Raritan Engineering Marine Sanitation System PST02 User Guide |
®
PURASAN
(Models PST*02 and PST*03 [*specify 12,24,32] Manufactured after September, 2004)
OPERATION, MAINTENANCE AND INSTALLATION INSTRUCTIONS
THE FOLLOWING ARE CAUTIONARY STATEMENTS THAT MUST BE READ AND
FOLLOWED DURING BOTH INSTALLATION AND OPERATION
WARNING: Raritan Engineering Company, Inc. recommends that a qualified person or electrician install this product.
Equipment damage, injury to personnel or death could result from improper installation. Raritan Engineering
Company, Inc. accepts no responsibility or liability for damage to equipment, or injury or death to personnel
that may result from improper installation or operation of this product.
WARNING: HAZARD OF SHOCK AND FIRE
Always use recommended fuse or circuit breaker and wire size.
WARNING: HAZARD OF FLOODING - When leaving the boat unattended always be sure seacocks are closed. Any
installation made below waterline should have double hose clamps securing lines. The halogen disinfectant is
corrosive to aluminum, copper and steel. The plumbing system must not include any aluminum, copper
or steel fittings, piping or holding tanks.
IMPORTANT SAFETY INSTRUCTIONS FOR HANDLING PURASAN® TABLETS AND SOLUTION
WARNING: HAZARD OF DANGEROUS CHEMICAL REACTION
1. Use ONLY Purasan Tablets.
2. DO NOT add any other chemicals or cleaning products to the toilet or the treatment system. Raritan C.P. - Cleans
Potties and R.C. Raritan Concentrate are the only factory-recognized cleaning product that may be used in the
toilet.
WARNING: HAZARD OF SEVERE INJURY
1. DO NOT allow tablets to come in contact with skin, eyes or clothing. If contact occurs, immediately wash
affected area with fresh water. Remove and wash any affected clothing.
2. Use a well ventilated area when handling Purasan Tablets. DO NOT breathe dust from tablets - severe damage to
mucous membrane of the respiratory passages could occur.
3. Do not ingest.
4. Follow all cautions and warnings associated with handling of tablets.
5. When reloading the Tablet Dispenser, ventilate area well and wear chemical resistant protective gloves and eye
protection.
6. DO NOT ATTEMPT TO REFILL EMPTY CARTRIDGES.
The Purasan is a U. S. Coast Guard Certified Type I Marine Sanitation Device for use on inspected and
uninspected vessels 65 feet and under. It must be operated within areas that are not declared a Federal No
Discharge Zone (NDZ) by the U.S. Environmental Protection Agency (EPA). This is applicable for all U.S.
territorial waters inside the three mile limit. Other countries - check with local authorities.
The Purasan is designed for recreational use and accommodates most marine toilets it can be used with one or,
in some cases, two toilets. The Purasan is available in 12, 24 or 32 V DC.
The system consists of a Treatment tank, Tablet dispenser and Switch panel with cable. A portion of incoming
water passes over the halogen tablets creating a solution that is then dispensed into the treatment tank and mixes
with the macerated waste sanitizing it for discharge.
1-800-352-5630
1
Download from Www.Somanuals.com. All Manuals Search And Download.
Use ONLY Purasan Tablets.
DO NOT add any other chemicals or cleaning
products to the toilet or the treatment system.
Raritan C.P. - Cleans Potties and R.C. Raritan
Concentrate are the only factory-recognized cleaning
products that may be used in the toilet.
MAINTENANCE
WARNING: Read and understand all safety
instructions (including Material Safety Data
sheet) for handling Purasan Tablets before
performing any work on the Purasan.
Recommended Visual Inspection
INSTALLING TABLET CARTRIDGE
√ Tablet level in cartridge monthly
√ Tubes to and from dispenser are unobstructed
√ Tubes to treatment tank are unobstructed
Replace tablet cartridge only when completely empty.
Clean or replace tubes if any obstruction is found.
