Raritan Engineering Indoor Furnishings SeaEra Toilets User Guide

SeaEra Toilet  
OPERATION, MAINTENANCE AND INSTALLATION INSTRUCTIONS  
THE FOLLOWING ARE CAUTIONARY STATEMENTS THAT MUST BE READ AND  
FOLLOWED DURING BOTH INSTALLATION AND OPERATION.  
WARNING: Raritan Engineering Company, Inc. recommends that a qualified person or electrician install this  
product. Equipment damage, injury to personnel or death could result from improper installation.  
Raritan Engineering Company, Inc. accepts no responsibility or liability for damage to equipment,  
injuryordeathtopersonnelthatmayresultfromimproperinstallationoroperationofthisproduct.  
WARNING: HAZARD OF SHOCK OR FIRE  
Always use recommended fuse, circuit breaker and wire size.  
Motors used with this product are “Ignition Protected”. They are not however, explosion-  
proof as defined in 46CFR 110.15-65(e), Subchapter J-Electrical Engineering.  
DO NOT run continuously for more than 30 seconds.  
WARNING: HAZARD OF FLOODING - Always shut off seacock(s) before leaving the boat unattended.  
Double clamp all below waterline hose fittings and check frequently for integrity.  
Pressurized  
Freshwater Model  
Sea Water Model  
(Remote Pump)  
Sea Water Model  
(Integral Pump)  
The SeaEra toilet is a powerful centrifugal macerating toilet that thoroughly breaks down waste.  
1-800-352-5630  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Cleaning Instructions  
IMPORTANT: Do not use cleaners that contain  
ammonia, ethyl acetate, phosphoric acid or  
concentrated chlorine bleach. These may cause  
damage to the toilet.  
Using C.P. a bio-enzymatic toilet bowl cleaner  
(available from Raritan Engineering) will keep the  
bowl clean and fresh smelling.  
Recommend Visual Inspection  
For leaks at toilet and hose connections  
Hose clamps  
Condition of hoses  
Seacocks  
Condition of wires and connections  
In-Line Strainer (if you have one)  
Cleaning In-Line Strainer  
(Sea Water Models only)  
Clean Gasket  
and Gasket  
Contact Surfaces  
Thoroughly  
1. Shut off intake seacock.  
2. Unscrew bowl.  
Filter  
3. Remove filter.  
4. Clean bowl and filter with a clean cloth.  
5. Clean gasket and gasket contact surfaces  
thoroughly.  
Bowl  
Unscrew  
Tighten  
6. Replace gasket, filter and bowl.  
7. Open seacock.  
8. Check for leaks.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
IMPORTANT  
Improper winter lay up is a major cause of  
marine toilet failure.  
Use only nontoxic antifreeze.  
Flush toilet several times to clear waste  
from system.  
Dispose of all antifreeze in accordance with  
local and federal regulations.  
Winterize holding tanks, plumbing,  
treatment systems (MSD’s), etc.  
independently following manufacturer’s  
instructions.  
Pressurized Freshwater Models  
Pressurized Freshwater Model  
Parts Required  
1" (25mm) or 1 1/2" (38mm) I.D.discharge  
hose, approximately 3 feet (1m) long  
Nontoxic  
Antifreeze  
Two buckets  
Nontoxic antifreeze approximately 1 quart  
(1 liter)  
Steps  
1. Close discharge seacock.  
2. Shut off intake water at source.  
3. Turn off power to unit.  
4. Disconnect and drain discharge hose.  
5. Disconnect intake hoses from vacuum breaker  
and place in one of the buckets.  
6. Connect hose to toilet’s discharge and place  
in other bucket.  
7. Pour antifreeze in bowl.  
8. Turn on power to unit and flush until antifreeze  
is removed from the bowl and water is drained  
from the solenoid and hose.  
9. Disconnect power to toilet.  
10. Reconnect intake hoses to vacuum breaker.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Integral and Remote Intake Pump Models  
Parts Required  
3/4" (19mm) I.D. intake hose approximately 3 feet  
(1m) long.  
Sea Water Model (Integral Pump)  
Nontoxic  
Antifreeze  
1" (25mm) or 1 1/2" (38mm) I.D. discharge hose  
approximately 3 feet (1m) long.  
Two buckets  
Nontoxic antifreeze approximately 1 quart (1 liter)  
Steps  
1. Close the intake and discharge seacocks.  
2. Turn off power to unit.  
3. Disconnect and drain intake hose, discharge hose  
and In-Line Strainer.  
