Cat. No.
22-218
OWNER’S MANUAL
Please read before using this equipment.
8-Range Multitester
Download from Www.Somanuals.com. All Manuals Search And Download.
Cautions:
• Read this manual completely before you use the meter.
• If you are not familiar with meters and testing proce-
dures, we suggest that you read a book about the sub-
ject, such as “Using Your Meter” (Radio Shack Cat. No.
62-2039).
Note: You need one AA battery (not supplied) to power your
multitester.
Download from Www.Somanuals.com. All Manuals Search And Download.
3
A WORD ABOUT SAFETY
We have taken every precaution in designing this meter to en-
sure that it is as safe as possible. But safe operation depends
on you, the operator. We recommend that you follow these
simple safety rules:
• Never apply voltages to the meter that exceed the limits
given in the specifications. Never apply more than 1000V
DC or AC between any input terminals, or between an
input terminal and ground.
Download from Www.Somanuals.com. All Manuals Search And Download.
4
• Use extreme caution when you work with voltages above
40V. Always disconnect power from the circuit you are
measuring before you connect test probes to high-volt-
age points.
• Never connect the test probes to a source of voltage
when you select the Rx1K W or 150mA DC function.
• Always discharge filter capacitors in the power supply of
the circuit under test before you attach test probes.
• Always turn off power and disconnect the test leads
before you replace the batteries.
Download from Www.Somanuals.com. All Manuals Search And Download.
5
• Never operate the meter unless the battery cover is in
place and fully closed.
• Because many AC/DC sets have a potentially hot chas-
sis, be sure the top of your workbench and the floor
underneath it are made of non-conductive materials.
The multitester is fully calibrated and tested. Under normal
use, no further adjustment should be necessary. If the meter
should require repair, do not try to adjust it yourself. Take it to
your nearest Radio Shack store. Service by unauthorized per-
sonnel voids the warranty.
Download from Www.Somanuals.com. All Manuals Search And Download.
6
WARNING: USE EXTREME CAUTION IN USE OF THIS DE-
VICE. IMPROPER USE OF THIS DEVICE CAN RESULT IN
INJURY OR DEATH. FOLLOW ALL SAFEGUARDS SUG-
GESTED IN THE OWNER’S MANUAL IN ADDITION TO
NORMAL SAFETY PRECAUTIONS IN DEALING WITH
ELECTRICAL CIRCUITS. DO NOT USE THIS DEVICE IF
YOU ARE UNFAMILIAR WITH ELECTRICAL CIRCUITS
AND TESTING PROCEDURES. NOT FOR COMMERCIAL
OR INDUSTRIAL USE.
Download from Www.Somanuals.com. All Manuals Search And Download.
7
SPECIFICATIONS
Ranges
AC Voltage ................................................ 15V, 150V, 1000V
DC Voltage ................................................ 15V, 150V, 1000V
DC Current .................................................................150 mA
Resistance ...............................100K ohm (Center 3.5K ohm)
Accuracy
DC .............................................................. ± 3% of Full Scale
AC ............................................................. ± 4% of Full Scale
Resistance .....................................± 3% at Full Scale Length
Download from Www.Somanuals.com. All Manuals Search And Download.
8
Sensitivity
AC Voltage .......................................................2000 ohm/Volt
DC Voltage ......................................................2000 ohm/Volt
Operating Temperature......................... 32–109.4°F (0–43°C)
Storage Temperature ......................... –4–140°F (–20–60°C)
Power Requirements .................................................1.5 Volts
7
1
1
Dimensions........................................ 3 /8 ¥ 2 /2 ¥ 1 /4 Inches
(98 ¥ 64 ¥ 32 mm) (HWD)
Weight.................................................Approx. 3.7 oz. (105 g)
Download from Www.Somanuals.com. All Manuals Search And Download.
9
SPECIAL PANEL MARKINGS
We have added special markings to the panel to remind you
of the meter’s measurement limitations and important safety
precautions.
