RuggedCom Switch RS401 User Guide

RuggedServer™ RS401  
4-Port Serial Device Server with Integrated 4-Port Managed Ethernet Switch  
Features and Benefits  
TM  
Serial Device Server  
eRSTP  
.
Fully compliant EIA/TIA RS485, RS422, RS232 serial ports  
(software selectable) - DB9, RJ45, Phoenix style connectors  
.Transmit serial data over an IP network  
.Support for Modbus TCP, DNP 3, TIN serial protocols  
.
Baud rates up to 230 kbps  
.
Point-to-point and multi-point modes  
.
Convert Modbus RTU to Modbus TCP  
.
Supports multiple Modbus masters  
.
Serial IP port redirection software to support PC  
applications statistics and built-in 'sniffer' for troubleshooting  
Ethernet Ports  
.
Integrated Ethernet Switch – up to 4 ports  
.
High performance and throughput Ethernet switching  
.
Fully IEEE 802.3, IEEE 802.3u, IEEE 802.3x compliance  
.
Non-blocking, store and forward switching  
.
10/100BaseTX, 10BaseFL, 100BaseFX options  
The RuggedServer™ RS401 is an industrially hardened, serial  
device server with an integrated, fully managed Ethernet  
switch, designed to operate reliably in electrically harsh and  
climatically demanding environments. Based on the popular  
RuggedServer™ RS400, the RS401 includes all the same  
functionality including an integrated 4 port serial server,  
4 port managed Ethernet switch, and optional v.90 modem.  
In addition, the RS401 features a more compact design that is  
particularly suited for panel mount locations or installations  
with tight space restrictions. The RS401 is an ideal device to  
connect and “IP-enable” legacy serial devices or IEDs for  
Ethernet network connectivity.  
Remote Dial Up Access  
.
Integrated v.90 modem and PPP server  
.
Provides remote access to serial devices and Ethernet LAN  
RuggedRated™ for Reliability in Harsh Environments  
.
Immunity to EMI and heavy electrical surges  
.
Meets IEEE 1613 (electric utility substations)  
Exceeds IEC 61850-3 (electric utility substations)  
Exceeds IEC 61800-3 (variable speed drive systems)  
Exceeds IEC 61000-6-2 (generic industrial)  
.
.
.
.
Exceeds NEMA TS-2 (traffic control equipment)  
.
Fully independent 2kV (RMS) isolated serial ports  
The RS401 provides a high level of immunity to  
.
-40°C to +85°C operating temperature (no fans)  
electromagnetic interference and heavy electrical surges typical  
of environments found in electric utility substations, factory  
floors or in curb side traffic control cabinets. The RS401 meets  
or exceeds a wide range of industry standards including  
IEC61850, IEEE1613, IEC61000-6-2, IEC61800-3, and NEMA  
TS-2. The RS401 also features a wide operating temperature  
range of -40°C to +85°C allowing it to be installed in virtually  
any location.  
.
18 AWG galvanized steel enclosure  
Universal Power Supply Options  
.
Fully integrated power supplies (no external adaptors)  
.
Popular low voltage ranges: 24VDC(9-36VDC),  
48VDC (36-59VDC)  
.
Universal high-voltage range: 88-300VDC or 85-264VAC  
.
CSA/UL 60950 safety approved to +85°C  
The RS401 also includes an industrially rated integrated power  
supply that can support a wide range of power supply options  
suitable for multiple industries and for worldwide operability.  
Options include 24VDC, 48VDC, and 88VDC - 300VDC/85VAC  
- 264VAC, allowing for great installation flexibility.  
Rugged Operating System (ROS™) Features  
Simple plug and play operation - automatic learning,  
.
negotiation, and crossover detection  
.
Integrated Cyber Security features  
.
Fast network fault recovery (<5ms) with eRSTP™  
Quality of Service (802.1p) for real-time traffic  
VLAN (802.1q) and GVRP support  
Port Rate Limiting and Broadcast Storm Limiting  
Port configuration, status, statistics, mirroring, security  
.
The embedded Rugged Operating System (ROS™) within the  
RS401 provides advanced layer 2 and layer 3 networking  
functions, advanced cyber security features, and a full array of  
intelligent functionality for high network availability and  
manageability. Coupled with the ruggedized hardware design,  
the RS401 is ideal for creating mission-critical, real-time,  
control applications in any harsh environment.  
