꢇHVꢃꢀKVꢀOKIJVꢀPGGFꢀVQꢀEJCPIGꢀVJGꢀFKCOGVGTꢀQHꢀVJGꢀGNGEVTKECNꢀYKTGꢀVQꢀCꢀNCTIGTꢀUK\Gꢀ
KPꢀQTFGTꢀVQꢀMGGRꢀCꢀXQNVCIGꢀFTQRꢀHQTꢀUVCTVKPIꢀTQQOꢀCKTꢀEQPFKVKQPGTꢀKUꢀPQVꢀNGUUꢀVJCPꢀꢆꢂꢓꢀQHꢀVJGꢀTCVGFꢀXQNVCIGꢐꢀ#PFꢀVJGPꢃꢀCꢀXQNVCIGꢀOGVGTꢀYKNNꢀ
DGꢀWUGHWNꢀVQꢀEJGEMꢀVJGꢀTCVGꢀQHꢀVJGꢀXQNVCIGꢀFTQRꢐꢀ
10-7
Samsung Electronics
Download from Www.Somanuals.com. All Manuals Search And Download.
10-5 Flare Nut Fixing Torque
..
Torque((kkgg cm)
Outer diameter
Fixing Torque
Final Torque
ø 1/4 inch
(Liquid Side)
160
200
ø 3/8 inch
(Gas Side)
300
500
350
550
ø 1/2 inch
(Gas Side)
Samsung Electronics
10-8
Download from Www.Somanuals.com. All Manuals Search And Download.
10-6 "Pump down" Procedure
10-6-1 MH050FXCA2A
Pump down will be carried out when an evaporator is replaced or when the unit is relocated in another area.
1) Remove the caps from the 2 way valve and
the 3 way valve.
2 way Valve
2) Turn the 3 way valve clockwise to close and
connect a pressure gauge (low pressure side)
to the service valve, and open the 3 way valve
again.
3 way Valve
3) Set the unit to cool operation mode.
(Check if the compressor is operating.)
4) Turn the 2 way valve clockwise to close.
5) When the pressure gauge indicates "0" turn the
3 way valve clockwise to close.
6) Stop operation of the air conditioner.
7) Close the cap of each valve.
Relocation of the air conditioner
• Refer to this procedure when the unit is relocated.
• 1. Carry out the pump down procedure (refer to the details of ‘pump down’).
• 2. Remove the power cord.
• 3. Disconnect the assembly cable from the indoor and outdoor units.
• 4. Remove the flare nut connecting the indoor unit and the pipe.
• 4. At this time, cover the pipe of the indoor unit and the other pipe using a cap or vinyl plug to avoid foreign
material entering.
• 5. Disconnect the pipe connected to the outdoor unit.
• 4. At this time, cover the valve of the outdoor unit and the other pipe using a cap or vinyl plug to avoid foreign
material entering.
• 6. Make sure you do not bend the connection pipes in the middle and store together with the cables.
• 7. Move the indoor and outdoor units to a new location.
• 8. Remove the mounting plate for the indoor unit and move it to a new location.
10-9
Samsung Electronics
Download from Www.Somanuals.com. All Manuals Search And Download.
Reference for Installation
10-6-2 MH080FXCA4A
Pump down will be carried out when an evaporator is replaced or when the unit is relocated in another area.
1) Remove the caps from the 3/8" service valve and
the 5/8" service valve.
5/8" Service Valve
3/8" Service Valve
2) Turn the 5/8" service valve clockwise to close and
connect a pressure gauge (low pressure side)
to the service valve, and open the 5/8" service valve
again.
3) Set the unit to cool operation mode.
(Check if the compressor is operating.)
4) Turn the 3/8" service valve clockwise to close.
5) When the pressure gauge indicates "0" turn the
5/8" service valve clockwise to close.
6) Stop operation of the air conditioner.
7) Close the cap of each valve.
Relocation of the air conditioner
• Refer to this procedure when the unit is relocated.
• 1. Carry out the pump down procedure (refer to the details of ‘pump down’).
• 2. Remove the power cord.
• 3. Disconnect the assembly cable from the indoor and outdoor units.
• 4. Remove the flare nut connecting the indoor unit and the pipe.
• 4. At this time, cover the pipe of the indoor unit and the other pipe using a cap or vinyl plug to avoid foreign
material entering.
• 5. Disconnect the pipe connected to the outdoor unit.
• 4. At this time, cover the valve of the outdoor unit and the other pipe using a cap or vinyl plug to avoid foreign
material entering.
• 6. Make sure you do not bend the connection pipes in the middle and store together with the cables.
• 7. Move the indoor and outdoor units to a new location.
• 8. Remove the mounting plate for the indoor unit and move it to a new location.
Samsung Electronics
10-10
Download from Www.Somanuals.com. All Manuals Search And Download.
