OWNER’S OPERATING MANUAL
TM
PL-50XA
Flat Panel Plasma Display Monitor
with
and
TM
Digital High Definition Controller
TM
with Vivix II Technology
Software Version 2.00
Download from Www.Somanuals.com. All Manuals Search And Download.
THREE YEAR LIMITED WARRANTY
For Plasma Displays
Congratulations on your purchase of a Runco video product and welcome to the Runco family! We believe Runco produces
“The World’s Finest Home Theater Products.” With proper installation, setup and care, you should enjoy many years of
unparalleled video performance.
This is a LIMITED WARRANTY as defined in the Magnuson-Moss Warranty Act. Please read it carefully and retain it with your
other important documents.
WHAT IS COVERED UNDER THE TERMS OF THIS LIMITED WARRANTY:
SERVICE LABOR: Runco will pay for service labor by a Runco Authorized Service Center when needed as a result of a
manufacturing defect for a period of three (3) years from the effective date of delivery to the end user (excluding the plasma
glass panel).
PARTS (not including plasma glass panel): Runco will provide new or rebuilt replacement parts for the parts that fail due to
defects in materials or workmanship for a period of three (3) years from the effective date of delivery to the end user. Such
replacement parts are then subsequently warranted for the remaining portion (if any) of the original warranty period.
PLASMA GLASS PANEL: Runco will pay for service labor by a Runco Authorized Service Center when needed as a result of a
manufacturing defect for a period of one (1) year from the effective date of delivery to the end user. In addition, Runco will
provide new or rebuilt replacement parts for the parts that fail due to defects in materials or workmanship for a period of one (1)
year from the effective date of delivery to the end user. Such replacement parts are then subsequently warranted for the
remaining portion (if any) of the original warranty period.
WHAT IS NOT COVERED UNDER THE TERMS OF THIS LIMITED WARRANTY:
Image burn-in on plasma display panels is specifically excluded from coverage under this Limited Warranty. Image burn-in is
the result of misuse of the product and therefore cannot be repaired under the terms of this Limited Warranty.
Normal viewing material such as television/satellite broadcasts, videotape or DVDs (not put into pause for extended periods of
time) will not cause damage to your display under normal conditions. Many DVD players are also equipped with screen savers
for this reason.
TO AVOID IMAGE RETENTION (Burn-in): Please ensure that still images are left on your plasma display panel for no more
than a few minutes. Also ensure that images displayed in the 4:3 aspect ratio mode (black or gray stripes, but no picture
information is present on the left and right edges of the screen) are used as infrequently as possible. This will prevent
permanent image burns on your plasma display panel, which can be seen permanently under certain conditions once burn-in
has occurred.
The types of images to avoid include video games, still images and computer screens with stationary tool bars and icons. (This
is why computers are equipped with screen savers – to prevent still images from burning into the monitor’s phosphors after
being displayed continuously for an extended period of time).
This Limited Warranty only covers failure due to defects in materials and workmanship that occur during normal use and does
not cover normal maintenance. This Limited Warranty does not cover cabinets or any appearance items; failure resulting from
accident, misuse, abuse, neglect, mishandling, misapplication, faulty or improper installation or setup adjustments; improper
maintenance, alteration, improper use of any input signal; damage due to lightning or power line surges, spikes and
brownouts; damage that occurs during shipping or transit; or damage that is attributed to acts of God. In the case of remote
control units, damage resulting from leaking, old, damaged or improper batteries is also excluded from coverage under this
Limited Warranty.
Runco PlasmaWall Owner’s Operating Manual
iii
Download from Www.Somanuals.com. All Manuals Search And Download.
CAUTION: THIS LIMITED WARRANTY ONLY COVERS RUNCO PRODUCTS PURCHASED FROM RUNCO AUTHORIZED
DEALERS. ALL OTHER PRODUCTS ARE SPECIFICALLY EXCLUDED FROM COVERAGE UNDER THIS LIMITED
WARRANTY. MOREOVER, DAMAGE RESULTING DIRECTLY OR INDIRECTLY FROM IMPROPER INSTALLATION OR SETUP
IS SPECIFICALLY EXCLUDED FROM COVERAGE UNDER THIS LIMITED WARRANTY.
RIGHTS, LIMITS AND EXCLUSIONS:
Runco limits its obligations under any implied warranties under state laws to a period not to exceed the warranty period. There
are no express warranties. Runco also excludes any obligation on its part for incidental or consequential damages related to
the failure of this product to function properly. Some states do not allow limitations on how long an implied warranty lasts, and
some states do not allow the exclusion or limitation of incidental or consequential damages. So the above limitations or
exclusions may not apply to you. This warranty gives you specific legal rights, and you may also have other rights that vary from
state to state.
EFFECTIVE WARRANTY DATE:
This warranty begins on the effective date of delivery to the end user. For your convenience, keep the original bill of sale as
evidence of the purchase date.
IMPORTANT – WARRANTY REGISTRATION:
Please fill out and mail your warranty registration card. It is imperative that Runco knows how to reach you promptly if we
should discover a safety problem or product update for which you must be notified.
CONTACT A RUNCO AUTHORIZED SERVICE CENTER TO OBTAIN SERVICE:
Repairs made under the terms of this Limited Warranty covering your Runco video product will be performed at the location of
the product, during usual working hours, providing location of product is within normal operating distance from a Runco
Authorized Service Center. In some instances it may be necessary for the product to be returned to the Runco factory for
repairs. If, solely in Runco’s judgment, location of product to be repaired is beyond normal operating distance of the closest
Runco Authorized Service Center, or the repair requires the unit be returned to the Runco factory, it is the owner’s
responsibility to arrange for shipment of the product for repair. These arrangements must be made through the selling Runco
Dealer. If this is not possible, contact Runco directly for a Return Authorization number and shipping instructions. Runco will
return product transportation prepaid in the United States, unless no product defect is discovered. In that instance, shipping
costs will be the responsibility of the owner.
COPYRIGHT AND TRADEMARKS:
© Copyright 2006 Runco International. This document contains proprietary information protected by copyright, trademark and
other intellectual property laws. All rights are reserved. No part of this manual may be reproduced by any mechanical,
electronic or other means, in any form, without prior written permission of the manufacturer.
Reflection, Enhanced GEN3, DHD, Vivix, Virtual Cinema, CineWide, AutoScope, O-Path, CinOptx, LiveLink, CSMS, SuperOnyx
and VirtualWide are trademarks of Runco International. All other trademarks and registered trademarks used in this document
are the property of their respective owners.
Runco International products are manufactured under one or more of the following patents: US. Patent 6755540 and Other
Patents Pending.
iv
Runco PlasmaWall Owner’s Operating Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
ADDITIONAL INFORMATION:
To locate the name and address of the nearest Runco Authorized Service Center, or for additional information about this
Limited Warranty, please call or write:
RUNCO INTERNATIONAL, INC.
Attn: Customer Service Department
2900 Faber Street
Union City, CA 94587
Ph: (510) 324-7777
Fax: (510) 324-9300
Toll Free: (800) 23-RUNCO
RUNCO VIDEO-PRODUCT INFORMATION
RETAIN THIS INFORMATION FOR YOUR RECORDS
_________________________________________________________
Model Purchased
________________________________________
Date
____________________________________________________________________________________________________________
Serial Number
____________________________________________________________________________________________________________
Runco Authorized Dealer Name
____________________________________________________________________________________________________________
Address
____________________________________________
__________________
State/Province
________________________
Postal Code
City
____________________________________________
Phone
_________________________________________________________
Fax
Runco PlasmaWall Owner’s Operating Manual
v
Download from Www.Somanuals.com. All Manuals Search And Download.
Safety Precautions
Thank you for your purchase of this quality Runco product! It has been designed to provide you with the quality of video that is
expected in a home theater. This manual is your guide through the menus and operation. For the best performance, please
read it carefully and keep it handy for future reference.
WARNING
This symbol is intended to alert the user to the presence of uninsulated
“dangerous voltage” within the product’s enclosure that may be of sufficient
magnitude to constitute a risk of electric shock.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION:
TO REDUCE THE RISK OF ELECTRIC SHOCK
DO NOT REMOVE COVER (OR BACK)
NO USER SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED
SERVICE PERSONNEL.
This symbol is intended to alert the user to the presence of important
operating and maintenance (servicing) instructions in the literature
accompanying the appliance.
CAUTION
To turn off main power, be sure to remove the plugs from power outlets. The power outlet socket should be installed as near to
the equipment as possible, and should be easily accessible.
WARNING
TO PREVENT FIRE OR SHOCK HAZARDS, DO NOT EXPOSE THIS UNIT TO RAIN OR MOISTURE. ALSO DO NOT USE THIS
UNIT’S POLARIZED PLUG WITH AN EXTENSION CORD RECEPTACLE OR OTHER OUTLETS, UNLESS THE PRONGS CAN
BE FULLY INSERTED. REFRAIN FROM OPENING THE CABINET AS THERE ARE HIGH-VOLTAGE COMPONENTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
WARNING
This equipment has been tested and found to comply with the limits for a Class ‘B’ digital device, pursuant to Part 15 of FCC
Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated
in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and
used in accordance with the Installation Manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area may cause harmful interference, in which case the user will be required to correct the
interference at his own expense.
DOC Compliance Notice
This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
Please read and follow the safety precautions listed below to ensure the equipment is free from damage, and to ensure that no
injury will occur as a result of improper use.
• Do not insert any object, especially metal or liquids, into the plasma display.
• Do not place any objects containing water or any other liquid on top of the plasma display.
• Do not place the units in direct sunlight, near heaters or in extremely dusty or humid locations.
• Do not install this system outdoors or otherwise exposed to the elements.
• Do not place heavy objects on top of the plasma display.
• If the power cord is damaged or frayed in any way, electrical shock and/or fire may result. Do not place objects on the
power cord, and keep the cord away from heat-emitting devices. Should the power cord become damaged in any way,
please contact your Runco Dealer for a replacement cord.
• Do not remove the cover of the plasma display for any reason. If any problems arise with the unit, please contact a Runco
Dealer or Runco International for service. Removing the covers will void the warranty.
vi
Runco PlasmaWall Owner’s Operating Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
1Table of Contents
THREE YEAR LIMITED WARRANTY .............................................................................iii
Safety Precautions .........................................................................................................vi
1. Introduction ...............................................................................................................1
About This Manual .......................................................................................................1
If You Have Comments About This Manual.............................................................1
Parts List ...............................................................................................................4
2. Controls and Functions ............................................................................................5
DHD Controller Front Panel ..........................................................................................8
DHD Controller Remote Control .................................................................................12
3. Installation ...............................................................................................................15
Notes on Batteries................................................................................................15
Notes on Remote Control Operation.....................................................................15
Quick Setup ...............................................................................................................17
Ventilation.............................................................................................................19
Other Considerations............................................................................................19
Runco PlasmaWall Owner’s Operating Manual
vii
Download from Www.Somanuals.com. All Manuals Search And Download.
