Quatech MP3 Player Accessories QSC 100 User Guide

QSC-100  
Two Channel RS-232 Asynchronous  
Communications Adapter  
`
for PCI bus  
User's Manual  
QUATECH, INC.  
5675 Hudson Industrial Parkway  
Hudson, Ohio 44236  
TEL: (330) 655-9000  
FAX: (330) 655-9010  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1998 -2000, Quatech, Inc.  
NOTICE  
The information contained in this document cannot be reproduced in any form without  
the written consent of Quatech, Inc. Likewise, any software programs that might accompany this  
document can be used only in accordance with any license agreement(s) between the purchaser  
and Quatech, Inc. Quatech, Inc. reserves the right to change this documentation or the product to  
which it refers at any time and without notice.  
The authors have taken due care in the preparation of this document and every attempt  
has been made to ensure its accuracy and completeness. In no event willQuatech, Inc. be liable  
for damages of any kind, incidental or consequential, in regard to or arising out of the  
performance or form of the materials presented in this document or any software programs that  
might accompany this document.  
Quatech, Inc. encourages feedback about this document. Please send any written  
comments to the Technical Support department at the address listed on the cover page of this  
document.  
DOS, Windows ME, Windows 2000, Windows 98, Windows 95, Windows NT are trademarks or registered  
trademarks of Microsoft Corporation. OS/2 is a registered trademark of IBM Corporation. All other trademarks or  
registered trademarks are property of their respective owners.  
Declaration of Conformity  
Manufacturer's Name:  
Quatech Inc.  
Manufacturer's Address:  
5675 Hudson Industrial Parkway  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hudson, Ohio 44236 (USA)  
89/336/EEC  
Application of Council Directive:  
Standards to which  
Conformity is Declared:  
* EN50081-1 (EN55022,  
EN60555-2, EN60555-3)  
* EN50082-1 (IEC 801-2,  
IEC 801-3, & IEC 801-4)  
Type of Equipment:  
Equipment Class:  
Information Technology  
Equipment  
Commercial, Residential, & Light  
Industrial  
Product Name:  
Model Number :  
PCI Quad Serial Communications Card  
QSC-100/IND  
1 General Information  
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4  
1.1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5  
1.1.1 "IND" Option --- Surge Suppression Upgrade . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5  
2 Hardware Configuration  
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6  
2.1 Factory Default Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6  
2.2 Enable Scratchpad Register (SPAD, J6) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6  
2.3 Force High-Speed UART Clock (X2, X4, or X8, J3-J5) . . . . . . . . . . . . . . . . . . . . . . . . 7  
3 Hardware Installation  
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8  
4 Address Map and Special Registers  
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9  
4.1 Base Address and Interrupt Level (IRQ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4.2 Enabling the Special Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10  
4.3 Interrupt Status Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10  
4.4 Options Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11  
4.4.1 Enhanced Serial Adapter Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11  
4.4.2 Clock Rate Multiplier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12  
5 Windows Configuration  
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13  
5.1 Windows Millennium . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13  
5.2 Windows 2000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14  
5.3 Windows 1998 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15  
5.4 Windows 1995 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16  
5.5 Viewing Resources with Device Manager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18  
5.6 Windows NT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19  
6 DOS and Other Operating Systems  
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20  
6.1.1 QTPCI.EXE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20  
7 OS/2  
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23  
8 External Connections  
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24  
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26  
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27  
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29  
9 PCI Resource Map  
10 Specifications  
11 Troubleshooting  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1 General Information  
The Quatech, Inc. QSC-100 provides four RS-232 asynchronous serial communication  
interfaces for IBM-compatible personal computer systems using thePCI expansion bus. The  
QSC-100 uses Quatech's new Enhanced Serial Adapter design. Legacy serial port data rates are  
limited to a maximum of 115,200 bits per second. Quatech Enhanced Serial Adapters can  
achieve data rates as high as 921,600 bits per second.  
As a PCI device, the QSC-100 requires no hardware configuration. The card is  
automatically configured by the computer's BIOS or operating system. The four serial ports  
share a single interrupt line and are addressed in a contiguous block of 32 bytes. A special  
interrupt status register is provided to help software to manage the shared interrupt.  
The QSC-100's serial ports are using 16750 Universal Asynchronous  
Receiver/Transmitters (UARTs). These UARTs contain hardware buffers (FIFOs) which reduce  
processing overhead and allow higher data rates to be achieved. The 16750 contains a 64-byte  
FIFO and can transmit and receive data at a rate of up to 921,600 bits per second and is  
recommended for heavy multitasking environments and for applications involving high data  
rates. The larger FIFO allows each read or write access to theUART to move more data,  
resulting in fewer interrupts and less processor time spent servicing the UART.  
