Digital Access Keypad Manual
User Operation for the SK-1011-SQ
n
n
n
n
indicates
Note:
the inhibit code.
1. Using the User Codes:
A. User codes operate the door (4-8 digits long).
u
u
u
u
indicates
Note:
the user code.
u
u
u
u
Press
#
B. The
key must also be pressed if the keypad is in manual-entry mode.
X
X
X
X
Note:
indicates
u
u
u
u
Press
#
the master code.
2. Using the Master Code:
The Master Code can be used to operate the door or program the keypad
(4-8 digits long, see pt. 4 below).
A. To operate the relay output:
X
X
X
X
#
#
1
Press
B. Inhibit/lockout code:
X
X
X
X
2
Press
MANUAL
3. Using the Inhibit/Lockout Code:
A. Inhibit/lockout codes temporarily lock the keypad. (4-8 digits long, see pg. 5 for more information)
n
n
n
n
Press
#
B. The
key must be pressed also if the keypad is in manual-entry mode.
SK-1011-SQ
Digital Access Keypad
with 5A Relay Output
n
n
n
n
#
Press
4. User Code and Master Code Programming:
A. Enter the Master Code first, followed by the key
*
(If you forgot the master code, see page 7 for more information.)
X
X
X
X
Press
B. Change/Add/Delete User or Master Codes:
*
u
u
u
u
1
#
Press
C. Deleting Individual Users:
Press 00-99 (user ID)
D. Changing the Master Code:
00-99 (user ID)
(user code, 4-8 digits)
#
#
1
X
X
X
X
Press
0
E. To exit programming mode, press the key.
*
WARRANTY
This SECO-LARM product is warranted against defects in material and workmanship while used in normal
service for a period of one (1) year from the date of sale to the original consumer customer. SECO-LARM’s obligation is
limited to the repair or replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM.
This Warranty is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect,
repair, or alteration, improper or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines
that such equipment is not operating properly as a result of causes other than defects in material and workmanship.
The sole obligation of SECO-LARM, and the purchaser’s exclusive remedy, shall be limited to replacement or repair only,
at SECO-LARM’s option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or consequential
personal or property damages of any kind to the purchaser or anyone else.
NOTICE: The information and specifications printed in this manual are current at the time of publication. However, the
SECO-LARM policy is one of continual development and improvement. For this reason, SECO-LARM reserves the right
to change specifications without notice. SECO-LARM is also not responsible for misprints or typographical errors.
Copyright © 2008 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or copied, in
whole or in part, without the written permission of SECO-LARM.
SECO-LARM® U.S.A., Inc.
16842 Millikan Avenue, Irvine, CA 92606
Tel: 800-662-0800 / 949-261-2999 Fax: 949-261-7326
®
E-mail: sales seco-larm.com
PIHAK1
@
MT_08Keypad3i.pmd
SECO-LARM U.S.A., Inc.
Download from Www.Somanuals.com. All Manuals Search And Download.
Page 8
Digital Access Keypad Manual
Digital Access Keypad Manual
INSTALLER PROGRAMMING
SPECIFICATIONS:
Power:
These functions should only be used by professional installers, as incorrect entries can disable the entire keypad function.
Enter Programming Mode
0
0
0
0
(DEFAULT:
)
• Operation voltage -- 12-24 Volts AC/DC. No jumper needed to set voltage.
• Stand-by current drain -- 10mA @12VDC.
• Active current drain (press keypad key) -- Under 30mA.
• Active current drain (relay activated) -- Under 80mA.
Outputs:
Enter Master code
Confirm
Function
*
X
X
X
X
Enter into programming mode
*
*Key in the Master Code.
Note: For first-time use, Master code is
0
0
0
0
Data Refresh
Option
Confirm
Function
Clears all previously stored data.
• Relay output -- 5A @ 28VDC, Form "C", N.O./C./N.C., programmable for 1 to 999 second timed output or
shunt (start/stop) output. Three terminals.
8
9
0
1
#
• Tamper output -- N.C. output. Connect to tamper circuit of alarm control panel. Two terminals.
Inputs:
Configure Relay Outputs
Option Output time
(DEFAULT: Momentary, 1-sec. output)
Function
Confirm
• Power -- 12-24Volts AC/DC. Two terminals.