RS-232 Controller Connection..............................................................................26
4. Operation .................................................................................................................29
Selecting the Input Source .........................................................................................30
Using the On-Screen Menus ......................................................................................32
5. Maintenance and Troubleshooting ........................................................................47
6. Serial Communications ..........................................................................................49
RS-232 Connection and Port Configuration ...............................................................49
7. Specifications ..........................................................................................................55
DHD Controller Specifications ....................................................................................56
PlasmaWall Dimensions .............................................................................................57
Computer/Video Signal Compatibility .........................................................................58
viii
Runco PlasmaWall Owner’s Operating Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
1List of Figures
2-4. DHD Controller Rear Panel.........................................................................................10
3-8. Composite, S-Video and Component Video Connections...........................................25
4-4. Typical Gray Bar Pattern for Adjusting Contrast..........................................................37
Runco PlasmaWall Owner’s Operating Manual
ix
Download from Www.Somanuals.com. All Manuals Search And Download.
List of Figures
Notes:
x
Runco PlasmaWall Owner’s Operating Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
1. Introduction
This Owner’s Manual describes how to install, set up and operate the Runco PlasmaWall
Flat-Panel Plasma Display Monitor and DHD Controller (Model PL-50XA). It describes the
features and functions available with DHD Controller Software version 2.0 and later.
1.1
About This Manual
Throughout this manual, the Runco PlasmaWall Flat-Panel Plasma Display Monitor and
DHD Controller are referred to collectively as the “PlasmaWall.”
Runco has prepared this manual to help home theater installers and end users get the
most out of the PlasmaWall.
Target Audience
Runco has made every effort to ensure that this manual is accurate as of the date it was
printed. However, because of ongoing product improvements and customer feedback, it
If You Have Comments
About This Manual...
Text Conventions: The following conventions are used in this manual, in order to clarify
the information and instructions provided:
Textual and Graphic
Conventions
• Remote control button identifiers are set in upper-case bold type; for example, “Press
EXIT to return to the previous menu.”
• All keys with functional names are initial-capped, set in bold type and enclosed in angle
brackets. These keys are the following: <Enter>, <Spacebar>, <Control>, <Esc>
and <Tab>.
• <Enter> indicates that you may press either the RETURN or ENTER key on your
computer keyboard if it has both keys.
• Computer input (commands you type) and output (responses that appear on-screen) is
shown in monospace (fixed-width) type; for example: “To change the aspect ratio to
Anamorphic, type ANAMORPHIC <Enter>.”
In addition to these conventions, underlining, boldface and/or italics are occasionally used
to highlight important information, as in this example:
A carriage return must be used after each command or string.
Note
Runco PlasmaWall Owner’s Operating Manual
1
Download from Www.Somanuals.com. All Manuals Search And Download.
Graphic Conventions: These symbols appear in numerous places throughout the
manual, to emphasize points that you must keep in mind to avoid problems with your
equipment or injury:
TIPS highlight time-saving short cuts and helpful guidelines for using
certain features.
Tip
NOTES emphasize text with unusual importance or special
significance. They also provide supplemental information.
Note
CAUTIONS alert users that a given action or omitted action can
degrade performance or cause a malfunction.
Caution
WARNINGS appear when a given action or omitted action can result
in damage to the equipment, or possible non-fatal injury to the user.
WARNING
DANGER!
DANGER appears when a given action can cause severe injury or
death.
Use the following table to locate the specific information you need in this manual.
1.2
Using This Manual
If you need...
... Turn to page:
Information about obtaining service
General information about the PlasmaWall
Flat-Panel Plasma Display Monitor and DHD Con-
troller
Installation instructions
First-time configuration instructions
Advanced configuration instructions
Troubleshooting tips
Specifications for the PlasmaWall Flat-Panel
Plasma Display Monitor and DHD Controller
2
Runco PlasmaWall Owner’s Operating Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
The PlasmaWall™ is large enough to be used as the centerpiece of any home theater, yet
slim enough (less than five inches) to be used in any type of room environment. Its size is
only one of its advantages. It also has HDTV resolution of 1365 x 768, is bright enough to
be used in any lighting situation, and can be mounted on a wall or placed on a tabletop.
1.3
Description, Features
and Benefits
The PlasmaWall is supplied with Runco’s next-generation, all-digital DHD Controller,
featuring advanced Vivix II™ processing. This controller produces stunning video imagery,
elevating even standard NTSC material to near high-definition levels.
Multiple aspect ratio control includes Runco’s VirtualWide™ for viewing 4:3 material in
widescreen with no loss of picture quality. The DHD provides for a pure digital signal path
from input to output, making this system ready for Runco’s exclusive LiveLink™ DVI cable
solution to preserve HD signal quality over long runs.
The PlasmaWall has been skillfully engineered for the finest video performance at altitudes
of up to 9,000 feet. The advanced design features both RS-232C and IR control interfaces
to accommodate custom installation and everyday operation with ease.
The PlasmaWall offers these key features and benefits:
• Native Resolution: 1365 x 768 (16:9 Native Aspect Ratio)
• Screen Size (diagonal): 50 inches
Key Features and Benefits
• Multiple Aspect Ratios with VirtualWide™ Mode
• Less than five inches deep
• HDMI Inputs with High-bandwidth Digital Content Protection (HDCP)
• HDTV Compatible
• Exceptional detail and artifact-free video enhancement
• Vivix™ video processing with 3:2 film detection circuitry
Runco PlasmaWall Owner’s Operating Manual
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Parts List
Your PlasmaWall is shipped with the following items. If any items are missing or damaged,
please contact your Runco dealer or Runco Customer Service at (800) 23-RUNCO.
➤
• PlasmaWall Flat-Panel Plasma Display Monitor and DHD Controller
• AC Power Cords (2)
• Remote Control Unit and two (2), AAA-size batteries
• RJ-11 Telephone Cable, 50 feet (15.24 meters)
• Serial Port Adapter, RJ-11 Female to DB-9 Female
• Rack-mount hardware for the DHD Controller
• Warranty information and registration card
• Runco PlasmaWall Owner’s Operating Manual (this document)
• Ferrite cores (2)
• Cable Clamps
Optional Accessories:
• Wall Mount Kit
• Table Stand
4
Runco PlasmaWall Owner’s Operating Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
2. Controls and Functions
2.1
PlasmaWall at a
Glance
Figure 2-1 shows the locations of the PlasmaWall front-panel controls and indicators.
Controls and Indicators
Located on bottom
of Plasma
Located on bottom
of Plasma
VOLUME
DOWN
INPUTSELECT
/EXIT
MENU / ENTER
UP
LEFT/-
RIGHT/+
6
5
4
1
3
2
7
Figure 2-1. PlasmaWall Front-Panel Controls and Indicators
1. POWER BUTTON
Turns the monitor’s power on and off.
2. REMOTE CONTROL SENSOR
Receives the signals from the remote control.
3. POWER/STANDBY INDICATOR
- Lights red to indicate that the PlasmaWall is in standby mode;
- Lights green to indicate normal operation;
- Flashes red to indicate that the internal temperature is too high.
Runco PlasmaWall Owner’s Operating Manual
5
Download from Www.Somanuals.com. All Manuals Search And Download.
4. INPUT SELECT/EXIT
Not used with this model. Use the DHD Controller to select an input source.
5. LEFT/– and RIGHT/+
Not used with this model.
6. VOLUME DOWN and UP
Not used with this model.
7. MENU/ENTER
Not used with this model. Use the DHD Controller to access the on-screen menus.
The Power on/off switch does not disconnect the plasma display
completely from the supply mains.
WARNING
Connectors
Figure 2-2 shows the locations of the PlasmaWall connectors.
➤
3
4
5
6
AC IN
RIGHT
LEFT
+
+
-
-
7
8
9
2
1
10
Figure 2-2. PlasmaWall Connectors
6
Runco PlasmaWall Owner’s Operating Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
1. POWER INPUT (100 to 240 VAC)
Connect the PlasmaWall to power here, using the included power cord.
2. EXTERNAL SPEAKER OUTPUTS
Not used. Connect speakers to an external audio amplifier/receiver.
3. VIDEO1, 2 (RCA, S-Video)
Not used. Connect all video sources to the DHD Controller.
4. AUDIO1, AUDIO2, AUDIO3
Not used with this model. Connect the audio outputs from your sources to an external
audio receiver.
5. DVD/HD1
DVD/HD2
Not used. Connect all video sources to the DHD Controller.
6. PC/RGB (15-pin D-Sub)
Connect the RGBHV (5xBNC) output from the DHD Controller here.
7. DVD/HD3, DVD/HD4 (HDMI)
HDCP-compliant digital video inputs. Connect the DVI output from the DHD Controller
to the DVD/HD3 input. (DVD/HD4 is not used.)
8. EXTERNAL CONTROL (9-pin, male D-Sub)
A male, 9-pin D-sub connector. Connect the RS-232 OUT port on the DHD Controller
to this input.
9. REMOTE IN (3.5-mm mini phone jack, tip/ring/sleeve)
Wired input from an external remote control or infrared (IR) receiver.
10. REMOTE OUT (3.5-mm mini phone jack, tip/ring/sleeve)
Wired output to the REMOTE IN jack of another device; allows you to control both the
PlasmaWall and the other device using the same wired remote control.
Runco PlasmaWall Owner’s Operating Manual
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 2-3 shows the controls and indicators on the DHD Controller front panel; the
paragraphs that follow describe them.
2.2
DHD Controller Front
Panel
2
4
5
6
8
9
1
3
7
10
Figure 2-3. DHD Controller Front Panel
1. RUNCO ICON
Lights red to indicate that the DHD Controller is in standby mode; lights blue to
indicate that the unit is on.
2. POWER BUTTON
Press once to toggle from standby mode to on mode. Press it again to return to
standby mode. For a discrete on or off command, you can use the direct access
buttons on the remote control.
3. IR SENSOR
Receives IR commands from the remote.
4. VACUUM FLUORESCENT DISPLAY
Can be used instead of the On-Screen Display (OSD). Displays currently-selected
menu or – if no menu is selected – the current source, signal format (NTSC or PAL),
input resolution and aspect ratio.
8
Runco PlasmaWall Owner’s Operating Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
5. UP BUTTON
Use to direct-select aspect ratios or move the menu cursor up in the On-Screen
Display. When no menus are present on-screen, the UP button toggles you through
aspect ratios in the following order:
Anamorphic - Standard (4:3) - Letterbox - VirtualWide - Cinema
(For more information about aspect ratios, refer to Table 4-1.)
6. LEFT BUTTON
Used to direct select inputs or move the menu cursor left in the On Screen Display.
When no menu is present on-screen, the LEFT button toggles you through the
different sources, in this order:
HD Pass Thru 2 - HD Pass Thru 1 - DVI 2 - DVI 1 - HD/RGB2 - HD/RGB1 -
Component SD - S-Video 2 - S-Video 1 - Composite
7. ENTER BUTTON
When an item is highlighted on the On-Screen Display, the ENTER button selects the
item.
8. DOWN BUTTON
Use to direct select aspect ratios or move the menu cursor down in the On-Screen
Display. When no menu is present on-screen, this button toggles you through the
different aspect ratios, in this order:
Cinema - VirtualWide - Letterbox - Standard (4:3) - Anamorphic
9. RIGHT BUTTON
Used to direct select inputs or move the menu cursor right in the On Screen Display.
