Regency Indoor Fireplace U32S LP5 User Guide

Owners &  
Installation Manual  
U32 SunriseGas Insert  
MODELS: U32S-NG5 Natural Gas  
U32S-LP5 Propane  
www.regency-re.com  
WARNING:  
FOR YOUR SAFETY  
Improper installation, adjustment, alteration, service or What to do if you smell gas:  
maintenance can cause injury or property damage. Refer to  
this manual. For assistance or additional information consult  
an authorized installer, service agency or the gas supplier.  
Do not try to light any appliance  
Do not touch any electrical switch:  
do not use any phone in your  
building.  
Immediately call your gas supplier  
from a neighbour's phone. Follow  
the gas supplier's instructions.  
If you cannot reach your gas  
supplier, call the re department.  
FOR YOUR SAFETY  
Do not store or use gasoline or other ammable vapours and  
liquids in the vicinity of this or any other appliance.  
Installation and service must be performed by an authorized  
installer, service agency or the gas supplier.  
Tested by:  
Installer: Please complete the details on the back cover  
and leave this manual with the homeowner.  
Homeowner: Please keep these instructions for future reference.  
918-788  
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4  
11/03/08  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TABLE OF CONTENTS  
OPERATING INSTRUCTIONS  
SAFETY LABEL  
Operating Instructions ................................................22  
Lighting Procedure ......................................................22  
Shutdown Procedure...................................................22  
First Fire ......................................................................22  
Automatic Convection Fan Operation..........................22  
Normal Operating Sounds Of Gas Appliances............22  
Maintenance Instructions............................................23  
Copy Of Lighting Instruction Plate...............................23  
Safety Label...................................................................4  
REQUIREMENTS  
MA Code - CO Detector.................................................5  
UNIT DIMENSIONS  
MAINTENANCE  
Unit Dimensions..............................................................6  
General Vent Maintenance..........................................24  
Glass Gasket...............................................................24  
Door Glass ..................................................................24  
Fan Maintenance.........................................................25  
Fan Removal...............................................................25  
Valve Assembly Replacement .....................................28  
INSTALLATION  
Important Message ......................................................7  
For Your Safety..............................................................7  
Specications ................................................................7  
Gas Pressure Testing ....................................................7  
Installation Into A Solid Fuel Burning Fireplace Or  
PARTS LIST  
Main Assembly ............................................................30  
Burner Assembly .........................................................31  
Faceplate and Door Frame..........................................32  
Factory Built Fireplace...................................................7  
Before You Start ............................................................7  
Installation Checklist......................................................8  
Manufactured Mobile Home Additional Requirements ..8  
Materials Required ........................................................8  
Minimum Fireplace Dimensions ....................................8  
Clearances To Combustibles.........................................8  
Combustible Mantel Clearances....................................9  
Gas Connection ............................................................9  
Venting...........................................................................9  
Flue Liner Installation ..................................................10  
Gas Pipe Pressure Testing..........................................10  
Gas Insert Aeration System.........................................10  
Conversion from NG to LP ........................................11  
Optional Wall Thermostat ...........................................14  
Optional Remote Control ............................................14  
Final Check..................................................................14  
Wiring Diagrams..........................................................15  
Glass Crystal or Ceramic Stone Installation.................17  
Standard Flush Door ...................................................18  
Faceplate and Door Frame Installation .......................19  
Optional Hearth Trim Installation.................................21  
WARRANTY  
The Warranty: Limited Lifetime ...................................35  
U32S-5 FPI Direct Vent Gas Insert  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
SAFETY LABEL  
This is a copy of the label that accompanies each U32S-5 Gas Insert. NOTE: FPI units are constantly being improved. Check the label  
We have printed a copy of the contents here for your review. The safety on the unit and if there is a difference, the label on the unit is the  
label is located on a plate inside the base of the unit visible when the correct one.  
bottom louver is opened.  
For the State of Massachusetts, installation and repair must be done by a plumber or gastter licensed in the Commonwealth of  
Massachusetts.  
For the State of Massachusetts, exible connectors shall not exceed 36 inches in length.  
For the State of Massachusetts, the appliances individual manual shut-off must be a t-handle type valve.  
The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm with  
battery back up in the same room where the gas appliance is installed.  
4
U32S-5 FPI Direct Vent Gas Insert  
Download from Www.Somanuals.com. All Manuals Search And Download.  
REQUIREMENTS  
MA Code - CO Detector  
(for the State of Massachusetts only)  
5.08: Modifications to NFPA-54, Chapter 10  
(2) Revise 10.8.3 by adding the following additional requirements:  
(a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for  
residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than  
seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall  
be satisfied:  
1. INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fueled  
equipment, the installing plumber or gasfitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is  
installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gasfitter shall observe that a battery  
operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure  
served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of  
qualified licensed professionals for the installation of hard wired carbon monoxide detectors  
a. In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon  
monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.  
b. In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of  
thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon  
monoxide detector with an alarm shall be installed.  
2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above provisions  
shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified.  
3. SIGNAGE. A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight  
(8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The  
sign shall read, in print size no less than one-half (1/2) inch in size, "GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL  
OBSTRUCTIONS".  
4. INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation  
unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR  
5.08(2)(a)1 through 4.  
(b) EXEMPTIONS: The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4:  
1. The equipment listed in Chapter 10 entitled "Equipment Not Required To Be Vented" in the most current edition of NFPA 54 as adopted by  
the Board; and  
2. Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building or  
structure used in whole or in part for residential purposes.  
(c) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM PROVIDED. When the manufacturer of Product  
Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the  
instructions provided by the manufacturer for installation of the equipment and the venting system shall include:  
1. Detailed instructions for the installation of the venting system design or the venting system components; and  
2. A complete parts list for the venting system design or venting system.  
(d) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of a  
Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases, but identifies  
"special venting systems", the following requirements shall be satisfied by the manufacturer:  
1. The referenced "special venting system" instructions shall be included with the appliance or equipment installation instructions; and  
2. The "special venting systems" shall be Product Approved by the Board, and the instructions for that system shall include a parts list and  
detailed installation instructions.  
(e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions,  
all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of  
the installation.  
U32S-5 FPI Direct Vent Gas Insert  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
UNIT DIMENSIONS  
6
U32S-5 FPI Direct Vent Gas Insert  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
General Safety Information  
GAS PRESSURE  
TESTING  
IMPORTANT MESSAGE  
SAVE THESE  
1) The appliance installation must conform  
with local codes or in the absence of local  
codes, with CAN/CGAB149 (in Canada) or  
the National Fuel Gas CodeANSI Z223.1 in  
theU.S.A.Thisapplianceshouldbeinstalled  
by a qualied gas tter technician only.  
INSTRUCTIONS  
The appliance must be isolated from the gas  
supply piping system by closing its individual  
manual shut off valve during any pressure  
testing of the gas supply piping system at test  
pressures equal to or less than  
The FPI Gas Insert must be installed in  
accordance with these instructions. Carefully  
read all the instructions in this manual rst.  
Consultthebuildingauthorityhavingjurisdiction  
todeterminetheneedforapermitpriortostarting  
the installation.  
2) Installation and repair should be done  
by a qualied service person.  
1/2 psig. (3.45 kPa).  
3) The appliance should be inspected before  
use and at least annually by a professional  
service person. More frequent cleaning  
may be required due to excessive lint from  
carpeting,beddingmaterial,animalhair,etc.  
It is imperative that control compartments,  
burners and circulating air passageways of  
the appliance be kept clean.  
NOTE: Failure to follow the instructions could  
cause a malfunction of the heater which could  
result in death, serious bodily injury, and/or  
property damage. Failure to follow these  
instructions may also void your re insurance  
and/or warranty.  
INSTALLATION INTO A  
SOLID FUEL BURNING  
FIREPLACE OR  
FACTORY BUILT  
FIREPLACE  
4) See general construction and assembly  
instructions. This appliance may only be  
installed in a vented, noncombustible  
replace.  
FOR YOUR SAFETY  
The U32S Gas Insert has been tested and  
approvedtobeventedintoanymasonryreplace  
or approved solid fuel burning factory built  
replace that will allow the insert to physically  
t into the rebox. Refer to "Minimum Fireplace  
Dimensions" section for minimum replace  
clearances.  
