Rosewill Network Card RC217 User Guide

SATA II 4 Port PCI RAID Card RC217  
User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SATAII 4 port PCI RAID Card RC217  
User Manual  
Q5: What is Raid1?  
A5: RAID1 also known as Mirroring or SAFE. Mirroring creates an identical twin for a selected disk by having the data  
simultaneously written to two disks. If a read failure occurs on one drive, the system will read the data from the other  
drive. Raid1 need two drives to store the same data.  
Q6: What is Raid10?  
A6: RAID10 also known as RAID 0+1 or Mirrored-Striping or “SAFE and FAST”. RAID10 combine both Striping and  
Mirroring technologies to provide both the performance enhancements that come from Striping and the data availability  
and integrity that comes from Mirroring. There are at least four hard drives is need for RAID10 setting.  
Q7: What is RAID5?  
A7: RAID5 also known as Distributed Parity RAID. RAID 5 adds fault tolerance to Disk Striping by including parity  
information with the data. The data and parity information is arranged on the disk array so that parity is written to  
different disks. There are at least three hard drives is need for RAID5 setting.  
Q8: What is JBOD?  
A8: The JBOD (Just a Bunch of Disks , also known as Contiguous) means a single logical drive that can either be an entire  
disk drive or a segment of a disk drive. JBOD is the Contiguous configuration option when creating RAID Groups (or sets)  
in the SATARAID5 Manager utility.  
Q9: What is CONCATENATED?  
A9: Concatenated also known as Big Drive, The Concatenated combines multiple disks or multiple segments of disks  
into a single large disk. It does not provide any data protection or performance improvement but can be useful for utilizing  
leftover space on all disks.  
Q10: How to make sure RAID5 setting is ready for working?  
A10: RAID5 setting may cost hours for component ready and function available, please be patient for that. Especially if Raid5  
setting by BIOS, please Click “Task Manager” to make sure there is “Green” color on the selected components and then  
Raid5 setting is completed.  
Q11: May use the existing used hard drive to RAID5 Card?  
A11: Yes, it is workable. But, the working data on your existing used HDD may NOT work and be treated as a blank  
drive when you migrate it to RAID5 Card environment.  
Q12: Why Windows Device Manager can NOT detect my hard drives, but BIOS can detect it?  
A12: In RAID storage system, RAID managing information is saved on the drive. If without the correct RAID  
Creating by BIOS or GUI, Windows Device Manager can NOT recognize the existing of hard drive.  
Q13: Why RAID5 GUI can NOT recognize my migrating used drive?  
A13: When migrating the used HDD to RAID5 card, we better to perform the "Delete Raid Set" on BIOS setting, since the  
used HDD may have some different format of RAID managing information and RAID5 GUI may be confused by this data  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
SATAII 4 port PCI RAID Card RC217  
User Manual  
and no recognition.  
Q14: Why Rebuilding take so long time?  
A14: The “Rebuilding” function on Raid 1 or Raid10 always spend long hours for component ready, data copying and  
function available, especially for high volume data. Please be patient for the rebuilding ready.  
Q15: How to create the RAID setting on RAID5 Card?  
A15: If 32bit PCI or 64bit PCI-X or PCI-Express RAID5 Host card, RAID5 sets can be created and managed by either the  
BIOS utility setting or SATARAID5 GUI setting under Windows. Only SATARAID5 GUI is functional, as CardBus adapter or  
ExpressCard/34 Adapter for Notebook.  
A16: How to get the PDF file of complete RAID5 manual for RAID5 Host Adapter?  
Q16: Please find the SATARAID5-UserGuide_v1.40.pdf under the GUI folder of Driver CD on your card package.  
Q17: OK to use multiple RAID5 Cards in one server system?  
A17: Yes, it works, even mixed with different product model of RAID5 card in one server system. RAID5 GUI can manage  
each RAID5 card individually but NO cross Raid5 setting is provided.  
Q18: Can we add RAID5 Cards to one PC system, which has RAID card (No RAID5, only RAID0 or RAID1) already?  