When no menus are present on-screen, the RIGHT button toggles you through the
different sources, in this order:
Composite - S-Video 1 - S-Video 2 - Component SD - HD/RGB 1 - HD/RGB 2 - DVI 1
- DVI 2 - HD Pass Thru 1 - HD Pass Thru 2
10. MENU BUTTON
Pressing the MENU button brings up the main menu. Also, if you are in an adjustment
mode or function, pressing MENU brings the menu back one level.
Runco PlasmaWall Owner’s Operating Manual
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 2-4 shows the rear connector panel on the DHD Controller.
2.3
DHD Controller Rear
Panel
8
4
10
SYSTEM CONTROL INTERFACE
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
Serial No
INPUTS
B/Pb
!
R/Pr
G/Y
H
V
AVIS: RISQUE DE CHOC ELECTRIQUE-NE PAS OUVRIR
TRIGGERS
CAUTION: TO REDUCE THE RISK OF ELECTRIC
SHOCK, DO NOT REMOVE COVER. NO USER-
SERVICEABLE PARTS INSIDE. REFER SERVICING
TO QUALIFIED SERVICE CENTER.
Runco International
Union City, CA
HD1
HD2
1
2
3
IR
Model
OUTPUTS
R/Pr
G/Y
B/Pb
Video Processor / Controller
WARNING: TO REDUCE THE RISK OF FIRE
OR ELECTRIC SHOCK, DO NOT EXPOSE
THIS APPLIANCE TO RAIN OR MOISTURE.
R/Pr
G/Y
B/Pb
H
V
SDI
Pb
Pr
Y
S-Video 1
100-230VAC 50-60 Hz, 165 Watts Max
Made In USA
H
V
H/V
DVI Out
DVI 1
DVI 2
Option
Component Video
Video
S-Video 2 RS-232 Out
RS-232 Control
1
2
9
3
5
6
7
11
12
13
14
Figure 2-4. DHD Controller Rear Panel
Outputs
Inputs
1. ANALOG OUTPUTS (RGBHV)
➤
Connect these to the PC/RGB input of the PlasmaWall, using a DB15HD-to-5 x BNC
breakout cable.
2. DVI OUT
Connect this to the DVD/HD3 input on the PlasmaWall, using a DVI-to-HDMI cable.
3. DVI 1 / DVI 2 (Digital)
➤
Two, HDCP-compliant digital video inputs for connecting a DVD player or HD tuner
with a DVI or HDMI output.
4. HD1 / HD2 (Analog BNC connectors)
Five, BNC connectors for connecting either RGB or component high-definition
television signals. The PlasmaWall automatically detects the signal format: RGB(HV)
or YPrPb, 480p, 720p, 480i, 576i or 1080i.
5. COMPONENT VIDEO (RCA connectors)
Standard Definition (480i/576i) Component (YPrPb) input. This is the input for
component video from sources such as DVD players.
For best results, do not run your DVD player in progressive mode.
Tip
10
Runco PlasmaWall Owner’s Operating Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
6. COMPOSITE VIDEO INPUT
Standard composite video input for connecting a VCR, camcorder, laser disc player
or other composite video source.
7. S-VIDEO 1 / S-VIDEO 2
Two, standard S-Video inputs for connecting a DVD player, satellite receiver or Super
VHS (S-VHS) VCR.
8. 12-VOLT (750 mA) TRIGGER OUTPUTS
Connection for up to three (3), 12-volt trigger-controlled devices.
9. RS-232 OUTPUT (6-Wire, RJ-11 jack)
Connect this to the RS-232C input of the PlasmaWall, using the supplied serial port
adapter and communication cable.
10. IR
Wired input from an external remote control or infrared receiver. It is a 3.5-mm, mini
phono jack, wired as follows:
Ring = +5V
Tip = IR Input
Sleeve = Ground
When an external remote control or infrared receiver is connected
to the wired IR input, the IR sensor on the front of the DHD
Controller is disabled.
Note
11. RS-232 CONTROL PORT
A female, 9-pin D-sub connector for interfacing with a PC or home theater
automation/control system.
12. POWER INPUT (100 to 240 VAC)
Connect the DHD Controller to power here.
13. MAIN AC FUSE
This is the main AC input fuse (5mm x 20mm, 500 mA, 250V slow-blow).
14. MAIN POWER SWITCH
Disconnects or applies power to the DHD Controller.
Runco PlasmaWall Owner’s Operating Manual
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 2-5 shows the DHD Controller remote control, and the paragraphs that follow
describe its functionality.
2.4
DHD Controller
Remote Control
2
1
3
4
6
5
8
7
10
11
9
12
13
Figure 2-5. DHD Controller Remote Control
12
Runco PlasmaWall Owner’s Operating Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
1. IR OUTPUT INDICATOR
Lights when a button is pressed to indicate that an IR signal is being transmitted.
2. ON / OFF
Press to turn the PlasmaWall on or off.
3. ENTER
Press to select a highlighted menu item or confirm a changed setting.
4. Cursor Keys (
,
,
,
)
Use these buttons to select items or settings, adjust settings or switch display
patterns.
When no menus are present on-screen, the UP and DOWN buttons toggle through
the available aspect ratios, in this order:
UP Button = Anamorphic - Standard (4:3) - Letterbox - VirtualWide - Cinema
DOWN Button = Cinema - VirtualWide - Letterbox - Standard (4:3) - Anamorphic
Likewise, the LEFT and RIGHT buttons toggle through the different source inputs, in
this order:
LEFT Button = HD Pass Thru 2 - HD Pass Thru 1 - DVI 2 - DVI 1 - HD/RGB2 -
HD/RGB 1 - Component SD - S-Video 2 - S-Video 1 - Composite
RIGHT Button = Composite - S-Video 1 - S-Video 2 - Component SD - HD/RGB 1 -
HD/RGB 2 - DVI 1 - DVI 2 - HD Pass Thru 1 - HD Pass Thru 2
5. LIGHT
Press to illuminate the buttons. (Not available on all models.)
6. MENU
Press this button to access the OSD controls, or to exit the current menu and return
to the previous one.
7. VIDEO (1)
Press to select Composite video input as the source or to enter the numeric
character “1.”
8. COMP (Component) (2)
Press to select Component SD (480i/576i) video input as the source or to enter the
numeric character “2.”
Runco PlasmaWall Owner’s Operating Manual
13
Download from Www.Somanuals.com. All Manuals Search And Download.
9. Aspect Ratio Selection Buttons
Use the red buttons to select an aspect ratio directly or to enter numeric characters,
as follows:
ANA (Anamorphic) (3)
For viewing 16:9 DVDs or HDTV programs in their native aspect ratio.
4X3 (Standard 4:3) (6)
Scales the input signal to fit 4:3 display mode in the center of the screen.
LETBOX (Letterbox) (9)
For viewing LaserDisc movies or non-anamorphic DVDs on a 4:3 screen.
V-WIDE (VirtualWide)
Enlarges a 4:3 image horizontally in a NON-linear fashion to fit 16:9 full screen display.
CINEMA
For viewing 2.35:1 source material on a 1.78:1 (16:9) screen. The upper and lower
portions are masked.
SVC
Not used.
10. S-VID 1 (4) / S-VID 2 (5) (S-Video)
Press to select an S-Video input or to enter the numeric character “4” or “5.”
11. HD 1 (7) / HD 2 (8)
Press to select a HD (RGBHV or YPbPr component) input or to enter the numeric
character “7” or “8.”
12. DVI 1 / DVI 2 (0)
Press to select a Digital Video input. Press DVI2 to enter the numeric character “0.”
13. Memory Preset Buttons:
ISF NT (Night)
Press to recall settings for the current input from the “ISF Night” memory preset.
ISF DAY
Press to recall settings for the current input from the “ISF Day” memory preset.
CUST 1
Press to recall settings for the current input from the “Custom 1” memory preset.
CUST 2
Press to recall settings for the current input from the “Custom 2” memory preset.
14
Runco PlasmaWall Owner’s Operating Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Installation
To install batteries in the remote control:
3.1
Remote Control
1. Press down the tab on the cover and
pull the cover in the direction of the
arrow.
2. Insert the included batteries. Ensure
that the polarities correctly match the
and
markings inside the battery
compartment.
3. Insert the lower tab of the cover into the
opening, and press down the cover until
it clicks in place.
• When installing batteries, make sure that the battery polarities are correct.
• Do not mix an old battery with a new one or different types of batteries.
Notes on Batteries
• If you will not use the remote control for a long time, remove the batteries to avoid
damage from battery leakage.
The remote control can be used to control the PlasmaWall within the ranges shown in
Notes on Remote Control
Operation
Approx.
7m/23ft
Figure 3-1. Available Range of the Remote Control
Runco PlasmaWall Owner’s Operating Manual
15
Download from Www.Somanuals.com. All Manuals Search And Download.
• Do not drop the remote control or expose it to moisture or high temperature.
• The remote control may malfunction under a fluorescent lamp. If that occurs, move the
plasma display away from the fluorescent lamp.
• Make sure that there is nothing obstructing the infrared beam between the remote
control and the IR receiver on the plasma display.
The signal from the remote control can be reflected by walls or
other surfaces.
Note
• If the effective range of the remote control decreases, or it stops working, replace the
batteries with new ones.
• Ambient conditions may possibly impede the operation of the remote control. If this
happens, point the remote control at the plasma display and repeat the operation.
16
Runco PlasmaWall Owner’s Operating Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 3-1 gives a quick overview of the PlasmaWall installation process. The sections
following this one provide detailed instructions.
3.2
Quick Setup
Installation should be performed by a qualified custom video
installation specialist.
Note
Table 3-1. Installation Overview
For Details, refer to
page...
Step
Procedure
1
2
3
4
Mount the PlasmaWall on a wall or table stand
Connect the DHD Controller to the PlasmaWall
Connect signal sources to the DHD Controller
Connect external controller to DHD Controller RS-232 port
(optional)
5
6
Apply power to the PlasmaWall
29
If using the PlasmaWall with a PC, adjust PC display prop-
erties
7
Display calibration: adjust the following for each input,
starting with Component SD; save settings when finished:
• Aspect ratio
• Brightness
• Contrast
• Color level
• Tint
• Sharpness
Runco PlasmaWall Owner’s Operating Manual
17
Download from Www.Somanuals.com. All Manuals Search And Download.
Proper installation of your PlasmaWall will ensure the highest possible picture quality.
Whether you are installing the PlasmaWall temporarily or permanently, you should take the
following into account to ensure that it performs optimally.
3.3
Installation
Considerations
Mounting the PlasmaWall
on a Wall or Table Stand
To install the PlasmaWall, you will need either an optional table stand or wall-mounting kit.
The PlasmaWall cannot be installed on its own.
➤
If you do decide to wall-mount the PlasmaWall, ensure that the wall-mount bracket is
installed according to the instructions included with it. The wall must be capable of
supporting a redundant weight factor three (3) times the weight of the display, or be
reinforced.
Runco recommends that this be done by a custom installation specialist.
Use only a Runco-approved wall-mount kit or table stand that is
specifically designed for your display.
