Renesas Computer Hardware H8 3007 User Guide

REJ10J0616-0400  
H8/3048 Group, H8/3052 Group, H8/3062 Group,  
H8/3067 Group, H8/3007 Group FP-100B/TFP-100B  
User System Interface Cable for E6000 Emulator  
HS3064BECH61H User’s Manual  
HS3064BECH61HE  
Renesas Microcomputer Development Environment System  
H8 Family / H8/300H Series  
Rev.4.00  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Revision Date: Aug. 20, 2008  
Notes regarding these materials  
1. This document is provided for reference purposes only so that Renesas customers may select the appropriate  
Renesas products for their use. Renesas neither makes warranties or representations with respect to the  
accuracy or completeness of the information contained in this document nor grants any license to any  
intellectual property rights or any other rights of Renesas or any third party with respect to the information in  
this document.  
2. Renesas shall have no liability for damages or infringement of any intellectual property or other rights arising  
out of the use of any information in this document, including, but not limited to, product data, diagrams, charts,  
programs, algorithms, and application circuit examples.  
3. You should not use the products or the technology described in this document for the purpose of military  
applications such as the development of weapons of mass destruction or for the purpose of any other military  
use. When exporting the products or technology described herein, you should follow the applicable export  
control laws and regulations, and procedures required by such laws and regulations.  
4. All information included in this document such as product data, diagrams, charts, programs, algorithms, and  
application circuit examples, is current as of the date this document is issued. Such information, however, is  
subject to change without any prior notice. Before purchasing or using any Renesas products listed in this  
document, please confirm the latest product information with a Renesas sales office. Also, please pay regular  
and careful attention to additional and different information to be disclosed by Renesas such as that disclosed  
5. Renesas has used reasonable care in compiling the information included in this document, but Renesas  
assumes no liability whatsoever for any damages incurred as a result of errors or omissions in the information  
included in this document.  
6. When using or otherwise relying on the information in this document, you should evaluate the information in  
light of the total system before deciding about the applicability of such information to the intended application.  
Renesas makes no representations, warranties or guaranties regarding the suitability of its products for any  
particular application and specifically disclaims any liability arising out of the application and use of the  
information in this document or Renesas products.  
7. With the exception of products specified by Renesas as suitable for automobile applications, Renesas  
products are not designed, manufactured or tested for applications or otherwise in systems the failure or  
malfunction of which may cause a direct threat to human life or create a risk of human injury or which require  
especially high quality and reliability such as safety systems, or equipment or systems for transportation and  
traffic, healthcare, combustion control, aerospace and aeronautics, nuclear power, or undersea communication  
transmission. If you are considering the use of our products for such purposes, please contact a Renesas  
sales office beforehand. Renesas shall have no liability for damages arising out of the uses set forth above.  
8. Notwithstanding the preceding paragraph, you should not use Renesas products for the purposes listed below:  
(1) artificial life support devices or systems  
(2) surgical implantations  
(3) healthcare intervention (e.g., excision, administration of medication, etc.)  
(4) any other purposes that pose a direct threat to human life  
Renesas shall have no liability for damages arising out of the uses set forth in the above and purchasers who  
elect to use Renesas products in any of the foregoing applications shall indemnify and hold harmless Renesas  
Technology Corp., its affiliated companies and their officers, directors, and employees against any and all  
damages arising out of such applications.  
9. You should use the products described herein within the range specified by Renesas, especially with respect  
to the maximum rating, operating supply voltage range, movement power voltage range, heat radiation  
characteristics, installation and other product characteristics. Renesas shall have no liability for malfunctions or  
damages arising out of the use of Renesas products beyond such specified ranges.  
10. Although Renesas endeavors to improve the quality and reliability of its products, IC products have specific  
characteristics such as the occurrence of failure at a certain rate and malfunctions under certain use  
conditions. Please be sure to implement safety measures to guard against the possibility of physical injury, and  
injury or damage caused by fire in the event of the failure of a Renesas product, such as safety design for  
hardware and software including but not limited to redundancy, fire control and malfunction prevention,  
appropriate treatment for aging degradation or any other applicable measures. Among others, since the  
evaluation of microcomputer software alone is very difficult, please evaluate the safety of the final products or  
system manufactured by you.  
