DPA-6.12
Instruction Manual
12 Channel Amplifier
6
Z
O
N
E
—
1
2
C
H
A
N
N
E
L
A
M
P
L
I
F
I
E
R
1
2
3
4
5
6
POWER
ZONE
DPA-6.12
Download from Www.Somanuals.com. All Manuals Search And Download.
2. INTRODUCTION
Congratulations on your recent purchase of the Russound DPA-6.12 12-channel amplifier. The DPA-6.12 high-
current, high-quality amplifier is the heart of the home theater or multi-zone system. The DPA-6.12 12-channel
amplifier is capable of amplifying six stereo line level sources (CD players, tape decks, preamplifiers, tuners, etc.)
simultaneously in multi-zone, multi-source installations. The twelve amplifiers are arranged in pairs to provide six
stereo amplifiers. With separate gain controls for each channel, sound levels can be preset to accommodate most
rooms. The Main Bus Input allows for two or more stereo amplifiers to share the same audio source. With the
stereo/mono selector in the mono position, two amplifiers can serve as mono outputs. In the mono position the
six stereo pairs can be bridged to three stereo pairs for higher output power. The DPA-6.12 power output is 50
watts per channel into 8 ohms, and 75 watts into 4-ohms. Bridged adjacent outputs provide 100 watts of power
into 8-ohms and 150 watts of power into 4-ohms. All this power is backed by two high output toroidal transform-
ers. Each amplifier output channel incorporates thermal, short circuit protection and Russound’s unique Dynamic
Clipping Sensor that allows for better headroom and volume without clipping or distortion that is normally heard
in most amplifiers.
The Russound DPA-6.12 amplifier is built with pride. Fidelity, reliability and quality are the primary objective.
Russound products are guaranteed to provide years of enjoyment.
3. POSSIBLE SYSTEM CONFIGURATIONS
The DPA-6.12 can be configured as an audio distribution system, or used as the main amplifier for a home the-
ater system. As an audio distribution amplifier each zone can independently drive several different sources by
using each of the individual line audio inputs for each of the zones. As a home theater amplifier the DPA-6.12
output can be bridged to provide high power out for the front channel while the remaining channels are used to
drive the surround effects.
Conforms to
UL 1492
Certified to
CSA C22.2 #1
WARNING : SHOCK HAZARD – DO NOT OPEN
AVIS : RISQUE DE CHOC ELECTRIQUE – NES PAS OUVRIR.
PR-4Z
NEWMARKET, NH U.S.A.
AC TOAP-48
68835
UNIT INTERFACE A
INPUTS
OUTPUT TO ZONES
VIDEO
LEFT
UNIT INTERFACE B
SWITCHED
CMN
1
2
3
4
INPUTS
CD
AC OUTLETS
115V~ 60Hz
1A MAX TOTAL
IR
FUSE
10A
OUT
AC 115V~
60Hz 10A MAX
L
8A MAX
+
V
+
+
V
+
V
+
V
+
V
+
V
+
V
G
D1 D2
V
G
D1 D2
G
D1 D2
G
D1 D2
G
S
T
G
S
T
G
S
T
G
S
T
SERIAL #
R
RIGHT
TUNER
TAPE
VID1 VID2 DVD
1
2
3
4
KEYPAD 1
KEYPAD 2
KEYPAD 3
KEYPAD 4
PAGE 1
PAGE 2
PAGE 3
PAGE 4
WARNING : SHOCK HAZRD –
DO NOT OPEN
AS : RISQUE DE CHOC
ELCTRIQUE – NES PAS OUVRI
DPA-6.12 NEWMARKET, NH USA
DESIGNED IN
MAIN BUS
INPUT
LINE INPUT
LINE INPUT
LINE INPUT
LINE PUT
LINE UT
LINE IUT
R
L
R
L
R
L
R
L
R
L
R
L
R
L
L
L
L
L
L
L
GAIN
R
GAIN
R
GAIN
R
GAIN
R
GAIN
R
GAIN
R
SPEAKERS A
SPEAKERS A
SPEAKERS A
SPEAKERS A
SPEAKERS A
SPEAKERS A
R
L
LINE
BUS
STEREO
LINE
BUS
STEREO
LINE
BUS
STEREO
LINE
BUS
STEREO
LINE
