Reliable Iron i500 User Guide

i500  
Professional Iron System  
i500A & i500B  
Professional Steam Cleaners  
Instruction Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
COMPONENTS  
1. Safety cap  
2. Wand to hold mono-hose up  
3. Iron power button  
4. Boiler power button  
5. Low water level light indicator  
6. Temperature regulating knob  
7. Steam button  
8. Steam regulation knob  
9. Manometer / pressure gauge  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CAUTION  
Do not leave the machine unattended while the plug is connected to  
the socket.  
The iron reaches very high temperatures and it keeps being very hot  
even 15 minutes after it’s been switching off. Be careful not to burn  
yourself.  
For complete safety, before filling the boiler, please disconnect the  
plug.  
While using the machine, never unscrew or remove the cap while  
under pressure (1). Before removing it, make sure that it does not  
give off steam anymore by shutting the boiler off, and pressing the  
steam iron button (7) to release all remaining steam.  
The machine has a special heating element. Only qualified  
technician should replace it.  
The safety cap (1) must be replaced with original parts only.  
TECHNICAL DATA  
Adjustable iron thermostat set from 60°C to 215°C  
Bimetallic safety iron thermostat with manual reset at 275°C  
Full aluminium-plated heating element at 800W – 120V  
Boiler power i500: 1000W  
Working pressure i500: 3,5 bar  
Tank nominal capacity of model i500: 2.5 litres  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TROUBLESHOOTING  
PROBLEM  
EXPLANATION  
SOLUTION  
Does  
steam go  
out from  
It may happen that, while filling the In order to solve the problem, we suggest  
tank, some water overfills the cap and using the machine as usual so that the  
flows inside the boiler wetting the insulating material dries up in about one  
the boiler? insulating material  
hour through the heat of the machine. In  
case you still have this problem after one  
working hour, please contact the service  
centre.  
Does the  
1) While filling the tank you may have 1) The problem will go on until the excess  
steam iron poured too much water into it.  
water is emptied. Keep the steam button  
depressed until the water in the tank is at  
the correct level.  
leak steam  
mixed with  
water?  
2) The iron plate has to be hot before 2) Please check that the temperature knob  
the steam passage  
is on the right position: “cotton °°°)”  
There is  
no steam  
coming out  
of the  
1) The steam knob (where supplied)  
might be closed  
1) Open the steam knob anticlockwise.  
2) The iron switch might be off  
3) The boiler switch might be off  
2) After the iron switch comes on, wait for 4  
minutes so that the iron plate gets hot.  
iron?  
3) After the boiler switch comes on, wait for  
10 minutes so the boiler produces steam.  
4) The water might be used up.  
1) The ironing board cover might not  
be able to absorb the steam  
completely  
4) Fill it following the instructions carefully.  
Does the  
ironing  
board get  
wet?  
1) You might use a thicker cover (or two  
covers) so to create a thicker surface to  
absorb the steam better. In case you are  
using a vacuum table, switch on the  
vacuum function each time you are using  
the steam  
2) The steam iron leaks steam mixed  
with water (Check by spraying some  
steam on a dry cloth)  
2) See # 2  
Does the  
Some dirty might have gone into the Fill the empty tank with 1 liter of water,  
steam leak tank with the water and it is given off screw the cap up, shake it, unscrew the  
dirty  
water?  
from the iron.  
