Quartz Water Heater 06617645 02 User Guide

QLAC  
TECHNICAL MANUAL  
AIR COOLED WATER CHILLERS AND HEAT PUMPS WITH AXIAL FANS  
06617645-02  
TEV LTD, ARMYTAGE ROAD, BRIGHOUSE, WEST YORKSHIRE, HD6 1QF. TEL: + 44 (0) 1484 405630 FAX: +44 (0) 1484 405620  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EC DECLARATION OF CONFORMITY  
Herewith TEV Ltd declare that the air conditioning equipment designated below is in accordance with the essential  
requirements of current EC Directives.  
This declaration is based on the design and construction of the equipment in the form brought onto the market by TEV Ltd.  
If alterations are made to the machinery without prior consultation with TEV Ltd. this declaration becomes invalid.  
Relevant EC Council Directives:  
Machinery Directive (98/37/EC)  
EMC Directive (89/336/EEC in the versions 93/68/EEC)  
Low Voltage Directive (73/23/EEC in the version 93/68/EEC)  
Directive PED (97/23/EC)  
Applied harmonised standards:  
Basis of self attestation:  
EN 292-1:1991, EN 292-2:1991, EN 294:1992, EN 349:1993, EN 55014-1:2000,  
EN 55014-2:1997, EN 60335-1:2002, EN 60335-2-40:2003, EN 61000-3:1995  
BS EN ISO 9001:2000  
BSI registered firm certificate no. FM671  
EG KONFORMITÄTSERKLÄRUNG  
Hiermit erklärt TEV Ltd, daß die unten angegebenen Klimageräte in Übereinstimmung mit den Gesundheits - und  
Sicherheitsbestimmungen der gültigen EG-Direktiven stehen.  
Diese Erklärung bezieht sich auf die Konzeption und die Konstruktion der Geräte, die von TEV Ltd. auf den Markt gebracht  
werden.  
Wenn Veränderungen an den Geräten ohne vorherige Absprache mit TEV Ltd. gemacht werden, so wird diese Erklärung  
ungültig.  
Relevante EG Richtlinien:  
Maschinen - Richtlinien (Version 98/37/EWG)  
EMV Direktive: (89/336/EWG/EEC in den Versionen 93/68/EWG)  
Niederspannungsrichtlinie: (73/23/EWG/EEC in der Version 93/68/EWG)  
Richtlinien PED (97/23/EC)  
Angewandte Standard  
Normen:  
EN 292-1:1991, EN 292-2:1991, EN 294:1992, EN 349:1993, EN 55014-1:2000,  
EN 55014-2:1997, EN 60335-1:2002, EN 60335-2-40:2003, EN 61000-3:1995  
Bestätigungsgrundlage:  
BS EN ISO 9001:2000  
Zertifikat Nr. FM 671  
Model Name:  
Nom du modèle:  
Nombre del Modelo:  
Machinebeschrijving:  
Modellname:  
Serial Number:  
Numéro de série:  
Numéro de Serie:  
Serienummer:  
Serienummer:  
Model Part Number:  
Référence du modèle:  
Artikelnummer:  
Modellnummer:  
Número de la Parte del Modelo:  
Signature of TEV Ltd. designated Handtekening van de gemachtigde  
"responsible person":  
persoon bij TEV Ltd.:  
Unterschrift von TEV Ltd.  
"verantwortliche Person":  
Signature d' TEV Ltd Le responsable:  
Firma de TEV Ltd. designado como  
"persona responsable":  
(A C HAMMERSLEY)  
Position of Signatory:  
Fonction du signataire:  
Cargo del firmante:  
Functie van gemachtigde  
Position desUnterschreibenden:  
MANUFACTURING DIRECTOR  
DIRECTEUR DE FABRICATION  
DIRECTOR FABRICACIÓN  
PRODUKTIE COÖRDINATOR  
PRODUKTIONS DIREKTOR  
06617645-02  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
TECHNICAL FEATURES  
Frame  
All QLAC unit enclosures are manufactured from hot-galvanised sheet steel, painted with polyurethane  
powder enamel and stoved at 180°C to provide a durable, corrosion resistant finish. The frame is self-  
supporting with removable panels. All screws and rivets are made from stainless steel. The paint colour is  
RAL 7035.  