The QSC-100 is supported under several popular operating systems and environments.  
Contact the sales department for details on current software offerings. Most device drivers are  
Quatech serial device drivers for Windows 95, Windows NT, 98, 2000, Millennium and OS/2  
provide support for the UART's 16750 mode.  
Quatech QSC-100 User's Manual  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.1 Features  
The standard QSC-100 implements each of its communication channels with a 16750  
UART and uses standard line driver and receiver components. For improved performance and  
industrial-grade reliability.  
1.1.1 "IND" Option --- Surge Suppression Upgrade  
The "IND" upgrade provides the protection essential for reliable use in an industrial  
environment. Each communication line has a surge suppresser capable of sustaining up to 40A  
20us peak transient surges, a clamping voltage of 30V and a peak energy dissipation of 0.1  
Joules.  
Part Number  
QSC-100  
IND Option  
no  
QSC-100IND  
yes  
Figure 1 --- QSC-100 Product Series Summary  
Quatech QSC-100 User's Manual  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
2 Hardware Configuration  
The QSC-100 is automatically configured at boot time by the computer's BIOS or  
operating system. There are no required switches or jumpers to set for installation.  
This chapter lists a number of optional jumper settings that control various hardware  
features. Jumpers J3-J6 are grouped together at the end of the board opposite the D-37  
connector. Any changes from the factory default should be made before installing theQSC-100  
in the computer.  
2.1 Factory Default Configuration  
Figure 2 shows the jumper configuration as shipped from the factory, with two spare  
jumpers applied in neutral positions. Remove one or both and apply as shown in following  
sections to set optional features.  
J3  
J4  
J5  
X2  
X4  
X8  
SPAD  
J6  
Figure 2 --- Factory default jumper configuration  
2.2 Enable Scratchpad Register (SPAD, J6)  
In the default configuration, an Interrupt Status Register and an Options Register(see  
page 0) replace the scratchpad (base address + 7) of each UART. If the SPAD jumper is applied  
as in Figure 3, the UART scratchpad registers are enabled, and the Interrupt Status Register and  
the Options Register are not available.  
J3  
J4  
J5  
J6  
X2  
X4  
X8  
SPAD  
Figure 3 --- Enable scratchpad registers  
Quatech QSC-100 User's Manual  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.3 Force High-Speed UART Clock (X2, X4, or X8, J3-J5)  
These jumpers force an increase of the UART input clock frequency by a factor of two,  
four, or eight. This feature can allow legacy software to use baud rates above 115,200 bits per  
second. It is also useful if the serial port device driver does not directly support setting the higher  
baud rates through the Options Register.  
If one of these jumpers is applied, it overrides any value written to the Options Register to  
set the clock multiplier by software. The effective baud rate will be either two, four, or eight  
times the value for which the UART itself is programmed.  
The factory default is none of these jumpers applied, which allows for software control of  
the clock multiplier via the Options Register. The Options Register powerup default is for a  
standard times-1 clock of 1.8432 MHz for compatibility with standard serial ports.  
J3  
J4  
J5  
J3  
J4  
J5  
X2  
X2  
X4  
X4  
X8  
X8  
SPAD  
SPAD  
J6  
J6  
Force times-two clock  
Baud rates up to 230.4 kbps  
Factory default  
software control  
J3  
J3  
J4  
J5  
X2  
X2  
J4  
J5  
X4  
X4  
X8  
X8  
SPAD  
SPAD  
J6  
J6  
Force times-eight clock  
Force times-four clock  
Baud rates up to 460.8 kbps  
Baud rates up to 921.6 kbps  
Figure 4 --- Clock multiplier jumper options  
Quatech QSC-100 User's Manual  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
3 Hardware Installation  
1. Turn off the power of the computer system in which the QSC-100 is to be installed.  
2. Remove the system cover according to the instructions provided by the computer  
manufacturer.  
3. Make any desired optional jumper setting changes.  
4. Install the QSC-100 in any empty PCI expansion slot. The board should be secured by  
installing the Option Retaining Bracket (ORB) screw.  
5. Replace the system cover according to the instructions provided by the computer  
manufacturer.  
6. Attach and secure the cable connectors to the desired equipment.  
7. Turn on the power of the computer system.  
The output of the QSC-100 is a 37-pin D-connector. A cable is provided to convert the  
D-37 into four standard male D-25 connectors with all control signals provided to each port  
(RTS, DTR, CTS, DSR, DCD, and RI).  