4. Connect short hoses to toilet’s intake and  
discharge.  
5. Place one bucket under hose connected to toilet’s  
discharge.  
Sea Water Model (Remote Pump)  
Nontoxic  
Antifreeze  
6. Pour nontoxic antifreeze in other bucket.  
7. Place hose connected to intake pump into bucket  
with antifreeze.  
8. Turn on power to unit and flush toilet until  
antifreeze begins to be discharged from toilet.  
9. Disconnect power to toilet.  
RECOMMISSIONING  
1. Using the buckets, hoses and approximately one  
gallon (3.8 liters) of clean fresh water, flush  
antifreeze out of the toilet (see Winterizing).  
Dispose of antifreeze in accordance with local  
and federal regulations.  
2. Reconnect the intake and discharge hoses and  
open both seacocks and water source valve.  
3. Check all connections for leaks with several test  
flushes.  
SYSTEM START-UP  
1. Open seacock(s).  
NOTE: Pressurized freshwater models; open water  
source valve.  
2. Turn on power to toilet.  
3. Flush toilet per Operation Instructions.  
4. Check for leaks.  
IMPORTANT: If toilet does not flush properly  
or if water does not enter the bowl within 10  
seconds, refer to Troubleshooting.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Pressurized Freshwater or Remote SeaWater Model  
Integral SeaWater Model  
14 3/8" (36.5cm) Household  
19 3/4" (52.1cm) Household  
17 1/2" (44.5cm) Marine  
19 3/4"(50.2cm) Household  
16 3/4"(42.6cm) Marine  
13" (33cm) Marine  
14 7/8"  
(37.8cm)  
Household  
14 1/2"  
(36.8cm)  
Marine  
13 3/8" (34cm)  
6 5/8" (16.8cm)  
11 1/8" (28.3cm)  
Plumbing  
Maximum suction of Intake pump  
4 Ft. (1.2m) from Intake Pump.  
(Maximum height above waterline)  
CONVERSIONS  
Wire - AWG to mm2  
Maximum height of discharge vented loop 6 Ft. (1.8m) from base of toilet.  
AWG 16  
14  
12  
10  
8
6
4
2
minimum flow rate of 3 gpm (11.3 liters).  
Pressurized water source requirements  
minimum pressure of 5 psi (34.5 kPa).  
mm2  
1.5  
2.5  
4.0  
6.0  
10.0 16.0 25.0 35.0  
NOTES: for Wiring  
1.  
Distances are from source to unit and back to source.  
Feet to Meters  
Distance from power source to remote intake pump MUST be included when  
determining total distance.Same wire size MUST be used for lower base and  
remote intake pump.  
Feet  
10  
15  
20  
25  
30  
40  
50  
2.  
Meter 3.1  
4.6  
6.1  
7.6  
9.2  
12.2 15.2  
3.  
4.  
5.  
Recommended conductor wire minimum AWG (mm2) for 3% voltage drop.  
Recommended conductor sizes are based on 105oC rated insulation.  
Refer to ABYC Standards for other insulation ratings.  
For 120/240 VAC units use 24VDC specifications from transformer to unit.  
