Raritan Engineering Indoor Furnishings SeaEra Toilets User Guide |
SeaEra Toilet
OPERATION, MAINTENANCE AND INSTALLATION INSTRUCTIONS
THE FOLLOWING ARE CAUTIONARY STATEMENTS THAT MUST BE READ AND
FOLLOWED DURING BOTH INSTALLATION AND OPERATION.
WARNING: Raritan Engineering Company, Inc. recommends that a qualified person or electrician install this
product. Equipment damage, injury to personnel or death could result from improper installation.
Raritan Engineering Company, Inc. accepts no responsibility or liability for damage to equipment,
injuryordeathtopersonnelthatmayresultfromimproperinstallationoroperationofthisproduct.
WARNING: HAZARD OF SHOCK OR FIRE
Always use recommended fuse, circuit breaker and wire size.
Motors used with this product are “Ignition Protected”. They are not however, explosion-
proof as defined in 46CFR 110.15-65(e), Subchapter J-Electrical Engineering.
DO NOT run continuously for more than 30 seconds.
WARNING: HAZARD OF FLOODING - Always shut off seacock(s) before leaving the boat unattended.
Double clamp all below waterline hose fittings and check frequently for integrity.
Pressurized
Freshwater Model
Sea Water Model
(Remote Pump)
Sea Water Model
(Integral Pump)
The SeaEra toilet is a powerful centrifugal macerating toilet that thoroughly breaks down waste.
1-800-352-5630
Download from Www.Somanuals.com. All Manuals Search And Download.
Cleaning Instructions
IMPORTANT: Do not use cleaners that contain
ammonia, ethyl acetate, phosphoric acid or
concentrated chlorine bleach. These may cause
damage to the toilet.
Using C.P. a bio-enzymatic toilet bowl cleaner
(available from Raritan Engineering) will keep the
bowl clean and fresh smelling.
Recommend Visual Inspection
✔ For leaks at toilet and hose connections
✔ Hose clamps
✔ Condition of hoses
✔ Seacocks
✔ Condition of wires and connections
✔ In-Line Strainer (if you have one)
Cleaning In-Line Strainer
(Sea Water Models only)
Clean Gasket
and Gasket
Contact Surfaces
Thoroughly
1. Shut off intake seacock.
2. Unscrew bowl.
Filter
3. Remove filter.
4. Clean bowl and filter with a clean cloth.
5. Clean gasket and gasket contact surfaces
thoroughly.
Bowl
Unscrew
Tighten
6. Replace gasket, filter and bowl.
7. Open seacock.
8. Check for leaks.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
IMPORTANT
•
Improper winter lay up is a major cause of
marine toilet failure.
•
•
Use only nontoxic antifreeze.
Flush toilet several times to clear waste
from system.
•
•
Dispose of all antifreeze in accordance with
local and federal regulations.
Winterize holding tanks, plumbing,
treatment systems (MSD’s), etc.
independently following manufacturer’s
instructions.
Pressurized Freshwater Models
Pressurized Freshwater Model
Parts Required
•
1" (25mm) or 1 1/2" (38mm) I.D.discharge
hose, approximately 3 feet (1m) long
Nontoxic
Antifreeze
•
•
Two buckets
Nontoxic antifreeze approximately 1 quart
(1 liter)
Steps
1. Close discharge seacock.
2. Shut off intake water at source.
3. Turn off power to unit.
4. Disconnect and drain discharge hose.
5. Disconnect intake hoses from vacuum breaker
and place in one of the buckets.
6. Connect hose to toilet’s discharge and place
in other bucket.
7. Pour antifreeze in bowl.
8. Turn on power to unit and flush until antifreeze
is removed from the bowl and water is drained
from the solenoid and hose.
9. Disconnect power to toilet.
10. Reconnect intake hoses to vacuum breaker.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Integral and Remote Intake Pump Models
Parts Required
3/4" (19mm) I.D. intake hose approximately 3 feet
(1m) long.
Sea Water Model (Integral Pump)
Nontoxic
Antifreeze
1" (25mm) or 1 1/2" (38mm) I.D. discharge hose
approximately 3 feet (1m) long.