• Egress -- N.O., ground (-). Single terminal.
Code Operation:
4
0
1 to 999
Relay momentary mode, from 1 to 999 seconds
Relay shunt mode (ON/OFF)
#
#
4
1
Relay Output Inhibit Control (lockout mode)
(DEFAULT: Momentary, 1-sec. output)
• Up to 100 user codes, 10,000 possible user code combinations.
• Max. 10 seconds to enter each digit.
• Max. 30 seconds to enter each code.
Option Code Entry
Function
Confirm
5
0
1 to 999
Lockout for 1 to 999 seconds
Lockout shunt mode (ON/OFF)
#
#
5
1
Dimensions (keypad with back box):
• 4-5/8" x 2-7/8" x 1-7/8" (117 x 74 x 48 mm).
Weight (keypad with back box):
Wrong Code Lockout
Option
(DEFAULT: 10 tries / 30 seconds)
Function
# of tries Confirm
7
0
After 10 successive wrong codes, 30-second lockout
After 10 successive wrong codes, Duress activated
After 5 to 10 wrong codes, 15-min. lockout - Can reset with Master Code
None of the above
7
7
1
2
• 6.3 oz. (180 grams).
5 to 10
#
#
7
6
0
0
Output Activation Announcer
(DEFAULT: On)
WIRING (SAMPLE INSTALLATION):
Option Code entry
Confirm
Function
1
#
1-sec. beep notifies the user to open the door when the output relay is activated with the
user code or egress button. Use with a locking device which gives no sound when it
activates, such as a magnetic lock.
8
1
{
0
#
The beep is disabled, replaced by 2 short beeps for valid user codes.
(+) (--)
12~24VAC/DC
EG
Tamper
N.C.
OUTPUT 1
N.C. C. N.O.
User Code Entry Mode
Option Code entry
(DEFAULT: Manual)
Confirm
Function
1
#
#
Auto Entry Mode is selected. The key that follows the user code is NOT required in
Connect to the N.C.
24hr. zone of alarm
panel or other
(+)
code entry. The User Codes MUST be set to the same digit length as the Master Code,
8
2
from 4-8 digits.
{
0
#
#
Manual Entry Mode is selected. The key that follows the user code is required in
code entry. The User Codes can be 4-8 digits, but not necessarily all of the same length.
N.C. N.O.
OR
signalling device.
(DEFAULT: On)
Keypress Beeps
Option Code entry
Confirm
Function
--
+
1
#
Keypad beeps when a key is pressed.
8
3
Electric
Lock
{
0
#
Silent operation -- keypad does not beep when a key is pressed.
12VDC
power
supply
--
+
Exit Programming Mode
Confirm
Function
Exits programming mode, returns keypad to normal operations
*
REMARKS:
(for DC
use only)
Output relay
Diode
N.O. output for fail-secure lock.
N.C. output for fail-safe lock.
USER CODE WORKSHEET
1N4004
Cathode
To print out a blank worksheet where all user codes
and select the Model #, "SK-1011-SQ" in the drop
down menu for the burglar section. On the product
page click on "User Code Worksheet," which will
load the .PDF.
Additional egress buttons
Egress button (inside the
protected premises)
can be connected in parallel
as needed
N.O.
N.O.
SECO-LARM U.S.A., Inc.
Download from Www.Somanuals.com. All Manuals Search And Download.
Page 6
Page 3
Digital Access Keypad Manual
Digital Access Keypad Manual
USER PROGRAMMING
PREPARING TO PROGRAM THE KEYPAD
Enter Programming Mode
Enter Master code
Before programing the SK-1011-SQ, you will need to first determine the following information:
1. The master code -- Allows the system administrator to program or operate the keypad.
2. The user code or codes -- Allows users to use the keypad's functions.
Confirm
Function
X
X
X
X
Enter into programming mode
*
X
X
X
X
Note:
indicates the Master code.
Note: For first-time use, Master code is "0000".
3. The inhibit/lockout code -- When inputted, prevents the relay from operating even if a correct user code
is inputted.
Adding Or Changing Master And User Codes
User ID
Access code
4 to 8 digits
4 to 8 digits
Function
Option
0
Confirm
Master Code
4. Configuration of the relay output -- Determine whether the output should operate from 1 to 999 seconds
and then turn OFF (momentary mode), or turns ON/OFF via the code (shunt mode).