Note
You can attach your optional mounts or stand to the PlasmaWall in either of two ways:
• While it is upright.
• As it lies flat with the screen face
down. Place the protective sheet,
which was wrapped around the
plasma monitor when it was
packaged, between the screen and
your work surface to avoid
scratching or otherwise damaging
the screen surface.
Ambient Light
In general, minimize or eliminate light sources directed at the display. Contrast ratio in your
images will be noticeably reduced if light directly strikes the display, such as when a shaft
of light from a window or floodlight falls on the image. Images may then appear washed
out and less vibrant.
➤
18
Runco PlasmaWall Owner’s Operating Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
If you are mounting the PlasmaWall in an enclosure, leave at least 2 inches (50 mm) of
heat to disperse, maintaining the proper operating temperature.
Ventilation
Wall
50mm (2")
50mm (2")
Wall
50mm (2")
Figure 3-2. Ventilation Requirements for Enclosure Mounting
Other considerations and tips that can help improve your installation, avoid damage and
prolong operating life:
Other Considerations
• Keep the ambient temperature constant and below 35°C (95°F). Keep the display away
from heating and/or air conditioning vents. Changes in temperature may cause drifts in
the display circuitry, which may affect performance.
• Keep the PlasmaWall away from devices that radiate electromagnetic energy such as
motors and transformers. Common sources of these include slide projectors,
speakers, power amplifiers and elevators.
• Handle the unit carefully when installing or carrying it. Use the built-in handles; DO NOT
touch or hold the screen face.
• Set the unit away from heat, excessive dust, and direct sunlight.
• Protect the inside of the unit from liquids and small metal objects. In case of accident,
unplug the power cord and have it serviced by an authorized Service Center.
• Do not hit or scratch the panel surface as this causes flaws on the surface of the
screen.
• For correct installation and mounting it is strongly recommended to use a trained,
authorized dealer.
• To avoid sulfurization, it is strongly recommended not to place the unit in a dressing
room in a public bath or hot spring bath.
Runco PlasmaWall Owner’s Operating Manual
19
Download from Www.Somanuals.com. All Manuals Search And Download.
Proceed as follows to connect the PlasmaWall to the DHD Controller, your video sources,
external controller(s) – if present – and AC power.
3.4
Connections to the
PlasmaWall and DHD
Controller
When connecting your equipment:
• Turn off all equipment before making any connections.
• Use the correct signal cables for each source.
• Ensure that the cables are securely connected. Tighten the thumbscrews on
connectors that have them.
• Use the left audio input when connecting mono audio sources.
Connecting the
PlasmaWall to the DHD
Controller
the sections that follow.
➤
DHD Controller
SYSTEM CONTROL INTERFACE
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
Serial No
INPUTS
B/Pb
!
R/Pr
G/Y
H
V
AVIS: RISQUE DE CHOC ELECTRIQUE-NE PAS OUVRIR
TRIGGERS
2
CAUTION: TO REDUCE THE RISK OF ELECTRIC
SHOCK, DO NOT REMOVE COVER. NO USER-
SERVICEABLE PARTS INSIDE. REFER SERVICING
TO QUALIFIED SERVICE CENTER.
Runco International
Union City, CA
HD1
1
3
IR
Model
OUTPUTS
G/Y
HD2
R/Pr
B/Pb
Video Processor Controller
/
WARNING: TO REDUCE THE RISK OF FIRE
OR ELECTRIC SHOCK, DO NOT EXPOSE
THIS APPLIANCE TO RAIN OR MOISTURE.
R/Pr
G/Y
B/Pb
H
V
SDI
Pb
Pr
Y
S-Video
S-Video
1
2
100-230VAC 50-60 Hz, 165 Watts Max
Made In USA
H
V
H/V
DVI Out
DVI
1
DVI
2
Option
Component Video
Video
RS-232 Out
RS-232 Control
RGB-HV
OUT
DVI
OUT
RS-232
OUT
PC/
RGB
DVD/HD3
EXTERNAL
CONTROL
(RS-232)
Figure 3-3. Connecting the PlasmaWall to the DHD Controller
20
Runco PlasmaWall Owner’s Operating Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Digital Video Connection: The PlasmaWall has two HDMI inputs. Connect the DVI
output from the DHD Controller to the DVD/HD3 input, using a DVI-to-HDMI cable.
RGB-HD Connection: Connect the RGBHV output from the DHD Controller to the
PC/RGB input on the PlasmaWall. Use a VGA-to-RGBHV breakout cable with 5 BNC
connectors on the DHD end and a standard, 15-pin, male VGA connector on the
PlasmaWall end.
RS-232 (External Control) Connection: Connect the RS-232 output from the DHD
Controller to the EXTERNAL CONTROL input on the PlasmaWall. Use a standard,
modular telephone cable with RJ11 plugs at both ends. On the PlasmaWall end, use an
XMT DATA
RCV DATA
SIG GND
RCV DATA
XMT DATA
2
3
5
4
3
SIG GND
2, 5
REQUEST TO SEND
CLEAR TO SEND
DATA TERMINAL READY
DATA SET READY
To/From
DHD
Controller
7
8
4
6
1
5
6
9
NO CONNECTION
1, 6
1, 9
DB-9 Female
RJ-11 Male
Figure 3-4. RS-232 Connection from the DHD Controller to the PlasmaWall
Runco PlasmaWall Owner’s Operating Manual
21
Download from Www.Somanuals.com. All Manuals Search And Download.
Connecting Source
Components to the DHD
Controller
Connect your video sources to the DHD Controller as shown and described in the
sections that follow.
➤
Use the DVI inputs whenever possible. This ensures the highest
Tip
video quality because the signal is carried in the digital domain
throughout the entire signal path, from source component output
into the display.
INPUTS
R/Pr
G/Y
B/Pb
H
V
TRIGGERS
2
HD1
HD2
1
3
IR
R/Pr
G/Y
B/Pb
H
V
Pb
Pr
Y
S-Video 1
DVI 1
DVI 2
Component Video
Video
S-Video 2
DVI Source
(DVD Player or
HD Tuner with
HDMI or DVI out)
Figure 3-5. DVI Source Connections
22
Runco PlasmaWall Owner’s Operating Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
INPUTS
R/Pr
G/Y
B/Pb
H
V
TRIGGERS
2
HD1
HD2
1
3
R/Pr
G/Y
B/Pb
H
V
S-Video 1
Pb
Pr
Y
Video
S-Video 2
DVI 1
DVI 2
Component Video
Red/Pr Green/Y Blue/Pb
Horiz
Vert
DTV or Progressive
Component (YPbPr)
Source
Figure 3-6. Digital (DTV) RGB Connections
Runco PlasmaWall Owner’s Operating Manual
23
Download from Www.Somanuals.com. All Manuals Search And Download.
Note
a list of computer signals compatible with the PlasmaWall. Use
with signals other than those listed may cause some functions not
to work.
2. Some Macintosh computers may require a Macintosh video
adapter. Contact your nearest authorized service center or dealer.
INPUTS
R/Pr
G/Y
B/Pb
H
V
TRIGGERS
2
HD1
HD2
1
3
R/Pr
G/Y
B/Pb
H
V
S-Video 1
Pb
Pr
Component Video
Y
Video
S-Video 2
DVI 1
DVI 2
Red Green Blue Horiz Vert
Personal Computer
Figure 3-7. Analog RGB Connections
24
Runco PlasmaWall Owner’s Operating Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
INPUTS
R/Pr
G/Y
B/Pb
H
V
TRIGGERS
2
HD1
HD2
1
3
R/Pr
G/Y
B/Pb
H
V
S-Video 1
Pb
Pr
Component Video
Y
Video
S-Video 2
DVI 1
DVI 2
Pb Pr
Y
DVD Player, VCR,
Satellite Receiver,
Laser Disc etc.
Figure 3-8. Composite, S-Video and Component Video Connections
Runco PlasmaWall Owner’s Operating Manual
25
Download from Www.Somanuals.com. All Manuals Search And Download.
RS-232 Controller
Connection
Use a standard, 9-pin RS-232 cable to connect a PC or home theater control/automation
➤
5
4
3
1
2
TRIGGERS
2
6
9
8
7
1
3
IR
Pb
Pr
Y
S-Video 1
2 Transmit Data
3 Receive Data
5 Ground
Component Video
Video
S-Video 2 RS-232 Out
RS-232 Control
(none of the other pins are used)
to Automation/
Control System
or PC
Figure 3-9. RS-232 Control System Connection
Connecting 12-Volt
Trigger Outputs to
External Theater
Components
If your home theater contains equipment that responds to 12-volt triggers, connect them
➤
TRIGGERS
1
2
3
IR
Pb
Pr
Y
S-Video 1
Component Video
Video
S-Video 2 RS-232 Out
RS-232 Control
3.5-mm
mini plug
to 12-Volt
trigger-activated
equipment
Figure 3-10. Connecting 12-Volt Trigger Outputs
26
Runco PlasmaWall Owner’s Operating Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
To minimize cable clutter, use the cable clamps provided with the PlasmaWall to bundle
the video, audio and control cables at the back of the display. Install the clamps as shown
Cable Management
Back of the unit
mounting holes
To attach
1.
2.
clamp
cables
mounting hole
To detach
Figure 3-11. Installing the Cable Clamps
Runco PlasmaWall Owner’s Operating Manual
27
Download from Www.Somanuals.com. All Manuals Search And Download.
Notes:
28
Runco PlasmaWall Owner’s Operating Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Operation
1. Turn on your source components.
4.1
Turning on the Power
2. Attach the two ferrite cores supplied with the display to each end of the AC power
emissions to a level that conforms to FCC regulations. Use the supplied plastic bands
to secure the cores in place.
Power cable
Ferrite Core
Ferrite Core
Figure 4-1. Attaching the Ferrite Cores to the Power Cable
3. Plug the female end of the power cord into the AC receptacle on the rear of the
PlasmaWall (AC 100V ~ 240V). Connect the other end to your AC power source.
4. Similarly connect the DHD Controller to a nearby AC outlet.
5. Press the POWER button on the underside of the PlasmaWall. Its power indicator
lights green.
6. Turn on the main power switch at the rear of the DHD Controller.
7. Press the ON button on the remote control to
turn on the DHD Controller (or press the power
button on the front of the DHD Controller). The
power indicator on the DHD Controller lights
solid blue.
8. After a brief warm-up period (approximately 10
seconds), the PlasmaWall will display an image.
Runco PlasmaWall Owner’s Operating Manual
29
Download from Www.Somanuals.com. All Manuals Search And Download.
By default, the PlasmaWall is configured to display the signal received on its RGBHV
(PC/RGB) input. To use the HDMI (DVD/HD3) input instead:
4.2
Selecting the Input
Source
1. Press MENU and enter the Service Menu passcode.
You must enter a passcode to access the Service menu.
Note
2. Select Service from the Main Menu.
3. Select Display Device from the Service Menu.
4. Press
to select DVI/HDMI, then press ENTER.
To maximize image quality when using the PlasmaWall with a personal computer, you
may need to adjust the display properties of your PC video card. To do this:
4.3
Setting the PC Display
Properties
1. Choose Settings from the Windows Start
menu and click on “Control Panel.”