Sea Water Model - Recommended Wire and Fuse/Circuit Breaker Size  
Integral Pump  
and lower base  
Remote Pump  
and lower base  
Remote Pump  
only  
Circuit  
Units  
Voltage  
15  
feet  
20  
feet  
30  
feet  
40  
feet  
50  
feet  
Breaker/fuse  
size (amps)  
Amp. draw  
@ nominal  
voltage  
Amp. draw  
@ nominal  
voltage  
Amp. draw  
@ nominal  
voltage  
12 VDC  
24 VDC  
32 VDC  
25  
15  
15  
18  
10  
23  
12.5  
9
10  
5
10 AWG 8 AWG  
6 AWG  
6 AWG  
4 AWG  
14 AWG 14 AWG 12 AWG 10 AWG 10 AWG  
14 AWG 14 AWG 14 AWG 12 AWG 12 AWG  
7.5  
4
Pressurized Freshwater Model - Recommended Wire and Fuse/Circuit Breaker Size  
Circuit  
Breaker/fuse  
size (amps)  
Amp. draw  
@ nominal  
voltage  
10 feet  
15 feet  
20 feet  
30 feet  
40 feet  
50 feet  
Units  
Voltage  
12 VDC  
Lower Base  
12 AWG 10 AWG 10 AWG 8 AWG  
6 AWG  
6 AWG  
6 AWG  
25  
15  
15  
13  
7.5  
5
24 VDC  
Lower Base  
14 AWG 12 AWG 10 AWG 10 AWG 8 AWG  
32 VDC  
Lower Base  
16 AWG 16 AWG 14 AWG 12 AWG 10 AWG 10 AWG  
12, 24, and 32 VDC  
Water Solenoid  
Valve  
16 AWG 16 AWG 16 AWG 16 AWG 16 AWG 16 AWG  
3
2
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Parts Included  
Additional Parts Required  
Four stainless steel mounting bolts or lag  
screws (minimum 1/4" [6mm]) and washers  
1" (25mm) or 1 1/2" (38mm) I.D. discharge hose  
3/4" (19mm) I.D. reinforced intake hose  
3/4" (19mm) and 1" (25mm) or 1 1/2" (38mm)  
hose clamps (two for each connection below  
waterline)  
Wire  
Terminals  
Fuse/circuit breaker  
All Complete Toilets  
Toilet Bowl  
Seat and Cover  
Lower Base Assembly  
Motor Cover  
Push Button Switch  
Sea Water Model  
3/4" Hose Barb - straight fitting (2)  
3/4" Hose Barb - 90° fitting  
Plug Fitting  
In-Line Strainer with fittings  
3/4" Stainless Steel Hose Clamps (2)  
Pressurized Freshwater Models  
Atmospheric Vacuum Breaker (PLAVB0-5)  
Solenoid Valve with fittings  
Solenoid Valve Mounting Bracket  
Tools Required  
5/16" nut driver  
Wrench or screw driver  
5/8" (16mm) drill bit  
Bit for drilling mounting surface  
Wire cutters  
Wire terminal crimpers  
Hose cutters  
Tape measure  
Mounting Toilet  
Mounting surface must be flat and solid.  
1. Install seat on toilet.  
2. Remove motor cover.  
3. Place toilet where it will be located.  
Make sure there is room to route hoses.  
Make sure seat will open properly.  
4. Mark location of toilet base mounting holes  
on mounting surface.  
5. Drill holes for toilet mounting bolts/screws.  
NOTE: Hole size will depend on type of bolt/  
screws used (5/16" [8mm] size bolts/screws are  
recommended).  
6. Secure toilet to surface.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
90° Rotation of Toilet Bowl  
Toilet bowl can be rotated 90° on the base, for  
installing in confined locations.  
NOTE: SeaEra Models with Integral Pump:  
Replace existing hose from the intake pump to the  
toilet bowl with a longer hose.  
1. Determine which direction bowl is to be  
mounted.  
2. Remove hose at back of toilet (Sea Water  
Model with Integral Pumps ONLY).  
3. Remove four vinyl caps at the base of toilet  
bowl.  
4. Remove four nuts and shoulder washers.  
5. Carefully remove toilet bowl from base.  
6. Rotate toilet bowl to desired position.  
7. Replace four shoulder washers, nuts and vinyl  
caps.  
NOTE: Tighten nuts carefully and evenly. Do  
Not over tighten.  
Mounting Push Button Switch  
Mount Push Button Switch in an accessible  
location.  
Make certain wires can be routed to Push  
Button Switch.  
Wire terminals must have clearance when  
installed.  
1/4" Minimum clearance from terminals to any object  
1. Drill 5/8" (16mm) hole.  
2. Attach wires to Push Button Switch terminals  
(see wiring section).  
3. Install Push Button Switch through back of  
mounting surface.  
4. Install waterproof nut on Push Button Switch.  
5. Secure in place with inner nut.  
Inner Nut  
Install the Warning Label (L322) where it can  
be easily seen.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Mounting Water Solenoid Valve  
(Pressurized Freshwater Models Only)  
1. Locate valve on a solid flat surface in an area  
that is dry and well ventilated.  
2. Mark and drill holes for water solenoid mounting  
bracket.  
NOTE: Hole size will depend on type of bolts/screws  
used (1/4" [6mm] size bolt/screws are recommended).  
3. Mount bracket.  
4. Install fittings provided (PLA7) on valve’s inlet  
and outlet ports.  
From  
Pressurized  
Freshwater  
Source  
5. Attach valve to bracket. hoses must be installed  
according to flow markings on valve body.  