cap and empty the tank. Repeat the action  
until the water is cleaned. We do not  
recommend the use of any additive to pour  
in the tank. Before ironing again spray  
some steam on a cloth until clean steam  
comes out.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
i500 SPARE PARTS LISTS  
ITEM  
NR  
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
4
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
4
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
DESCRIPTION  
AC004  
AST114  
CD332  
CD332/2  
CD338/1  
CD338/2  
CD338/3  
CD339/1  
BOX  
FAIRLEAD FOR HEATING ELEMENT  
HANDLE  
HEXAGONAL HEADED SCREW FOR HANDLE  
NUT FOR WAND SUPPORT  
WASHER FOR STICK SUPPORT  
WAND SUPPORT  
TANK  
CD343/110  
CD342  
CD346/35  
CD347  
CD347/7000  
CD348  
COPPER HEATING ELEMENT 1000 W - 120V  
TEFLON O-RING FOR THE HEATING ELEMENT  
PRESSURE SWITCH WITH RESET SET 2,5 BAR  
FAIRLEAD FOR CAP CONNECTION  
SOLENOID VALVE FAIRLEAD  
BULB THERMOSTAT 165°  
SCREW FOR BULB THERMOSTAT  
BIPOLAR SWITCH 16A  
CD348/1  
CD349  
CD350  
CD351  
CD353  
CD356  
CD360  
CD361  
CD363  
RED PILOT LIGHT 120/240V  
CONNECTOR  
4 POLE TERMINAL BOARD PA 21 TO FASTON  
MONOHOSE MT. 2,2 5X10  
FAIRLEAD STOP 6W-1  
FAIRLEAD STOP 6N3  
IRON PAD  
MALE SAFETY CAP 3/8  
O-RING FOR SAFETY CAP  
DYN SMALL FOOT  
STICK FOR MONOHOSE  
SPRING  
CLAMP FOR SPRING  
CD365/4  
CD366/6  
CD367  
CD368  
CD368/1  
CD368/2  
CD369  
FUNNEL DIAMETER 10 FOR ITEM 013  
ADJUSTABLE SOLENOID VALVE 120V  
GAUGE FOR 06-09/D  
MUSHROOM-SHAPED SMALL CAP FOR IRON REST  
ANTI-UNSCREWING SCREW 35x5  
HOSE CLAMP 10/12  
GV028/84/110  
CD374  
CD376  
CD377  
CD378  
CD378/1  
CD380/110  
CD382  
HOSE CLAMP 9/1  
WIRING 120V  
GLASS WOOL INSULATING  
3 WAY RECEPTACLE 1/4 CONICAL 1/4 FEMALE 1/8 FEMALE  
TECHNICAL DATA LABEL  
SMALL TECHNICAL DATA LABEL  
LOWER STAINLESS CHASSIS  
FRONT STAINLESS CHASSIS  
BACK STAINLESS CHASSIS  
STAINLESS UPPER BODY  
ANGLE CONNECTION  
CD384  
CD458  
CD458/1  
CD471  
CD473/1  
CD476  
CD477  
CD490  
CD492  
CV103  
INSTRUCTIONS MANUAL  
NUT 1/4 FOR SOLENOID VALVE 7000  
IRON PACKING  
CV114  
CV177  
KNOB 120V  
PLATE  
FS002/110  
FS003  
ADJUSTABLE THERMOSTAT  
THERMOSTAT WITH MANUAL RESET  
KORK HANDLE  
FS004  
FS005  
FS006  
FS007  
BRACKET  
IRON COVER  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ITEM  
NR  
1
1
1
5
3
2
1
2
3
1
1
1
1
1
1
1
1
1
1
2
2
2
1
4
1
2
1
1
1
0,03  
2
8
7
1
1
1
1
1
1
1
1
1
1
6
1
1
1
1
1
1
DESCRIPTION  
FS009  
FS011  
FS012  
FS012  
FS014  
FS015  
FS016  
FS017  
FS018  
FS019  
FS020  
FS021  
FS022  
FS023  
FS024  
FS025  
FS026  
FS027  
FS028  
FS030  
FS031  
FS032  
FS033  
FS035  
FS037  
FS038  
FS039  
FS041  
FS057  
FS058  
FS060  
WIRING 16AWG  
INSERTION  
SCREW FOR THERMOSTAT  
SCREW FOR THERMOSTAT  
SCREW FOR BACK HANDLE  
SCREW FOR MICRO SWITCH  
SCREW FOR MICRO SWITCH CASE  
SCREW FOR HANDLE FIXING  
SCREW FOR TERMINAL BLOCK STOP  
HANDLE COVER  
BACK HANDLE  
BUTTON HOLDER  
BUTTON CASE  
UPPER IRON BUTTON  
LOWER IRON BUTTON  
PLAQUE FOR BRACKET  
CABLE PRESS  
FRONT HANDLE HOLDER  
BACK HANDLE HOLDER  
SCREW CAPS  
BRASS WASHER  