Two buckets
Nontoxic antifreeze approximately 1 quart (1 liter)
Steps
1. Close the intake and discharge seacocks.
2. Turn off power to unit.
3. Disconnect and drain intake hose, discharge hose
and In-Line Strainer.
4. Connect short hoses to toilet’s intake and
discharge.
5. Place one bucket under hose connected to toilet’s
discharge.
Sea Water Model (Remote Pump)
Nontoxic
Antifreeze
6. Pour nontoxic antifreeze in other bucket.
7. Place hose connected to intake pump into bucket
with antifreeze.
8. Turn on power to unit and flush toilet until
antifreeze begins to be discharged from toilet.
9. Disconnect power to toilet.
RECOMMISSIONING
1. Using the buckets, hoses and approximately one
gallon (3.8 liters) of clean fresh water, flush
antifreeze out of the toilet (see Winterizing).
Dispose of antifreeze in accordance with local
and federal regulations.
2. Reconnect the intake and discharge hoses and
open both seacocks and water source valve.
3. Check all connections for leaks with several test
flushes.
SYSTEM START-UP
1. Open seacock(s).
NOTE: Pressurized freshwater models; open water
source valve.
2. Turn on power to toilet.
3. Flush toilet per Operation Instructions.
4. Check for leaks.
IMPORTANT: If toilet does not flush properly
or if water does not enter the bowl within 10
seconds, refer to Troubleshooting.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Pressurized Freshwater or Remote SeaWater Model
Integral SeaWater Model
14 3/8" (36.5cm) Household
19 3/4" (52.1cm) Household
17 1/2" (44.5cm) Marine
19 3/4"(50.2cm) Household
16 3/4"(42.6cm) Marine
13" (33cm) Marine
14 7/8"
(37.8cm)
Household
14 1/2"
(36.8cm)
Marine
13 3/8" (34cm)
6 5/8" (16.8cm)
11 1/8" (28.3cm)
Plumbing
Maximum suction of Intake pump
4 Ft. (1.2m) from Intake Pump.
(Maximum height above waterline)
CONVERSIONS
Wire - AWG to mm2
Maximum height of discharge vented loop 6 Ft. (1.8m) from base of toilet.
AWG 16
14
12
10
8
6
4
2
minimum flow rate of 3 gpm (11.3 liters).
Pressurized water source requirements
minimum pressure of 5 psi (34.5 kPa).
mm2
1.5
2.5
4.0
6.0
10.0 16.0 25.0 35.0
NOTES: for Wiring
1.
Distances are from source to unit and back to source.
Feet to Meters
Distance from power source to remote intake pump MUST be included when
determining total distance.Same wire size MUST be used for lower base and
remote intake pump.
Feet
10
15
20
25
30
40
50
2.
Meter 3.1
4.6
6.1
7.6
9.2
12.2 15.2
3.
4.
5.
Recommended conductor wire minimum AWG (mm2) for 3% voltage drop.
Recommended conductor sizes are based on 105oC rated insulation.
Refer to ABYC Standards for other insulation ratings.
For 120/240 VAC units use 24VDC specifications from transformer to unit.