Thisappliancerequiresairforpropercombustion.  
Always provide adequate combustion and  
ventilation air. Follow instructions and  
information in CAN/CGA B149 (in Canada) or  
theNationalFuelGasCodeANSIZ223.1(inthe  
USA), regarding requirements for combustion  
and ventilation air.  
5) This appliance is Listed for bedroom  
installationswhenusedwithaListedMillivolt  
Thermostat. Some areas may have further  
requirements, check local codes before  
installation.  
If the factory built replace* height is too low for  
your Insert, you may remove the smoke bafe  
plate, damper, refractory (rebricks), glass  
doors, screen rails, screen mesh and log grates  
from the factory built replace as long as these  
items are saved and are reinstalled in the event  
that the Insert is removed.  
6) Always connect this insert to a vent system  
venting to the outside of the building  
envelope. Never vent to another room or  
inside a building. Make sure that the vent  
is properly sized and is of adequate height  
to provide the proper draft.  
SPECIFICATIONS  
At pressures over 1/2 psig, the pipe to the unit  
must be disconnected.  
Smoke shelves, shields and bafes may be  
removed if attached by mechanical fasteners.  
If any part is removed it must not weaken the  
structural integrity of the factory built replace.  
7) Inspect the venting system annually for  
Gas Input Capacity:  
blockage and any signs of deterioration.  
Natural Gas 24,500 Btu/h  
8) Any glass removed for servicing must be  
Propane  
20,500 Btu/h  
replaced prior to operating the appliance.  
NOTE: Any alterations made to the listed solid  
fuel burning factory built replace may void the  
listing of the replace.  
Min. Input  
Natural Gas 16,500 Btu/h  
Propane 17,000 Btu/h  
9) To prevent injury, do not allow anyone who  
is unfamiliar with the operation to use the  
replace.  
*Check with your local inspector before  
commencing with this installation.  
10) Due to high temperatures, the appliance  
should be located out of high trafc areas  
and away from furniture and draperies.  
Children and adults should be alerted to  
the hazards of high surface temperatures,  
especially the replace glass and gold  
trims, and should stay away to avoid burns  
or clothing ignition. Young children should  
be carefully supervised when they are in  
the same room as the appliance. Clothing  
or other ammable material should not be  
placed on or near the appliance.  
Fuels: Approved for use with both natural gas,  
and propane. Approved as is for use at 0' to  
4,500' (0-1370m).  
Installer must mechanically attach the supplied  
label to the inside of the rebox of the replace  
into which the gas replace insert is installed.  
Electrical: 120V A.C. system.  
"WARNING:Thisreplacehasbeenconverted  
for use with a gas replace insert only and  
cannot be used for burning wood or solid fuels  
unless all original parts have been replaced,  
and the replace re-approved by the authority  
having jurisdiction."  
Circulation Fan: Variable speed, 110 CFM.  
Vent System: 3" co-linear aluminum ex.  
The efciency rating of the appliance is a  
product thermal efciency rating determined  
under continuous operating conditions and  
was determined independent of any installed  
system.  
Emissions from burning wood or gas could  
contain chemicals known to the State of  
California to cause cancer, birth defects or  
other reproductive harm.  
BEFORE YOU START  
Safe installation and operation of this appliance  
requires common sense, however, we are  
required by the Canadian Safety Standards  
and ANSI Standards to make you aware of  
the following:  
U32S-5 FPI Direct Vent Gas Insert  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
INSTALLATION  
CHECKLIST  
CLEARANCES TO  
COMBUSTIBLES  
MANUFACTURED  
MOBILE HOME  
ADDITIONAL  
Before installing vent system ensure that the  
damper plate is open and secure to prevent the  
damper plate from falling down and crushing  
the liner.  
Minimum Clearances to Combustibles  
REQUIREMENTS  
From Unit  
Sides  
A
B
C
10" / 255 mm  
47.5" / 1205 mm  
13" / 330mm  
1) Ensure that structural members are not cut  
Ceiling  
Mantel  
or weakened during installation.  
The FPI Gas Insert is installed as listed.  
1) Checkallclearancestocombustibles,(Refer  
tosections"MinimumFireplaceDimensions  
and Clearances to Combustibles)  
2) Ensure proper grounding using the #8  
Max. Mantle Depth  
G
12" / 305 mm  
ground lug provided.  
Min. Alcove Width  
Max. Alcove Depth  
K
L
48" / 1220 mm  
36" / 915 mm  
3) Appliance must be anchored to the oor  
2) Make the gas connection. (Refer to section  
with the supplied anchoring methods.  
"Gas Connection")  
3) Install the 3" flue liner to the sliding  
connectorplate.(Refertosection"FlueLiner  
Installation.")  
MATERIALS REQUIRED  
Noelectricalpowersupplyisrequiredforthegas  
control to operate. A120 VoltAC power cord is  
hooked up to the fan. Plug the 3 wire cord into  
a suitable receptacle. Do not cut the ground  
terminaloffunderanycircumstances. When  
connectedwith120volts,theappliancemustbe  
electrically grounded in accordance with local  
codes,currentversionofCSAC22.1(inCanada)  
orintheabsenceoflocalcodes,withtheNational  
Electrical Code ANSI/NFPA 70-1987.  
4) Slide the unit half way into the replace.  
B
5) Pull the vent connector plate through the  
taperedbracketsandfastentothefrontplate.  
Refer to section "Flue Liner Installation.")  
G
L
6) Slide the unit fully into the replace.  
A
7) Test gas pressure (Refer to section "Gas  
Pipe Pressure Testing"). Check aeration  
system(Refertosection"GasInsertAeration  
System").  
NOTE: This unit is equipped with a heat  
sensor thermodisc which will  
prevent the blower from operating  
until the unit reaches the correct  
temperature.  
C
8) Installstandardandoptionalfeatures. Refer  
K
to the following sections:  
MINIMUM FIREPLACE  
DIMENSIONS  
a. LP Conversion Kit  
b. Glass Crystals  
c. Optional Ceramic Spa Stones  
d. Standard Flush Door  
e. Contemporary Faceplate & Door Frame  
f. Wall Thermostat  
Theminimumreplaceclearances&dimensions  
for the FPI gas insert are shown in the following  
diagrams:  
g. Remote Control  
9) Finalcheck:Beforeleavingthisunitwiththe  
customer, the installer must ensure that the  
appliance is ring correctly. This includes:  
A
B
a) Clocking the appliance to ensure the  
correct ring rate.  
b) Adjusting the primary air, if required, to  
ensure that the ame does not carbon.  
See "Gas Insert Aeration System"  
section.  
C
D
c) Ensuring that the appliance is venting  
correctly.  
E
Max. Lentil  
Bar Depth  
A
Height  
Depth  
Width  
(rear)  
D
Width  
(front)  
E
B
C
9"  
22"  
14"  
22-1/2"  
26-1/2"  
8
U32S-5 FPI Direct Vent Gas Insert  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
GAS CONNECTION  
COMBUSTIBLE MANTEL  
CLEARANCES  
GAS CONNECTION WARNING:  
Only persons licensed to work  
with gas piping may make the  
necessary gas connections  
to this appliance.  
G
0
12 10  
8
6
4
2
18  
16  
12" Mantel  
47”  
1) If the appliance is to be installed into an  
existing chimney system, thoroughly clean  
the masonry or factory built replace.  
3-1/2"  
Mantel  
(1194mm) 14  
to ceiling  
12  
10  
8
2) Theapplianceisprovidedwithanopeningon  
thelefthandsideofthecontrolcompartment.  
A3/8"NPTgassupplypipemustbebrought  
near this inlet hole.  
17"  
6
13"  
3) Locate the center point where the vent  
will pass through the chimney above the  
appliance. Move the appliance into the  
exact location where it is to be installed.  
Ensure that the Insert is level.  
4
2
0
Alternate Approved Caps  
20“  
to floor  
Top of  
Unit  
46dva-VC Vertical Termination Cap  
46dva-VCH High Wind Cap  
46dva-GK 3" Co-linear Adaptor with ashing  
C
L
Side View  
In areas of consistently high winds, we  
recommend using the Simpson Dura-Vent  
System (46dva-GK adapter and 46dva-VCH  
high-wind cap).  