BRASS SPACER  
MICRO SWITCH  
UNDER SCREW  
SPHERE FOR KNOB  
WASHER FOR HANDLE  
WASHER FOR KNOB  
FAIRLEAD FOR POWER CORD  
SPRING  
COATED  
WASHER  
NUT  
WASHER  
COPPER PIPE  
FEMALE QUICK RELEASE  
QUICK RELEASE  
L. JOINT  
L. JOINT  
GV025/23  
GV025/27  
GV025/51  
GV026/7  
GV026/9  
GV028/30  
GV028/31  
GV028/36  
GV028/38  
GV028/39  
GV028/40  
GV028/45  
GV028/52  
GV028/6  
GV669  
ILME FEMALE SOCKET GROUP  
ILME MALE SOCKET GROUP  
REMOVABLE COVER  
CABLE PRESS  
COVER WITH ROD  
SCREW  
L. JOINT  
BOX  
GV671  
INSTRUCTIONS MANUAL  
POWER CORD 110V  
TERMINAL BLOCK  
CERAMIC TERMINAL BOARD 120V  
MC016/110  
RIC003  
RIC003/2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
i500 PARTS DRAWING  
Download from Www.Somanuals.com. All Manuals Search And Download.  
i500 WIRING DIAGRAM  
Download from Www.Somanuals.com. All Manuals Search And Download.  
USER INSTRUCTIONS i500A/B  
Thank you for purchasing the Reliable™ i500A/B steam cleaner. Please  
follow the instructions carefully. With proper care and maintenance, your  
steamer will provide years of dependable service.  
1. Unscrew the security cap and fill the steamer with a maximum of 2  
Liters of water. If you have ordered the i500A with the nozzle and  
foot pedal, screw the nozzle into the steam fitting and plug in the 4-  
pin receptacle for the electronic foot pedal. If you have the ordered  
the i500B with steam gun connect the same way using the quick  
disconnect for the steam hose.  
2. Plug the steam generator into the main power supply.  
3. Switch on the steam generator by pressing the button "boiler" and  
the steam by pressing the "steam" button.  
4. Wait until the pressure reaches 3.5-bar (50 lbs). This will take  
approximately 15 minutes.  
5. Press the foot pedal or the (red) steam button on the steam gun and  
regulate the desired steam quantity by turning the valve handle  
situated behind the solenoid valve on the steam generator.  
6. If you notice a decrease in steam pressure when you first use the  
steamer, this is because the tank is full of air. In order to have plenty  
of steam (after you have depressed the foot pedal or steam gun)  
wait until the pressure goes back up to the maximum level before  
you begin.  
7. If during use the steam flow ceases and the low water button lights  
up, it means that there's no more water in the steam generator. In  
order to start steaming again, switch off the "boiler" button, slowly  
unscrew the security cap, verifying before unscrewing it completely  
that there is no more steam in the nozzle or steam gun. To verify  
this, just press the foot pedal or the red steam button situated on the  
gun. Take the plug off the steam generator and fill the steamer with  
water to the required level.  
IMPORTANT  
When you are finished using the boiler for the day, unscrew the fill cap one-  
turn on the unit to release the steam/air from the tank. This will eliminate the  
vacuum that may cause damage to the pressure gauge.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
i500A COMPONENTS  
COMPONENT LIST  
1.  
2.  
3.  
4.  
5.  
6.  
7.  