Sea Water Model - Recommended Wire and Fuse/Circuit Breaker Size
Integral Pump
and lower base
Remote Pump
and lower base
Remote Pump
only
Circuit
Units
Voltage
15
feet
20
feet
30
feet
40
feet
50
feet
Breaker/fuse
size (amps)
Amp. draw
@ nominal
voltage
Amp. draw
@ nominal
voltage
Amp. draw
@ nominal
voltage
12 VDC
24 VDC
32 VDC
25
15
15
18
10
23
12.5
9
10
5
10 AWG 8 AWG
6 AWG
6 AWG
4 AWG
14 AWG 14 AWG 12 AWG 10 AWG 10 AWG
14 AWG 14 AWG 14 AWG 12 AWG 12 AWG
7.5
4
Pressurized Freshwater Model - Recommended Wire and Fuse/Circuit Breaker Size
Circuit
Breaker/fuse
size (amps)
Amp. draw
@ nominal
voltage
10 feet
15 feet
20 feet
30 feet
40 feet
50 feet
Units
Voltage
12 VDC
Lower Base
12 AWG 10 AWG 10 AWG 8 AWG
6 AWG
6 AWG
6 AWG
25
15
15
13
7.5
5
24 VDC
Lower Base
14 AWG 12 AWG 10 AWG 10 AWG 8 AWG
32 VDC
Lower Base
16 AWG 16 AWG 14 AWG 12 AWG 10 AWG 10 AWG
12, 24, and 32 VDC
Water Solenoid
Valve
16 AWG 16 AWG 16 AWG 16 AWG 16 AWG 16 AWG
3
2
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Parts Included
Additional Parts Required
•
Four stainless steel mounting bolts or lag
screws (minimum 1/4" [6mm]) and washers
1" (25mm) or 1 1/2" (38mm) I.D. discharge hose
3/4" (19mm) I.D. reinforced intake hose
3/4" (19mm) and 1" (25mm) or 1 1/2" (38mm)
hose clamps (two for each connection below
waterline)
Wire
Terminals
Fuse/circuit breaker
All Complete Toilets
Toilet Bowl
Seat and Cover
Lower Base Assembly
Motor Cover
Push Button Switch
•
•
•
Sea Water Model
•
•
•
3/4" Hose Barb - straight fitting (2)
3/4" Hose Barb - 90° fitting
Plug Fitting
In-Line Strainer with fittings
3/4" Stainless Steel Hose Clamps (2)
Pressurized Freshwater Models
Atmospheric Vacuum Breaker (PLAVB0-5)
Solenoid Valve with fittings
Solenoid Valve Mounting Bracket
Tools Required
•
•
•
•
•
•
•
•
5/16" nut driver
Wrench or screw driver
5/8" (16mm) drill bit
Bit for drilling mounting surface
Wire cutters
Wire terminal crimpers
Hose cutters
Tape measure
Mounting Toilet
Mounting surface must be flat and solid.
1. Install seat on toilet.
2. Remove motor cover.
3. Place toilet where it will be located.
Make sure there is room to route hoses.
Make sure seat will open properly.
4. Mark location of toilet base mounting holes
on mounting surface.
5. Drill holes for toilet mounting bolts/screws.
NOTE: Hole size will depend on type of bolt/
screws used (5/16" [8mm] size bolts/screws are
recommended).
6. Secure toilet to surface.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
90° Rotation of Toilet Bowl
Toilet bowl can be rotated 90° on the base, for
installing in confined locations.
NOTE: SeaEra Models with Integral Pump:
Replace existing hose from the intake pump to the
toilet bowl with a longer hose.
1. Determine which direction bowl is to be
mounted.
2. Remove hose at back of toilet (Sea Water
Model with Integral Pumps ONLY).
3. Remove four vinyl caps at the base of toilet
bowl.
4. Remove four nuts and shoulder washers.
5. Carefully remove toilet bowl from base.
6. Rotate toilet bowl to desired position.
7. Replace four shoulder washers, nuts and vinyl
caps.
NOTE: Tighten nuts carefully and evenly. Do
Not over tighten.
Mounting Push Button Switch
•
•
•
Mount Push Button Switch in an accessible
location.
Make certain wires can be routed to Push
Button Switch.
Wire terminals must have clearance when
installed.
1/4" Minimum clearance from terminals to any object
1. Drill 5/8" (16mm) hole.
2. Attach wires to Push Button Switch terminals
(see wiring section).
3. Install Push Button Switch through back of
mounting surface.
4. Install waterproof nut on Push Button Switch.
5. Secure in place with inner nut.
Inner Nut
Install the Warning Label (L322) where it can
be easily seen.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Mounting Water Solenoid Valve
(Pressurized Freshwater Models Only)
1. Locate valve on a solid flat surface in an area
that is dry and well ventilated.
2. Mark and drill holes for water solenoid mounting
bracket.
NOTE: Hole size will depend on type of bolts/screws
used (1/4" [6mm] size bolt/screws are recommended).
