AIR COOLED WATER CHILLERS AND HEAT PUMPS WITH AXIAL FANS
06617645-02
TEV LTD, ARMYTAGE ROAD, BRIGHOUSE, WEST YORKSHIRE, HD6 1QF. TEL: + 44 (0) 1484 405630 FAX: +44 (0) 1484 405620
Download from Www.Somanuals.com. All Manuals Search And Download.
EC DECLARATION OF CONFORMITY
Herewith TEV Ltd declare that the air conditioning equipment designated below is in accordance with the essential
requirements of current EC Directives.
This declaration is based on the design and construction of the equipment in the form brought onto the market by TEV Ltd.
If alterations are made to the machinery without prior consultation with TEV Ltd. this declaration becomes invalid.
Relevant EC Council Directives:
Machinery Directive (98/37/EC)
EMC Directive (89/336/EEC in the versions 93/68/EEC)
Low Voltage Directive (73/23/EEC in the version 93/68/EEC)
Directive PED (97/23/EC)
Applied harmonised standards:
Basis of self attestation:
EN 292-1:1991, EN 292-2:1991, EN 294:1992, EN 349:1993, EN 55014-1:2000,
EN 55014-2:1997, EN 60335-1:2002, EN 60335-2-40:2003, EN 61000-3:1995
BS EN ISO 9001:2000
BSI registered firm certificate no. FM671
EG KONFORMITÄTSERKLÄRUNG
Hiermit erklärt TEV Ltd, daß die unten angegebenen Klimageräte in Übereinstimmung mit den Gesundheits - und
Sicherheitsbestimmungen der gültigen EG-Direktiven stehen.
Diese Erklärung bezieht sich auf die Konzeption und die Konstruktion der Geräte, die von TEV Ltd. auf den Markt gebracht
werden.
Wenn Veränderungen an den Geräten ohne vorherige Absprache mit TEV Ltd. gemacht werden, so wird diese Erklärung
ungültig.
Relevante EG Richtlinien:
Maschinen - Richtlinien (Version 98/37/EWG)
EMV Direktive: (89/336/EWG/EEC in den Versionen 93/68/EWG)
Niederspannungsrichtlinie: (73/23/EWG/EEC in der Version 93/68/EWG)
Richtlinien PED (97/23/EC)
Angewandte Standard
Normen:
EN 292-1:1991, EN 292-2:1991, EN 294:1992, EN 349:1993, EN 55014-1:2000,
EN 55014-2:1997, EN 60335-1:2002, EN 60335-2-40:2003, EN 61000-3:1995
Bestätigungsgrundlage:
BS EN ISO 9001:2000
Zertifikat Nr. FM 671
Model Name:
Nom du modèle:
Nombre del Modelo:
Machinebeschrijving:
Modellname:
Serial Number:
Numéro de série:
Numéro de Serie:
Serienummer:
Serienummer:
Model Part Number:
Référence du modèle:
Artikelnummer:
Modellnummer:
Número de la Parte del Modelo:
Signature of TEV Ltd. designated Handtekening van de gemachtigde
"responsible person":
persoon bij TEV Ltd.:
Unterschrift von TEV Ltd.
"verantwortliche Person":
Signature d' TEV Ltd Le responsable:
Firma de TEV Ltd. designado como
"persona responsable":
(A C HAMMERSLEY)
Position of Signatory:
Fonction du signataire:
Cargo del firmante:
Functie van gemachtigde
Position desUnterschreibenden:
MANUFACTURING DIRECTOR
DIRECTEUR DE FABRICATION
DIRECTOR FABRICACIÓN
PRODUKTIE COÖRDINATOR
PRODUKTIONS DIREKTOR
06617645-02
3
Download from Www.Somanuals.com. All Manuals Search And Download.
TECHNICAL FEATURES
Frame
All QLAC unit enclosures are manufactured from hot-galvanised sheet steel, painted with polyurethane
powder enamel and stoved at 180°C to provide a durable, corrosion resistant finish. The frame is self-
supporting with removable panels. All screws and rivets are made from stainless steel. The paint colour is
RAL 7035.
Refrigerant circuit
Refrigerant is R407C. The refrigerant circuit is assembled using quality brand components and in
accordance with ISO 97/23 concerning welding procedures. Model sizes 140 and upwards have multiple
refrigerant circuits. Each refrigerant circuit is totally independent of the other. Failure of one circuit does not
influence the other circuit. The refrigerant circuit includes:
Liquid line manual shut-off valve
Sight glass
Filter drier
Thermal expansion valve with external equalizer
Electronic expansion valve with control to optimise efficiency in part load conditions (option)
Reversing valve (heat pump version only)
Non return valve (for heat pump version only)
Liquid receiver (for heat pump version only)
Schraeder valves for maintenance and control
Pressure safety device (according to PED requirements)
Compressors
Scroll compressors are used, each fitted with a crankcase heater and provided with thermal overload
protection via a klixon embedded in the motor winding. Compressors are mounted in a separate chamber in
order to be separated from the air stream and to enable maintenance to be performed whilst the unit is still
operating. The crankcase heater is always powered when the compressors are in stand-by. All compressors
are in tandem configuration. This creates higher efficiencies uring part load conditions compared to units
with independant refrigeration circuits per compressor.
Condensers
Condensers are made of copper tubes and aluminium fins. The diameter of the copper tubes is 3/8” and the
thickness of the aluminium fins is 0.1 mm. Tubes are mechanically expanded into the aluminium fins to
maximise heat transfer. The geometry of these condensers guarantees a low air side pressure drop and
allows the use of slow running (and low noise) fans. The condensers can be protected by a metallic filter
(option).
Fans
Fans are axial type with aerofoil blades. They are statically and dynamically balanced and supplied complete
with safety fan guard that complies with the requirements of EN 294. They are mounted on the unit frame
using rubber anti-vibration mounts. The electric motors are 6 pole (approx. 900 rpm) in the low noise version
and 8 pole (approx. 750 rpm) in the extra low noise version. The fans are directly driven and are fitted with
integral overload protection. Motors have moisture protection to IP 54.
06617645-02
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Evaporators
The plate evaporators are made of 316 stainless steel, braze-welded. Unit sizes 040 to size 130 have a
single water side circuit. From unit size 140 upwards, the circuits are double “cross flow” type. The use of
these types of evaporator allows a significant reduction of the refrigerant charge for the unit compared to
traditional shell-in-tube evaporators and increases the efficiency of the refrigerant cycle during part load
operation. The evaporators are factory insulated with flexible close-cell insulation and can be fitted with an
antifreeze heater (optional). Each evaporator is provided with a temperature sensor as antifreeze protection.
Hydraulic circuit (K versions only)
QLAC chillers can be supplied with an optional built in hydraulic kit that includes:
Water tank: various capacities (depending on the size of the unit), factory insulated with flexible close-cell
material and ready for installation of an antifreeze kit (option). The water tank is installed on the supplied
water side (7°C) in order to minimize fluctuations in the water temperature caused by cycling of the
compressors. By installing on the supply side, the supply water temperature can be maintained for some
time after the compressors turn off, a situation that cannot be achieved if the water tank is installed on the
return water side (12°C).
Water pump: centrifugal type, is available in single (K1) or double configuration (K2). In the K2 version, one
pump is running and one pump is in stand-by. The change over can be manual (by a manual switch installed
in the electric box) or automatically controlled by the microprocessor (option). The expansion vessel, safety
valve and manual valves with fittings are sited in the hydraulic circuit.
Electrics enclosure
Access to the electrics enclosure is achieved by switching the mains isolator to "OFF" and removing the
front cover.The electrics conform to electromagnetic compatibility norms CEE 73/23 and 89/336. Moisture
protection is IP55.
All QLAC units have installed, as standard, a compressor sequence relay, which disables compressor
operation if the power supply phase sequence is incorrect (scroll compressors can be damaged if they
operate in reverse). The following components are also installed as standard:
Mains switch,
Compressor fuses
Compressor contactors
Magnetic-thermal switches (MCB's) for protection of pumps and fans
Control circuit automatic breakers
Fan contactors, pump contactors.
The terminal board is supplied with volt free contacts for remote ON-OFF, Heat / Cool change over (heat
pumps only) and general alarms.
Microprocessors
QLAC units are supplied with microprocessor controls as standard. The specific controller used depends
upon the unit size, number of features and use of optional features e.g. electronic expansion valves.The
microprocessor controls the following basic functions:
regulation of the water temperature
antifreeze protection
compressor timing
compressor automatic starting sequence
alarm reset
volt free contact for remote common alarm
alarms and leds.
Any microprocessor can, on request, be connected to a BMS system for remote control and management.
Typically, solutions can be found for MODBUS, LONWORKS, BACNET or TREND protocols.
Control and protection devices
All units are supplied with the following control and protection devices:
Return water temperature sensor, installed on the return water line from the plant (12°C)
Antifreeze protection sensor installed on the outlet water temperature (7°C)
High pressure switch with manual reset
Low pressure switch with automatic reset
High pressure safety valve
Compressor thermal overload protection
Fan thermal overload protection
Flow switch. (std versions supplied loose, K versions factory fitted)
06617645-02
5
Download from Www.Somanuals.com. All Manuals Search And Download.
OTHER VERSIONS
The following versions all incorporate energy efficiency features that make a valuable contribution to
enabling compliance with the European Energy Performance of Buildings Directive and the 2006
amendments to Part L of the UK Building Regulations.
Heat pump version (HP)
Heat pump versions are provided with a 4-way reversing valve and can produce hot water up to 45-50°C.
They are always supplied with a second thermostatic valve and a liquid receiver to optimise the efficiency of
the refrigerant cycle in heating and in cooling. The microprocessor is set for automatic defrost (for operation
in severe ambient conditions) and for Heat/Cool change over by digital input.
Free cooling version (FC)
The Free Cooling option is a system designed to give important energy savings, when the cooling system is
operating continuously and when ambients are low. Free cooling units use low temperature ambient air to
cool down the water in the system. In some situations, chilled water can be produced without any
mechanical refrigeration (compressors) with consequent large reduction of power consumption. The Free
Cooling system comprises:
Free cooling coil:
Heat exchanger made of copper tubes and aluminium fins, with bleed
valves.
Microprocessor control:
3 way valve:
The “heart” of the system; it allows correct control of all parameters, leading
to high efficiencies over a range of ambient conditions.
An ON/OFF 3 way valve that opens/closes the free cooling circuit,
depending on the signal coming from the microprocessor control.
Head pressure control:
Maintains the correct condensing pressure in the refrigerant circuit when
ambient temperatures are low. In Free Cooling systems, this effect is
achieved by partially closing refrigerant circuits in the condensing coil with
solenoid valves: this reduces the heat transfer capacity and maintains a
suitable condensing pressure.
Heat Recovery Version
A version that includes heat recovery by the addition of a de-superheater heat exchanger located between
the compressor and condenser, is also available. This de-superheater can be fitted to both chiller and heat
pump versions, however, in the heat pump it must be used only when in cooling mode. In heating mode the
water circuit must be isolated. The de-superheater is capable of generating 50°C hot water for domestic use
(washing etc) and can recover up to 25% of the energy removed in cooling by this manner. Such units make
a valuable contribution to energy efficiency.
06617645-02
6
Download from Www.Somanuals.com. All Manuals Search And Download.
WATER CHILLERS AND HEAT PUMPS
QLAC / LS (Low noise version)
TECHNICAL DATA
MOD.
