RuggedServer RS416
Modular Serial Device Server with Integrated Managed
Ethernet Switch
Installation Guide
RuggedCom Inc. I 30 Whitmore Road, Woodbridge, Ontario, Canada L4L 7Z4
Tel: (905) 856-5288 I Fax: (905) 856-1995 I Toll Free: (888) 264-0006
Download from Www.Somanuals.com. All Manuals Search And Download.
Table of Contents
1
2
3
Table of Figures ...................................................................................................................... 4
Table of Tables........................................................................................................................ 4
Product Overview.................................................................................................................... 6
3.1
Functional Overview........................................................................................... 6
Feature Highlights............................................................................................... 6
Display Panel Description................................................................................... 8
3.2
3.3
4
Installation ............................................................................................................................. 10
4.1
Mounting........................................................................................................... 10
Rack Mounting.......................................................................................... 11
Panel and DIN Rail Mounting .................................................................. 12
Power Supply Wiring and Grounding............................................................... 13
AC Power Supply Wiring Examples ........................................................ 15
DC Power Supply Wiring Examples ........................................................ 16
Dual Power Supplies Wiring Examples.................................................... 17
Dielectric Strength (HIPOT) Testing................................................................ 18
Failsafe Alarm Relay Wiring............................................................................ 19
Console Port Wiring ......................................................................................... 20
Serial Ports........................................................................................................ 21
Fiber Serial Interface................................................................................. 21
RS232/RS485/RS422 via DB9 ................................................................. 22
RS232/RS485/RS422 via RJ45 ................................................................ 23
RS485 Wiring ........................................................................................... 24
Serial Port Transient Protection................................................................ 25
Ethernet Ports.................................................................................................... 26
Copper Ports.............................................................................................. 26
Fiber Optic Ports....................................................................................... 27
Ethernet Panel Description ....................................................................... 28
4.1.1
4.1.2
4.2
4.2.1
4.2.2
4.2.3
4.3
4.4
4.5
4.6
4.6.1
4.6.2
4.6.3
4.6.4
4.6.5
4.7
4.7.1
4.7.2
4.7.3
5
Technical Specifications........................................................................................................ 29
5.1
Power Supply Specifications ............................................................................ 29
Failsafe Relay Contact Ratings......................................................................... 29
Data Port Specifications.................................................................................... 30
Serial Ports................................................................................................ 30
Ethernet Ports............................................................................................ 31
Type Test Specifications................................................................................... 33
Operating Environment..................................................................................... 34
Mechanical Specifications ................................................................................ 34
5.2
5.3
5.3.1
5.3.2
5.4
5.5
5.6
6
7
Agency Approvals ................................................................................................................. 36
Warranty................................................................................................................................ 36
3
2008 RuggedCom Inc. All rights reserved
Rev104
Download from Www.Somanuals.com. All Manuals Search And Download.
1 Table of Figures
Figure 1: RS416 LED Display Panel ............................................................................................... 8
Figure 2: RS416 Series Rack mount chassis orientation options – Front and rear mount. ............ 10
Figure 3: 19” Rack Mount Adapters .............................................................................................. 11
Figure 4: Rack mount adapter mounting location.......................................................................... 11
Figure 5: RS416 Series PANEL/DIN RAIL mounting diagram with ............................................... 12
Figure 6: RS416 Series Philips Screw Terminal Block................................................................... 13
Figure 7: RS416 Series Phoenix Plug Terminal Block ................................................................... 13
Figure 8: AC Power supply wiring examples.................................................................................. 15
Figure 9: DC Power supply wiring examples................................................................................. 16
Figure 10: DC And AC power supply wiring examples.................................................................. 17
Figure 11: Dielectric Strength (HIPOT) Testing.............................................................................. 18
Figure 12: Failsafe Alarm Relay Wiring.......................................................................................... 19
Figure 13: Console port location on display board ........................................................................ 20
Figure 14: Console cable .............................................................................................................. 20
Figure 15: Fiber Serial Interface (ST Connector) ........................................................................... 21
Figure 16: DB9 Female DCE Port pin-out...................................................................................... 22
Figure 17: RJ45 Port pin-out .......................................................................................................... 23
Figure 18: Conceptual recommended RS485 wiring diagram........................................................ 24
Figure 19: RJ45 port pins configuration. ........................................................................................ 26
Figure 20: 10FL ST connector....................................................................................................... 27
Figure 21: 100FX MTRJ connector ............................................................................................... 27
Figure 22: 100FX ST connector .................................................................................................... 27
Figure 23: 100FX LC connector .................................................................................................... 27
Figure 24: 100FX SC connector.................................................................................................... 27
Figure 25: Ethernet panel LED description.................................................................................... 28
Figure 26: Mechanical Drawing...................................................................................................... 35
2 Table of Tables
Table 1: LED Display – Device status LED behavior definition ....................................................... 8
Table 2: LED Display - Port LED behavior definition....................................................................... 9
Table 3: RS416 Power terminal block connection description........................................................ 14
Table 4: RS232 over RJ45 console cable pin-out ......................................................................... 20
Table 5: DB9 Female DCE Port pin-out ......................................................................................... 22
Table 6: RJ45 Port pin-out ............................................................................................................. 23
Table 7: Power Supply Specifications............................................................................................ 29
Table 8: Failsafe Relay Contact Ratings........................................................................................ 29
Table 9: Copper Port Specification................................................................................................. 30
Table 10: Fiber Optic Port Specification......................................................................................... 30
Table 11: Ethernet Ports - Copper Specifications .......................................................................... 31
Table 12: Ethernet Ports – Fiber Optic Specifications................................................................... 31
4
2008 RuggedCom Inc. All rights reserved
Rev104
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 13: Type Test Specification - Electrical Safety ..................................................................... 33
Table 14: Type Test Specification - Electrical Environment ........................................................... 33
Table 15: Type Test Specification - Atmospheric Environment...................................................... 33
Table 16: Operating Environment .................................................................................................. 34
Table 17: Mechanical Specifications.............................................................................................. 34
Table 18: Agency Approvals .......................................................................................................... 36
5
2008 RuggedCom Inc. All rights reserved
Rev104
Download from Www.Somanuals.com. All Manuals Search And Download.