Due to the extreme heat this replace emits,  
the mantel clearances are critical.  
Gas  
Inlet  
The Air Intake pipe must be attached to the  
inlet air collar of the termination cap.  
Note: A non-combustible mantel may be  
installed at a lower height if the  
framing is made of metal studs  
covered with a non-combustible  
board.  
VENTING  
Mantelcanbeinstalledanywhereinshadedarea  
or higher using the above scale.  
THE APPLIANCE MUST NOT BE  
CONNECTED TO A  
Note: Ensure the paint that is used  
on the mantel and the facing is  
"heat resistant" or the paint may  
discolour.  
CHIMNEY FLUE SERVING A  
SEPARATE SOLID FUEL  
BURNING APPLIANCE.  
This appliance is designed to be attached to  
two 3" (76mm) co-linear aluminium ex running  
the full length of the chimney. The ue length  
must be a minimum length of 8 ' (2.44m) and  
a maximum of 35' (10.7m). See chart below for  
minimumdistancesfromroof.Periodicallycheck  
that the vent is unrestricted.  
Masonry chimneys may take various contours  
which the exible liner will accommodate.  
However,keeptheexiblelinerasstraightas  
possible, avoid unnecessary bending.  
TheAir Intake pipe must be attached to the inlet  
air collar of the termination cap.  
Part #  
Description  
948-305  
946-529  
3" Flex - 35 ft.  
Co-linear DV Vertical  
Termination Cap  
U32S-5 FPI Direct Vent Gas Insert  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
5) The pressure check should be carried out  
withtheunitburningandthesettingshould  
be within the limits specied on the safety  
label.  
FLUE LINER  
INSTALLATION  
6) When nished reading manometer, turn  
off the gas valve, disconnect the hose and  
tighten the screw (clockwise) with a 1/8"  
at screwdriver. Note: Screw should be  
snug, but do not over tighten.  
1) Cut the ex liner as required.  
2) Mark the end of one liner to indicate  
Inlet.  
3) Connect the other end of the above liner to  
theinletsideoftheterminationadaptor,seal  
connection with high temperature silicone.  
Secure with gear clamp.  
GAS INSERT  
AERATION SYSTEM  
4) Connect the 2nd liner to the exhaust side  
of the adaptor, seal connection with high  
temperature silicone. Secure with gear  
clamp.  
Theburneraerationisfactorysetbutmayneed  
adjustingduetoeitherthelocalgassuppplyor  
altitude. Open the air shutter for a blue ame  
or close for a yellow ame.  
Be careful not to damage thermal insula-  
tion when sliding on vent connector plate.  
This could cause blockage.  
5) Install ashing.  
The burner assembly will need to be removed  
in order to adjust burner aeration if required.  
See steps 1-4 in 'Conversion from NG to LP.  
Minimum Air shutter Opening  
Glass  
Crystals  
Ceramic  
Stones  
Natural Gas  
Propane  
3/8"  
1/2"  
1/8"  
3/8"  
CAUTION: Carbon will be produced if air  
shutter is closed too much.  
GAS PIPE  
PRESSURE TESTING  
Note: Any damage due to carboning  
resulting from setting the aeration  
controls improperlyisNOTcoveredunder  
warranty.  
The appliance must be isolated from the gas  
supply piping system by closing its individual  
manual shut-off valve during any pressure  
testing of the gas supply piping system at test  
pressures equal to or less than 1/2 psig. (3.45  
kPa). Disconnectpipingfromvalveatpressures  
over 1/2 psig.  
Note: Aeration Adjustment should only  
be performed by an authorized FPI  
Installer at the time of installation  
or service.  
6) Insert both liners into chimney, passing  
through the damper opening.  
7) Install termination cap.  
8) Connect the marked end of the liner to  
the inlet collar of the vent connector plate  
marked with an "I", seal connection with  
high temperature silicone. Secure with gear  
clamp.  
The manifold pressure is controlled by a  
regulator built into the gas control, and should  
be checked at the pressure test point.  
Note: To properly check gas pressure, both  
inlet and manifold pressures should  
becheckedusingthevalvepressure  
ports on the valve.  
1) Make sure the valve is in the "OFF"  
position.  
9) Connect the 2nd liner to the exhaust collar  
marked with an "E", seal connection with  
high temperature silicone. Secure with gear  
clamp.  
NOTES:  
2) Loosen the "IN" and/or "OUT" pressure  
tap(s), turning counterclockwise with a 1/8"  
wide at screwdriver.  
1) Final gas connection should be made after  
unit is in place to avoid damage to line when  
pushing the unit into position.  
3) Attach manometer to "IN" and/or "OUT"  
pressure tap(s) using a 5/16" ID hose.  
2) Mill-pac may be used instead of high  
temperature silicone and screws may be  
used instead of gear clamps at connections  
of liner to inlet and vent collars.  
4) Light the pilot and turn the valve to "ON"  
position.  
10  
U32S-5 FPI Direct Vent Gas Insert  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
CONVERSION KIT # 434-969 FROM NG TO LP  
U32S-5 using SIT 820 NOVA Gas Valve  
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER  
IF IN DOUBT DO NOT DO THIS CONVERSION !!  
b) Swing the door out 45 degrees from  
the bottom and lift up and out.  
Each Kit contains one LP  
Conversion Kit and one DC  
Sparker Kit.  
3) Remove the burner by undoing the 2  
LP Conversion Kit Contains:  
screws as shown below.  
Qty. Part #  
Description  
1
1
904-163  
918-590  
Burner Orifice #54  
Decal "Converted to  
LPG"  
1
1
1
908-528  
904-529  
910-037  
Red "LPG" label  
5/32" Allen Key  
LPG Injector  
Lift up from the back.  
(Pilot Orifice)  
1
918-480  
Instruction Sheet  
DC Sparker Kit Contains:  
Qty. Part # Description  
Burner  
1
1
1
1
1
820-475  
820-476  
904-153  
904-330  
904-438  
Bracket DC Sparker  
Bracket DC Sparker  
Washer #8 External Star  
Nut 8-32 Hex  
Plug Nylon 0.750 Hole,  
Black (for H25 only)  
Bushing Split Plastic  
0.500 in.  
Screw 8-32 x 3/4 Pan  
Head  
Screw #8 x 1/2 Type  
"B", Black Oxide  
Spark Generator  
Battery Holder  
6) Remove burner orifice with a 1/2" wrench  
1
1
2
1
1
1
904-531  
904-543  
904-553  
910-073  
910-074  
910-078  
and discard.  
4) After screws have been removed,  
slide the burner to the left, then lift out  
carefully.  
Spark Generator  
Switch C/W Wire  
Battery Size AA  
Energizer En91  
2
1
910-199  
910-903  
Clip Wire Holder  
Wire Fan To Power Cord  
Ground 30 in.  
904-781  
904-782  
Velcro Hook, Black  
Velcro Hook, Black  
5) Remove the base cover by lifting up  
Burner Orifice  
from the back, then maneover it out.  
1) Turn off the gas supply.  
7) Install the new LP burner orifice stamped  
#54 and tighten.  
2) Remove the glass door.  
8) Remove the pilot shield by removing the  
a) Release the two hooks from the  
2 screws as shown below.  
bottom of the glass door.  
Base Cover  
U32S-5 FPI Direct Vent Gas Insert  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
15) Insert a 5/32” or 4mm Allen wrench into  
the hexagonal key-way of the screw  
(Fig. 2), rotate it counter-clockwise until  
it is free and extract it.  
WARNING!  
Do not overtighten the screw.  
Recommended to grip  
the wrench by the short side.  
19) Verify that if the conversion is from  
NG to LPG, the screw must be re-  
assembled with the red o-ring visible  
(Fig. 5).  
Pilot Cap  
9) Pull off the pilot cap to expose the pilot  
orifice.  
LPG Configuration  
Red o-ring visible  
Fig.5  
20) Re-assemble the black protection cap  
Fig.2  
(Fig. 6).  
16) Check that the screw is clean and if  
10) Unscrew the pilot orifice with the  
supplied allen key and replace it with the  
LP pilot orifice and re-install the pilot cap  
and the pilot shield.  
necessary remove dirt.  