2. Double click on the Display icon.
3. Click the Settings tab on the display dialog
box.
4. Adjust the resolution to 1024x768 pixels.
30
Runco PlasmaWall Owner’s Operating Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
5. Click the Advanced button and click the
Monitor tab on the dialog box. Set the
vertical frequency to 60Hz and click OK.
1. The native resolution of the PlasmaWall is 1365 x 768. Other
horizontal or vertical resolutions may be scaled upward or
downward to fit the display.
Note
2. With most computers, you can get the best picture at
1024 x 768 @ 60Hz.
3. For best results when using a computer, set the input on the
DHD Controller to HD Pass Thru 1 or HD Pass Thru 2, depending
on which RGB/HD input you are using.
4. The PlasmaWall supports 36-bit color (68.7 billion possible
colors).
To prevent image retention (burn) on your display, ALWAYS use a
screen saver and set it to the shortest possible time.
WARNING
Runco PlasmaWall Owner’s Operating Manual
31
Download from Www.Somanuals.com. All Manuals Search And Download.
Press the MENU button on either the remote control or the DHD Controller front panel to
display the Main Menu. To select a menu item, use the UP ( ) and DOWN ( ) buttons
on either the remote control or the DHD Controller front panel to highlight it. Press ENTER
4.4
Using the On-Screen
Menus
to confirm your selection.
Depending on the selected input source and signal characteristics, some menu options
may not be available.
32
Runco PlasmaWall Owner’s Operating Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Composite
S-Video 1
S-Video 2
Component SD
HD/RGB 1
HD/RGB 2
DVI 1
Gain
ISF Night - Display Color
ISF Night - Input Image
Offset
Brightness
Contrast
Color
Tint
Input Source
Sharpness
Gain
DVI 2
HD Pass Thru 1/
Offset
HD Pass Thru 2
(available only when Display Device
Input Source = RGBHV)
ISF Night - Input Color
ISF Day - Display Color
ISF Day - Input Image
Chroma Delay
Phase
Noise Filter
Gain
Anamorphic
Standard 4:3
Letterbox
Offset
Aspect Ratio
Picture
Brightness
Contrast
Color
VirtualWide
Cinema
Brightness
Tint
Calibration
Contrast
Sharpness
Gain
Color
Tint
Offset
Sharpness
ISF Day - Input Color
Save ISF Settings
Output Shift
Chroma Delay
Phase
Left/Right
Up/Down
Noise Filter
Back / Confirm
Left/Right
Up/Down
Width
Width
Input Position
ISF Presets
Height
Overscan
Recall ISF Night
Recall ISF Day
Recall/Save Custom 1
Recall/Save Custom 2
Reset Custom 1 & 2 to Factory Default
Serial Number
Hardware
Height
Save
Owner Name
ISF Calibrated
ISF Other
Splash Enable
Splash Configure
OSD Position
Information
Firmware
(read-only)
Date
Grey Bars 1
Grey Bars 2
Test Video
Color Bars 1
Color Bars 2
Input Names
Rename, Restore or Save
Primary
Remote Control
Analog Out Mode
Secondary
RGB--, RGB++ or RGBS
Input Source
RGB or DVI/HDMI
Inverse
Left/Right
Up/Down
Width
Display Device
Configure
Height
Service
Noise Filter
HD/RGB 1
Auto, RGB or YUV
HD/RGB 2
HD Format
Triggers
ADC Bandwidth
YPbPr Input Resolution
1 / 2 / 3 / Save
Language
Auto, 75 MHz, 150 MHz or 300 MHz
Auto, 480i/p, 576i/p, 720p or 1080i
(currently, English only)
Menu Mode
Miscellaneous
Timeout
Side Bar Color
Film Mode (SD src. only)
800x600 ... 1400x1050
480p ... 720p ... 1080i
Resolution
System Reset
Restore Saved Settings
Figure 4-2. DHD Controller OSD Menu Structure for PlasmaWall
Runco PlasmaWall Owner’s Operating Manual
33
Download from Www.Somanuals.com. All Manuals Search And Download.
Main Menu
The Main Menu is the starting point for accessing all display functions.
➤
(The Calibration and Service menus are hidden and not accessible until you enter a
passcode.)
Runco Video
Input Source
Aspect Ratio
Picture
Input Position
ISF Presets
Information
Calibration
Service
Input Source
From the Main Menu, select Input Source to choose a video signal source.
➤
The active source is indicated by an arrow (>) to its left; in the example at left, Composite
is the active source.
Input Source
Composite
>
S-Video 1
1. HD Pass Thru 1 and HD Pass Thru 2 are available only when the
Display Device Input Source is set to “1” (RGBHV); refer to
S-Video 2
Note
Component SD
HD/RGB 1
HD/RGB 2
DVI 1
2. Selecting HD Pass Thru 1 or HD Pass Thru 2 loops the
HD/RGB 1 or HD/RGB 2 input signal respectively to the RGB
output. This prevents display of the on-screen menus. To switch
from HD Pass Thru 1 or 2 to another source, use the direct
access buttons on the remote control, or the left- or right-arrow
buttons on the DHD Controller.
DVI 2
HD Pass Thru 1
HD Pass Thru 2
3. If the DVI 1 or DVI 2 input is active and the input signal is
HDCP-encrypted, the RGBHV output of the DHD Controller is
disabled.
Aspect Ratio
To change the aspect ratio (size and shape) of the projected image, select Aspect Ratio
from the Main Menu and press ENTER. Select the appropriate aspect ratio for your
➤
Aspect Ratio
Anamorphic
7
ꢀ
ꢀ
ꢀ
ꢀ
The currently-selected aspect ratio is indicated by a “7” to its left; in the example at left,
Anamorphic is selected.
Standard 4:3
Letterbox
VirtualWide
Cinema
The aspect ratio selection is automatically saved for each input and
resolution.
Note
34
Runco PlasmaWall Owner’s Operating Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 4-1. Aspect Ratio Settings
Remote
Aspect Ratio
Control
Key
Description
Anamorphic
ANA
Select Anamorphic to view 16:9
DVDs and HDTV programs in
their native aspect ratio. 4:3
images are stretched
16:9 Image on
16:9 Screen
horizontally to fit a 16:9 screen.
4:3 Image on
16:9 Screen
Standard 4:3
4X3
Standard 4:3 scales the input
signal to fit in the center of the
16:9 screen. 4:3 is the aspect
ratio used by computer
monitors, standard television
programming and most VHS
video cassettes.
Active Image
Area (4:3)
Letterbox
LET
BOX
In Letterbox mode, the image is
stretched vertically; the top and
bottom portions are “blanked
off.” Letterbox is best suited for
viewing LaserDisc movies or
non-anamorphic DVDs on a 4:3
screen.
Letterbox Image on
16:9 Screen
VirtualWide
V-WIDE
A 4:3 image is scaled
NON-linearly (more on the sides
than in the center) to fit a 16x9
screen.
Cinema
CINEMA
Select Cinema to view 2.35
source material on a 16:9
screen. The upper and lower
portions of the screen are
masked, but the geometry of the
active image area is not
changed.
2.35:1 Image on
16:9 Screen
Runco PlasmaWall Owner’s Operating Manual
35
Download from Www.Somanuals.com. All Manuals Search And Download.
Picture
Use the controls in the Picture Menu to calibrate your PlasmaWall for optimum picture
quality.
➤
Picture
The PlasmaWall has been designed to incorporate setup and calibration standards
established by the Imaging Science Foundation (ISF). The ISF has developed carefully
crafted, industry-recognized standards for optimal video performance and has
implemented a training program for technicians and installers to use these standards to
obtain optimal picture quality from Runco video display devices. Accordingly, Runco
recommends that setup and calibration be performed by an ISF certified installation
technician.
Brightness
Contrast
Color
Tint
Sharpness
All signal types require separate processing. Therefore, you need to calibrate each DHD
Controller input separately. Runco recommends calibrating the inputs in this order:
1. Component SD
2. S-Video 1 / S-Video 2
3. Composite
4. HD/RGB 1 / HD/RGB 2
5. DVI 1 / DVI 2
When you change a picture quality setting, save the change to a
Note
preset afterwards. Otherwise, the change will be lost when a
different input is selected. (Picture quality settings are saved for
each input separately.) For information about saving settings, refer
Although it may be possible to obtain satisfactory picture quality using the naked eye and
regular program material, Runco recommends using the following calibration tools for best
results:
• External test pattern source – Ovation Multimedia, Video Essentials or AVIA test DVD
(or equivalent).
• A blue filter (provided with many test DVDs), for color level and tint adjustments.
Connect your test pattern source to the input that you are calibrating and proceed as
follows. Perform the adjustments in the order listed here.
Brightness: On your external test pattern source, select a PLUGE pattern. (PLUGE is an
pattern.
Below Black
Above Black
Figure 4-3. Typical PLUGE Pattern for Adjusting Brightness
36
Runco PlasmaWall Owner’s Operating Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
PLUGE patterns vary but generally consist of some combination of black, white and gray
areas against a black background. The example above includes two vertical bars and four
shaded boxes.
Select Brightness from the Picture menu and press ENTER. Adjust the brightness so that:
• The darkest black bars disappear into the background.
• The dark gray areas are barely visible.
• The lighter gray areas are clearly visible.
• The white areas are a comfortable level of true white.
• The image contains only black, gray and white (no color).
Contrast: On your external test pattern source, select a stepped, gray-bar pattern like the
Figure 4-4. Typical Gray Bar Pattern for Adjusting Contrast
Select Contrast and press ENTER. Adjust the contrast to a point just below which the
white rectangle starts to increase in size.
Brightness and contrast controls are interactive. A change to one
may require a subtle change to the other in order to achieve the
optimum setting.
Note
Runco PlasmaWall Owner’s Operating Manual
37
Download from Www.Somanuals.com. All Manuals Search And Download.
Color Saturation: On your external test pattern source, select a color bar pattern like the
Figure 4-5. Typical Color Bar Pattern for Adjusting Color Saturation and Tint
Select Color and press ENTER. While looking at the color bar pattern through a blue filter,
adjust the color saturation level until the outermost (gray and blue) color bars appear to be
a single shade of blue:
Tint: Tint or “hue” is essentially the ratio of red to green in the color portion of the image.
When tint is decreased, the image appears redder; when it is increased the image
appears greener. To set the tint, select Tint and press ENTER. While looking at the color
bar pattern through a blue filter, adjust the tint level until the cyan and magenta color bars
(on either side of the green bar) appear to be a single shade of blue.
Like the brightness and contrast controls, the color and tint controls
are interactive. A change to one may require a subtle change to the
other in order to achieve the optimum setting.
Note
38
Runco PlasmaWall Owner’s Operating Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Sharpness: “Sharpness” is the amount of high-frequency detail in the image. To adjust
sharpness, select Sharpness from the Picture menu and press ENTER. On your external
looking for white edges around the transitions from black to gray and differently-sized lines
in the “sweep” patterns at the top and bottom. Lower the sharpness setting to eliminate
them.
Figure 4-6. Typical Test Pattern for Adjusting Sharpness
Use the controls in the Input Position Menu to fine-tune the aspect ratio and image
position for the current source.
