Russound Stereo Amplifier PR 4Zi User Guide

PR-4Zi  
4-Zone, 6-Source  
Audio/Video Preamplifier  
INSTRUCTION MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
Product Overview . . . . . . . . . . . . . . .4  
Wiring Instructions . . . . . . . . . . . . . . .4  
Audio/Video Sources . . . . . . . . . . . . .4  
Connecting Amplifiers . . . . . . . . . . .5-6  
Common and Zone Trigger Outputs . . .6  
Connecting Video Monitors . . . . . . . . .7  
Source Loop Outputs . . . . . . . . . . . . .7  
Creating Subzones . . . . . . . . . . . . . .8  
Page Trigger Output . . . . . . . . . . . . .9  
Mute Input . . . . . . . . . . . . . . . . . . . .9  
Control Functions . . . . . . . . . . . . . .10  
PR-4Zi Control Functions . . . . . . . . . .10  
Memory Procedure . . . . . . . . . . . . .11  
Preset Procedure . . . . . . . . . . . . . .11  
Party Mode . . . . . . . . . . . . . . . . . . .11  
Peripheral Devices . . . . . . . . . . . . .12  
PCK Keypads . . . . . . . . . . . . . . . . .12  
Infrared Devices . . . . . . . . . . . . . . .12  
PCK Keypad Control Functions . . . . .13  
Paging . . . . . . . . . . . . . . . . . . . . . .14  
SPG Paging Module . . . . . . . . . . . . .14  
PTM-1 Paging Module . . . . . . . . . . . .14  
IR Emitters . . . . . . . . . . . . . . . . . . .15  
PRC-1 Remote Control . . . . . . . . . . .16  
Using the PRC-1 with the PR-4Zi . . . .16  
Multiple Controllers . . . . . . . . . . . . .17  
Using the RS-232 Comm. Port . . . . .18  
RS-232 Commands . . . . . . . . . . . . .19  
Technical Specifications . . . . . . . . . .20  
Warranty & Repair . . . . . . . . . . . . . .21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3
Product Overview  
The PR-4Zi is a four-zone, six-source A/V pream-  
plifier that offers independent control of source,  
volume, and tone for each zone. In addition to  
standard preamplifier controls, the PR-4Zi allows  
zone settings to be stored and recalled. SYS-  
TEM ON and SYSTEM OFF functions provide sin-  
gle-button, system-wide on/off control. Two  
PARTY modes link all zones for synchronous  
operation. Interface connections are provided for  
cascading as many as four PR-4Zis. An RS-232  
port allows the PR-4Zi to be controlled by touch  
panels or other automation devices that have an  
RS-232 interface. Optional Russound PCK or  
PCK-IR Keypads provide easy remote operation  
of the PR-4Zi. The optional Russound PRC-1  
Learning Remote allows users to operate source  
equipment from remote locations. Optional  
Russound SPG and PTM-1 Paging Modules add  
whole-house paging capabilities.  
Wiring Instructions  
AUDIO/VIDEO SOURCES  
Make line level and composite video connections  
from source equipment to the PR-4Zi as shown  
in Figure 1. Use high quality cables that are as  
short as possible to keep signal integrity intact.  
Figure 1 – A/V source connections  
VCR (EXAMPLE OF SOURCE)  
IN OUT  
V
L
R
Download from Www.Somanuals.com. All Manuals Search And Download.  
4
Wiring Instructions  
CONNECTING AMPLIFIERS  
Connect the Zone Output of each PR-4Zi zone to  
one line input of a multichannel amp. Figure 2  
shows a connection to the Russound DPA-6.12  
Twelve Channel Audio Amplifier. (Figure 2 also  
shows a trigger connection, discussed on p. 6.)  
If using multiple two-channel amplifiers, such as  
the Russound DPA-1.2, connect as shown in  
Figure 3 (see p. 6). Use good quality audio  
cables that are as short as possible to keep sig-  
nal integrity intact.  