3 Product Overview
3.1 Functional Overview
The RuggedServer™ RS416 is an industrially hardened serial device server with an integrated,
fully managed, Ethernet switch, designed to operate reliably in electrically harsh and climatically
demanding environments. Featuring a modular design that can support up to 16 serial ports and up
to 4 Ethernet ports, the RS416 is able to interconnect multiple types of intelligent electronic devices
(IEDs) that have different methods of communications. Using the RS416 results in fewer
connectivity devices (which reduces overall system costs) and also extends the useful life of
existing legacy IEDs (which minimizes capital expenditure for new equipment).
The RS416 provides a high level of immunity to electromagnetic interference and heavy electrical
surges typical of environments found in electric utility substations, factory floors or in curb side
traffic control cabinets. The RS416 meets or exceeds a wide range of industry standards including
IEC 61850, IEEE 1613, IEC 61000-6-2, IEC 61800-3, and NEMA TS-2. The RS416 also features a
wide operating temperature range of -40°C to +85°C allowing it to be installed in virtually any
location.
The embedded Rugged Operating System (ROS™) within the RS416 provides advanced layer 2
and layer 3 networking functions, advanced cyber security features, and a full array of intelligent
functionality for high network availability and manageability. Coupled with the ruggedized hardware
design, the RS416 is ideal for creating mission-critical, real-time, control applications in any harsh
environment. The RS416 is also backed by RuggedCom's all inclusive five year warranty and
unsurpassed technical support.
3.2 Feature Highlights
Serial Device Server
•
•
•
•
•
•
•
•
•
•
•
Modular design allows for 4, 8, 12, or 16 serial ports
Fully compliant EIA RS422 / TIA RS485, RS422, RS232
serial ports (software selectable) - DB9 or RJ45 connectors
Transmit serial data over an IP network
Support for Modbus TCP, DNP 3, TIN serial protocols
Baud rates up to 230 kbps
Raw socket mode allows conversion of any serial protocol
Point-to-point and multi-point modes
Converts Modbus RTU to Modbus
Supports multple Modbus masters
Converts DNP3.0 to DNP over UDP/TCP
Ethernet Ports
6
2008 RuggedCom Inc. All rights reserved
Rev104
Download from Www.Somanuals.com. All Manuals Search And Download.
•
•
•
•
•
Integrated Ethernet Switch - 2 or 4 port options
(copper and/or fiber)
High performance and throughput Ethernet switching
Fully IEEE 802.3, IEEE 802.3u, IEEE 802.3x compliance
Non-blocking, store and forward switching
RuggedRated™ for Reliability in Harsh Environments
•
•
•
•
•
•
•
•
•
Immunity to EMI and heavy electrical surges
Meets IEEE 1613 (electric utility substations)
Exceeds IEC 61850-3 (electric utility substations)
Exceeds IEC 61800-3 (variable speed drive systems)
Exceeds IEC 61000-6-2 (generic industrial)
Exceeds NEMA TS-2 (traffic control equipment)
Fully independent 2 kV (RMS) isolated serial ports
-40°C to +85°C operating temperature (no fans)
18 AWG galvanized steel enclosure
Universal Power Supply Options
•
•
•
•
•
Fully integrated, dual-redundant (optional) power supplies
Universal high-voltage range: 88-300 VDC or 85-264 VAC
Popular low voltage DC ranges: 12 VDC, 24 VDC, 48 VDC
Terminal blocks for reliable maintenance free connections
CSA/UL 60950 safety approved to +85°C
Rugged Operating System (ROS™) Features
•
•
•
Simple plug and play operation - automatic learning, negotiation, and crossover detection
Integrated Cyber Security features
RSTP (802.1w) and Enhanced Rapid Spanning Tree (eRSTP™) network fault recovery
(<5ms)
•
•
•
•
•
Quality of Service (802.1p) for real-time traffic
VLAN (802.1q) with double tagging and GVRP support
IGMP Snooping for multicast filtering
Port Rate Limiting and Broadcast Storm Limiting
Port configuration, status, statistics, mirroring, security
Management Tools
•
•
•
•
Web-based, Telnet, CLI management interfaces
SNMP v1/v2/v3
Remote Monitoring (RMON)
Rich set of diagnostics with logging and alarms
7
2008 RuggedCom Inc. All rights reserved
Rev104
Download from Www.Somanuals.com. All Manuals Search And Download.
