Raypak Water Heater 992BD 2342BD User Guide

Hi Delta® FlexGas® - Type H  
Job:  
Engineer:  
Contractor:  
Prepared By:  
Model:  
Dual-Fuel Hot Water Boilers  
Models 992BD-2342BD  
Date:  
Indoor/Outdoor:  
MBTUH Input:  
Fast, Economical Natural-to-Propane Gas Switchover  
100% Factory Fire Tested  
84% Efficiency  
Maximum Outlet Temperature: 230°F  
Minimum Non-Condensing Inlet Temperature: 105°F  
Thermal Shock Proof Heat Exchanger  
Limited Twenty-Year Thermal Shock Warranty  
Diagnostic Center with Fault History  
PolyTuf Powder Coated Cabinet  
No Combustible Floor Shield Required  
Fan-Assisted Low NOx Burners  
Patented Burner Security Blanket  
Patent Nos. 6,904,873 & 7,044,124;  
other patents pending  
Heat Exchanger  
Gas Train  
Burner  
ƒ
ƒ
H Stamp  
Headers  
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
Manual Gas Shut-Off Valve(s)  
ƒ
Ultra-Low NOx: Less than 30 PPM  
Gas Pressure Regulator  
Safety Shut-Off Valve  
Firing Control Valve  
Low Gas Pressure Switch, Manual  
Firing Mode  
Temperature Controls  
Glass-Lined Cast Iron – Standard  
B- TempTracker Digital Controller,  
4-Stage  
Y-241 Electronic Sequencer, 4-Stage  
Y-281 Electronic Sequencer, 8-Stage  
Bronze – Option A-1  
ASME Inspected and Stamped  
160 PSIG Working Pressure  
National Board Approved  
Fin Tubing  
ƒ
ƒ
ƒ
3-Stage (H8): Model 992BD  
4-Stage (H9): Models 1262BD -  
2342BD  
Options  
Copper – Standard  
C-6 Ignition Module, Manual Reset  
D-21 TruSeal® Direct Vent  
F-10 Low Water Cut-Off, Remote  
Probe  
Cupro Nickel – Option A-3  
ASME Steel Tube Sheet  
Silicone High Temp. O-Rings  
ASME Pressure Relief Valve  
60 PSIG – Standard  
ƒ
ƒ
Natural/Propane Gas  
Gas Connection  
Left – Standard  
Right – Option Z-1  
Design Certified ANSI Z21.13/  
CSA 4.9  
ƒ
ƒ
ƒ
I-1  
High Limit Control, Auto Reset  
ƒ
P-  
Pump:  
60Hz  
HP, 120V, 1,  
PSIG – Optional  
ƒ
ƒ
Temperature and Pressure Gauge  
Water Connections  
Water Hardness:  
Cast Iron  
Mounted  
GPG  
Bronze  
Loose  
Rear  
Venting  
ƒ
Vent Location  
Left – Standard  
Right – Option A-6  
Top – Standard  
Rear – Option D-14  
Vent Termination Cap  
Outdoor D-11  
Indoor, Horizontal D-15  
Indoor, Vertical (by others)  
Combustion Air  
In-Line Filter Kit (TruSeal only)  
D-17  
Air Intake Elbow D-16  
Extractor – Optional  
By others  
Front  
P-26 Cold Water Start (See 2000.49)  
S-2 High Gas Pressure Switch,  
Manual  
X-1 SureRack™ Kit  
X-2 SureRack Add-on  
Controls  
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
120V, 60Hz, 1Power Supply  
120/24V 60Hz Transformer  
100% Shut-Off/Lockout  
Hot Surface Ignition  
ƒ
ƒ
Remote Flame Sensor  
High Limit Control, Manual Reset  
On/Off Power Switch  
Manual Shut-Off, Front-Mounted  
Flow Switch  
Blocked Vent Pressure Switch  
Combustion Air Proving Switches  
Economaster Pump Time Delay  
Enable/Disable  
Regulatory Agency Requirements  
Not required  
Construction  
ƒ
ƒ
Indoor/Outdoor Construction  
Enclosed Front Controls  
Catalog No.: 2000.313A  
Effective: 11-15-07  
Replaces: 8-15-07  
Download from Www.Somanuals.com. All Manuals Search And Download.  

PYLE Audio TV DVD Combo PLDVD10M User Guide
Rotel Stereo Amplifier RB 991 User Guide
Rotel Stereo Amplifier RC 1082 User Guide
Ryobi Laminate Trimmer TR45 User Guide
Samsung Car Video System HD948 XSS User Guide
Samsung Flat Panel Television LA32A650A1R User Guide
Sanyo Car Stereo System CH3672R User Guide
Sanyo CRT Television CE28WN3 B User Guide
Scag Power Equipment Lawn Mower SFW36 16BV User Guide
Sears Cooktop 32025 User Guide