17) Flip the screw (Fig. 3).  
Fig.6  
WARNING!  
Also check that the pilot and  
main burner injectors  
are appropriate for the gas type.  
11) Re-install base cover.  
21) See DC Sparker installation in the  
Fig.3  
instruction manual.  
12) Re-install the burner.  
22) Attach the label "This unit has been  
converted to LPG" near or on top of the  
serial # decal.  
NOTE: Before re-installing the burner,  
ensure the LP areation setting is set  
at 1/2" min. when using glass crystals  
and 1/8" min. when using ceramic  
stones.  
18) Using the Allen wrench as shown in  
Fig.4, rotate the screw clockwise until  
snug, do not overtighten.  
23) Replace yellow "NG" label with red  
"LPG" label.  
13) Turn control knob to the “OFF” position.  
24) Check for gas leaks.  
14) Remove the black protection cap by  
hand from the high-low knob (Fig.1).  
25) Check inlet and outlet pressures.  
26) Reverse Step 2.  
27) Check operation of flame control.  
Installer Notice:  
Fig.4  
These instructions must be left  
with the appliance.  
Fig.1  
12  
U32S-5 FPI Direct Vent Gas Insert  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
11) Install the supplied battery into the DC  
Sparker Box by opening the battery  
compartment.  
6) Connect one end of the supplied green  
ground wire to the lug with the nut and  
washer from the kit.  
Installation of the DC Sparker  
1) Locate the Piezo Ignitor situated at the  
NOTE: The battery in the DC Sparker  
Box will need to be replaced annually.  
side of valve.  
Ground  
wire from  
kit  
Battery  
Compartment  
Piezo ignitor  
2) Remove the Piezo Ignitor by unscrewing  
the nut at the back of the mounting  
bracket.  
7) Install the 1/2" bushing to the heat  
shield.  
12) Mount the heat shield to the DC Sparker.  
Secure into place with the velcro, which  
is provided in the kit.  
Ignitor  
Wire  
Piezo  
Ignitor  
8) Run the other end of the ground wire  
and DC spark generator wires through  
the bushing on the heat shield.  
3) Disconnect the ignitor wire from the  
Piezo Ignitor and connect it to the DC  
Sparker.  
13) Find a location which is not too hot and is  
easy to reach for changing the battery.  
DC  
Sparker  
Heat Shield  
Note: It should be kept away from the  
chain.  
Chain  
Ignitor  
Wire  
4) Connect the DC spark generator wires  
to the SIT Valve with the screw, which is  
provided in the kit.  
9) Plug the DC spark generator wires to the  
DC Sparker.  
14) Tie up the loose wire with the wire clip.  
5) Locate the ground lug at the receptical  
10) Connect the ground wire to the DC  
box, left of the unit.  
Sparker mounting bracket.  
U32S-5 FPI Direct Vent Gas Insert  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
OPTIONAL WALL THERMOSTAT  
FINAL CHECK  
A wall thermostat may be installed if desired, follow the wiring diagram  
below. FPI offers an optional programmable thermostat but any 250-  
750 millivolt rated non-anticipator type thermostat that is CSA, ULC or  
UL approved may be used.  
Before leaving this unit with the customer, the installer must ensure that  
the appliance is ring correctly. This includes:  
1) Clocking the appliance to ensure the correct ring rate (rate noted  
on label) at 15 minutes.  
CAUTION  
Do not connect the millivolt wall thermostat wires  
to the 120V wires.  
2) If required, adjusting the primary air to ensure that the ame does  
not carbon. First allow the unit to burn for 15 min. to stabilize.  
Thermostat Wire Table  
3) Check for proper draft.  
Recommended Maximum Lead Length  
(Two-Wire) When Using Wall  
Thermostat (CP-2 System)  
CAUTION  
Wire Size  
Max. Length  
Any alteration to the product that causes sooting  
or carboning that results in damage to the exterior  
facia is not the responsibility of the manufacturer.  
14 GA.  
16 GA.  
18 GA.  
20 GA.  
22 GA.  
50 Ft.  
32 Ft.  
20 Ft.  
12 Ft.  
9 Ft.  
OPTIONAL REMOTE CONTROL  
Use the FPI Remote Control Kit approved for this unit. Use of other  
systems may void your warranty.  
The remote control kit comes with a hand held transmitter, a receiver and  
a wall mounting plate.  
1) Choose a convenient location on the wall to install the receiver and  
the receptacle box (protection from extreme heat is very important).  
Run wires from the replace to that location. Use Thermostat Wire  
Table.  
2) Connect the wires as per the wiring diagrams in this manual.  
CAUTION  
Do not connect the millivolt  
remote control  
the 120V wires.  
3) Install 3 AAA alkaline batteries in transmitter and 4 AA alkaline bat-  
teries in the receiver. Install the receiver and its cover in the wall.  
Switch the remote receiver to "remote" mode. The remote control is  
now ready for operation.  
14  
U32S-5 FPI Direct Vent Gas Insert  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
WIRING DIAGRAMS  
This heater does not require a 120V A.C. supply for operation. In case of a power failure, the burner switch and the optional remote control/  
thermostat will continue to operate. However, a 120V A.C. power supply is needed for the fan/blower operation.  
Caution: Ensure that the wires do not touch any hot surfaces and are away from sharp edges.  
For NATURAL GAS Units and Units NOT Equipped with DC Spark Boxes  
Green  
Fan  
Ground  
Neutral  
Ground  
Live  
120V AC  
ON  
OFF  
Black  
Red Black  
Pilot  
Assembly  
Rotary Speed  
Control  
Minimum Convection  
Air Temp. Switch  
To  
Thermocouple IN  
Thermocouple  
In  
Piezo  
Ignitor  
Black  
Red  
ON  
Gas  
In  
Burner  
F
F
O
White  
Brown  
OFF  
"S.I.T" Valve  
OFF ON  
CAUTION:  
Label all wires prior  
Thermostat  
(Optional)  
(Millivolt)  
Remote  
Receiver  
(Optional)  
(Millivolt)  
to disconnection when servicing  
controls. Wiring errors can cause  
improper and dangerous operation.  
Remote Transmitter  
(Optional)  
WARNING:  
Electrical Grounding Instructions  
This appliance is equipped with a three pronged (grounding) plug for your protection  
against shock hazard and should be plugged directly into a properly grounded three-  
prong receptacle. Do not cut or remove the grounding prong from this plug.  
U32S-5 FPI Direct Vent Gas Insert  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
For PROPANE Units and Units Equipped with DC Spark Boxes*  
*For installation of the DC Spark Box refer to the LP Conversion instructions in this manual.  
16  
U32S-5 FPI Direct Vent Gas Insert  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
GLASS CRYSTAL OR OPTIONAL CERAMIC STONES  
INSTALLATION ON BURNER  
Spread the supplied Glass Crystals (or optional Ceramic  
Spa Stones) evenly over the burner. Ensure the crystals (or  
stones) do not overlap too much as this will effect the ame  
pattern.  
NOTE:Wheninstalling,useeitherthesuppliedGlassCrystalsor  
optional Ceramic Spa Stones - DO NOTcombine the two. Only  
the supplied approved Cobalt Blue Glass or optional 70 pieces  
of Ceramic Spa Stone are to be used with this replace. Use  
of any other type of glass crystals or stones can alter the unit's  
performance,anydamagecausedbytheuseofanyunapproved  
glass or stones will not be covered under warranty.  
Burner shown with Glass Crystals  
NOTE: When using Ceramic Stones, DO NOT cover burner  
ports that lead to pilot ame.  
Burner shown with optional Ceramic Stones  
Colbalt Glass Crystals/Ceramic Spa Stones Quantity  
Colbalt Crystals Ceramic Spa Stones  
P33S  
E33S  
U32S  
L676S  
1 bag  
1 bag  
1 bag  
1 bag  
70*  
70  
70  
70  
*Recommended to use only 50 of the 70 ceramic stones on the  
P33S burner.  
Minimum Air shutter Opening  
Glass Crystals  
Ceramic Stones  
Natural Gas  
Propane  
3/8"  
1/2"  
1/8"  
3/8"  
U32S-5 FPI Direct Vent Gas Insert  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
STANDARD  
To remove the ush door, reverse the above steps.  