3.3 Display Panel Description
The RS416 is equipped with a versatile display panel, shown in Figure 1, which is designed to
provide quick status information for each port, as well as the entire device to allow for simple
diagnostics and troubleshooting. It features:
•
•
•
RS232 console port for ‘out of band’ console access and configuration
Power supply and Alarm status indicators
Convenient port status indicators conveying Link-Activity, Duplex, or Speed via push-
button control.
•
System reset via push-button if held for 5 seconds
Figure 1: RS416 LED Display Panel
Device status LEDs exist to provide a quick visual indicator to operators for operational status of
the unit. Table 1 defines the possible LED colours and the corresponding description.
LED
Colour
Green
Red
Red
Off
Description
Power supply operating normal
Power supply failure
Alarm exist – login to console to determine alarm code
No alarms exist
Power 1 / 2
Alarm
Table 1: LED Display – Device status LED behavior definition
8
2008 RuggedCom Inc. All rights reserved
Rev104
Download from Www.Somanuals.com. All Manuals Search And Download.
The port-based LEDs can be cycled between three display modes: Status, Duplex, and Speed.
Pushing the mode button causes the display mode to be cycled. Table 2 and Table 3 define the
possible port LED colours and the corresponding description.
Ethernet Port Status
LEDs
Serial Port Status
LEDs
Mode
Colour
Green (Solid)
Green (Blinking)
Off
Green (Solid)
Orange (Solid)
Off
Green Blinking
Green (Solid)
Orange (Solid)
Off
Link
-
Status
Duplex
Activity
No link
Full-Duplex
Half-Duplex
No link
-
10 0Mbps
10 Mbps
No link
Traffic
No Traffic
Full-Duplex
Half-Duplex
No link
> 57600 bps
19200 bps – 57600 bps
< 19200 bps
No link
Speed
Table 2: LED Display - Port LED behavior definition
9
2008 RuggedCom Inc. All rights reserved
Rev104
Download from Www.Somanuals.com. All Manuals Search And Download.
4 Installation
4.1 Mounting
The RS416 has been designed with maximum mounting and display flexibility. Customers can
order an RS416 that can be mounted in a standard 19” rack, 1” DIN Rail, or directly onto a panel.
For rack mount installations, the RS416 can be ordered with connectors on the front of the unit, or
located on the rear of the chassis to allow for all data and power cabling to be installed and
connected at the rear of the rack. See Figure 2 for rack mount orientation examples.
Figure 2: RS416 Series Rack mount chassis orientation options – Front and rear mount.
10
2008 RuggedCom Inc. All rights reserved
Rev104
Download from Www.Somanuals.com. All Manuals Search And Download.
4.1.1 Rack Mounting
The RS416 can be rack mounted using the included rack mount adapter assemblies shown in
Figure 3. Secure the one rack mount adapter to the front of each side of the chassis using the
included black PAN head Philips screws in the positions shown in Figure 4. The entire chassis can
then be mounted to a standard 19” rack. An additional two rack mount adapters are included to
optionally secure the rear of the chassis in high-vibration, or seismically active locations.
Figure 3: 19” Rack Mount Adapters
Figure 4: Rack mount adapter mounting location
NOTE: Since heat within the RS416 is channeled to the enclosure, it is recommended that 1 rack
unit of space (1.75”) be kept unpopulated and free of equipment above each RS416 product to
allow for a small amount of convectional airflow. Although forced airflow is not necessary, any
increase in airflow will result in a reduction of ambient temperature that will improve long-term
reliability of all equipment mounted within the rack space.
11
2008 RuggedCom Inc. All rights reserved
Rev104
Download from Www.Somanuals.com. All Manuals Search And Download.
4.1.2 Panel and DIN Rail Mounting
The RS416 can be ordered as a Panel/DIN mount chassis. Both options involve the use of the
panel/DIN adapters to be mounted on each side of the chassis enclosure. The adapter allows the
chassis to be mounted on the standard 1” DIN rail using the grooves in the adapter, secured using
the included Philips screw. See Figure 5 for a PANEL/DIN mount diagram.