040
045
050
060
070
080
090
110
Refrigerant
R407C R407C R407C R407C R407C R407C R407C R407C
Cooling capacity
kW
kW
l/h
37
45,0
15,1
7910
32,4
52,0
17,2
58,0
19,3
64,0
21,5
78,0
25,8
90,0
29,9
104,0
33,9
Compressor input power
Water flow rate
12,6
6490
26,2
9290 10320 11520 13590 15650 18400
Water pressure drop
KPa
31,5
23,3
30,1
30,4
27,6
26,5
Heating capacity
kW
kW
l/h
38,5
12,9
6630
28,5
47,0
15,2
8085
33,8
55,0
17,3
62,0
19,5
68,0
21,7
83,0
26,4
95,0
30,3
107,0
34,2
Compressor input power
Water flow rate
9460 10665 11695 14275 16340 18400
Water pressure drop
kPa
32,6
24,8
31,0
33,5
30,0
26,5
Total input current (K version)
Total peak current
A
32,4
36
37,4
40,1
42,8
52,6
62,0
67,5
A
A
121,4 148,4 154,4 194,4 194,0 235,4 265,1 275,1
39,4 45,4 49,4 54,4 59,4 69,4 81,1 91,1
400/3/50
Maximum input current
Power suppy
V/Ph/Hz
Airflow
Fans
m³/h 10800 10800 18800 18800 18000 17280 28080 27000
n° x kW 2 x 0,37 2 x 0,37 2 x 0,69 2 x 0,69 2 x 0,69 2 x 0,69 3 x 0,69 3 x 0,69
type
n°
Scroll
Compressors
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
Refrigerant circuits
Control steps
n°
n°
Sound power level (1)
Sound pressure level (2)
dB(A)
dB(A)
77
49
77
49
79
51
79
51
80
52
80
52
82
54
82,5
54,5
Water pump (option)
kW
1,1
2,9
165
180
18
1,1
2,9
160
180
18
1,1
2,9
141
300
18
1,1
2,9
1,1
2,9
110
300
18
1,5
4,3
150
300
18
1,5
4,3
130
530
18
2,2
5,3
150
530
18
Water pump input current
Pump available pressure (option)
Water tank capacity (option)
Expansion vessel (option)
A
kPa
125
300
18
l
l
Length
mm
mm
mm
kg
1870
850
1870
850
2608
1105
1759
710
2608
1105
1759
725
2608
1105
1759
760
2608
1105
1759
810
3608
1105
1759
1070
1280
3608
1105
1759
1150
1360
Width
Height
1406
570
1406
590
Weight (Standard configuration)
Weight (with hydraulic kit)
kg
730
750
880
895
930
980
Performances are rated at:
Cooling: ambient air temperature 35 °C; evaporator water temperature in/out 12°C / 7 °C.
Heating: ambient air temperature 8.3 °C db, 6.1 °C wb ; condenser water temperature in/out 40°C / 45 °C.
(1): Sound power level according to ISO 3746.
(2): Sound pressure level measured at 10m from the unit in free field conditions: direction factor Q=2 (according to ISO 3746).
06617645-02
7
Download from Www.Somanuals.com. All Manuals Search And Download.
WATER CHILLERS AND HEAT PUMPS
QLAC / LS (Low noise version)
TECHNICAL DATA
MOD.
120
130
140
160
190
210
240
260
Refrigerant
R407C R407C R407C R407C R407C R407C R407C R407C
Cooling capacity
kW
kW
l/h
115,5
38
128
142
156
181
206,1
67,8
232
76
256
Compressor input power
Water flow rate
42,1
47,3
51,7
59,7
84,2
20640 22190 24600 27180 31990 36290 41450 45240
Water pressure drop
kPa
29,4
30,0
30,8
36,0
39,6
42,7
49,0
51,2
Heating capacity
kW
kW
l/h
120
132
150
165
189
217
242
267
Compressor input power
Water flow rate
38,5
42,9
48,1
52,8
60,6
68,4
77,1
85,8
20640 22700 25800 28380 32510 37320 41620 45920
Water pressure drop
kPa
29,4
76,4
31,3
85,5
33,8
39,2
40,9
45,1
49,4
52,7
Total input current (K version)
Total peak current
A
96,3
290
104,7 126,6 144,0 160,2 178,4
304 351 369 431 453
A
A
322,1 333,1
Maximum input current
Power supply
102,1 113,1 119,9 138,3 167,6 185,6 211,6 233,6
400/3/50
V/Ph/Hz
Airflow
Fans
m°/h 25920 25920 36000 34920 55800 55800 58800 58800
n° x kW 3 x 0,69 3 x 0,69 4 x 0,69 4 x 0,69 3 x 2,0 3 x 2,0 4 x 2,0 4 x 2,0
type
n°
Scroll
Compressors
2
1
2
2
1
2
4
2
4
4
2
4
4
2
4
4
2
4
4
2
4
4
2
4
Refrigerant circuits
Control steps
n°
n°
Sound power level (1)
Sound pressure level (2)
dB(A)
dB(A)
82,9
54,9
83,1
55,1
83,5
55,5
84
56
86
58
86
58
89
61
89
61
Water pump (option)
kW
2,2
5,3
120
530
18
2,2
5,3
130
530
18
2,2
5,3
105
530
18
3,0
8,5
3,0
8,5
140
670
18
3,0
8,5
110
670
18
4,0
9,9
170
670
18
4,0
9,9
155
670
18
Water pump input current
Pump available pressure (option)
Water tank capacity (option)
Expansion vessel (option)
A
kPa
180
670
18
l
l
mm
mm
mm
kg
3608
1105
1759
1200
1410
3608
1105
1759
1230
1440
4108
1105
2179
1650
1860
4108
1105
2179
1700
2000
4708
1105
2262
1960
2260
4708
1105
2262
2050
2350
4708
1105
2262
2160
2460
4708
1105
2262
2480
2780
Length
Width
Height
Weight (Standard configuration)
Weight (with hydraulic kit)
kg
Performances are rated at:
Cooling: ambient air temperature 35 °C; evaporator water temperature in/out 12°C / 7 °C.
Heating: ambient air temperature 8.3 °C db, 6.1 °C wb ; condenser water temperature in/out 40°C / 45 °C.
(1): Sound power level according to ISO 3746.
(2): Sound pressure level measured at 10m from the unit in free field conditions: direction factor Q=2 (according to ISO 3746).
06617645-02
8
Download from Www.Somanuals.com. All Manuals Search And Download.
WATER CHILLERS AND HEAT PUMPS
QLAC / LS (Low noise version)
TECHNICAL DATA
MOD.
300
320
380
430
500
Refrigerant
R407C R407C R407C R407C R407C
Cooling capacity
kW
kW
l/h
290
321
383
432
481
Compressor input power
Water flow rate
92,4
100,6 126,4 138,7 150,9
49880 55200 65800 74300 82700
Water pressure drop
kPa
34
39
32
38
44
Free cooling capacity
input power
kW
kW
l/h
185
12
185
12
235
16
245
16
240
16
Water flow rate
49880 55200 65800 74300 82700
Water pressure drop
kPa
107
121
113
121
141
Total input current (K version)
Total peak current
A
201,4
510
220
534
279,2 301,7 324,2
A
A
582
641
672,5
425
Maximum input current
Power supply
262,6 287,2
362
393,5
V/Ph/Hz
400/3/50
Airflow
Fans
m°/h 89000 88500 119000 118000 118000
n° x kW 6x2
6x2
8x2
8x2
8x2
type
Scroll
Compressors
n°
n°
n°
4
2
4
4
2
4
6
2
6
6
2
6
6
2
6
Refrigerant circuits
Control steps
Sound power level (1)
Sound pressure level (2)
dB(A)
dB(A)
90
62
90
62
91
63
91
63
91
63
Water pump (option)
kW
4
5,5
172
670
25
7,5
210
670
50
7,5
190
670
50
7,5
160
670
50
Pump available pressure (option)
Water tank capacity (option)
Expansion vessel (option)
kPa
160
670
25
l
l
mm
mm
mm
kg
4108
2201
2262
2750
3150
4108
2201
2262
2800
3220
4708
2201
2262
3100
3550
4708
2201
2262
3150
3610
4708
2201
2262
3210
3690
Length
Width
Height
Weight (Standard configuration)
Weight (with hydraulic kit)
kg
Performances are rated at:
Cooling: ambient air temperature 35 °C; evaporator water temperature in/out 12°C / 7 °C.
Free cooling: ambient air temperature 2 °C; water inlet temperature 15°C, glycol 20%, nominal waterflow, compressors switched off
(1): Sound power level according to ISO 3746.
(2): Sound pressure level measured at 10m from the unit in free field conditions: direction factor Q=2 (according to ISO 3746).
06617645-02
9
Download from Www.Somanuals.com. All Manuals Search And Download.
WATER CHILLERS AND HEAT PUMPS
QLAC / XL (Extra Low noise version)
TECHNICAL DATA
MOD.
040
045
050
060
070
080
090
110
Refrigerant
R407C R407C R407C R407C R407C R407C
Cooling capacity
kW
kW
l/h
52
58
64
78
90
104
### ###
Compressor input power
Water flow rate
17,2
19,3
21,5
25,8
29,9
33,9
9290 10320 11520 13590 15650 18400
Water pressure drop
KPa
31,5
23,3
30,1
30,4
27,6
26,5
Heating capacity
kW
kW
l/h
55,0
17,3
62,0
19,5
68,0
21,7
83,0
26,4
95,0
30,3
107,0
34,2
Compressor input power
Water flow rate
9460 10665 11695 14275 16340 18400
Water pressure drop
kPa
32,6
24,8
31,0
33,5
30,0
26,5
Total input current (K version)
Total peak current
A
37,4
40,1
42,8
194
52,6
62
67,5
A
A
154,4 194,4
49,4 54,4
235,4 265,1 275,1
69,4 81,1 91,1
Maximum input current
Power suppy
59,4
V/Ph/Hz
400/3/50
Airflow
Fans
m³/h
24000 24000 24000 23600 35000 35000
2 x 1.23 2 x 1.23 2 x 1.23 2 x 1.23 3 x 1.23 3 x 1.23
n° x kW
type
n°
Scroll
Compressors
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
Refrigerant circuits
Control steps
n°
n°
Sound power level (1)
Sound pressure level (2)
dB(A)
dB(A)
76
48
76
48
78
50
78
50
79,5
51,5
79,9
51,9
Water pump (option)
kW
1,1
141
300
18
1,1
125
300
18
1,1
110
300
18
1,5
150
300
18
1,5
130
530
18
2,2
150
530
18
Pump available pressure (option)
Water tank capacity (option)
Expansion vessel (option)
kPa
l
l
Length
mm
mm
mm
kg
2608
1105
1842
710
2608
1105
1842
725
2608
1105
1842
760
2608
1105
1842
810
3608
1105
1842
1070
1280
3608
1105
1842
1150
1360
Width
Height
Weight (Standard configuration)
Weight (with hydraulic kit)
kg
880
895
930
980
# # # XL Models in these sizes are available as a special unit. Contact QUARTZ technical department for details.
Performances are rated at:
Cooling: ambient air temperature 35 °C; evaporator water temperature in/out 12°C / 7 °C.
Heating: ambient air temperature 8.3 °C db, 6.1 °C wb ; condenser water temperature in/out 40°C / 45 °C.
(1): Sound power level according to ISO 3746.
(2): Sound pressure level measured at 10m from the unit in free field conditions: direction factor Q=2 (according to ISO 3746).
06617645-02
10
Download from Www.Somanuals.com. All Manuals Search And Download.
WATER CHILLERS AND HEAT PUMPS
QLAC / XL (Extra Low noise version)
TECHNICAL DATA
MOD.