PLA7  
To inlet port of  
IN  
OUT  
vacuum breaker  
Mounting Atmospheric Vacuum Breaker  
(Pressurized Freshwater Model only)  
Min. 6”  
(15.3 cm)  
1. Install fittings as shown.  
2. Locate mounting area that is a minimum of 6"  
(15.3cm) above toilet.  
3. Secure where top is in horizontal position.  
Mounting In-Line Strainer  
(Seawater Models Only)  
Make sure strainer bowl is tight.  
1. Locate strainer where it will be accessible.  
2. Mark and drill mounting holes.  
NOTE: Hole size will depend on type of bolts/screws  
used (1/4" [6mm] size bolts/screws are  
recommended).  
3. Install fittings provided (PLA7) on strainer’s inlet  
and outlet ports.  
Flow Marking  
NOTE: Use thread sealant.  
4. Mount strainer. Hoses must be installed according  
to flow marking on strainer top.  
Mounting Remote Intake Pump  
(Remote Pump Models Only)  
1. Remote intake pump must be mounted on a  
flat solid surface in an area that is dry and well  
ventilated.  
2. Mark and drill mounting holes.  
NOTE: Hole size will depend on type of bolts/screws  
used. (1/4" [6mm] size bolts/screws are  
recommended).  
3. Mount pump. Do not over tighten bolts.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Pressurized Freshwater Model  
Installed AboveWaterline  
PLUMBING  
WARNING: Hazard of Flooding  
Toilets mounted at or below the waterline  
must have a vented loop installed in the  
discharge line. The top of the vented loop  
must be a minimum of 4" (10cm) above  
the waterline at the boats greatest angle  
of heel (see vented loop manufacturer’s  
instructions).  
Wa
Waterline  
line  
Sea Water Models must also have a vented  
loop installed between the intake pump  
and the toilet bowl.  
SeaWater Model with Integral Pump  
Installed BelowWaterline  
Double clamp all below waterline  
connections.  
IMPORTANT  
Discharge  
Vented  
Loop  
Intake Vented  
Loop  
Fittings and 90° bends should be kept  
to a minimum.  
SeaEra  
Toilet  
In-Line Strainer must be installed on  
Sea Water Models per Installation  
Instructions. Failure to do so may void  
Warranty.  
Waterline  
Lectra/San  
In-Line  
Strainer  
Discharge  
Seacock  
Intake  
Seacock  
Discharging untreated sewage is  
forbidden in all U. S. waters within the  
three-mile limit.  
Thru-hull fittings and seacocks must  
be installed where they are easily  
accessible.  
Remote Intake Pump Model  
Mounted AboveWaterline  
Discharge  
Vented  
Loop  
Use only quality reinforced hoses.  
Secure all hoses properly.  
ne  
Discharge Lines  
1. Connect quality sanitation hose 1"  
(25mm) or 1 1/2" (38mm) I.D. to  
discharge fitting on toilet.  
2. Run hose to appropriate device (i.e.:  
treatment system, holding tank, etc.).  
1" (25mm)  
Discharge Fitting  
Hose  
1 1/2" (38mm)  
Discharge Fitting  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Intake Lines  
Pressurized Freshwater Models  
From Pressurized  
Freshwater Source  
(Shut Off Valve)  
Install a shut off valve in intake line before water  
solenoid valve.  
1. Connect hose from shut off valve to inlet port  
of water solenoid valve.  
IN  
NOTE: To avoid malfunction of water solenoid due  
to debris in water, installation of Freshwater  
Strainer (190601) is recommended.  
2. Connect hose from outlet port of water solenoid  
valve to inlet port of vacuum breaker.  
OUT  
To Inlet Port  
of Vacuum  
Breaker  
3. Connect hose from outlet port of vacuum breaker  
to bowl elbow.  
Outlet Port  
Inlet Port  
NOTE: Vacuum breaker must be last mechanical  
component before bowl elbow.  
Outlet Port  
Arrow  
Sea Water Models  
Intake pump fittings are interchangeable to allow  
more flexibility during installation. Inlet ports are  
located on either side of intake pump. Outlet port  
(to toilet bowl) is at top of intake pump.  
1. Slide fitting clips to open position.  
2. Select inlet port to be used.  
Inlet Ports  
3. Install appropriate fittings into inlet and outlet  
ports.  
NOTE: The 90° fitting can be rotated 360°.  