3. Mount bracket.
4. Install fittings provided (PLA7) on valve’s inlet
and outlet ports.
From
Pressurized
Freshwater
Source
5. Attach valve to bracket. hoses must be installed
according to flow markings on valve body.
PLA7
To inlet port of
IN
OUT
vacuum breaker
Mounting Atmospheric Vacuum Breaker
(Pressurized Freshwater Model only)
Min. 6”
(15.3 cm)
1. Install fittings as shown.
2. Locate mounting area that is a minimum of 6"
(15.3cm) above toilet.
3. Secure where top is in horizontal position.
Mounting In-Line Strainer
(Seawater Models Only)
Make sure strainer bowl is tight.
1. Locate strainer where it will be accessible.
2. Mark and drill mounting holes.
NOTE: Hole size will depend on type of bolts/screws
used (1/4" [6mm] size bolts/screws are
recommended).
3. Install fittings provided (PLA7) on strainer’s inlet
and outlet ports.
Flow Marking
NOTE: Use thread sealant.
4. Mount strainer. Hoses must be installed according
to flow marking on strainer top.
Mounting Remote Intake Pump
(Remote Pump Models Only)
1. Remote intake pump must be mounted on a
flat solid surface in an area that is dry and well
ventilated.
2. Mark and drill mounting holes.
NOTE: Hole size will depend on type of bolts/screws
used. (1/4" [6mm] size bolts/screws are
recommended).
3. Mount pump. Do not over tighten bolts.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Pressurized Freshwater Model
Installed AboveWaterline
PLUMBING
WARNING: Hazard of Flooding
Toilets mounted at or below the waterline
must have a vented loop installed in the
discharge line. The top of the vented loop
must be a minimum of 4" (10cm) above
the waterline at the boats greatest angle
of heel (see vented loop manufacturer’s
instructions).
Wa
Waterline
line
Sea Water Models must also have a vented
loop installed between the intake pump
and the toilet bowl.
SeaWater Model with Integral Pump
Installed BelowWaterline
Double clamp all below waterline
connections.
IMPORTANT
Discharge
Vented
Loop
Intake Vented
Loop
•
Fittings and 90° bends should be kept
to a minimum.
SeaEra
Toilet
•
In-Line Strainer must be installed on
Sea Water Models per Installation
Instructions. Failure to do so may void
Warranty.
Waterline
Lectra/San
In-Line
Strainer
Discharge
Seacock
Intake
Seacock
•
•
Discharging untreated sewage is
forbidden in all U. S. waters within the
three-mile limit.
Thru-hull fittings and seacocks must
be installed where they are easily
accessible.
Remote Intake Pump Model
Mounted AboveWaterline
Discharge
Vented
Loop
•
•
Use only quality reinforced hoses.
Secure all hoses properly.
ne
Discharge Lines
1. Connect quality sanitation hose 1"
(25mm) or 1 1/2" (38mm) I.D. to
discharge fitting on toilet.
2. Run hose to appropriate device (i.e.:
treatment system, holding tank, etc.).
1" (25mm)
Discharge Fitting
Hose
1 1/2" (38mm)
Discharge Fitting
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Intake Lines
Pressurized Freshwater Models
From Pressurized
Freshwater Source
(Shut Off Valve)
Install a shut off valve in intake line before water
solenoid valve.
1. Connect hose from shut off valve to inlet port
of water solenoid valve.
IN
NOTE: To avoid malfunction of water solenoid due
to debris in water, installation of Freshwater
Strainer (190601) is recommended.
2. Connect hose from outlet port of water solenoid
valve to inlet port of vacuum breaker.
OUT
To Inlet Port
of Vacuum
Breaker
3. Connect hose from outlet port of vacuum breaker
to bowl elbow.
Outlet Port
Inlet Port
NOTE: Vacuum breaker must be last mechanical
component before bowl elbow.
Outlet Port
Arrow
Sea Water Models
Intake pump fittings are interchangeable to allow
more flexibility during installation. Inlet ports are
located on either side of intake pump. Outlet port
(to toilet bowl) is at top of intake pump.