Figure 2 – Multichannel amplifier connections, with tirgger connection shown to one channel  
PR-4Zi  
WARNING : SHOCK HAZARD –  
DO NOT OPEN  
AVRISQUE DE CHOC  
DPA-6.12 NEWMARKETH USA  
DESI
MAIN BUS  
INPUT  
LINE INPUT  
LINE INPUT  
LINE INT  
LINE INT  
LINE INT  
LINE IT  
R
L
R
L
R
L
R
L
R
L
R
L
R
L
L
L
L
L
L
L
GAIN  
R
GAIN  
R
GAIN  
R
GAIN  
R
GAIN  
R
GAIN  
R
SPEAKERS A  
SPEAKERS A  
SPEAKERS A  
SPEAKERS A  
SPEAKERS A  
SPEAKERS A  
R
L
BUS  
LINE  
STEREO  
BUS  
LINE  
STEREO  
BUS  
LINE  
STEREO  
BUS  
LINE  
STEREO  
BUS  
LINE  
STEREO  
BUS  
LINE  
STEREO  
BRGD  
BRGD  
BRGD  
BRGD  
BRGD  
BRGD  
MAIN BUS  
OUTPUT  
*
*
*
*
*
*
MONO  
IN  
MONO  
IN  
MONO  
IN  
MONO  
IN  
MONO  
IN  
MONO  
IN  
+12V  
+12V  
+12V  
+12V  
+12V  
+12V  
TRIGGER  
TRIGGER  
TRIGGER  
TRIGGER  
TRIGGER  
TRIGGER  
~120VAC  
~60Hz  
12A  
OUT  
OUT  
OUT  
OUT  
OUT  
OUT  
100mA  
100mA  
100mA  
100mA  
100mA  
100mA  
3
3
3
3
3
3
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
MUTING  
MUTING  
MUTING  
MUTING  
MUTING  
MUTING  
DELAYTIME  
DELAYTIME  
DELAYTIME  
DELAYTIME  
DELAYTIME  
DELAYTIME  
SPEAKERS B  
SPEAKERS B  
SPEAKERS B  
SPEAKERS B  
Russound  
SPEAKERS B  
SPEAKERS B  
DPA-6.12  
MINIMUM LOMPEDANCE:  
8 OHM PER NNEL WHEN BOTH SPEAKER A AND B OUTPUTS ARE USED  
4 OHM PER NNEL WHEN SPEAKER ONLY A OR B OUTPUT IS USED  
Conforms to  
UL 6500  
THIS UNIT MUST BE  
EARTH GROUNDED  
Tested to Comply  
* FOR BRIDGED OPERATION SEE MANUAL  
CSA C22.2 No1-94  
019  
SERIAL #  
68835  
FOR HOME OR OFFICE USE  
MADE INTAIWAN  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5
Wiring Instructions  
Figure 3 – Two-channel amplifier connections  
PR-4Zi  
VIDEO  
IN  
VIDEO  
INPUT  
SENSING  
VIDEO  
INPUT  
SENSING  
AIN  
AIN  
LINE INPUT  
SENSING  
12V  
TRIG  
LINE INPUT  
SENSING  
12V  
TRIG  
LINE INPUT  
SENSING  
12V  
TRIG  
INPUT  
R
R
R
SENSING  
DELAY  
DELAY  
DELAY  
INPUT  
INPUT  
INPUT  
5
1
5
1
5
1
L
L
L
4
2
4
2
4
2
3
3
3
12VTRIG  
12VTRIG  
12VTRIG  
WARNING : SHOCK  
HAZARD – DO NOT OPEN  
WARNING : SHOCK  
HAZARD – DO NOT OPEN  
WARNING : SHOCK  
HAZARD – DO NOT OPEN  
OUT 100mA  
OUT 100mA  
OUT 100mA  
R
R
R
AVIS : RISQUE DE CHOC  
ELECTRIQUE – NES PAS  
OUVRIR.  
AVIS : RISQUE DE CHOC  
ELECTRIQUE – NES PAS  
OUVRIR.  
AVIS : RISQUE DE CHOC  
ELECTRIQUE – NES PAS  
OUVRIR.  
SPEAKER AOUT  
AMPLIFIED INPUT  
SPEAKER AOUT  
AMPLIFIED INPUT  
SPEAKER AOUT  
AMPLIFIED INPUT  
* FOR BRIDGED OPERATION  
SEE MANUAL  
* FOR BRIDGED OPERATION  
SEE MANUAL  
* FOR BRIDGED OPERATION  
SEE MANUAL  
SENSING  
SENSING  
SENSING  
AC  
120V  
60Hz  
2A~  
AC  
120V  
60Hz  
2A~  
AC  
120V  
60Hz  
2A~  
DEFAULT  
DEFAULT  
DEFAULT  
SPEAKER BOUT  
SPEAKER BOUT  
SPEAKER BOUT  
AMPLIFIED INPUT  
AMPLIFIED INPUT  
AMPLIFIED INPUT  
Figure 4 – Common and Zone trigger outputs  
COMMON AND ZONE TRIGGER OUTPUTS  
The PR-4Zi provides four Zone-Specific and one  
Common +12VDC trigger outputs (Figure 4). The  
Zone-Specific triggers are turned on when the  
corresponding zone is on. The Common trigger  
is turned on when any zone is on. All trigger out-  
puts are turned on during a page. Figure 2 (p. 5)  
shows a Zone trigger connection to the  
Russound DPA-6.12 amplifier.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6
Wiring Instructions  
CONNECTING VIDEO MONITORS  
Each PR-4Zi zone has a composite video output to allow viewing video from any of six A/V sources.  