120
130
140
160
190
210
240
260
Refrigerant
R407C R407C R407C R407C R407C R407C
Cooling capacity
kW
kW
l/h
115,5
38
128
142
156
181
206,1
67,8
### ###
Compressor input power
Water flow rate
42,1
47,3
51,7
59,7
20640 22190 24600 27180 31990 36290
Water pressure drop
kPa
29,4
30,0
30,8
36,0
39,6
42,7
Heating capacity
kW
kW
l/h
120
132
150
165
189
217
Compressor input power
Water flow rate
38,5
42,9
48,1
52,8
60,6
68,4
20640 22700 25800 28380 32510 37320
Water pressure drop
kPa
29,4
76,4
31,3
85,5
33,8
39,2
40,9
45,1
Total input current (K version)
Total peak current
A
96,3
290
104,7 126,6
304 351
144
369
A
A
322,1 333,1
Maximum input current
Power supply
102,1 113,1 119,9 138,3 167,6 185,6
400/3/50
V/Ph/Hz
Airflow
Fans
m°/h 33000 33000 33000 33000 64000 62000
n° x kW 3 x 1.23 3 x 1.23 3 x 1.23 3 x 1.23 4 x 1,25 4 x 1,25
type
n°
Scroll
Compressors
2
1
2
2
1
2
4
2
4
4
2
4
4
2
4
4
2
4
Refrigerant circuits
Control steps
n°
n°
Sound power level (1)
Sound pressure level (2)
dB(A)
dB(A)
80,1
52,1
80,5
52,5
81
53
81,3
53,3
84
58
84
58
Water pump (option)
kW
2,2
120
530
18
2,2
130
530
18
2,2
105
530
18
3,0
180
670
18
3,0
140
670
18
3,0
110
670
18
Pump available pressure (option)
Water tank capacity (option)
Expansion vessel (option)
kPa
l
l
mm
mm
mm
kg
3608
1105
1842
1200
1410
3608
1105
1842
1230
1440
4108
1105
2262
1650
1860
4108
1105
2262
1700
2000
4708
1105
2262
1960
2260
4708
1105
2262
2050
2350
Length
Width
Height
Weight (Standard configuration)
Weight (with hydraulic kit)
kg
# # # XL Models in these sizes are available as a special unit. Contact QUARTZ technical department for details.
Performances are rated at:
Cooling: ambient air temperature 35 °C; evaporator water temperature in/out 12°C / 7 °C.
Heating: ambient air temperature 8.3 °C db, 6.1 °C wb ; condenser water temperature in/out 40°C / 45 °C.
(1): Sound power level according to ISO 3746.
(2): Sound pressure level measured at 10m from the unit in free field conditions: direction factor Q=2 (according to ISO 3746).
06617645-02
11
Download from Www.Somanuals.com. All Manuals Search And Download.
QLAC / LS (LOW NOISE VERSION)
COOLING CAPACITIES AND COMPRESSOR INPUT POWER
PF (kW)
TA (°C)
PA (kW)
TA (°C)
30 35
MOD.
TU (°C)
20
25
30
35
40
---
---
---
---
45
---
---
---
---
---
---
20
25
40
---
---
---
---
45
---
---
---
---
---
---
-5
-3
-1
1
26,64 24,98 23,36 21,79
29,27 27,48 25,74 24,04
32,07 30,15 28,28 26,44
35,05 33,00 30,98 29,00
9,39
9,36
9,32
9,28
9,24
9,21
9,19
9,19
9,21
9,26
9,34
10,50 11,71 13,02
10,50 11,76 13,13
10,48 11,77 13,21
10,44 11,77 13,25
3
38,23 36,02 33,85 31,73 29,65
41,60 39,24 36,91 34,63 32,39
10,41 11,75 13,27 14,94
10,36 11,72 13,26 14,98
5
040
7
45,18 42,66 40,17 37,71 35,31 32,95
48,97 46,28 43,62 40,99 38,41 35,87
52,99 50,12 47,28 44,48 41,71 38,98
57,24 54,19 51,16 48,17 45,21 42,29
61,74 58,50 55,27 52,08 48,92 45,80
10,33 11,68 13,24 15,00 16,93
10,30 11,64 13,21 14,99 16,97
10,28 11,60 13,17 14,97 16,98
10,28 11,57 13,13 14,93 16,97
10,30 11,56 13,09 14,90 16,95
9
11
13
15
-5
-3
-1
1
33,41 31,45 29,48 27,48
36,45 34,36 32,24 30,11
39,69 37,45 35,19 32,90
43,13 40,75 38,33 35,89
---
---
---
---
---
---
---
---
---
---
11,23 12,52 13,96 15,56
11,22 12,53 13,99 15,60
11,21 12,53 14,01 15,64
11,19 12,53 14,02 15,67
---
---
---
---
---
---
---
---
---
---
3
46,80 44,25 41,67 39,06 36,42
50,69 47,98 45,23 42,44 39,63
11,18 12,52 14,02 15,69 17,54
11,16 12,51 14,03 15,71 17,58
5
045
050
060
7
54,83 51,94 49,01 46,00 43,04 40,00 11,14 12,50 14,02 15,72 17,61 19,70
59,21 56,14 53,02 49,86 46,66 43,43 11,12 12,48 14,02 15,73 17,63 19,74
63,85 60,59 57,27 53,91 50,51 47,07 11,09 12,47 14,01 15,73 17,65 19,78
68,77 65,30 61,78 58,21 54,60 50,95 11,07 12,45 14,00 15,73 17,66 19,80
73,96 70,28 66,55 62,77 58,94 55,06 11,05 12,43 13,98 15,73 17,67 19,83
9
11
13
15
-5
-3
-1
1
39,58 37,29 34,94 32,53
43,08 40,64 38,14 35,57
46,80 44,21 41,54 38,82
50,76 48,00 45,17 42,27
---
---
---
---
---
---
---
---
---
---
12,52 13,96 15,50 17,15
12,50 13,98 15,58 17,30
12,47 13,98 15,63 17,41
12,43 13,97 15,66 17,49
---
---
---
---
---
---
---
---
---
---
3
54,98 52,04 49,03 45,95 42,79
59,45 56,33 53,13 49,86 46,50
12,38 13,94 15,66 17,54 19,58
12,34 13,90 15,64 17,57 19,66
5
7
64,19 60,88 57,49 54,00 50,46 46,82 12,29 13,85 15,62 17,57 19,71 22,03
69,22 65,71 62,12 58,43 54,66 50,80 12,25 13,81 15,58 17,56 19,74 22,11
74,55 70,83 67,02 63,11 59,12 55,04 12,22 13,77 15,54 17,53 19,74 22,17
80,19 76,25 72,21 68,08 63,85 59,53 12,21 13,73 15,50 17,50 19,74 22,20
86,14 81,97 77,70 73,34 68,87 64,31 12,22 13,70 15,46 17,46 19,71 22,21
9
11
13
15
-5
-3
-1
1
44,18 41,55 38,86 36,12
48,09 45,29 42,42 39,49
52,26 49,27 46,22 43,09
56,69 53,51 50,26 46,93
---
---
---
---
---
---
---
---
---
---
14,46 16,14 17,97 19,95
14,47 16,18 18,07 20,12
14,46 16,20 18,13 20,25
14,45 16,21 18,18 20,35
---
---
---
---
---
---
---
---
---
---
3
61,41 58,02 54,56 51,02 47,40
66,42 62,82 59,14 55,37 51,52
14,43 16,21 18,21 20,42 22,85
14,42 16,20 18,22 20,47 22,95
5
7
71,73 67,91 64,00 60,00 55,91 51,74 14,40 16,18 18,21 20,49 23,02 25,78
77,37 73,31 69,16 64,91 60,58 56,15 14,40 16,17 18,21 20,51 23,07 25,88
83,34 79,04 74,63 70,13 65,54 60,85 14,41 16,16 18,20 20,51 23,10 25,96
89,66 85,10 80,43 75,67 70,80 65,84 14,44 16,17 18,19 20,50 23,11 26,01
96,34 91,51 86,57 81,53 76,39 71,14 14,50 16,19 18,19 20,50 23,12 26,04
9
11
13
15
TU: Outlet water temperature (°C)
TA: Ambient temperature (°C)
PA: Compressors input power (kW)
PF: Cooling capacity (kW)
06617645-02
12
Download from Www.Somanuals.com. All Manuals Search And Download.
QLAC / LS (LOW NOISE VERSION)
COOLING CAPACITIES AND COMPRESSOR INPUT POWER
PF (kW)
TA (°C)
PA (kW)
TA (°C)
30 35
MOD.
TU (°C)
20
25
30
35
40
---
---
---
---
45
---
---
---
---
---
---
20
25
40
---
---
---
---
45
---
---
---
---
---
---
-5
-3
-1
1
49,33 46,44 43,48 40,47
53,68 50,59 47,43 44,21
58,31 55,01 51,64 48,21
63,23 59,72 56,13 52,47
15,63 17,47 19,51 21,77
15,65 17,51 19,60 21,92
15,66 17,54 19,66 22,03
15,66 17,56 19,71 22,12
3
68,47 64,73 60,91 57,00 53,02
74,04 70,06 65,99 61,83 57,59
15,67 17,57 19,74 22,18 24,90
15,69 17,58 19,76 22,23 24,99
5
070
7
79,95 75,72 71,39 67,00 62,46 57,87 15,72 17,59 19,77 22,26 25,05 28,15
86,21 81,72 77,12 72,43 67,64 62,76 15,76 17,62 19,79 22,28 25,10 28,24
92,85 88,08 83,20 78,22 73,14 67,97 15,83 17,65 19,81 22,30 25,14 28,31
99,87 94,81 89,64 84,37 78,99 73,50 15,92 17,70 19,84 22,32 25,16 28,36
107,3 101,9 96,46 90,88 85,18 79,38 16,05 17,78 19,88 22,35 25,19 28,40
9
11
13
15
-5
-3
-1
1
58,51 55,07 51,54 47,94
63,71 60,03 56,27 52,42
69,24 65,32 61,31 57,21
75,12 70,95 66,68 62,30
---
---
---
---
---
---
---
---
---
---
19,61 21,99 24,54 27,22
19,57 22,02 24,67 27,51
19,52 22,00 24,75 27,71
19,46 21,96 24,76 27,83
---
---
---
---
---
---
---
---
---
---
3
81,38 76,94 72,39 67,73 62,97
88,03 83,30 78,46 73,50 68,44
19,40 21,90 24,75 27,89 31,30
19,37 21,84 24,70 27,90 31,42
5
080
090
110
7
95,08 90,06 84,91 79,00 74,26 68,76 19,37 21,79 24,64 27,88 31,47 35,37
102,5 97,22 91,75 86,16 80,45 74,61 19,41 21,76 24,58 27,83 31,47 35,47
110,5 104,8 99,02 93,08 87,02 80,84 19,52 21,77 24,54 27,77 31,45 35,51
118,8 112,8 106,7 100,4 94,00 87,45 19,70 21,83 24,52 27,72 31,40 35,51
127,7 121,3 114,8 108,2 101,4 94,47 19,97 21,96 24,54 27,68 31,34 35,48
9
11
13
15
-5
-3
-1
1
67,32 63,10 58,71 54,16
73,37 68,89 64,23 59,41
79,80 75,05 70,12 65,01
86,64 81,61 76,39 70,98
---
---
---
---
---
---
---
---
---
---
22,38 25,09 28,16 31,62
22,41 25,14 28,23 31,73
22,44 25,18 28,30 31,83
22,46 25,21 28,34 31,90
---
---
---
---
---
---
---
---
---
---
3
93,92 88,59 83,06 77,33 71,41
101,6 96,00 90,15 84,10 77,84
22,50 25,24 28,39 31,97 36,01
22,54 25,27 28,43 32,02 36,09
5
7
109,8 103,8 97,69 91,00 84,68 77,87 22,59 25,31 28,46 32,07 36,15 40,75
118,5 112,2 105,6 98,92 91,95 84,76 22,66 25,37 28,51 32,11 36,21 40,84
127,6 121,0 114,1 107,0 99,67 92,10 22,75 25,43 28,56 32,16 36,27 40,91
137,4 130,3 123,1 115,6 107,8 99,88 22,86 25,51 28,62 32,21 36,32 40,97
147,6 140,2 132,6 124,7 116,5 108,1 23,00 25,61 28,70 32,28 36,38 41,04
9
11
13
15
-5
-3
-1
1
78,60 73,67 68,49 63,05
85,65 80,44 74,96 69,23
93,15 87,65 81,87 75,82
101,1 95,32 89,22 82,84
---
---
---
---
---
---
---
---
---
---
24,07 26,92 30,28 34,24
24,17 27,00 30,31 34,21
24,28 27,10 30,38 34,23
24,39 27,21 30,47 34,28
---
---
---
---
---
---
---
---
---
---
3
109,5 103,4 97,04 90,32 83,31
118,5 112,1 105,3 98,27 90,89
24,50 27,33 30,59 34,36 38,76
24,61 27,46 30,71 34,47 38,83
5
7
128,1 121,3 114,1 107,0 98,96 90,90 24,69 27,58 30,85 34,60 38,92 43,93
138,1 131,0 123,5 115,6 107,5 99,06 24,76 27,70 30,99 34,74 39,05 44,01
148,8 141,3 133,4 125,2 116,6 107,7 24,81 27,80 31,13 34,90 39,20 44,13
160,1 152,2 143,9 135,2 126,2 116,9 24,82 27,88 31,26 35,05 39,36 44,28
172,0 163,7 154,9 145,9 136,4 126,6 24,80 27,94 31,38 35,21 39,53 44,44
9
11
13
15
TU: Outlet water temperature (°C)
TA: Ambient temperature (°C)
PA: Compressors input power (kW)
PF: Cooling capacity (kW)
QLAC / LS (LOW NOISE VERSION)
13
06617645-02
Download from Www.Somanuals.com. All Manuals Search And Download.