1. Slide fitting clips to open position.
2. Select inlet port to be used.
Inlet Ports
3. Install appropriate fittings into inlet and outlet
ports.
NOTE: The 90° fitting can be rotated 360°.
4. Install the plug fitting into unused inlet port.
Closed
Open
IMPORTANT: Be sure not to install plug fitting
into outlet port! Damage will occur!
To Bowl
5. Slide fitting clips back to closed position.
6. Connect hose from seacock to inlet port of
In-Line Strainer. Use hose clamp provided.
7. Connect hose from outlet port of In-Line
Strainer to inlet port of intake pump. Use hose
clamp provided.
Plug
From Strainer
IMPORTANT: Double clamp all below
waterline hose connections!
From
Seacock
8. Remote Pump Models Only: Connect hose
from outlet port of intake pump to bowl elbow
located on back of toilet bowl. (Integral pump
model is already connected).
To Intake
Pump
11
Download from Www.Somanuals.com. All Manuals Search And Download.
WIRING
Pressurized FreshwaterWiring
WARNING: Hazard of Shock and Fire
•
Always use proper wire, wire connectors
and fuse/circuit breaker. See Specification
Chart.
on
•
•
•
•
Secure wire properly.
3 Amp
Fuse
Do not connect appliances to toilet circuit.
Make sure power is off before proceeding.
Use proper wire terminals for all wire
connections.
Solenoid
Valve
se or
rcuit
1. Determine proper wire size by measuring
distance from:
aker
•
Power Source to push-button to toilet
motor and back to power source.
•
Remote pump units - also include distance
from power source for remote pump to
remote pump and back. Same wire must
be used for both lower base and remote
pump.
Remote PumpWiring
2. Select proper wire and fuse/circuit breaker size
from Specifications on Installation page.
Push Button
Switch
Black
NEG (-)
3. Install fuse/circuit breaker in positive line at
source.
4. Connect positive wire from fuse/circuit
breaker to Push Button Switch.
Fuse or
Circuit
Breaker
Orange
POS (+)
Black
NEG (-)
NEG POS
5. Connect wire from Push Button Switch to
orange wire on motor(s).
NOTE: Pressurized Freshwater Models; connect
wire from Push Button Switch to orange wire on
motor and from Push Button Switch to one of the
wires on water solenoid valve. The water solenoid
valve is not polarity sensitive.
Integral PumpWiring
6. Connect wire from battery negative or power
source ground buss to black wire (negative)
on motor(s).
Push Button
Switch
Fuse or
Circuit
Breaker
NOTE: Pressurized Freshwater Models; connect
remaining wire from water solenoid valve to
battery negative or power source ground buss.
Orange
POS (+)
NEG POS
Black
NEG (-)
12
Download from Www.Somanuals.com. All Manuals Search And Download.
TROUBLESHOOTING
WARNING: HAZARD OF ELECTRIC SHOCK - Before beginning any work on the SeaEra, be sure that all
power to the unit has been turned off.
WARNING: HAZARD OF FLOODING - Make sure seacocks are in the CLOSED or OFF position before
working on toilet.
NOTE:
The following information reflects the most probable causes and solutions to problems although not
every possible cause and solution is provided.
Any questions regarding servicing or operation of the SeaEra should be directed to our Technical Support Department in
Millville, NJ or Ft. Lauderdale, FL. Please have model and serial number available before calling.
PROBLEM
POSSIBLE CAUSE
SOLUTION
1. Poor pumpout, especially
solids.
1A. Clogged discharge line.
1A. Be sure discharge seacock is open. Clear line, remove
clog.
1B. Plumbing restrictions, bends and ells.
1C. Clogged vents.
1D. Mineral buildup in hoses and fittings.
1E. Low voltage.
1B. Replumb to eliminate bends and ells.
1C. Clean holding tank vent and vented loop vents
1D. Clean or replace affected parts. Replace hose if needed.
1E. Check voltage at toilet while toilet is running. If
less than nominal voltage of toilet (12, 24, or 32),
check condition of batteries and wire sizes. Check
terminals and wire connections for corrosion (heat at
terminals and junctions indicates a bad or corroded
connection).