11. In case Renesas products listed in this document are detached from the products to which the Renesas  
products are attached or affixed, the risk of accident such as swallowing by infants and small children is very  
high. You should implement safety measures so that Renesas products may not be easily detached from your  
products. Renesas shall have no liability for damages arising out of such detachment.  
12. This document may not be reproduced or duplicated, in any form, in whole or in part, without prior written  
approval from Renesas.  
13. Please contact a Renesas sales office if you have any questions regarding the information contained in this  
document, Renesas semiconductor products, or if you have any other inquiries.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IMPORTANT INFORMATION  
READ FIRST  
• READ this user's manual before using this user system interface cable.  
• KEEP the user's manual handy for future reference.  
Do not attempt to use the user system interface cable until you fully understand its  
mechanism.  
User System Interface Cable:  
Throughout this document, the term "user system interface cable" shall be defined as the  
following product produced only by Renesas Technology Corp. excluding all subsidiary products.  
User system interface cable (HS3064BECH61H)  
The user system or a host computer is not included in this definition.  
Purpose of the User System Interface Cable:  
This user system interface cable is for connecting the emulator station and user system. This  
user system interface cable must only be used for the above purpose.  
Improvement Policy:  
Renesas Technology Corp. (including its subsidiaries, hereafter collectively referred to as  
Renesas) pursues a policy of continuing improvement in design, performance, functions, and  
safety of the user system interface cable. Renesas reserves the right to change, wholly or partially,  
the specifications, design, user's manual, and other documentation at any time without notice.  
Target User of the User System Interface Cable:  
This user system interface cable should only be used by those who have carefully read and  
thoroughly understood the information and restrictions contained in the user's manual. Do not  
attempt to use the user system interface cable until you fully understand its mechanism.  
It is highly recommended that first-time users be instructed by users that are well versed in the  
operation of the user system interface cable.  
I
Download from Www.Somanuals.com. All Manuals Search And Download.  
LIMITED WARRANTY  
Renesas warrants its user system interface cables to be manufactured  
in accordance with published specifications and free from defects in  
material and/or workmanship. Renesas will repair or replace any  
user system interface cables determined to be defective in material  
and/or workmanship. User system interface cables are wearing parts  
which Renesas will not repair or replace if damaged and/or worn  
through use. The foregoing shall constitute the sole remedy for any  
breach of Renesas’ warranty. This warranty extends only to you, the  
original Purchaser. It is not transferable to anyone who subsequently  
purchases the user system interface cable from you. Renesas is not  
liable for any claim made by a third party or made by you for a third  
party.  
DISCLAIMER  
RENESAS MAKES NO WARRANTIES, EITHER EXPRESS OR  
IMPLIED, ORAL OR WRITTEN, EXCEPT AS PROVIDED  
HEREIN, INCLUDING WITHOUT LIMITATION THEREOF,  
WARRANTIES AS TO MARKETABILITY, MERCHANTABILITY,  
FITNESS FOR ANY PARTICULAR PURPOSE OR USE, OR  
AGAINST INFRINGEMENT OF ANY PATENT. IN NO EVENT  
SHALL RENESAS BE LIABLE FOR ANY DIRECT, INCIDENTAL  
OR CONSEQUENTIAL DAMAGES OF ANY NATURE, OR  
LOSSES OR EXPENSES RESULTING FROM ANY DEFECTIVE  
USER SYSTEM INTERFACE CABLE, THE USE OF ANY USER  
SYSTEM INTERFACE CABLE, OR ITS DOCUMENTATION,  
EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.  
EXCEPT AS EXPRESSLY STATED OTHERWISE IN THIS  
WARRANTY, THIS USER SYSTEM INTERFACE CABLE IS SOLD  
"AS IS ", AND YOU MUST ASSUME ALL RISK FOR THE USE  
AND RESULTS OBTAINED FROM THE USER SYSTEM  
INTERFACE CABLE.  