REPLACING TABLET CARTRIDGE
(#41-135)
CAUTION: Tablet dispenser may be under pres-
sure. Open lid SLOWLY
Remove used tablet cartridge -
1. With adequate ventilation available - Unscrew
tablet dispenser lid and lift out used tablet car-
tridge.
2. Rinse thoroughly with water to remove any re-
sidual tablet particles.
3. Clean plug assembly
CAUTION: Never dispose of tablets in a dry state
refer to MSDS for proper disposal.
4. Dispose of empty cartridge with other recyclable
plastics.
Loading new tablet cartridge in dispenser
1. Hold new tablet cartridge over tablet dispenser
with large end down. Remove tablet cartridge cap
and allow any loose tablet particles to drop into
the tablet dispenser. Slide tablet cartridge down
into tablet dispenser.
2. Cut nipple off top of tablet cartridge to create
an air hole.
3. Replace lid on tablet dispenser.
CLEANING: Do not add any other chemicals or
cleaning products to the toilet or the treatment system.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Tablet Dispenser
1. Close flow metering clamp and disconnect power
to water solenoid, if used, to prevent intake wa-
ter from entering tablet dispenser.
Close
Remove
and drain
2. Flush toilet and activate treatment cycle several
times to leave just water in tank.
3. Carefully remove small tube from white “T”
fitting or check valve from water solenoid valve.
Drain tube into a clean plastic container.
step 1
4. Carefully remove the small tube at the bottom of
the black “T” fitting. Drain tube into a clean plas-
tic container.
step 3
5. Connect Tube removed in step 3 to black “T”
fitting
Remove
and drain
6a. White “T’ fitting:
Connect tube removed in step 4 to white “T”
6b. Water Solenoid Valve
Connect
tube
plug tube removed in step 4
shut off water to valve
removed
in step 3
step 4
drain water from valve, hoses and strainer
7. Take solution collected in plastic container and
pour into toilet bowl. Rinse container and dis-
pose of properly.
Connect tube
removed in step 4
step 5
8. Flush toilet several more times to dilute solution
and clear it from system.
Treatment Unit
WARNING: DO NOT use anti-freeze of any kind
to winterize the Purasan system.
1. Turn off power and disconnect wires to Purasan
step 6a
plug tube
removed in
step 4
2. Close seacocks.
3. Slowly open crossover plug
Caution: Open plug slowly if treatment tank is at
the lowest point water will spill out
step 6b
crossover plug
4. Using a pump, remove water from both sides of
the treatment tank through crossover cap.
5. Disconnect and drain hoses.
Winterizing the Toilet - Follow the instructions in
the Owner’s Manual for that particular toilet.
IMPORTANT: If toilet requires anti-freeze or other
chemicals for winterizing, DO NOT allow these
chemicals to enter the Purasan system.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Recommissioning
IMPORTANT:
Do not load Tablet Cartridge into Dispenser until system is
powered and operational.
Do Not Operate Purasan until Treatment Unit is filled with
water.
Treatment Tank
1. Reconnect hoses and open seacocks.
2. Reconnect wires and turn power on.
NOTE: Purasan treatment tank must be full before activating a cycle.
IMPORTANT: Do Not connect Tablet Dispenser at this time.
3. Fill the treatment tank:
• Single button operation - Remove crossover plug from
Treatment Unit and fill with a minimum of three gallons of
water, replace crossover plug and O-ring.
• Independent operation - flush toilet allowing three gallons of
water to pass into Purasan
4. Turn on power to Purasan.
5. Check for leaks.
Reconnecting the Tablet Dispenser
IMPORTANT
• Make sure everything is working properly before proceeding.
• These instructions are the reverse operation outlined in winterizing
the Tablet Dispenser, steps 3 through 6.
1. Remove tube from the bottom of the black “T” fitting and re-
attach to the white “T” fitting or solenoid valve.
2. Reconnect hose on tank to the black “T” fitting on dispenser.
START UP
1. Remove Crossover Cap from treatment unit tower. Pour 3
gallons (11.5 liters) of water into Treatment Unit. Replace
Crossover Cap.