2. Poor water flow, especially
at front of bowl (or no wa-
ter flow).
2A. Toilet not level.
2B. Restriction in intake line.
2C. Pump sucking air.
2A. Raise rear of toilet; check with level.
2B. Be sure seacock is open. Clear line-remove clog.
2C. Check all connections from intake thru-hull to intake
pump to be sure no air leaks are present.
2D. See 1E, above.
2D. Low voltage.
2E. Clogged strainer.
3A. “Marine life” lodged in rim of bowl.
2E. Remove or Clear debris from strainer.
3A. Remove and flush bowl with pressure hose to remove
all material. Install strainer in intake line to avoid re-
currence.
3. Foul odors from toilet area.
4. Bowl fills while underway.
3B. Permeated discharge hose.
3C. Sewage remaining in discharge line.
3B. Replace hose with Raritan sanitation hose (#SH).
3C. Flush toilet longer; replace hose if permeated; reroute
hose making a shorter run if possible.
4A. Close intake, then discharge seacock to determine
which is causing problem. If discharge, be sure the
vent or vented loop is clean. If intake, there is too
much pressure on seacock; contact Raritan Technical
Support.
4A. Pressure buildup at seacocks.
5. Water leaking from under
unit.
5A. Leaking bowl gasket.
5B. Leak at shaft seal.
5A. Tighten (4) bowl mounting nuts (#1226B).
5B. Check seal and motor shaft.
5C. Leak from seal plate area.
6A. Worn motor brushes.
6B. Motor bearings damaged by seal leak.
6C. Low or inconsistent voltage.
5C. Check seal plate o-ring.
6. Erratic operation/sluggish
running.
6A. Return motor to factory for servicing or replacement.
6B. Return motor to factory for servicing or replacement.
6C. See 1E above.
Tip for Removing Intake Pump
Set screw must be loosened
with 1/8" hex key before
removing the intake pump
from motor
Plug
13
Download from Www.Somanuals.com. All Manuals Search And Download.
SeaEra PARTS LIST
Part No. Description
Part No.
Description
1108A
1222AW
1226
1226B
1234
1236AW
1236E
1237
Macerator Nut
162100W Upper Housing Assembly
162200W Middle Housing Assembly
162300W Lower Housing Assembly
90° Discharge Fitting
Mounting Screw (4)
1/4-20 Hex Nut (4)
Bowl Gasket
Bowl Spud Assembly
Bowl Elbow
Marine-size Bowl
Household-style Bowl
Motor
Base
Seal Plate O-Ring
Seal Plate
Impeller
Impeller/Macerator Housing
Macerator Blade
163000
164000
31-102
41-260
C254
Inline Strainer
Push Button Switch
Shaft Seal
Bowl Elbow (Freshwater Models Only)
Joker Valve
CH38
F005
1/4-20 Threaded Stud (4)
Set Screw
1244
1610*
F020
Piston Fastener (4)
161105
161107
161110
161115
161120
161123
161125
161130
162135
162225
162305
162310
162315
162320
162325A
F144
F162VT
F164
HW1
M23A
Mounting Bolt Washer (4)
Mounting Bolt
Discharge Mounting Flange Fastener(4)
Mounting Screw Lockwasher (4)
Macerator Lockwasher (5)
Additional Parts Included with
INTEGRAL MODELS
Discharge Mounting Flange
Discharge Fitting
Cone Seal
161140
Motor Cover Integral
Additional Parts Included with
REMOTE MODELS
O-Ring
Lower Housing includes #162315
Diaphragm includes #162315
Piston (4)
Piston Seat (4) includes #162315
Bearing Plate Assembly includes
#162315
3/4" Hose Barb - 90° Fitting
3/4" Hose Barb - Straight Fitting (2)
Plug Fitting
161135
1660*
Motor Cover
Intake Motor
166000
166100
166200
Remote Intake Pump, 12V DC
Remote Intake Pump, 24V DC
Remote Intake Pump, 32V DC
Additional Parts Included with
FRESHWATER MODELS
162405
162410
162415
162420
162425
161135
Motor Cover
PLAVB0-5 Atmospheric Vacuum Breaker
Fitting Clip (3)
Fitting O-Ring (4)
PLA5
PLA6
PLA7
1/2” MPT PVC Nipple
1/2” FPT to 3/4” Barbed Elbow
1/2” GC Solenoid Valve
CWPS*A 1/2” GC Solenoid Valve
CWPSMB Water Solenoid Valve Mounting Bracket
Repair Kits
DIAPUMPRK Diaphragm Pump Repair Kit
SEADISRK
SeaEra Discharge Repair Kit
* Specify DC Voltage (12, 24, 32)
14
Download from Www.Somanuals.com. All Manuals Search And Download.