COOLING CAPACITIES AND COMPRESSOR INPUT POWER
PF (kW)
TA (°C)
PA (kW)
TA (°C)
30 35
MOD.
TU (°C)
20
25
30
35
40
---
---
---
---
45
---
---
---
---
---
---
20
25
40
---
---
---
---
45
---
---
---
---
---
---
-5
-3
-1
1
88,37 82,32 76,09 69,68
96,55 90,15 83,54 76,75
105,2 98,48 91,49 84,29
114,5 107,3 99,94 92,33
27,64 31,00 34,96 39,62
27,75 31,07 34,98 39,56
27,87 31,15 35,02 39,54
28,00 31,26 35,08 39,55
3
124,3 116,7 108,9 100,8 92,62
134,8 126,8 118,5 109,9 101,2
28,14 31,38 35,17 39,58 44,72
28,28 31,51 35,27 39,65 44,73
5
120
7
145,9 137,4 128,6 120,0 110,4 100,9 28,43 31,66 35,39 39,73 44,76 50,57
157,7 148,7 139,4 129,9 120,2 110,2 28,58 31,81 35,53 39,84 44,82 50,57
170,1 160,6 150,9 140,8 130,5 120,0 28,72 31,96 35,67 39,96 44,91 50,60
183,3 173,3 163,0 152,4 141,5 130,4 28,86 32,11 35,83 40,10 45,01 50,66
197,2 186,6 175,8 164,6 153,2 141,5 29,00 32,26 35,98 40,25 45,14 50,75
9
11
13
15
-5
-3
-1
1
95,43 88,46 81,36 74,17
104,5 97,10 89,57 81,92
114,1 106,3 98,31 90,19
124,4 116,1 107,6 99,00
---
---
---
---
---
---
---
---
---
---
31,38 35,29 39,89 45,26
31,48 35,34 39,88 45,17
31,61 35,41 39,88 45,11
31,74 35,50 39,92 45,08
---
---
---
---
---
---
---
---
---
---
3
135,4 126,5 117,5 108,3 99,10
147,0 137,6 128,0 118,3 108,5
31,90 35,61 39,97 45,06 50,98
32,08 35,73 40,04 45,07 50,91
5
130
140
160
7
159,4 149,4 139,2 129,0 118,5 107,9 32,27 35,88 40,13 45,11 50,88 57,52
172,5 161,9 151,1 140,2 129,2 118,0 32,48 36,05 40,25 45,16 50,87 57,44
186,3 175,1 163,8 152,2 140,5 128,6 32,70 36,23 40,39 45,24 50,88 57,38
201,0 189,2 177,1 164,9 152,5 140,0 32,95 36,44 40,55 45,35 50,92 57,34
216,5 204,0 191,3 178,4 165,3 152,0 33,21 36,66 40,73 45,47 50,98 57,34
9
11
13
15
-5
-3
-1
1
105,5 99,32 92,90 86,35
114,9 108,2 101,4 94,42
124,9 117,7 110,4 103,0
135,5 127,9 120,1 112,1
---
---
---
---
---
---
---
---
---
---
35,77 40,04 44,70 49,71
35,76 40,13 44,94 50,16
35,71 40,15 45,09 50,50
35,66 40,14 45,17 50,72
---
---
---
---
---
---
---
---
---
---
3
146,8 138,7 130,4 121,9 113,2
158,7 150,1 141,3 132,3 123,1
35,62 40,09 45,19 50,86 57,07
35,59 40,04 45,17 50,93 57,29
5
7
171,5 162,3 152,9 143,0 133,5 123,6 35,62 40,01 45,13 50,94 57,42 64,51
185,0 175,2 165,3 155,1 144,7 134,1 35,70 40,00 45,08 50,93 57,48 64,71
199,2 188,9 178,3 167,5 156,5 145,3 35,86 40,03 45,06 50,89 57,50 64,84
214,4 203,4 192,2 180,8 169,1 157,2 36,12 40,14 45,06 50,86 57,48 64,90
230,3 218,7 206,9 194,8 182,4 169,8 36,49 40,32 45,12 50,84 57,46 64,92
9
11
13
15
-5
-3
-1
1
115,9 109,1 102,1 95,01
126,2 118,9 111,5 103,9
137,2 129,4 121,5 113,3
148,9 140,6 132,1 123,4
---
---
---
---
---
---
---
---
---
---
39,22 43,97 49,07 54,44
39,15 44,03 49,35 55,02
39,04 44,00 49,49 55,41
38,91 43,92 49,53 55,66
---
---
---
---
---
---
---
---
---
---
3
161,3 152,4 143,4 134,2 124,8
174,4 165,1 155,5 145,6 135,6
38,80 43,80 49,49 55,78 62,61
38,73 43,68 49,40 55,81 62,83
5
7
188,4 178,4 168,2 158,0 147,1 136,2 38,73 43,58 49,28 55,76 62,93 70,73
203,2 192,6 181,8 170,7 159,4 147,8 38,83 43,53 49,16 55,66 62,95 70,93
218,9 207,7 196,2 184,4 172,4 160,2 39,04 43,55 49,07 55,55 62,89 71,02
235,5 223,6 211,4 199,0 186,3 173,3 39,40 43,66 49,04 55,44 62,79 71,02
253,1 240,5 227,6 214,4 200,9 187,2 39,93 43,91 49,08 55,36 62,69 70,97
9
11
13
15
TU: Outlet water temperature (°C)
TA: Ambient temperature (°C)
PA: Compressors input power (kW)
PF: Cooling capacity (kW)
QLAC / LS (LOW NOISE VERSION)
14
06617645-02
Download from Www.Somanuals.com. All Manuals Search And Download.
COOLING CAPACITIES AND COMPRESSOR INPUT POWER
PF (kW)
TA (°C)
PA (kW)
TA (°C)
30 35
MOD.
TU (°C)
20
25
30
35
40
---
---
---
---
45
---
---
---
---
---
---
20
25
40
---
---
---
---
45
---
---
---
---
---
---
-5
-3
-1
1
3
5
137,1 128,7 120,0 111,0
149,3 140,5 131,2 121,7
162,3 152,9 143,2 133,1
176,2 166,2 155,9 145,2
190,9 180,4 169,4 158,1 146,4
206,5 195,4 183,8 171,8 159,4
223,1 211,3 199,1 186,0 173,3 159,8 43,70 48,91 54,95 61,87 69,75 78,64
240,6 228,2 215,3 201,9 188,1 173,8 43,85 49,02 55,03 61,96 69,86 78,78
259,2 246,1 232,4 218,3 203,8 188,7 44,04 49,16 55,14 62,06 69,96 78,92
278,9 265,0 250,6 235,7 220,4 204,6 44,29 49,34 55,28 62,17 70,07 79,04
299,6 285,0 269,8 254,2 238,0 221,3 44,59 49,56 55,44 62,30 70,18 79,16
156,5 146,1 135,1 123,7
170,6 159,7 148,1 136,1
185,8 174,2 162,0 149,3
201,8 189,6 176,8 163,4
43,27 48,48 54,40 61,08
43,32 48,56 54,53 61,28
43,37 48,63 54,63 61,44
43,43 48,69 54,72 61,58
43,49 48,75 54,80 61,69 69,49
43,58 48,82 54,87 61,79 69,63
190
7
9
11
13
15
-5
-3
-1
1
---
---
---
---
---
---
---
---
---
---
50,88 57,06 64,35 72,97
51,06 57,18 64,37 72,83
51,27 57,35 64,45 72,79
51,51 57,56 64,60 72,83
51,74 57,80 64,80 72,95 82,44
51,98 58,06 65,05 73,13 82,52
---
---
---
---
---
---
---
---
---
---
3
5
218,9 206,0 192,5 178,4 163,7
237,0 223,5 209,2 194,3 178,9
210
240
260
7
9
256,3 241,9 227,0 211,0 195,1 178,2 52,20 58,33 65,32 73,37 82,67 93,43
276,6 261,6 245,8 229,3 212,2 194,5 52,39 58,59 65,61 73,64 82,89 93,55
298,2 282,3 265,7 248,5 230,5 211,9 52,54 58,83 65,90 73,95 83,16 93,74
320,9 304,3 286,8 268,7 249,9 230,4 52,64 59,05 66,20 74,27 83,47 93,99
344,9 327,4 309,2 290,1 270,4 249,9 52,68 59,23 66,47 74,60 83,81 94,30
11
13
15
-5
-3
-1
1
3
5
7
9
11
13
15
-5
-3
-1
1
3
5
7
9
178,3 166,1 153,5 140,6
194,8 181,9 168,5 154,8
212,4 198,7 184,6 170,0
231,1 216,6 201,6 186,3
251,0 235,6 219,8 203,5 186,8
272,1 255,8 239,1 221,9 204,3
---
---
---
---
---
---
---
---
---
---
55,28 62,00 69,93 79,23
55,49 62,13 69,95 79,12
55,73 62,31 70,03 79,08
55,99 62,52 70,16 79,09
56,27 62,76 70,33 79,17 89,44
56,56 63,03 70,55 79,30 89,46
---
---
---
---
---
---
---
---
---
---
294,5 277,3 259,6 241,0 222,8 203,7 56,86 63,31 70,79 79,47 89,53 101,1
318,2 300,1 281,4 262,2 242,5 222,4 57,16 63,61 71,06 79,68 89,65 101,1
343,3 324,2 304,5 284,2 263,4 242,2 57,45 63,92 71,35 79,92 89,82 101,2
369,9 349,7 328,9 307,5 285,6 263,2 57,73 64,22 71,65 80,20 90,03 101,3
398,0 376,7 354,7 332,2 309,2 285,6 57,99 64,53 71,97 80,49 90,28 101,5
194,3 180,1 165,6 151,0
212,7 197,7 182,3 166,8
232,4 216,4 200,1 183,6
253,4 236,4 219,1 201,5
275,7 257,6 239,3 220,6 201,7
299,4 280,2 260,7 241,0 220,9
---
---
---
---
---
---
---
---
---
---
62,76 70,58 79,77 90,51
62,97 70,68 79,75 90,35
63,21 70,82 79,77 90,23
63,49 70,99 79,83 90,16
63,80 71,21 79,93 90,13 101,9
64,15 71,47 80,08 90,15 101,8
---
---
---
---
---
---
---
---
---
---
324,5 304,2 283,6 263,0 241,3 219,8 64,53 71,76 80,27 90,22 101,7 115,0
351,2 329,7 307,8 285,6 263,0 240,2 64,95 72,09 80,50 90,33 101,7 114,8
379,4 356,6 333,5 310,0 286,1 262,0 65,41 72,47 80,78 90,49 101,7 114,7
409,3 385,2 360,7 335,8 310,6 285,1 65,90 72,88 81,09 90,69 101,8 114,6
440,9 415,4 389,5 363,3 336,6 309,6 66,42 73,33 81,45 90,95 101,9 114,6
11
13
15
TU: Outlet water temperature (°C)
TA: Ambient temperature (°C)
PA: Compressors input power (kW)
PF: Cooling capacity (kW)
QLAC / LS (LOW NOISE VERSION)
15
06617645-02
Download from Www.Somanuals.com. All Manuals Search And Download.