2. Turn on power to unit.
3. Fill toilet bowl half full of water before beginning.
4. Close metering clamp completely, then open slightly.
5. Flush toilet. Check water level in Tablet Dispenser during flush
cycle. Water level should rise to water line marked on Tablet
Dispenser while toilet is flushed, then drain out.
6. Adjust clamp until water reaches the line; opening clamp allows
more water into Tablet Dispenser. Flush toilet each time clamp
adjustment is changed to be sure water continues to be at the
proper level.
7. Load Tablet Cartridge.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
U.S.C.G. Type I MSD Certification #159.015/106/0
Maximum Roll/Pitch Angle: 30°
Maximum Temperature Exposure: 120° F (49° C)
Maximum Total Flush Volume: 1.5 gallons/flush (5.7 liters/flush)
Water - fresh, salt or brackish
NOTES: for Wiring
1.
2.
Distances are from source to unit and back to source.
Recommended conductor wire minimum AWG (mm2) for 3% voltage drop.
Recommended conductor sizes are based on 105oC rated insulation.
Refer to ABYC Standards for other insulation ratings.
3.
Recommended Wire and Fuse/Circuit Breaker Size
Units
Circuit
Amp. draw
@ nominal
voltage
Voltage Breaker/fuse
size (amps)
10
15
20
25
30
40
50
feet
feet
feet
feet
feet
feet
feet
12 VDC
24 VDC
32 VDC
20
15
15
10
8
12 AWG 12 AWG 10 AWG 10 AWG 10 AWG 8 AWG
6 AWG
14 AWG 14 AWG 14 AWG 12 AWG 12 AWG 10 AWG 10 AWG
14 AWG 14 AWG 14 AWG 14 AWG 14 AWG 12 AWG 12 AWG
8
CONVERSIONS
Wire - AWG to mm2
Fuse Specifications
AWG 16
14
12
10
8
6
4
2
12 VDC
Fuse type
24 VDC
Fuse type
32 VDC
Fuse type
mm2
1.5
2.5
4.0
6.0
10.0 16.0 25.0 35.0
Maximum amperage Maximum amperage Maximum amperage
part number
part number
part number
Feet to Meters
MDL 6 1/4
5 amp draw
32-218
MDL 6 1/4
4 amp draw
32-218
MDL 5
4 amp draw
34-218
FUSE 1 (F1)
Mixer Motor
Feet
10
15
20
25
30
40
50
MDL 12
5 amp draw
42-220
MDL 6 1/4
4 amp draw
32-218
MDL 5
4 amp draw
34-218
FUSE 2 (F2)
Macerator Motor
Meter 3.1
4.6
6.1
7.6
9.2
12.2 15.2
SWITCH PANEL
DIMENSIONS
TREATMENT UNIT DIMENSIONS
TABLET DISPENSER
DIMENSIONS
7 ¼”
(18.4cm)
2 ¼”
(5.7cm)
6” (15.2cm)
Diameter
3 3/8”
3 ¾”
c/c
(8.6cm)
(9.5cm)
9 ¾”
(24.8cm)
Width:
Depth:
16" (40.6cm)
8 ¾" (22.3cm)
6
Download from Www.Somanuals.com. All Manuals Search And Download.
MOUNTING
Treatment Tank
Treatment Unit Mounting
WARNING: DO NOT locate in an area where
ambient temperature exceeds 120o F (49o C).
1. Locate top of treatment tank at or below
discharge of toilet and within six feet (1.5 m).
Note: If mounting treatment tank higher
than discharge. Contact Raritan
2. Make and secure mounting frame to flat
surface.
3. Secure tank to frame using 3/4" (1.9 cm)
mounting straps.
Crossover Plug
E
INTAK
m)
Mounti
Straps
not
Note: Placing a 3/8" (.9 cm) rubber pad under tank
will help to reduce vibration and noise.
include
7"
(17.8 cm)
Mo
Switch Panel
Note: Cable supplied is 12 feet.