II  
Download from Www.Somanuals.com. All Manuals Search And Download.  
State Law:  
Some states do not allow the exclusion or limitation of implied warranties or liability for  
incidental or consequential damages, so the above limitation or exclusion may not apply to you.  
This warranty gives you specific legal rights, and you may have other rights which may vary from  
state to state.  
The Warranty is Void in the Following Cases:  
Renesas shall have no liability or legal responsibility for any problems caused by misuse,  
abuse, misapplication, neglect, improper handling, installation, repair or modifications of the user  
system interface cable without Renesas’ prior written consent or any problems caused by the user  
system.  
All Rights Reserved:  
This user's manual and user system interface cable are copyrighted and all rights are reserved  
by Renesas. No part of this user's manual, all or part, may be reproduced or duplicated in any  
form, in hard-copy or machine-readable form, by any means available without Renesas’ prior  
written consent.  
Other Important Things to Keep in Mind:  
1. Circuitry and other examples described herein are meant merely to indicate the characteristics  
and performance of Renesas’ semiconductor products. Renesas assumes no responsibility for  
any intellectual property claims or other problems that may result from applications based on  
the examples described herein.  
2. No license is granted by implication or otherwise under any patents or other rights of any third  
party or Renesas.  
Figures:  
Some figures in this user's manual may show items different from your actual system.  
Limited Anticipation of Danger:  
Renesas cannot anticipate every possible circumstance that might involve a potential hazard.  
The warnings in this user's manual and on the user system interface cable are therefore not all  
inclusive. Therefore, you must use the user system interface cable safely at your own risk.  
III  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SAFETY PAGE  
READ FIRST  
• READ this user's manual before using this user system interface cable.  
• KEEP the user's manual handy for future reference.  
Do not attempt to use the user system interface cable until you fully understand its  
mechanism.  
DEFINITION OF SIGNAL WORDS  
This is the safety alert symbol. It is used to alert you to potential personal  
injury hazards. Obey all safety messages that follow this symbol to avoid  
possible injury or death.  
DANGER  
DANGER indicates an imminently hazardous situation which, if not  
avoided, will result in death or serious injury.  
WARNING  
WARNING indicates a potentially hazardous situation which, if not  
avoided, could result in death or serious injury.  
CAUTION  
CAUTION indicates a potentially hazardous situation which, if not  
avoided, may result in minor or moderate injury.  
CAUTION  
CAUTION used without the safety alert symbol indicates a  
potentially hazardous situation which, if not avoided, may result  
in property damage.  
NOTE emphasizes essential information.  
IV  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARNING  
Observe the precautions listed below. Failure to do so  
will result in a FIRE HAZARD and will damage the user  
system and the emulator product or will result in  
PERSONAL INJURY. The USER PROGRAM will be  
LOST.  
1. Do not repair or remodel the emulator product by  
yourself for electric shock prevention and quality  
assurance.  
2. Always switch OFF the E6000 emulator and user system  
before connecting or disconnecting any CABLES or  
PARTS.  
3. Always before connecting any CABLES, make sure that  
pin 1 on both sides are correctly aligned.  
V
Download from Www.Somanuals.com. All Manuals Search And Download.  
VI  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Preface  
Thank you for purchasing this user system interface cable (HS3064BECH61H) for the Renesas’  
original microcomputers H8/3048 group, H8/3052 group, H8/3062 group, H8/3067 group, and  
H8/3007 group.  