11. Reference Information
11-1 Index for Model Name
FREE JOINT MULTI FOR EUROPE
M
H
052
F
P
E
A
4
A
/
O
O
O
Buyer code
Product Type
Capa
Rating voltage
115V, 60Hz
Combination Quantity
M
Multi
*10Kw(3 digit)
A
B
C
D
E
M
_,12.. Indoor
FJM
220V, 60Hz
1,2.. Outdoor
208~230V, 60Hz
200~220V, 50Hz
220~240V, 50Hz
127V, 50Hz
Mode
C/O
Comp. Type
C
H
F
Free Inverter
Version
_,12.. Indoor
H/P
D
Redd Digital Scroll
_,A,B.. Outdoor
Indoor/Outdoor Type
Refrigerant
R22
K
1 way
Z
C
A
S
M
D
E
Slim 1 way
Mini 4 way
Silhouette
Slim
CST
Duct
R407C
R410A
P
G-P
W
V
HB
RAC
Vivave
R
N
X
Moderato
Console
Outdoor
CONV
11-1
Samsung Electronics
Download from Www.Somanuals.com. All Manuals Search And Download.
Index for Model Name (cont.)
FREE JOINT MULTI FOR EUROPE
M
H
V
V
1
X
-
07
/
O
O
O
1
8
Buyer code
Product Type
Capa
Serial Version
Basic
Indoor Capacity
- CAP Indoor(K BTU)
M
Multi
*K BTU
1
2
FJM
MR(02R~)
_
Outdoor
Mode
C/O
Refrigerant
R410A Inverter
R22
C
H
V
Z
Semi Product
Indoor
H/P
_
C
R407C
X
Outdoor
Indoor Type
G-P
P
W
V
HB
RAC
Vivave
Moderato
R
Samsung Electronics
11-2
Download from Www.Somanuals.com. All Manuals Search And Download.
11-2 Refrigerating Cycle Diagram
■ MH050FXCA2A
11-3
Samsung Electronics
Download from Www.Somanuals.com. All Manuals Search And Download.
Reference Information
■ MH080FXCA4A
Samsung Electronics
11-4
Download from Www.Somanuals.com. All Manuals Search And Download.
11-3 Pressure & Capacity mark
■ Power/Heat
.
.
W
cal/s
0.23885
kcal/h
0.85985
Btu/h
3.4121
HP
0.001341
0.0056146
0.0015596
3.9302x10-4
1
kg m/s
ib m/s
1
0.10197
0.73756
4.1868
1.163
1
3.6
14.286
3.9683
1
0.42693
0.11859
0.029885
76.04
3.088
0.85778
0.21616
550
0.27778
0.06999
178.11
2.3423
0.32383
1
0.29307
745.7
0.252
641.19
8.4322
1.1658
2,544.4
33.462
4.6262
9.8067
1.3558
0.013151
0.0018182
1
7.233
1
0.13826
11-4 The abbreviated technology words & the definition of technology terms
Abbreviated technology words
Definition of technology terms
One that compresses, especially a machine used to compress gases.
One that blows, especially a mechanical device, such as fan, that produces a current of air.
A device for reeating a current of air or a breeze.
COMP(Full name compressor)
BLOWER
FAN
A restraining device of air-condition, measure, or limit.
ASS’Y CONTROL BOX
(Full name : Assemble control box)
Something, such as a machine or an engine, that produces or imparts motion.
MOTOR
Heat exchanger; A device, used to transfer heat from a fluid on one side of a barrier to a fluid
on the other side without bringing the fluids into direct contact.
ASS’Y EVAP/ASS’Y COND
(Full name : assemble evaporator /
assemble condenser)
11-5
Samsung Electronics
Download from Www.Somanuals.com. All Manuals Search And Download.
11-5 Q & A for Non-trouble
Classification
Class
Q
Description
The cooling is weak.
A
When it is hot outside, its cooling capacity decreases due to the increase of the ambient temperature.
When the dust filter gets blocked or warm outside air gets in, the cooling capacity will decrease. So,
make sure to clean the dust filter frequently, prevent heat loss by closing the doors and insulate the
cooling area by using curtains, blinds, shades or window tinting.
Q
The cooling is good generally. But, it gets weak when it is considerably hot.
A
It occurs when the outdoor unit is exposed to direct sun light and heat-up air is not ventilated well.
So, set up a sunblind over the outdoor unit and keep stuff away from the unit to increase the ventila-
tion. When the cooling capacity decreases during a heat wave, clean the heat exchanger of the out-
door unit or spray some cold water to the heat exchanger to increase the cooling capability.
Cooling
Q
The cooling is weak. Does it need refrigerant charging?
