Renesas Computer Hardware M16C 29 User Guide

Renesas Starter Kit for M16C/29  
Quick Start  
1. Installation  
Do not connect the E8a module until the software support has been installed.  
1
Insert the CD into your computers CD-ROM drive. The CD should automatically run the installation program. If the installer does not start, browse to  
the RSK directory from the CD root folder and double click on setup.exe.  
2
3
4
5
6
7
8
9
The installer will ask you which language is to be used, please choose the appropriate one.  
On the first screen of the installer proper, click <Next>.  
The License Agreement will be shown, click <Yes>.  
The next screen asks you to pick the world region – please select and click <Next>.  
Select the RSK you wish to install and click <Next>.  
The destination folders are specified on the next screens. It is recommended to accept the default settings. Click <Next> to continue.  
Click <Next> on all screens until the Installation process commences.  
After the installation the machines site code will be shown, this is not important at this stage, click <Next> then <Finish>.  
10 The Auto-update dialog box will be launched. Configure the Auto-update settings dialog to allow the installation to be checked for available updates.  
D006174_11_S01_V04  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Programming and Debug  
26 Ensure the SessionM16C_E8a_SYSTEM session in the right hand drop down list  
on the tool bar is selected.  
27 Click the <Connect> button on the debug toolbar  
28 The Emulator mode” wizard will be shown.  
Select the correct MCU group (M16C/29) and device type  
(e.g. M30290FC for RSKM16C29 )  
Please note that the “Emulator mode” view shown here will only appear the FIRST time you  
connect to the target within a project. On subsequent connections the “Emulator setting”  
dialog will appear, please choose the same options to connect – refer to the RSKM16C29  
Tutorial manual for details.  
29 Select Erase Flash and Connect. If the E8a is to provide power to the CPU board, select  
Power Target from Emulator” and choose the 5.0Voption. Otherwise connect a 5V centre  
positive supply.  
30 Click <Next>  
31 Enter FF000 for the firmware location. It is recommended that the E8a firmware location  
is towards the top of the memory map.  
32 Enter 3300 for the Work RAM location. It is recommended that the Work RAM is towards the  
top of the memory map.  
33 Ensure that the checkboxDebugging of program that uses WDT” is not checked.  
34 Click <Next>.  
35 The MCU Setting” view will be shown. Leave the default options as shown.  
36 Click <Finish>.  
Note: The first time the E8a is connected, you may be asked to choose a driver, select  
“Renesas Communications”, after a few seconds the “Interface” and “Channel” numbers will be automatically displayed, click <Close>  
on the dialog.  
37 Accept any dialog warning that another version of E8a firmware is necessary to work with the application. Allow download of firmware to complete,  
this may take several seconds.  
38 Right click on the download module listed in the left hand pane and select Download. The code  
will be downloaded to the microcontroller. This may take several seconds.  
39 Click the <Reset – Go> button.  
The code will run and you will see the LEDs flash on the board.  
40 Click the <Stop> button.  
The code will stop and the source code will be opened at the current program counter.  
D006174_11_S01_V04  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. Next Step  
After you have completed this quick start procedure, please review the tutorial code and sample code that came with the kit. You can add projects to the  
current workspace by selecting (Project > Insert Project) from the main menu. The tutorials will help you understand the device and development process  
using Renesas Development Tools.  
The Hardware manual supplied with this RSK is current at the time of publication. Please check for any updates to the device manual from the Renesas  
6. Renesas M16C Compiler  
The version of the compiler provided with this RSK is fully functional but time limited. You have 60 days to evaluate the full product before the compiler will  
limit the code linker to 64k bytes. Full licensed M16C compiler versions are available from your Renesas supplier.  
7. Support  
Online technical support and information is available at: www.renesas.com/renesas_starter_kits  
Technical Contact Details  
Note on Autoupdate: The Autoupdater is configured to automatically add itself to the Startup folder in the Windows Start Menu and use the registry  
defaults for access to the web. After restarting the machine the Icon will appear in the System Tray next to the clock. To change the settings or access  
Autoupdate simply right-click on the icon and use the menu that appears.  
© Renesas Technology Europe Ltd 2007.  
© Renesas Technology Corporation 2007.  
D006174_11_S01_V04  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Radio Shack Cordless Telephone ET 1110 User Guide
RCA Portable Speaker PRO X33AV User Guide
Renesas Computer Monitor R61509V User Guide
Roland Electronic Keyboard PK 7 User Guide
Rosewill Network Card RC 502 User Guide
Samsung Car Satellite TV System HL R5688W User Guide
Samsung Computer Monitor 152V User Guide
Samsung Digital Photo Frame spf 72v User Guide
Samsung High Chair DVD VR375 User Guide
Sennheiser Headphones HD 515 User Guide