1. Locate in head compartment where indicator
lights will be visible.
2. Using template provided, mark the cutout for
the panel.
3. Route cable between Switch Panel and
Purasan Treatment Unit.
4. Attach wires per wiring section to back of
switch panel.
5. Mount panel using 4 screws. Apply a bead of
nonpermanent sealant around rear edges of
panel if located in shower area.
Purasan Tablet Dispenser
15” or
higher
1. Locate bottom of Tablet Dispenser a minimum
of 15” (38 cm) above the top surface of the
Treatment Unit or top of vented loop (if used).
2. Locate Tablet Dispenser with a minimum of
8” (20 cm) of clearance for removing the lid
and periodically changing the cartridge.
Note: Supplied tubing to connect intake water
to dispenser is 6 feet (1.8 m) in length.
3. Attach to wall or suitable structure using 1/4”
(6 mm) bolts.
IMPORTANT: Do Not load Tablet Cartridge
into Tablet Dispenser at this time. Load
Tablet Cartridge after completing Start Up
procedure.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Raw Water Toilets -
1. Turn off power to toilet.
2. Close intake and discharge seacocks and
drain water from toilet system.
Raw water toilets
Bowl elbow with restrictor
3. Disconnect intake hose from bowl elbow.
4. Remove existing bowl elbow and install new
bowl elbow supplied with Purasan.
5. Insert the “T” fitting in the hose between the
output of the pump and the new bowl elbow.
Fresh Water/Manual Toilets -
Hose clamps
T Fitting
Water supply from
pressure side of pump
1. Connect reducer bushing to incoming side of
solenoid valve.
2. Connect 1/4” nipple fitting to outgoing side
of solenoid valve.
3. Install supplied strainer between water source
and solenoid
4. Check valve MUST be installed between so-
lenoid valve and tablet dispenser.
Pressurized fresh water toilets
water
solenoid
Check
valve
adapter
Tubing with
clamps
restrictor
fitting
WARNING:
Discharge from
• All installations made below the waterline MUST
be protected by installing vented loops
• Always double clamp fittings below waterline
• Do Not use metal fittings
rasan to thru-hull
NOTE: Use PTFE tape or nonpermanent thread
sealing compound on threaded PVC fittings and
connections. Avoid low areas in hose that would
allow untreated waste to collect.
INTAKE
1. Connect discharge of toilet to one intake port.
2. Insert plug or second toilet discharge into other
intake port.
Discharge from toilet to either side
- Install plug in side not used
3. Determine position and glue discharge elbow to
top of tank using PVC cement.
4. Connect discharge hose from elbow to thru hull
fitting.
IMPORTANT: Be certain that the discharge
elbow is in the correct position before gluing.
Tablet Dispenser
IMPORTANT: 1/4” Tube to treatment tank must
run downward with no loops, kinks or upward
turns.
1. Connect 1/4” tubing from the black “T” fitting at
the dispenser (red cap) to the check valve on the
top of the treatment unit.
15 minimum
to top of tank
or vented loop
(if used)
2. Slide flow metering clamp onto remaining tube
3. Install tube with flow metering clamp from White
“T” (in raw water installation) or Solenoid valve
(in pressurized freshwater installation) to bottom
of tablet dispenser (black cap).
8
Download from Www.Somanuals.com. All Manuals Search And Download.
WIRING
Purasan Treatment Unit
WARNING: Hazard of Shock and Fire
•
Always use proper wire, wire connectors
and fuse/circuit breaker. See Specification
Chart.
+
_
•
•
Secure wire properly.
Do not connect other appliances to Purasan
circuit.
Control Box
Fuse/breaker per
specifications
•
•
Make sure power is off before proceeding.
Improper wiring can damage the Circuit
Board and void warranty.
_
+
Battery
NOTE: Raritan recommends that the electric
toilet be installed for single touch operation.