BUS
STEREO
LINE
BUS
STEREO
BRGD
BRGD
BRGD
BRGD
BRGD
BRGD
MAIN BUS
OUTPUT
*
*
*
*
*
*
MONO
IN
MONO
IN
MONO
IN
MONO
IN
MONO
IN
MONO
IN
+12V
+12V
+12V
+12V
+12V
+12V
TRIGGER
TRIGGER
TRIGGER
TRIGGER
TRIGGER
TRIGGER
~120VAC
~60Hz
12A
OUT
OUT
OUT
OUT
OUT
OUT
100mA
100mA
100mA
100mA
100mA
100mA
3
3
3
3
3
3
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
∞
DELAYTIME
∞
DELAYTIME
∞
DELAYTIME
∞
DELAYTIME
∞
DELAYTIME
∞
DELAYTIME
MUTING
MUTING
MUTING
MUTING
MUTING
MUTING
SPEAKERS B
SPEAKERS B
SPEAKERS B
SPEAKERS B
Russound
SPEAKERS B
SPEAKERS B
DPA-6.12
MINIMUM LOAD IMPEDANCE:
8 OHM PER CHANNEL WHEN BOTH SPEAKER A AND B OUTPUTS ARE USED
4 OHM PER CHANNEL WHEN SPEAKER ONLY A OR B OUTPUT IS USED
Conforms to
UL 6500
Certified to
THIS UNIT MUST BE
EARTH GROUNDED
Tested to Comply
with FCC Standards
* FOR BRIDGED OPERATION SEE MANUAL
CSA C22.2 No1-94
019
SERIAL #
68835
FOR HOME OR OFFICE USE
MADE INTAIWAN
ZONE 3
ZONE 2
ZONE 1
ZONE 4
3
Download from Www.Somanuals.com. All Manuals Search And Download.
4. FRONT PANEL
Rack Mounting: The DPA-6.12 amplifier can be rack mounted. The amplifier will take four rack spaces.
Power Switch: Turns on the main power for the amplifier. When the power is on the LED will be illuminated.
Zone Indicator LEDs: Zone one to six will be illuminated when the zone is in the active mode. When the zone is
mute or inactive the LED will not be illuminated.
6
Z
O
N
E
—
1
2
C
H
A
N
N
E
L
A
M
P
L
I
F
I
E
R
1
2
3
4
5
6
POWER
ZONE
DPA-6.12
MAIN BUS
INPUT
R
L
R
L
5. BACK PANEL CONNECTIONS
Main Bus Input / Output: This is used when the input audio signal will be used
by more than one zone. The output is to loop out to another DPA-6.12 or other
amplifiers.
MAIN BUS
OUTPUT
LINE INPUT
Line Input: The line audio input at each zone is the left and right dedicated input for that zone.
R
L
This is a sensing input that will activate the zone when an audio signal is present. When there is
no audio the zone will go into standby.
LINE
Bus / Line Switch: Selects the Line audio input or the Main bus input for each
zone. When the Bus is selected the zone will amplify the audio on the Main
Bus input. When line is selected the zone will amplify the audio at the line
input for that zone.
BUS
Gain Controls: Left and Right gain controls adjust independently the sound level for each channel.
When used in the bridge mode only the right control is used.
L
GAIN
Stereo / Mono Switch: This selects stereo or mono for the speaker outputs. In
the Mono position each Left and Right output is Mono. The Mono selection will
R
STEREO
also be used to select operation for bridge mode. When Mono is selected the
inputs are summed and when in stereo the inputs remain independent to pro-
vide a stereo output.
BRGD
*
MONO
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Speaker Outputs: The A and B speaker outputs are in parallel to the amplifier output. When connected to the A or
B output either 4-ohm or 8-ohm speakers could be connected. When using both A and B speaker outputs, only 8-
ohm speakers can be connected, and this will result in a 4-ohm load at the amplifier. For Bridge amplifier opera-
tion, connect the + of the speaker to the R+ of the amplifier and - of the speaker to the L+ of the amplifer.
