RuggedServer™ RS401
4-Port Serial Device Server with Integrated 4-Port Managed Ethernet Switch
Features and Benefits
TM
Serial Device Server
eRSTP
.
ꢀ Fully compliant EIA/TIA RS485, RS422, RS232 serial ports
(software selectable) - DB9, RJ45, Phoenix style connectors
ꢀ.Transmit serial data over an IP network
ꢀ.Support for Modbus TCP, DNP 3, TIN serial protocols
.
ꢀ Baud rates up to 230 kbps
.
ꢀ Point-to-point and multi-point modes
.
ꢀ Convert Modbus RTU to Modbus TCP
.
ꢀ Supports multiple Modbus masters
.
ꢀ Serial IP port redirection software to support PC
applications statistics and built-in 'sniffer' for troubleshooting
Ethernet Ports
.
ꢀ Integrated Ethernet Switch – up to 4 ports
.
ꢀ High performance and throughput Ethernet switching
.
ꢀ Fully IEEE 802.3, IEEE 802.3u, IEEE 802.3x compliance
.
ꢀ Non-blocking, store and forward switching
.
ꢀ 10/100BaseTX, 10BaseFL, 100BaseFX options
The RuggedServer™ RS401 is an industrially hardened, serial
device server with an integrated, fully managed Ethernet
switch, designed to operate reliably in electrically harsh and
climatically demanding environments. Based on the popular
RuggedServer™ RS400, the RS401 includes all the same
functionality including an integrated 4 port serial server,
4 port managed Ethernet switch, and optional v.90 modem.
In addition, the RS401 features a more compact design that is
particularly suited for panel mount locations or installations
with tight space restrictions. The RS401 is an ideal device to
connect and “IP-enable” legacy serial devices or IEDs for
Ethernet network connectivity.
Remote Dial Up Access
.
ꢀ Integrated v.90 modem and PPP server
.
ꢀ Provides remote access to serial devices and Ethernet LAN
RuggedRated™ for Reliability in Harsh Environments
.
ꢀ Immunity to EMI and heavy electrical surges
ꢁ
.
Meets IEEE 1613 (electric utility substations)
Exceeds IEC 61850-3 (electric utility substations)
Exceeds IEC 61800-3 (variable speed drive systems)
Exceeds IEC 61000-6-2 (generic industrial)
ꢁ
.
ꢁ
.
ꢁ
.
ꢁ
.
Exceeds NEMA TS-2 (traffic control equipment)
.
ꢀ Fully independent 2kV (RMS) isolated serial ports
The RS401 provides a high level of immunity to
.
ꢀ -40°C to +85°C operating temperature (no fans)
electromagnetic interference and heavy electrical surges typical
of environments found in electric utility substations, factory
floors or in curb side traffic control cabinets. The RS401 meets
or exceeds a wide range of industry standards including
IEC61850, IEEE1613, IEC61000-6-2, IEC61800-3, and NEMA
TS-2. The RS401 also features a wide operating temperature
range of -40°C to +85°C allowing it to be installed in virtually
any location.
.
ꢀ 18 AWG galvanized steel enclosure
Universal Power Supply Options
.
ꢀ Fully integrated power supplies (no external adaptors)
.
ꢀ Popular low voltage ranges: 24VDC(9-36VDC),
48VDC (36-59VDC)
.
ꢀ Universal high-voltage range: 88-300VDC or 85-264VAC
.
ꢀ CSA/UL 60950 safety approved to +85°C
The RS401 also includes an industrially rated integrated power
supply that can support a wide range of power supply options
suitable for multiple industries and for worldwide operability.
Options include 24VDC, 48VDC, and 88VDC - 300VDC/85VAC
- 264VAC, allowing for great installation flexibility.
Rugged Operating System (ROS™) Features
ꢀ Simple plug and play operation - automatic learning,
.
negotiation, and crossover detection
.
ꢀ Integrated Cyber Security features
.
ꢀ Fast network fault recovery (<5ms) with eRSTP™
ꢀ Quality of Service (802.1p) for real-time traffic
ꢀ VLAN (802.1q) and GVRP support
ꢀ Port Rate Limiting and Broadcast Storm Limiting
ꢀ Port configuration, status, statistics, mirroring, security
.