Treatment Unit
1. Determine proper wire size from wire chart on
specifications page.
2. Run supply wire from source to Positive (POS)
and Negative (NEG) terminals on Treatment tank.
3. Fuse or circuit breaker must be installed between
source and Purasan on positive wire.
Control
Switch Panel
1. Connect cable from Switch Panel to Circuit
Board as follows:
S1 to S1 - red wire
S2 to S2 - orange wire
L1 to L1 - green wire
L2 to L2 - white wire
S4 to S4 - black wire
WIRE CONNECTIONS - Not all connections will
be made, depends on installation options chosen
- IN Battery Negative
S4 Black to switch panel
S6 Orange to switch panel #2
S2 Orange to switch panel #1
S3 (+) external out
S5 Auxiliary switch
F1 - Mixer
H1 (-) to solenoid (Toilet #1)
L2 White to switch panel (s)
M2+ (+) to mixer motor
L1 Green to switch panel (s)
M1+ (+) to macerator motor
S1 Red to switchpanel(s)
+IN Battery Positive
F2 - Macerator
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Flushing Option #1:
"Push to Cycle" button activates both the toilet
and treatment cycle.
TYPICAL INSTALLATION - Flushing Option #1
“Push to Cycle” also activates toilet -
single toilet installation
Note: Toilet flush time is set at 10 seconds, after
initial 10 seconds holding the button down will
momentarily flush the toilet.
Small post on
CDS to H1
jumper wire
with
1. Mount Switch Panel near toilet.
CAUTION: Use only the Raritan #CDS (fail-
ure to do so will damage to the Control
Board, voiding warranty).
3 amp fuse
2. Run 16 ga. wire from terminal H1 on Circuit
Board to one of the small relay terminals.
CDS
To toilet
positive (+)
3. Run a wire from the other small relay terminal
to the Positive supply from battery with a 3 amp
fuse.
Battery
TYPICAL INSTALLATION - Flushing Option #2
“Push Button” also activates Purasan -
single toilet installation
Flushing Option #2:
Toilet Push Button -
Small post on CDS
PBS
Flushing toilet will activate treatment cycle.
to S2 and PBS
Note: Toilet may be flushed as often as necessary,
do not exceed recommended flush volume.
3 amp
Fuse
1. Mount Switch Panel near toilet.
CAUTION: Use only the Raritan #CDS (failure
to do so will damage to the Control Board,
voiding warranty).
CDS
To toilet
positive (+)
2. Run 16 ga. wire from small relay terminal to S2
on Circuit board and one post of the PBS (push
button switch)
Battery
TYPICAL INSTALLATION - freshwater, dual
installation and manual toilets
Solenoid required to supply water to tablet
dispenser
Freshwater, dual installation and manual
toilets:
Solenoid valve supplies water to
tablet dispenser -
1. Mount Switch Panel near toilet.
2. Run 16 ga. wire from battery positive to one of
the wires on the solenoid with 3 amp fuse in line.
Battery
3. Run 16 ga. wire from wire on solenoid not used
to H1 on Purasan Circuit Board.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
TROUBLESHOOTING
No Water to tablet dispenser
WARNING: After the tablet dispenser
has had water added, it contains a very
strong halogen solution. Always wear
protective gloves and ventilate well to
work on tablet dispenser. Before doing
any maintenance or repairs, follow
WINTERIZING/STORAGE procedures
• Clogged check valve (T-fitting #41-200)
Clean or replace check valve
• Clogged intake fitting to dispenser
Clean plug assembly
• Intake pump or solenoid valve not functioning
Check pump or solenoid for proper operation
• Intake tubing clogged
clean or replace intake tubing
• Bowl Elbow was not changed
install bowl elbow with restrictor, supplied
TABLET DISPENSER
CAUTION: Tablet Dispenser may be
under pressure open lid slowly to relieve
pressure.