FLUSH DOOR  
IMPORTANT NOTE: The chain must rest on TOP of the gas inlet  
pipe never under it.  
Thestandardushdoorcomeswithablackframe.Toinstalltheframe,  
simply hook the top door ange onto the top of the unit and swing the  
door towards the unit, diagram 1. Be careful that the glass gasket does  
not roll up; there must be a gap between the gasket and the door lip to  
ensure that the door sits securely on the unit. Diagram 2.  
Use the hook to pull the spring out until you can put the hook into the slot  
on the bottom door bracket. Repeat for 2nd spring. See diagram 3.  
Diagram 3  
Diagram 1a  
Diagram 1b  
Diagram 2  
18  
U32S-5 FPI Direct Vent Gas Insert  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
FACEPLATE AND DOOR FRAME INSTALLATION  
Kit# 425-914 Contents List:  
Note: Ensure that the flanges on the sides of the firebox are on the  
outside, when installing the faceplate (see below).  
1
1
1
2
2
4
1
1
Complete Faceplate with Switches  
Door Frame  
Bottom Louver  
Hinges  
Bottom Louver Brackets  
Pan Head Screws  
Wire Clip  
Faceplate  
Instruction Sheet  
Flange on firebox  
1) Bring the faceplate up in front of the unit and connect the red &  
black ON/OFF wires from the unit to the ON/OFF switch on the  
back of the left side of the faceplate.  
4) Fold down the 2 hinges on the bottom frame to a flat position.  
The bottom frame is installed with a friction fit - the opening in the  
corner of each hinge slides over the metal lip located on the floor of  
the unit.  
Note: Ensure the bottom frame is positioned properly before  
installing, by making sure there is equal spacing on either side.  
2) Connect the grey coated female ends of the black & red fan wires  
from the unit to the male ends of the fan rheostat on the left side of  
the faceplate as shown.  
Openings on hinge  
Metal Lip  
Fan Rheostat  
5) Push both bottom frame hinges down on the metal lip until  
they are fully seated.  
3) Position faceplate on unit lining up screw holes on faceplate with  
screw holes on unit - secure with 4 screws.  
6) Flip bottom louver up to close.  
U32S-5 FPI Direct Vent Gas Insert  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
7) Install the door frame by hooking the top flange over the top of the glass door.  
8) Lower the door frame gently into place.  
9) Run supplied 120V power cord along front face of masonry fireplace and plug into nearest receptacle.  
10) Slide unit into final position.  
Completed Faceplate & Door Frame Installation  
20  
U32S-5 FPI Direct Vent Gas Insert  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
OPTIONAL HEARTH TRIM INSTALLATION  
The Hearth Trim is an option that can be used to finish off the installation when the bottom of the fireplace is higher  
than the hearth or to raise the fireplace. The faceplate is assembled first and then the hearth trim is attached to the  
faceplate. There are 2 Hearth Trim options; a 2" and a 4".  
4" Hearth Trim Installation:  
2" Hearth Trim Installation:  
1) Secure the two 2" hearth trim pieces together as shown in  
1) Attach the Hearth Trim to the bottom of the faceplate side  
panels with the screws provided (3 per side) as shown in  
diagram 1. The holes in the Hearth Trim are oblong so the  
trim can be adjusted inwards or outwards as needed to suit  
finishing.  
diagram 2. Secure using the 2 screws provided.  
2) Attach the now 4" Hearth Trim to the bottom of the faceplate  
side panels with the screws provided (3 per side) as shown  
in diagram 1. The holes in the Hearth Trim are oblong so  
the trim can be adjusted inwards or outwards as needed to  
suit finishing.  
NOTE:Don'ttightenthescrewsdowncompletelyatthispoint,  
do a trial fit to the unit, make any necessary adjustments,  
when trim fits properly, tighten the screws.  
Diagram 2  
Diagram 1  
U32S-5 FPI Direct Vent Gas Insert  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATING INSTRUCTIONS  
1) Open the bottom louver assembly  
The glass panel may require cleaning  
after the unit has cooled down.  
DO NOT ATTEMPT TO CLEAN THE  
GLASS WHILE IT IS HOT.  
OPERATING  
INSTRUCTIONS  
2) If the control knob is in the "OFF" position  
proceed to Step 5.  
Beforeoperatingthisappliance,proceedthrough  
the following check list.  
3) Push in gas control knob slightly and turn  
clockwise to "OFF". Knob cannot be turned  
from"PILOT"to"OFF"unlessknobispushed  
in slightly. Do not force.  
Note: When the glass is cold and the  
appliance is lit, it may cause  
condensation and fog the glass.  
This condensation is normal and  
will disappear in a few minutes as  
the glass heats up.  
1) Read and understand these Instructions  
before operating this appliance.  
4) Wait ve minutes to allow gas, that may  
have accumulated in the main burner  
compartment, to escape. If you do smell  
gas, follow the instructions on the front of  
this manual. If you don't smell gas continue  
on to the next step.  
2) Check to see that all wiring is correct and  
enclosed to prevent possible shock.  
3) Check to ensure there are no gas leaks.  
DO NOT BURN THE APPLIANCE  
WITHOUT THE GLASS FRONT IN  
PLACE.  
During the rst few res, a white lm  
may develop on the glass front as part  
of the curing process. The glass should  
be cleaned or the lm will bake on and  
become very difcult to remove. Use a  
non-abrasive cleaner and NEVER clean  
the glass while it is hot.  
4) Make sure the glass door is in place. Never  
operate the appliance with the door glass  
removed.  
5) Turn the gas control counter clockwise to  
"PILOT".  
6) Push in control knob all the way and hold  
in. Continually push and release the black  
button on spark igniter until pilot lights.  
Continue to hold the control knob in for  
approximately one minute, then release  
the gas control knob. The pilot ame should  
continue to burn. If the pilot does not remain  
lit, repeatoperationallowingalongerperiod  
before releasing gas control knob.  
5) Verify that all venting and the cap is  
unobstructed.  
6) Verify log placement. If the pilot cannot be  
seen when lighting the unit - the logs or the  
embers have been incorrectly positioned.  
7) The unit should never be turned off and on  
again without a minimum of a 60 second  
wait.  
AUTOMATIC  
CONVECTION FAN  
OPERATION  
7) Turn gas control knob counter clockwise to  
"ON".  
8) When lighting the appliance, the inside of  
the glass may fog up. This will burn off after  
a few minutes of operation.  
8) Use the rocker switch to operate main  
burner.  
Thefanoperatesautomatically,turntheknobon  
the side of the faceplate to adjust to the desired  
speed. The fan will turn on as the insert comes  
up to operating temperature. After the unit has  
been turned off and the unit cooled to below a  
useful heat output range the fan will shut off  
automatically.  
9) Rotate the variable ame control to adjust  
DO NOT BURN THE APPLIANCE  
WITH THE GLASS ASSEMBLY  
REMOVED.  
the ame height higher or lower.  
10) Close the bottom louver assembly.  
SHUTDOWN  
PROCEDURE  
NORMAL OPERATING  
SOUNDS OF  
1) Use the rocker switch to turn off the main  
burner.  
GAS APPLIANCES  
2) Open the bottom louver assembly.  
It is possible that you will hear some sounds  
fromyourgasappliance.Thisisperfectlynormal  
due to the fact that there are various gauges  
and types of steel used within your appliance.  
Listedbelowaresomeexamples.Allarenormal  
operatingsoundsandshouldnotbeconsidered  
as defects in your appliance.  
LIGHTING  
PROCEDURE  
IMPORTANT  
To ignite or reignite the pilot, you must rst  
release the tension springs below the door.  
3) Push in the gas control knob slightly and  
turn clockwise to "OFF". Do not force.  
4) Disconnect all electric power and gas to the  
appliance if service is to be performed.  
FIRST FIRE  
Blower:  
Only when the pilot holds, without pressure  
being applied to the control knob, reapply the  
tension springs to the door. The unit must  
not be operated with the tension springs  
unattached.  
FPI gas appliances use high tech blowers to  
push heated air farther into the room. It is not  
unusual for the fan to make a "whirring" sound  
when ON. This sound will increase or decrease  
in volume depending on the speed setting of  
your fan speed control.  
