| PPA450   4500 Watt   Limited Warranty   P P P P P P A A A 2 3 4 0 0 5 0 0 0 A A A m m m p p p l l l i i i f f f i i i e e e r r r All PYLE PRO products are carefully constructed and tested before   shipment. Units purchased in the USA are warranted to be free of   defects in material and workmanship for two (2) years from the date   of purchase. This warranty is limited to the original retail purchaser   of the amplifier.   Should the unit fail due to factory defects in material or workmanship,   your unit will be repaired or replaced at the sole discretion of PYLE.   To obtain warranty service, you must first call our Consumer Return   Hotline at (718) 236-6948 to obtain a Return Authorization Number.   This R.A. # must appear on the outside of your package and on all   paperwork relating to your return.   When returning the unit to us for warranty service, it must be carefully   packed and shipped, prepaid, to:   R.A.#: _____________   PYLE PRO Service Center   1600 63rd Street   Brooklyn, NY 11204   You must also include the following items with your return:   • • A copy of your sales receipt or other proof of purchase   A brief letter, indicating the problem you are experiencing   with the product   • Include in your letter your return address, daytime phone   number and R.A. number   • Also include a check or money order for $15.00 for return   shipping, handling and insurance, or provide your Visa/MC   number with expiration date.   Our obligation under this warranty is limited to the repair or replacement   of the defective unit when it is returned to us prepaid. This warranty   will be considered void if the unit was tampered with, improperly   serviced or subject to misuse, neglect or accidental damage.   Owner’s Manual   Download from Www.Somanuals.com. All Manuals Search And Download.   Amplifier Specifications   PPA 200   PPA 300   PPA 450   Input Impedance, balanced (unbalanced)   20 k-Ohms (10 k-Ohms)   20 k-Ohms (10 k-Ohms)   20 k-Ohms (10 k-Ohms)   Connecting to standard AC power   MONO OPERATION   After making all other connections, set the POWER switch   to OFF position. Then connect the power cord to a standard   AC outlet.   Continuous Output Power   Stereo Mode   SWITCH IN “MONO” POSITION   20 Hz to 20 kHz,   8 Ohms   70W x 2   100W x 2   110W x 2   130W x 2   800W x 2   120W x 2   160W x 2   170W x 2   200W x 2   1200W x 2   170W x 2   220W x 2   230W x 2   260W x 2   1600W x 2   1 kHz, 4 Ohms   Mounting the amplifier   This amplifier is designed to accept standard rack mounting   installations. Two slots on each end of the front panel make   it suitable for such an installation.   Maximum Power,   Maximum Power,   8 4 Ohms   Ohms   Peak Power,   8 Ohms   CH 2   CH 1   Tightly secure four mounting screws (not supplied) through   these fours slots and into your standard electronics equipment   rack.   Bridged Mode   20 Hz to 20 kHz,   8 Ohms   200W x 1   200W x 1   2000W x 1   320W x 1   320W x 1   3000W x 1   440W x 1   440W x 1   4500W x 1   B A L A N C E D I N P U T S 1 kHz,   8 Ohms   VOLTAGE   P O W E R C O N S - U M N P T I O N : INPUTS   CH-1   OUTPUTS   BRIDGE   ~ 3 A 0 C V i 6 1 1 5 / 2 0 / 5 0 H z CH-2   CH-2   CH-1   Peak Power   MONO   CH   CH   - - 1 STEREO   BRIDGE   GROUND LIFT   GND   2 LIFT   Turning the amplifier on   1. Turn on the audio input source equipment which is   connected to the amplifier INPUT jacks.   F U S E THD at rated output power   Frequency Response +/–   0.1%   10 Hz to 50 kHz   1.0V   0.1%   10 Hz to 50 kHz   1.0V   0.1%   10 Hz to 50 kHz   1.0V   3 dB   MONO SIGNAL SOURCE   2. Set the amplifier’s Channel 1 and Channel 2 output level   gain controls to the minimum level settings.   USE   CHANNEL 1   INPUT ONLY   Input Sensitivity for rated output power   Signal-to-Noise Ratio A-Weighted   3. Push in the power switch to turn the amplifier on.   100 dB   100 dB   100 dB   CAUTION! Do not use   balanced and unbalanced   inputs simultaneously!!   Speaker Impedance   Stereo   Bridged   4-16 Ohms   8-16 Ohms   4-16 Ohms   8-16 Ohms   4-16 Ohms   8-16 Ohms   Using the power LED meters   Bridged Mode Operation   The meter pointer position indicates the amplifier output   power. For ease of reading in dark environments, the meter   is illuminated.   This amplifier can operate in a mono bridged output mode, if   your speakers can handle the following power output levels:   120VAC,60Hz/230VAC,50Hz   120VAC,60Hz/230VAC,50Hz   120VAC,60Hz/230VAC,50Hz   Power Requirement   PPA 200: 2000 watts   PPA 300: 3000 watts   PPA 450: 4500 watts   Dimensions   (mm)   H x W x D, inches   3 15/32 x 19 x 10 11/16   (88 x 482 x 271)   3 15/32 x 19 x 10 11/16   (88 x 482 x 271)   3 15/32 x 19 x 10 11/16   (88 x 482 x 271)   Using the Channel 1 and Channel 2 Output Level controls   Rotate output level gain clockwise to increase, or counter-   clockwise to decrease the output power. To get the best   performance with the least sound distortion, always adjust   the output level gain so the meter's pointer does not   continuously exceed the extreme right of the meter's scale.   Weight, lbs (kg)   16.7 Ibs (7.6)   18.5 Ibs (8.4)   20 Ibs (9.1)   As shown in the diagram below, connect the speaker's positive   (+) to the amplifier's red speakers left (1/2) terminals and   negative (-) to red speakers right (1/2) terminals.   The speaker right (+) on the amplifier is used as a negative (-)   terminal for a bridged connection.   CAUTION: It is possible to overdrive the amplifier by   setting output level gain too high, which may cause   damage or failure.   MONO BRIDGED OPERATION   SWITCH IN “BRIDGED” POSITION   About the internal protect circuitry   Special clip circuitry incorporated into your PYLE PPA   amplifier’s design protects the amplifier and speaker system   from being damaged from overdriving power.   DO NOT USE   BLACK TERMINALS   Under normal conditions, the amplifier’s clip indicator will   flicker as the output power momentarily exceeds the level   as set by the output level gain selector.   B A L A N C E D I N P U T S VOLTAGE   P O W E R C O N S - U M N P T I O N : INPUTS   CH-1   OUTPUTS   BRIDGE   ~ 3 A 0 C V i 6 1 1 5 / 2 0 / 5 0 H z CH-2   CH-2   CH-1   However, under excessive output conditions, the protect   indicator lights remain on continuously, alerting you that   the special clip circuitry has become active. When this   occurs, you should simply reduce the output power level   by rotating the Master Volume control counterclockwise.   MONO   CH   CH   - - 1 STEREO   BRIDGE   GROUND LIFT   GND   2 LIFT   F U S E MONO SIGNAL SOURCE   USE   CHANNEL 1   INPUT ONLY   CAUTION! Do not use   balanced and unbalanced   inputs simultaneously!!   3-PYLE PPA Amplifier Owner’s Manual   PYLE PPA Amplifier Owner’s Manual-4   Download from Www.Somanuals.com. All Manuals Search And Download.   |