The HS3064BECH61H is a user system interface cable that connects the H8/3048 group, H8/3052  
group, H8/3062 group, H8/3067 group, H8/3007 group E6000 emulator (HS3064BEPI61H;  
hereinafter referred to as the emulator) to the IC socket for an FP-100B/TFP-100B package for the  
H8/3048 group, H8/3052 group, H8/3062 group, H8/3067 group, H8/3007 group MCU on the  
user system.  
i
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
Section 1 Configuration....................................................................................1  
Section 2 Connection Procedures......................................................................3  
2.1 Connecting User System Interface Cable to Emulator Station .........................................3  
2.2 Connecting User System Interface Cable to User System ................................................5  
2.2.1 Installing IC Socket..............................................................................................5  
2.2.2 Soldering IC Socket.............................................................................................5  
2.2.3 Inserting Cable Head............................................................................................6  
2.2.4 Fastening Cable Head ..........................................................................................6  
2.2.5 Fastening Cable Body..........................................................................................8  
2.3 Recommended Dimensions for User System Mount Pad .................................................9  
2.4 Dimensions for User System Interface Cable Head..........................................................10  
2.5 Resulting Dimensions after Connecting User System Interface Cable.............................11  
Section 3 Installing the MCU to the User System.............................................12  
Section 4 Verifying Operation...........................................................................14  
Section 5 Notice.................................................................................................15  
ii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Section 1 Configuration  
CAUTION  
Use an IC149-100-054-B51 socket (manufactured by  
YAMAICHI ELECTRONICS Co., Ltd.) for the FP-100B/  
TFP-100B package IC socket on the user system.  
Figure 1 shows the configuration of the HS3064BECH61H user system interface cable for the  
FP-100B/TFP-100B package.  
To emulator station  
CTS screws (M3 x 6 mm)  
for fastening the emulator station  
Cable body  
Screws (M2.6 x 12 mm)  
with flat washers  
(for fastening cable head)  
Screws (M2.6 x 6 mm)  
with flat washers  
Socket cover  
IC socket  
Cable head  
User system  
Figure 1 HS3064BECH61H User System Interface Cable  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Table 1 lists the HS3064BECH61H components. Please make sure you have all of these  
components when unpacking.  
Table 1  
HS3064BECH61H Components  
No. Component  
Quantity  
Remarks  
1
2
3
4
Cable body  
Cable head  
IC socket  
1
1
1
1
For the FP-100B/TFP-100B package  
Socket cover  
For installing an FP-100B/TFP-100B-packaged  
MCU  
5
6
Screws (M2.6 x 12 mm)  
Screws (M2.6 x 6 mm)  
4
4
For fastening cable head (with four flat washers)  
For installing an FP-100B/TFP-100B-packaged  
MCU (with four flat washers)  
7
8
CTS screws (M3 x 6 mm)  
Documentation  
2
1
For fastening the emulator station  
User’s manual for HS3064BECH61H (this  
manual)  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
Section 2 Connection Procedures  
2.1  
Connecting User System Interface Cable to Emulator Station  
WARNING  
Observe the precautions listed below. Failure to do so  
will result in a FIRE HAZARD and will damage the user  
system and the emulator product or will result in  
PERSONAL INJURY. The USER PROGRAM will be  
LOST.  
1. Always switch OFF the user system and the emulator  
product before the USER SYSTEM INTERFACE CABLE  
is connected to or removed from any part. Before  
connecting, make sure that pin 1 on both sides are  
correctly aligned.  
2. The user system interface cable dedicated to the  
emulator must be used.  
To connect the cable body to the emulator station, follow the instructions below.  
1. Make sure the user system and emulator station are turned off.  
CAUTION  
When connecting or removing the user system interface  
cable, apply force only in the direction suitable for  
connection or removal, while making sure not to bend or  
twist the cable or connectors. Otherwise, the connectors will  
be damaged.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2. After making sure the direction of the cable body connector is correct, firmly insert the cable  
body connector into the emulator station socket, and fasten the emulator station with two CTS  
screw (M3 x 6 mm) (figure 2).  
Emulator station  
E 6 0 0 0  
Cable body connector  
CTS screws (M3 x 6 mm)  
User system interface cable  
Figure 2 Connecting User System Interface Cable to Emulator Station  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.2  
Connecting User System Interface Cable to User System  
WARNING  
Always switch OFF the user system and the emulator  
product before the USER SYSTEM INTERFACE CABLE  
is connected to or removed from any part. Before  
connecting, make sure that pin 1 on both sides are correctly  
aligned. Failure to do so will result in a FIRE HAZARD and  
will damage the user system and the emulator product or  
will result in PERSONAL INJURY. The USER PROGRAM will  
be LOST.  