COOLING CAPACITIES AND COMPRESSOR INPUT POWER
PF (kW)
TA (°C)
30
PA (kW)
MOD.
TU (°C)
TA (°C)
20
25
35
40
20
25
30
35
40
1
3
5
7
9
11
13
15
1
3
5
7
9
11
13
15
1
3
5
7
9
275.9 258.8 240.9 221.8 201.4
299.9 281.7 262.8 242.7 221.4
325.5 306.1 286.0 264.9 242.5
352.7 332.1 310.7 288.4 264.9
381.7 359.7 337.0 313.4 288.6
412.6 389.0 364.8 339.8 313.7
445.4 420.2 394.5 367.9 340.3
480.3 453.4 425.9 397.8 368.6
304.3 286.5 267.4 246.3 222.8
330.8 311.9 291.8 269.9 245.7
359.1 338.9 317.7 294.8 269.7
389.3 367.7 345.1 321.1 294.9
421.6 398.4 374.3 348.9 321.6
456.1 431.1 405.4 378.5 349.8
493.0 466.0 438.5 409.9 379.7
532.3 503.3 473.8 443.4 411.5
371.3 346.7 321.5 295.9 269.9
403.6 377.4 350.6 323.4 295.7
437.8 410.0 381.6 352.6 323.1
474.2 444.6 414.4 383.7 352.3
512.8 481.4 449.3 416.7 383.4
553.6 520.3 486.4 451.7 416.4
596.9 561.6 525.6 488.9 451.5
642.5 605.2 567.1 528.2 488.6
413.9 388.2 361.3 332.7 302.1
449.9 422.6 394.2 364.1 332.1
488.2 459.2 429.0 397.4 363.8
65.7
66.1
66.5
67.0
67.6
68.2
68.9
69.7
71.3
71.7
72.2
72.7
73.4
74.1
74.9
75.9
90.0
90.6
91.3
92.0
92.8
93.6
94.5
95.4
98.5
99.1
99.8
73.2
73.5
73.8
74.2
74.7
75.2
75.8
76.4
79.7
80.0
80.3
80.7
81.2
81.7
82.4
83.1
81.8
82.1
82.3
82.7
83.0
83.4
83.9
84.4
89.1
89.4
89.7
90.0
90.3
90.7
91.2
91.7
91.8
92.0
92.2
92.4
92.7
93.0
93.3
93.7
99.8
100.1 112.3
100.4 112.6
100.6 112.8
100.9 113.0
101.2 113.3
101.5 113.5
101.9 113.8
103.3
103.5
103.6
103.8
103.9
104.1
104.4
104.6
112.0
300
320
380
430
500
100.0 111.8 125.7 142.0
100.5 112.2 125.9 142.0
101.0 112.6 126.1 142.0
101.6 113.0 126.4 142.1
102.3 113.5 126.8 142.3
103.0 114.1 127.2 142.5
103.8 114.8 127.7 142.8
104.6 115.5 128.3 143.2
109.7 122.7 137.7 155.0
110.2 123.1 138.0 155.2
110.8 123.5 138.3 155.4
11
13
15
1
3
5
7
9
11
13
15
1
3
5
7
9
529.1 498.1 466.1 432.6 397.4 100.6
11.4
124.0 138.7 155.6
572.6 539.5 505.4 470.0 432.9 101.4 112.0 124.5 139.1 155.9
618.9 583.5 547.3 509.7 470.6 102.4 112.8 125.1 139.5 156.2
668.2 630.3 591.7 551.9 510.5 103.4 113.7 125.8 140.0 156.6
720.5 680.0 638.9 596.6 552.9 104.6 114.6 126.5 140.6 157.0
456.4 429.8 401.1 369.5 334.3 107.0 119.5 133.6 149.7 168.0
496.2 467.9 437.7 404.9 368.5 107.6 120.0 134.1 150.1 168.4
538.6 508.4 476.5 442.1 404.5 108.3 120.5 134.5 150.5 168.8
584.0 551.6 517.7 481.6 442.4 109.1 121.1 135.0 150.9 169.2
632.4 597.6 561.5 523.4 482.4 110.0 121.8 135.5 151.3 169.6
684.2 646.7 608.1 567.8 524.7 111.1 122.6 136.1 151.8 169.9
739.5 699.1 657.8 614.9 569.6 112.4 123.5 136.8 152.3 170.3
798.5 754.9 710.7 665.1 617.2 113.8 124.6 137.6 152.9 170.7
11
13
15
TU: Evaporator Outlet water temperature (°C)
TA: Ambient temperature (°C)
PA: Compressors input power (kW)
PF: Cooling capacity (kW)
QLAC / HP / LS (LOW NOISE VERSION)
06617645-02
16
Download from Www.Somanuals.com. All Manuals Search And Download.
HEATING CAPACITIES AND COMPRESSOR INPUT POWER
PC (kW)
TU (°C)
PA (kW)
TU (°C)
MOD.
TA (°C)
30
35
---
40
---
45
---
50
---
55
---
30
9,1
35
---
40
---
45
---
50
---
55
---
-5
0
5
25,1
30,3
36,2
40,2
43,0
51,1
60,5
32,1
37,9
44,8
49,4
52,8
62,1
73,0
37,3
44,2
52,1
57,4
61,2
71,8
84,1
42,3
50,0
59,0
65,0
69,3
81,4
95,5
46,7
55,2
65,1
71,8
76,6
90,0
29,8
35,6
39,4
42,2
49,8
58,8
---
37,5
44,1
48,6
51,8
60,8
71,2
---
43,6
51,2
56,4
60,1
70,2
82,0
---
49,3
58,0
63,8
68,0
79,5
93,0
---
---
---
---
---
---
---
40,7
47,5
55,2
---
---
---
---
---
---
---
---
54,5
---
---
---
---
---
---
65,2
---
---
---
---
---
---
75,0
---
---
---
---
---
---
84,9
---
---
---
---
---
---
93,8
---
---
---
9,2
9,2
9,1
9,1
9,0
9,0
10,2
10,3
10,2
10,2
10,1
10,0
---
12,2
12,3
12,3
12,3
12,2
12,2
---
14,0
14,0
14,0
14,0
13,9
13,8
---
15,4
15,6
15,7
15,7
15,6
15,6
---
17,1
17,3
17,3
17,3
17,4
17,4
---
20,8
21,0
21,0
20,9
20,8
20,8
---
23,8
24,0
24,0
24,1
24,1
24,3
---
26,8
26,9
27,0
27,2
27,5
27,8
---
---
---
---
---
---
14,5
14,6
14,6
---
---
---
---
---
---
---
---
16,6
---
---
---
---
---
---
19,3
---
---
---
---
---
---
22,1
---
---
---
---
---
---
25,0
---
---
---
---
---
---
27,9
---
---
---
---
---
---
33,8
---
---
---
---
---
---
39,0
---
---
---
---
---
---
44,1
35,1
38,8
41,5
48,8
57,3
---
11,5
11,5
11,5
11,4
11,3
---
8
38,5
41,0
48,0
56,1
---
12,9
12,9
12,9
12,9
---
040
10
15
20
-5
0
11,0
11,0
11,0
11,0
11,0
10,9
10,9
12,3
12,5
12,5
12,5
12,5
12,3
12,2
13,7
13,9
14,0
14,0
14,0
13,9
13,9
15,1
15,4
15,5
15,5
15,5
15,5
15,6
18,4
18,7
18,7
18,6
18,6
18,5
18,7
21,1
21,3
21,4
21,4
21,5
21,5
21,7
23,9
23,9
24,1
24,2
24,3
24,6
24,8
---
---
---
---
---
---
5
8
43,5
47,8
50,9
59,5
69,5
---
13,7
13,7
13,7
13,7
13,7
---
47,0
50,2
58,4
67,9
---
---
15,3
15,3
15,4
15,4
---
---
045
050
060
070
080
090
110
10
15
20
-5
0
49,6
57,4
66,5
---
---
---
17,1
17,2
17,2
---
---
---
---
---
---
---
---
---
5
8
50,4
55,4
59,0
68,8
80,1
---
15,6
15,6
15,6
15,6
15,6
---
55,0
58,0
67,4
78,3
---
---
17,4
17,5
17,6
17,5
---
---
10
15
20
-5
0
57,0
66,2
76,6
---
---
---
19,4
19,7
19,7
---
---
---
---
---
---
---
---
---
5
8
57,1
62,7
66,7
77,8
90,7
---
17,4
17,5
17,6
17,6
17,6
---
61,7
65,6
76,3
88,6
---
---
19,5
19,6
19,8
19,8
---
---
10
15
20
-5
0
64,6
74,9
86,7
---
---
---
21,9
22,2
22,3
---
---
---
54,5
64,0
70,4
75,0
87,8
---
---
---
---
---
---
5
8
63,1
69,2
73,7
85,9
19,3
19,4
19,5
19,5
19,6
---
68,2
72,5
84,2
97,8
---
---
---
82,8
88,0
---
21,7
21,8
22,0
22,0
---
---
10
15
20
-5
0
71,5
82,7
95,7
---
---
---
24,4
24,7
24,8
---
---
---
105,6 102,8 100,2
56,3
66,8
78,6
86,6
92,3
---
---
---
76,5
83,9
89,2
65,9
77,5
85,2
90,7
---
---
---
5
8
23,5
23,6
23,6
23,5
23,4
---
---
86,8
---
---
---
26,4
26,5
26,6
26,5
---
---
10
15
20
-5
0
29,7
30,0
30,0
---
---
---
108,4 106,0 103,9 102,1 100,5
127,3 124,0 121,0 118,3 116,0 113,9
64,7
76,5
90,4
99,8
106,5 104,3 102,3 100,5
125,4 122,4 119,6 117,1 114,8
147,3 143,4 139,8 136,4 133,2 130,3
73,4
86,7
102,7 100,6
113,6 111,0 108,7 106,7
121,4 118,6 115,9 113,5 111,5
143,2 139,6 136,1 132,7 129,7
168,2 163,9 159,5 155,2 151,1 147,4
---
---
---
87,4
96,0
---
---
---
---
---
---
---
98,9
---
---
---
---
---
---
75,5
88,8
97,8
---
---
---
5
8
26,9
27,0
27,0
27,1
27,2
---
94,5
30,3
30,4
30,5
30,6
---
---
---
34,2
34,2
34,5
34,8
---
10
15
20
-5
0
5
8
10
15
20
34,2
34,4
34,5
---
---
---
---
---
98,8
---
---
---
---
---
---
---
---
---
---
---
---
---
85,4
---
30,3
30,3
30,4
30,7
31,1
---
38,7
38,8
39,1
TU: Outlet water temperature (°C)
TA: Ambient temperature dry bulb (°C)
PA: Compressors input power (kW)
PH: Heating capacity (kW)
06617645-02
17
Download from Www.Somanuals.com. All Manuals Search And Download.