The embedded Rugged Operating System (ROS™) within the
RS401 provides advanced layer 2 and layer 3 networking
functions, advanced cyber security features, and a full array of
intelligent functionality for high network availability and
manageability. Coupled with the ruggedized hardware design,
the RS401 is ideal for creating mission-critical, real-time,
control applications in any harsh environment.
.
.
.
Management Tools
.
ꢀ Web-based, Telnet, CLI management interfaces
.
ꢀ SNMP v1/v2/v3
I
I
S
SRUGGEDCOM
9001:20000
9001:2 00
O
O
.
ꢀ Remote Monitoring (RMON)
The RS401 is backed by RuggedCom’s all inclusive five year
warranty and unsurpassed technical support.
.
ꢀ Rich set of diagnostics with
logging and alarms
CERTIFIED
RuggedSwitchTM RS401
1
Download from Www.Somanuals.com. All Manuals Search And Download.
RuggedServer™ RS401
4-Port Serial Device Server with Integrated 4-Port Managed Ethernet Switch
Ethernet Switch Management Features
Serial IP Encapsulation
with IEEE 802.1p that allows time critical traffic
to jump ahead to the front of the queue thus
minimizing latency and reducing jitter to allow such
demanding applications to operate correctly. ROS allows
priority classification by port, tags, MAC address, and IP
type of service (TOS). A configurable "weighted fair
queuing" algorithm controls how frames are emptied from
the queues.
Many 'legacy' devices (RTU, PLC, IED, etc.) only
support serial communications via RS232 or RS485.
ROS encapsulates the serial data within a TCP
connection allowing these devices to be reached via
an IP network. A wide range of baud rates, frame
packetization options, and diagnostics allows any serial
protocol to function. The RS401 has specific support for
the following serial protocols:
ꢀ. Raw Socket serial encapsulation
VLAN (IEEE 802.1q)
ꢀ. Modbus TCP (client and server)
Virtual local area networks (VLAN) allow the segregation
of a physical network into separate logical networks with
independent broadcast domains. A measure of security is
provided since hosts can only access other hosts on the
same VLAN and traffic storms are isolated. ROS supports
802.1q tagged Ethernet frames and VLAN trunks. Port
based classification allows legacy devices to be assigned
to the correct VLAN.
ꢀ. DNP 3
ꢀ. WIN and TIN
ꢀ. Microlok
MODBUS TCP
The Modbus protocol is ubiquitous in the industrial
control and automation world. ROS converts Modbus
RTU master/slave serial data packets to Modbus TCP
client/server packets for transmission over an IP network.
This allows communications to Modbus RTU slaves via
Ethernet and allows multiple masters to poll the same
slave device.
IGMP Snooping
ROS uses IGMP snooping (Internet Group Management
Protocol v1&v2) to intelligently forward or filter multicast
traffic streams (e.g. MPEG video) to or from hosts on the
network. This reduces the load on network trunks and
prevents packets from being received on hosts that are
not involved. ROS has a very powerful implementation
of IGMP snooping that:
Remote Dial-Up Access
A v.90 modem coupled with the PPP (Point to Point
Protocol) allows ROS to provide dial-up access via
POTS (plain old telephone system) providing connectivity
to serial devices and Ethernet LAN. PAP/CHAP
authentication provide security against
unauthorized access.
.
ꢀ Can be enabled on a per VLAN basis
.
ꢀ Detects and filters all multicast streams regardless of
whether subscribers exist
.
ꢀ Supports "router-less" operation by supporting an
"active" mode
.
Rapid Spanning Tree Protocol (IEEE 802.1w)
ꢀ Restores traffic streams immediately after an RSTP
topology change
RSTP allows the creation of fault-tolerant ring and mesh
Ethernet networks that incorporate redundant links that
are 'pruned' to prevent loops. The ROS optimized version
of RSTP yields worst-case failovers of 5ms times the
'bridge diameter' and allows rings of up to 80 switches.
For example, a ring of ten switches will have failover
times under 50ms. ROS implements both STP and RSTP
to ensure interoperability with commercial switches
unlike other proprietary 'ring' based solutions.
Ethernet Port Mirroring
ROS can be configured to duplicate all traffic on one
port to a designated mirror port. When combined with
a network analyzer, this can be a powerful
troubleshooting tool.
Ethernet Port Configuration and Status
ROS allows individual ports to be 'hard' configured for
speed, duplex, auto-negotiation, flow control and more.
