Rheem PowerVent Induced Draft Gas Water Heater with the Guardian System™
Available in 40 and 50 US Gallon Models
ꢀ
ꢀ
6-Year Limited Tank Warranty*
1-Year Limited Parts Warranty*
Environmentally
Friendly Burner
Guardian System
Air/fuel shut-off system offers double
•
Low NOx design for low
protection
•
nitrous oxide emissions
Maintenance free –
•
no filter to clean
High Altitude Compliant
Flammable
Models certified up to 4,500 feet above
sea level
•
Vapour Detection Sensor
Protective control system
•
Self-Cleaning
that disables the heater in
the presence of flammable
vapour accumulation
EverKleen™ patented system fights
•
sediment build-up
Reduces fuel costs
Provides more hot water
•
Flexible Venting
Options
•
Longer Life
Long venting lengths up to 100 feet
•
Patented magnesium anode rod design
•
PVC, ABS, or CPVC vent pipe options
•
incorporates a special resistor that
protects the tank
Vertical or horizontal termination
•
New Quiet Blower
from corrosion.
Provides longer
tank life than using
standard magnesium
anode rods
Less noise than ever before
•
•
®
Self-Diagnostic
System
Integrated self-diagnos-
tic system control takes
the guess work away
•
** See Residential Warranty Information Brochure for
complete warranty information.
CROSS REFERENCE AND SPECIFICATIONS
DESCRIPTION
FEATURES
ROUGHING IN DIMENSIONS (SHOWN IN INCHES)
ENERGY INFO.
NEW
FVIR
MODEL
NUMBER
HT. TO
TOP OF
ASSEMBLY
A
HT. TO
GAS
CONN.
D
WATER
CONN.
CNTR.
E
HT. TO
SIDE T&P
VALVE
F
WATER
CONN.
SIZE
G
PREVIOUS
MODEL
NUMBER
FIRST HOUR
DEL. G.P.H.
NAT.
TANK
HT.
B
SHIP.
WT.
(LBS)
ENERGY
FACTOR
NATURAL
GALLON / LITRE
CAPACITY
GAS INPUT IN
THOUS. BTU/HR.
RECOVERY IN
G.P.H. 100° RISE
DIAM.
C
40 / 151
40 / 151
50 / 189
50 / 189
PVS40-36
PVS40-36P
PVS50-36
PVS50-36P
PVS40-36FV
PVS40-34PFV
PVS50-36FV
PVS50-34PFV
36
34
36
34
30.5
28.8
30.5
28.8
67
67
80
80
61-1/2
61-1/2
61-1/2
61-1/2
50-1/2 20-1/4
50-1/2 20-1/4
50-1/2 22-1/4
50-1/2 22-1/4
14
14
14
14
8
8
8
8
44
44
44
44
3/4
3/4
3/4
3/4
152
152
176
176
0.59
0.59
0.58
0.58
POWER VENT
ASSEMBLY
VENTING INFORMATION FOR 2" VENTS
VENTING INFORMATION FOR 3" VENTS
NUMBER OF
MINIMUM
MAXIMUM
NUMBER OF
MINIMUM
MAXIMUM
90° ELBOWS
WITH VENT
TERMINAL
NUMBER
OF 45°
ELBOWS
PIPE
PIPE
LENGTH
(FT.)
90° ELBOWS
NUMBER
OF 45°
ELBOWS
PIPE
PIPE
LENGTH
(FT.)
G
HOT
LENGTH
REQ. (FT.)
WITH VENT
TERMINAL
LENGTH
REQ. (FT.)
G
WATER
CONNECTION
COLD
WATER
CONNECTION
One (1)
One (1)
Two (2)
Two (2)
Three (3)
None
One (1)
None
4.0
4.0
4.0
4.0
4.0
44.0
41.0
38.0
35.0
32.0
One (1)
One (1)
Two (2)
Two (2)
Three (3)
Three (3)
Four (4)
Four (4)
Five (5)
None
One (1)
None
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
95.0
92.5
90.0
87.5
85.0
82.5
80.0
77.5
75.0
E
C
T&P FITTING
3/4" N.P.T.
One (1)
None
One (1)
None
One (1)
None
For the 2" vent, one 90° elbow is approximately equal to
6 feet of pipe. One 45° elbow is approximately equal to
3 feet of pipe.
A B
One (1)
None
F
1/2"
For the 3" vent, one 90° elbow is approximately equal to
5 feet of pipe. One 45° elbow is approximately equal to
2.5 feet of pipe.
D
In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
Rheem Manufacturing Company • Water Heater Division
Rheem Canada Ltd./Ltée,128 Barton Street West, Hamilton, Ontario L8N 3P3
09/06 WP
FORM NO. 101-85CAN
Download from Www.Somanuals.com. All Manuals Search And Download.
|