Connect monitors as shown in Figure 5 using RG6U cable with RCA type connectors. If more than two  
monitors are being used in a zone, a composite video distribution amplifier is recommended. The PR-  
4Zi video outputs are buffered and are good for up to 100’ of RG6U.  
Figure 5 – Video Output connections  
Figure 6 – Source Loop outputs  
SOURCE LOOP OUTPUTS  
The PR-4Zi has six buffered, fixed-level  
audio/video outputs (Figure 6). When set  
to SOURCE LOOP OUT, these output sig-  
nals from the corresponding input source.  
This source loop configuration allows the  
PR-4Zi to pass source signals to another  
component, such as a home theater con-  
troller, or to another PR-4Zi for sharing  
sources in a multiple controller system.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7
Wiring Instructions  
FIXED ZONE LINE OUT: CREATING SUBZONES  
The PR-4Zi has six buffered, fixed-level audio/video outputs as shown previously in Figure 1 (p. 4).  
When set to FIXED ZONE LINE OUT (Figure 7), the last four outputs can be used to create subzones  
of each main zone. A subzone gets the same source selected for the main zone, and therefore needs  
only on/off and volume control.  
The lower portion of Figure 7 shows four amplified Russound A-KP2 keypads added to Zone 1. All  
subzones get the same Zone 1 source, but will have independent on/off and volume control via the A-  
KP keypad. Main zone control can be acheived by repeating IR commands in a sub-zone into the main  
zones keypad input. D1 will accept IR signal for zone control.  
Figure 7 – Creating subzones  
PR-4ZI REAR  
SIGNAL TO SUB-  
ZONE IR OUTPUT  
TO  
GND  
KEYPAD  
PR-4ZI REAR  
SPEAKERS  
A-H4D  
Connection Hub  
AUDIO IN  
1
2
3
4
L
R
EMITTERS  
AUDIO  
OUT  
L
R
+12V  
200mA  
POWER  
+24V  
4A  
STATUS  
A-KP2 AMPLIFIED KEYPADS  
A-H4D CONNECTING BLOCK  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8
Wiring Instructions  
PAGING TRIGGER OUTPUT  
MUTE INPUT  
The PR-4Zi is equipped with a +12V paging trig-  
ger output (Figure 8) that switches on during a  
page. This output can be used to trigger an  
external amplifier, muting device, or other  
peripheral associated with paging. (Paging  
peripherals are discussed on page 14.)  
The PR-4Zi system mutes when a +12VDC signal  
is applied to the mute input (Figure 8). This  
allows connection of external paging or muting  
devices.  
Figure 8 – Paging trigger output  
and mute input  
REAR  
DOOR  
FRONT  
DOOR  
DIM-1 DOORBELL  
INTERFACE MODULE  
DOORBELL INTERFACE  
POWER  
+12V DC  
16VAC  
TRANSFORMER  
TRIG  
DOORBELL  
SLEEVE (–)  
TIP (+)  
12VDC POWER SUPPLY  
PART# 1201A  
REAR OF  
PR-4Zi  
Download from Www.Somanuals.com. All Manuals Search And Download.  
9
Control Functions  
Figure 9 – PR-4Zi control functions  
4
Z
O
N
E
6
S
O
U
R
C
E
A
U
D
I
O
/
V
I
D
E
O
P
R
E
A
M
P
L
I
F
I
E
R
SOURCE  
9
8
1
2
3
4
5
6
16  
1
1
3
2
4
1
2
3
4
13  
SYSTEM  
ON  
VOLUME  
POWER  
SOURCE LINK  
SOURCE /VOL LINK  
SYSTEM  
OFF  
ON/OFF  
BASS  
TREBLE  
2
LOUDNESS  
PARTY  
MEMORY  
PRESET  
ZONE SELECT  
10  
PR-4Zi  
3
4
5
6
7
11 12 14 15  
POWER – Controls power to entire system.  
IR Receiver – Provides IR control for Zone 1.  
ZONE SELECT – Selects current zone (1-4).  
ZONE SELECT Indicators – Shows current zone.  
1
2
3
4
5
SYSTEM ON & SYSTEM OFF – Turns all zones on or off. SYSTEM ON can be pre-  
set to selectively omit zone(s).  
ON/OFF – On/off control for current zone.  
6
7
ON/OFF Indicators – On/off status of current zone.  
Source Select – Changes source for current zone.  
Source Indicators – Shows selected source for current zone.  
8
9
BASS & TREBLE Controls – Adjusts BASS and TREBLE (/) for  
10  
current zone. Bass & treble: 12 steps each, 2dB per step (-12dB to +12dB).  