This allows proper connection with devices that do
not negotiate or have unusual settings. Detailed status
of ports with alarm and SNMP trap on link problems
aid greatly in system troubleshooting.
Quality of Service (IEEE 802.1p)
Some networking applications such as real-time control
or VoIP (voice over IP) require predictable arrival times for
Ethernet frames. Switches can introduce latency in times
of heavy network traffic due to the internal queues that
buffer frames and than transmit on a first come first serve
basis. ROS supports 'Class of Service' in accordance
RuggedSwitchTM RS401
3
Download from Www.Somanuals.com. All Manuals Search And Download.
RuggedServer™ RS401
4-Port Serial Device Server with Integrated 4-Port Managed Ethernet Switch
Ethernet Switch Management Features
Ethernet Statistics and RMON
SNTP (Simple Network Time Protocol)
ROS provides continuously updating statistics per port
that provide both ingress and egress packet and byte
counters as well as detailed error figures. Also provided
is full support for the RMON statistics, history, alarms,
and event groups. RMON allows for very sophisticated
data collection, analysis and detection of traffic patterns.
SNTP automatically synchronizes the internal
clock of all ROS devices on the network. This allows for
correlation of time stamped events for troubleshooting.
Event Logging and Alarms
ROS records all significant events to a non-volatile
system log allowing forensic troubleshooting. Events
include link failure and recovery, unauthorized access,
broadcast storm detection, and self-test diagnostics
among others. Alarms provide a snapshot of recent
events that have yet to be acknowledged by the network
administrator. An extreme hardware relay is de-energized
during the presence of critical alarms allowing an
external controller to react if desired.
Loss of Link Management
Some intelligent electronic devices (IEDs) have dual fiber
optic ports with automatic failover to a backup port should
the primary fail. ROS ensures this mechanism works
reliably under all failure modes by appropriately disabling
link signals when required. ROS also flushes learned
MAC addresses to ensure the failover occurs quickly.
Ethernet Port Security
Configuration via ASCII Text File
ROS provides the ability to filter or accept traffic from
specific hosts to prevent unknown users or devices from
gaining access to the network. Unauthorized access
results in the port being shutdown for a period of time
along with SNMP trap and alarm generation.
All configuration parameters are stored in an ASCII
formatted text file that can easily be transferred via TFTP
or Xmodem. The configuration file can be saved for
backup purposes and easily manipulated by a text editor.
The text same file can be downloaded to the switch at
a later date in order to re-configure or restore a
previous configuration.
Broadcast Storm Filtering
Broadcast storms wreak havoc on a network and can
cause attached devices to malfunction. This could be
disastrous on a network with mission critical equipment.
ROS limits this by filtering broadcast frames with a
user-defined threshold.
Command Line Interface (CLI)
A command line interface can be used in conjunction
with remote shell to automate data retrieval, configuration
updates, and firmware upgrades. A powerful SQL-like
capability allows expert users the ability to selectively
retrieve or manipulate any parameters the device
has to offer.
SNMP (Simple Network Management Protocol)
SNMP provides a standardized method for network
management stations the ability to interrogate devices
from different vendors. ROS supports numerous standard
MIBs (Management Information Base) allowing for easy
integration with any network management system (NMS).
A feature of SNMP supported by ROS is the ability to
generate "traps" upon system events. A NMS can record
traps from multiple devices providing a powerful network
TM
troubleshooting tool. RuggedVue is RuggedCom’s NMS
that provides graphical visualization of the network and
is fully integrated with all RuggedCom products.
HTML Web Browser and Telnet User Interfaces
ROS provides a simple, intuitive user interface for
configuration and monitoring via a standard graphical
web browser or via Telnet. All system parameters include
detailed on-line help to make setup a breeze. ROS,
presents a common look and feel and standardized
configuration process allowing easy migration to other
RuggedCom managed products.
RuggedSwitchTM RS401
4
Download from Www.Somanuals.com. All Manuals Search And Download.