4. Install the plug fitting into unused inlet port.  
Closed  
Open  
IMPORTANT: Be sure not to install plug fitting  
into outlet port! Damage will occur!  
To Bowl  
5. Slide fitting clips back to closed position.  
6. Connect hose from seacock to inlet port of  
In-Line Strainer. Use hose clamp provided.  
7. Connect hose from outlet port of In-Line  
Strainer to inlet port of intake pump. Use hose  
clamp provided.  
Plug  
From Strainer  
IMPORTANT: Double clamp all below  
waterline hose connections!  
From  
Seacock  
8. Remote Pump Models Only: Connect hose  
from outlet port of intake pump to bowl elbow  
located on back of toilet bowl. (Integral pump  
model is already connected).  
To Intake  
Pump  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WIRING  
Pressurized FreshwaterWiring  
WARNING: Hazard of Shock and Fire  
Always use proper wire, wire connectors  
and fuse/circuit breaker. See Specification  
Chart.  
on  
Secure wire properly.  
3 Amp  
Fuse  
Do not connect appliances to toilet circuit.  
Make sure power is off before proceeding.  
Use proper wire terminals for all wire  
connections.  
Solenoid  
Valve  
se or  
rcuit  
1. Determine proper wire size by measuring  
distance from:  
aker  
Power Source to push-button to toilet  
motor and back to power source.  
Remote pump units - also include distance  
from power source for remote pump to  
remote pump and back. Same wire must  
be used for both lower base and remote  
pump.  
Remote PumpWiring  
2. Select proper wire and fuse/circuit breaker size  
from Specifications on Installation page.  
Push Button  
Switch  
Black  
NEG (-)  
3. Install fuse/circuit breaker in positive line at  
source.  
4. Connect positive wire from fuse/circuit  
breaker to Push Button Switch.  
Fuse or  
Circuit  
Breaker  
Orange  
POS (+)  
Black  
NEG (-)  
NEG POS  
5. Connect wire from Push Button Switch to  
orange wire on motor(s).  
NOTE: Pressurized Freshwater Models; connect  
wire from Push Button Switch to orange wire on  
motor and from Push Button Switch to one of the  
wires on water solenoid valve. The water solenoid  
valve is not polarity sensitive.  
Integral PumpWiring  
6. Connect wire from battery negative or power  
source ground buss to black wire (negative)  
on motor(s).  
Push Button  
Switch  
Fuse or  
Circuit  
Breaker  
NOTE: Pressurized Freshwater Models; connect  
remaining wire from water solenoid valve to  
battery negative or power source ground buss.  
Orange  
POS (+)  
NEG POS  
Black  
NEG (-)  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TROUBLESHOOTING  
WARNING: HAZARD OF ELECTRIC SHOCK - Before beginning any work on the SeaEra, be sure that all  
power to the unit has been turned off.  
WARNING: HAZARD OF FLOODING - Make sure seacocks are in the CLOSED or OFF position before  
working on toilet.  
NOTE:  
The following information reflects the most probable causes and solutions to problems although not  
every possible cause and solution is provided.  
Any questions regarding servicing or operation of the SeaEra should be directed to our Technical Support Department in  
Millville, NJ or Ft. Lauderdale, FL. Please have model and serial number available before calling.  
PROBLEM  
POSSIBLE CAUSE  
SOLUTION  
1. Poor pumpout, especially  
solids.  
1A. Clogged discharge line.  
1A. Be sure discharge seacock is open. Clear line, remove  
clog.  
1B. Plumbing restrictions, bends and ells.  
1C. Clogged vents.  
1D. Mineral buildup in hoses and fittings.  
1E. Low voltage.  
1B. Replumb to eliminate bends and ells.  
1C. Clean holding tank vent and vented loop vents  
1D. Clean or replace affected parts. Replace hose if needed.  
1E. Check voltage at toilet while toilet is running. If  
less than nominal voltage of toilet (12, 24, or 32),  
check condition of batteries and wire sizes. Check  
terminals and wire connections for corrosion (heat at  
terminals and junctions indicates a bad or corroded  
connection).  
2. Poor water flow, especially  
at front of bowl (or no wa-  
ter flow).  
2A. Toilet not level.  
2B. Restriction in intake line.  
2C. Pump sucking air.  
2A. Raise rear of toilet; check with level.  
2B. Be sure seacock is open. Clear line-remove clog.  