11  
LOUDNESS – Selects LOUDNESS on/off for current zone. Loudness  
selectively boosts bass & treble output at low volumes.  
12  
13  
14  
15  
16  
PARTY – Selects from 2 PARTY modes (SOURCE LINK or SOURCE/VOL LINK).  
PARTY Indicators – Shows PARTY mode used.  
MEMORY – Initiates MEMORY mode for current zone.  
PRESET – Recalls stored settings for current zone.  
VOLUME – Controls VOLUME for current zone. Volume: 40 steps,  
2dB per step (-80dB to 0dB).  
Download from Www.Somanuals.com. All Manuals Search And Download.  
10  
Control Functions  
Refer to Figure 9 at left for the following procedures.  
MEMORY PROCEDURE  
1. Select a zone using ZONE SELECT.  
MEMORY allows for permanent storage of zone  
settings. Source, volume level, bass level, treble  
level, loudness, paging volume, and "SYSTEM  
ON disable" settings can be stored. Once  
stored, these settings can be accessed by  
pressing PRESET.  
2. Press PRESET.  
Pressing PRESET on a PCK keypad or PRC-1  
remote control will recall the settings for that  
local zone.  
PARTY MODE  
Two PARTY modes allow synchronous operation  
of all zones.  
To set MEMORY for a single zone:  
1. Select a zone using the ZONE SELECT.  
2. Adjust zone as desired.  
Source Link mode. Activated upon pressing  
PARTY once. Source settings are linked for all  
zones. Any changes to source selection at the  
PR-4Zi front panel will be made simultaneously in  
all zones. However, zone volumes can be adjust-  
ed independently.  
3. Press MEMORY. The MEMORY indicator will  
light.  
4. To store VOLUME, BASS, and TREBLE levels,  
press the (up) button for the correspon-  
ding function.  
Source Link mode procedure:  
5. To store current input source, press any source  
button.  
1. Set Zone 1 volume and source as desired for  
the entire system. Turn on each zone you  
want to include for PARTY mode.  
2. Press PARTY once. The SOURCE LINK indica-  
tor will light and the settings made for Zone 1  
will be reflected in all other zones currently  
turned on.  
6. To store loudness setting, press LOUDNESS.  
7. To prevent the zone from turning on when All  
On is activated, press SYSTEM ON.  
8. To preset paging volume, press VOLUME ▲  
(down)  
9. To exit, press MEMORY again. The MEMORY  
indicator should no longer be illuminated.  
Source/Volume Link mode. Activated upon  
pressing PARTY twice. Source and volume set-  
tings are linked for all zones. Any changes to  
source selection or volume in one zone will be  
made simultaneously in all others.  
To clear MEMORY for a single zone:  
1. Select a zone using ZONE SELECT.  
2. Press MEMORY followed by PRESET.  
3. Press MEMORY again to exit.  
Source/Volume Link mode procedure:  
1. Repeat Step 1 above.  
2. Press PARTY twice. The SOURCE/VOL LINK  
indicator will light and the settings made for  
Zone 1 will be reflected in all other zones cur-  
rently turned on.  
To clear MEMORY for all zones:  
1. Press MEMORY followed by SYSTEM OFF.  
PRESET PROCEDURE  
PRESET recalls settings for the current zone pre-  
viously stored in memory. A preset can be  
recalled at the PR-4Zi front panel, on a PCK(IR)  
keypad, or via the PRC-1 remote control.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
11  
Peripheral Devices  
PCK(IR) KEYPADS  
IR DEVICES  
Each of the PR-4Zi’s zones can be remotely  
operated by a keypad or IR device. There are  
four keypad ports on the rear panel. Each port  
accommodates as many as four Russound  
PCK(IR) keypads (4 per zone). Wire the PCK(IR)  
keypads to the PR-4Zi keypad input as shown  
below in Figure 10 using 22-24 AWG shielded 2  
twisted pair wire.  
The keypad ports are also compatible with  
infrared devices such as Russound 858, 1257,  
1258, and 844 IR receivers.  
Wire IR devices as shown in Figure 11 using 22-  
24 AWG 1 pair twisted wire with shield.  
Figure 11 – IR device wiring  
PR-4Zi BACK  
Figure 10 – PCK(IR) wiring  
PR-4Zi BACK  
CONNECT SHIELD  
TO GROUND  
4 CONDUCTOR  
2 TWISTED PAIR WIRE  
WITH SHEILD  
1 PAIR TWISTED WIRE  
WITH SHIELD  
D2  
D1  
GND  
V+  
858 IR  
RECEIVER  
ST  
IR GND V+  
PCK(IR) KEYPAD  
Download from Www.Somanuals.com. All Manuals Search And Download.  
12  
Peripheral Devices  
PCK(IR) KEYPAD CONTROL FUNCTIONS  
LOUD – Selects and indicates loudness on/off.  