RuggedServer™ RS401
4-Port Serial Device Server with Integrated 4-Port Managed Ethernet Switch
EMI and Environmental Type Tests
IEC 61850-3 EMI TYPE TESTS
TEST
Description
Test Levels
Severity Levels
Enclosure Contact
Enclosure Air
Enclosure ports
+/- 8kV
+/- 15kV
20 V/m
4
4
x
IEC 61000-4-2
IEC 61000-4-3
ESD
Radiated RFI
Signal ports
+/- 4kV @ 2.5kHz
+/- 4kV
x
4
4
4
D.C. Power ports
A.C. Power ports
IEC 61000-4-4
Burst (Fast Transient)
+/- 4kV
3
+/- 4kV
Earth ground ports
Signal ports
D.C. Power ports
A.C. Power ports
+/- 4kV line-to-earth, +/- 2kV line-to-line
+/- 2kV line-to-earth, +/- 1kV line-to-line
+/- 4kV line-to-earth, +/- 2kV line-to-line
4
3
4
IEC 61000-4-5
IEC 61000-4-6
Surge
Signal ports
10V
10V
10V
3
3
3
D.C Power ports
A.C. Power ports
Induced (Conducted) RFI
3
10V
3
Earth ground ports
Enclosure ports
IEC 61000-4-8
IEC 61000-4-29
Magnetic Field
40 A/m continuous, 1000 A/m for 1 s
30% for 0.1s, 60% for 0.1s, 100% for 0.05s
N/A
N/A
D.C. Power ports
Voltage Dips & Interrupts
30% for 1 period, 60% for 50 periods
N/A
N/A
A.C. Power ports
2
IEC 61000-4-11
IEC 61000-4-12
100% for 5 periods, 100% for 50 periods
2.5kV common, 1kV diff. mode@1MHz
2.5kV common, 1kV diff. mode@1MHz
2.5kV common, 1kV diff. mode@1MHz
30V Continuous, 300V for 1s
30V Continuous, 300V for 1s
10%
2kVac (Fail-Safe Relay output)
2kVac
2kVac
5kV (Fail-Safe Relay output)
5kV
5kV
Signal ports
D.C. Power ports
A.C. Power ports
Signal ports
D.C. Power ports
D.C. Power ports
Signal ports
D.C. Power ports
A.C. Power ports
Signal ports
D.C. Power ports
A.C. Power ports
3
3
3
4
4
Damped Oscillatory
IEC 61000-4-16
IEC 61000-4-17
Mains Frequency Voltage
Ripple on D.C. Power Supply
3
N/A
N/A
N/A
N/A
N/A
N/A
IEC 60255-5
IEC 60255-5
Dielectric Strength
H.V. Impulse
IEEE 1613 (C37.90.x) EMI IMMUNITY TYPE TESTS
Test
Description
Test Levels
Severity Levels
Enclosure Contact
Enclosure Air
Enclosure ports
Signal ports
D.C. Power ports
A.C. Power ports
Earth ground ports3
Signal ports
D.C. Power ports
A.C. Power ports
Signal ports
+/- 8kV
+/- 15kV
35 V/m
+/- 4kV @ 2.5kHz
+/- 4kV
+/- 4kV
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
IEEE C37.90.3
IEEE C37.90.2
ESD
Radiated RFI
IEEE C37.90.1
Fast Transient
+/- 4kV
2.5kV common mode @1MHz
2.5kV common, 1kV diff. mode@1MHz
2.5kV common, 1kV diff. mode@1MHz
2kVac
2kVac
2kVac
IEEE C37.90.1
IEEE C37.90
Oscillatory
Dielectric Strength
D.C. Power ports
A.C. Power ports
Environmental Type Tests
Description
Test
IEC 60068-2-1
IEC 60068-2-2
Test Levels
-40°C, 16 Hours
+85°C, 16 Hours
Severity Levels
Cold Temperature
Dry Heat
Test Ad
Test Bd
N/A
N/A
95% (non-condensing), 55°C , 6
cycles
IEC 60068-2-30
Humidity (Damp Heat, Cyclic)
Test Db
N/A
IEC 60255-21-1
IEC 60255-21-2
Vibration
Shock
Tests Fc
Tests Ea
2g @ (10 - 150) Hz
30g @ 11mS
Class 2
Class 2
Notes:
1. Only applicable to functional earth connections separated from the safety earth connection.
2. Class 2 refers to "Measuring relays and protection equipment for which a very high security margin is required or where the vibration levels are very high,
5. ( e.g. shipboard application and for severe transportation conditions")
RuggedSwitchTM RS401
5
Download from Www.Somanuals.com. All Manuals Search And Download.
RuggedServer™ RS401
4-Port Serial Device Server with Integrated 4-Port Managed Ethernet Switch
Power Supply
Technical Specifications
.