SeaEra Exploded Parts View
190601 - Recommended for use with
Freshwater Solenoid (Not Included)
15
Download from Www.Somanuals.com. All Manuals Search And Download.
LIMITED WARRANTY
Raritan Engineering Company warrants to the original purchaser that this product is free of defects
in materials or workmanship for a period of one year from the product’s date of purchase. Should
this product prove defective by reason of improper workmanship and/or materials within the
warranty period, Raritan shall, at its sole option, repair or replace the product.
1. TO OBTAIN WARRANTY SERVICE, Consumer must deliver the product prepaid, together with
a detailed description of the problem, to Raritan at 530 Orange St., Millville, N.J. 08332, or 3101 SW
2nd Ave. Ft. Lauderdale, FL 33315. When requesting warranty service, purchaser must present a
sales slip or other document which establishes proof of purchase. THE RETURN OF THE OWNER
REGISTRATIONCARDISNOTACONDITIONPRECEDENTOFWARRANTYCOVERAGE.
However, please complete and return the owner Registration Card so that Raritan can contact you
should a question of safety arise which could affect you.
2. THIS WARRANTY DOES NOT COVER defects caused by modifications, alterations, repairs or
service of this product by anyone other than Raritan; defects in materials or workmanship supplied
by others in the process of installation of this product; defects caused by installation of this product
other than in accordance with the manufacturer’s recommended installation instructions or standard
industry procedures; physical abuse to, or misuse of, this product. This warranty also does not cover
damages to equipment caused by fire, flood, external water, excessive corrosion or Act of God.
3. ANYEXPRESSWARRANTYNOTPROVIDEDHEREIN,ANDANYREMEDYFORBREACH
OF CONTRACT WHICH BUT FOR THIS PROVISION MIGHT ARISE BY IMPLICATION OR
OPERATION OF LAW, IS HEREBY EXCLUDED AND DISCLAIMED. ALL IMPLIED
WARRANTIES SUCH AS THOSE OF MERCHANTABILITY AND OF FITNESS FOR A
PARTICULAR PURPOSE, IF APPLICABLE, AS WELL AS ANY IMPLIED WARRANTIES
WHICH MIGHT ARISE BY IMPLICATION OF LAW, ARE EXPRESSLY LIMITED TO A
TERM OF ONE YEAR. SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG A
LIMITED WARRANTY LASTS, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU.
4. UNDER NO CIRCUMSTANCES SHALL RARITAN BE LIABLE TO PURCHASER OR ANY
OTHER PERSONS FOR ANY SPECIAL OR CONSEQUENTIAL DAMAGES, WHETHER
ARISING OUT OF BREACH OF WARRANTY, BREACH OF CONTRACT, OR OTHERWISE.
SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR
CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT
APPLY TO YOU.
5. No other person or entity is authorized to make any express warranty, promise or affirmation of fact
or to assume any other liability on behalf of Raritan in connection with its products except as
specifically set forth in this warranty.
6. This warranty gives you specific legal rights, and you may also have other rights which vary from
state to state.
530 Orange Street, P.O. Box 1157, Millville, NJ 08332 USA
Telephone: 856-825-4900 FAX: 856-825-4409
Southern Office and Plant:
3101 SW Second Avenue, Fort Lauderdale, FL 33315 USA
Telephone: 954-525-0378 FAX: 954-764-4370
L318 0103kgs
Specifications Subject to Change Without Notice
Printed in U.S.A.
16