Input Position
Input Position
Left/Right
The input position settings are automatically saved for each input
and resolution.
Up/Down
Width
Note
Height
Left/Right: Select Left/Right from the Input Position menu to shift the projected image
horizontally. Use the right or up cursor button to shift the image to the right; use the left or
down button to shift it to the left.
Overscan
Up/Down: Select Up/Down from the Input Position menu to shift the projected image
vertically. Use the right or up cursor button to shift the image upward; use the left or down
button to shift it downward.
Width: Select Width from the Input Position menu to change the projected image width.
Use the right or up cursor button to increase the width; use the left or down button to
decrease it.
Height: Select Height from the Input Position menu to change the projected image
height. Use the right or up cursor button to increase the height; use the left or down
button to decrease it.
Runco PlasmaWall Owner’s Operating Manual
39
Download from Www.Somanuals.com. All Manuals Search And Download.
Overscan: Image Overscan pushes the outside edge of the active picture area of the
video signal out beyond the edge of the display area.
Some television programs are produced based on the assumption that older television
sets may not display the outer edges of the broadcast picture area. Over scan effectively
trims away these inactive, outer edges and enlarges the remaining portion of the image to
fill the display area.
Select from 1% to 10% of Overscan, as desired.
For HDTV, DVDs and other video sources, Overscan is generally not necessary or
desirable.
ISF Presets
For each input, the PlasmaWall lets you save image quality settings as presets that you
can recall at a later time. You can create up to four presets per input and resolution. Use
the ISF Presets menu to recall saved image presets, or to save image settings in the
“Custom 1” or “Custom 2” memory location. The currently-selected preset is indicated by
a “7” to its left; in the example shown here, ISF Night is selected.
➤
ISF Presets
ISF Night
7
ꢀ
ꢀ
ꢀ
ISF Day
You should save changes to any of the following settings to a preset; otherwise they will
be lost when a new input source or resolution is selected:
Custom 1
Custom 2
Save
Save
• Brightness
• Contrast
Factory Default
• Color saturation
• Tint
• Sharpness
To reset the Custom 1 and Custom 2 image presets to their factory defaults, select
Factory Default and press ENTER.
Information
Select Information from the Main Menu to see information that uniquely identifies your
display: its serial number, the installed hardware and firmware versions and the firmware
version build date. Should you ever need to contact Runco Technical Support, this
information will help them answer your questions or resolve product performance issues.
➤
Information
Serial Number
Hardware
Firmware
Date
0
0002.002B
Mar 24 2006
40
Runco PlasmaWall Owner’s Operating Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Use the Calibration menu to perform advanced picture quality adjustments. This menu
should be used by ISF-certified technicians only.
Calibration
Calibration
ISF Night
You must enter a passcode to access the Calibration menu.
Note
Display Color
Input Image
Input Color
To recall the ISF Night or ISF Day settings, select “ISF Night” or “ISF Day” from the ISF
Presets menu (see above).
ISF Day
Display Color
Input Image
Input Color
ISF Night - Display Color: Use the Display Color settings to adjust the color balance at
the display device (as opposed to the DHD Controller). These settings are saved
independently for each input.
Save ISF Settings
Output Shift
Splash Configure
OSD Position
• Gain: Use the Gain controls to correct color imbalances in the bright areas of the
image. A good way to do this is to use a test pattern consisting mostly of solid white
areas, such as an 80 IRE “window” pattern. If the white areas contain traces of red,
green or blue, decrease the Gain for that color.
• Offset: Use the Offset controls in the White Balance sub-menu to correct color
imbalances in the dark areas of the image. A good way to do this is to use a test
pattern consisting mostly of dark gray areas, such as a 30 IRE “window” pattern. If the
gray areas contain traces of red, green or blue, decrease the Offset for that color.
menu, but are accessible only by entering the Calibration menu passcode. This makes it
possible to restore the picture quality settings to what they were when the display was
installed, simply by recalling the “ISF Night” preset.
ISF Night - Input Color: The Input Color controls are similar to those in the Display Color
menu (see above), but adjust the color balance at the DHD Controller (as opposed to the
display device). These settings are also saved independently for each input.
• Chroma Delay: use the Chroma Delay control to correct a mis-aligned image from a
Composite, S-Video or Component video source. Chroma delay in an image causes
color shifts to occur to the left of the vertical edge transitions, producing artificial
shadows or a “halo” effect. If necessary, adjust this setting to eliminate them.
• Phase: Adjust the phase if the image (usually from an RGB source) shows shimmer or
“noise.” Pixel phase adjusts the phase of the pixel sampling clock relative to the
incoming signal. The effect of this control is similar to that of a tracking control on a
VCR.
For best results, use a good test pattern such as a smooth gray consisting of a clear
pattern of black and white pixels, or a similar “half on, half off” graphic image. (You may
notice that you can stabilize the image at more than one point. Use either setting in this
case.)
• Noise Filter: To apply noise filtering to the input signal, select Noise Filter from the
Input Color menu. The Noise Filter is useful for clearing up noisy images from 480i
video sources.
Use the left- or right-arrow buttons to select the desired amount of noise reduction,
keeping in mind that higher settings (which reduce high frequencies) may also “soften”
the image.
Runco PlasmaWall Owner’s Operating Manual
41
Download from Www.Somanuals.com. All Manuals Search And Download.
Save ISF Settings: Whenever you make a change to the ISF settings, you should always
save it. Select Save ISF Settings from the ISF Calibration menu to do this. In the event you
Position menu, except that they change the characteristics of the output signal. These
settings are saved independently for each aspect ratio.
Splash Configure: Use the Splash Configure menu to customize the appearance of the
start-up message that appears on the vacuum fluorescent display upon power-up. You
can have the PlasmaWall display the owner’s name, your name, the phrase “ISF
Calibrated” and/or any other string, up to 20 characters in length.
Use the up or down cursor button to select a character. Use the right and left cursor
buttons to change the cursor position. Press MENU when you have finished entering text.
Then, check the “Splash Enable” box to have the PlasmaWall display the information you
enter here when it is turned on.
OSD Position: Select OSD Position, press ENTER and use the arrow buttons to change
the size and position of the OSD controls.
Service
Use the Service menu to access advanced display configuration settings. This menu
should be used by ISF-certified technicians only.
➤
Service
Test Video
You must enter a passcode to access the Service menu.
Note
Input Names
Remote Control
Analog Out Mode
Display Device
HD Format
Test Video: Select Test Video from the Service Menu to access the internal test patterns
on the PlasmaWall. Four patterns are available, consisting of white/gray or colored bars.
These are useful for calibrating other theater source components (DVD player, HD tuner
etc.) that have their own picture controls.
Triggers
Miscellaneous
Resolution
System Reset
Press MENU to exit test pattern mode.
Restore Saved Settings
42
Runco PlasmaWall Owner’s Operating Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Input Names: You can give each DHD Controller input a descriptive name. For example,
you may want to change the default input name to the type of source component
connected to it: “VCR,” “DVD,” “Laptop” et cetera. Composite, S-Video and Component
SD input names can be up to 12 characters long; the others can be up to eight characters
long.
Input Names
Restore
Composite
S-Video 1
S-Video 2
Composite
S-Video 1
S-Video 2
To edit an input name, select Input Names from the Service menu. Press or to select
an input and press ENTER. Use the
to select a character to change. When you have finished editing the input name, press
MENU.
or
buttons to change a character; press
or
Component SD Component SD
HD/RGB 1
HD/RGB 2
DVI 1
HD/RGB 1
HD/RGB 2
DVI 1
To restore the default input name, press
“Restore” column. Then, press ENTER.
repeatedly to highlight that input name in the
DVI 2
DVI 2
Save
To save input names so that they can be restored after a System Reset (described on
page 45), press
repeatedly to highlight “Save.” Then, press ENTER.
The button takes you from top to bottom in the left column, then
from top to bottom in the right column. To highlight “Save,” scroll
through both columns.
Note
Remote Control: The Remote Control menu shows you the primary and secondary
infrared (IR) codes to which the DHD Controller will respond. By default, both are set to
17. You can change these codes if either:
• Another device in the theater (a DVD player, for example) is responding to commands
from the DHD Controller remote control (Figure 2-5) in ways that are unpredictable or
undesirable.
• You have multiple DHD Controllers and want to control them independently, as
opposed to broadcasting commands from a single remote to all of them. In this
scenario, you can use multiple remotes programmed to use different IR codes. Or, you
can use a single remote and change the IR code as needed to address a specific
device.
Use the DHD Controller front-panel keypad to change its IR code.
Then, change the code sent by the remote to match as described
below.
Tip
Do not change the “Type” setting in this menu.
Note
When you change a remote code on the DHD Controller, you must re-program your
remote control to send that same code. To do this:
1. Using a straightened paper clip or similar object, press and hold the
CODE button on the remote control for approximately three
seconds, or until the red LED on the remote lights solid red.
2. Enter a new two-digit code between 00 and 31 inclusive. Include a
leading zero for single-digit codes; for example, enter 9 as “09.”
3. The LED turns off to confirm the code change. If you enter an invalid code, the LED
flashes for three or four seconds. Try again, entering a valid code.
Runco PlasmaWall Owner’s Operating Manual
43
Download from Www.Somanuals.com. All Manuals Search And Download.
Analog Out Mode: Select Analog Out Mode from the Service menu to change the
characteristics of the analog output signal from the DHD Controller. The choices are
RGB-- (separate sync with negative polarity), RGB++ (separate sync with positive polarity)
or RGBS (composite sync).
Display Device: The options in the Display Device menu allow you to perform certain
adjustments at the plasma display.
• Configure: Select Configure from the Display Device menu to perform the following
display device adjustments (these are global, independent of any input):
• Select Input Source from the Display Device menu to switch from one DHD
Controller output/PlasmaWall input to the other. Use the
or
button to select
RGB or DVI/HDMI, then press ENTER.
If the DVI 1 or DVI 2 DHD Controller input is active and the input
signal is HDCP-encrypted, the RGBHV output of the DHD
Controller is disabled.
Note
Use the serial command DISPLAY 4or DISPLAY 5to set the
Input Source to RGB or DVI/HDMI respectively, so that the DHD
case when you change the Input Source in the Display Device
menu.) For more information, refer to Miscellaneous Commands
Tip
• Select Inverse to invert the colors in the displayed image. Use this for repairing
burned-in areas of the plasma display.
• Select Left/Right, Up/Down, Width or Height to fine-tune the aspect ratio and
image position.
• Select Noise Filter to apply noise reduction to the displayed image.
HD Format: If the characteristics of the incoming signal on the HD1 or HD2 inputs are
known, select HD Format from the Service menu and set them as described below. Doing
so can reduce the time it takes the DHD Controller to switch from HD to 480i signals or
vice versa.
This is generally not necessary unless the DHD Controller – for whatever reason – has
difficulty determining the color space (RGB or YUV), bandwidth or resolution of the
incoming HD signal. In most situations, the Auto settings work well.
• HD/RGB 1 and HD/RGB 2 (Color Space): Select Auto, RGB or YUV.