ꢀ Power Consumption: 8W (max)
.
ꢀ 24VDC: 9-36VDC (max)
EMI Immunity and Environmental Compliance
.
ꢀ 48VDC: 36-59VDC (max)
.
ꢀ IEC 61000-6-2 Industrial (Generic)
.
ꢀ HI Voltage AC/DC: 88-300VDC, 85-264VAC (max)
.
ꢀ IEC 61800-3 Industrial (Variable Speed Drive Systems)
.
ꢀ IEC 61850-3 Electric Utility Substations
Critical Alarm Relay
.
ꢀ IEEE 1613 Electric Utility Substations
.
ꢀ Form-C failsafe contact relay: 1A@30VDC
.
ꢀ NEMA TS 2 Traffic Control Equipment
Physical
IEEE Compliance
.
ꢀ Height: 3.5" (8.9cm)
.
ꢀ 802.3-10BaseT
.
ꢀ Width: 6.76" (17.2cm)
.
ꢀ 802.3u-100BaseTX, 100BaseFX
.
ꢀ Depth: 7.42" (18.8cm)
.
ꢀ 802.3x-Flow Control
.
ꢀ Weight: 4.15lbs (1.9 Kg)
.
ꢀ 802.3d-MAC Bridges
.
ꢀ Ingress Protection: IP40 (1mm objects)
.
ꢀ 802.1d-Spanning Tree Protocol
.
ꢀ Enclosure: 18 AWG galvanized steel enclosure
.
ꢀ 802.1p-Class of Service
.
ꢀ Mounting: DIN rail or panel mounted
.
ꢀ 802.1q-VLAN Tagging
.
ꢀ 802.1w-Rapid Spanning Tree Protocol
Switch Properties
.
ꢀ Switching method: Store & Forward
IETF RFC Compliance
.
ꢀ Switching latency: 5 us (100Mbps)
.
ꢀ RFC791-IP
.
ꢀ Switching bandwidth: 1.2Gbps
.
ꢀ RFC792-ICMP
.
ꢀ MAC addresses: 2048
.
ꢀ RFC793-TCP
.
ꢀ MAC address table size: 16kbytes
.
ꢀ RFC783-TFTP
.
ꢀ Priority Queues: 4
.
ꢀ RFC826-ARP
.
ꢀ Frame buffer memory: 1-Mbit
.
ꢀ RFC768-UDP
.
ꢀ VLANs: 16
.
ꢀ RFC894-IP over Ethernet
.
ꢀ IGMP multicast groups: 256
.
ꢀ RFC854-Telnet
.
ꢀ RFC1519-CIDR
Approvals
.
ꢀ RFC1541-DHCP (client)
.
ꢀ ISO: Designed and manufactured using a ISO9001:
.
ꢀ RFC1112-IGMP v1
2000 certified quality program
.
ꢀ RFC 1661-PPP
.
ꢀ CE Marking
.
ꢀ RFC2236-IGMP v2
.
ꢀ Emissions: FCC Part 15 (Class A),
.
ꢀ RFC2030-SNTP
EN55022 (CISPR22 Class A)
.
ꢀ RFC2068-HTTP
.
ꢀ Safety: cCSAus (Compliant with CSA C22.2 No. 60950,
UL 60950, EN60950)
IETF SNMP MIBS
.
ꢀ Laser Eye Safety (FDA/CDRH): Complies with 21
.
ꢀ RFC1493-BRIDGE-MIB
CFR Chapter1, Subchapter J.
.
ꢀ RFC1907-SNMPv2-MIB
.
ꢀ RFC2012-TCP-MIB
Warranty
.
ꢀ RFC2013-UDP-MIB
.
ꢀ 5 Years-Applicable to design or manufacturing
.
ꢀ RFC2578-SNMPv2-SMI
related product defects.
.
ꢀ RFC2579-SNMPv2-TC
.
ꢀ RFC2819-RMON-MIB
Network Management
.
ꢀ RFC2863-IF-MIB
.
ꢀ Web-based graphical HTML
.
ꢀ draft-ietf-bridge-rstpmib-03-BRIDGE-MIB
.
ꢀ SNMP v1, v2c
.
ꢀ draft-ietf-bridge-bridgemib-smiv2-03-RSTP-MIB
.
ꢀ Telnet, VT100
.
ꢀ IANAifType-MIB
.