2C. Check all connections from intake thru-hull to intake  
pump to be sure no air leaks are present.  
2D. See 1E, above.  
2D. Low voltage.  
2E. Clogged strainer.  
3A. “Marine life” lodged in rim of bowl.  
2E. Remove or Clear debris from strainer.  
3A. Remove and flush bowl with pressure hose to remove  
all material. Install strainer in intake line to avoid re-  
currence.  
3. Foul odors from toilet area.  
4. Bowl fills while underway.  
3B. Permeated discharge hose.  
3C. Sewage remaining in discharge line.  
3B. Replace hose with Raritan sanitation hose (#SH).  
3C. Flush toilet longer; replace hose if permeated; reroute  
hose making a shorter run if possible.  
4A. Close intake, then discharge seacock to determine  
which is causing problem. If discharge, be sure the  
vent or vented loop is clean. If intake, there is too  
much pressure on seacock; contact Raritan Technical  
Support.  
4A. Pressure buildup at seacocks.  
5. Water leaking from under  
unit.  
5A. Leaking bowl gasket.  
5B. Leak at shaft seal.  
5A. Tighten (4) bowl mounting nuts (#1226B).  
5B. Check seal and motor shaft.  
5C. Leak from seal plate area.  
6A. Worn motor brushes.  
6B. Motor bearings damaged by seal leak.  
6C. Low or inconsistent voltage.  
5C. Check seal plate o-ring.  
6. Erratic operation/sluggish  
running.  
6A. Return motor to factory for servicing or replacement.  
6B. Return motor to factory for servicing or replacement.  
6C. See 1E above.  
Tip for Removing Intake Pump  
Set screw must be loosened  
with 1/8" hex key before  
removing the intake pump  
from motor  
Plug  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SeaEra PARTS LIST  
Part No. Description  
Part No.  
Description  
1108A  
1222AW  
1226  
1226B  
1234  
1236AW  
1236E  
1237  
Macerator Nut  
162100W Upper Housing Assembly  
162200W Middle Housing Assembly  
162300W Lower Housing Assembly  
90° Discharge Fitting  
Mounting Screw (4)  
1/4-20 Hex Nut (4)  
Bowl Gasket  
Bowl Spud Assembly  
Bowl Elbow  
Marine-size Bowl  
Household-style Bowl  
Motor  
Base  
Seal Plate O-Ring  
Seal Plate  
Impeller  
Impeller/Macerator Housing  
Macerator Blade  
163000  
164000  
31-102  
41-260  
C254  
Inline Strainer  
Push Button Switch  
Shaft Seal  
Bowl Elbow (Freshwater Models Only)  
Joker Valve  
CH38  
F005  
1/4-20 Threaded Stud (4)  
Set Screw  
1244  
1610*  
F020  
Piston Fastener (4)  
161105  
161107  
161110  
161115  
161120  
161123  
161125  
161130  
162135  
162225  
162305  
162310  
162315  
162320  
162325A  
F144  
F162VT  
F164  
HW1  
M23A  
Mounting Bolt Washer (4)  
Mounting Bolt  
Discharge Mounting Flange Fastener(4)  
Mounting Screw Lockwasher (4)  
Macerator Lockwasher (5)  
Additional Parts Included with  
INTEGRAL MODELS  
Discharge Mounting Flange  
Discharge Fitting  
Cone Seal  
161140  
Motor Cover Integral  
Additional Parts Included with  
REMOTE MODELS  
O-Ring  
Lower Housing includes #162315  
Diaphragm includes #162315  
Piston (4)  
Piston Seat (4) includes #162315  
Bearing Plate Assembly includes  
#162315  
3/4" Hose Barb - 90° Fitting  
3/4" Hose Barb - Straight Fitting (2)  
Plug Fitting  
161135  
1660*  
Motor Cover  
Intake Motor  
166000  
166100  
166200  
Remote Intake Pump, 12V DC  
Remote Intake Pump, 24V DC  
Remote Intake Pump, 32V DC  
Additional Parts Included with  
FRESHWATER MODELS  
162405  
162410  
162415  
162420  
162425  
161135  
Motor Cover  
PLAVB0-5 Atmospheric Vacuum Breaker  
Fitting Clip (3)  
Fitting O-Ring (4)  
PLA5  
PLA6  
PLA7  
1/2” MPT PVC Nipple  
1/2” FPT to 3/4” Barbed Elbow  
1/2” GC Solenoid Valve  
CWPS*A 1/2” GC Solenoid Valve  
CWPSMB Water Solenoid Valve Mounting Bracket  
Repair Kits  
DIAPUMPRK Diaphragm Pump Repair Kit  
SEADISRK  
SeaEra Discharge Repair Kit  
* Specify DC Voltage (12, 24, 32)  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SeaEra Exploded Parts View  
190601 - Recommended for use with  
Freshwater Solenoid (Not Included)  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
LIMITED WARRANTY  
Raritan Engineering Company warrants to the original purchaser that this product is free of defects  
in materials or workmanship for a period of one year from the product’s date of purchase. Should  
this product prove defective by reason of improper workmanship and/or materials within the  
warranty period, Raritan shall, at its sole option, repair or replace the product.  