Overflow or water level too high in dispenser
• Metering clamp not adjusted properly
Adjust clamp (see start up)
• Clogged discharge fitting in tablet dispenser
Clean plug assembly
• Clogged Check valve (41-111)
Clean or replace check valve
• Tablet dispenser not mounted correctly
Tablet dispenser must be 15” or higher from top of
vented loop or treatment lid
Nothing happens when button is pushed
• Fuses blown
Check fuses
• Switch panel bad
Replace switch panel
11
Download from Www.Somanuals.com. All Manuals Search And Download.
41-100
32
43
45
6
49
31
29
42
22
47
56
43
64
63
28
21
50
23
53
55
7
8
18
17
23
23
10
12
Download from Www.Somanuals.com. All Manuals Search And Download.
PURASAN PARTS LIST
Item Part #
Description
Item Part #
Description
50 41-110
Vent Kit for Tablet Dispenser (Incl. #53,
54, & 55)
#14 Brass Flat Washer (4)
1
1
1
2
3
6
7
8
9
32-102AW Mixer Motor 2 1/2" Dia. 12 V DC
33-102AW Mixer Motor 2 1/2" Dia. 24 V DC
34-102AW Mixer Motor 2 1/2" Dia. 32 V DC
51 M31
52 M30
41-100
1/4"-20 Brass Nut (4)
31-121
31-120
31-106
31-103
31-113-3
31-109
Hose Fitting (2)
Discharge Elbow 90o
Tablet Dispenser Complete(less cartridge)
T-Fitting (Incl. #33, 34, 37 &38)
Treatment Unit Complete 12 V DC
Treatment Unit Complete 24 V DC
Treatment Unit Complete 32 V DC
Continuous Duty Solenoid
41-200
Cover Hold down Bolt, 10-32 x 7/8", S/S (18)
Motor Shaft Bushing (2)
Motor Hold down Bolt, 10-32x1", S/S (4)
Mixer Impeller
42-1000
43-1000
44-1000
CDS*
10 31-110-1
11 31-110-2
12 31-114
13 31-115
14 31-122
15 41-102
16 31-112
17 31-108
18 31-107
19 31-101W
21 31-102
Impeller Bolt, 12-24 x 5/8", S/S (2)
Impeller Lock Washer, #12, S/S (2)
Cover Hold down Nut, 10-32 (18)
Treatment Tank
Intake Plug
Tank Divider
Cover Gasket
Macerator Set Screw
Macerator Impeller
Treatment Cover
PSTDC03 Purasan Dual Control
53 41-111
54 31-305
55 41-106
56 31-325
57 31-319
58 41-111
61 31-102-3
62 31-102-4
63 31-102-1
64 31-102-2
Check Valve
2" (5cm) long 1/4" I.D. Tubing
"T" Fitting
Adapter
3/8” x 1 3/4” Tubing
Check Valve
Mixer seal washer
Mixer retaining ring
Macerator seal washer
Macerator retaining ring
Motor Shaft Seal (2)
22 33-101AW Macerator Motor 12 V DC
22 34-101AW Macerator Motor 24, 32 V DC
Pressurized Kit Part # 41-254
23 31-305
24 41-115
25 31-104C
26 31-105
27 41-125
28 41-130
29 41-135
1/4" I.D. Tubing
Union Tee 1/4" Barbed
Crossover Plug
O-Ring
Bottom Plug Assy.
Dispenser Body (PVC)
Cartridge (refill) PURASAN Tablets
Note: Cartridge must be shipped in a
separate container, call 856-825-4900.
Slinger (2)
"O" Ring
Dispenser Cap
Outlet Adapter
O Ring
T-Check Valve Body
Check Valve Assy.