A18: No, only one RAID GUI or RAID5 GUI can exist in PC system, so we don’t recommend to use the mixed RAID and  
RAID5 cards in one system. If you decide to sacrifice the RAID GUI and use the RAID5 GUI only in system, you must  
remove the existing RAID GUI from your PC system first before RAID5 Card hardware installation, otherwise the system  
will hang up. After RAID5 card, RAID5 driver and RAID5 GUI be successfully installed, RAID5 GUI can manage the  
activities of RAID5 card only, no RAID card activity.  
Q19: Whether I can plug a 64bit PCI-X SATA II –3Gbps RAID5 card into a motherboard 32bit PCI slot and test it?  
A19: Yes, it works.  
Q20: Can I connect DVD-ROM optical drive to RAID5 card?  
A20: Yes, it works, but RAID5 card supports one optical drive only. RAID5 BIOS and Windows Device Manager can  
recognize the optical drive automatically, but RAID5 GUI does NOT. If your SATA Optical Drive no detection, please ask  
DVD maker for firmware updating.  
Q21: OK to install Windows OS on RAID5 Drives?  
A21: RAID5 card is software RAID5, which is managed and manipulated by Software Driver. It’s NOT good to let Driver  
layer charge the tasks of OS layer, so we don’t recommend to use the RAID5, RAID0, RAID1, RAID10 as OS Disks. Please  
create the RAID setting and use the RAID features on Data Disks only.  
Q22: How to get Linux drivers?  
A22: Please visit http://www.siliconimage.com/support/index.aspx?pid=0&cid=0& find Linux drivers on the folder of  
/Linux at package Driver CD.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
SATAII 4 port PCI RAID Card RC217  
User Manual  
Q23: After Raid5 card installation, Windows can’t restart and hang during booting, unless CD Shutoff.  
A23: It sounds the issue on Mother board BIOS, Please contact Mother board maker to have the latest BIOS update.  
You may also contact agent and try to update the BIOS of Raid5 card.  
1. Introduction  
This RAID5 Host Adapter provides a 64bit / 133 MHz PCI-x (or 32bit / 66Mhz PCI or 4GB/s PCI-e 8X) bus interface on  
the host side and four, fully compliant Serial ATA II – 3Gbps ports on the device side to access SATA Hard disk and  
optical drive.  
The board can be used to upgrade your desktop computer to have 4Ports Serial ATA Channels and support RAID 5, RAID  
0+1, RAID 0, RAID 1 and JBOD features.  
The board supports Serial ATA Generation 1 & Generation 2 transfer rate of 1.5 Gbps / 3Gbps. It comes completely with  
drivers for Windows Vista, 2000, XP, 2003.  
1.1. Features  
1.1.1. PCI Interface (optional)  
 Compliant with PCI Specification revision 2.2  
 Integrated PCI DMA engines.  
 32bit / 66MHz fully compliant PCI host interface.  
1.1.2. PCI-X Interface (optional)  
  Compliant with PCI-X Specification, revision 1.0a  
  Supports 133 MHz PCI-X with 64-bit data  
1.1.3. PCI-e Interface (optional)  
  x8 PCI Express Bus  
  PCI Express Specification, Revision 1.0a  
  Maximum realized bandwidth on PCI Express interface is 2 GB/s in each direction simultaneously,  
for an aggregate of 4 GB/s  
1.1.4. High Speed Serial ATA Interface  
 Four high speed Serial ATA interface ports, each supporting 1st generation & 2nd generation Serial ATA  
data rates 1.5Gbps/ 3Gbps.  
  Provides RAID 0 (Stripping) to greatly increase the performance of data transfer by simultaneously writing  
data to 2 drives.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
SATAII 4 port PCI RAID Card RC217  
User Manual  
  Provides RAID 1 (Mirroring) to protect the data from a disk failure by writing identical data on 2 drives.  
  RAID 0+1 (Mirrored-Stripping) combine both Striping and Mirroring technologies to provide both the performance  
enhancements that come from Striping and the data availability and integrity that comes from Mirroring.  
  RAID 5 (Distributed Parity RAID) has Highest Read data transaction rate and Good aggregate transfer rate  
  JBOD is a virtual disk that combines all disk drives as one entire disk drive  
 Fully compliant with Serial ATA specifications  
 Supports Spread Spectrum in receiver.  