Clock multiplier/  
scratchpad select  
J3  
J4  
J5  
J6  
X2  
X4  
X8  
SPAD  
Figure 5 --- Jumper/connector locations  
Quatech QSC-100 User's Manual  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
4 Address Map and Special Registers  
This chapter explains how the four UARTs and special registers are addressed, as well as  
the layout of those registers. This material will be of interest to programmers writing driver  
software for the QSC-100.  
4.1 Base Address and Interrupt Level (IRQ)  
The base address and IRQ used by the QSC-100 are determined by the BIOS or operating  
system. Each serial port uses 8 consecutive I/O locations. The four ports reside in a single block  
of I/O space in eight byte increments, for a total of 32 contiguous bytes, as shown inFigure 5.  
Port  
I/O Address Range  
Serial 1  
Serial 2  
Serial 3  
Serial 4  
Base Address + 0  
Base Address + 8  
to Base Address + 7  
to Base Address + 15  
Base Address + 16 to Base Address + 23  
Base Address + 24 to Base Address + 31  
Figure 6 --- Port Address Map  
All four serial ports share the same IRQ. The QSC-100 signals a hardware interrupt  
when any port requires service. The interrupt signal is maintained until no port requires service.  
Interrupts are level-sensitive on the PCI bus.  
The base address and IRQ are automatically detected by the device driversQuatech  
supplies for various operating systems. For cases where no device driver is available, such as for  
operation under DOS, Quatech supplies the "QTPCI" DOS software utility for manually  
determining the resources used. See page 0 for details.  
Quatech QSC-100 User's Manual  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
4.2 Enabling the Special Registers  
The QSC-100 contains two unique registers, an Interrupt Status Register and an Options  
Register. These registers are enabled when the SPAD jumper (J6) is removed (factory default).  
They replace the UART Scratchpad Register on accesses to register address 7.  
The Interrupt Status Register and Options Register are accessed through the scratchpad  
location of any UART. The DLAB bit of the UART (Line Control Register, bit 7) is used to  
select between the two registers. The most recent write of a DLAB bit in anyUART selects  
between the two registers as shown in Figure 6.  
Register selected for  
DLAB Bit SPAD Jumper  
address 7 accesses  
0
1
X
removed  
removed  
applied  
Interrupt Status Register  
Options Register  
Scratchpad Registers  
Figure 7 --- DLAB bit selects between special registers  
4.3 Interrupt Status Register  
The read-only Interrupt Status Register can be used to quickly identify which serial ports  
require servicing after an interrupt. Reading the Interrupt Status Register will return the interrupt  
status of the entire QSC-100, as shown in Figure 7. The individual bits are cleared as the  
interrupting ports are serviced. The interrupt service routine should ensure that the interrupt  
status register reads zero before exiting.  
Bit  
Description  
0 (not used)  
7 (MSB)  
6
5
4
3
2
1
0
0 (not used)  
0 (not used)  
0 (not used)  
Port 4 --- 1 if interrupt pending  
Port 3 --- 1 if interrupt pending  
Port 2 --- 1 if interrupt pending  
Port 1 --- 1 if interrupt pending  
Figure 8 --- Interrupt Status Register  
Quatech QSC-100 User's Manual  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4.4 Options Register  
The Options Register allows software to identify the QSC-100 as a Quatech Enhanced  
Serial Adapter. It also allows software to set the UART clock rate multiplier. Figure 8 shows  
the structure of the Options Register.  
The powerup default of the Options Register is all bits zero.  
Bit  
Name  
Description  
ID bit 1  
7 (MSB)  
ID1  
6
5
4
3
2
1
0
ID0  
ID bit 0  
-
(reserved, 0)  
-
-
(reserved, 0)  
(reserved, 0)  
-
(reserved, 0)  
RR1  
RR0  
Clock rate multiplier bit 1  
Clock rate multiplier bit 0  
Figure 9--- Options Register bit definitions  
4.4.1 Enhanced Serial Adapter Identification  
The ID bits are used to identify the QSC-100 as a Quatech Enhanced Serial Adapter.  
Logic operations are performed such that the values read back from these bits will not necessarily  
be the values that were written to them. Bit ID1 will return the logical-AND of the values  
written to ID[1:0], while bit ID0 will return their exclusive-OR.  
Software can thus identify a Quatech Enhanced Serial Adapter by writing the ID bits with  
the patterns shown in the "write" column of Figure 9, then reading the bits and comparing the  
result with the patterns in the "read" column. Matching read patterns verify the presence of the  
Options Register.  