Figure 5: RS416 Series PANEL/DIN RAIL mounting diagram with
12
2008 RuggedCom Inc. All rights reserved
Rev104
Download from Www.Somanuals.com. All Manuals Search And Download.
4.2 Power Supply Wiring and Grounding
Philips Screw Terminal with Cover
Philips Screw Terminal without Cover
Safety Cover
Terminal
Chassis Ground
Connection
Surge / Chassis
Ground Jumper
Safety Cover
Screws
Figure 6: RS416 Series Philips Screw Terminal Block
Phoenix Plug Terminal with Cover
Phoenix Plug Terminal without Cover
Safety Cover
Screws
Surge / Chassis
Ground Jumper
Safety Cover
Terminal
Chassis Ground
Connection
Figure 7: RS416 Series Phoenix Plug Terminal Block
The RS416 supports dual redundant power supplies – “Power Supply 1 (PS1)” and “Power Supply
2 (PS2)”. The connections for PS1, PS2 and the fail-safe relay are located on the terminal block as
shown in Figure 6 and Figure 7.
The RS416 can be equipped with either a Philips Screw Terminal Block or a Phoenix Plug
Terminal Block. The Philips Screw Terminal Block has Philips screws with a compression plate
allowing either bare wire connections or crimped terminal lugs. We recommend the use of #6 size
ring lugs to ensure secure, reliable connections under severe shock or vibration. Both terminal
blocks have a safety cover which must be removed via two Phillips screws before connecting any
wires. The safety cover must be re-attached after wiring to ensure personnel safety. Refer to Table
3 below for a description of each terminal as well as sections 4.2.1 through 4.2.3 for wiring
examples.
13
2008 RuggedCom Inc. All rights reserved
Rev104
Download from Www.Somanuals.com. All Manuals Search And Download.
Terminal #
Description
PS1 Live / +
Usage
PS1 Live / + is connected to the positive (+) terminal if the
power source is DC or to the (Live) terminal if the power
source is AC.
1
PS1 Surge Ground is connected to the Chassis Ground via
a jumper on the terminal block. Surge Ground is used as the
ground conductor for all surge and transient suppression
circuitry.
PS1 Neutral / - is connected to the negative (-) terminal if
the power source is DC or to the (Neutral) terminal if the
power source is AC.
Chassis Ground is connected to the Safety Ground
terminal for AC inputs or the equipment ground bus for DC
inputs. Chassis ground connects to both power supply surge
grounds via a removable jumper.
PS2 Live / + is connected to the positive (+) terminal if the
power source is DC or to the (Live) terminal if the power
source is AC.
PS2 Surge Ground is connected to the Chassis Ground via
a jumper on the terminal block. Surge Ground is used as the
ground conductor for all surge and transient suppression
circuitry.
PS2 Neutral / - is connected to the negative (-) terminal if
the power source is DC or to the (Neutral) terminal if the
power source is AC.
2
3
4
5
6
7
PS1 Surge Ground
PS1 Neutral / -
Chassis Ground
PS2 Live / +
PS2 Surge Ground
PS2 Neutral / -
8
9
Relay NO Contact
Relay Common
Normally open, failsafe relay contact.
Failsafe relay common contact.
10
Relay NC Contact
Normally closed, failsafe relay contact.
Table 3: RS416 Power terminal block connection description
14
2008 RuggedCom Inc. All rights reserved
Rev104
Download from Www.Somanuals.com. All Manuals Search And Download.
4.2.1 AC Power Supply Wiring Examples
Figure 8: AC Power supply wiring examples
NOTES:
1. 100-240VAC rated equipment: A 250VAC appropriately rated circuit breaker must be
installed within 3m of unit.
2. Equipment must be installed according to the applicable country wiring codes.
3. When equipped with two HI voltage power supplies, independent AC sources can be used
to power the product for greater redundancy. However, separate circuit breakers must be
installed and separately identified (not shown in above figure).
15
2008 RuggedCom Inc. All rights reserved
Rev104
Download from Www.Somanuals.com. All Manuals Search And Download.
4.2.2 DC Power Supply Wiring Examples
Figure 9: DC Power supply wiring examples
NOTES:
1. 88-300VDC rated equipment: A 300VDC appropriately rated circuit breaker must be
installed within 3m of unit.
2. A circuit breaker is not required for 12, 24 or 48 VDC rated power supplies.
3. Equipment must be installed according to the applicable country wiring codes.
4. When equipped with two HI voltage power supplies, independent AC sources can be
used to power the product for greater redundancy. However, separate circuit breakers
must be installed and separately identified.
5. When equipped with two DC voltage power supplies (88-300VDC rated); independent
DC sources may be used to power the product for greater redundancy. However,
separate circuit breakers must be installed and separately identified (as shown in the
above figure).
16
2008 RuggedCom Inc. All rights reserved
Rev104
Download from Www.Somanuals.com. All Manuals Search And Download.