Source Select – Selects and shows input source.  
Infrared Receiver – Receives IR commands  
from Russound PRC-1 remote or a source  
component’s remote. (PCK IR only)  
1
2
3
6
7
8
SELECT – Selects function (bass, treble,  
volume) to be adjusted with /buttons.  
SYSTEM ON – Turns all zones on.  
NOTE: The system on button will also  
flash to confirm IR reception.  
9
BASS / TREBLE / VOLUME Indicators –  
Shows function selected for adjustment.  
SYSTEM OFF – Turns all zones off.  
10  
/Buttons – Adjusts bass, treble, and  
volume.  
4 ZONE ON/OFF – Turns zone on/off.  
5
PRESET – Recalls stored zone settings.  
Figure 12 – PCK(IR) zone control functions  
9
BASS  
TREBLE  
SELECT  
VOLUME  
8
7
10  
TUNER  
CD  
TAPE  
VID1  
VID2  
DVD  
4
5
ZONE  
LOUD  
PRESET  
6
2
ON/OFF  
SYSTEM  
ON  
SYSTEM  
OFF  
3
PR-4Z SYSTEM CONTROLLER  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
13  
Peripheral Devices  
DSC/DAN KEYPADS  
OPERATING THE DSC/DAN KEYPADS  
Once the PCK(IR) keypads have been wired, con-  
nect the DSC keypad’s 16-pin header to the 16-  
pin receptacle on the side of the main keypad  
(see Figure 1a and 1b). Be sure to keep the cor-  
rect pin alignment. If you are using a DAN key-  
pad with the system, connect it to the input  
receptacle on the side of the DSC keypad.  
Select the source that you wish to control  
on the main keypad (this will also select the  
source for listening).  
1
2
3
Press the command key(s) on the DSC or  
DAN which have been programmed with the  
commands that you wish to execute.  
The Program indicator will flash as the  
command is outputted. If the Program  
indicator does not flash when the  
command key is pressed, the  
command was not stored properly.  
Figure 13 – DSC and DAN docking  
PCK-IR OR PCK  
DSC  
DAN  
BASS  
TREBLE  
SELECT  
VOLUME  
SEEK  
MODE  
2
5
8
0
1
4
3
6
SELECT  
SCAN  
TUNER  
CD  
TAPE  
7
9
VID1  
VID2  
DVD  
ZONE  
ENTER  
LOUD  
PRESET  
ON/OFF  
SYSTEM  
ON  
SYSTEM  
OFF  
DIRECT ACCESS  
NUMERIC SOURCE KEYPAD  
DIRECT SOURCE CONTROL  
PR-4Z SYSTEM CONTROLLER  
Download from Www.Somanuals.com. All Manuals Search And Download.  
14  
Peripheral Devices  
IKP-1 INFRARED KEYPAD PROGRAMMER  
The IKP-1 is a programmer used to simplify and  
speed up the IR programming for the DAN and  
DSC IR learning keypads. Learning keypads that  
can be used with the programmer have a plug  
located at the front left. Refer to IKP-1  
Instruction Manual for complete instructions.  
Figure 14 – Multiple Progamming with IKP-1  
DSC OR DAN  
KEYPAD  
IKP-1  
TO  
KEYPAD  
NEWMARKET, NH U.S.A.  
ERROR  
DAN  
DSC  
DATA  
TRANSFER  
DOWNLOAD  
UPLOAD  
TO KEYPAD  
FROM KEYPAD  
IKP-1  
INFRARED LEARNING  
KEYPAD PROGRAMMER  
POWER  
12VDC 100mA  
12VDC Power Supply  
Download from Www.Somanuals.com. All Manuals Search And Download.  
15  
Peripheral Devices  
PAGING  
SPG PAGING MODULE  
The PR-4Zi has five paging inputs. The four  
Zone-Specific PAGE INPUTS allow for paging to  
all zones except the zone where the page origi-  
nates. The PAGE ALL input will allow paging to  
all zones. A page turns on all zones to their  
respective preset paging volume (see Memory  
Procedure, p. 11). All devices triggered by any  
of the trigger outputs will also be turned on.  
Russound offers many paging options to suit  
most applications. See the Tech and FAQ sec-  
additional information.  
The Russound SPG provides "push-to-talk" opera-  
tion. Use 22-24 AWG twisted pair shielded wire  
to connect the SPG to the PR-4Zi page input as  
shown in Figure 15.  
PTM-1 PAGING MODULE  
The Russound PTM-1 is a signal-sensing paging  
adapter for the PR-4Zi that accepts the page  
output or other line-level audio output from tele-  
phone paging systems, paging preamplifiers,  
switch-triggered voice/sound recording devices,  
etc. Use 22-24 AWG twisted pair shielded wire  
to connect the PTM-1 to the PR-4Zi page input  
as shown in Figure 16.  
