USER’S MANUAL
Cassette Type Series
1 Way cassette :
AVMKH(C)
/AVXC1
/ KH(C)
EAM/
FK
KH EAV/MH
Slim 1Way cassette :
AVXCS
/SH
EAV
2 Way cassette :
AVMGH(C)
/AVXC2
/GH(C)
EAM
/
4 Way cassette :
AVMCH(C)
/AVMC4
/ AVXC4
EAM / CH(C)
CH(C)
EZM /CH
EAV
mini 4 Way cassette :
AVXCM
/TH
EAV /MH
FM
System Air Conditioner
1
1
S
W
W
l
i
m
a
a
y
y
4
4
m
i
c
c
W
a
a
a
n
s
s
i
y
s
s
e
e
c
c
W
t
t
t
t
2
a
a
e
e
a
s
s
W
y
s
e
t
a
y
t
e
e
c
s
a
e
s
t
t
s
e
t
t
e
E S F
I
P D G R DB98-26442A(7)
Download from Www.Somanuals.com. All Manuals Search And Download.
Contents
PREPARING YOUR AIR CONDITIONER
Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
View of the Indoor unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3
8
RECOMMENDATIONS FOR USE
Periodical Checks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Protections enabled by the Unit control system. . . . . . . . . . . . . . . . . . . . . . .
9
9
Operating Recommendations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Temperature and Humidity Ranges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Cleaning Your Air Conditioner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Solving Common Problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Correct Disposal of This Product
(Waste Electrical & Electronic Equipment)
(Applicable in the European Union and other European countries with separate collection systems)
This marking shown on the product or its literature, indicates that it should not be disposed with other household wastes
at the end of its working life. To prevent possible harm to the environment or human health from uncontrolled waste
disposal, please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of
material resources.
Household users should contact either the retailer where they purchased this product, or their local government office,
for details of where and how they can take this item for environmentally safe recycling.
Business users should contact their supplier and check the terms and conditions of the purchase contract.
This product should not be mixed with other commercial wastes for disposal.
E-2
Download from Www.Somanuals.com. All Manuals Search And Download.
Safety Precautions
You should take the following safety precautions when using your air conditioner.
• Risk of electric shock can cause injury or death.
WARNING
•
Disconnect all remote electric power supplies before servicing, installing or cleaning.
• Installation must be done by the manufacturer or service agent or a similar
qualified person in order to avoid a hazard.
WHEN INSTALLING
Do not install the air
conditioner where there’s
combustible gas.
Do not install the outdoor
unit where there’s the risk of
dropping such as on high
outer wall or outside of the
terrace.
Earth the ground conductor
and do not connect it to the
gas pipe, water pipe or
telephone wire.
Contact the service center if the air conditioner
is under water.
REGARDING POWER SOURCE
Do not pull the electric wire or
touch the power plug with the
wet hands.
Install the switch and circuit
breaker only for
air conditioner.
Use the rated current fuse.
Do not bend the electric wire
by force or weigh down the air
conditioner not to be out of
order.
Use the power source with
separate wiring only for air
conditioner.
If the power plug is
damaged, replace it by the
manufacturer or qualified
personal to avoid the risk.
E-3
Download from Www.Somanuals.com. All Manuals Search And Download.
WARNING
DURING OPERATION
Users of this product are
Never spill any kind of liquid
into the unit. Should this
happen, unplug or main
switch off the unit and
contact an authorized
service center.
Do not insert anything
between the air outlet blades
because the inner fan may
be damaged and could cause
injury. Keep children away
from the unit.
cautioned not to attempt
repair of this product at their
own discretion. Instead, they
are requested to directly
contact a designated service
center or the outlet at which
the product was purchased.
Do not place any obstacles in
front of the unit.
Make sure that the unit is
correctly ventilated at all times.
Do not place clothing or other
materials over it.
If the wireless remote
control is not used for
a long time, remove the
batteries. (If applicable)
When using a wireless remote
control, the distance should
not be more than 7m(23ft)
from the air conditioner.
(If applicable)
Do not place any materials so
that children cannot step on it.
Do not connect the electric
heater to the air conditioner
or repair it with your
discretion.