• ADC Bandwidth: Select Auto, 75 MHz, 150 MHz or 300 MHz.
• YPbPr Input Resolution: Select Auto or specify the input resolution, if known: 480i,
480p, 576i, 576p, 720p or 1080i.
Triggers: Select Triggers from the Service menu to configure the 12-volt trigger outputs.
You can assign one or more trigger outputs to each aspect ratio. Those triggers are then
activated by selecting that aspect ratio.
To save the trigger settings so that they can be restored after a System Reset (described
below), press
repeatedly to highlight “Save.” Then, press ENTER.
44
Runco PlasmaWall Owner’s Operating Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Miscellaneous: Select Miscellaneous from the Service menu to set the following options:
• Language: Select Language from the Miscellaneous menu and press the up- or
down-arrows to select the OSD language. (Currently, only English is supported.)
• Menu Mode: This is the manner in which the OSD menus appear and disappear when
you press MENU. Choose one of the following:
0 = No transition; menus abruptly appear and disappear.
1 = Menus fade in and out.
2 = “Checkerboard” dissolve; menus appear and disappear in sections.
3 = “Window shade” effect; menus are drawn on a diagonal from top left to bottom
right, and retract in the opposite direction.
• Timeout - Short/Long: These settings control how long the OSD menus stay on
screen. Select a time-out period of from 2 to 60 seconds.
• Side Bar Color: This controls the color of the inactive image area. The range is from
-100 (black) to 100 (white).
The inactive image area is on either side of the active image area when using the
Standard 4:3 aspect ratio (or the entire screen when no incoming video signal is
present).
• Film Mode: Enable Film Mode to smooth out moving images from interlaced,
standard-definition (SD) sources. In most cases, the PlasmaWall detects the proper
“pull-down” rate and vertical frequency. However, if your source is jittery and/or tearing
you may wish to enable Film Mode to ensure stable processing for that source.
Resolution: The DHD Controller defaults to an output resolution of 720p. When using the
PlasmaWall with a computer or certain HD sources, you may want to force the DHD
Controller to use a different output resolution. If so, select Resolution from the Service
menu and choose one. Then, press ENTER to confirm.
System Reset: To reset ALL DHD Controller settings (including image settings) back to
their factory defaults, choose System Reset from the Service menu.
A confirmation message appears, reminding you to save your settings before you perform
the reset, so that you can restore them afterwards. If you have done this, select Confirm to
continue with the reset. Otherwise, click Back to cancel.
This action is not undoable. Proceed with caution! Before you
perform a System Reset, save ALL settings, including “Custom” ISF
Caution
Restore Saved Settings: Following a System Reset, select Restore Saved Settings to
apply all previously-saved settings to the PlasmaWall and DHD Controller.
Runco PlasmaWall Owner’s Operating Manual
45
Download from Www.Somanuals.com. All Manuals Search And Download.
Notes:
46
Runco PlasmaWall Owner’s Operating Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
5. Maintenance and Troubleshooting
Table 5-1 provides some general guidelines for troubleshooting problems you may
encounter with the PlasmaWall. If you encounter an issue not described here, please
contact your Runco dealer or Runco Technical Support.
5.1
Troubleshooting Tips
Table 5-1. Troubleshooting Chart
Symptom
Possible Cause(s)
Solution
The display does not turn on
after initial installation.
• The PlasmaWall is not
plugged in or the AC outlet
is not active.
• Ensure that the
PlasmaWall is plugged in
and that the AC outlet is
active.
• The DHD Controller is not
plugged in or the AC outlet
is not active.
• Ensure that the DHD
Controller is plugged in
and that the AC outlet is
active.
• The remote control
• Replace the batteries.
batteries have run out.
• The serial connection from
the DHD Controller to the
PlasmaWall is incorrect.
• Ensure that the RS-232
output from the DHD
Controller is properly
connected to the RS-232C
input on the PlasmaWall
The PlasmaWall and DHD
Controller are both on, but
there is no picture and
on-screen menus do not
appear.
• Faulty or incorrect video
connection between the
DHD Controller and the
PlasmaWall.
• Ensure that the DVI and/or
RGBHV outputs from the
DHD Controller are
properly connected to the
video inputs on the
PlasmaWall (see Figure
3-3).
• Incorrect input source
selection.
• Choose the correct input
source on the display (refer
• Display Device input
source is set to RGB, DHD
Controller input is set to
DVI 1 or DVI 2 and DVI
source is
• Set the Display Device
input source to DVI/HDMI
or use a different input on
the DHD Controller for the
encrypted source material.
HDCP-encrypted.
The display is on and menus
appear, but there is no
picture.
• Incorrect source selection.
• Source component is not
turned on.
• Select the correct source.
• Turn on the source
component.
• Source component is
connected incorrectly or
not at all.
• Check connections from
source component to DHD
Controller.
Runco PlasmaWall Owner’s Operating Manual
47
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 5-1. Troubleshooting Chart (continued)
Symptom
Possible Cause(s)
Solution
Image is too bright and/or
lacks definition in the bright
areas of the image.
• Contrast is set too high.
• Lower the contrast setting.
Image appears “washed out”
and/or dark areas appear too
bright.
• Brightness is set too high.
• Lower the brightness
setting.
Colors in the image are
swapped; for example, reds
appear blue or vice versa.
• The Red/Pr, Green/Y or
Blue/Pb outputs from the
source are connected to
the wrong inputs on the
DHD Controller.
• Ensure that the source
outputs are connected to
the correct DHD Controller
input.
• The Red, Green or Blue
(analog) outputs from the
DHD Controller are
• Ensure that the DHD
Controller outputs are
connected to the correct
inputs on the PlasmaWall.
connected to the wrong
inputs on the PlasmaWall.
RGB-HD images appear
“noisy.”
• Clock and Phase settings
need adjustment.
• Adjust Clock and Phase
settings (refer to ISF Night
“Out of range” appears
on-screen.
• The resolution and
frequency of the video
card in the computer are
not compatible with the
PlasmaWall.
• Select a compatible
resolution and vertical
frequency (refer to
Computer/Video Signal
Compatibility on
page 58).
The image is too large or too
small.
• Image size needs
adjusting.
• Adjust the image size (refer
page 39).
48
Runco PlasmaWall Owner’s Operating Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
6. Serial Communications
To interface the PlasmaWall with a home theater automation/control system or a PC
6.1
running terminal emulation software, connect it to the RS-232 output of the DHD
Controller as shown in Figure 3-4. Connect your control system or PC to the RS-232 input
RS-232 Connection
and Port Configuration
Configure the RS-232 controller or PC serial port as follows: no parity, 8 data bits, 1 stop
bit and no flow control. Set the baud rate to 19200, to match that of the DHD Controller
RS-232 port.
Serial commands to the DHD Controller take the following form:
• Commands are not case-sensitive.
6.2
Serial Command
Syntax
• For a single command that takes no parameters, type the command followed by a
carriage return; for example, to set the aspect ratio to Letterbox, type
LETTERBOX <Enter>.
• For a single command that takes a parameter, type the command, a space or a
comma and the desired value followed by a carriage return; for example, to set the
brightness to -10, type BRIGHTNESS -10 <Enter>or
BRIGHTNESS,-10 <Enter>.
• You can also send a string of multiple commands on a single line, separated by
commas. For example, COMPOSITE,BRIGHTNESS 100,ANAMORPHIC <Enter>
switches to the Composite video input, sets the brightness to 100 and sets the aspect
ratio to Anamorphic. Command strings can be up to 255 characters long.
Avoid combining the ONor POWER 1commands with other commands
Note
on a single line. After sending ONor POWER 1, allow at least 15
seconds for the DHD Controller to power up. Once it does, it will accept
and properly execute multiple serial commands.
Table 6-1 lists the RS-232 command set. The “Parameter (min/max)” column shows the
valid parameter ranges, or “NA” for commands that take no parameters.
When you enter a valid command, the DHD Controller executes it and acknowledges it
with a plus sign on the command line (+ >). When you enter an invalid command – one
that is misspelled or followed by values outside the valid range for that command – the
DHD Controller ignores it and returns a minus sign (- >).
Table 6-1. Serial Commands
Parameter
(min/max)
Value
Stored?
Command
Description
Power On/Off Commands
OFF
NA
NA
0/1
NA
NA
NA
NA
NA
Turns system off
Turns system on
ON
POWER
POWER?
Turns system on or off (toggles on/off state)
Returns power status
Runco PlasmaWall Owner’s Operating Manual
49
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 6-1. Serial Commands (continued)
Parameter
(min/max)
Value
Stored?
Command
Description
Input Selection Commands
COMPONENT
COMPOSITE
DVI1
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
YES
YES
YES
YES
YES
YES
YES
YES
NA
Selects the Component input
Selects the Composite video input
Selects the DVI 1 input
DVI2
Selects the DVI 2 input
HD1
Selects the RGB HD 1 input
Selects the RGB HD 2 input
Loops HD1 input to RGBHV output
Loops HD2 input to RGBHV output
Returns active input
HD2
HD1PASS
HD2PASS
INPUT?
SVIDEO1
SVIDEO2
YES
YES
Selects the S-Video 1 input
Selects the S-Video 2 input
Aspect Ratio Commands
ANAMORPHIC
ASPECT?
NA
NA
NA
NA
NA
NA
NA
NA
YES
NA
Selects the Anamorphic aspect ratio
Returns current aspect ratio
ASPECTIN?
ASPECTOUT?
CINEMA
NA
Returns the input source aspect ratio
Returns output screen size
NA
YES
YES
YES
YES
Selects the Cinema aspect ratio
Selects the Letterbox aspect ratio
Selects the Standard (4:3) aspect ratio
Selects the VirtualWide aspect ratio
LETTERBOX
STANDARD
VIRTUALWIDE
50
Runco PlasmaWall Owner’s Operating Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 6-1. Serial Commands (continued)
Parameter
(min/max)
Value
Stored?
Command
Description
Picture Adjust Commands
BRIGHTNESS
BRIGHTNESS?
CHROMADELAY
-100/100
NA
YES
NA
Sets a value for brightness
Returns brightness setting value
Sets a value for input color chroma delay
Returns input color chroma delay setting
Sets a value for color
-12/12
YES
NA
CHROMADELAY? NA
COLOR
-100/100
YES
NA
COLOR?
CONTRAST
CONTRAST?
FILMMODE
FILMMODE?
FILTER
NA
Returns color setting value
-100/100
NA
YES
NA
Sets a value for contrast
Returns contrast setting value
Sets Film Mode off (0) or on (1)
Returns Film Mode setting (0 = off; 1 = on)
Sets a value for input color noise filter
Returns input color noise filter setting
Adjusts phase
0/1
YES
NA
NA
0/15
NA
YES
NA
FILTER?
PHASE
0/3
YES
NA
PHASE?
NA
Returns phase setting value
Sets a value for sharpness
SHARPNESS
SHARPNESS?
TINT
-6/6
NA
YES
NA
Returns sharpness setting value
Sets a value for tint
-100/100
NA
YES
NA
TINT?