A
It is not correct charging refrigerant regularly. Except that you have moved in several times or the
connection pipes are broken, the refrigerant does not run low. So, when refrigerant is additionally
charged, it could be costly and cause a product's failure. When the refrigerant leaks, all of it will
escape in a short time resulting in cooling failure and no water coming out of the drain hose. So, if
water comes out from the drain hose, it indicates the normal operation of the product and it does not
need refrigerant charging.
Q
It fails to do cooling.
A
When the air conditioner is set to Ventilation or the desired temperature is set higher than the current
temperature, it fails to do cooling. In this case, select Cooling or set the desired temperature lower.
Q
It floods the floor.
A
Place the drain hose properly. When it is not placed properly, the drain water would flow back flooding
the floor. So, straighten out the drain hose for the water to be drained well.
Q
Water drips at the drain connection (service valve) of the outdoor unit.
A
When a glass bottle is taken out of the refrigerator, moisture gets condensed on its surface due to the
temperature differences. The same principle applies to the air conditioner. When cold refrigerant goes
through the copper tube, moisture gets condensed on the surface of the tube and the connection
areas. To prevent the water condensation, the pipes are insulated. But, the connection areas of the
outdoor unit are not insulated for the purpose of maintenance or repair, and water gets condensed due
to the temperature differences and drips down. Generally, it evaporates right away. But, when it drips
much during muggy days, put a water pan on the floor.
Leakage
Q
It leaks even though a drain pump is used.
A
It occurs when the drain pump is plugged out or it is out of order. Check the power of the drain pump
and the position of the drain hose, and when the pump is faulty, contact the drain pump manufacturer.
Samsung Electronics do not manufacture drain pumps. So, we are not able to correct the drain pump
problems.
Q
Whenever the air conditioner is turned on, it irritates my eyes and gives me a headache.
A
There are no components in the air conditioner irritating the eyes and sending out chemical smells.
But, when the air conditioner is turned on, other smell sources are sucked into the air conditioner and
get out of it. So, find and root out the smell sources. Generally, it occurs at a interior renovated place,
a pharmacy, a gasoline handling place, a tire shop, a second-hand book shop or an electronic
Smells
Samsung Electronics
11-6
Download from Www.Somanuals.com. All Manuals Search And Download.
Q & A for Non-trouble (cont.)
Classification
Class
Description
component handling place; when its chemical or musty smells are sucked in and sent out, it can be
misled that the air conditioner generates them. So, find and root out the problem or refresh the room
frequently.
Q
Whenever the air conditioner is turned on, it stinks.
A
There are no components in the air conditioner sending out chemical smells. But, when the air condi-
tioner is turned on, other smell sources are sucked into the air conditioner and get out of it. So, find
and root out the smell sources. Generally, when the drain hose is taken out to the washing room or
there are sources of smells such as a diaper bin, a shoe shelf or a socks bin, bad smells generate.
Also, it occurs where glass cleaners or air fresheners are used; when they are sucked in interacting
with dusts and moistures inside, bad smells generate. These kinds of organic materials noxious to
human bodies. So, we recommend against the use of them.
Q
Whenever the air conditioner is turned on, it smells sour.
A
When the room is papered recently, its paste smells would be sucked inside. Also, when the air condi-
tioner is installed in the study room of young boys loving sweat-generating activities such as the bas-
ketball, excessive sweats evaporate and get sucked into the air conditioner resulting in bad smells. So,
find and root out the problem or refresh the room frequently.
Smells
Q
Whenever the air conditioner is turned on, it smells musty.
A
It is due to the improper keeping of the product after its use. When keeping the product, dry up the
inside with the operation of Ventilation to prevent must. When the product is kept without drying up the
inside with Ventilation, mold would grow inside resulting in must. So, open the windows and switch on
the Ventilation function to get rid of the saturated smell inside.
Q
Whenever the air conditioner is turned on, it sends out bad smells such as stale smells.
A
It occurs generally when there are pet animals in the house. Their smells stay at the same place.
But, when the air conditioner is turned on, the air gets circulated resulting in the circulation of the
smells. So, find and root out the problem or refresh the room frequently.
Q
It sends out bad smells.
A
When the air filter is filthy, it could send out bad smells. So, clean the filter and ventilate the room with
the windows open while operating the Ventilation function.
Q
A
Q
A
It won't start.
There is a power failure or it is plugged out. Also, check if the power distribution panel is switched off.
It goes off during operation.
When the hot air does not escape properly, it goes off during operation. It occurs when it does not
ventilate properly because the outdoor unit is covered, the back of the outdoor unit is blocked by a
cardboard or a plywood panel, and the front of the outdoor unit is blocked by the closed window or
other obstacles. Clear the above obstacles from the outdoor unit.
Operation
Q
It generally works properly. But, when it's considerably hot, it goes off during operation.
A
It occurs when the outdoor unit is exposed to direct sunlight and the hot air does not escape properly.