4.2.3 Dual Power Supplies Wiring Examples
Figure 10: DC And AC power supply wiring examples
NOTES:
1. 88-300VDC rated equipment: A 300VDC appropriately rated circuit breaker must be
installed within 3m of unit.
2. 100-240VAC rated equipment: A 250VAC appropriately rated circuit breaker must be
installed within 3m of unit.
3. A circuit breaker is not required for 12, 24 or 48 VDC rated power supplies.
4. Separate circuit breakers must be installed and separately identified.
5. Equipment must be installed according to the applicable country wiring codes.
17
2008 RuggedCom Inc. All rights reserved
Rev104
Download from Www.Somanuals.com. All Manuals Search And Download.
4.3 Dielectric Strength (HIPOT) Testing
For dielectric strength (HIPOT) testing in the field, users must remove the metal jumper located on
terminal 2, 4, and 6 of the power supply terminal block. This metal jumper connects transient
suppression circuitry to chassis ground and must be removed in order to avoid damage to transient
suppression circuitry during HIPOT testing. Figure 11 shows the proper HIPOT test connections
and should be followed to avoid damage to the device.
Figure 11: Dielectric Strength (HIPOT) Testing
18
2008 RuggedCom Inc. All rights reserved
Rev104
Download from Www.Somanuals.com. All Manuals Search And Download.
4.4 Failsafe Alarm Relay Wiring
The “Failsafe” output relay is provided to signal critical error conditions that may occur on the
RS416. The contacts are energized upon power up of the unit and remain energized until a critical
error occurs. The proper relay connections are shown in Figure 12. One common application for
this output is to signal an alarm if a power failure or removal of control power occurs. The failsafe
relay current and power handling capabilities are defined in
Figure 12: Failsafe Alarm Relay Wiring
19
2008 RuggedCom Inc. All rights reserved
Rev104
Download from Www.Somanuals.com. All Manuals Search And Download.
4.5 Console Port Wiring
A RS232 console port for configuration and management of the device is located on the LED
display module shown in Figure 13. This port is intended to be a temporary connection during initial
configuration or troubleshooting and allows for direct access to the serial-based management
console. The connection is made using the DB9-Female to RJ45 console cable included in the
device packaging shown below. Console connection settings are 57600 baud, no parity bits, 8 data
bits, and 1 stop bit.
Figure 13: Console port location on display board
Figure 14: Console cable
For user reference, the console cable pin-out is show in the table below.
RuggedCom RS232 over RJ45 pin-out specification
Signal Name (PC is DTE)
DCD – Carrier detect
TxD – Transmit Data
RxD – Receive Data
DTR – Data terminal ready
Signal GND
Female DB9
Male RJ45
1
2
3
4
5
6
7
8
9
2
5
6
3
4
1*
8
7
DSR – Data set ready
RTS – Ready to send
CTS – Clear to send
RI – Ring Indicator
1*
Table 4: RS232 over RJ45 console cable pin-out
After initial configuration, the RS416 can be configured via a number of mechanisms such as
Telnet, and the built-in web server. Consult the RuggedSwitch ROS User Guide for further details.
NOTE: This port is not intended to be a permanent connection and the cable shall be less than 2m
(6.5 ft) in length.
20
2008 RuggedCom Inc. All rights reserved
Rev104
Download from Www.Somanuals.com. All Manuals Search And Download.
4.6 Serial Ports
The RS416 can be equipped with a Fiber Serial Interface, RS232/RS485/RS422 DB9 serial ports
or RS232/RS485/RS422 RJ45 serial ports.
4.6.1 Fiber Serial Interface
The RS416 can be equipped with a Fiber Serial Interface (ST connector only) which allows RS485,
RS422, or RS232 devices to communicate over secure, noise immune, optically isolated, fiber
optic cabling at extended distances as well as protocol independent conversion to multimode fiber
optics.
Figure 15: Fiber Serial Interface (ST Connector)
21
2008 RuggedCom Inc. All rights reserved
Rev104
Download from Www.Somanuals.com. All Manuals Search And Download.
4.6.2 RS232/RS485/RS422 via DB9
Each port is individually selectable via software to be RS232, RS485 or RS422. The DB9 port and
pin-out is shown below.
Figure 16: DB9 Female DCE Port pin-out
Pin
1
2
3
4
RS232 Mode
RS485 Mode
RS422 Mode
CD
TX
RX
-
-
TX/RX+
TX+
RX+
-
-
DTR
-
5
Common (Isolated Ground)
6
7
8
DSR
CTS
RTS
RI
-
RX-
TX-
TX/RX -
-
9
(No Connection)
-
-
Shield
Chassis Ground
Table 5: DB9 Female DCE Port pin-out
NOTES:
1. No internal termination is provided.
2. Pins 1, 4, and 6 are connected internally. Pins 7 and 8 are connected internally. The pins are
permanently asserted to 5V so that DTE devices that require DCD, DTR, or CTS signals will
operate. However, hardware flow control via RTS is not recognized.