E-4
Download from Www.Somanuals.com. All Manuals Search And Download.
WARNING
DISPOSING THE UNIT
Before throwing out the
device, it is necessary to pull
back the battery cells and get
rid of them safely for recycling
reasons.
When you need to dispose of
the unit, consult your dealer.
If pipes are removed
Please recycle or dispose
of the packaging material
for this product in an
environmentally responsible
manner.
incorrectly, refrigerant may
blow out and come into
contact with your skin, causing
injury. Releasing refrigerant
into the atmosphere also
damages the environments.
CAUTION
WHEN INSTALLING
Install the air conditioner
avoiding direct sunlight or
heater, especially water.
Install the outdoor unit so as
to let the discharged air out
properly. Avoid a place that
may disturb your neighbor by
noise.
Install the drain hose to let
the water run safely and
correctly.
E-5
Download from Www.Somanuals.com. All Manuals Search And Download.
CAUTION
REGARDING POWER SOURCE
Disconnect the circuit breaker
when you don’t use
the air conditioner for a long
time to save energy.
Contact the service center or
manufacturer if you want to
repair the air conditioner.
Contact the service center
after turning off the air
conditioner if strange noise
is heard, burning smell or
smoke blows.
DURING OPERATION
Do not open the front grille
during operation.
Avoid cold and hot air
reaching to person, pet or a
plant directly for a long time.
Avoid the water from
getting into the
air conditioner.
Do not use the air conditioner
for a long time in a closed
room or in a place where
Do not step on the air
conditioner or put heavy
object on it.
Do not drink the water from
the air conditioner.
there’s a baby or an old person.
E-6
Download from Www.Somanuals.com. All Manuals Search And Download.
CAUTION
DURING OPERATION
Do not touch the pipes
connected to the air
conditioner.
Do not use the air conditioner
to maintain the machine, food,
pet, plant or cosmetics.
Do not give excessive shock
to the air conditioner.
OTHERS
The appliance is not intended
for use by young children or
infirm persons without
supervision: Young children
should be supervised to
ensure that they do not play
with the appliance.
Max current is measured
according to IEC standard for
safety and current is
measured according to ISO
standard for energy efficiency.
Be sure that the air filter not to
be exposed to direct sunlight.
Turn off the air conditioner
and if the fan stops operating,
clean the air conditioner.
Do not clean the air
The surface of the heat
exchanger is sharp, so be
careful of it when cleaning.
conditioner by spraying water
directly or with benzene,
thinner or alcohol.
Clean the air filter every
2 weeks.
Be sure to insert the air filter.
E-7
Download from Www.Somanuals.com. All Manuals Search And Download.
View of the Indoor Unit
The figures are shown in this instruction may differ from yours depending on the model.
1 way & Slim 1 way cassette
2 way cassette
Indoor Unit
Air flow blade
Air inlet
Air flow blades(outlet)
Air inlet
Air filter(inside the grille)
Timer indicator
Fan indicator
Filter Sign indicator
Fan indicator
Remote control sensor
- Heat Pump Models :
On/Off indicator(Green)
& Removing frost
indicator(Red)
- Cooling Only Models :
On/Off indicator
Timer indicator
Filter sign indicator
On/Off indicator
On/Off button
Remote control sensor
4 way & mini 4 way cassette
Indoor Unit
Type A
Timer indicator
On/Off button
On/Off indicator
Fan indicator
Remote control sensor
Removing frost indicator
Filter Sign indicator
Type B
Air flow blades
(outlet)
Filter Sign indicator
Timer indicator
Fan indicator
Air inlet
Removing frost indicator
Remote control sensor
Air filter
(under the grille)
On/Off indicator
On/Off button
Type C
Filter Sign indicator
Timer indicator
Fan indicator
Removing frost indicator
Remote control sensor
On/Off indicator
On/Off button
E-8
Download from Www.Somanuals.com. All Manuals Search And Download.