.
.
.
Management Tools  
.
Web-based, Telnet, CLI management interfaces  
.
SNMP v1/v2/v3  
I
I
S
SRUGGEDCOM  
9001:20000  
9001:2 00  
O
O
.
Remote Monitoring (RMON)  
The RS401 is backed by RuggedCom’s all inclusive five year  
warranty and unsurpassed technical support.  
.
Rich set of diagnostics with  
logging and alarms  
CERTIFIED  
RuggedSwitchTM RS401  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
RuggedServer™ RS401  
4-Port Serial Device Server with Integrated 4-Port Managed Ethernet Switch  
Ethernet Switch Management Features  
Serial IP Encapsulation  
with IEEE 802.1p that allows time critical traffic  
to jump ahead to the front of the queue thus  
minimizing latency and reducing jitter to allow such  
demanding applications to operate correctly. ROS allows  
priority classification by port, tags, MAC address, and IP  
type of service (TOS). A configurable "weighted fair  
queuing" algorithm controls how frames are emptied from  
the queues.  
Many 'legacy' devices (RTU, PLC, IED, etc.) only  
support serial communications via RS232 or RS485.  
ROS encapsulates the serial data within a TCP  
connection allowing these devices to be reached via  
an IP network. A wide range of baud rates, frame  
packetization options, and diagnostics allows any serial  
protocol to function. The RS401 has specific support for  
the following serial protocols:  
. Raw Socket serial encapsulation  
VLAN (IEEE 802.1q)  
. Modbus TCP (client and server)  
Virtual local area networks (VLAN) allow the segregation  
of a physical network into separate logical networks with  
independent broadcast domains. A measure of security is  
provided since hosts can only access other hosts on the  
same VLAN and traffic storms are isolated. ROS supports  
802.1q tagged Ethernet frames and VLAN trunks. Port  
based classification allows legacy devices to be assigned  
to the correct VLAN.  
. DNP 3  
. WIN and TIN  
. Microlok  
MODBUS TCP  
The Modbus protocol is ubiquitous in the industrial  
control and automation world. ROS converts Modbus  
RTU master/slave serial data packets to Modbus TCP  
client/server packets for transmission over an IP network.  
This allows communications to Modbus RTU slaves via  
Ethernet and allows multiple masters to poll the same  
slave device.  
IGMP Snooping  
ROS uses IGMP snooping (Internet Group Management  
Protocol v1&v2) to intelligently forward or filter multicast  
traffic streams (e.g. MPEG video) to or from hosts on the  
network. This reduces the load on network trunks and  
prevents packets from being received on hosts that are  
not involved. ROS has a very powerful implementation  
of IGMP snooping that:  
Remote Dial-Up Access  
A v.90 modem coupled with the PPP (Point to Point  
Protocol) allows ROS to provide dial-up access via  
POTS (plain old telephone system) providing connectivity  
to serial devices and Ethernet LAN. PAP/CHAP  
authentication provide security against  
unauthorized access.  
.
Can be enabled on a per VLAN basis  
.
Detects and filters all multicast streams regardless of  
whether subscribers exist  
.
Supports "router-less" operation by supporting an  
"active" mode  
.
Rapid Spanning Tree Protocol (IEEE 802.1w)  
Restores traffic streams immediately after an RSTP  
topology change  
RSTP allows the creation of fault-tolerant ring and mesh  
Ethernet networks that incorporate redundant links that  
are 'pruned' to prevent loops. The ROS optimized version  
of RSTP yields worst-case failovers of 5ms times the  
'bridge diameter' and allows rings of up to 80 switches.  
For example, a ring of ten switches will have failover  
times under 50ms. ROS implements both STP and RSTP  
to ensure interoperability with commercial switches  
unlike other proprietary 'ring' based solutions.  
Ethernet Port Mirroring  
ROS can be configured to duplicate all traffic on one  
port to a designated mirror port. When combined with  
a network analyzer, this can be a powerful  
troubleshooting tool.  
Ethernet Port Configuration and Status  
ROS allows individual ports to be 'hard' configured for  
speed, duplex, auto-negotiation, flow control and more.  
This allows proper connection with devices that do  
not negotiate or have unusual settings. Detailed status  
of ports with alarm and SNMP trap on link problems  
aid greatly in system troubleshooting.  