Write  
Read  
ID1 ID0 ID1 ID0  
0
0
1
1
0
1
0
1
0
0
0
1
0
1
1
0
Figure 10 --- ID bit write/read table  
4.4.2 Clock Rate Multiplier  
Quatech QSC-100 User's Manual  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A standard RS-232 serial port operates at a clock speed of 1.8432 MHz. In order to  
achieve higher data rates, Quatech Enhanced Serial Adapters can operate at two times, four  
times, or even eight times this standard clock speed. This is controlled by the clock rate  
multiplier bits in the Options Register.  
Software can determine the UART clock frequency by reading the clock rate multiplier  
bits RR1 and RR0 in the Options Register as shown in Figure 10. RR1 and RR0 can be set by  
writing to the Options Register if the X2, X4, and X8 jumpers (J3-J5) are all removed. If one of  
these jumpers is applied, the RR1 and RR0 bits are forced to the appropriate value. Reading the  
Options Register will always return the clock rate multiplier at which the board is operating.  
Clock Rate  
Multiplier  
X1  
(default)  
X2  
UART Clock  
Frequency  
Maximum Data  
Rate  
RR1 RR0  
0
0
1.8432 MHz  
115.2 kbaud  
0
1
1
1
0
1
3.6864 MHz  
7.3728 MHz  
14.7456 MHz  
230.4 kbaud  
460.8 kbaud  
921.6 kbaud  
X4  
X8  
Figure 11 --- Rate Register bit definition  
At powerup and reset, the Options Register is initialized to 0. The QSC-100 will thus  
powerup in the x1 mode with software control of the clock rate multiplier enabled as long as the  
X2, X4, and X8 jumpers are not installed.  
Software can control high baud rates through a combination of changing the clock rate  
multiplier and the UART baud rate divisor. For example, a baud rate of 230.4 kbps could be  
achieved by setting the clock rate multiplier to X2 mode (or by applying the X2 jumper) and  
setting a software application for 115.2 kbps.  
Quatech QSC-100 User's Manual  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5 Windows Configuration  
5.1 Windows Millennium  
1. After inserting the QSC 100 for the first time the "Add New Hardware Wizard" will  
begin. Select "Search for the best driver for your device.". Check the "Removable media" and  
"Specify location" box. Click the "Next" button.  
3. Window will locate the proper INF file and copy the file from the CD. Click  
the "Next" button.  
4. The final dialog screen will verify the file copy from the diskette. Click the  
"Finish" button.  
Quatech QSC-100 User's Manual  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5.2 Windows 2000  
1.  
After inserting a QSC-100 for the first time, the "Add New Hardware Wizard will  
appear at start up. Click the "OK" button.  
2. The following dialog box insert the Quatech COM CD (shipped with the device).  
Click the "OK" button.  
4.  
5.  
The following dialog box will display the appropriate INF file on the diskette in  
drive. Click the "OK" button.  
Window will copy the INF file from the diskette and display a final dialog  
indication that the process is complete. Click the "Finish" button.  
5.3 Windows 1998  
Quatech QSC-100 User's Manual  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.  
After inserting a QSC-100 for the first time, the "Add New Hardware Wizard will  
appear at start up. Click the "Next" button.  
2. Select "Search for the best driver for you device". Click the "Next" button.  
3.  
On the next dialog, select the "CD-ROM DRIVE" check box. Insert the Quatech  
COM CD (shipped with the device) into the CD-ROM DRIVE.  
Click the "Next" button.  
Quatech QSC-100 User's Manual  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4.  
5.  
The following dialog box will display the appropriate INF file on the CD in  
drive. Click the "Next" button.  
Window will copy the INF file from the diskette and display a final dialog  
indication that the process is complete. Click the "Finish" button.  
5.4 Windows 1995  
The following instructions provide step-by-step instructions on installing the  
QSC-100 in Windows 95 using the "New Hardware Found" wizard.  
1. After booting the computer with a newly-installed QSC-100, the "New Hardware Found"  
dialog box will appear. If you have never installed a Quatech PCI communications  
adapter before, the dialog box may simply indicate that it has found a "PCI Card."  
2. Select the radio button for "Driver from disk provided by hardware manufacturer." Click  
the "OK" button to continue.  
3. An "Install From Disk" dialog box should pop up. Insert the CD with the Quatech INF  
files on it, select the correct drive letter, and click the "OK" button. Windows 95  
automatically browses CD for an INF file that defines configurations for Multi-function  
Adapters. If no INF files are found, click the "Browse" button and search theWin95 sub  
directory on the installation diskette. You are not required to select the file name. After  
finding the directory containing the INF files, Windows 95 will choose the correct file.  