1.2. Package Contents  
  RAID5 SATA II 4Ports Host Adapter  
  Users Manual  
  Driver CD  
2. What Is RAID  
RAID - Redundant Array of Independent Disks  
RAID technology manages multiple disk drives to enhance I/O performance and provide redundancy in order to withstand  
the failure of any individual member, without loss of data.  
Disk Striping (RAID 0)  
Striping is a performance-oriented, non-redundant data mapping technique. While Striping is discussed as a RAID Set  
type, it is actually does not provide fault tolerance. With modern SATA bus mastering technology, multiple I/O operations  
can be done in parallel, enhancing performance. Striping arrays use multiple disks to form a larger virtual disk.  
Disk Mirroring (RAID 1)  
Disk mirroring creates an identical twin for a selected disk by having the data simultaneously written to two disks. This  
redundancy provides instantaneous protection from a single disk failure. If a read failure occurs on one drive, the system  
reads the data from the other drive.  
Mirrored-Striping (RAID 0+1 also known as RAID 10)  
A Mirrored-Striping Set does just what it says, combining both Striping and Mirroring technologies to provide both the  
performance enhancements that come from Striping and the data availability and integrity that comes from Mirroring.  
When data is written to a Mirrored-Striped Set, instead of creating just one virtual disk as Striping would do, a second,  
Mirrored virtual disk is created as well.  
Parity RAID (RAID 5)  
Parity or RAID 5 adds fault tolerance to Disk Striping by including parity information with the data. Parity RAID dedicates  
the equivalent of one disk for storing parity stripes. The data and parity information is arranged on the disk array so that  
parity is written to different disks. There are at least 3 members to a Parity RAID set. The following example illustrates how  
the parity is rotated from disk to disk.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
SATAII 4 port PCI RAID Card RC217  
User Manual  
Parity RAID uses less capacity for protection and is the preferred method to reduce the cost per megabyte for larger  
installations. Mirroring requires 100% increase in capacity to protect the data whereas the above example only requires a  
50% increase. The required capacity decreases as the number of disks in the group increases.  
Just Bunch of Disks (JBOD, Contiguous)  
The JBOD here (also known as Contiguous) means a logical drive that can either be an entire disk drive or a segment of a  
single disk drive. For this card, JBOD function only supports one disk. JBOD here is a Contiguous configuration option  
when “Create RAID Group” in SATARAID5 Manager Utility.  
3. Installation Procedures  
1. Power down the computer system.  
2. Insert the Host card into an available bus slot.  
3. Power ON  
4. Install Device Driver as section 5 Software Driver Installation.  
5. Remove all the existing SATARaid GUI (or Java SATARaid GUI) to ensure your new SATARaid5 GUI can  
work properly.  
6. Install a new SATARaid5 GUI.  
7. Power down the computer system again.  
8. Connect Hard Drives to SATA Ports.  
9. Power ON  
10. If you connect the used HDDs to SATA Ports, Press CTRL+S or F4 and then delete the Raid setting on every used  
HDD when BIOS booting  
11. Use SATARAID5 Manager GUI for RAID Group creating  
If 1 Disk, please select “Make Pass-Thru” option in Device Menu or “Concatenate” or “Contiguous” option in Create  
RAID Group Menu  
If 2 Disks, don’t select “Parity RAID” or “Mirrored Striped” setting  
If 3 Disks, don’t select “Mirrored Striped” setting  
12. Click “Task Manager” to make sure Raid setting is completed. It shall be “Green” color or “Blue” color on the selected  
components. RAID5 setting may cost hours for component ready and function available, please be patient for that.  
13. Use Device Manager for hard disk initialization, partition and formatting.  
4. BIOS Setting (RAID Setting)  
Creating and deleting RAID sets is a function found in the BIOS. During boot up, the RAID setting message will appear  
and pause for a few moments to allow the user to choose what to do. This board will act as normal NON-RAID card  
when BIOS not configured for RAID. Just proceed to Software Installation section directly. If you use traditional parallel  
ATA HDD, make sure your hard drives be set up as master mode before the RAID setting.  