Quality of Service (IEEE 802.1p)  
Some networking applications such as real-time control  
or VoIP (voice over IP) require predictable arrival times for  
Ethernet frames. Switches can introduce latency in times  
of heavy network traffic due to the internal queues that  
buffer frames and than transmit on a first come first serve  
basis. ROS supports 'Class of Service' in accordance  
RuggedSwitchTM RS401  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
RuggedServer™ RS401  
4-Port Serial Device Server with Integrated 4-Port Managed Ethernet Switch  
Ethernet Switch Management Features  
Ethernet Statistics and RMON  
SNTP (Simple Network Time Protocol)  
ROS provides continuously updating statistics per port  
that provide both ingress and egress packet and byte  
counters as well as detailed error figures. Also provided  
is full support for the RMON statistics, history, alarms,  
and event groups. RMON allows for very sophisticated  
data collection, analysis and detection of traffic patterns.  
SNTP automatically synchronizes the internal  
clock of all ROS devices on the network. This allows for  
correlation of time stamped events for troubleshooting.  
Event Logging and Alarms  
ROS records all significant events to a non-volatile  
system log allowing forensic troubleshooting. Events  
include link failure and recovery, unauthorized access,  
broadcast storm detection, and self-test diagnostics  
among others. Alarms provide a snapshot of recent  
events that have yet to be acknowledged by the network  
administrator. An extreme hardware relay is de-energized  
during the presence of critical alarms allowing an  
external controller to react if desired.  
Loss of Link Management  
Some intelligent electronic devices (IEDs) have dual fiber  
optic ports with automatic failover to a backup port should  
the primary fail. ROS ensures this mechanism works  
reliably under all failure modes by appropriately disabling  
link signals when required. ROS also flushes learned  
MAC addresses to ensure the failover occurs quickly.  
Ethernet Port Security  
Configuration via ASCII Text File  
ROS provides the ability to filter or accept traffic from  
specific hosts to prevent unknown users or devices from  
gaining access to the network. Unauthorized access  
results in the port being shutdown for a period of time  
along with SNMP trap and alarm generation.  
All configuration parameters are stored in an ASCII  
formatted text file that can easily be transferred via TFTP  
or Xmodem. The configuration file can be saved for  
backup purposes and easily manipulated by a text editor.  
The text same file can be downloaded to the switch at  
a later date in order to re-configure or restore a  
previous configuration.  
Broadcast Storm Filtering  
Broadcast storms wreak havoc on a network and can  
cause attached devices to malfunction. This could be  
disastrous on a network with mission critical equipment.  
ROS limits this by filtering broadcast frames with a  
user-defined threshold.  
Command Line Interface (CLI)  
A command line interface can be used in conjunction  
with remote shell to automate data retrieval, configuration  
updates, and firmware upgrades. A powerful SQL-like  
capability allows expert users the ability to selectively  
retrieve or manipulate any parameters the device  
has to offer.  
SNMP (Simple Network Management Protocol)  
SNMP provides a standardized method for network  
management stations the ability to interrogate devices  
from different vendors. ROS supports numerous standard  
MIBs (Management Information Base) allowing for easy  
integration with any network management system (NMS).  
A feature of SNMP supported by ROS is the ability to  
generate "traps" upon system events. A NMS can record  
traps from multiple devices providing a powerful network  
TM  
troubleshooting tool. RuggedVue is RuggedCom’s NMS  
that provides graphical visualization of the network and  
is fully integrated with all RuggedCom products.  
HTML Web Browser and Telnet User Interfaces  
ROS provides a simple, intuitive user interface for  
configuration and monitoring via a standard graphical  
web browser or via Telnet. All system parameters include  
detailed on-line help to make setup a breeze. ROS,  
presents a common look and feel and standardized  
configuration process allowing easy migration to other  
RuggedCom managed products.  