QLAC / HP / LS (LOW NOISE VERSION)
HEATING CAPACITIES AND COMPRESSOR INPUT POWER
PC (kW)
TU (°C)
PA (kW)
TU (°C)
MOD.
TA (°C)
30
82,2
97,9
35
---
96,1
40
---
---
45
---
---
---
50
---
---
---
---
55
---
---
---
---
---
---
30
35
---
40
---
---
34,1
34,2
34,2
34,5
34,8
---
45
---
---
50
---
---
---
---
43,7
43,7
43,8
---
---
---
55
---
---
---
---
---
---
49,4
---
---
---
---
---
---
54,7
---
---
---
---
---
---
61,8
---
---
---
---
---
---
67,7
---
---
---
---
---
---
77,9
---
---
---
---
---
---
88,1
---
---
---
---
---
---
98,8
---
---
---
---
---
---
-5
0
5
26,8
26,8
27,0
27,2
27,3
27,7
28,1
29,6
29,8
30,0
30,2
30,3
30,8
31,3
33,5
34,1
34,2
34,1
34,1
34,0
34,3
36,7
37,4
37,4
37,3
37,1
37,0
37,4
42,3
42,6
42,8
42,9
42,9
43,1
43,5
47,8
47,8
48,1
48,5
48,7
49,2
49,6
53,5
53,7
54,1
54,4
54,7
55,4
56,1
59,3
59,5
60,0
60,4
60,7
61,6
62,7
30,2
30,3
30,4
30,5
30,8
31,2
---
33,5
33,6
33,8
33,9
34,2
34,6
---
37,9
38,3
38,3
38,3
38,2
38,2
---
41,6
42,0
42,0
41,9
41,6
41,6
---
47,6
47,9
48,0
48,1
48,3
48,5
---
53,7
53,8
54,1
54,3
54,9
55,5
---
60,4
60,6
60,8
61,0
61,7
62,4
---
67,1
67,3
67,5
67,7
68,4
69,3
116,6 113,8 111,5
129,3 126,0 123,0 120,4
138,5 134,8 131,3 128,3 125,8
164,1 159,3 154,7 150,4 146,7
193,7 187,7 181,8 176,3 171,1 166,5
89,5
107,3 105,1
128,2 124,9 122,2
142,5 138,5 135,0 132,1
152,8 148,3 144,2 140,8 138,1
181,5 175,6 170,2 165,2 160,9
215,0 207,5 200,4 193,8 187,9 182,6
102,1
120,8 119,3
142,2 140,1 138,3
156,7 154,1 151,7 149,7
167,1 164,0 161,3 159,0 157,0
196,2 191,8 187,9 184,5 181,5
230,3 224,3 218,8 214,0 209,6 205,8
112,0
132,6 131,0
156,1 153,9 152,0
171,9 169,2 166,8 164,6
183,3 180,1 177,3 174,8 172,6
215,1 210,5 206,4 202,8 199,6
252,7 246,1 240,2 235,0 230,5 226,4
129,4
153,1 150,9
180,7 177,6 174,7
199,5 195,6 192,1 189,0
213,0 208,6 204,6 200,9 197,8
250,8 244,8 239,3 234,1 229,5
294,6 286,9 279,6 272,7 266,4 260,6
149,4
176,9 174,0
209,6 205,2 201,3
232,0 226,6 221,7 217,3
248,1 242,1 236,5 231,4 227,0
292,8 285,3 277,9 270,8 264,4
344,3 335,1 326,0 316,9 308,4 300,4
165,3
197,1 193,4
234,8 229,2 224,3
260,5 253,7 247,6 242,4
279,0 271,4 264,4 258,3 253,2
330,7 320,8 311,5 302,9 295,2
390,4 378,2 366,3 355,0 344,6 335,1
181,2
217,3 212,7
259,9 253,1 247,4
289,0 280,7 273,5 267,4
310,0 300,7 292,3 285,1 279,3
368,5 356,4 345,1 334,9 326,0
436,5 421,2 406,7 393,1 380,8 369,8
---
8
38,6
38,6
38,7
39,0
---
120
10
15
20
-5
0
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
5
38,0
38,0
38,0
38,2
38,6
---
8
42,9
42,9
43,0
43,2
---
---
130
140
160
190
210
240
260
10
15
20
-5
0
48,6
48,5
48,5
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
5
8
42,8
43,0
43,1
43,0
42,9
---
48,2
48,4
48,6
48,5
---
---
10
15
20
-5
0
54,1
54,7
54,8
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
5
8
47,0
47,2
47,2
47,0
46,8
---
52,9
53,1
53,2
52,9
---
---
10
15
20
-5
0
59,4
60,0
59,9
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
5
8
53,8
54,0
54,0
54,2
54,4
---
60,7
60,8
61,1
61,3
---
---
10
15
20
-5
0
68,4
68,8
69,1
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
5
8
60,6
60,7
60,8
61,4
62,1
---
68,4
68,5
68,9
69,6
---
---
10
15
20
-5
0
77,5
77,7
78,2
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
5
8
68,2
68,3
68,5
68,9
69,6
---
77,2
77,2
77,4
78,0
---
---
---
85,9
85,8
85,9
86,3
---
10
15
20
-5
0
5
8
10
15
20
87,3
87,3
87,6
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
75,9
76,0
76,1
76,5
77,1
---
97,2
97,0
97,0
109,4
TU: Outlet water temperature (°C)
TA: Ambient temperature dry bulb (°C)
PA: Compressors input power (kW)
PH: Heating capacity (kW)
06617645-02
18
Download from Www.Somanuals.com. All Manuals Search And Download.
EVAPORATOR PRESSURE DROPS
80
70
60
50
40
30
20
10
80
70
A
B
E
G
H
C
60
D
F
50
40
30
20
10
15000
20000
25000
30000
5000
10000
15000
20000
A: QLAC 040-045
B: QLAC 050
C: QLAC 060-070
D: QLAC 080
E: QLAC 090
F: QLAC 110
G: QLAC 120
H: QLAC 130
80
70
60
50
40
30
20
10
60
Q
R
T
S
50
40
30
20
10
I
L
M
N
O
P
U
25000
30000
35000
40000
45000
50000
40000
50000
60000
70000
80000
90000
I: QLAC 140
L: QLAC 160
M: QLAC 190
N: QLAC 210
O: QLAC 240
P: QLAC 260
Q: QLAC 300
R: QLAC 320
S: QLAC 380
T: QLAC 430
U: QLAC 500
06617645-02
19
Download from Www.Somanuals.com. All Manuals Search And Download.
WATER PUMPS AVAILABLE STATIC PRESSURE
240
220
200
180
160
140
120
100
80
220
D
200
B
180
A
C
160
140
120
100
80
60
60
40
5000
10000
15000
20000
15000
20000
25000
30000
A: QLAC 040,045,050,060,070
B: QLAC 080, 090
C: QLAC 110, 120
D: QLAC 130, 140
240
220
200
180
160
140
120
100
80
220
H
E
200
180
160
140
120
100
F
G
20000 25000 30000 35000 40000 45000 50000
50000
60000
70000
80000
90000
E: QLAC 160,190,210
F: QLAC 240, 260
G: QLAC 300, 320
H: QLAC 380, 430, 500
06617645-02
20
Download from Www.Somanuals.com. All Manuals Search And Download.
FREE COOLING CAPACITY
3
2,5
2
7°C
5°C
12°C
10°C
1,5
1
Return water temperature 15°C
0,5
0
-20
-15
-10
-5
0
5
10
Ambient air temperature (°C)
040
---
045
---
050
43
060
43
070
43
080
45
090
70
110
72
Mod.
Nominal Free cooling capacity
Mod.
kW
kW
kW
120
72
130
72
140
94
160
94
190
110
500
240
210
115
240
135
260
135
Nominal Free cooling capacity
Mod.
300
185
320
185
380
235
430
245
Nominal Free cooling capacity
The nominal Free Cooling capacity is obtained when all compressors are OFF, the return water temperature
from the system is 15°C and the ambient temperature is 2°C. to calculate the free cooling capacity in
different conditions please refer to the above diagram. To obtain free cooling duty multiply the nominal Free
Cooling capacity by the CFC factor obtained.
06617645-02
21
Download from Www.Somanuals.com. All Manuals Search And Download.
PARTIAL HEAT RECOVERY CAPACITY
Mod.
040
9,5
045
12,8
2200
14
050
13,0
2240
11
060
15,0
2580
15
070
15,3
2630
16
080
18,5
3190
18
090
21,5
3700
11
110
24,8
4270
15
Partial heat recovery nominal capacity
Water flow
kW
l/h
1635
10
Water pressure drops
Mod.
kPa
120
27,5
4730
13
130
30,0
5160
18
140
34,0
5850
18
160
190
43,0
7400
11
210
49,0
8430
15
240
55,0
9460
19
260
Partial heat recovery nominal capacity
Water flow
kW
l/h
37,0
6360
25
61,5
10570
25
Water pressure drops
Mod.
kPa
300
69,0
11850
20
320
76,0
13000
25
380
91,5
15750
25
430
500
114
19600
35
Partial heat recovery nominal capacity
Water flow
kW
l/h
102,8
17700
29
Water pressure drops
kPa
The nominal value refers to an ambient temperature 35°C and outlet water temperature 50°C (Dt 5°C).
1,5
1,4
1,3
1,2
1,1
1
Ambient temperature 40°C
Ambient temperature 35°C
Ambient temperature 30°C
Ambient temperature 25°C
Ambient temperature 20°C
0,9
0,8
40
41
42
43
44
45
46
47
48
49
50
Outlet water temperature °C
The heat recovery capacity in different conditions can be obtained multiplying the nominal capacity (See above), by the correction
factor indicated in the table.
Warning Partial heat recovery can only work in cooling mode. In the heat pump version it is
necessary to isolate the heat recovery circuit when in heating mode to prevent damage.
Failure to comply with this will invalidate the warranty.
06617645-02
22
Download from Www.Somanuals.com. All Manuals Search And Download.
COMPRESSORS CAPACITY STEP CONTROLS
CORRECTION TABLE
Glycol
Operation with glycol
WFCF
Water temp.