!
Follow the operating instructions given in this
owner’s manual.
500V
MAX
To avoid electric shock or damage to the meter,
do not connect the ground terminal to any source
of more than 500 volts with respect to earth
ground.
Download from Www.Somanuals.com. All Manuals Search And Download.
10
Be extra careful when you take measurements for
high voltage. Do not touch the meter’s test probe
ends.
Download from Www.Somanuals.com. All Manuals Search And Download.
11
INSTALLING A BATTERY
Your meter uses one AA battery for power. We recommend an
alkaline battery, such as Radio Shack Cat. No. 23-552/557.
WARNINGS:
• TO AVOID ELECTRIC SHOCK, DISCONNECT BOTH
TEST LEADS FROM ANY EQUIPMENT BEFORE YOU
REMOVE THE BATTERY.
• DO NOT OPERATE THE METER UNTIL YOU
REPLACE THE BATTERY AND CLOSE THE BACK
COVER.
Download from Www.Somanuals.com. All Manuals Search And Download.
12
Follow these steps to install the battery.
1. Set the function selector to OFF and remove the test
leads from all test circuits.
2. Use a Phillips screwdriver to remove the screw on the
back of the meter.
3. Remove the back of the meter.
Download from Www.Somanuals.com. All Manuals Search And Download.
13
4. Replace the weak battery with a fresh one, following the
correct polarity (+ and –).
5. Replace the back and secure it with the screw.
Note: If you cannot adjust the pointer to “0” on the scale when
you measure resistance (see “Measuring Resistance”), it is
time to replace the battery.
Download from Www.Somanuals.com. All Manuals Search And Download.
14
REPLACING THE FUSE
Your meter is protected by a 315 mA fuse.
WARNINGS:
• TO AVOID ELECTRIC SHOCK, DISCONNECT BOTH
TEST LEADS FROM ANY EQUIPMENT BEFORE YOU
REMOVE THE FUSE.
• DO NOT OPERATE THE METER UNTIL YOU
REPLACE THE FUSE AND CLOSE THE BACK
COVER.
Download from Www.Somanuals.com. All Manuals Search And Download.
15
CAUTION: FOR CONTINUED PROTECTION AGAINST
FIRE OR OTHER HAZARD, REPLACE THE FUSE ONLY
WITH A 315 mA, 250 V, 5 X 20 MM MINIATURE FUSE (CAT.
NO. 270-1046).
Follow these steps to replace the fuse.
Download from Www.Somanuals.com. All Manuals Search And Download.
16
1. Set the function selector to OFF and remove the test
leads from all test circuits.
2. Use a Phillips screwdriver to remove the screw on the
back of the meter.
3. Remove the back of the meter.
4. Replace the blown fuse with a new one.
5. Replace the back and secure it with the screw.
Download from Www.Somanuals.com. All Manuals Search And Download.
17
OPERATION
Cautions:
• Use only the same type of test leads that are supplied
with your meter. These test leads are rated for 1000
volts. Replacements are available at your local Radio
Shack store.
• When the meter is not in
use, always leave the
function selector set to
OFF
.
Download from Www.Somanuals.com. All Manuals Search And Download.
18
Warnings:
• Do not try to measure any voltage over the meter’s rat-
ing. Use extreme care when you use these high-voltage
ranges.
• Never connect the probe you plug into the negative (–)
terminal to a source of voltage more than 500 V. Doing
so can create a serious shock hazard.
Download from Www.Somanuals.com. All Manuals Search And Download.
19
MAKING ACCURATE MEASUREMENTS
For the most accurate reading, the temperature should be be-
tween 43°F and 74°F (6°C and 23°C) with an 80% maximum
relative humidity.
Keep the meter lying flat on a non-metallic surface. Also, use
a range setting that results in a reading in the upper third of the
meter scale.
Download from Www.Somanuals.com. All Manuals Search And Download.
20
For exact readings, look at the scale from the point where the
pointer and its reflection in the mirror come together.