RuggedSwitchTM RS401  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
RuggedServer™ RS401  
4-Port Serial Device Server with Integrated 4-Port Managed Ethernet Switch  
EMI and Environmental Type Tests  
IEC 61850-3 EMI TYPE TESTS  
TEST  
Description  
Test Levels  
Severity Levels  
Enclosure Contact  
Enclosure Air  
Enclosure ports  
+/- 8kV  
+/- 15kV  
20 V/m  
4
4
x
IEC 61000-4-2  
IEC 61000-4-3  
ESD  
Radiated RFI  
Signal ports  
+/- 4kV @ 2.5kHz  
+/- 4kV  
x
4
4
4
D.C. Power ports  
A.C. Power ports  
IEC 61000-4-4  
Burst (Fast Transient)  
+/- 4kV  
3
+/- 4kV  
Earth ground ports  
Signal ports  
D.C. Power ports  
A.C. Power ports  
+/- 4kV line-to-earth, +/- 2kV line-to-line  
+/- 2kV line-to-earth, +/- 1kV line-to-line  
+/- 4kV line-to-earth, +/- 2kV line-to-line  
4
3
4
IEC 61000-4-5  
IEC 61000-4-6  
Surge  
Signal ports  
10V  
10V  
10V  
3
3
3
D.C Power ports  
A.C. Power ports  
Induced (Conducted) RFI  
3
10V  
3
Earth ground ports  
Enclosure ports  
IEC 61000-4-8  
IEC 61000-4-29  
Magnetic Field  
40 A/m continuous, 1000 A/m for 1 s  
30% for 0.1s, 60% for 0.1s, 100% for 0.05s  
N/A  
N/A  
D.C. Power ports  
Voltage Dips & Interrupts  
30% for 1 period, 60% for 50 periods  
N/A  
N/A  
A.C. Power ports  
2
IEC 61000-4-11  
IEC 61000-4-12  
100% for 5 periods, 100% for 50 periods  
2.5kV common, 1kV diff. mode@1MHz  
2.5kV common, 1kV diff. mode@1MHz  
2.5kV common, 1kV diff. mode@1MHz  
30V Continuous, 300V for 1s  
30V Continuous, 300V for 1s  
10%  
2kVac (Fail-Safe Relay output)  
2kVac  
2kVac  
5kV (Fail-Safe Relay output)  
5kV  
5kV  
Signal ports  
D.C. Power ports  
A.C. Power ports  
Signal ports  
D.C. Power ports  
D.C. Power ports  
Signal ports  
D.C. Power ports  
A.C. Power ports  
Signal ports  
D.C. Power ports  
A.C. Power ports  
3
3
3
4
4
Damped Oscillatory  
IEC 61000-4-16  
IEC 61000-4-17  
Mains Frequency Voltage  
Ripple on D.C. Power Supply  
3
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
IEC 60255-5  
IEC 60255-5  
Dielectric Strength  
H.V. Impulse  
IEEE 1613 (C37.90.x) EMI IMMUNITY TYPE TESTS  
Test  
Description  
Test Levels  
Severity Levels  
Enclosure Contact  
Enclosure Air  
Enclosure ports  
Signal ports  
D.C. Power ports  
A.C. Power ports  
Earth ground ports3  
Signal ports  
D.C. Power ports  
A.C. Power ports  
Signal ports  
+/- 8kV  
+/- 15kV  
35 V/m  
+/- 4kV @ 2.5kHz  
+/- 4kV  
+/- 4kV  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
IEEE C37.90.3  
IEEE C37.90.2  
ESD  
Radiated RFI  
IEEE C37.90.1  
Fast Transient  
+/- 4kV  
2.5kV common mode @1MHz  
2.5kV common, 1kV diff. mode@1MHz  
2.5kV common, 1kV diff. mode@1MHz  
2kVac  
2kVac  
2kVac  
IEEE C37.90.1  
IEEE C37.90  
Oscillatory  
Dielectric Strength  
D.C. Power ports  
A.C. Power ports  
Environmental Type Tests  
Description  
Test  
IEC 60068-2-1  
IEC 60068-2-2  
Test Levels  
-40°C, 16 Hours  
+85°C, 16 Hours  
Severity Levels  
Cold Temperature  
Dry Heat  
Test Ad  
Test Bd  
N/A  
N/A  
95% (non-condensing), 55°C , 6  
cycles  
IEC 60068-2-30  
Humidity (Damp Heat, Cyclic)  
Test Db  
N/A  
IEC 60255-21-1  
IEC 60255-21-2  
Vibration  
Shock  
Tests Fc  
Tests Ea  
2g @ (10 - 150) Hz  
30g @ 11mS  
Class 2  
Class 2  
Notes:  
1. Only applicable to functional earth connections separated from the safety earth connection.  
2. Class 2 refers to "Measuring relays and protection equipment for which a very high security margin is required or where the vibration levels are very high,  
5. ( e.g. shipboard application and for severe transportation conditions")  
RuggedSwitchTM RS401  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
RuggedServer™ RS401  
4-Port Serial Device Server with Integrated 4-Port Managed Ethernet Switch  
Power Supply  
Technical Specifications  
.