Periodical Checks
Type
Description
Clean the air filter
Monthly
Every 4 months Once a year
(1)
Clean the condensate drain pan (2)
Thoroughly clean the heat exchanger (2)
Clean the condensate drain pipe (2)
Replace the remote control batteries
Indoor unit
Clean the heat exchanger on the outside
of the unit (2)
Clean the heat exchanger on the inside
of the unit (2)
Clean the electric components with jets
of air (2)
Outdoor unit
Verify that all the electric components
are firmly tightened (2)
Clean the fan (2)
Verify that all the fan assembly is firmly
tightened (2)
Clean the condensate drain pan (2)
The checks and maintenance operations described are essential to guarantee the efficiency of the air conditioner.
The frequency of these operations varies according to the characteristics of the area, the amount of dust, etc.
(1) The described operations should be performed more frequently if the area of installation is very dusty.
(2) These operations must always be performed by qualified personnel. For more detailed information, see the
Installation Manual.
Protections enabled by the Unit control system
Type of protection
Description
Operation
When it enables
Heating on
heat pump
Protection against cold air
The internal fan is off
During operation
Heating on
heat pump
Defrost cycle
The internal fan is off
The compressor is off
During operation
Anti-frost protection
of internal battery
Cooling During
operation
At start-up or during
the selection
of the operating mode
The start of the
compressor is delayed.
Cooling or Heating
on heat pump
Delayed start of compressor
CAUTION
If the air conditioner is operating in heat pump mode, it performs several defrost cycles in order
to remove the frost that may have deposited on the outdoor unit (at low temperatures).
In this case, the internal fan is switched off automatically and restarted only after the defrost
cycle is completed.
E-9
Download from Www.Somanuals.com. All Manuals Search And Download.
Operating Recommendations
Here are a few recommendations that you should follow when using your air
conditioner.
Topic
Recommendation
Heating performances
The heat pump function of the air conditioner
absorbs heat from outside air and brings it indoors.
As the temperature of the outside air drops,
the heating performance of air conditioner will decrease.
If you find that the room is not warm enough,
using an additional heating appliance is
recommended.
Frost & Defrost
When outside temperature is low but humidity is high,
frost may form on the outdoor unit at HEAT mode.
If this happens:
The heating operation stops.
T
he defrost mode will be triggered automatically for
about 10 minutes.
he steam produced on the outdoor unit in the defrost
mode is safe. (Only for Heat pump)
T
No intervention is required ; after about ten minutes,
the air conditioner operates again normally.
High indoor and outdoor If both indoor and outdoor temperatures are high
temperatures
and the air conditioner is running at HEAT mode,
the outdoor unit’s fan and compressor may stop
at times. This is normal ; simply wait until the air
conditioner switches on again.
Power failure
If a power failure occurs while the air conditioner is
operating, the unit will be switched off. When the power
returns, the air conditioner starts up again automatically.
The simultaneous
operation
When you use the heat pump model, it is impossible to
operate HEAT and COOL mode of several indoor units at
the same time.
E-10
Download from Www.Somanuals.com. All Manuals Search And Download.
Temperature and Humidity Ranges
The following table indicates the temperature and humidity ranges, within which the air conditioner can be used.
If the air conditioner is used at...
Then...
High temperature
The automatic protection feature may be triggered and
the air conditioner stopped.
Low temperature
A water leakage or some other malfunction may happen if the heat
exchanger freezes.
High humidity levels
Water may condense on and drip from the surface of the indoor unit if it is
used for a long period.