LEFT CHANNEL
LINE INPUT
RIGHT CHANNEL
LINE INPUT
LINE INPUT
LINE INPUT
R
L
R
L
LEFT CHANNEL
VOLUME CONTROL
RIGHT CHANNEL
VOLUME CONTROL
L
L
GAIN
R
GAIN
R
SPEAKERS A
SPEAKERS A
SET THIS SWITCH
TO BRGD MONO
FOR BRIDGING
SET THIS SWITCH
TO BRGD MONO
STEREO
STEREO
LINE
BUS
LINE
BUS
FOR BRIDGING
BRGD
BRGD
*
*
MONO
IN
MONO
IN
+12V
+12V
TRIGGER
TRIGGER
OUT
OUT
100mA
100mA
3
3
2
1
4
2
1
4
∞
∞
MUTING
MUTING
DELAYTIME
DELAYTIME
SPEAKERS B
SPEAKERS B
LEFT SPEAKER
EIGHT OHM
RIGHT SPEAKER
EIGHT OHM
IN
12 Volt Trigger In and Out: The Trigger output is 12 volts at a maximum of 150ma.
This can be used to drive a relay-operated AC outlet or other 12 volt triggered
devices. The 12-volt trigger input is used to activate a zone independent from the
auto turn on sensing circuit. The delay and audio sensing are bypassed when the
12 volt trigger input is used.
+12V
TRIGGER
OUT
100mA
3
2
1
4
Muting Delay Time: Muting delay can be adjusted from about 2 minutes to 10 minutes. When an
audio signal is not present, this delay setting will automatically put the amplifiers into standby
mode after the preset period of time.
∞
DELAYTIME
MUTING
~120VAC
Power: Two heavy-duty 500va toroidal transformers power the DPA-6.12. Each
~60Hz
12A
transformer has three taps to power 3 stereo zones, totaling six taps for the six
stereo outputs. The voltage setting for the AC input is set at the factory for opera-
tion of either 110 VAC 60Hz or 240 VAC 50Hz. Please reference the voltage rating
on the back panel. Includes detachable 3 terminal power cord.
THIS UNIT MUST BE
EARTH GROUNDED
5
Download from Www.Somanuals.com. All Manuals Search And Download.
6. SPECIFICATIONS
Audio power output: Continuous 50W @ 8 ohms, 75W @ 4 ohms.
Frequency response: 20HZ to 20KHZ -0.3dB.
Total harmonic distortion: 0.05% 8 Ohm, .075% 4 Ohm
Input sensitivity: 400mV line
Input impedance: 22k Line Input
Signal to noise ratio: 85dB
Input trigger: 12VDC 10k
Output trigger: 12VDC 150mA
Auto off delay time: 2 to 10 minutes
Primary fuse: T4A/250V 115VAC, T2A/250V 240VAC
Secondary fuse: T6.3A/250V
Power requirements: Factory set for 110 VAC 60Hz or 240 VAC 50Hz. IEC 320 type connector with
3 terminal detachable power cord. For 240VAC operation, use a power cord
(not supplied) rated for 240VAC 6.3 amps or higher.
Weight: 46 lbs.
Dimensions: 19" W x 17"D x 7.5"H
7. WARRANTY
The Russound DPA-6.12 is fully guaranteed for two (2) years from the date of purchase against all defects in
materials and workmanship. During this period Russound will replace any defective parts and correct any defect
in workmanship without charge for either parts or labor. For this warranty to apply, the unit must be installed and
used according to its written instructions. If service is necessary, it must be performed by Russound. The unit must
be returned to Russound at the owners expense and with prior written permission. Accidental damage and ship-
ping damage are not considered defects under the terms of the warranty. Russound assumes no responsibility for
defects resulting from abuse or servicing performed by an agency or person not specifically authorized in writing
by Russound. Damage to or destruction of components due to improper use voids the warranty. In these cases
the repair will be made at the owners expense. To return for repairs, the unit must be shipped to Russound at the
owners expense, along with a note explaining the nature of the service required. Be sure to pack in a corrugated
container with at least 3 inches of resilient material to protect the unit from damage in transit.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
5 Forbes Rd. Newmarket, NH 03857, USA
ꢀꢀ603.659.5170 • Fax 603.659.5388
e-mail: [email protected]