CATALOG NO: 2100.51-J
Effective: 06-15-00
Replaces: 11-01-99
USER'SINFORMATIONMANUAL
GAS FIRED RESIDENTIAL
HEATINGBOILERS
MODELS H- 0030B, 0042B, 0066B, 0090B, 0135B, 0180B
WARNING: If the information in this manual is not followed exactly, a fire or explosion
may result causing property damage, personal injury or loss of life.
- Do not store or use gasoline or other flammable vapors and liquids or other
combustible materials in the vicinity of this or any other appliance. To do so may
result in an explosion or fire.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do notuse any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas
supplier'sinstructions.
• If you cannot reach your gas supplier, call the fire department.
- Installation and service must be performed by a qualified installer, service agency
or the gas supplier.
This User's Information Manual is provided with the
necessary information for the proper operation and main-
tenance of these Raypak boilers. Please review and follow
these procedures carefully. Keep this manual in a safe
and accessible place for easy reference in the future.
stand before operating the boiler.
WARNING: If you do not follow these instructions
exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
BLOCKED VENT SHUT-OFF SYSTEM
A. This boiler has a pilot which must be lighted by
hand. When lighting the pilot, follow these instruc-
tions exactly.
This boiler is equipped with a blocked vent shut-off
system designed to shut off main burner gas in the event
the venting system is totally blocked.
B. BEFORE LIGHTING Smell all around the boiler
area for gas. Be sure to smell next to the floor
because some gas is heavier than air and will settle
on the floor.
In the event the blocked vent shut-off system is actu-
ated, do not attempt to place the boiler in operation, but
contact a qualified service agency.
FLAME ROLL-OUT SAFETY SHUT-OFF SYSTEM
This boiler is equipped with a flame roll-out safety shut-
off system designed to shut-off the main burner gas in the
event of sustained flame roll-out.
In the event the flame roll-out safety system is actu-
ated, do not attempt to place the boiler in operation, but
contact a qualified service agency.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch;
• Do not use any phone in your building.
• Immediately call your gas supplier from a
neigh-
bor's phone. Follow the gas supplier's instruc-
tions
CAUTION: Improper care and maintenance of flue and
venting system can cause a hazardous condition which
may result in injury or property damage.
• If you cannot reach you gas supplier, call the
fire department.
C. Use only your hand to push in move or turn the
gas control knob or lever. Never use tools. If the
knob or lever will not push in move or turn by hand,
LIGHTING INSTRUCTIONS FOR
STANDING PILOT MODELS.
Some safety information you need to read and under-
P/N 240490
Download from Www.Somanuals.com. All Manuals Search And Download.
FOR INTERMITTENT IGNITION (IID) WITH
HONEYWELL OR ROBERTSHAW GAS VALVE
(For All Models)
is to be performed.
3. For Honeywell Valve:
Turn gas control knob clockwise
Make sure knob rest against stop.
For Robertshaw Valve:
to "Off".
1. STOP! Read the safety information above.
2. Set the thermostat to the lowest setting.
3. Turn off all electric power to the appliance.
4. This boiler is equipped with an ignition device
which automatically lights the pilot. Do not try to light
the pilot by hand.
Push in and move gas control lever to "Off"
position.
GAS CONTROL
KNOB SHOWN
IN "ON" POSITION
GAS INLET
Fig.#8087.0
HONEYWELL
(Models 30 - 90)
HONEYWELL PILOT
5. For Honeywell Valve: Turn gas control knob
clockwise
to "Off".
CAUTION: Should overheating occur or the gas sup-
ply fails to shut off, DO NOT turn off or disconnect the
electrical supply to the pump. Instead, shut off the gas
supply at a location external to the appliance. Failure
to observe this precaution may aggravate the over-
heated condition resulting in possible damage to the
boiler and injury to the user.
For Robertshaw Valve: Push in and move gas
control lever to "Off" position.