Figure 16 – PTM-1 wiring configuration  
PAGE  
OUT  
PTM-1 PAGETRIGGER MODULE  
IN  
T
S
G V  
Figure 15 – SPG wiring instructions  
ON TGR  
OUT  
SPG PAGING KEYPAD  
4 CONDUCTOR  
TGR  
SIG  
TWISTED  
TGR  
SIG  
GND  
12+  
PAIR SHEILD  
CP 4.6 PAGE INPUT  
GND  
12+  
SENSITIVITY  
ADJUSTMENT  
PR-4Zi PAGE INPUT  
TGR  
GND  
SIG  
T
G
MORE  
LESS  
S
12+  
+V  
Download from Www.Somanuals.com. All Manuals Search And Download.  
16  
Peripheral Devices  
Figure 17 – Source-specific infrared outputs  
IR EMITTERS  
The PR-4Zi has seven IR outputs:  
Source 1–6 and Common. Source  
1–6 outputs are source-specific and  
provide IR signals only to the  
selected source; the Common out-  
put provides IR signals to all  
sources.  
Source-specific IR outputs (Figure  
17) are useful when a system has  
two or more of the same model  
source component, allowing you to  
target the IR commands to each  
individual component.  
845.1 MICRO EMITTERS TO  
IR RECEIVER WINDOW  
OF SOURCE EQUIPMENT  
SOURCE 2  
SOURCE 1  
To connect multiple emitters to the  
Common IR output, use the  
Russound 857 connecting block  
and a 1/8-inch (3.5mm), 2-conduc-  
tor (mono) phone plug as shown in  
Figure 18. Connect common (COM)  
IR output to “IR INPUT” on the 857  
connecting block.  
Figure 18 – Common infrared output  
RUSSOUND #857  
CONNECTING BLOCK  
TIP  
SLEEVE  
L O C B K  
O C N N E C T I N G  
N I F R A R 8 E 5 D 7  
O N F I R I R M C  
1/8" (MONO)  
PHONE PLUG  
M E I T T E R S  
1
2
3
4
5
6
RUSSOUND #845.1 MICRO EMITTERS  
TO IR CONTROLLED EQUIPMENT  
STRIPE WIRE  
IS SIGNAL  
(WIRES TO TIP)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
17  
Peripheral Devices  
Figure 19 – PRC-1 Preprogrammed  
& Learning Remote Control  
PRC -1 REMOTE CONTROL  
The Russound PRC-1 remote control is prepro-  
grammed to operate more than 1,000 audio and  
video components, including the PR-4Zi. Set it up by  
simply punching in a three-digit code that matches  
your equipment. The PRC-1 also has the ability to  
learn new functions, allowing you to customize it and  
update it as you add new equipment. The PRC-1  
operates up to eight different audio and video com-  
ponents in a home entertainment system.  
AUD  
SAT  
CD  
TV  
DVD  
VCR  
AUX  
CBL  
The PRC-1 controls only the local zone you are in.  
POWER  
MUTE  
VOL  
CH  
USING THE PRC -1 WITH THE PR-4Zi  
T/V  
To activate the PRC-1 for use with the PR-4Zi:  
GUIDE  
MENU  
1. Turn on the PR-4Zi using its front-panel switch.  
PAUSE  
2. On the PRC-1, press the AUX and MUTE buttons  
simultaneously, then release.  
R
E
F
SEL  
PLAY  
W
F
3. Point the PRC-1 toward the PR-4Zi and press the  
three-digit code 0-8-1.  
4. On the PRC-1, press the AUX button again to  
store the code.  
5. Henceforth, pressing the AUX button on the PRC-  
1 accesses all the preprogrammed codes for the  
PR-4Zi.  
STOP  
PRE.  
CH  
EXIT  
1
2
3
FAV  
TUNER  
CD  
TAPE  
SLEEP  
4
5
6
INFO  
PRO.L  
VID 1  
VID 2  
DVD  
7
8
9
NEXT  
3.CH  
ALL ON  
ALL OFF  
PRESET  
+10  
PIP  
0
ENTER  
SHIFT  
ALT  
All the functions available on the PCK keypad are  
also available on the PRC-1. NOTE: The PRC-1 can  
turn on the local zone by pressing the POWER but-  
ton, and turn off that zone by pressing the MUTE  
button.  