3. The Common terminals are optically isolated; however, there is transient voltage protection
circuitry between the Common terminals and chassis ground.
22
2008 RuggedCom Inc. All rights reserved
Rev104
Download from Www.Somanuals.com. All Manuals Search And Download.
4.6.3 RS232/RS485/RS422 via RJ45
Each port is individually selectable via software to be RS232, RS485 or RS422. The RJ45 port and
pin-out is shown below.
Figure 17: RJ45 Port pin-out
Pin
1
2
3
RS232 Mode
DSR
RS485 Mode
RS422 Mode
-
-
-
RX-
-
-
DCD
DTR
4
Common (Isolated Ground)
5
6
7
8
RX
TX
CTS
RTS
-
TX/RX +
-
RX+
TX +
-
TX/RX -
Chassis Ground
TX -
Shield
Table 6: RJ45 Port pin-out
NOTES:
1. No internal termination is provided.
2. Pins 1, 2, and 3 are connected internally. Pins 7 and 8 are connected internally. The pins are
permanently asserted to 5V so that DTE devices that require DCD, DTR, or CTS signals will
operate. However, hardware flow control via RTS is not recognized.
3. The Common terminals are optically isolated; however, there is transient voltage protection
circuitry between the Common terminals and chassis ground.
23
2008 RuggedCom Inc. All rights reserved
Rev104
Download from Www.Somanuals.com. All Manuals Search And Download.
4.6.4 RS485 Wiring
Each RS485 port can communicate to multiple RS485 devices by daisy chaining devices over a
single twisted pair with transmit and receive signals on the same two wires (half duplex). The
following guidelines should be followed to ensure reliable continuous communication:
1. To minimize the effects of ambient electrical noise, shielded cabling is recommended.
2. The correct polarity must be observed throughout a single daisy chain.
3. The number of devices wired should not exceed 32, and total distance should be less than
4000 feet (at 100 kbps).
4. The Common terminals should be connected to the common wire inside the shield.
5. The shield should be connected to earth ground at a single point to avoid loop currents
6. The twisted pair should be terminated at each end of the chain.
The figure below shows the recommended RS485 wiring.
Figure 18: Conceptual recommended RS485 wiring diagram
24
2008 RuggedCom Inc. All rights reserved
Rev104
Download from Www.Somanuals.com. All Manuals Search And Download.
4.6.5 Serial Port Transient Protection
RuggedCom does not recommend the use of copper cabling of any length for critical real-time
substation automation applications. However, transient suppression circuitry is present on all
copper ports to protect against damage from electrical transients and to ensure IEC 61850-3 and
IEEE 1613 Class 1 conformance. This means that during the transient event communications
errors or interruptions may occur but recovery is automatic.
RuggedCom also does not recommended to use these ports to interface to field devices across
distances which could produce high levels of ground potential rise, (i.e. greater than 2500V) during
line to ground fault conditions.
25
2008 RuggedCom Inc. All rights reserved
Rev104
Download from Www.Somanuals.com. All Manuals Search And Download.
4.7 Ethernet Ports
4.7.1 Copper Ports
The RS416 may have up to 4 10/100BaseTX ports that allow connection to standard CAT-5 UTP
cable with RJ45 male connectors. All RJ45 Ethernet ports feature auto-negotiating, auto-polarity,
and auto-crossover functions. The RJ45 receptacles can also accept and take advantage of
screened (commonly known as “shielded”) cabling. Figure 19 shows the RJ45 port pins
configuration.
Pin
1
Signal
+Rx
-Rx
2
3
+Tx
4
No Connection
No Connection
-Tx
5
6
7
No Connection
No Connection
8
Figure 19: RJ45 port pins configuration.
NOTE: RuggedCom does not recommend the use of copper cabling of any length for critical real-
time substation automation applications. However, transient suppression circuitry is present on all
copper ports to protect against damage from electrical transients and to ensure IEC 61850-3 and
IEEE 1613 Class 1 conformance. This means that during the transient event communications
errors or interruptions may occur but recovery is automatic. RuggedCom also does not
recommended to use these ports to interface to field devices across distances which could produce
high levels of ground potential rise, (i.e. greater than 2500V) during line to ground fault conditions.
26
2008 RuggedCom Inc. All rights reserved
Rev104
Download from Www.Somanuals.com. All Manuals Search And Download.
4.7.2 Fiber Optic Ports
Depending on the order code of the product, the RS416 can be equipped with several different
types of fiber optic ports. The Transmit (TX) and Receive (RX) connections of each port must be
properly connected and matched for proper link and operation. Modules populated on the top row
of the device typically have locking mechanisms or tabs towards the top of the unit. Modules
located on the bottom row of the device have locking mechanisms or tabs towards the bottom of
the device.
The drawings in the following figures show each fiber optical connector style with a side and top
view to allow the user to identify the proper cable connection orientation. If modules are populated
on the bottom row of the device, the transceiver orientation will be reversed (i.e. RX and TX will be
reversed).