Safety cap  
Pressure gauge (manometer)  
Steam button  
Boiler button  
Low water light indicator  
Steam regulating knob  
Adjustable nozzle  
Download from Www.Somanuals.com. All Manuals Search And Download.  
i500B COMPONENTS  
COMPONENT LIST  
1. Safety cap  
2. Pressure gauge (manometer)  
3. Steam button  
4. Boiler button  
5. Low water light indicator  
6. Steam regulating knob  
7. Cord support  
8. Steam switch  
9. Steam gun  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CAUTION  
Never leave the steamer unattended when it's plugged in. Always  
pull the plug out before you fill it with water.  
Never remove the tank locking cap while the steamer is running and  
always check, before removing it, that no steam is coming out of the  
gun.  
The tank-locking cap must be replaced with original spare parts. DO  
NOT TIGHTEN THE CAP TOO MUCH AS IT WILL CAUSE THE  
PLASTIC TO CRACK. MAKE SURE IT IS "SNUG".  
The use of normal tap water is recommended for the i500. In order  
to clean the steam generator and remove mineral content, rinse it  
internally (every 15-20 Liters of water used or every month) with tap  
water.  
The guarantee does not cover mineral damages due to not rinsing  
the steam generator.  
Service: If you need to have your i500 serviced, please contact only  
authorized technical assistance centers (for further information  
please call 800-268-1649 or visit our web site at  
www.reliablecorporation.com).  
IMPORTANT  
When you are finished using the steamer for the day, unscrew the fill cap  
one-turn on the unit to release the steam/air from the tank. This will eliminate  
the vacuum that may cause damage to the pressure gauge.  
TECHNICAL DATA  
Full aluminium-plated heating element at 800W –120V  
Boiler power i500: 1000W  
Working pressure i500: 3,5 bar  
Tank nominal capacity of model i500: 2,5 Litres  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TROUBLESHOOTING  
PROBLEM  
EXPLANATION  
SOLUTION  
Does  
steam go  
out from  
It may happen that, while filling the In order to solve the problem, we suggest  
tank, some water overfills the cap using the machine as usual so that the  
and flows inside the boiler wetting insulating material dries up in about one  
the boiler? the insulating material  
hour through the heat of the machine. In  
case you still have this problem after one  
working hour, please contact the service  
centre.  
Does the  
nozzle or  
gun leak  
water  
1) While filling the tank you may 1) The problem will go on until the excess  
have poured too much water into it. water is emptied. Keep the steam button  
depressed until the water in the tank is at  
the correct level.  
mixed with  
steam?  
There is  
no steam  
coming out  
of the  
nozzle or  
gun?  
1) The steam knob (where  
supplied) might be closed  
1) Open the steam knob anticlockwise.  
2) Plug the 4-pin receptacle into the boiler.  
2) The foot pedal is not plugged in  
(i500B)  
3) After the boiler switch comes on, wait for  
10 minutes so the boiler produces steam.  
3) The boiler switch might be off  
4) The water might be used up.  
4) Fill it following the instructions carefully.  
Does the  
Some dirty might have gone into Fill the empty tank with 1 liter of water,  
steam leak the tank with the water and it is screw the cap up, shake it, unscrew the  
dirty  
water?  
given off from the iron.  