TEST  
Ld  
TUNER  
SURR  
REAR CENTER DELAY  
BASS TREBLE  
TAPE  
M1  
CENTER  
M4  
M2  
M3  
SYSTEM  
ON  
SYSTEM  
OFF  
LIGHT  
PRC-1  
PROGRAMMABLE REMOTE CONTROL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
18  
Multiple Controllers  
INSTALLING MULTIPLE PR-4Zi CONTROLLERS  
As many as four PR-4Zis can be cascaded via  
DB-25 connectors. Cascading links multizone  
functions such as SYSTEM ON, SYSTEM OFF,  
PAGING, and PARTY mode so that these func-  
tions can be used system-wide. (In order to  
share sources among linked PR-4Zis you must  
connect the Source Loop outputs of the parent  
controller to the A/V inputs of controller #2, and  
so on.)  
The DB-25 cable needs to be a straight pass-  
through or RS232C rated with a male connector  
at both ends.  
ie. Radio Shack Part # 26-233  
Figure 20 – Interface cable connections for multiple PR-4Zi’s  
DB-25 MALE / MALE CONNECTOR  
Download from Www.Somanuals.com. All Manuals Search And Download.  
19  
Using the RS-232 Communications Port  
The PR-4Zi is equipped with one DB-9 connector for RS-232 communication with AMX™, Crestron™,  
and similar automation systems. All PR-4Zi control functions (except for paging) can be accessed  
through the RS-232 port. The PR-4Zi will also send confirmation data to the controlling system. These  
updates will be performed when any change has been executed or when the “SEND ZONE STATUS  
INFORMATION” request is sent to the PR-4Zi.  
CONTROLLER ADDRESS SWITCH SETTINGS  
Figure 21 –_Controller Address Switch  
Up to 16 zones can be controlled from a single RS-232  
port by setting the Controller Address Switch located left  
of the DB-9 connector (Figure 21).  
Controller #1 (Zones 1-4)  
Controller #2 (Zones 5-8)  
Controller #3 (Zones 9-12)  
Controller #4 (Zones 13-16)  
RS-232 COMMAND PROTOCOLS  
Commands are sent from RS-232 controlling device to the PR-4Zi as 8 ASCII bytes. The first two  
ASCII bytes “RU” establish that the command is a Russound command for zone commands only. The  
next 3 bytes “Z01” establish the zone to be controlled. The last 3 bytes “ZON” comprise the com-  
mand sent to that zone. Commands are sent as ASCII values, asynchronous, 4800 bps, 8 data bits, 1  
start bit, 1 stop bit, no parity.  
PR-4Zi FEEDBACK BYTES TO CONTROLLING DEVICE  
Feedback bytes will be sent immediately after a command is given to the PR-4Zi. The first decimal  
byte “101” (Zone 1) establishes which zone the update is for. The second decimal byte “40” (min. vol-  
ume has been set) is the update data. Each update starts with the zone number update value (101 -  
116) and is followed by a control update value (see list on next page). Commands are sent as deci-  
mal values, asynchronous, 4800 bps, 8 data bits, 1 start bit, 1 stop bit, no parity.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
20  
RS-232 Commands & Update Values  
MULTI-ZONE COMMANDS  
RUALZOZN system on  
RUALZOZF system off  
RUSORCLC party mode (source link)  
RUSORCLN party mode (source/volume link)  
ZONE COMMANDS  
Zone number (XX) can be between 01 and 16. Use the addressing switch  
(Figure 19) to set zone numbers (01-04), (05-08), (09-12), (13-16)  
RUZXXZON  
RUZXXZOF  
RUZXXVLU  
RUZXXVLD  
RUZXXBSU  
RUZXXBSD  
RUZXXTBU  
RUZXXTBD  
RUZXXSR1  
zone on  
zone off  
volume up  
volume down  
bass up  
bass down  
treble up  
RUZXXSR2 source input 2  
RUZXXSR3 source input 3  
RUZXXSR4 source input 4  
RUZXXSR5 source input 5  
RUZXXSR6 source input 6  
RUZXXPST preset  
RUZXXBSF bass level flat  
RUZXXTBF treble level flat  
RUZXXLOD loudness toggle on/off  
treble down  
source input 1  
RUZXXVLP volume level set followed by decimal value 40 (min) <-> 0 (max)  
RUZXXBSP bass level set followed by decimal value 0 (min) <-> 12 (max)  
RUZXXTBP trebel level set followed by decimal value 0 (min) <-> 12 (max)  
RUZXXSRD send zone status information  
ZONE NUMBER UPDATE VALUES  
UPDATE VALUES  
0 thru 40 update volume position 40 (min) <-> 0 (min)  
101 update to be sent for zone 1  
102 update to be sent for zone 2  
103 update to be sent for zone 3  
104 update to be sent for zone 4  
105 update to be sent for zone 5  
106 update to be sent for zone 6  
107 update to be sent for zone 7  
108 update to be sent for zone 8  
109 update to be sent for zone 9  
110 update to be sent for zone 10  
111 update to be sent for zone 11  
112 update to be sent for zone 12  
113 update to be sent for zone 13  
114 update to be sent for zone 14  
115 update to be sent for zone 15  
116 update to be sent for zone 16  
41  
42  
43  
44  
45  
46  
source 1 selected  
source 2 selected  
source 3 selected  
source 4 selected  
source 5 selected  
source 6 selected  
50 thru 62 update treble position 0 (min) <-> 12 (max)  
70 thru 82 update bass position 0 (min) <-> 12 (max)  
90  
91  
92  
93  
94  
95  
96  
zone is on  
zone is off  
loudness contour is on  
loudness contour is off  
source lock party mode selected  
source link party mode selected  
party mode is off  
200 update to be sent to all zones  
ALL OTHER UPDATE VALUES (0 <-> 255) OTHER THAN  
SHOWN ABOVE ARE RESERVED FOR FUTURE USE.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
21  
Technical Specifications  
Frequency Response: 20 - 20kHz + 0.1 dB max.  