PDCF
10%
20%
35%
10%
20%
35%
10%
20%
35%
10%
20%
35%
1,012
1,048
1,109
0,870
0,875
0,925
0,710
0,730
0,770
---
1,125
1,32
1,62
0,85
0,92
1,13
0,64
0,85
1,05
---
7
3
-2
-5
0,600
0,625
0,56
0,7
WFCF = Water flow correction factor
PDCF = Pressure drop correction factor
The water flow rate and pressure drop correction factors are to be applied directly to the values given for
operation without glycol. The water flow rate correction factor is calculated in order to maintain the same
temperature difference as that which would be obtained without glycol. The pressure drop correction factor
takes into account the different flow rate obtained from the application of the flow rate correction factor.
When the new flow rate is determind the capacity can be calculated using the formula Q=4.19m ΔT, where Q
is the duty in kw, m is the flow rate in kg/s and ΔT is the fluid temperature difference.
CORRECTION TABLES
3
Different DT
5
Water temperature
difference
CCCP
8
0,99
0,99
1
1
1,02
1,01
IPCF
CCCP = Cooling capacity correction factor IPCF = Input power correction factor
CORRECTION TABLES
0,00005
Different Fouling factors
0,0001
Fouling factor
0,0002
CCCP
IPCF
1
1
0,98
0,98
0,94
0,95
CCCP = Cooling capacity correction factor IPCF = Input power correction factor
06617645-02
23
Download from Www.Somanuals.com. All Manuals Search And Download.
ELECTRICAL DATA
Model
Power line fuses
040
50
045
63
050
63
060
80
070
100
080
100
090
125
110
125
A
10
10
16
16
25
25
25
35
mm²
Power line cable section
Model
120
130
140
160
190
210
240
260
160
200
200
200
250
250
350
400
A
Power line fuses
Power line cable section
50
50
50
50
70
95
120
150
mm²
400 / 3 / 50
230 / 1 / 50
24 / 1 / 50
V/~/Hz
V/~/Hz
V/~/Hz
V/~/Hz
Power supply
Auxiliary circuit
Control board
Fans power supply
400 / 3 / 50
Electrical data varies depending on specification. Always refer to the wiring diagram supplied in the unit.
SOUND LEVELS LOW NOISE VERSION
Octave bands (Hz)
Lw
Lp
Model
63
dB
125
dB
250
dB
500
dB
1K
dB
2K
dB
4K
dB
8K
dB
dB
dB(A)
dB(A)
040/LS
045/LS
050/LS
060/LS
070/LS
080/LS
090/LS
110/LS
120/LS
130/LS
140/LS
160/LS
190/LS
210/LS
240/LS
260/LS
300/LS
320/LS
380/LS
430/LS
500/LS
90.1
90.1
92.1
92.1
93.1
93.1
95.1
95.6
96.0
96.2
96.6
97.1
99.1
99.1
102.1
102.1
103.1
103.1
104.1
104.1
104.1
91.3
91.3
83.3
83.3
84.3
84.3
86.3
86.8
87.2
87.4
87.8
88.3
90.3
90.3
93.3
93.3
94.3
94.3
95.3
95.3
95.3
75.2
75.2
77.2
77.2
78.2
78.2
80.2
80.7
81.1
81.3
81.7
82.2
84.2
84.2
87.2
87.2
88.2
88.2
89.2
89.2
89.2
73.3
73.3
75.7
75.7
76.7
76.7
78.7
79.2
79.6
79.8
80.2
80.7
82.7
82.7
85.7
85.7
86.7
86.7
87.7
87.7
87.7
72.6
72.6
74.6
74.6
75.6
75.6
77.6
78.1
78.5
78.7
79.1
79.6
81.6
81.6
84.6
84.6
85.6
85.6
86.6
86.6
86.6
67.2
67.2
69.2
69.2
70.2
70.2
72.2
72.7
73.1
73.3
73.7
74.2
76.2
76.2
79.2
79.2
80.2
80.2
81.2
81.2
81.2
63.8
63.8
65.8
65.8
66.8
66.8
68.8
69.3
69.7
69.9
70.3
70.8
72.8
72.8
75.8
75.8
76.8
76.8
77.8
77.8
77.8
54.7
54.7
56.7
56.7
57.7
57.7
59.7
60.2
60.6
60.8
61.2
61.7
63.7
63.7
66.7
66.7
67.7
67.7
68.7
68.7
68.7
90.9
90.9
92.9
92.9
93.9
93.9
95.9
96.4
96.8
97.0
97.4
98.0
99.9
77.0
77.0
79.0
79.0
80.0
80.0
82.0
82.5
82.9
83.1
83.5
84.0
86.0
86.0
89.0
89.0
90.0
90.0
91.0
91.0
91.0
49
49
51
51
52
52
54
54.5
54.9
55.1
55.5
56
58
58
61
61
62
62
63
63
99.9
102.9
102.9
103.9
103.9
104.9
104.9
104.9
63
SOUND LEVELS EXTRA LOW NOISE VERSION
Octave bands (Hz)
Lw
Lp
Model
63
dB
125
dB
250
dB
500
dB
1K
dB
2K
dB
4K
dB
8K
dB
dB
dB(A)
dB(A)
040/XL
045/XL
050/XL
060/XL
070/XL
080/XL
090/XL
110/XL
120/XL
130/XL
140/XL
160/XL
190/XL
210/XL
240/XL
260/XL
300/XL
320/XL
380/XL
430/XL
500/XL
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
48
48
50
89.1
89.1
91.1
91.1
92.6
93.0
93.2
93.6
94.1
94.4
97.1
97.1
---
---
---
---
---
---
---
80.3
80.3
82.3
82.3
83.8
84.2
84.4
84.8
85.3
85.6
88.3
88.3
---
---
---
---
---
---
---
74.2
74.2
76.2
76.2
77.7
78.1
78.3
78.7
79.2
79.5
82.2
82.2
---
---
---
---
---
---
---
72.7
72.7
74.7
74.7
76.2
76.6
76.8
77.2
77.7
78.0
80.7
80.7
---
---
---
---
---
---
---
71.6
71.6
73.6
73.6
75.1
75.5
75.7
76.1
76.6
76.9
79.6
79.6
---
---
---
---
---
---
---
66.2
66.2
68.2
68.2
69.7
70.1
70.3
70.7
71.2
71.5
74.2
74.2
---
---
---
---
---
---
---
62.2
62.2
64.8
64.8
66.3
66.7
66.9
67.3
67.8
68.1
70.8
70.8
---
---
---
---
---
---
---
53.7
53.7
55.7
55.7
57.2
57.6
57.8
58.2
58.7
59.0
61.7
61.7
---
---
---
---
---
---
---
89.9
89.9
91.9
91.9
93.4
93.8
94.0
94.4
95.0
95.3
98.0
98.0
---
---
---
---
---
---
---
76.0
76.0
78.0
78.0
79.5
79.9
80.1
80.5
81.0
81.3
84.0
84.0
---
---
---
---
---
---
---
50
51.5
51.9
52.1
52.5
53
53.3
58
58
---
---
---
---
---
---
---
--- (not availble)
Lw – Sound power level according to ISO 3746.
Lp – Sound pressure level measured at 10 mt from the unit in free field conditions direction factor Q = 2 according to ISO 3746.
06617645-02
24
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions – General
- When installing or servicing the unit, you must follow the instructions given in this manual and on labels
attached to the unit.
- As the chiller is charged with refrigerant under pressure and unauthorised access to the electrical
components provides a shock hazard, any work performed on the unit must be by suitably trained
personnel only.
- Failure to observe the instructions provided in this manual, or any modification of the unit without explicit
previous authorisation, will invalidate the warranty.
Attention: before servicing the unit ensure that the electric supply is disconnected.
Inspection
After receiving the unit, immediately check its integrity. The unit left the factory in perfect condition; any
eventual damage must be reported to the carrier and be recorded on the Delivery Note before it is signed.
TEV Ltd must be informed, within 8 days, of the extent of the damage. The customer should prepare a
written statement of any severe damage: digital photos of any damage is useful.
Lifting and site handling
When unloading the unit, care must be taken to prevent damage to the refrigerant circuit, condensing coils
or unit casing.
When using a crane, pass bars through the base frame lifting holes (marked with yellow arrows) and attach
the cable or chains to these bars. Ensure that they are clamped firmly. Protect the sides of the chiller with
boarding or material of a similar nature.
Forklift forks must be inserted in the base pallet: care must be taken to prevent them hitting the base or
panels. Keep the unit horizontal to avoid damage to the internal components.
IMPORTANT: be sure that the method of lifting does not allow the unit to slip from chains or slings,
turn over or slide from lifting devices.
Unpacking
When unpacking, be careful not to damage the unit. The packing is made up of different materials: wood,
cardboard, polythene etc. We recommend that they are sent to a re-cycling centre in order to reduce their
environmental impact.
LOCATION AND MINIMUM CLEARANCES
QLAC units are designed for external installation. Any overhang or cover above the unit should be avoided
as this can cause air re-circulation. It is advisable to create a firm base for the unit, with a size similar to unit
foot-print. Normal unit vibration levels are very low: it is good practice, however, to fit a rigid rubber interface
between base and unit frame. Where desirable, fit anti-vibration mounts (spring or rubber), to keep vibration
to a minimum. For future maintenance, these clearances are recommended:-
Mod.
040
045
050
060
070
080
090
110
120
130
140
160
190
210
240
260
300
320
380
430
500
A
B
800
800
800
800
800
800
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
C
800
800
800
800
800
800
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
2000
2000
2000
2000
2000
D
800
800
800
800
800
800
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
2000
2000
2000
2000
2000
E
1000
1000
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
2000
2000
2000
2000
2000
2000
2000
2000
2000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
4000
4000
4000
4000
4000
4000
5000
5000
5000
5000
5000
Warning: The unit should be installed such that there is suitable access for maintenance and/or
repair.
06617645-02
25
Download from Www.Somanuals.com. All Manuals Search And Download.
HYDRAULIC CONNECTIONS
Unit water pipe-work must be installed in accordance with national and local regulations. Pipes can be steel,
galvanized steel, copper or PVC. Pipes have to be designed depending on the nominal water flow and the
hydraulic pressure drops of the system. All pipes must be insulated with closed-cell material of adequate
thickness. The chiller must be connected to the pipework using flexible joints. Piping should include:
•
•
•
•
Temperature and pressure gauges for maintenance or servicing operations.
Manual shut-off valves to separate the unit from the hydraulic circuit.
Metallic supply water filter to be sited at the inlet pipe, with a mesh not larger than 1 mm.
Vent valves, expansion tank with water filling, discharge valve.
The water inlet must correspond with the connection labelled ”USER WATER INLET”, otherwise the
evaporator may freeze.
You must fit a metallic filter with a mesh not larger than 1 mm at the ‘USER WATER INLET’
connection. If the flow switch is altered or the water filter is not fitted, the warranty will be
invalidated. All units are supplied with flow switch, on ‘K’ versions it is factory installed, on standard
versions it is supplied loose. The flow switch MUST be installed on the water outlet pipe. Please refer
to the wiring diagram for the flow switch electrical connections
LAC
Standard
LAC / K
A
B
C
D
E
Water tank
F
G
H
I
Water strainer
Water pump
Expansion vessel
Safety valve
Flexible connection
Ball shut-off valve
Vent valve
System filling group
06617645-02
26
Download from Www.Somanuals.com. All Manuals Search And Download.