4.1. Creating Striped Sets (RAID 0)  
1. As the BIOS boots, Press CTRL+S or F4 to enter the raid bios utility.  
2. Select Create RAID set. Press Enter.  
3. Select RAID 0 then press Enter.  
4. Select Number of hard drive. Press Enter.  
4. Select RAID size. Press Enter.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
SATAII 4 port PCI RAID Card RC217  
User Manual  
5. Press Y to save your settings.  
6. Press CTRL+E and then press Y to exit the setup.  
7. Continue with conventional Fdisk and Format steps as if you are installing a conventional hard drive.  
8. Your RAID configuration is complete. Please proceed to software installation section.  
4.2. Creating Mirrored Sets (RAID 1)  
1. As the BIOS boots, Press CTRL+S or F4 to enter the raid bios utility.  
2. Select Create RAID set. Press Enter.  
3. Select RAID 1 then press Enter.  
4. Select Auto configuration. Press Enter.  
5. Press Y to save your settings.  
6. Press CTRL+E and then press Y to exit the setup.  
7. Continue with conventional Fdisk and Format steps as if you are installing a conventional hard drive.  
8.Your RAID configuration is complete. Please proceed to software installation section.  
4.3. Creating a Mirrored-Striped Set (RAID 10)  
1. As the BIOS boots, press CTRL+S or F4 to enter the raid bios utility.  
2. Select Create RAID set. Press F2.  
3. Select RAID 10 then press Enter.  
4. Select Auto config. Press Enter.  
5. Press Y and then press ESC to exit the setup.  
6. Continue with conventional Fdisk and Format steps as if you are installing a conventional hard drive.  
7.Your RAID configuration is complete. Please proceed to software installation section.  
4.4. Creating Parity RAID (RAID 5)  
1. As the BIOS boots, Press CTRL+S or F4 to enter the raid bios utility.  
2. Select Create RAID set. Press Enter.  
3. Select RAID 5 then press Enter.  
4. Select Auto configuration. Press Enter.  
5. Press Y to save your settings.  
4.5. Creating JBOD Sets  
1. As the BIOS boots, Press CTRL+S or F4 to enter the raid bios utility.  
2. Select Create RAID set. Press Enter.  
3. Select JBOD (Single) then press Enter.  
4. Select JBOD Drives. Press Enter.  
5. Select RAID size. Press Enter.  
6. Press Y to save your settings.  
4.6. Creating Spare Drive  
1. As the BIOS boots, Press CTRL+S or F4 to enter the raid bios utility.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
SATAII 4 port PCI RAID Card RC217  
User Manual  
2. Select Create RAID set. Press Enter.  
3. Select Spare Drive then press Enter.  
4. Select Spare Drives. Press Enter.  
5. Select RAID size. Press Enter.  
6. Press Y to save your settings.  
4.7. Deleting RAID Sets  
1. As the BIOS boots, Press CTRL+S or F4 to enter the raid bios utility.  
2. Select Delete RAID set. Press Enter.  
3. Answer Y to remove the RAID set. If the RAID set being deleted is a Striped set, then all of the data will be lost. If the set  
being deleted is a Mirrored set, then the data will remain intact and accessible on both drives.  
4.8. Rebuilding Mirrored Sets (RAID 1)  
1. After replacing the failed hard drives boot the BIOS, Press CTRL+S or F4 to enter the raid bios utility.  
2. Select Rebuild RAID 1 set. Press Enter.  
3. Select Rebuild Hard Drive. Press Enter.  
4. Answer Y to rebuild the Mirrored set of hard drive.  
4.9. Resolving Conflict  
When a RAID set is created, the metadata written to the disk includes drive connection information (Primary and  
Secondary). If, after a disk failure, the replacement disk was previously part of a RAID set (or used in another system), it  
may have conflicting metadata, specifically in reference to the drive connection information. If so, this will prohibit the  
RAID set from being either created or rebuilt, In order for the RAID set to function properly, this old metadata must be  
first overwritten with the new metadata. To resolve this, select Resolve Conflicts, and the correct metadata, including the  
correct drive connection information, will be written to the replacement disk.  