Set up a sun blind over the outdoor unit and clear the neighboring obstacles from the outdoor unit to
provide good ventilation. When it goes off frequently during a heat wave, it would prevent the turn-off and
increase the cooling capacity cleaning the outdoor unit or spraying some water to the heat exchanger.
11-7
Samsung Electronics
Download from Www.Somanuals.com. All Manuals Search And Download.
Q & A for Non-trouble (cont.)
Classification
Class
Q
Description
The remote controller won't operate.
A
When the batteries run out or the transmitter or receiver of the remote controller is blocked by obsta-
cles, change the batteries or keep the obstacles away from the controlling area. Also, the remote con-
troller may not work under intensive light from a 3-wave length lamp or a neon sign due to the EMI.
In this case, take the remote controller closer to the receiver.
Operation
Q
Who installs the air conditioner? (Relocation/Re-installation)
A
When relocating or re-installing the air conditioner, make sure to contact Samsung Electronics Service
Center or Authorized Service Agent and have them to do the job.(If not, it could cause personal injury
or product damage.)
The cost for the relocation/re-installation of the air conditioner is subject to the customer's expense.
There is a cost table. But, our service engineer needs to visit to total up the cost correctly.
When you move in, make sure to contact Samsung Electronics Service Center or Authorized Service
Agent in advance to streamline the process.
Q
Is it possible to install the outdoor unit outside?
A
It is possible to install it at a designated place in the apartment or on the rooftop nearby.
But, it's illegal hanging an angle iron case with the outdoor unit in it outside the apartment. Also, it is
illegal obstructing passers-by with the outdoor unit installed outside.
Installation
Q
What can be done to install the outdoor unit facing the road because it is a commercial building?
A
The following is an excerpt from Building Code going into effect from JUNE 1st 2005. "The exhaust
pipe of a cooling or ventilation facility installed in a building adjacent to the streets of commercial or
residential areas shall be installed higher than 2m to prevent the exhaust air from blowing directly to
passers-by and the current facilities shall be corrected by MAY 31st 2005." So, please install it higher
than 2m or not to blow the hot exhausting air directly to passers-by.
Q
What about installing a windscreen during installation not to blow hot air directly to passers-by?
A
When the hot air from the front of the outdoor unit is blocked, the product's performance will be
affected and it will fail to operate properly. So, keep it at least 300mm away from its surrounding walls
and give it good ventilation.
Samsung Electronics
11-8
Download from Www.Somanuals.com. All Manuals Search And Download.
11-6 Common sense of refrigeration
11-6-1 Air supplier
■ Air supplier?
It supplies fresh air to the building or room through procedure of air circulation for fresh environment.
■ Effectiveness of air supplier
It diminishes the stress or fatigue and enhances vivid desire through fresh air circulation. Also, filthy air indoor is being
cleaned by Air-Filter and it keeps clean and fresh environment and dehumidification. Temperature, humidity, air stream,
cleanness are called for factors of air supplier and they are kept in proper condition for usage purpose.
Humidity
(Moisture)
Control the indoor air into cool or warm
Remove humidity in air or humidify
Temperature
(Heat)
Air stream
(Aircirculation)
Cleanness
(Air)
Remove filthy dirt in air
Circulate air every corner of indoor
■ Four factors of air suppliers
The human body keeps regular temperature regarding the human body's freshness.
For keeping freshness, heat generated from human body should emit outside of the body by air circulation, conduction,
emission, and evaporation. The human body feels freshness when the emission rate is 40~45%, which was emitted by a
radiation when it is comfortable and warm, and air circulation and conduction is 20~30%, and evaporation is 20~24%.
It sometimes may depends on seasonal factor, wearing condition, age, sex and mental state other than indoor environment.
But generally the value of fresh indoor temperature is that below 0.2(m/s) of indoor air circulation, the temperature is 21~28˚C
when the wall temperature is the same as the indoor's and relative humidity is 30~31% in summer, the winter temperature is
20~24˚C and relative humidity is 30~60% in winter.
11-9
Samsung Electronics
Download from Www.Somanuals.com. All Manuals Search And Download.
ELECTRONICS
GSPN(Global Service Partner Network)
Area
Web Site
North America
Latin America
CIS
http://service.samsungportal.com
http://latin.samsungportal.com
http://cis.samsungportal.com
http://europe.samsungportal.com
http://china.samsungportal.com
http://asia.samsungportal.com
http://mea.samsungportal.com
Europe
China
Asia
Mideast & Africa
This Service Manual is a property of Samsung Electronics Co., Ltd.
Any unauthorized use of Manual can be punished under applicable
International and/or domestic law.
© Samsung Electronics Co., Ltd. Jan. 2008.
Printed in Korea.
Code No. DB98-29161A(3)
Download from Www.Somanuals.com. All Manuals Search And Download.
|