Raypak Automobile 504 2004 User Guide

Job:  
MVB® - Type P  
Pool Heaters  
Models 504-2004  
Engineer:  
Contractor:  
Prepared By:  
Model:  
Date:  
Indoor/Outdoor:  
85% Thermal Efficiency  
100% Factory Fire Tested  
Pump included  
standard  
Minimum Acceptable Inlet Water Temperature: 105°F  
Full Safety Diagnostics with History  
Footprint: Less Than 5-1/2 ft2  
Limited Twenty-Year Thermal Shock Warranty  
Limited Five-Year Heat Exchanger Warranty  
On/Off Firing  
Soft-Start Modulating Controller with LCD Display  
Status Display Lights  
Heat Exchanger  
Bronze Headers  
Control (cont.)  
Temperature Controllers  
B-26 TempTracker Digital Controller,  
Up to 2 Heaters  
On/Off Digital Poolstat, 106°F Max  
Water Temperature Sensors (3) with  
Immersion Well  
ASME HLW Stamped  
160 PSIG Working Pressure  
National Board Approved  
Cupro Nickel Fin Tubing  
ASME Powder-Coated Tube Sheet  
Silicone High Temp O-Rings  
ASME Pressure Relief Valve,  
125 PSIG  
Temperature and Pressure Gauge,  
Shipped Loose  
Stainless Steel Evaporator Plate  
Bronze Pump (See table on pg. 2)  
Drain Valves (2)  
B-21 TempTracker Digital Controller,  
Up to 4 Heaters  
Y-241 Electronic Sequencer,  
Up to 4 Heaters  
Y-281 Electronic Sequencer,  
Up to 8 Heaters  
Burner  
Ultra-Low NOx: Less than 20 PPM  
Gas Train  
Fuel  
Natural Gas  
Propane  
Zero Governor Regulator  
Dual-Seat Combination Valve  
On/Off Firing with Soft-Start  
Options  
F-10 Low Water Cut-Off, Remote  
Probe  
P-  
P-  
S-1  
Cold Water Run  
H-style Bypass, Non-Ferrous  
Low Gas Pressure Switch,  
Manual Reset  
Construction  
Air Vent  
Indoor/Outdoor Construction  
Enclosed Front Controls  
PolyTuf Powder Coat Finish  
Rear Connections (Water, Electrical,  
Gas, Vent, Combustion Air)  
Design Certification  
Control  
S-2  
High Gas Pressure Switch,  
Manual Reset  
120V, 60Hz, 1Ø, Power Supply  
120/24V 60Hz Transformer  
Ignition Module  
Regulatory Agency Requirements  
3-Try – Standard  
Single-Try – Option C-6  
Hot Surface Ignition (HSI)  
Remote Flame Sensor  
High Limit, Auto Reset, Adj., 140°F  
High Limit, Manual Reset, Fixed  
Models 504-1504: 175°F  
Models 2004: 200ºF  
On/Off Power Switch  
Flow Switch, Mtd  
Blocked Vent Pressure Switch  
Combustion Air Proving Switch  
Pump Switch  
Models 504-1504: ANSI Z21.56/  
CSA 4.7  
Model 2004: ANSI Z21.10.3/CSA 4.3  
Venting  
Vent Termination Cap  
Outdoor – Option D-11  
Indoor, Horizontal – Option D-15  
Indoor, Vertical (by others)  
Combustion Air  
In-Line Filter Kit – Option D-17  
Air Intake Elbow – Option D-16  
Extractor – Optional  
By others  
L
W
Pump Time Delay  
Diagnostics Panel  
Not required  
Catalog No.: 6000.29B  
Effective: 7-15-08  
Replaces: 1-1-08  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Quantum Computer Drive DLT S4 User Guide
Radio Shack Universal Remote Kameleon 4 in One User Guide
RCA Camcorder CC6394 User Guide
RCA Radio RP5640 User Guide
Remington Power Tools Chainsaw 107624 02 User Guide
Sampo DVR DR S0426 User Guide
Samsung Headphones GH68 15048A User Guide
Sangean Electronics Weather Radio RCR 7WF User Guide
Sanyo Flat Panel Television DP50740 User Guide
Sanyo Vacuum Cleaner SC A114 User Guide