6. Wait 5 minutes to clear out any gas. Then smell for
gas, including near the floor. If you smell gas,
STOP! Follow "B" in the safety information above
on this label. If you don't smell gas, go to the next
step.
7. For Honeywell Valve: Turn gas control counter-
INSPECTION AND MAINTENANCE
PROCEDURES
clockwise
to "On".
For Robertshaw Valve: Move gas control lever to
It is a good practice to make a periodic inspection
of the boiler. It is recommended that the home owner
or user check's the boiler after the first and third month
of operation, and then on an annual basis, or more
often if desired. It is also recommended to have a
qualified service agency check the boiler before each
heating season, or at anytime there may be an indica-
tion of a problem.
"On" position.
GAS CONTROL
KNOB SHOWN
IN "OFF"
POSITION
DANGER: Keep boiler area clear and free from
combustibles and flammable materials. Do not o b -
struct the flow of combustion and ventilating air into
the boiler enclosure. Failure to observe these safety
precautions can cause fire, explosion, or asphyxia-
tion.
GAS INLET
Fig. #8934.0
ROBERTSHAW
(All Models)
8. Turn on all electric power to the boiler.
9. Set thermostat to desired setting.
10. If the boiler will not operate, follow the instruction
"To Turn Off Gas To Boiler" and call your service
technician or gas supplier.
BLUE FLAME
TO TURN OFF GAS TO BOILER
1. Set the thermostat at the lowest setting.
2. Turn off all the electric power to the boiler if service
Fig.#9295
3
Download from Www.Somanuals.com. All Manuals Search And Download.
1. Burner Inspection.
3. Circulator (Water Pump) Inspection.
Clean the main burners and air louvers of dust, lint
The circulator is permanently lubricated and thus,
and debris. With burner in operation, make a visual will not require any lubrication. Inspect for evidence of
check of the burner flame and the pilot flame (when water leakage. This should be corrected to prevent any
equipped). Yellow flames indicate some restriction of possible damage to electrical components of the boiler.
combustion air openings. A bright orange, luminous
flame is not normal and can cause sooting under CAUTION: In case of a prolonged power failure during
prolonged operation. Should this condition be ob- freezing weather conditions, boiler and piping system
served, contact immediately a qualified service agency must be drained completely to avoid possible damage
to correct the problem.
to the heating system.
2. Venting System Inspection.
To prevent the potential freezing damage to the
heating system, it is recommended that the following
system shut down procedure be performed.
Visually inspect the venting system. Make sure the
vent connections are secure and have not become
disengaged. Look for any indication of corrosion, or
carbon (soot) streaks which could cause leakage of
products of combustion into the living space. Inspect
the vent terminal outside the building. Make sure it is
not damaged to cause blockage or restriction of the flue
gas. Observe for any indication of soot. The presence
of soot accumulation in the vent terminal would indicate
an abnormal operating condition. This should be
investigated and corrected by a qualified service
agency.
SYSTEM SHUT DOWN PROCEDURE
1. Set the room thermostat to "OFF" or the lowest
setting.
2. Turn off all electric switches to the boiler.
3. Turn off all gas valves supplying gas to the boiler.
Refer to operating instruction label on the boiler.
4. Shut off the water supply to the boiler piping system
loop.
5. Open drain valve on the boiler to remove water
from the boiler and the piping circuits.
SOOT
NOTE: It may be necessary to open the purge valves
and/or manual air vents to facilitate complete drainage
of water from the heating system.
4. Service Assistance.
If service is required on the boiler, contact your
local service agency or Raypak, Inc. can refer you to the
proper qualified service agency. It is important and very
often will save time if you state the model number, serial
number and type of gas used. This information will be
found on the nameplate of the boiler.
CORROSION
DISENGAGED
Fig.#8204.0
Raypak, Inc., 31111 Agoura Road, Westlake Village, CA 91361-4699 (818) 889-1500 FAX (818) 889-4522
4
Download from Www.Somanuals.com. All Manuals Search And Download.
|