Download from Www.Somanuals.com. All Manuals Search And Download.
21
Zero Adjustment
If the pointer does not normally rest exactly over 0 at the left
side of the ACV/DC.VMA scale, adjust the plastic screw in the
center of the tester face to bring the pointer to zero.
MEASURING VOLTAGE
WARNING: IF YOU ATTEMPT TO MEASURE A VOLTAGE
GREATER THAN 1000 VOLTS DC OR AC, YOU MIGHT
DAMAGE YOUR METER AND EXPOSE YOURSELF TO A
SEVERE SHOCK HAZARD.
Download from Www.Somanuals.com. All Manuals Search And Download.
22
Measuring High Voltages
When you measure voltage in a high-voltage circuit, do not try
to position both probes at once. Clamp one of the probes to
the circuit’s neutral or ground lead using a Radio Shack insu-
lated slip-on alligator clip (Cat. No. 270-354). Then probe for
voltages with the other probe. This helps prevent you from ac-
cidentally touching a hot wire.
Download from Www.Somanuals.com. All Manuals Search And Download.
23
Note: In AC wiring circuits, the ground lead is usually a bare,
green, or white lead and the hot wire is usually red, black, or
blue. In DC wiring circuits, the ground lead is usually a black
lead; the hot wire is usually red.
WARNING: NEVER CLAMP ONTO A HOT WIRE. IF YOU
CLAMP TO A HOT WIRE AND TOUCH THE OTHER
PROBE, YOU COULD RECEIVE AN ELECTRIC SHOCK.
Download from Www.Somanuals.com. All Manuals Search And Download.
24
Measuring DC Voltage
WARNING: IF YOU ATTEMPT TO MEASURE A VOLTAGE
ABOVE 1000 VOLTS DC, YOU MIGHT DAMAGE YOUR
METER AND EXPOSE YOURSELF TO A SEVERE SHOCK
HAZARD.
Download from Www.Somanuals.com. All Manuals Search And Download.
25
Follow these steps to measure DC voltage.
1. Set the function selector to one of the DC V positions.
Note: If you are not certain about the voltage level, start
with the 1000 DC V range. Then try the next lowest
range until the reading appears in the upper third of the
meter scale.
2. Connect the test probes to the circuit.
3. Read the voltage on the scale.
Download from Www.Somanuals.com. All Manuals Search And Download.
26
Measuring AC Voltage
WARNING: IF YOU ATTEMPT TO MEASURE A VOLTAGE
GREATER THAN 1000 VOLTS AC, YOU MIGHT DAMAGE
THE METER AND EXPOSE YOURSELF TO A SEVERE
SHOCK HAZARD.
Download from Www.Somanuals.com. All Manuals Search And Download.
27
Follow these steps to measure AC voltage.
1. Set the function selector to one of the AC.V positions.
Note: If you are not certain about the voltage level, start
with the 1000 AC V range. Then try the next lowest
range until the reading appears in the upper third of the
meter scale.
2. Connect the test probes to the circuit.
3. Read the voltage on the scale.
Download from Www.Somanuals.com. All Manuals Search And Download.
28
Measuring 3-Phase AC Voltage
This meter is primarily designed to measure household AC
voltages and is not intended for commercial or industrial use.
If you want to measure 3-phase, line-to-line voltages, please
note the following:
• Because of the dangers inherent in the measurement of
three-phase circuits, we strongly recommend against the
use of this meter for such applications.
• If you choose to make the measurements, use extreme
care. The actual voltage can be greater than the circuit’s
rated voltage (line-to-ground).
Download from Www.Somanuals.com. All Manuals Search And Download.
29
To determine the line-to-line voltage, multiply the rated line-to-
ground voltage by 1.732. For example, if the rated voltage is
600 volts, the line-to-line voltage would be:
600 Volts x 1.732 = 1039.2 Volts
In this example, the voltage exceeds the meter’s range and
should not be measured.