The rst re in your insert is part of the paint  
curing process. To ensure that the paint is  
properly cured, it is recommended that you  
burn your replace for at least four (4) hours  
the rst time you use it with the fan on. When  
rst operated, the unit will release an odour  
caused by the curing of the paint, the burning  
off of any oils remaining from manufacturing.  
Smoke detectors in the house may go off at  
this time. Open a few windows to ventilate the  
room for a couple of hours.  
NOTE:Forallpropaneunitsandunitsequipped  
with electric spark boxes, see "Copy of Lighting  
Plate Instructions" section for more details.  
Burner Tray:  
The burner tray is positioned directly under  
the burner tube(s) and crystals and is made  
of a different gauge material from the rest of  
the rebox and body. Therefore, the varying  
thicknesses of steel will expand and contract at  
IMPORTANT: Gas on/off knob cannot be  
turned from "PILOT" to "OFF" unless it is  
partially depressed.  
22  
U32S-5 FPI Direct Vent Gas Insert  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATING INSTRUCTIONS  
slightly different rates which can cause "ticking"  
and"cracking"sounds.Youshouldalsobeaware  
that as there are temperature changes within  
the unit these sounds will likely re-occur.Again,  
this is normal for steel reboxes.  
COPY OF LIGHTING INSTRUCTION PLATE  
FOR YOUR SAFETY READ BEFORE LIGHTING  
1/  
NFPA 54, or Natural Gas and Propane Installation Codes, CSA B149.1. (Australia: A S5601-2004, New Zealand: NZS 5261)  
WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage,  
Blower Thermodisc:  
When this thermally activated switch turns ON  
it will create a small "clicking" sound. This is the  
switch contacts closing and is normal.  
or additional information consult a qualified installer, service agency or gas supplier.  
A) This appliance has a pilot which must be lighted by hand, following the instructions below exactly.  
B) BE FORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than  
air and will settle on the floor.  
WHAT TO DO IF YOU SMELL GAS  
Do not try to light any appliance  
Do not touch any electric switch, do not use any phone in your building  
Immediately call your gas supplier from a neighbors phone. Follow the gas supplier’s instructions.  
If you cannot reach your gas supplier, call the fire department.  
Pilot Flame:  
While the pilot ame is on it can make a very  
slight "whisper" sound.  
-
-
-
-
C) Us  
try to  
repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.  
Gas Control Valve:  
D) Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and  
to replace any part of the control system and any gas control which has been under water.  
As the gas control valve turns ON and OFF, a  
dullclickingsoundmaybeaudible,thisisnormal  
operation of a gas regulator or valve.  
E) Thisappliance needs fresh air for safe operation and must be installed so there are provisions adequate combustion + ventilation air.  
l
. Keep burner  
appliance.  
Unit Body/Firebox:  
LIGHTING INSTRUCTIONS  
STOP! Read the safety information above on this label.  
Different types and thicknesses of steel will  
expand and contract at different rates resulting  
in some "cracking" and "ticking" sounds will be  
heard throughout the cycling process.  
FOR UNITS NOT EQUIPPED WITH ELECTRIC SPARK:  
FORALL PROPANE UNITS AND  
UNITS EQUIPPED WITH ELECTRIC SPARK BOXES:  
1) Push in gas control knob slightly and turn clockwise  
to  
“OFF”. Knob cannot be turned from “PILOT” to “OFF” unless  
knob is pushed in slightly. Do not force.  
1) Push in gas control knob slightly and turn to “PILOT” position.  
OFF  
PILOT BURNER  
VEILLEUSE  
2) Push in control knob all the way and hold in untilthe pilot lights  
up. Continue to hold the control knob in for about 20 seconds  
after the pilot is lit. Release knob.  
THERMOPILE  
ELEMENT  
MAINTENANCE  
INSTRUCTIONS  
3) Push in gas control knob slightly and turn to "ON" position.  
THERMO-  
ELECTRIQUE  
4) Turn ON the flame switch.  
2) Wait five (5) minutes to clear out any gas. If you then smell gas  
STOP! follow “B” in the safety information above on this label. If  
you don’t smell gas, go to the next step.  
1) Always turn the gas valve to off before  
cleaning. For relighting, refer to lighting  
instructions. Keep the burner and control  
compartment clean by brushing and  
vacuuming at least once a year. When  
cleaning the logs, use a clean soft paint  
brush as the logs are fragile and easily  
damaged.  
3) Turn knob on gas control counterclockwise  
to “PILOT”.  
4) Push in control knob all the way and hold in. Immediately push  
black button on spark igniter until pilot lights. Continue to hold the  
control knob in for about 1/2 minute after the pilot is lit. Release  
knob and it will pop back up. Pilot should remain lit. If it goes out,  
repeat steps 3) and 4).  
If knob does not pop up when released, stop and immediately call  
your service technician or gas supplier.  
If the pilot will not stay lit after several tries, turn the gas control  
knob to “OFF” and call your service technician or gas supplier.  
5) Turn gas control knob counterclockwise  
6) Use rocker switch to operate main burner.  
to “ON”.  
2) Clean (never when unit is hot) appliance,  
doorandfaceplatewithadampcloth. Never  
useanabrasivecleaner.Thenishesonthe  
door frame and faceplate may be scratched  
if abrasives are used to clean them.  
TO TURN OFF GAS APPLIANCE  
1) Turn off the flame switch.  
nd turn clockwise  
to “OFF”. Do not force.  
med.  
2) Push in the gas control knob slightly a  
3) Turn off all electric power to the appliance if service is to be perfor  
You may shut off the pilot during prolonged non use periods to conserve fuel.  
The heater is nished in a heat resistant  
paintandshouldonlyberenishedwithheat  
resistantpaint(notwithwallpaint). FPIuses  
StoveBrite Paint - Metallic Black #6309.  
DO NOT REMOVE THIS INSTRUCTION PLATE  
918-474b  
6) Each time the appliance is lit, it may cause  
condensation and fog the glass. This  
condensation and fog is normal and will  
disappear in a few minutes as the glass  
heats up.  
WARNING: CHILDREN AND ADULTS  
SHOULD BE ALERTED TO THE  
HAZARDS OF HIGH SURFACE  
TEMPERATURE AND SHOULD STAY  
AWAYTOAVOIDBURNSORCLOTHING  
IGNITION.YOUNGCHILDRENSHOULD  
BE CAREFULLY SUPERVISED WHEN  
THEY ARE IN THE SAME ROOM AS  
THE APPLIANCE.  
3) Make a periodic check of burner for proper  
position and condition. Visually check the  
ameoftheburnerperiodically,makingsure  
the ames are steady; not lifting or oating.  
If there is a problem, call a qualied service  
person.  
Never operate the appliance without the  
glass properly secured in place or with  
the door open.  
4) The appliance and venting system must be  
inspected before use, and at least annually,  
byaqualiedeldserviceperson, toensure  
that the ow of combustion and ventilation  
air is not obstructed.  
7) Donotusethisapplianceifanyparthasbeen  
under water. Immediately call a qualied  
service technician to inspect the appliance  
andtoreplacenaypartofthecontrolsystem  
and any gas control which has been under  
water.  
CAUTION: ANY SAFETY SCREEN OR  
GUARDREMOVEDFORSERVICINGAN  
APPLIANCEMUSTBEREPLACEDPRIOR  
TO OPERATING THE APPLIANCE.  
During the annual service call, the burners  
should be removed from the burner tray  
and cleaned. Replace the embers but do  
not block the pilot.  
8) Periodically check the pilot ames. Correct  
amepatternhasthreestrongblueames:1  
owing around the thermopile and 1 around  
the thermocouple, and 1 owing across the  
rear of the burner (it does not have to be  
touching the burner).  
5) Keep the area near the appliance clear and  
free from combustible materials, gasoline  
and other ammable vapours and liquids.  
CLOTHING OR OTHER FLAMMABLE  
MATERIAL SHOULD NOT BE PLACED  
ON OR NEAR THE APPLIANCE.  