4. The "New Hardware Found" dialog box will appear again, this time for an "Unknown  
Device."  
Quatech QSC-100 User's Manual  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. Again select the radio button for "Driver from disk provided by hardware manufacturer."  
Click the "OK" button to continue.  
6. Another "Install From Disk" dialog box will pop up. The path should already be pointing  
to the Quatech CD. Click the "OK" button to continue.  
7. You should now see the "Copying Files" dialog box as Windows 95 copies the driver  
files from the diskette.  
8. The installation utility will ask for your Windows 95 installation CD. Serial  
communication ports require two drivers supplied by Microsoft to function:  
SERIAL.VXD and SERIALUI.DLL. Insert the disk or CD and click "OK".  
NOTE:  
You may be able to skip this step if you are certain that your system has the latest  
version of these files installed. If you do not have your Windows 95 install disks  
immediately available, click "OK" anyway. A dialog box appears with an option  
to Skip the files. Click the Skip button and the files will not be installed. This is  
all right if the latest version of these drivers are currently in the  
\WINDOWS\SYSTEM directory.  
9. The "New Hardware Found" dialog will repeat for each of the serial ports on the  
QSC-100 as each port is registered with Windows 95.  
10. Installation is complete.  
Windows 95 maintains a registry of all known hardware installed in your computer.  
Inside this hardware registry Windows 95 keeps track of all of your system resources, such as I/O  
locations, IRQ levels, and DMA channels. The "Add New Hardware Wizard" utility in Windows  
95 was designed to add new hardware and update this registry.  
An "INF" configuration file is included with the QSC-100 to allow easy configuration in  
the Windows 95 environment. Also a custom Windows 95 serial device driver is included with  
the QSC-100 to support the use of the 16750 UART's 64 byte FIFO. Windows 95 uses the "INF"  
file to determine the system resources required by the QSC-100, searches for available resources  
to fill the boards requirements, and then updates the hardware registry with an entry that allocates  
these resources.  
5.5 Viewing Resources with Device Manager  
The following instructions provide step-by-step instructions on viewing resources used by  
the QSC-100 in Windows using the "Device Manager" utility. Select Start|Help from within  
Windows 95 for additional information on this utility.  
1. Double click the "System" icon inside the Control Panel folder. This opens up the  
System Properties box.  
Quatech QSC-100 User's Manual  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Click the "Device Manager" tab located along the top of the System Properties box. This  
lists all hardware devices registered inside the Windows 95 registry. Additional  
information is available on any of these devices by click on the device name and then  
selecting the "Properties" button.  
3. Double click the device group "Multi-function Adapters". The QSC-100 model name  
should appear in the list of Multi-function adapters.  
4. Double click the QSC-100 model name and a properties box should open for the  
hardware adapter.  
5. Click the "Resources" tab located along the top of the properties box to view the  
resources Windows has allocated for the QSC-100 match the hardware configuration.  
Because PCI is a true plug-and-play bus, do not attempt to modify the configuration  
values listed. Click "Cancel" to exit without making changes.  
6. The QSC-100 serial ports are also listed under the group Ports (COM and LPT).  
Windows does not assign COM1-COM4 to ports addressed at nonstandard locations.  
The QSC-100 ports will be enumerated starting with COM5 (or higher) even if lower  
logical numbers are available.  
7. Select any of the Quatech Serial Ports listed under the group Port (COM and LPT) and  
click the "Properties" button. This action opens a properties dialog for the specific COM  
port on the QSC-100.  
8. Click the "Port Settings" tab and then click the "Advanced" button. The QSC-100 driver  
will display a custom Advanced Port Settings control, which allows the ports UART  
compatibility mode and FIFO threshold levels to be configured. The threshold values of  
full-scale for the transmit buffer and 3/4-scale for the receive buffer shown below are  
optimal for most applications. Note that the FIFO option for each of the QSC-100's four  
ports is configured independently.  
9. Use the Logical COM Port names to access the serial ports on your QSC-100 through  
your software applications. Note: The Logical COM Port name is assigned to your ports  
by Windows 95. This name is required by a Windows application when accessing a  
particular port.  
5.6 Windows NT  
Device drivers for Windows NT and OS/2 are also available for the QSC-100. The board  
can be used under DOS and other operating systems as well in many circumstances. The  
software described below can be downloaded from the Quatech web site if it did not come with  
the board.  