Refrigerant circuit  
Refrigerant is R407C. The refrigerant circuit is assembled using quality brand components and in  
accordance with ISO 97/23 concerning welding procedures. Model sizes 140 and upwards have multiple  
refrigerant circuits. Each refrigerant circuit is totally independent of the other. Failure of one circuit does not  
influence the other circuit. The refrigerant circuit includes:  
Liquid line manual shut-off valve  
Sight glass  
Filter drier  
Thermal expansion valve with external equalizer  
Electronic expansion valve with control to optimise efficiency in part load conditions (option)  
Reversing valve (heat pump version only)  
Non return valve (for heat pump version only)  
Liquid receiver (for heat pump version only)  
Schraeder valves for maintenance and control  
Pressure safety device (according to PED requirements)  
Compressors  
Scroll compressors are used, each fitted with a crankcase heater and provided with thermal overload  
protection via a klixon embedded in the motor winding. Compressors are mounted in a separate chamber in  
order to be separated from the air stream and to enable maintenance to be performed whilst the unit is still  
operating. The crankcase heater is always powered when the compressors are in stand-by. All compressors  
are in tandem configuration. This creates higher efficiencies uring part load conditions compared to units  
with independant refrigeration circuits per compressor.  
Condensers  
Condensers are made of copper tubes and aluminium fins. The diameter of the copper tubes is 3/8” and the  
thickness of the aluminium fins is 0.1 mm. Tubes are mechanically expanded into the aluminium fins to  
maximise heat transfer. The geometry of these condensers guarantees a low air side pressure drop and  
allows the use of slow running (and low noise) fans. The condensers can be protected by a metallic filter  
(option).  
Fans  
Fans are axial type with aerofoil blades. They are statically and dynamically balanced and supplied complete  
with safety fan guard that complies with the requirements of EN 294. They are mounted on the unit frame  
using rubber anti-vibration mounts. The electric motors are 6 pole (approx. 900 rpm) in the low noise version  
and 8 pole (approx. 750 rpm) in the extra low noise version. The fans are directly driven and are fitted with  
integral overload protection. Motors have moisture protection to IP 54.  
06617645-02  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Evaporators  
The plate evaporators are made of 316 stainless steel, braze-welded. Unit sizes 040 to size 130 have a  
single water side circuit. From unit size 140 upwards, the circuits are double “cross flow” type. The use of  
these types of evaporator allows a significant reduction of the refrigerant charge for the unit compared to  
traditional shell-in-tube evaporators and increases the efficiency of the refrigerant cycle during part load  
operation. The evaporators are factory insulated with flexible close-cell insulation and can be fitted with an  
antifreeze heater (optional). Each evaporator is provided with a temperature sensor as antifreeze protection.  
Hydraulic circuit (K versions only)  
QLAC chillers can be supplied with an optional built in hydraulic kit that includes:  
Water tank: various capacities (depending on the size of the unit), factory insulated with flexible close-cell  
material and ready for installation of an antifreeze kit (option). The water tank is installed on the supplied  
water side (7°C) in order to minimize fluctuations in the water temperature caused by cycling of the  
compressors. By installing on the supply side, the supply water temperature can be maintained for some  
time after the compressors turn off, a situation that cannot be achieved if the water tank is installed on the  
return water side (12°C).  
Water pump: centrifugal type, is available in single (K1) or double configuration (K2). In the K2 version, one  
pump is running and one pump is in stand-by. The change over can be manual (by a manual switch installed  
in the electric box) or automatically controlled by the microprocessor (option). The expansion vessel, safety  
valve and manual valves with fittings are sited in the hydraulic circuit.  
Electrics enclosure  
Access to the electrics enclosure is achieved by switching the mains isolator to "OFF" and removing the  
front cover.The electrics conform to electromagnetic compatibility norms CEE 73/23 and 89/336. Moisture  
protection is IP55.  