U32S-5 FPI Direct Vent Gas Insert  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MAINTENANCE  
GENERAL VENT  
MAINTENANCE  
DOOR GLASS  
Conduct an inspection of the venting system  
semi-annually. Recommended areas to inspect  
as follows:  
YourFPI insertissuppliedwithhightemperature,  
5mmNeoceramceramicglassthatwillwithstand  
the highest heat that your unit will produce. If  
your glass requires cleaning, we recommend  
using an approved glass cleaner available at  
all authorized dealers. Do not use abrasive  
materials. Do not clean the glass when hot.  
1) Check the Venting System for corrosion in  
areas that are exposed to the elements.  
These will appear as rust spots or  
streaks, and in extreme cases, holes.  
These components should be replaced  
immediately.  
Top View of pilot ame  
Intheeventthatyoubreakyourglassbyimpact,  
purchase your replacement from an authorized  
FPI dealer only, and follow our step-by-step  
instructions for replacement.  
Incorrectamepatternwillhavesmall, probably  
yellow ames, not coming into proper contact  
with the rear of the burner or thermopile.  
2) Remove the Termination Cap, and shine a  
ashlight down the Vent. Remove any bird  
nests, or other foreign material.  
Warning: Do not operate appliance  
withglasspanelsremoved,cracked  
orbroken.Replacementoftheglass  
should be done by a licensed or  
qualied service person.  
3) Check for evidences of excessive  
condensation,suchaswaterdropletsforming  
in the inner liner, and subsequently dripping  
outthejoints,Continuouscondensationcan  
cause corrosion of caps, pipe, and ttings.  
It may be caused by having excessive  
lateral runs, too many elbows, and exterior  
portions of the system being exposed to  
cold weather.  
Caution: Wear gloves when removing  
damaged or broken glass.  
Flush Glass Replacement  
4) Inspect joints, to verify that no pipe  
sections or ttings have been disturbed,  
and consequently loosened. Also check  
mechanical supports such as Wall Straps,  
or plumbers' tape for rigidity.  
Remove the ush door front (as per instructions  
in section "Standard Flush Door"). Remove the  
4 glass clips from each corner. Slide in the new  
replacement glass. Push the 4 glass clips back  
onto the frame.  
Top View of pilot ame  
If you have an incorrect ame pattern, contact  
your FPI dealer for further instructions.  
GLASS GASKET  
If the glass gasket requires replacement use  
glass gasket (Part # 936-155).  
24  
U32S-5 FPI Direct Vent Gas Insert  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MAINTENANCE  
5) Remove the glass door.  
FAN MAINTENANCE  
a) Removethe2hooksshownbelowatthebottomoftheglass  
If your fan requires maintenance or replacement, access to the fan is  
through the plate on the rear wall of the rebox. NOTE: the unit MUST  
NOT be operated without the fan access panel securely in place.  
door.  
b) Swingthedoorout45o fromthebottomandliftupand  
out.  
Caution:Labelallwirespriortodisconnectingwhenservicing  
controls. Wiring errors can cause improper and dangerous  
operation. Verify proper operation after servicing.  
7) Remove the burner by undoing the 2 screws shown.  
a) Carefully slide the burner to the left.  
b) Then lift the burner up and out carefully, ensuring not to spill  
the glass crystals.  
FAN REMOVAL  
1) Turn the unit off and allow it to cool down to room temperature.  
2) Disconnect the power source and turn off the gas supply to the  
insert.  
3) Open the bottom louver.  
4) Remove the door frame by lifting out from the bottom and lift up off  
the glass door.  
Burner  
Glass Door  
Door Frame  
U32S-5 FPI Direct Vent Gas Insert  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MAINTENANCE  
14) Remove the fan access plate by undoing the 10 screws shown.  
9) Remove the base cover by lifting up from the back and maneover  
out.  
Base Cover  
10) Remove the back panel by manoeuvring it up and out of the rebbox.  
as shown below.  
Fan access plate  
15) Remove the 3 screws securing the burner bracket as shown  
below.  
11) Remove 1 screw holding the clip securing the right side panel  
12) Remove the side panel.  
16) Move the pilot assembly out of the way - be careful of the wires  
leading from the pilot assembly.  
Pilot assembly wires  
13) Repeat above 2 steps to remove the left side panel.  
26  
U32S-5 FPI Direct Vent Gas Insert  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MAINTENANCE  
20) Lift Fan Assembly off of the 2 pins, tip foreward and pull through  
17) Remove the burner bracket.  
rebox opening.  
21) Disconnect green ground wire from power cord.  
18) Remove the Fan Air Duct by removing the 2 screws, squeeze the  
sides together to remove.  
REPLACING THE FAN  
Scrape off the old gasket from the Fan Access Panel, replace and  
reverse above steps to replace fan  
19) Unplug the 2 wires from the fan motor from inside the stove  
(located on the left side of the motor).  
Hint: When pushing fan down onto pins - rub a dab of dishsoap on  
the grommet so it will slide more easily onto the pin.  
Check to make sure the fan is seated properly on the pins, this is  
very important - try to move the fan back and forth, there shouldn't  
be any noise, if there is noise, check to see if the grommets have  
come loose.  
U32S-5 FPI Direct Vent Gas Insert  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MAINTENANCE  
VALVE ASSEMBLY REPLACEMENT  
1) Turn the unit off and allow it to cool down to room temperature.  
2) Disconnect the power source and turn off the gas supply to the  
insert.  
3) Open the bottom louver.  
4) Remove the door frame by lifting out from the bottom and lift up off  
the glass door.  
Burner  
8) Remove the base cover by lifting up from the back and maneover  
out.  
Glass Door  
Door Frame  
5) Remove the glass door.  
a) Removethe2hooksshownbelowatthebottomoftheglass  
door.  
b) Swingthedoorout45o fromthebottomandliftupand  
out.  
Base Cover  
9) Disconnect the ON/OFF connector wires from the valve.  
NOTE: For LP units disconnect the DC Sparker ignitor wire from the  
valve.  
6) Remove the burner by undoing the 2 screws shown. Carefully slide  
the burner to the left. Then lift the burner up and out ensuring not to  
spill glass crystals.  
7) Carefully set aside the burner and glass crystals.  
ON/OFF Wires  
28  
U32S-5 FPI Direct Vent Gas Insert  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MAINTENANCE  
10) Remove the valve tray by undoing the 12 screws as shown below.  
11) Slightly lift out valve tray.  
12) Disconnect the inlet gas line.  
13) Replace valve assembly and gasket, then reverse steps to reinstall new valve assembly.  
U32S-5 FPI Direct Vent Gas Insert  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PARTS LIST  
MAIN ASSEMBLY  
Part #  
Description  
Part #  
Description  
1) 420-122  
2) 420-142  
422-518/P  
Fan Access Panel  
Gasket - Fan Access Panel  
Fan Assembly:  
3) 910-215/P  
5) 910-750  
910-752  
Fan Motor (120 V)  
Power Cord (120 V)  
Wire Harness (intermediate)  
Thermodisc-Fan Auto ON/OFF  
Fan Switch Cover  
Thermodisc Bracket  
Flue Restrictor  
Left/Right Panels  
Rear Panel  
Levelling Bolt 5/16 x 3" Hex Hd  
Jack Chain  
Spring Lever Handle  
Door Extension Spring  
Wire Holder Clip  
7) 910-142  
8)  
9)  
*
*
10) 420-140  
12) 425-017  
425-015  
13) *  
14) 948-045  
15) 948-247  
16) 948-025  
17) *  
28  
25  
27  
26  
25  
24  
18) *  
Strain Relief  
19) *  
Grommet for Power Cord  
Conversion Kit to Propane  
514-969  
20) 420-157  
21) 420-054  
22) *  
23) 420-048  
24) *  
Gasket - Transition Box Bottom  
Gasket - Transition Box Top  
Stove Top  
Thermal Insulation  
Adaptor Stop  
23  
21  
21  
25) *  
26) *  
27) 320-518  
28) *  
Adaptor Holding Brkt-Left  
Adaptor Holding Brkt-Right  
Flue Adaptor Assy  
29  
20  
Insulation Hold Down Brkt  
29) 420-170  
30) 420-171  
31) 420-172  
Top Fan Air Channel  
Upper Fan Air Channel  
Lower Fan Air Channel  
19  
18  
17  
10  
32)  
Complete Flush Door Assembly  
Flush Glass  
U Clip  
940-307/P  
904-691  
936-155  
Tadpole Glass Gasket  
7
8
918-788  
Manual  
*Not available as a replacement part.  