Download from Www.Somanuals.com. All Manuals Search And Download.
30
Measuring AC Voltage on a DC Source Bias
WARNING: NEVER MEASURE MORE THAN 30 VOLTS AC
ON A DC SOURCE BIAS.
When an AC voltage has been superimposed on a DC source
bias, you cannot take ordinary measurements. The readings
wander on the scale and are not accurate.
However, if you know the approximate AC voltage and it does
not exceed 30 volts AC, you can measure it by connecting a
0.1 mF, 100-volt polyester film capacitor in series with the pos-
itive (+) voltage source and the meter’s red probe.
Download from Www.Somanuals.com. All Manuals Search And Download.
31
MEASURING DC CURRENT
WARNING:
NEVER CONNECT THE TEST LEADS TO A
SOURCE OF UNKNOWN VOLTAGE WHEN YOU HAVE SET
THE FUNCTION SELECTOR TO THE 150 mA DC POSI-
TION.
1. Set the function selector to 150 mA DC.
Download from Www.Somanuals.com. All Manuals Search And Download.
32
2. Break the electrical path for the circuit in which you want
to measure current. Then connect the black test probe to
the negative side and the red test probe to the positive
side of the circuit. Read the results on the scale.
Download from Www.Somanuals.com. All Manuals Search And Download.
33
MEASURING RESISTANCE
WARNINGS:
• NEVER CONNECT THE TEST LEADS TO A SOURCE
OF VOLTAGE WHEN YOU HAVE SET THE FUNCTION
SELECTOR TO THE Rx1K W POSITION.
• BE SURE THAT THE CIRCUIT UNDER TEST HAS ALL
POWER REMOVED AND THAT ANY ASSOCIATED
CAPACITORS ARE FULLY DISCHARGED BEFORE
YOU MAKE A RESISTANCE MEASUREMENT.
Download from Www.Somanuals.com. All Manuals Search And Download.
34
1. Disconnect power from the circuit you are testing. Then
unplug the power cord and remove any batteries.
W
2. Set the function selector to Rx1K . Touch the probes
together and adjust the OHMS ADJ. control to bring the
pointer to the “0” position on the scale.
3. Touch the probes across the circuit or component you
are testing. Read the results on the scale.
Download from Www.Somanuals.com. All Manuals Search And Download.
35
Notes:
• When you measure the resistance of a component in a
circuit, disconnect one side of the component you are
testing. This prevents other components in the circuit
from interfering with the reading.
• When you try to identify cathode and anode ends or the
type of transistor (PNP or NPN), the actual polarity of the
meter’s voltage is the opposite of the polarity suggested
by the test probes’ color. The red test probe is the nega-
tive source, and the black test probe is positive.
Download from Www.Somanuals.com. All Manuals Search And Download.
36
MAINTENANCE
Your Radio Shack 8-Range Multitester is an example of supe-
rior design and craftsmanship. The following suggestions will
help you care for the meter so you can enjoy it for years.
• Keep the meter dry. If it gets wet, wipe it dry immediately.
Liquids might contain minerals that can corrode the elec-
tronic circuits.
• Use and store the meter only in normal temperature
environments. Temperature extremes can shorten the
life of electronic devices, damage batteries, and distort
or melt plastic parts.
Download from Www.Somanuals.com. All Manuals Search And Download.
37
• Handle the meter gently and carefully. Dropping it can
damage the circuit boards and can cause it to work
improperly.
• Keep the meter away from dust and dirt, which can
cause premature wear of parts.
• Wipe the meter with a damp cloth occasionally to keep it
looking new. Do not use harsh chemicals, cleaning sol-
vents, or strong detergents to clean the meter.
• Use only a fresh battery of the recommended size and
type. Always remove an old or weak battery. It can leak
chemicals that can destroy electronic circuits.
Download from Www.Somanuals.com. All Manuals Search And Download.
38
Modifying or tampering with the meter’s internal components
can cause a malfunction and might invalidate its warranty. If