Figure 21: 100FX MTRJ connector
Figure 22: 100FX ST connector
Figure 20: 10FL ST connector
Figure 24: 100FX SC connector
Figure 23: 100FX LC connector
27
2008 RuggedCom Inc. All rights reserved
Rev104
Download from Www.Somanuals.com. All Manuals Search And Download.
4.7.3 Ethernet Panel Description
Each Ethernet module is equipped with two LEDs that indicate link/activity status information. The
LED will be solid for ports with link, and will blink for activity. The diagram in Figure 25 highlights
the port and the associated link/activity LED.
Figure 25: Ethernet panel LED description
28
2008 RuggedCom Inc. All rights reserved
Rev104
Download from Www.Somanuals.com. All Manuals Search And Download.
5 Technical Specifications
5.1 Power Supply Specifications
Power Supply
Type
Input Range
Fuse
Rating
Max. Power Consumption3
Min
Max
12 – 24 VDC
24 VDC
10 VDC
18 VDC
36 VDC
36 VDC
36 VDC
59 VDC
6.3A(F) 2
5A(F) 2
2A(T) 2
15 W
48 VDC
HI (125/250 VDC) 1 88 VDC 300 VDC
HI (110/230 VAC) 1 85 VAC 265 VAC
Table 7: Power Supply Specifications
2A(T) 1,2
NOTES:
1. This is the same power supply for both AC and DC.
2. (F) Denotes fast-acting fuse, (T) denotes time-delay fuse
3. Power consumption varies based on configuration. 10/100Tx ports consume roughly 1W
less than fiber optic ports
4. For continued protection against risk of fire, replace only with same type and rating of fuse.
5.2 Failsafe Relay Contact Ratings
Parameter
Value (Resistive Load)
Max Switching Voltage
240VAC, 125VDC
Rated Switching Current 2A @ 240VAC
0.15A @ 125VDC, 2A @ 30VDC
Max Switching Capacity 150W, 500VA
Table 8: Failsafe Relay Contact Ratings
29
2008 RuggedCom Inc. All rights reserved
Rev104
Download from Www.Somanuals.com. All Manuals Search And Download.
5.3 Data Port Specifications
5.3.1 Serial Ports
5.3.1.1 Copper Ports
Parameter
Specifications
Notes
Baud Rate
Connector
Isolation
300 bps – 230 kbps
DB9 or RJ45
2.5 kV
RMS 1-minute
Table 9: Copper Port Specification
5.3.1.2 Fiber Optic Ports
Parameter
Specifications
Mode
Multimode
Connector
ST
5
Typical Dist. (km)
Optical Wavelength (nm)
820
Cable Size
50/125
Core/Cladding (um)
62.5/125
Table 10: Fiber Optic Port Specification
NOTES:
1. Maximum segment length is greatly dependent on factors such as fiber quality, and
number of patches and splices. Please consult RuggedCom sales associates when
determining maximum segment distances.
30
2008 RuggedCom Inc. All rights reserved
Rev104
Download from Www.Somanuals.com. All Manuals Search And Download.
5.3.2 Ethernet Ports
5.3.2.1 Copper Ports
Parameter
Specification
Notes
Speed
Duplex
10/100 Mbps
FDX / HDX
> Category 5
TIA/EIA T568A/B
100 m
Auto-negotiating
Auto-negotiating
Shielded/Unshielded
Auto-Crossover, Auto-polarity
Cable-Type
Wiring Standard
Max Distance
Connector
Isolation
RJ45
1.5 kV
RMS 1-minute
Table 11: Ethernet Ports - Copper Specifications
5.3.2.2 Fiber Optic Ports
The following sections detail fiber optic specifications on ports that can be ordered with the RS416.
The user determines the type of optics at time of ordering and can determine the modules installed
on a particular unit by reading the factory data file via the ROSTM user interface. The following
section provides detailed specifications of fiber optic modules.
The dual-port fast Ethernet optical specifications for slots 5 and 6 are shown in Table 12 organized
by module order code. Module order codes are contained within each product’s factory data when
assembled and configured at the factory. Consult ROSTM to determine the optical assemblies
installed in a particular product.