Quatech QSC-100 User's Manual  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The Windows NT device driver is installed by running the SETUP program. Up to 256  
serial ports are supported. There is a command line-based configuration utility which is used for  
adding PCI bus and ISA bus serial ports. Please refer to the documentation included with the  
device driver on the Quatech COM CD for full installation and configuration details  
Quatech QSC-100 User's Manual  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6 DOS and Other Operating Systems  
The QSC-100 is not a direct drop-in replacement for a legacy serial port because its base  
address and IRQ 3 (COM2), etc. Rather, the system BIOS assigns the address and the IRQ in a  
plug-and-play fashion at boot time. Software which is to use the QSC-100 must be able to  
accommodate any valid assignments of these resources  
For Windows and OS/2, the Quatech device drivers determine what the resource  
assignments are and proceed accordingly. In other cases, however, the user must intervene. The  
discussion below will center on DOS, but the concepts can be applied to other operating systems  
as well.  
Many DOS applications support user configuration of the base address and IRQ of a  
serial port. Such applications can generally make use of the QSC-100. Older applications, as  
well as some custom software, may use hard-coded standard legacy serial port addresses. These  
applications will require modifications if they are to use the QSC-100.  
Custom applications for which the customer has source code can be modified to make  
just a few PCI BIOS function calls to obtain all the necessary configuration information. The  
PCI BIOS specification can be obtained from the PCI Special Interest Group. Contact Quatech  
technical support for more information.  
6.1.1 QTPCI.EXE  
Quatech's "QTPCI" utility supplies the information required when modifying theserial  
port settings of the application. This program should be run from real DOS, not in a Windows  
DOS box.  
Figure 13 shows the Basic Mode display for the QSC-100 after the "Q" key has been  
pressed. In this example, the QSC-100 uses I/O base address FF80 hex and IRQ 11. The  
hardware revision of the QSC-100 is also displayed. Pressing the "N" key will show similar  
information for all non-Quatech PCI devices in the system, including those devices integrated on  
the motherboard.  
The QTPCI program is capable only of displaying the PCI configuration. It cannot be  
used to make changes.  
Quatech QSC-100 User's Manual  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Quatech PCI Configuration Information Display Software  
Version 1.00  
INSTRUCTIONS:  
------------------------  
Press keys listed in the menu at the bottom of the screen.  
This program only displays information. It cannot make changes.  
Numbers preceeded by "0x" are hexadecimal.  
PCI BIOS detected, version 2.10  
Quatech PCI adapters detected  
---------------------------------------------  
QSC-100 Four-port RS-232 adapter  
Uses IRQ 11  
(Hardware Revision A1)  
Base addr 1 = 0xff80  
_
I/O  
M - Change to Expert Mode  
Q - Quatech PCI adapters  
N - Other PCI devices  
X - EXIT  
Figure 14 --- QTPCI.EXE Basic Mode display  
Figure 14 shows the Expert Mode display for the QSC-100 after the "Q" key has been  
pressed. The information from the Basic Mode display is presented along with more details such  
as the Vendor and Device IDs, PCI Class Code, size of memory and I/O regions, etc. Pressing  
the "N" key will show similar information for all non-Quatech PCI devices in the system,  
including those devices integrated on the motherboard. In this example, the "Base addr 0"  
resource is reserved.  
Quatech QSC-100 User's Manual  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
For users interested in even more details, PCI BIOS information can be displayed by  
pressing the "B" key. Pressing the "I" key displays thePCI interrupt routing table.  
Quatech PCI Configuration Information Display Software  
Version 1.00  
Quatech PCI adapters detected  
---------------------------------------------  
QSC-100 Four-port RS-232 adapter  
Vendor ID 0x135c, Device id 0x0050 found in slot 0x04 on bus 0x00  
Device/function code = 0x98, Revision ID = 0x01 (Hardware revision A1)  
PCI Class Code = 0x070200 Communications controller, multiport serial  
Subsystem Vendor ID 0x135c, Subsystem Id 0x0050  
INTA# mapped to IRQ 11 (route 0x61)  
Base addr 0 = 0xfc00  
Base addr 1 = 0xff80  
_
I/O  
I/O  
0X80 bytes allocated  
0X20 bytes allocated  
M - Change to Basic Mode  
B - PCI BIOS details  
I - Interrupt routing details  
Q - Quatech PCI adapters  
N - Other PCI devices  
X - EXIT  
Figure 15 --- QTPCI.EXE Expert Mode display  
Quatech QSC-100 User's Manual  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7 OS/2  
The OS/2 device driver supports up to 32 serial ports in a system. Installation is a  
manual, but simple, process. Please refer to the read me documentation included on the Quatech  
COM CD with the device driver for full installation and configuration details.  