#
1
00 to 99
#
Add or change up to 100 User Codes
Note: No user code can be the same code as the master code or the inhibit/lockout code.
5. Result of improper code entry -- Choose between a 30-second code lockout, duress output, a 15-minute
code lockout, or no reaction.
Delete A User
To delete a user who has left the company or who no longer has authority to enter the protected area:
1. Enter Programming Mode:
GETTING STARTED
Enter Master code
Confirm
Function
EXIT THE
PROGRAMMING
MODE BY PRESSING
A master code is required to program the keypad. The default master code is set to "0000." To change the
master code, go to page 7 and follow the instructions for "MASTER CODE BYPASS (DAP jumper)."
X
X
X
X
Enter into programming mode
*
EXIT
2. Delete code
THE
KEY
Function
Confirm
Option
User ID
00 to 99
*
Once the master code is set, review the programming options and decide exactly what the keypad will do,
including the format of the user access codes as well as how the keypad responds via the relay output,
buzzer and LEDs. Note that in every case the basic steps for programming are:
1
#
Deletes specific user ID
Set Inhibit / Lockout Code (see page 2)
1. Enter the master code, followed by the key, which puts you in programming mode.
1. Enter Programming Mode:
*
Enter Master code
Confirm
Function
Enter into programming mode
#
Note: to set
lockout duration,
see page 6
2. Enter the programming codes defined in the various sections as needed, followed by the key.
X
X
X
X
*
3. Enter the
key again to exit the programming mode.
2. Set code
Option
*
Access code
4 to 8 digits
Confirm Function
Sets inhibit/lockout code
Note: A rapid string of 5 beeps and/or 5 LED flashes indicates an error, while 2 beeps indicates that the
entry has been accepted.
2
1
#
BUZZER AND LED SIGNALS
The keypad's built-in buzzer and the auxiliary red/green LED can signal the following:
PROGRAMMING NOTES
1. Master code: The SK-1011-SQ comes pre-programmed with the Master Code set at 0000. Additional
codes and/or data should be programmed at the owner's discretion. However, to ensure security,
program a new personal Master Code to replace the factory-set Master Code as soon as possible.
______________S_t_a_t_u_s___________________B__u_z_z_e_r__T_o_n__e_s_*__________A_m__b_e_r__L_E__D__F_l_a_s_h_e_s_____
1. In programming mode N/A ON
_____________________________________________________________________________________
2. Successful key entry
1 beep
1 flash
_____________________________________________________________________________________
2. Factory defaults:
3. Successful code entry
2 beeps
2 flashes
_____________________________________________________________________________________
Master code
0000
4. Unsuccessful code entry
5 beeps
5 flashes
_________________________________________________________________________
_____________________________________________________________________________________
User code length
4 to 8 digits
5. DAP jumper not replaced Continuous beeps Continuous flashes
_____________________________________________________________________________________
_________________________________________________________________________
Main relay output time 1 second
6. In standby mode
N/A
1 flash in 2-sec. intervals
_____________________________________________________________________________________
_________________________________________________________________________
7. Output relay activated
1-sec. long beep**
N/A
Wrong code lockout
10 tries / 30 second
_________________________________________________________________________
NOTE: * The buzzer can be disabled through programming option 83.
** The output relay activated beep can be disabled through programming option 82.
Output activation announcer ON
_________________________________________________________________________
User code entry mode
Manual
_________________________________________________________________________
Amber
Red
Keypress beep
ON
LED INDICATORS
Green
_______________________________________________________________________
Silent operation OFF
O
O
O
Red LED -- Indicates that the door lock output has been inhibited.
Amber LED -- Flashes to show the keypad status (see above).
Green LED -- Lights while any output is activated.
1
4
2
5
3
6
3. Code operation: User codes are each four to eight digits and are assigned to two-digit IDs. If all the
codes have the same number of digits, the keypad can be programmed for whether the key must be
#
7
8
0
9
#
used or not after entering the code (see programming, option 820 or 821, page 6).
*
ENFORCER
The administrator can easily delete the code of one user via the two-digit ID, if the user is no longer
authorized to enter a protected area, without the need to teach the new code to all the other users.
SECO-LARM U.S.A., Inc.