Hi Delta® - Type H
Job:
Engineer:
Contractor:
Prepared By:
Model:
Hydronic Heating Boiler
Models 992BE-2342BE
Date:
87% Efficiency
MBTUH Input:
Indoor/Outdoor:
100% Factory Fire Tested
Efficiency: 87%
Maximum Outlet Temperature: 230°F
Minimum Non-Condensing Inlet Temperature: 120°F
Thermal Shock Proof Heat Exchanger
Limited Twenty-Year Thermal Shock Warranty
Limited Ten-Year Closed-System Heat Exchanger
Warranty
Diagnostic Center with Fault History
PolyTuf Powder Coated Cabinet
No Combustible Floor Shield Required
Fan-Assisted
Patented Burner Security Blanket
Heat Exchanger
Gas Train
Burner
H Stamp
Headers
Manual Gas Shut-Off Valve(s)
Ultra-Low NOx: Less than 30 PPM
Gas Pressure Regulator
Safety Shut-Off Valve
Firing Control Valve
Low Gas Pressure Switch, Manual
Firing Mode
Temperature Controls
Glass-Lined Cast Iron – Standard
B- TempTracker Digital Controller,
4-Stage
Y-241 Electronic Sequencer, 4-Stage
Y-281 Electronic Sequencer, 8-Stage
Bronze – Option A-1
ASME Inspected and Stamped
160 PSIG Working Pressure
National Board Approved
Fin Tubing
3-Stage (H8): Model 992BE
4-Stage (H9): Models 1262BE -
2342BE
Options
Copper – Standard
C-6 Ignition Module, Manual Reset
D-21 TruSeal® Direct Vent
F-10 Low Water Cut-Off, Remote
Probe
Cupro Nickel – Option A-3
ASME Steel Tube Sheet
Silicone High Temp. O-Rings
ASME Pressure Relief Valve
60 PSIG – Standard
Fuel
Natural Gas
Propane Gas
4” WC Gas Supply Pressure
G-20
I-1
High Limit Control, Auto Reset
P-
Pump:
60Hz
HP, 120V, 1∅,
PSIG – Optional
Design Certified ANSI Z21.13/
CSA 4.9
Temperature and Pressure Gauge
Water Connections
Water Hardness:
Cast Iron
Mounted
GPG
Bronze
Loose
Rear
Construction
Left – Standard
Right – Option A-6
Indoor/Outdoor Construction
Enclosed Front Controls
Front
P-26 Cold Water Start (See 2000.49)
S-2 High Gas Pressure Switch,
Manual
X-1 SureRack™ Kit
X-2 SureRack Add-on
Controls
Venting
120V, 60Hz, 1∅ Power Supply
Vent Location
120/24V 60Hz Transformer
100% Shut-Off/Lockout
Hot Surface Ignition
Top – Standard
Rear – Option D-14
Vent Termination Cap
Outdoor D-11
Indoor, Horizontal D-15
Indoor, Vertical (by others)
Combustion Air
In-Line Filter Kit (TruSeal only)
D-17
Air Intake Elbow D-16
Extractor – Optional
By others
Remote Flame Sensor
High Limit Control, Manual Reset
On/Off Power Switch
Manual Shut-Off, Front-Mounted
Flow Switch
Blocked Vent Pressure Switch
Combustion Air Proving Switches
Economaster Pump Time Delay
Enable/Disable
Regulatory Agency Requirements
Not required
Catalog No.: 2000.451E
Effective: 11-15-07
Replaces: 1-1-07