Outdoor
Mode
Indoor
Temperature
Indoor
Humidity
Remark
Temperature
-20°C/-4°F to 24°C/75°F
27°C/81°F or less
15°C/59°F to 27°C/81°F
27°C/81°F or less
DVM PLUS II, BAC Inverter(UH052/060/070EAV1)
BAC
-5°C/23°F to 24°C/75°F
Heating
-
-15°C/5°F to 24°C/75°F
Free Joint Multi, DVM, BAC Inverter(UH026/035EAV1)
BAC Inverter
-10°C/14°F to 24°C/75°F
-5°C/23°F to 43°C/109°F
27°C/81°F or less
18°C/64 to 32°C/90°F
DVM, DVM PLUS II, BAC Inverter
BAC, Free Joint Multi
-5°C/23°F to 43°C/109°F 21°C/70°F to 32°C/90°F
-10°C/14°F to 43°C/109°F 18°C/64 to 32°C/90°F
Cooling
Drying
80% or less
BAC Inverter(UH026/035EAV1)
BAC Inverter(UH052/060/070EAV1)
DVM, DVM PLUS II, Free Joint Multi, BAC Inverter
BAC
-15°C/5°F to 43°C/109°F
-5°C/23°F to 43°C/109°F
18°C/64 to 32°C/90°F
18°C/64 to 32°C/90°F
-5°C/23°F to 43°C/109°F 21°C/70°F to 32°C/90°F
-10°C/14°F to 43°C/109°F 18°C/64 to 32°C/90°F
-
BAC Inverter(UH026/035EAV1)
BAC Inverter(UH052/060/070EAV1)
-15°C/5°F to 43°C/109°F
18°C/64 to 32°C/90°F
The standardized temperature for heating is 7°C/45°F. If the outdoor temperature drops to 0°C/32°F or below,
the heating capacity can be reduced depending on the temperature condition.
If the cooling operation is used at over 32°C/90°F(indoor temperature), it does not cool at its full capacity.
1 Way cassette Slim 1 Way cassette 2 Way cassette
4 Way cassette mini 4 Way cassette
AVMCH(C)
AVMC4
DVM Model
AVMKH(C)
AVXC1
-
AVMGH(C)
AVXC2
-
DVM PLUS II Model
BAC Model
AVXCS
AVXC4
AVXCM
CH(C)EAM
CH(C)EZM
KH(C)EAM
KHEAV
-
GH(C)EAM
-
BAC Inverter Model
SHEAV
-
-
CHEAV
THEAV
Free Joint Multi Model MHFK
-
-
MHFM
E-11
Download from Www.Somanuals.com. All Manuals Search And Download.
Cleaning Your Air Conditioner
To get the best possible use out of your air conditioner, you must clean it
regularly to remove the dust that accumulates on the air filter.
CAUTION
Before cleaning your air conditioner, ensure that you have
switched off the electric circuit breaker used for the unit.
1 way cassette
1 way & Slim 1 way cassette
1
1 way cassette
Open the front grille by pushing the tabs on the grille.
Slim 1 way cassette
Open the front grille by pushing the [PUSH] tabs located in 3 places and pull
Slim 1 way cassette
out the air filter.
CAUTION
You must give attention when disassembling the front grille
and must check the safety clips have been installed.
If you do not check them, the front grille will drop suddenly
and you will be hurt.
2
Remove the front grille.
1 way cassette
2-1 Remove the safety clips.
2-2 Open the front grille about 45° and pull it forward.
3
4
Pull out the air filter.
Slim 1 way cassette
Remove all dust on air filter with a vacuum cleaner or a brush. In case of
serious dust accumulation, put the air filter in warm detergent water and
shake it vertically.
5
After washing, allow them to dry throughly in an area protected from sunlight.
When you have finished, insert the filter into the front grille.
Clean the unit with a vacuum cleaner or a brush once a month.
Reinstall the front grille and the safety clips.
6
7
8
T he design and shape are subject to
change according to the model.
Note
After cleaning the air conditioner, press the Filter Reset button.
Wired Remote Control
Wireless Remote Control(Type A)
Wireless Remote Control(Type B)
E-12
Download from Www.Somanuals.com. All Manuals Search And Download.
2 way cassette
1
Open the front grille by pushing on both sides and center.
CAUTION
You must give attention when disassembling the front grille
and must check the safety clips have been installed.
If you do not check them, the front grille will drop suddenly
and you will be hurt.
2
Remove the front grille.
2-1 Remove the safety clips.
2-2 Open the front grille about 45° and pull it forward.
3
4
Pull out the air filters.
Remove all dust on air filters with a vacuum cleaner or a brush. In case of
serious dust accumulation, put the air filter in warm detergent water and
shake it vertically.
Safety Clip
Note
When you have installed the Bio-Pure filter, do not allow any
liquid to contact the filter. It may lose its properties.
5
6
7
8
After washing, allow them to dry throughly in an area protected from sunlight.
When you have finished, insert the air filters into the front grille.
Clean the unit with a vacuum cleaner or a brush once a month.