Power Consumption: 8W (max)  
.
24VDC: 9-36VDC (max)  
EMI Immunity and Environmental Compliance  
.
48VDC: 36-59VDC (max)  
.
IEC 61000-6-2 Industrial (Generic)  
.
HI Voltage AC/DC: 88-300VDC, 85-264VAC (max)  
.
IEC 61800-3 Industrial (Variable Speed Drive Systems)  
.
IEC 61850-3 Electric Utility Substations  
Critical Alarm Relay  
.
IEEE 1613 Electric Utility Substations  
.
Form-C failsafe contact relay: 1A@30VDC  
.
NEMA TS 2 Traffic Control Equipment  
Physical  
IEEE Compliance  
.
Height: 3.5" (8.9cm)  
.
802.3-10BaseT  
.
Width: 6.76" (17.2cm)  
.
802.3u-100BaseTX, 100BaseFX  
.
Depth: 7.42" (18.8cm)  
.
802.3x-Flow Control  
.
Weight: 4.15lbs (1.9 Kg)  
.
802.3d-MAC Bridges  
.
Ingress Protection: IP40 (1mm objects)  
.
802.1d-Spanning Tree Protocol  
.
Enclosure: 18 AWG galvanized steel enclosure  
.
802.1p-Class of Service  
.
Mounting: DIN rail or panel mounted  
.
802.1q-VLAN Tagging  
.
802.1w-Rapid Spanning Tree Protocol  
Switch Properties  
.
Switching method: Store & Forward  
IETF RFC Compliance  
.
Switching latency: 5 us (100Mbps)  
.
RFC791-IP  
.
Switching bandwidth: 1.2Gbps  
.
RFC792-ICMP  
.
MAC addresses: 2048  
.
RFC793-TCP  
.
MAC address table size: 16kbytes  
.
RFC783-TFTP  
.
Priority Queues: 4  
.
RFC826-ARP  
.
Frame buffer memory: 1-Mbit  
.
RFC768-UDP  
.
VLANs: 16  
.
RFC894-IP over Ethernet  
.
IGMP multicast groups: 256  
.
RFC854-Telnet  
.
RFC1519-CIDR  
Approvals  
.
RFC1541-DHCP (client)  
.
ISO: Designed and manufactured using a ISO9001:  
.
RFC1112-IGMP v1  
2000 certified quality program  
.
RFC 1661-PPP  
.
CE Marking  
.
RFC2236-IGMP v2  
.
Emissions: FCC Part 15 (Class A),  
.
RFC2030-SNTP  
EN55022 (CISPR22 Class A)  
.
RFC2068-HTTP  
.
Safety: cCSAus (Compliant with CSA C22.2 No. 60950,  
UL 60950, EN60950)  
IETF SNMP MIBS  
.
Laser Eye Safety (FDA/CDRH): Complies with 21  
.
RFC1493-BRIDGE-MIB  
CFR Chapter1, Subchapter J.  
.
RFC1907-SNMPv2-MIB  
.
RFC2012-TCP-MIB  
Warranty  
.
RFC2013-UDP-MIB  
.
5 Years-Applicable to design or manufacturing  
.
RFC2578-SNMPv2-SMI  
related product defects.  
.
RFC2579-SNMPv2-TC  
.
RFC2819-RMON-MIB  
Network Management  
.
RFC2863-IF-MIB  
.
Web-based graphical HTML  
.
draft-ietf-bridge-rstpmib-03-BRIDGE-MIB  
.
SNMP v1, v2c  
.
draft-ietf-bridge-bridgemib-smiv2-03-RSTP-MIB  
.
Telnet, VT100  
.
IANAifType-MIB  
.