Quatech QSC-100 User's Manual  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8 External Connections  
RS-232-C devices are classified by their function as either Data Terminal Equipment  
(DTE) or Data Communication Equipment (DCE). Generally, data terminal equipment is  
defined as the communication source and data communication equipment is defined as the device  
that provides a communication channel between two DTE-type devices.  
Terminal  
DTE  
Modem  
DCE  
RS-232-C  
RS-232-C  
Telephone  
line  
Terminal  
DTE  
Modem  
DCE  
Figure 16 --- Use of DTEs and DCEs in a communications link  
DTE- and DCE-type devices have complementary pinouts to allow terminals and  
modems to be connected directly using a one-to-one cable as shown in Figure 16. In many  
applications, DCEs are unnecessary, and in these cases a cable called a "null modem cable" or  
"modem eliminator cable" is used to directly connect two DTE-type devices. A typical null  
modem cable is also shown in Figure 16.  
(3)  
(2)  
(4)  
(5)  
(20)  
(6)  
(8)  
(22)  
(7)  
(3)  
(2)  
(4)  
(5)  
(20)  
(6)  
(8)  
(22) RI  
(7)  
RxD  
TxD  
RTS  
CTS  
DTR  
DSR  
DCD  
RI  
(3)  
(2)  
(4)  
(5)  
(20)  
(6)  
(8)  
(22)  
(7)  
RxD  
TxD  
(3)  
(2)  
(4)  
(5)  
(20)  
(6)  
(8)  
(22)  
(7)  
RxD  
TxD  
RTS  
CTS  
DTR  
DSR  
DCD  
RI  
TxD  
RxD  
CTS  
RTS  
DSR  
DTR  
DCD  
RI  
RTS  
CTS  
DTR  
DSR  
DCD  
GND  
GND  
GND  
GND  
Typical DTE-to-DCE cable  
Typical DTE-to-DTE null modem cable  
Figure 17 --- Cabling requirements for RS-232-C devices  
(cables using 25-pin connectors shown)  
Quatech QSC-100 User's Manual  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The QSC-100 is a DTE device which connects to peripheral equipment through a single  
female D-37 connector, or using the adapter cable, four male D-25 connectors. The standard  
serial port connections are listed in Figure 17.  
Port 1  
Port 2  
Port 3  
Port 4  
RS-232  
Signal  
D-37 D-25 D-37 D-25 D-37 D-25 D-37 D-25  
TxD  
RxD  
RTS  
CTS  
DTR  
DSR  
DCD  
RI  
24  
5
2
3
10  
28  
9
2
3
33  
14  
32  
13  
30  
31  
11  
29  
12  
2
3
19  
37  
18  
36  
16  
17  
34  
15  
35  
2
3
23  
4
4
4
4
4
5
27  
7
5
5
5
21  
22  
2
20  
6
20  
6
20  
6
20  
6
8
8
25  
6
8
8
8
20  
3
22  
7
22  
7
22  
7
22  
7
GND  
26  
Figure 18 --- QSC-100 connector pinouts  
1
2
3
4
13  
25  
24  
23  
22  
21  
20  
19  
18  
17  
16  
15  
14  
20  
21  
22  
23  
24  
25  
12  
11  
10  
9
5
6
7
8
7
26  
27  
28  
29  
30  
31  
32  
33  
34  
35  
36  
37  
8
9
6
5
10  
11  
12  
4
3
2
1
13  
14  
15  
16  
17  
18  
19  
D-25 connector  
(using adapter cable)  
D-37 connector  
(dashed lines delineate channels)  
Figure 19 --- QSC-100 output connectors  
Quatech QSC-100 User's Manual  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
9 PCI Resource Map  
Listed below are the PCI resources used by the QSC-100. Such information may be of  
use to customers writing their own device drivers or other custom software. A detailed  
description of the QSC-100's UARTs is available on the Quatech web site.  
(all numbers in hex)  
PCI Vendor ID:  
PCI Device ID:  
0x135C  
0x0010  
Quatech, Inc.  