Reinstall the front grille and the safety clips.
Note
You can use all 2 points of the indoor unit for installing the front
grille and the safety clips depending on your requirement.
Note
After cleaning the air conditioner, press the Filter Reset button.
Wired Remote Control
Wireless Remote Control(TypeA)
Wireless Remote Control(TypeB)
E-13
Download from Www.Somanuals.com. All Manuals Search And Download.
Cleaning Your Air Conditioner (Continued)
4 way & mini 4way cassette
1
Open the front grille by pushing on both sides and center.
CAUTION
You must give attention when disassembling the front grille
and must check the safety clips have been installed.
If you do not check them, the front grille will drop suddenly
and you will be hurt.
2
Remove the front grille.
2-1 Remove the safety clips.
2-2 Open the front grille about 45° and pull it forward.
3
4
Pull out the air filters.
Remove all dust on air filters with a vacuum cleaner or a brush. In case of
serious dust accumulation, put the air filter in warm detergent water and
shake it vertically.
Note
When you have installed the Bio-Pure filter, do not allow any
liquids to contact the filter. It may lose its properties.
5
6
7
8
After washing, allow them to dry throughly in an area protected from sunlight.
When you have finished, insert the air filters into the front grille.
Clean the unit with a vacuum cleaner or a brush once a month.
Reinstall the front grille and the safety clips.
Note
You can use all 2 points of the indoor unit for installing the front
grille and the safety clips depending on your requirement.
T he design and shape are subject to
change according to the model.
Note
After cleaning the air conditioner, press the Filter Reset button.
Wired Remote Control
Wireless Remote Control(TypeA)
Wireless Remote Control(TypeB)
E-14
Download from Www.Somanuals.com. All Manuals Search And Download.
Solving Common Problems
Before contacting the after-sales service, perform the following simple checks.
They may save you the time and expense of an unnecessary call.
Problem
Explanation/Solution
The air conditioner does not
operate at all.
Check if power is on and operate the air conditioner again.
Check if the circuit breaker is switched off.
Check if Off Timer is set.
The temperature is not adjusted.
Check if you selected the FAN mode.
The air conditioner does not operate
in the HEAT mode.
Check if the air conditioner is cooling only model.
Check if the remote control is for cooling only model.
The cool(warm) air does not come
out from the air conditioner.
Check if set temperature is higher(lower) than current temperature.
Check if you selected the FAN mode. Select the COOL, HEAT, AUTO or
DRY mode.
Check if the air filter is blocked by dirt. Clean the air filter regularly.
Check if the there is cover on the outdoor unit or any obstacle.
Remove the cover or obstacle.
Check if you installed the air conditioner under direct sunlight.
The window or door may be opened.
Check if you turn on the air conditioner just now.
It takes about 3 minutes to cool or heat the room.
Check if the refrigerant pipe is too long.
The fan speed is not adjusted.
In AUTO or DRY mode, the fan speed is selected automatically.
The remote controller does
not operate.
Check if the battery is discharged. Replace the battery.
Check if the remote controller sensor is blocked.
Check if the air conditioner is placed near strong light.
The wired remote controller
does not operate.
Check if
/
is displayed on the wired remote controler.
Turn off the air conditioner and switch off the circuit breaker.
Contact the service center.
The Timer is not set.
Check if you pressed the
button after selecting time.
The air conditioner does not turn on
or off with the wired remote controller.
Check if you set the wired remote controller for group control.
Odor is permeated in the
room during operation
Check if you use the air conditioner in smoky area or there is a smell.
Ventilate the room or select the FAN mode for 1~2 hours.
The indoor unit indicator
flashes.
Press the
button to turn on the air conditioner again.
Switch the circuit breaker off and switch on it again.
Strange sound is heard from
the air conditioner.
The sound is heard when the refrigerant gas flow is changed depending
on the use of the air conditioner.
When you press the
button, noise may be heard from the drain
pump inside of the air conditioner.
When you press the
button, noise may be heard that the
air conditioner sense the airflow blade.
Water drops from the outdoor
unit connection part.
Water may form due to the difference of the temperature.
E-15
Download from Www.Somanuals.com. All Manuals Search And Download.
|