cap and empty the tank. Repeat the action  
until the water is cleaned. We do not  
recommend the use of any additive to pour  
in the tank. Before ironing again spray  
some steam on a cloth until clean steam  
comes out.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
i500A SPARE PARTS LISTS  
ITEM CODE  
AC003  
AST100  
CD332  
CD332/2  
CD338/1  
CD338/2  
CD338/3  
CD339/1  
CD343/110  
CD342  
CD346/35  
CD347  
CD347/7000  
CD348  
CD348/1  
CD349  
Q.TY  
1
1
1
2
1
3
1
1
1
1
1
1
1
1
2
2
1
1
5
1
2
1
1
4
1
1
1
1
6
4
1
1
1
3
1
1
1
1
1
1
5
1
8
7
1
1
1
1
1
1
1
1
6
1
1
1
0,26  
1
1
1
1
DESCRIPTION  
BOX  
PEDAL WITH CORD  
HANDLE  
HEXAGONAL HEADED SCREW FOR HANDLE  
NUT FOR WAND SUPPORT  
WASHER FOR STICK SUPPORT  
WAND SUPPORT  
TANK  
COPPER HEATING ELEMENT 1000 W - 120V  
TEFLON O-RING FOR THE HEATING ELEMENT  
PRESSURE SWITCH WITH RESET SET 2,5 BAR  
FAIRLEAD FOR CAP CONNECTION  
SOLENOID VALVE FAIRLEAD  
BULB THERMOSTAT 165°  
SCREW FOR BULB THERMOSTAT  
BIPOLAR SWITCH 16A  
CD350  
CD351  
CD353  
CD360  
RED PILOT LIGHT 120/240V  
CONNECTOR  
4 POLE TERMINAL BOARD PA 21 TO FASTON  
FAIRLEAD STOP 6W-1  
CD361  
FAIRLEAD STOP 6N3  
MALE SAFETY CAP 3/8  
O-RING FOR SAFETY CAP  
DYN SMALL FOOT  
CD365/4  
CD366/6  
CD367  
CD368  
CD369  
GV028/84/110  
CD374  
CD376  
CD377  
CD380/110  
CD382  
CD384  
CD458  
CD471  
CD473/1  
CD476  
CD477  
CD492  
CV103  
STICK FOR MONOHOSE  
FUNNEL DIAMETER 10 FOR ITEM 013  
ADJUSTABLE SOLENOID VALVE 120V  
GAUGE FOR 06-09/D  
MUSHROOM-SHAPED SMALL CAP FOR IRON REST  
ANTI-UNSCREWING SCREW 35x5  
WIRING 120V  
GLASS WOOL INSULATING  
3 WAY RECEPTACLE CONICAL 1/4 FEMALE 1/8 FEMALE  
TECHNICAL DATA LABEL  
LOWER STAINLESS CHASSIS  
FRONT STAINLESS CHASSIS  
BACK STAINLESS CHASSIS  
STAINLESS UPPER BODY  
INSTRUCTIONS MANUAL  
NUT 1/4 FOR SOLENOID VALVE 7000  
SCREW FOR THERMOSTAT  
SPHERE FOR KNOB  
FS012  
FS037  
GV025/23  
GV025/27  
GV025/51  
GV028/30  
GV028/31  
GV028/36  
GV028/38  
GV028/39  
GV028/40  
GV028/45  
GV028/52  
GV028/61  
GV028/62  
GV028/63  
GV028/64  
GV028/65  
MC016/110  
MC099  
NUT  
WASHER  
COPPER PIPE  
L. JOINT  
L. JOINT  
ILME FEMALE SOCKET GROUP  
ILME MALE SOCKET GROUP  
REMOVABLE COVER  
CABLE PRESS  
COVER WITH ROD  
SCREW  
METAL POINT FOR STEAMER  
JOINT FOR STEAMER  
JOINT 1/8"F FOR STEAMER  
GLASS WOOL INSULATING  
COPPER PIPE  
POWER CORD 110V  
BOX  
RIC003/2  
CERAMIC TERMINAL BLOCK 110V  
Download from Www.Somanuals.com. All Manuals Search And Download.  
i500A PARTS DRAWING  
Download from Www.Somanuals.com. All Manuals Search And Download.  