QSC-100  
PCI Class Code  
Base class:  
Subclass:  
0x07  
0x02  
0x00  
Simple communications controller  
Multiport serial controller  
Interface:  
IRQ sourced by:  
Base address 0:  
Base address 1:  
INTA#  
0x80 bytes I/O  
0x20 bytes I/O  
Reserved region  
Serial ports  
Port 1 at offset 0x00  
Port 2 at offset 0x08  
Port 3 at offset 0x10  
Port 4 at offset 0x18  
Quatech QSC-100 User's Manual  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
10 Specifications  
Bus interface:  
PCI, 32-bit bus, 5-volt only  
IBM-compatible computers  
Dimensions:  
approx. 5.0" x 3.7"  
Serial ports  
Controller:  
Interface:  
16750 with 64-byte FIFOs  
One female D-37 connector  
Four male D-25 connectors  
using adapter cable  
Transmit drivers:  
SN75150 or compatible  
High-level output:+5V min, +8V typical  
Low-level output: -5V max, -8V typical  
Switching speed  
low-to-high:  
1.4 µs with 2500 pF load  
40 ns with 15 pF load  
1.5 µs with 2500 pF load  
20 ns with 15 pF load  
high-to-low:  
Receive buffers:  
MC1489 or compatible  
High-level input: +3V to +13V  
Low-level input:  
-3V to -13V  
Switching speed: 120 ns typical, 175 ns max  
Power requirements  
+5  
volts:  
approx. 260 mA  
approx. 35 mA  
+/-12 volts:  
Temperature:  
operating 0° to 70°  
storage -50° to 80°  
Humidity:  
10% to 90%  
Quatech QSC-100 User's Manual  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Maximum Load (pF)  
Data Rate  
(kbaud)  
4%  
trans  
time  
N/A  
100  
330  
800  
10%  
trans  
time  
100  
430  
900  
15%  
trans  
time  
300  
670  
1100  
3300  
20%  
trans  
time  
430  
900  
1630  
4300  
25%  
trans  
time  
470  
1100  
2000  
4800  
921.6  
460.8  
230.4  
115.2  
1570  
Note 1: The signal transition time ratio is defined as the percentage of the unit interval or  
bit time (the inverse of the data rate) that is occupied by the signal transitioning from -3V  
to +3V. The EIA/TIA-232-E standard defines a maximum signal transition time ratio of  
4%; most RS-232 receivers will recognize signal transitions with much larger ratios.  
With a 4% signal transition time ratio, EIA/TIA-232-E is limited to a theoretical data rate  
of 200 kbaud. If maximum signal transition time ratio is extended to 10%, 15%, 20%, or  
even 25%, the maximum data rate achievable using EIA/TIA-232-E can be increased past  
200 kbaud.  
Note 2: A typical value for capacitance per foot of standard cable is 50 pF/ft.  
Quatech QSC-100 User's Manual  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
11 Troubleshooting  
Listed here are some common problems and frequent causes of those problems. If the  
information here does not provide a solution, contact Quatech technical support.  
Any unauthorized repairs or modifications will void the QSC-100's warranty.  
Computer will not boot up.  
1. Is the QSC-100 properly inserted? Remove the card and try again. Perhaps try a different  
expansion slot.  
2. Ensure that an ISA-bus card is not using the same IRQ that the PCI BIOS tries to assign  
to the QSC-100. Most computers have BIOS setup options to reserve IRQs for either ISA  
or PCI use. Try reserving the IRQ for the ISA card. The BIOS will automatically choose  
a different IRQ for the QSC-100. An address conflict is unlikely because most PCI-based  
computers will assign I/O addresses in such a way that they cannot conflict withISA-bus  
devices.  
3. The QSC-100 may be defective. Contact technical support for instructions.  
Cannot communicate with other equipment.  
1. Are the cable connections correct? Are the cables securely attached?  
2. Is the software configured with the correct base address and IRQ information for the  
QSC-100? (This is mainly a DOS issue.)  
3. Is the device driver installed?  
4. If you are trying to communicate with another DTE, a null-modem cable will be required.  
5. If possible, use a loopback connector to test the port. This connector needs to connect the  
following sets of signals on a D-25 connector:  
TxD and RxD (pins 2 and 3)  
RTS and CTS (pins 4 and 5)  
DCD, DTR, DSR, and RI (pins 8, 20, 6 and 22)  
Quatech QSC-100 User's Manual  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
QSC-100  
User's Manual  
Revision 1.11  
March 2004  
P/N: 940-0146-111  
Quatech QSC-100 User's Manual  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Radio Shack Pager 17 8022 User Guide
RCA Flat Panel Television RLED1530 User Guide
RCA Speaker 40 5019 User Guide
Roland Electronic Keyboard FXWS04 User Guide
RTS Network Card XCP 48 RJ45 User Guide
Ryobi Pole Saw RY43160 User Guide
Samsung Projection Television 713V User Guide
Sanus Systems Indoor Furnishings EF20 User Guide
Sanyo DVR dsr 2004 User Guide
Schneider Electric Network Card AP9635 User Guide