To connect the cable head to the user system, follow the instructions below.  
2.2.1 Installing IC Socket  
After checking the location of pin 1 on the IC socket, apply epoxy resin adhesive to the bottom of  
the IC socket for an FP-100B/TFP-100B package, and fasten it to the user system before  
soldering.  
2.2.2  
Soldering IC Socket  
After fastening, solder the IC socket for an FP-100B/TFP-100B package to the user system. Be  
sure to completely solder the leads so that the solder slops gently over the leads and forms solder  
fillets. (Use slightly more solder than the MCU.)  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2.2.3  
Inserting Cable Head  
CAUTION  
Check the location of pin 1 before inserting.  
Align pin 1 on the IC socket for an FP-100B/TFP-100B package on the user system with pin 1 on  
the user system interface cable head, and insert the user system interface cable head into the IC  
socket on the user system, as shown in figure 3.  
2.2.4  
Fastening Cable Head  
CAUTION  
1. Use a Philips-type screwdriver whose head matches  
the screw head.  
2. The tightening torque must be 0.294 N•m or less.  
If the applied torque cannot be accurately measured,  
stop tightening when the force required to turn the screw  
becomes significantly greater than that needed when first  
tightening. If a screw is tightened too much, the screw  
head may break or an IC socket contact error may be  
caused by a crack in the IC socket solder.  
3. If the emulator does not operate correctly, cracks might  
have occurred in the solder. Check conduction with  
a tester and re-solder the IC socket if necessary.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Fasten the user system interface cable head to the IC socket for an FP-100B/TFP-100B package  
on the user system with the four screws (M2.6 x 12 mm; with four flat washers) provided. Each  
screw should be tightened a little at a time, alternating between screws on opposing corners. Take  
special care, such as manually securing the IC socket soldered area, to prevent the soldered IC  
socket from being damaged by overtightening the screws or twisting the components.  
Screws (M2.6 x 12 mm)  
with flat washers  
Cable head  
Pin 1  
IC socket  
(IC149-100-054-B51  
manufactured by  
YAMAICHI ELECTRONICS Co., Ltd.)  
User system  
Figure 3 Connecting User System Interface Cable to User System  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.2.5  
Fastening Cable Body  
Connect the cable body to the cable head.  
Cable body  
Removing  
Push the remove jigs.  
Remove jig  
Cable head  
User system  
Figure 4 Fastening Cable Body  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2.3  
Recommended Dimensions for User System Mount Pad  
Figure 5 shows the recommended dimensions for the mount pad (footprint) for the user system  
with an IC socket for an FP-100B/TFP-100B package (IC149-100-054-B51: manufactured by  
YAMAICHI ELECTRONICS Co., Ltd.). Note that the dimensions in figure 5 are somewhat  
different from those of the actual chip's mount pad.  
17.10 (min.)  
13.80 (max.)  
0.5 x 24 = 12.00 ± 0.05  
0.50 ± 0.05  
0.30 ± 0.05  
Unit: mm  
Figure 5 Recommended Dimensions for Mount Pad  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2.4  
Dimensions for User System Interface Cable Head  
The dimensions for the user system interface cable head are shown in figure 6.  
29.0  
18.5  
66.0  
Unit: mm  
Tolerance: ±0.5 mm  
Figure 6 Dimensions for User System Interface Cable Head  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2.5  
Resulting Dimensions after Connecting User System Interface Cable  
The resulting dimensions, after connecting the user system interface cable head to the user system,  
are shown in figure 7.  
Cable head  
Unit: mm  
Tolerance: ±0.5 mm  
IC socket  
(IC149-100-054-B51  
User system  
manufactured by  
YAMAICHI ELECTRONICS Co., Ltd.)  
Figure 7 Resulting Dimensions after Connecting User System Interface Cable  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Section 3 Installing the MCU to the User System  
CAUTION  
1. Check the location of pin 1 before inserting.  
2. Use a Philips-type screwdriver whose head matches  
the screw head.  