Total Harmonic Distortion: 0.06% max.  
Signal-to-Noise Ratio: 95 dB min, "A" weighted  
Maximum input voltage: 4.6 VRMS, 6 Volts peak  
Maximum output voltage: 8.5 VRMS, 12 Volts peak  
Volume Control: 0 dB to -80 dB (40 steps)  
Bass and Treble Controls: +/- 12 dB (12 steps)  
Standard Features: 6 Audio / Video source inputs  
4 stereo audio/video outputs  
4 keypad / Infrared ports  
4 Paging unit ports  
5 +12V Trigger outputs (4 zone specific, 1 common)  
5 Infrared transport outputs (6 source specific, 1 common)  
Built-in IR receiver for zone #1  
RS-232 Interface for control of up to 4 PR-4Zi from an  
external control system  
Unit Interface allows cascading of up to four PR-4Zi (16 zones)  
Optional Features: Full function PCK keypad  
Full function PCK-IR keypad w/ built-in IR receiver  
DSC direct source control IR learning keypad  
DAN direct access numeric IR learning keypad  
In-wall SPG paging module  
PTM-1 telephone paging interface module  
PRC-1 programmable remote control  
Power requirements: AC 110 – 240 volts, 50 - 60Hz, 1 AMP.  
Dimensions: 19" W x 12" D x 3.6" H.  
Weight: 12 lbs.  
The PR-4Zi complies with the requirements of the standards for Audio Video Products and  
Accessories (UL 1492, 1st Edition) and Radio, Television, and Electronic Apparatus (CSA C22.2 No.  
1-M94).  
Download from Www.Somanuals.com. All Manuals Search And Download.  
22  
Warranty & Repair  
The Russound PR-4Zi is fully guaranteed against all defects in materials and  
workmanship for two (2) years from the date of purchase. During this peri-  
od, Russound will replace any defective parts and correct any defect in  
workmanship without charge for either parts or labor. For this warranty to  
apply, the unit must be installed and used according to its written instruc-  
tions. If service is necessary, it must be performed by Russound. The unit  
must be returned to Russound at the owner’s expense and with prior written  
permission. Accidental damage and shipping damage are not considered  
defects under the terms of the warranty. Russound assumes no responsibili-  
ty for defects resulting from abuse or servicing performed by an agency or  
person not specifically authorized in writing by Russound. Damage to or  
destruction of components due to improper use voids the warranty. In these  
cases, the repair will be made at the owner’s expense. To return for repairs,  
the unit must be shipped to Russound at the owner’s expense, along with a  
note explaining the nature of the service required. Be sure to pack the unit  
in a corrugated container with at least 3 inches of resilient material to pro-  
tect the unit from damage in transit.  
Before returning a unit for repair, call Russound at (603) 659-5170 for a  
Return Authorization number. Write this number on the shipping label and  
ship to:  
Russound  
5 Forbes Road  
Newmarket, NH 03857  
Attn: Service  
Download from Www.Somanuals.com. All Manuals Search And Download.  
23  
Russound  
5 Forbes Road, Newmarket, NH 03857  
tel 603.659.5170 • fax 603.659.5388  
fax-on-demand: 603.659.5590  
28-0105  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Radica Games Video Games 9834 User Guide
Radio Shack Door 63 1123 User Guide
Razor Mobility Scooter 13111290 User Guide
Reebok Fitness Treadmill RBTL118040 User Guide
Roland DJ Equipment SP 404SX User Guide
Samson Home Theater Server S Class User Guide
Samsung Car Stereo System GX SM530CF User Guide
Sanyo Vacuum Cleaner SC B550R User Guide
Sceptre Technologies Flat Panel Television SCEPTRE X405 HDTV User Guide
Sennheiser Headphones HD 520 II User Guide