5. Software Driver Installation  
5.1. Windows Vista/2000/XP/2003 Fresh Installation  
1. Power off the system. Connect the hard drives to the controller card and insert the controller card into a PCI slot.  
Power up the system.  
2. Put your Windows Vista//2000/XP CD into the CD-ROM/DVD drive, or the 2000/XP boot diskette #1 in the floppy drive  
if your system cannot boot from the CD.  
3. Press F6 for third party SCSI or driver installation at the beginning of text mode installation. Press 's' when setup asks  
if you want to specify an additional device and insert the Driver CD. Press 'Enter' and select 'E:\Raid5 SATA2_4Port  
\SiI3124\Windows\Driver'.  
4. Press 'Enter' to continue on with text mode setup.  
5. Follow the setup instructions to select your choice for partition and file system.  
6. After setup examines your disks, it will copy files to Windows 2000 installation folders and restart the system. The  
setup program will continue and finish the installation after restart.  
7. Waiting until Windows finishes installing devices, regional settings, networking settings, components, and final set of  
tasks, reboot the system if it is required.  
8. See instructions in section 5.3 to verify controller was installed correctly.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
SATAII 4 port PCI RAID Card RC217  
User Manual  
5.2. Adding the controller card to an existing Windows Vista/2000/XP/2003 Installation  
1. Power off the system. Connect the hard drives to the controller card and insert the controller card into a PCI slot.  
Power up the system.  
2. During OS boot up, Windows will display the 'Found New Hardware Wizard'. Click 'Next'.  
3. Select 'Search for a suitable driver for my device (Recommended)' and Click 'Next'.  
4. Insert the Driver CD in your CD-ROM/DVD drive, check Specify a location, uncheck the other boxes, click Next, type in  
E:\ (If your CD-ROM/DVD is E:\). Click Browse.  
5. Points specify a location, example E:\ Raid5 SATA2_4Port \ SiI3124 \ Windows \ Driver, click Open then OK.  
6. When the wizard indicates that it found a driver for the device click 'Next'.  
7. If the 'Digital Signature Not Found' dialog appears, click 'Yes' to continue installing the driver.  
8. The wizard will now copy the required files to the system and start the driver. After starting the driver the wizard will  
display a completion dialog, click 'Finish' to exit the wizard.  
9. See instructions in section 5.3 to verify controller was installed correctly.  
5.3. Verifying controller installation under Windows Vista/2000/XP/2003  
1. Right click on 'My Computer' icon, select 'Properties', left click on 'Hardware' tab and then on 'Device Manager'  
button.  
2. Double click on 'SCSI and RAID Controllers', If there is no yellow '!' or '?' in front of 'Silicon Image SiI 3124 SoftRaid5  
Controller', the driver is started correctly.  
3. To view information about the devices attached to the controller, use the SiICfg Utility and click on the device from the  
list.  
5.4. Update new driver on Windows Vista/2000/XP/2003 with existing driver  
1. Right click on 'My Computer' and select 'Properties'. Under the 'System Properties' section, click on  
'Hardware' tab and then on 'Device Manager' click 'SCSI and RAID Controller' and right click 'Silicon Image SiI 3124  
SoftRaid5 Controller'.  
2. Click 'Driver', 'Update Driver' and select 'Search for a suitable driver for my device [Recommended]'. Insert the  
Driver CD. Press 'Enter' and select 'E:\ Raid5 SATA2_4Port\SiI3124\Windows \Driver'. Click 'Next' and complete the  
driver installation.  
3. System will go through the enumeration process and install the driver. At the end of the process, click 'Yes' to reboot  
your system when necessary.  
4. See instructions in section 5.3 to verify controller was installed correctly.  
Thank you for purchasing a quality Rosewill Product.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Razor Mobility Scooter E100 User Guide
RCA Clock Radio RC170I User Guide
RedMax Trimmer BT280 User Guide
RIDGID Saw R8452 User Guide
Samsung DVD Player DVDL100 User Guide
Samsung Radio Antenna 21 869 User Guide
Sanyo Camcorder VPC CA9 BK User Guide
Scag Power Equipment Lawn Mower SW36 13KH User Guide
Sceptre Technologies Flat Panel Television X37 User Guide
Sega Video Games MAN S075 UK User Guide