3. The tightening torque must be 0.294 N•m or less.  
If the applied torque cannot be accurately measured,  
stop tightening when the force required to turn the screw  
becomes significantly greater than that needed when first  
tightening. If a screw is tightened too much, the screw  
head may break or an IC socket contact error may be  
caused by a crack in the IC socket solder.  
4. If the MCU does not operate correctly, cracks might have  
occurred in the solder. Check conduction with a tester  
and re-solder the IC socket if necessary.  
Check the location of pin 1 before inserting the MCU into the IC socket on the user system, as  
shown in figure 8. After inserting the MCU, fasten the socket cover with the provided four screws  
(M2.6 x 6 mm; with four flat washers). Take special care, such as manually securing the IC  
socket soldered area, to prevent the IC socket from being damaged by overtightening the screws  
or twisting the components.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Screws (M2.6 x 6 mm)  
with flat washers  
Socket cover  
MCU  
Pin 1  
IC socket  
(IC149-100-054-B51  
manufactured by  
YAMAICHI ELECTRONICS Co., Ltd.)  
User system  
Figure 8 Installing MCU to User System  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Section 4 Verifying Operation  
1. Start up the emulator according to the procedures described in the H8/3048 Group, H8/3052  
Group, H8/3062 Group, H8/3067 Group, H8/3007 Group E6000 Emulator User's Manual  
(HS3064BEPI61HE).  
2. Verify the user system interface cable connections by accessing the external memory and ports  
to check the bus states of the pins with the MEMORY_FILL command (emulator command).  
If an error is detected, recheck the soldered IC socket and the location of pin 1.  
3. The emulator connected to this user system interface cable supports two kinds of clock  
sources: an emulator internal clock and an external clock on user system. For details, refer to  
the H8/3048 Group, H8/3052 Group, H8/3062 Group, H8/3067 Group, H8/3007 Group E6000  
Emulator User's Manual (HS3064BEPI61HE).  
To use the emulator internal clock  
Select the clock in the emulator station as the system clock (φ) by using the CLOCK  
command (emulator command).  
To use the external clock on the user system as the system clock  
Select target clock t or t2 with the CLOCK command (emulator command). Supply the  
external clock from the user system to the emulator by inputting the external clock from  
the EXTAL terminal on the cable head or connecting a crystal oscillator to the XTAL and  
EXTAL terminals. For details, refer to the section of Clock Pulse Generator, in the  
H8/3048 Group, H8/3052 Group, H8/3062 Group, H8/3067 Group, H8/3007 Group  
Hardware Manual.  
Figure 9 shows the clock oscillator circuit on the user system interface cable.  
R1 1 MΩ  
HCU04  
HCU04  
To E6000 emulator  
HCU04  
R2 270 Ω  
EXTAL XTAL  
Figure 9 Clock Oscillator Circuit  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Section 5 Notice  
1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable  
head before inserting the cable head into the user system IC socket.  
2. The dimensions of the recommended mount pad for the user system IC socket are different  
from those of the MCU.  
3. This user system interface cable is specifically designed for the HS3064BEPI61H emulator.  
Do not use this cable with any other emulator station.  
4. To prevent breaking of wires in the cable body, do not place heavy or sharp metal objects on  
the user system interface cable.  
5. While the emulator station is connected to the user system with the user system interface cable,  
force must not be applied to the cable head. Place the emulator station, user system interface  
cable, and user system as shown in the example in figure 10.  
Place components so that the cable body and cable head are  
parallel to the user system.  
Cable  
Emulator station  
Cable head is parallel  
to emulator station  
Cable head is parallel  
to user system  
User system  
Figure 10 User System Interface Cable Location Example  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
6. The P1 jumper is used for testing. A jumper pin is inserted in pin 1 side. Do not remove the  
inserted jumper pin.  
CAUTION  
Insert the jumper pin in pin 3 side for P4 jumper when pin  
10 of the MCU is not used as RESO. Otherwise the user  
system interface cable, the emulator product, and the user  
system will be damaged.  