i500B SPARE PARTS LISTS  
ITEM CODE  
AC003  
CD332  
CD332/2  
CD338/1  
CD338/2  
CD338/3  
CD339/1  
CD343/110  
CD342  
CD346/35  
CD347  
CD347/7000  
CD348  
CD348/1  
CD349  
Q.TY  
1
1
2
1
3
1
1
1
1
1
1
1
1
2
2
1
1
5
1
1
2
1
1
4
1
1
1
1
6
4
2
1
1
1
3
1
1
1
1
1
1
1
1
5
1
8
7
1
1
1
1
1
1
1
1
1
6
1
1
DESCRIPTION  
BOX  
HANDLE  
HEXAGONAL HEADED SCREW FOR HANDLE  
NUT FOR WAND SUPPORT  
WASHER FOR STICK SUPPORT  
WAND SUPPORT  
TANK  
COPPER HEATING ELEMENT 1000 W - 120V  
TEFLON O-RING FOR THE HEATING ELEMENT  
PRESSURE SWITCH WITH RESET SET 2,5 BAR  
FAIRLEAD FOR CAP CONNECTION  
SOLENOID VALVE FAIRLEAD  
BULB THERMOSTAT 165°  
SCREW FOR BULB THERMOSTAT  
BIPOLAR SWITCH 16A  
CD350  
CD351  
CD353  
CD356/6  
CD360  
RED PILOT LIGHT 120/240V  
CONNECTOR  
4 POLE TERMINAL BOARD PA 21 TO FASTON  
COATED HOSE 5X10  
FAIRLEAD STOP 6W-1  
FAIRLEAD STOP 6N3  
MALE SAFETY CAP 3/8  
O-RING FOR SAFETY CAP  
DYN SMALL FOOT  
CD361  
CD365/4  
CD366/6  
CD367  
CD368  
CD369  
GV028/84/110  
CD374  
CD376  
CD377  
CD378  
CD380/110  
CD382  
CD384  
CD458  
CD471  
CD473/1  
CD476  
CD477  
CD492  
CV043  
CV103  
CV114  
FS012  
FS037  
GV025/23  
GV025/27  
GV025/51  
GV026/9  
GV028/30  
GV028/31  
GV028/36  
GV028/38  
GV028/39  
GV028/40  
GV028/45  
GV028/52  
MC016/110  
RIC003/2  
STICK FOR MONOHOSE  
FUNNEL DIAMETER 10 FOR ITEM 013  
ADJUSTABLE SOLENOID VALVE 120V  
GAUGE FOR 06-09/D  
MUSHROOM-SHAPED SMALL CAP FOR IRON REST  
ANTI-UNSCREWING SCREW 35x5  
HOSE CLAMP  
WIRING 120V  
GLASS WOOL INSULATING  
3 WAY RECEPTACLE CONICAL 1/4 FEMALE 1/8 FEMALE  
TECHNICAL DATA LABEL  
LOWER STAINLESS CHASSIS  
FRONT STAINLESS CHASSIS  
BACK STAINLESS CHASSIS  
STAINLESS UPPER BODY  
INSTRUCTIONS MANUAL  
STEAMER WITH ROUND NOZZLE  
NUT 1/4 FOR SOLENOID VALVE 7000  
IRON PACKING  
SCREW FOR THERMOSTAT  
SPHERE FOR KNOB  
NUT  
WASHER  
COPPER PIPE  
QUICK RELEASE  
L. JOINT  
L. JOINT  
ILME FEMALE SOCKET GROUP  
ILME MALE SOCKET GROUP  
REMOVABLE COVER  
CABLE PRESS  
COVER WITH ROD  
SCREW  
POWER CORD 110V  
CERAMIC TERMINAL BLOCK 110V  
Download from Www.Somanuals.com. All Manuals Search And Download.  
i500B PARTS DRAWING  
Download from Www.Somanuals.com. All Manuals Search And Download.  
i500A/B WIRING DIAGRAM  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WATER LEVEL STICK  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

RCA CRT Television 36V550T User Guide
RedMax Edger HEZ2450S User Guide
Rotel Speaker System RMZ 955 User Guide
Rotel Stereo Amplifier RA 840B User Guide
Runco Projector CL 510 User Guide
Ryobi Laser Level ELL1001 User Guide
Samsung Air Conditioner AS070VE User Guide
Samsung Car Video System 2493HM User Guide
Sanyo Air Conditioner C4232 User Guide
Sears Air Compressor 919153011 User Guide