Raypak Boiler 182 400 User Guide

Raytherm® - Type H  
Job:  
Engineer:  
Contractor:  
Prepared By:  
Model:  
Hydronic Heating Boilers  
Models 182-400 - Indoor  
Date:  
Indoor  
EFFICIENT  
82% efficiency – highest of any atmospheric boiler  
available today  
THERMAL SHOCK PROOF  
Twenty-year warranty against thermal shock damage  
up to 150°F differential  
Maximum operating temperature: 230°F  
LIGHTWEIGHT  
A floor load of 70 lbs./sq. ft. or less  
HIGH RECOVERY  
Cuts fuel costs substantially because the standby and  
radiation losses normal to other boilers and  
tank-type water heaters are eliminated  
LOW WATER OPERATING TEMPERATURE  
Operates with water temperature as low as  
105°F without condensing  
Heat Exchanger  
Gas Control Train  
Temperature Controls  
ƒ
ASME Inspected and Stamped  
160 PSIG  
National Board Approved  
Headers  
Cast Iron Glass-lined – Standard  
Bronze – Option A-1  
Finned Tubing  
ƒ
ƒ
ƒ
ƒ
ƒ
Manual Main Gas Shut-off Cock  
Note: H1 and H5 do not require a  
controller  
Main Gas Pressure Regulator  
Redundant Safety Shut-off Valve  
Control Valve  
ƒ
ƒ
B-6 Two-stage – 100-200ºF  
Y-241 Electronic Sequencer,  
1-4 Stages  
Y-281 Electronic Sequencer,  
1-8 Stages  
Firing Mode  
On/Off (H4)  
ƒ
Two-stage Firing (H3)  
Mechanical Modulation,  
110-170°F (H5)  
Mechanical Modulation,  
150-210°F (H1)  
Copper – Standard  
Cupro Nickel – Option A-3  
ASME Steel Tube Sheet  
Silicone O-Rings  
ASME Pressure Relief Valve  
45 PSIG – Standard  
PSIG ASME – Optional  
Temperature and Pressure Gauge,  
Shipped Loose  
Additional Safety Controls  
ƒ
ƒ
ƒ
F-10 Low Water Cut-off Probe  
I-1  
High Limit Control, Auto  
Reset, 240°F  
ƒ
ƒ
Fuel  
Natural Gas  
Propane Gas  
Design Certified ANSI Z21.13  
S-1 Low Gas Pressure Switch,  
Manual  
S-2 High Gas Pressure Switch,  
Manual  
ƒ
ƒ
Construction  
Water Connections  
ƒ
ƒ
ƒ
ƒ
Front Controls  
Left Hand – Standard  
Right Hand – Option A-6  
Flow Configuration – Two-pass  
Pump – Optional  
Stainless Steel Burners  
Polytuf Powder Coat Finish  
Vent Selection  
Draft Diverter – Option D-10  
Power Vent, Loose – Option D-2  
Base (Optional)  
ƒ
ƒ
Regulatory Agency Requirements  
Mounted, 1/8 HP, 120 Volt, 1, 60 Hz  
Controls  
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
120V, 60Hz, 1 Ph Power Supply  
120/24V Transformer  
100% Pilot Shut-off/Lockout  
Electronic, Intermittent Ignition (IID) Pilot  
High Limit Control, Manual Reset  
On/Off Switch  
Combustible Floor Shield –  
Option J-1  
Flow Switch  
Economaster II Pump Time Delay  
Catalog No.: 2000.205D  
Effective: 1-1-08  
Replaces: 4-1-05  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Raritan Computer Calculator PMG 0I v203 E User Guide
RCA MP3 Player M4202 User Guide
Riccar Vacuum Cleaner GEM R User Guide
Roland Music Pedal VG 99 User Guide
Roland Switch MSQ 100 User Guide
Ryobi Blower RESV1300 User Guide
Samsung DVR SRN 472S 1TB User Guide
Samsung Laptop NP270E5EK01JM User Guide
Samsung Printer ML 1710 User Guide
Samsung Security Camera SCC C4253P User Guide