T-Check Valve, Complete (33,34,37,38)
Switch Panel Complete
Control Cable
190601
31-305
41-111
41-261
41-280
PLA14
PLA15
PLA16
In-line Strainer
1/4” tubing
Cartridge check valve
fitting with restrictor
hose clamps
adapter: 1/2” MNPT X 3/4”
adapter: 3/8” x 1/4”
adapter: female 1/2” x 1/4”
30 31-101-2
31 RWS5
32 41-131
33 31-307D1
34 31-307E
37 31-307D
38 41-205
41-200
39 41-350
40 41-355
41 31-304C
42 32-218
42-220
Pump Kit Part # 41-253
31-305
41-200
41-260
PLA15
Tubing
T-fitting
Bowl elbow with restrictor
Adapter: 3/8” x 1/4”
Flow Metering Clamp
Fuse: F1, MDL 6 1/4 (12 V DC, 1 Req’d.)
Fuse: F2, MDL 12 (12 V DC, 1 Req’d.)
Fuse: F1/F2, MDL 6 1/4 (24 V DC, 2 Req’d)
Fuse: F1/F2, MDL 5 (32 V DC, 2 Req’d.)
Control Box w/Cover and Screws
Standoff (4)
Circuit Board Mounting Screw (4)
Circuit Board, 12 V DC
Circuit Board, 24 V DC
Circuit Board. 32 V DC
Electronic Control Complete*, 12 V DC
Electronic Control*, 24 V DC
Electronic Control*, 32 V DC
*Incl. #43, 45, 47, 49
32-218
34-218
43 41-301
45 F41-312
47 CH46VT
49 42-303
43-303
44-303
42-300
43-300
44-300
* Specify Voltage (12, 24 and 32 VDC)
13
Download from Www.Somanuals.com. All Manuals Search And Download.
IMPORTANT:
DUAL INSTALLATION -
“Push Button” also activates Purasan -
Dual toilet installations require either
independant operation of toilet and
treatment cycle or activation from the
toilet of the treatment cycle.
Small post on CDS
to S6 and PBS for
second toilet
Dual installations require only one
dispenser, water to fill dispenser MUST
be supplied using a freshwater solenoid.
PBS
3 amp
Fuse
Small post on CDS
to S2 and PBS
WIRING
Switch Panel (2nd one)
1. Connect cable from Switch Panel to Circuit
Board as follows:
CDS
To toilet
positive (+)
S1 to S1 - red wire
S2 to S6 - orange wire
L1 to L1 - green wire
L2 to L2 - white wire
S4 to S4 - black wire
Battery
Freshwater Solenoid valve wiring
Toilet activation starts treatment cycle
Flushing toilet will activate treatment cycle.
Note: Toilet may be flushed as often as
necessary, do not exceed recommended flush
volume.
1. Mount Switch Panel near toilet.
CAUTION: Use only the Raritan #CDS
(failure to do so will damage to the Con-
trol Board, voiding warranty).
Battery
2. Run 16 ga. wire from small relay terminal
to S2 on Circuit board and one post of the
PBS (push button switch)
3. Run 16 ga. wire from small realy terminal
on second solenoid to S6 on Circuit board
and one post of the second PBS.
4. Wire freshwater solenoid see below.
Freshwater Solenoid valve wiring
1. Run 16 ga. wire from battery positive to one
of the wires on the solenoid with 3 amp fuse
in line.
2. Run 16 ga. wire from wire on solenoid not
used to H1 on Purasan Circuit Board.
PLUMBING
Follow installation instructions on page 8 and
connect second toilet to second intake port
14
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTE:
Discharge of raw, untreated sewage is prohibited in all U.S. waters inside the three mile limit except in the Gulf of Mexico
where the limit is nine miles. "Y" valves, if installed, must direct toilet discharge to a U.S.C.G. approved treatment
system or holding tank and must be secured in that position while inside the three-mile limit.