30  
31  
5
14  
13  
15  
3
2
12  
1
32  
30  
U32S-5 FPI Direct Vent Gas Insert  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PARTS LIST  
BURNER ASSEMBLY  
Part #  
Description  
9) 910-038  
910-039  
10) 910-341  
11) 910-336  
12) 910-030  
13) 425-525  
Pilot Assembly 3 Flame - NG  
Pilot Assembly 3 Flame - LP  
Thermopile  
Thermocouple  
Electrode (not shown)  
U32S Sunrise burner assembly  
1) 910-568  
2) 904-430  
904-163  
3) 425-010  
4) 434-031  
5) 425-007  
425-574/P  
Valve - SIT NG / LP  
Burner Orice Nat. Gas #42  
Burner Orice LP # 54  
Pilot Holder  
Pilot Shield Hood  
Valve Tray  
Valve Assembly NG  
Valve Assembly LP  
Sunrise burner bracket  
Right Valve Bracket  
Left Valve Bracket  
*Not available as a replacement part.  
425-576/P  
6) 425-008  
7) 420-201  
8) 420-202  
4
10  
11  
13  
9
3
6
8
2
5
1
U32S-5 FPI Direct Vent Gas Insert  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PARTS LIST  
FACEPLATE AND DOORFRAME  
1) 425-512 Door Bottom Assembly  
2) 425-513 Frame Inside  
3) 425-514 Faceplate Outside  
4) 425-942 Hearth Trim  
3
2
1
4
32  
U32S-5 FPI Direct Vent Gas Insert  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTES  
U32S-5 FPI Direct Vent Gas Insert  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTES  
34  
U32S-5 FPI Direct Vent Gas Insert  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARRANTY  
Regency® Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit  
thoroughly before it leaves our facility. FPI Fireplace Products International Ltd. is pleased to extend this limited lifetime warranty to the original purchaser of a  
Regency® Product. This warranty is not transferable.  
The Warranty: Limited Lifetime  
The combustion chamber, heat exchanger, burner tubes/pans, logs, glass crystals, ceramic spa stones, pebbles, brick panels and gold plating (against defective manufacture  
only) are covered under the Limited Lifetime Warranty for ve (5) years for parts and subsidized labour* and parts only thereafter.  
Glass is covered for lifetime against thermal breakage only, parts and subsidized labour* for ve (5) years and parts only thereafter from date of purchase.  
External casting, surrounds and grills are covered against cracks and warps resulting from manufacturer defects, parts and subsidized labour* for three (3) years from the date  
of purchase and parts only thereafter.  
Special Finishes - One year on stainless steel panels, nickel overlays,nickel faceplates, brushed nickel and antique copper full screens and doors. You can expect some changes  
in color as the product "ages" with constant heating and cooling. FPI warranties the product for any manufacturing defects on the original product. However, the manufacturers  
warranty does not cover changing colors and marks, ie. nger prints, etc applied after the purchase of the product. Damage from the use of abrasive cleaners is not covered  
by warranty.  
Electricalandmechanicalcomponentssuchasblowers,switches,wiring,thermodiscs,FPIremotecontrols,spillswitches,thermopiles,thermocouples,pilotassemblycomponents,  
and gas valves are covered for two years parts and one year subsidized labour* from the date of purchase. Blowers and valves replaced under warranty are considered repairs and  
continue as if new with appliance. ie. twelve (12) months from original purchase date of appliance with a minimum of three (3) months coverage from date of replacement.  
FPI venting components are covered parts and subsidized labour* for three (3) years from date of purchase.  
Simpson Dura-Vent venting components (Direct Vent units) are covered by Simpson Dura-Vent Inc. warranty.  
Repair/replacement parts purchased by the consumer from FPI after the original coverage has expired on the unit will carry a 90 day warranty, valid with a receipt only. Any  
item shown to be defective will be repaired or replaced at our discretion. No labor coverage is included with these parts.  
Conditions:  
Any part or parts of this unit which in our judgement show evidence of such defects will be repaired or replaced at FPI's option, through an accredited distributor or agent provided  
that the defective part be returned to the distributor or agent Transportation Prepaid, if requested.  
Porcelain/Enamel - Absolute perfection is either guaranteed nor commercially possible. Any chips must be reported and inspected by an authorized dealer within three days of  
installation. Reported damage after this time will be subject to rejection.  
It is the general practice of FPI to charge for larger, higher priced replacement parts and issue credit once the replaced component has been returned to FPI and evaluated  
for manufacturer defect.  
The authorized selling dealer is responsible for all in-eld service work carried out on your Regency® product. FPI will not be liable for results or costs of workmanship from  
unauthorized service persons or dealers.  
At all times FPI reserves the right to inspect product in the eld which is claimed to be defective.  
All claims must be submitted to FPI by authorized selling dealers. It is essential that all submitted claims provide all of the necessary information including customer name,  
purchase date, serial #, type of unit, problem, and part or parts requested, without this information the warranty will be invalid.  
Exclusions:  
This limited Lifetime Warranty does not extend to or include paint, door or glass gasketing or trim.  
At no time will FPI be liable for any consequential damages which exceed the purchase price of the unit. FPI has no obligation to enhance or modify any unit once manufactured.  
ie. as products evolve, eld modications or upgrades will not be performed.  
FPI will not be liable for travel costs for service work.  
Installation and environmental problems are not the responsibility of the manufacturer and therefore are not covered under the terms of this warranty policy.  
Embers, rockwool, gaskets, door handles and paint are not covered under the terms of this warranty policy.  
Any unit which shows signs of neglect or misuse is not covered under the terms of this warranty policy.  
The warranty will not extend to any part which has been tampered with or altered in any way, or in our judgment has been subject to misuse, improper installation, negligence  
or accident, spillage or downdrafts caused by environmental or geographical conditions, inadequate ventilation, excessive offsets, negative air pressure caused by mechanical  
systems such as furnaces, fans, clothes dryer, etc.  
Freight damage to stoves and replacement parts is not covered by warranty and is subject to a claim against the freight carrier by the dealer.  
FPI will not be liable for acts of God, or acts of terrorism, which cause malfunction of the appliance.  
Performance problems due to operator error will not be covered by this warranty policy.  
Products made or provided by other manufacturers and used in conjunction with the operation of this appliance without prior authorization from FPI, may nullify your warranty  
on this product.  
Any alteration to the unit which causes sooting or carboning that results in damage to the interior / exterior faceplate is not the responsibility of FPI.  
* Subsidy according to job scale as predetermined by FPI.  
U32S-5 FPI Direct Vent Gas Insert  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FPI replaces are designed with reliability and simplicity  
in mind. In addition, our internal Quality Assurance Team  
carefully inspects each unit thoroughly before it leaves  
our door.  
FPIFireplaceProductsInternationalLtd.ispleasedtoextend  
this Limited Lifetime Warranty to the original  
purchaser of a FPI Product.  
See the inside back cover for details.  
Register your Regency® online at  
Installer: Please complete the following information  
Dealer Name & Address:______________________________________________  
___________________________________________________________________  
Installer: ___________________________________________________________  
Phone #: ___________________________________________________________  
Date Installed: ______________________________________________________  
Serial No.:__________________________________________________________  
FPI, Regency® and Sunriseare trademarks of FPI Fireplace Products International Ltd.  
Printed in Canada  
© Copyright 2009, FPI Fireplace Products International Ltd. All rights reserved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Radio Shack Cordless Telephone Digital Answering System with Caller ID Deluxe and 24 GHz Digital Spread Spectrum Cordless Phone User Guide
RCA Flat Panel Television 24F671T User Guide
RCA Portable CD Player RCD175 User Guide
Rhino Mounts Lawn Mower TURBO 96 User Guide
Rockford Fosgate Car Stereo System B050 000 User Guide
Rolls Music Mixer MX41b User Guide
Samsung Printer 7300N User Guide
Sanus Systems Indoor Furnishings VMCT User Guide
SATO Printer D512 PCL User Guide
Sears Sewing Machine 38516631 User Guide