1. TO OBTAIN WARRANTY SERVICE, Consumer must deliver the product prepaid, together with  
a detailed description of the problem, to Raritan at 530 Orange St., Millville, N.J. 08332, or 3101 SW  
2nd Ave. Ft. Lauderdale, FL 33315. When requesting warranty service, purchaser must present a  
sales slip or other document which establishes proof of purchase. THE RETURN OF THE OWNER  
REGISTRATIONCARDISNOTACONDITIONPRECEDENTOFWARRANTYCOVERAGE.  
However, please complete and return the owner Registration Card so that Raritan can contact you  
should a question of safety arise which could affect you.  
2. THIS WARRANTY DOES NOT COVER defects caused by modifications, alterations, repairs or  
service of this product by anyone other than Raritan; defects in materials or workmanship supplied  
by others in the process of installation of this product; defects caused by installation of this product  
other than in accordance with the manufacturer’s recommended installation instructions or standard  
industry procedures; physical abuse to, or misuse of, this product. This warranty also does not cover  
damages to equipment caused by fire, flood, external water, excessive corrosion or Act of God.  
3. ANYEXPRESSWARRANTYNOTPROVIDEDHEREIN,ANDANYREMEDYFORBREACH  
OF CONTRACT WHICH BUT FOR THIS PROVISION MIGHT ARISE BY IMPLICATION OR  
OPERATION OF LAW, IS HEREBY EXCLUDED AND DISCLAIMED. ALL IMPLIED  
WARRANTIES SUCH AS THOSE OF MERCHANTABILITY AND OF FITNESS FOR A  
PARTICULAR PURPOSE, IF APPLICABLE, AS WELL AS ANY IMPLIED WARRANTIES  
WHICH MIGHT ARISE BY IMPLICATION OF LAW, ARE EXPRESSLY LIMITED TO A  
TERM OF ONE YEAR. SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG A  
LIMITED WARRANTY LASTS, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU.  
4. UNDER NO CIRCUMSTANCES SHALL RARITAN BE LIABLE TO PURCHASER OR ANY  
OTHER PERSONS FOR ANY SPECIAL OR CONSEQUENTIAL DAMAGES, WHETHER  
ARISING OUT OF BREACH OF WARRANTY, BREACH OF CONTRACT, OR OTHERWISE.  
SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR  
CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT  
APPLY TO YOU.  
5. No other person or entity is authorized to make any express warranty, promise or affirmation of fact  
or to assume any other liability on behalf of Raritan in connection with its products except as  
specifically set forth in this warranty.  
6. This warranty gives you specific legal rights, and you may also have other rights which vary from  
state to state.  
530 Orange Street, P.O. Box 1157, Millville, NJ 08332 USA  
Telephone: 856-825-4900 FAX: 856-825-4409  
Southern Office and Plant:  
3101 SW Second Avenue, Fort Lauderdale, FL 33315 USA  
Telephone: 954-525-0378 FAX: 954-764-4370  
L318 0103kgs  
Specifications Subject to Change Without Notice  
Printed in U.S.A.  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Q Logic Switch MKII BASE16 User Guide
Radio Shack Radio 12 208 User Guide
Rival Slow Cooker SCE600BWCTCN User Guide
RSA Lighting Indoor Furnishings BX40 User Guide
Russound Stereo Amplifier CA44pi User Guide
Samsung Headphones GH68 15048A User Guide
Samsung Tablet Tab4 User Guide
Samsung Weather Radio TRC 445 User Guide
Sanyo DVD Recorder DVR S120 User Guide
Sears Blower 257796362 User Guide