The EPAstandards state that in freshwater lakes, freshwater reservoirs or other freshwater impoundments whose inlets or outlets
are such to prevent the ingress or egress by vessel traffic subject to this regulation, or in rivers not capable of navigation by
interstate vessel traffic subject to this regulation, marine sanitation devices certified by the U.S. Coast Guard installed on all
vessels shall be designed and operated to prevent the overboard discharge of sewage, treated or untreated, or any waste derived
from sewage. The EPA standards further state that this shall not be construed to prohibit the carriage of Coast Guard-certified
flow-through treatment devices which have been secured so as to prevent such discharges. They also state that waters where a
Coast Guard-certified marine sanitation device permitting discharge is allowed including coastal water estuaries, the Great
Lakes and interconnected waterways, freshwater lakes and impoundments accessible through locks, and other flowing waters
that are navigable interstate by vessels subject to this regulation (40 CFR 140.3)
15
Download from Www.Somanuals.com. All Manuals Search And Download.
2 1/4"
(5.7cm)
l
ss
Template for
Switch Panel
CUT OUT
HATCHED
AREA
k (2)
unting
es
3 3/4"
9.5cm
Of
Panel
LIMITED WARRANTY
Raritan Engineering Company warrants to the original purchaser that this product is free of defects in materials or workmanship for a period of one year
from the products date of purchase. Should this product prove defective by reason of improper workmanship and/or materials within the warranty period
, Raritan shall, at its sole option, repair or replace the product.
1. TO OBTAIN WARRANTY SERVICE, Consumer must deliver the product prepaid, together with a detailed description of the problem, to Raritan at 530
Orange St., Millville, N.J. 08332, or 3101 SW 2nd Ave. Ft. Lauderdale, FL 33315. When requesting warranty service, purchaser must present a sales slip
orotherdocumentwhichestablishesproofofpurchase.THERETURNOFTHEOWNERREGISTRATIONCARDISNOTACONDITIONPRECEDENT
OF WARRANTY COVERAGE. However, please complete and return the owner Registration Card so that Raritan can contact you should a question of
safety arise which could affect you.
2. THIS WARRANTY DOES NOT COVER defects caused by modifications, alterations, repairs or service of this product by anyone other than Raritan;
defects in materials or workmanship supplied by others in the process of installation of this product; defects caused by installation of this product other than
in accordance with the manufacturers recommended installation instructions or standard industry procedures; physical abuse to, or misuse of, this product.
This warranty also does not cover damages to equipment caused by fire, flood, external water, excessive corrosion or Act of God.
3. ANY EXPRESS WARRANTY NOT PROVIDED HEREIN, AND ANY REMEDY FOR BREACH OF CONTRACT WHICH BUT FOR THIS
PROVISION MIGHT ARISE BY IMPLICATION OR OPERATION OF LAW, IS HEREBY EXCLUDED AND DISCLAIMED. ALL IMPLIED
WARRANTIES SUCH AS THOSE OF MERCHANTABILITY AND OF FITNESS FOR A PARTICULAR PURPOSE, IF APPLICABLE, AS WELL AS
ANY IMPLIED WARRANTIES WHICH MIGHT ARISE BY IMPLICATION OF LAW, ARE EXPRESSLY LIMITED TO A TERM OF ONE YEAR.
SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG A LIMITED WARRANTY LASTS, SO THE ABOVE LIMITATION MAY NOT
APPLY TO YOU.
4. UNDER NO CIRCUMSTANCES SHALL RARITAN BE LIABLE TO PURCHASER OR ANY OTHER PERSONS FOR ANY SPECIAL OR
CONSEQUENTIAL DAMAGES, WHETHER ARISING OUT OF BREACH OF WARRANTY, BREACH OF CONTRACT, OR OTHERWISE. SOME
STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE
LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU.
5. No other person or entity is authorized to make any express warranty, promise or affirmation of fact or to assume any other liability on behalf of Raritan
in connection with its products except as specifically set forth in this warranty.
6. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
530 Orange Street, Millville, NJ 08332 USA
Telephone: 856-825-4900
Southern Office and Plant:
FAX: 856-825-4409
3101 SW Second Avenue, Fort Lauderdale, FL 33315 USA
Telephone: 954-525-0378 FAX: 954-764-4370
L405 0911kgs
Specifications Subject to Change Without Notice
Printed in U.S.A.
16
Download from Www.Somanuals.com. All Manuals Search And Download.
|