ꢀ Command Line Interface (CLI)
Fiber Optical Specifications
Parameter
Fiber Port Type
10BaseFL
100BaseFX
Mode
Connectors
Multimode
Multimode
MTRJ / ST / SC
2
1310
50 or 62.5/125
-15.7
Singlemode
LC / SC
50
1310
8 or 9/125
-2.5
ST
2
820
Typical Dist. (km)
Optical Wavelength (nm)
Cable Size Core/Cladding (um)
Tx Power (dBm)
Rx Sensitivity (dBm)
Typical Budget
20
90
50 or 62.5/125
-34.4
-15.5
-32
16.5
2.5
-39
41.5
-8.2
22
-33.5
17
-37
34.5
Longer segment lengths dependent on fiber specifications. Consult factory for further details.
RuggedSwitchTM RS401
6
Download from Www.Somanuals.com. All Manuals Search And Download.
RuggedServer™ RS401
4-Port Serial Device Server with Integrated 4-Port Managed Ethernet Switch
Mechanical Drawings
RuggedSwitchTM RS401
7
Download from Www.Somanuals.com. All Manuals Search And Download.
RuggedServer™ RS401
4-Port Serial Device Server with Integrated 4-Port Managed Ethernet Switch
Mounting Options
RuggedSwitchTM RS401
8
Download from Www.Somanuals.com. All Manuals Search And Download.
RuggedServer™ RS401
4-Port Serial Device Server with Integrated 4-Port Managed Ethernet Switch
Order Codes
RS401 -__ - __ - _____ - __ - __
PS M E1E2 SP MP
PS: Power Supply
.
ꢀ 24 = 24VDC (9-36 VDC)
.
ꢀ 48 = 48VDC (36-59 VDC)
.
ꢀ HI = 85-264VAC OR 88-300VDC
M: mounting options
.
ꢀ N = No Mounting Hardware
.
ꢀ D = Din Rail Mounting
.
ꢀ P = Panel Mounting
(1)
E1, E2: Ethernet Ports 1 & 2 Options
.
ꢀ 00 = No Ethernet ports
.
ꢀ TX = 10/100BaseTX RJ45
.
ꢀ FL = 10FL Multimode ST, 820nm, 2km
.
ꢀ MJ = 100FX Multimode MTRJ
.
ꢀ MC = 100FX Multimode SC
.
ꢀ MT = 100FX Multimode ST
.
ꢀ T2 = 100FX Singlemode ST, Standard 20km
.
ꢀ L2 = 100FX Singlemode LC, Standard 20km
.
ꢀ L5 = 100FX Singlemode LC, Intermediate Reach 50km
.
ꢀ L9 = 100FX Singlemode LC, Long Reach 90km
.
ꢀ C2 = 100FX Singlemode SC, Standard 20km
.
ꢀ C5 = 100FX Singlemode SC, Intermediate Reach 50km
.
ꢀ C9 = 100FX Singlemode SC, Long Reach 90km
SP Serial Port Options
.
ꢀ 2 = 4 x RS232 via DB9
.
ꢀ 4 = 4 x RS485 via 3 POS screw terminals.
.
ꢀ 3D = 4 x RS232/RS422/RS485 via DB9
.
ꢀ 3R = 4 x RS232/RS422/RS485 via RJ45
MP Modem Port Options
.
ꢀ Blank = No Modem
.
ꢀ M = v90 (56Kbps) Modem
ORDER CODE EXAMPLES
RS401-24-D-TXTX-2
RS401-48-P-FLFL-4
RS401-HI-P-MCC2-2
RS401-HI-N-L2L5-4-M
RuggedCom Inc.
30 Whitmore Road
Woodbridge, Ontario, Canada L4L 7Z4
Tel: (905) 856-5288 Fax: (905) 856-1995
Toll Free: (888) 264-0006
1. Ports 1 & 2 must have the same type of connector
ie. RJ45, MTRJ, ST, SC, LC
Technical Support Center: (866) 922-7975 or (954) 922-7975
© 2006 RuggedCom Inc.
RuggedServer is a trademark of RuggedCom Inc.
Ethernet is a trademark of the Xerox Corporation.
Patent Pending
All specifications in this document are subject to change without notice.
Rev 1-I
For additional information on our products and
RuggedSwitchTM RS401
9
Download from Www.Somanuals.com. All Manuals Search And Download.
|