Cable
Type2
Tx Pwr
(dBm) 3
(Min/Max)
Rx
Rx
Typical
Power
Optics
Order Code
Mode /
Connector
Tx
(nm)
λ
Sensitivity Saturation Distance Budget
(dBm) 3
(dBm) 3
(km) 1
(dB)
(
µm)
12-11-0011
12-11-0012
12-11-0007
12-11-0009
12-11-0008
12-11-0046
12-11-0006
12-11-0005
12-11-0004
12-11-0031
12-11-0032
12-11-0033
12-11-0034
MM / ST
SM / ST
MM / ST
MM / SC
MM / MTRJ
MM / LC
SM / ST
SM / SC
SM / LC
SM / SC
SM / LC
SM / SC
SM / LC
850
1310
50/125
9/125
-16.5/-10.6
-27 / -14
-34
-35
-11.2
-3
2
5
21
8
1310
1310
1310
50/125
50/125
9/125
-15.7
-19 / -14
-15/-8
-33.5
-32
-11
-14
-7
2
2
17
15
-32
20
16.5
1310
1310
9/125
9/125
-5 / 0
0 / 5
-35
-37
-3
0
50
90
32.5
39.5
Table 12: Ethernet Ports – Fiber Optic Specifications
31
2008 RuggedCom Inc. All rights reserved
Rev104
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTES:
1. Maximum segment length is greatly dependent on factors such as fiber quality, and
number of patches and splices. Please consult RuggedCom sales associates when
determining maximum segment distances.
2. All optical power numbers are listed as dBm averages.
3. All cabling is duplex type unless otherwise specified.
4. These transceivers utilize a distributed feedback (DFB) type laser and are rated for -20°C
to +85°C operation only.
32
2008 RuggedCom Inc. All rights reserved
Rev104
Download from Www.Somanuals.com. All Manuals Search And Download.
5.4 Type Test Specifications
Electrical Safety
Levels
Comments
ANSI/IEEE C37.90 (1989)
IEC 60255-5 (Section 6)
IEC 60255-5 (Section 8)
IEC 60255-5 (Section 6
Dielectric Withstand
2 kV rms for 1 minute
High Voltage Impulse
Insulation Resistance
5 kV peak
500 VDC for 1 minute
Table 13: Type Test Specification - Electrical Safety
Electrical Environment
High Frequency Disturbance
(Oscillatory)
Levels
Comments
ANSI/IEEE C37.90.1
IEC 60255-22-1
IEC 61000-4-5
(Level 4)
2.5 kV @ 1MHz for 2s
IEC Surge
4 kV / 2 kV
2 kV / 1 kV
IEC 61000-4-4
(Level 4)
IEC Fast Transient
ANSI/IEEE Fast Transient
IEC Radiated RFI Immunity
ANSI/IEEE Radiated RFI
Immunity
4 kV
10 V/m
ANSI/IEEE C37.90.1
IEC 61000-4-3
35 V/m
ANSI/IEEE C37.90.2
ESD
15 kV (air discharge)
8 kV (contact)
IEC 61000-4-2
(Level 4)
(Electrostatic Discharge)
Table 14: Type Test Specification - Electrical Environment
Atmospheric Environment
Levels
Comments
IEC 60068-2-1
Test Ad: 16 hrs @ -40°C
IEC 60068-2-2
Temperature (Dry Cold)
-40°C
Temperature (Dry Heat)
Humidity
85°C
Test Bd: 16 hrs @ 85°C
IEC 60068-2-30
Test Db: 6 cycles, 55°C, 95% Humidity
95%
non-condensing
Table 15: Type Test Specification - Atmospheric Environment
33
2008 RuggedCom Inc. All rights reserved
Rev104
Download from Www.Somanuals.com. All Manuals Search And Download.
5.5 Operating Environment
Parameter
Range
Comments
Ambient Temperature as
measured from a 30cm
radius surrounding the
center of the RS1600
enclosure.
Ambient Operating
Temperature
-40 to 85°C
Ambient Relative Humidity
Ambient Storage
5% to 95%
Non-condensing
-40 to 85°C
Temperature
Table 16: Operating Environment
5.6 Mechanical Specifications
Parameter
Value
Comments
(Length x Width x Height)
with mounting brackets
installed
18.29 x 10.17 x 1.74 inches
(464,57) x (258,32) x (44,20) mm
Dimensions
Weight
10 lb (4.5 Kg)
Enclosure
18 AWG galvanized steel
Table 17: Mechanical Specifications
34
2008 RuggedCom Inc. All rights reserved
Rev104
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 26: Mechanical Drawing
35
2008 RuggedCom Inc. All rights reserved
Rev104
Download from Www.Somanuals.com. All Manuals Search And Download.
6 Agency Approvals
Agency
CSA
CE
FCC
CISPR
FDA/CDRH
IEC/EN
Standards
CSA C22.2 No. 60950, UL 60950
Comments
Approved
Approved
Approved
Approved
Compliant
Compliant
EN 60950, EN 61000-6-2
FCC Part 15, Class A
EN55022, Class A
21 CFR Chapter 1, Subchapter J
EN60825-1:1994 + A11:1996 + A2:2001
Table 18: Agency Approvals
7 Warranty
RuggedCom warrants this product for a period of five (5) years from date of purchase. For
Should this product require warranty or service contact the factory at:
RuggedCom Inc.
30 Whitmore Road,
Woodbridge, Ontario
Canada L4L 7Z4
Phone: (905) 856-5288
Fax: (905) 856-1995
36
2008 RuggedCom Inc. All rights reserved
Rev104