Returns tint setting value
Image Preset Commands
CUSTOM1
CUSTOM2
DAY
NA
NA
NA
NA
NA
YES
YES
YES
YES
NA
Loads “Custom 1” image preset
Loads “Custom 2” image preset
Loads “ISF Day” image preset
Loads “ISF Night” image preset
NIGHT
PRESET?
Returns currently-selected preset
(ISF Day, ISF Night, Custom 1 or Custom 2)
Runco PlasmaWall Owner’s Operating Manual
51
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 6-1. Serial Commands (continued)
Parameter
(min/max)
Value
Stored?
Command
Description
Input Position Commands
IHEIGHT
-100/100
NA
YES
NA
Sets the value for input height
IHEIGHT?
IHPOS
Returns input height value
-100/100
NA
YES
NA
Sets a value for horizontal input position
Returns input horizontal position value
Sets a value for vertical input position
Returns input vertical position value
Sets the value for input width
IHPOS?
IVPOS
-100/100
NA
YES
NA
IVPOS?
IWIDTH
-100/100
NA
YES
NA
IWIDTH?
OVERSCAN
OVERSCAN?
Returns input horizontal width value
Sets the overscan percentage
Returns overscan percentage
0/10
YES
NA
NA
Output Shift Commands
OHEIGHT
OHEIGHT?
OHPOS
-100/100
NA
YES
NA
Sets the value for output height
Returns output height value
-100/100
NA
YES
NA
Sets the value for output horizontal position
Returns output horizontal position value
Sets the value for output vertical position
Returns output vertical position value
Sets the value for output width
OHPOS?
OVPOS
-100/100
NA
YES
NA
OVPOS?
OWIDTH
OWIDTH?
-100/100
NA
YES
NA
Returns output horizontal width value
52
Runco PlasmaWall Owner’s Operating Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 6-1. Serial Commands (continued)
Parameter
(min/max)
Value
Stored?
Command
Description
Miscellaneous Commands
BKGND
-100/100
YES
Sets the background color for 4:3 aspect
ratio (-100 = black; 100 = white)
BKGND?
DATE?
NA
NA
Returns background setting value
Returns product manufacture date
NA
NA
DISPLAY
4 or 5
YES
Sets display device input source
(4 = RGB; 5 = DVI/HDMI)
DISPLAY?
NA
NA
NA
Returns display device input source value
HDINPUTRES
YES
Sets YPbPr input resolution and refresh
rate for HD1/HD2, as follows:
0 = 480i
1 = 480p
2 = 576i
3 = 576p
4 = 720p / 60 Hz
5 = 1080i / 60 Hz
6 = 720p / 50 Hz
7 = 1080i / 25 Hz
Any other value = Auto
HWVER?
INRES?
NA
NA
0/5
NA
Returns hardware version number
Returns input resolution
NA
OUTRES
YES
Sets output resolution, as follows:
0 = 480i
1 = 576i
2 = 480p
3 = 576p
4 = 720p
5 = 1080i
OUTRES?
RGBNN
NA
NA
NA
NA
Returns output resolution
Sets output color space to RGB with
negative horizontal and vertical sync
RGBPP
RGBS
NA
NA
NA
NA
Sets output color space to RGB with
positive horizontal and vertical sync
Sets output color space to RGB with
composite sync
SWVER?
TRIGGER
NA
1/3
NA
Returns software version number
YES
Assigns trigger to currently-selected aspect
ratio
Runco PlasmaWall Owner’s Operating Manual
53
Download from Www.Somanuals.com. All Manuals Search And Download.
Notes:
54
Runco PlasmaWall Owner’s Operating Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
7. Specifications
Table 7-1 lists the PlasmaWall specifications.
7.1
PlasmaWall
Specifications
Table 7-1. PlasmaWall Specifications
Native Resolution:
Screen Size (diagonal):
Active Screen Area:
Screen Aspect Ratio:
Available Aspect Ratios:
DTV Compatibility:
ISF Settings:
1365 x 768 WXGA
50 in.
43.5 x 24.5 in. (1106 x 622 mm)
16:9
Refer to Table 7-2
480i/p, 576i/p, 720p, 1080i/p
Yes
Data/Graphics Compatibility:
Inputs:
Up to 1600 x 1200
(1) Composite, (1) S-Video, (2) HD Component,
(2) HDMI 1.1 with HDCP, (1) RGB (15-pin D-sub),
(1) RS-232, (1) Wired IR (3.5-mm mini jack)
Power Requirements:
100 to 240 VAC, 50/60Hz
435W
Power Consumption (typical):
Operating Environment:
40ºF to 95ºF (5ºC to 35ºC);
20% to 80% humidity (non-condensing)
Altitude – up to 9,000 feet (2,740m)
Dimensions:
Weight (with Stand):
Regulatory Approvals:
Limited Warranty:
97.9 lbs. (44.50 kg)
Complies with FCC
Three (3) years parts and labor from the date of delivery to
the end user (except for plasma glass panel).
Plasma Glass Panel: One (1) year parts and labor from the
date of delivery to the end user.
Specifications are subject to change without notice.
Runco PlasmaWall Owner’s Operating Manual
55
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 7-2 lists the DHD Controller specifications.
7.2
DHD Controller
Specifications
Table 7-2. DHD Controller Specifications
Aspect Ratios:
Video Standards:
Output Resolution:
Inputs:
4:3, Letterbox, 16:9 Anamorphic, VirtualWide, Cinema
NTSC, PAL
480p, 576p, 720p, 840p, 960p, 1080i
(1) Composite; (2) S-Video; (1) Component; (2) HD-R (Pr), G
(Y), B (Pb), H, V; (2) DVI with HDCP
Outputs:
(1) HD-R (Pr), G (Y), B (Pb), H, V
(1) DVI-I with HDCP
Control Options:
-
-
-
Discrete infrared remote
Serial commands via RS-232
Front-panel controls
RS-232 Communication
Parameters:
19200 bps, no parity, 8 data bits, 1 stop bit, no flow control
Trigger Outputs:
(3) +12 VDC, each rated at 750 mA and thermal
fuse-protected
Bandwidth:
150 Mega Samples per Second (MSPS)
Power Requirements:
Operating Environment:
100 to 240 VAC (auto-sensing), 50/60 Hz, 160 Watts
41°F to 95°F (5°C to 35°C), 0% to 90% humidity
(non-condensing)
Dimensions:
Width = 17.50 inches (444.5 mm)
Depth = 11.19 inches (284.1 mm)
Height = 3.75 inches (95.3 mm)
Weight:
13.0 lbs. (5.90 kg)
Regulatory Approvals:
Limited Warranty:
Complies with FCC, CE C-Tick
Two (2) years parts and labor from the date of delivery to
the end user.
Specifications are subject to change without notice.
56
Runco PlasmaWall Owner’s Operating Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 7-1 shows the PlasmaWall dimensions (all dimensions are in inches).
7.3
PlasmaWall
Dimensions
0
14.801
34.252
Figure 7-1. PlasmaWall Model PL-50XA Dimensions (with Optional Table Stand)
Runco PlasmaWall Owner’s Operating Manual
57
Download from Www.Somanuals.com. All Manuals Search And Download.
The PlasmaWall can display video signals from a variety of computer sources via its
PC/RGB and DVI inputs.
7.4
Computer/VideoSignal
Compatibility
Table 7-3 lists the signal types that are compatible with the PlasmaWall, and indicates
which of those are VESA standards.
Table 7-3. Computer/Video Signal Compatibility Chart
Sync Polarity
Horiz. Vert.
neg neg
neg neg
Sync on Green
Mode
Vertical
Horizontal
Signal Type
(Dots x Lines) Frequency (Hz) Frequency (kHz)
IBM
IBM
640x400
640x480
70.10
59.90
66.70
72.80
75.00
85.00
100.40
120.40
70.10
85.10
56.25
60.30
72.20
75.00
85.10
99.80
120.00
74.60
60.00
60.00
60.00
60.00
70.10
74.90
75.00
85.00
100.00
56.20
60.00
60.00
31.50
31.50
35.00
37.90
37.50
43.30
51.10
61.30
31.50
37.90
35.20
37.90
48.10
46.90
53.70
63.00
75.70
49.70
31.00
31.70
48.40
49.70
56.50
60.20
60.00
68.70
80.50
45.10
63.90
64.00
MAC
VESA
VESA
VESA
IBM
neg
neg
neg
neg
neg
neg
neg
pos
pos
pos
pos
pos
pos
pos
neg
neg
neg
neg
neg
neg
pos
pos
pos
pos
pos
pos
pos
pos
IBM
IBM
720x400
800x600
VESA
VESA
VESA
VESA
VESA
VESA
IBM
IBM
MAC
IBM
832x624
848x480
852x480
Sync on Green
pos
neg
neg
--
pos
neg
neg
--
IBM
VESA
SGI
VESA
MAC
VESA
VESA
IBM
neg
neg
1024x768
Sync on Green
pos
pos
neg
pos
--
pos
pos
neg
pos
--
IBM
1280x768
1280x1024
1280x1024
SGI
IBM
pos
pos
Notes:
1. The PlasmaWall may not be able to display images from notebook computers in simultaneous
(CRT/LCD) mode. Should this occur, switch the notebook computer to “CRT only” mode. If you
are unsure how to do this, refer to your notebook computer’s user manual.
2. When the aspect ratio is set to Anamorphic, all modes other than 1365x768 are scaled up or
down to 1365x768. When the aspect ratio is set to Standard 4:3, all modes other than
1024x768 are scaled up or down to 1024x768.
58
Runco PlasmaWall Owner’s Operating Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 7-3. Computer/Video Signal Compatibility Chart (continued)
Sync Polarity
Horiz. Vert.
-- --
pos pos
Composite sync
Mode
Vertical
Horizontal
Signal Type
(Dots x Lines) Frequency (Hz) Frequency (kHz)
HP
IBM
1280x1024
1280x1024
1280x1024
1280x1024
1280x1024
1360x768
72.00
75.00
76.10
85.00
100.10
60.00
60.00
75.00
85.00
81.10
80.00
81.10
91.10
108.50
47.70
65.30
82.30
93.90
SUN
IBM
pos
pos
pos
neg
neg
neg
pos
pos
pos
pos
pos
pos
IBM
IBM
IBM
1400x1050
1400x1050
1400x1050
IBM
IBM
Notes:
1. The PlasmaWall may not be able to display images from notebook computers in simultaneous
(CRT/LCD) mode. Should this occur, switch the notebook computer to “CRT only” mode. If you
are unsure how to do this, refer to your notebook computer’s user manual.
2. When the aspect ratio is set to Anamorphic, all modes other than 1365x768 are scaled up or
down to 1365x768. When the aspect ratio is set to Standard 4:3, all modes other than
1024x768 are scaled up or down to 1024x768.
Runco PlasmaWall Owner’s Operating Manual
59
Download from Www.Somanuals.com. All Manuals Search And Download.
Notes:
60
Runco PlasmaWall Owner’s Operating Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
SERIAL NUMBER
RUMA-010950
rev 04-14-06 v3.2
Runco International • 2900 Faber Street • Union City, CA 94587 • Ph (510) 324-7777 / (800) 23RUNCO / Fax (510) 324-9300
Download from Www.Somanuals.com. All Manuals Search And Download.
|