Command Line Interface (CLI)  
Fiber Optical Specifications  
Parameter  
Fiber Port Type  
10BaseFL  
100BaseFX  
Mode  
Connectors  
Multimode  
Multimode  
MTRJ / ST / SC  
2
1310  
50 or 62.5/125  
-15.7  
Singlemode  
LC / SC  
50  
1310  
8 or 9/125  
-2.5  
ST  
2
820  
Typical Dist. (km)  
Optical Wavelength (nm)  
Cable Size Core/Cladding (um)  
Tx Power (dBm)  
Rx Sensitivity (dBm)  
Typical Budget  
20  
90  
50 or 62.5/125  
-34.4  
-15.5  
-32  
16.5  
2.5  
-39  
41.5  
-8.2  
22  
-33.5  
17  
-37  
34.5  
Longer segment lengths dependent on fiber specifications. Consult factory for further details.  
RuggedSwitchTM RS401  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
RuggedServer™ RS401  
4-Port Serial Device Server with Integrated 4-Port Managed Ethernet Switch  
Mechanical Drawings  
RuggedSwitchTM RS401  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
RuggedServer™ RS401  
4-Port Serial Device Server with Integrated 4-Port Managed Ethernet Switch  
Mounting Options  
RuggedSwitchTM RS401  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
RuggedServer™ RS401  
4-Port Serial Device Server with Integrated 4-Port Managed Ethernet Switch  
Order Codes  
RS401 -__ - __ - _____ - __ - __  
PS M E1E2 SP MP  
PS: Power Supply  
.
24 = 24VDC (9-36 VDC)  
.
48 = 48VDC (36-59 VDC)  
.
HI = 85-264VAC OR 88-300VDC  
M: mounting options  
.
N = No Mounting Hardware  
.
D = Din Rail Mounting  
.
P = Panel Mounting  
(1)  
E1, E2: Ethernet Ports 1 & 2 Options  
.
00 = No Ethernet ports  
.
TX = 10/100BaseTX RJ45  
.
FL = 10FL Multimode ST, 820nm, 2km  
.
MJ = 100FX Multimode MTRJ  
.
MC = 100FX Multimode SC  
.
MT = 100FX Multimode ST  
.
T2 = 100FX Singlemode ST, Standard 20km  
.
L2 = 100FX Singlemode LC, Standard 20km  
.
L5 = 100FX Singlemode LC, Intermediate Reach 50km  
.
L9 = 100FX Singlemode LC, Long Reach 90km  
.
C2 = 100FX Singlemode SC, Standard 20km  
.
C5 = 100FX Singlemode SC, Intermediate Reach 50km  
.
C9 = 100FX Singlemode SC, Long Reach 90km  
SP Serial Port Options  
.
2 = 4 x RS232 via DB9  
.
4 = 4 x RS485 via 3 POS screw terminals.  
.
3D = 4 x RS232/RS422/RS485 via DB9  
.
3R = 4 x RS232/RS422/RS485 via RJ45  
MP Modem Port Options  
.
Blank = No Modem  
.
M = v90 (56Kbps) Modem  
ORDER CODE EXAMPLES  
RS401-24-D-TXTX-2  
RS401-48-P-FLFL-4  
RS401-HI-P-MCC2-2  
RS401-HI-N-L2L5-4-M  
RuggedCom Inc.  
30 Whitmore Road  
Woodbridge, Ontario, Canada L4L 7Z4  
Tel: (905) 856-5288 Fax: (905) 856-1995  
Toll Free: (888) 264-0006  
1. Ports 1 & 2 must have the same type of connector  
ie. RJ45, MTRJ, ST, SC, LC  
Technical Support Center: (866) 922-7975 or (954) 922-7975  
© 2006 RuggedCom Inc.  
RuggedServer is a trademark of RuggedCom Inc.  
Ethernet is a trademark of the Xerox Corporation.  
Patent Pending  
All specifications in this document are subject to change without notice.  
Rev 1-I  
For additional information on our products and  
RuggedSwitchTM RS401  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  

Radica Games Games 16019 User Guide
RCA TV Mount MAF30BKR User Guide
Ricoh Two Way Radio 21 1812 User Guide
Roberts Radio Cassette Player SRCD970 User Guide
Roland DJ Equipment S MADI User Guide
Russell Hobbs Washer Dryer RH1261TW User Guide
Samsung Home Theater System 20080303092219921 User Guide
Samsung MP3 Player DVD VR335 User Guide
Samsung MP3 Player YP T6 User Guide
Schumacher Battery Charger SI263 User Guide