Raypak Water Heater Commercial Boilers And Water Heater User Guide

RAYTHERM  
COMMERCIAL BOILERS AND WATER HEATERS  
T H E F I R S T A N D S T I L L T H E B E S T  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FEATURES  
Rugged  
All-Bronze  
Headers  
Finned Copper  
Tube Heat  
Exchanger  
Combination  
Modulating  
Valves  
Corrosion  
Resistant Steel  
24-Volt Controls  
are totally enclosed for  
protection. Door is  
Floating Return  
Header  
fittings are brush-  
galvanized against  
rust. Heat shields are  
corrosion-resistant  
steel. Jacket has  
Polytuf powder coat  
finish.  
immunizes heat  
exchanger to thermal  
shock.  
resist corrosion, and  
are easily removed for  
inspection or service.  
Cast iron headers with  
porcelainized  
waterways are  
available.  
single bank, straight  
through design  
delivers lowest  
pressure drop. Integral  
fins have ten times the  
heat transfer surface  
of plain tubes.  
automatically size  
boiler to loads as low  
as 20% of full input  
for maximum fuel  
economy. Standard on  
Type NH boilers.  
Optional on Type H  
and WH.  
easily removed for  
inspection and service.  
Tube Sheet and  
“ O” Ring  
Construction  
Interlocking  
Refractory  
Panels  
Stainless Steel  
Burners  
Slide-out Burner  
Tray  
Spark-to-Pilot  
Ignition  
maintain precise  
combustion at all  
firing rates, burn  
quietly and won’t clog  
or corrode.  
allows easy inspection  
and service.  
the most dependable  
ignition method  
available.  
eliminates the repair  
and maintenance  
problems associated  
with rolling tubes  
directly into a casting.  
with sealed corners  
reduce radiation  
losses.  
Indoor/outdoor  
construction  
RaythermTM Atmospheric  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MODEL INFORMATION  
Models 514-824  
Models 133, 181-401  
Indoor model shown  
Outdoor model shown  
Indoor model shown  
MBTUH†  
Dimensions (in.)  
Overall Height  
Indoor Outdoor  
45 38-1/2 24-1/8 1-1/4  
Model  
No.  
MBTUH†  
Dimensions (in.)  
Water Flue  
Conn. Dia.  
Input Output Width  
Depth  
Model  
No.  
Overall Height  
Water Flue  
Conn. Dia.  
Input Output Width  
Depth  
133  
136  
112 14-1/4  
6
6
7
8
9
Indoor Outdoor  
514  
624  
724  
824  
512  
627  
726  
825  
419 32-3/4  
514 37-1/2  
595 41-5/8  
677 45-3/4  
57  
57  
57  
57  
44-1/8 29-1/2  
44-1/8 29-1/2  
44-1/8 29-1/2  
44-1/8 29-1/2  
2
2
2
2
10  
12  
12  
14  
181/182 181  
260/261 264  
330/331 334  
148 18-1/4 62-5/8  
216 22-3/8 62-7/8  
274 25-3/4 63-3/4  
40  
40  
40  
40  
26-1/2 1-1/2  
26-1/2 1-1/2  
26-1/2 1-1/2  
26-1/2 1-1/2  
400/401 39932729-1/4 65-3/8  
Natural gas and propane  
For natural gas units; For propane units, use .94 multiplier  
For 2-stage Model 401 (low NOx) units, derate 5%  
Models 926-1826  
Models 2100-4001  
Outdoor model shown  
MBTUH†  
Dimensions (in.)  
Model  
No.  
Overall  
Height  
Water Flue  
Conn.Dia.  
Input  
Output  
Width  
Depth  
Outdoor  
926  
926  
759  
888  
966  
1055  
1159  
1287  
1442  
52-3/8 46-3/4 32-1/2  
59-1/4 46-3/4 32-1/2  
63-5/8 46-3/4 32-1/2  
68-5/8 46-3/4 32-1/2  
74-7/8 46-3/4 32-1/2  
81-1/8 46-3/4 32-1/2  
89-3/8 46-3/4 32-1/2  
2-1/2  
2-1/2  
2-1/2  
2-1/2  
2-1/2  
2-1/2  
2-1/2  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
Indoor model only  
1083  
1178  
1287  
1414  
1571  
1758  
Indoor  
962  
1125  
1223  
1336  
1468  
1631  
1826  
1083  
1178  
1287  
1413  
1570  
1758  
MBTUH†  
Dimensions (in.)  
Model  
No.  
Overall  
Height  
Water Flue  
Conn.Dia.  
Input  
Output  
Width  
Depth  
962  
789  
922  
52-3/8 76-1/8 32-1/2  
59-1/4 78-1/8 32-1/2  
63-5/8 78-1/8 32-1/2  
68-5/8 80-1/8 32-1/2  
74-7/8 80-1/8 32-1/2  
81-1/8 80-1/8 32-1/2  
89-3/8 80-1/8 32-1/2  
2-1/2  
2-1/2  
2-1/2  
2-1/2  
2-1/2  
2-1/2  
2-1/2  
14  
16  
16  
18  
18  
18  
20  
2100  
2500  
3001  
3500  
4001  
2100  
2499  
3000  
3500  
4000  
1722  
2049  
2460  
2870  
3280  
61  
68-1/4 54-3/4  
68-1/4 54-3/4  
68-1/4 54-3/4  
68-1/4 54-3/4  
68-1/4 54-3/4  
3
3
3
3
3
24  
26  
28  
30  
32  
1125  
1226  
1337  
1467  
1630  
1826  
70  
1002  
1096  
1203  
1337  
1497  
81-1/8  
92-1/2  
103-3/4  
Natural gas and propane  
‡ 4” on single-pass boilers (Type H)  
For natural gas units; For propane units, use .92 multiplier for indoor, .955 multiplier for outdoor  
‡ 3NPT on single-pass boilers (Type H)  
Catalog No.: 1000.18A Effective: 05-01-06 Replaces: 01-01-06  
Raypak Inc., 2151 Eastman Ave., Oxnard, CA 93030  
(805) 278-5300 Fax (800) 872-9725  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Quantum Audio Network Card PX502 User Guide
Radio Shack Portable Radio FRS 105 User Guide
Radio Shack Telephone 43 3909 User Guide
Radio Shack Video Game Controller 26 447 User Guide
Rowenta Iron Werke User Guide
Royal Sovereign Laminator RSH 380 User Guide
Samsung Computer Drive HX MU025DC User Guide
Sanyo Digital Camera VCC 3944 User Guide
Schneider Electric Power Hammer Class 615 User Guide
Sega Video Games MAN S075 UK User Guide