(QLAC / FC FREE COOLING VERSION)
FREE COOLING SYSTEMS MUST ALWAYS BE FILLED WITH GLYCOL SOLUTION
The free cooling versions can operate in 3 different operating modes. The free-cooling coil is installed in
series with the water chiller evaporator; the 3 way valve controls the water flow through the coil. When the
ambient temperature is lower than the return water temperature, the microprocessor allows the water flow to
pass through the free-cooling coil first, then through the evaporator.
Cooling mode (Summer operation) Ambient temperature is higher than the return water temperature. In
this case, the ambient conditions are not suitable to allow Free Cooling operation; the 3 way valve is closed
and the water flows to the evaporator, where it is cooled. The compressors, fans, and the water pump are
activated; the unit operates like a normal liquid cooler.
Free cooling mode (Winter operation) Ambient temperature is much lower than the return water
temperature. In this case, the ambient conditions are suitable to allow Free Cooling operation; the 3 way
valve opens and the water flows into the free cooling coil, where the ambient conditions are sufficient to give
the total required load. In this case the pump and the fans are in operation, while the compressors are
stopped. In this case, the free cooling system works in substitution of the water chiller.
Cooling mode + Free cooling (Mid-season operation) Ambient temperature is lower than the return water
temperature. In this case, the ambient conditions are suitable to allow Free Cooling operation; the 3 way
valve opens and water flow passes into the free cooling coil although the ambient conditions are not
sufficiently low to give the total required load. The microprocessor control activates the compressors (pump
and fans are already in operation) to satisfy the required load. In this case the free cooling system works in
conjunction with the water chiller. In these circumstances the head pressure control device is activated.
CONDENSING PRESSURE CONTROL (optional)
If unit operation below 20°C is expected, a condensing pressure control must be fitted in the unit. This
device will allow unit operation under low ambient temperature, by reducing condenser air flow and
obtaining acceptable operating parameters. This device modulates the fan speed in proportion to the
condensing pressure measured by the pressure transducer.
This device is factory pre-set. The values must never be modified.
OPERATIONAL LIMITS
Evaporator water flow rate
The nominal water flow rates are based on a delta T (Win - Wout) of 5 °C. The maximum flow rate allowed is
that achieved with a delta T of 3 °C: higher values may cause too high pressure drop. The minimum water
flow rate allowed is that achieved with a delta T of 8 °C. Insufficient values cause too low evaporating
temperatures, tripping safety devices which stop the unit.
Chilled water temperature (summer operation)
The minimum temperature allowed at the evaporator outlet is 5 °C. To work below this limit, the unit
requires modification - please contact TEV Ltd. The maximum temperature allowed at the evaporator inlet is
20 °C.
Hot water temperature (winter operation)
Once the system is at temperature, the water temperature at the condenser inlet should not be less than 23
°C: lower values could cause incorrect working operation of the compressor and compressor failure may
occur. The maximum water temperature at the condenser outlet should not exceed 48 °C: higher values will
cause safety devices to trip and stop operation.
Ambient air temperature
The units are designed and manufactured to operate, in cooling, with ambient air temperature between 20°C
to 42 °C If a fan speed control is installed then the minimum ambient air temperature is -10°C. In winter
operation (heat pump cycle) operates from -5°C to 20°C.
06617645-02
27
Download from Www.Somanuals.com. All Manuals Search And Download.
ELECTRICAL CONNECTIONS
Disconnect the electrical supply before undertaking any work on the unit.
All electrical work must be undertaken by suitably qualified personnel.
The electrical supply must match the nominal electrical data (voltage, phase, frequency) shown on the label
in the front panel of the unit. Power connections must be made in accordance to the wiring diagram enclosed
with the unit and in accordance current local and national regulations. Power cable and line protection must
be sized according to the specification stated on the wiring diagram enclosed with the unit.
The variation in line voltage must not be more than ±5% of the nominal value, whilst the voltage imbalance
between phases must not exceed 2%. If those tolerances are likely to be exceeded, please contact TEV
Ltd., as further protection devices are required.
Electrical supply must be as described, otherwise warranty will be invalid.
START UP
Before start-up
- Check that all power cables are connected in the correct sequence and that all terminals are tight.
- The voltage measured at the R Y B phase clamps must be 400 V ± 5% (or the value given on the rating
plate for special voltages). If the voltage is incorrect, do not proceed.
- Check for any refrigerant leaks using a leak detector. Should a leak be found do not proceed. All leaks
must be rectified and the unit re-charged by trained personnel.
- Check that the crankcase heaters are energised.
Crankcase heaters must be energised at least 12 hours before start up by switching on the unit at
the main switch.
- Verify that heaters are working correctly. After a short warm up period, the compressor crankcase must be
warm to the touch and must have a temperature at least 10K higher than ambient temperature.
- Check that all hydraulic connections have been made correctly and that all information given on the unit's
labels have been observed.
- The system must be filled with water and bled to eliminate any air.
Caution: before starting the unit up, check that all cover panels are correctly located and securely
fastened.
Start up
Please refer to the microprocessor manual enclosed with the unit.
If the unit fails to start:
• Check that the control thermostat is set to the correct value.
• Do not modify any internal wiring, otherwise warranty will be invalidated.
Controls during unit operation
• Check the rotation of the fans. If the rotation is incorrect, disconnect the main switch and change over any
two phases of the incoming main supply to reverse motor rotation:
• Check that water temperature at evaporator inlet is near to the set point of the control thermostat.
• For “K” version units (units with pumps and storage tank) if the motor driven pump is noisy, slowly
close the discharge shut-off valve until normal working conditions are restored.
This trouble may occur when system pressure drop is significantly different from pump available
pressure.
06617645-02
28
Download from Www.Somanuals.com. All Manuals Search And Download.
Refrigerant charge checking
• A few minutes after start up, working on cooling operating mode, check that condensing temperature, is
approximately 15 °C higher than condenser inlet air temperature. Also check that the evaporation
temperature is about 5 °C lower than the evaporator outlet temperature.
• When the unit has stabilised, check that the sight glass core shows green: if the core is yellow,
moisture is present in the circuit. In this case it is necessary to dehydrate the circuit (qualified personnel
only). Check at the sight glass that there are no continuous vapour bubbles present. If so, additional
refrigerant charge may be required. (A few vapour bubbles are acceptable).
• Check that refrigerant superheat on the evaporator is about 5-7 °C
• Check if refrigerant sub-cooling on the condenser is about 5-7 °C.
Unit switch OFF
Please refer to the microprocessor manual enclosed with the unit.
Caution: For temporary stops (night time, weekend etc.) never switch off the unit by opening the mains
switch: this should only be used to disconnect the unit from the power supply when current is not
passing through it, i.e. when the unit is in ‘OFF’ mode. Additionally, with no supply to the crankcase
heater, the compressor could be seriously damaged at unit start up.
CONTROL AND SAFETY DEVICE SETTINGS
Control devices - factory settings
CAPACITY STEPS
2
4
CONTROL DEVICE
Set-point Differential Set point Differential
10
42
2
2
9
43
3
3
Control thermostat (cooling)
Control thermostat (heating)
°C
°C
Safety devices - factory settings
CONTROL DEVICE
Anti-freeze thermostat
Electric heater thermostat
High pressure switch
Low pressure switch
End defrosting pressure
Defrosting set-point
SET POINT
DIFFERENTIAL
RESET TYPE
Manual
4
4
6
6
7
1
--
2
--
°C
°C
Manual
Manual
Manual
Automatic
Automatic
--
28
0,7
18
16
6
bar
bar
bar
bar
bar
Water safety valve (Optional)
06617645-02
29
Download from Www.Somanuals.com. All Manuals Search And Download.
MAINTENANCE AND PERIODIC CHECKS
All maintenance and service operations MUST BE CARRIED OUT BY TRAINED PERSONNEL.
Disconnect the electrical supply before undertaking any work on the unit. (Any servicing performed
when the supply is connected will need a suitable risk assessment).
The compressor casing and discharge line of the compressor are usually hot. Care should be taken
when working in this area. Aluminium coil fins are very sharp and can cause serious wounds. Care
should be taken when working in this area. After any servicing operation ensure that all covers are
replaced and fastened with their locking screws.
It is strongly recommended that regular maintenance checks are performed to maintain correct
operation of the unit:-
Every three months:
- Check that safety and control devices work correctly as previously described.
- Check all the terminals on the electric board and on the compressor are tight. Periodic cleaning of the
terminals of the contactors should be done: if any damage is found, please replace the contactors.
- Verify refrigerant charge by checking the sight glass.
- Check that there is no oil leakage from the compressor.
- Check that there is no water leakage from the hydraulic system.
- If the unit is to be stopped for a long period, the unit hydraulic circuit, including all internal pipework and
heat exchanger, should be emptied. This operation is compulsory if, during a seasonal shutdown, the
ambient temperature is expected to go below the freezing point of the fluid in the hydraulic circuit (typical
seasonal operation).
- Check hydraulic circuit water level.
- Check the flow switch operation .
- Check the compressor crankcase heater power supply and operation.
- Check defrosting procedure.
- Clean drain pan and pipeline.
- Clean mesh on water strainers.
- Clean the finned coils metallic filters with compressed air. This should be in the opposite direction of the
normal air flow. If filters become fully clogged, clean them with a water jet.
Every six months:
- Check the colour of the sight glass core (green = no moisture, yellow = moisture present).
If it is yellow, the refrigerant circuit should be dehydrated and the refrigerant filter/drier changed.
- Check the unit noise level.
- Check mounting of fan blades and their balancing, check the tension and the wear of the belt.
REFRIGERANT CIRCUIT REPAIR
If the refrigerant circuits need to be evacuated,, all the refrigerant must be recovered using suitable
equipment. The system must be charged with nitrogen, using a gas bottle with a pressure reducing valve,
until 15 bar pressure is reached. Search for leaks with a bubble leak finder. If bubbles appear, discharge
the circuit before repairing by brazing with a suitable braze alloy. Never use oxygen instead of nitrogen:
explosions may occur.
06617645-02
30
Download from Www.Somanuals.com. All Manuals Search And Download.
Environmental Protection
European legislation regarding the use of ozone depleting substances forbids the release of refrigerants to
the atmosphere. They must be reclaimed and returned to the vendor, or to authorised re-cyclers at the end
of their operating life.
R407C refrigerant is deemed to be a controlled substance and is therefore subject to this legislation.
Particular care is required during servicing operations in order to prevent refrigerant loss.
De-commissioning
When the unit reaches the end of its service life and requires removal or replacement, the following
operations are recommended:-
- the unit refrigerant must be reclaimed by trained personnel and returned to an authorised re-cycling centre
- compressor lubricating oil should be recovered and sent to an authorised re-cycling centre
- the unit frame, coil, heat exchanger etc, should be dismantled and subdivided into material type; bear in
mind that copper and aluminium are present in substantial quantities in the unit.
These operations aid material recovery and recycling processes, reducing environmental impact.
06617645-02
31
Download from Www.Somanuals.com. All Manuals Search And Download.
DIMENSIONS
06617645-02
32
Download from Www.Somanuals.com. All Manuals Search And Download.
06617645-02
33
Download from Www.Somanuals.com. All Manuals Search And Download.
06617645-02
34
Download from Www.Somanuals.com. All Manuals Search And Download.
06617645-02
35
Download from Www.Somanuals.com. All Manuals Search And Download.
06617645-02
36
Download from Www.Somanuals.com. All Manuals Search And Download.
06617645-02
37
Download from Www.Somanuals.com. All Manuals Search And Download.
06617645-02
38
Download from Www.Somanuals.com. All Manuals Search And Download.
06617645-02
39
Download from Www.Somanuals.com. All Manuals Search And Download.
06617645-02
40