P4  
P4 jumper  
3
1
Pin 10 of the MCU is used as RESO: Pin 1 side disconnected  
Pin 10 of the MCU is not used as RESO: Pin 3 side disconnected (setting at shipment)  
1
3
P1  
Figure 11 Jumper  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
H8/3048 Group, H8/3052 Group, H8/3062 Group,  
H8/3067 Group, H8/3007 Group FP-100B/TFP-100B  
User System Interface Cable  
for E6000 Emulator User's Manual  
Publication Date: Rev.3.00, March, 2003  
Rev.4.00, August 20, 2008  
Published by:  
Sales Strategic Planning Div.  
Renesas Technology Corp.  
Customer Support Department  
Global Strategic Communication Div.  
Renesas Solutions Corp.  
Edited by:  
© 2008. Renesas Technology Corp., All rights reserved. Printed in Japan.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Sales Strategic Planning Div. Nippon Bldg., 2-6-2, Ohte-machi, Chiyoda-ku, Tokyo 100-0004, Japan  
RENESAS SALES OFFICES  
Refer to "http://www.renesas.com/en/network" for the latest and detailed information.  
Renesas Technology America, Inc.  
450 Holger Way, San Jose, CA 95134-1368, U.S.A  
Tel: <1> (408) 382-7500, Fax: <1> (408) 382-7501  
Renesas Technology Europe Limited  
Dukes Meadow, Millboard Road, Bourne End, Buckinghamshire, SL8 5FH, U.K.  
Tel: <44> (1628) 585-100, Fax: <44> (1628) 585-900  
Renesas Technology (Shanghai) Co., Ltd.  
Unit 204, 205, AZIACenter, No.1233 Lujiazui Ring Rd, Pudong District, Shanghai, China 200120  
Tel: <86> (21) 5877-1818, Fax: <86> (21) 6887-7858/7898  
Renesas Technology Hong Kong Ltd.  
7th Floor, North Tower, World Finance Centre, Harbour City, Canton Road, Tsimshatsui, Kowloon, Hong Kong  
Tel: <852> 2265-6688, Fax: <852> 2377-3473  
Renesas Technology Taiwan Co., Ltd.  
10th Floor, No.99, Fushing North Road, Taipei, Taiwan  
Tel: <886> (2) 2715-2888, Fax: <886> (2) 3518-3399  
Renesas Technology Singapore Pte. Ltd.  
1 Harbour Front Avenue, #06-10, Keppel Bay Tower, Singapore 098632  
Tel: <65> 6213-0200, Fax: <65> 6278-8001  
Renesas Technology Korea Co., Ltd.  
Kukje Center Bldg. 18th Fl., 191, 2-ka, Hangang-ro, Yongsan-ku, Seoul 140-702, Korea  
Tel: <82> (2) 796-3115, Fax: <82> (2) 796-2145  
Renesas Technology Malaysia Sdn. Bhd  
Unit 906, Block B, Menara Amcorp, Amcorp Trade Centre, No.18, Jln Persiaran Barat, 46050 Petaling Jaya, Selangor Darul Ehsan, Malaysia  
Tel: <603> 7955-9390, Fax: <603> 7955-9510  
Colophon 6.2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
H8/3048 Group, H8/3052 Group,  
H8/3062 Group, H8/3067 Group,  
H8/3007 Group FP-100B/TFP-100B  
User System Interface Cable  
for E6000 Emulator User’s Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Quasar Battery Charger PAG User Guide
RCA Camcorder EZ101 User Guide
Regency Stove F3100 User Guide
Rhino Mounts Lawn Mower GK6072 User Guide
Samsung CD Player SW 208 User Guide
Samsung Home Theater System AH68 01008B User Guide
Samsung Microwave Oven CM1019 User Guide
SanDisk Camera Accessories 80 11 00893 User Guide
SanDisk Computer Drive Cruzer Contour User Guide
Sansui Flat Panel Television SLED3900 User Guide