All QLAC units have installed, as standard, a compressor sequence relay, which disables compressor  
operation if the power supply phase sequence is incorrect (scroll compressors can be damaged if they  
operate in reverse). The following components are also installed as standard:  
Mains switch,  
Compressor fuses  
Compressor contactors  
Magnetic-thermal switches (MCB's) for protection of pumps and fans  
Control circuit automatic breakers  
Fan contactors, pump contactors.  
The terminal board is supplied with volt free contacts for remote ON-OFF, Heat / Cool change over (heat  
pumps only) and general alarms.  
Microprocessors  
QLAC units are supplied with microprocessor controls as standard. The specific controller used depends  
upon the unit size, number of features and use of optional features e.g. electronic expansion valves.The  
microprocessor controls the following basic functions:  
regulation of the water temperature  
antifreeze protection  
compressor timing  
compressor automatic starting sequence  
alarm reset  
volt free contact for remote common alarm  
alarms and leds.  
Any microprocessor can, on request, be connected to a BMS system for remote control and management.  
Typically, solutions can be found for MODBUS, LONWORKS, BACNET or TREND protocols.  
Control and protection devices  
All units are supplied with the following control and protection devices:  
Return water temperature sensor, installed on the return water line from the plant (12°C)  
Antifreeze protection sensor installed on the outlet water temperature (7°C)  
High pressure switch with manual reset  
Low pressure switch with automatic reset  
High pressure safety valve  
Compressor thermal overload protection  
Fan thermal overload protection  
Flow switch. (std versions supplied loose, K versions factory fitted)  
06617645-02  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
OTHER VERSIONS  
The following versions all incorporate energy efficiency features that make a valuable contribution to  
enabling compliance with the European Energy Performance of Buildings Directive and the 2006  
amendments to Part L of the UK Building Regulations.  
Heat pump version (HP)  
Heat pump versions are provided with a 4-way reversing valve and can produce hot water up to 45-50°C.  
They are always supplied with a second thermostatic valve and a liquid receiver to optimise the efficiency of  
the refrigerant cycle in heating and in cooling. The microprocessor is set for automatic defrost (for operation  
in severe ambient conditions) and for Heat/Cool change over by digital input.  
Free cooling version (FC)  
The Free Cooling option is a system designed to give important energy savings, when the cooling system is  
operating continuously and when ambients are low. Free cooling units use low temperature ambient air to  
cool down the water in the system. In some situations, chilled water can be produced without any  
mechanical refrigeration (compressors) with consequent large reduction of power consumption. The Free  
Cooling system comprises:  
Free cooling coil:  
Heat exchanger made of copper tubes and aluminium fins, with bleed  
valves.  
Microprocessor control:  
3 way valve:  
The “heart” of the system; it allows correct control of all parameters, leading  
to high efficiencies over a range of ambient conditions.  
An ON/OFF 3 way valve that opens/closes the free cooling circuit,  
depending on the signal coming from the microprocessor control.  
Head pressure control:  
Maintains the correct condensing pressure in the refrigerant circuit when  
ambient temperatures are low. In Free Cooling systems, this effect is  
achieved by partially closing refrigerant circuits in the condensing coil with  
solenoid valves: this reduces the heat transfer capacity and maintains a  
suitable condensing pressure.  
Heat Recovery Version  
A version that includes heat recovery by the addition of a de-superheater heat exchanger located between  
the compressor and condenser, is also available. This de-superheater can be fitted to both chiller and heat  
pump versions, however, in the heat pump it must be used only when in cooling mode. In heating mode the  
water circuit must be isolated. The de-superheater is capable of generating 50°C hot water for domestic use  
(washing etc) and can recover up to 25% of the energy removed in cooling by this manner. Such units make  
a valuable contribution to energy efficiency.  
06617645-02  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
WATER CHILLERS AND HEAT PUMPS  
QLAC / LS (Low noise version)  
TECHNICAL DATA  
MOD.  
040  
045  
050  
060  
070  
080  
090  
110  
Refrigerant  
R407C R407C R407C R407C R407C R407C R407C R407C  
Cooling capacity  
kW  
kW  
l/h  
37  
45,0  
15,1  
7910  
32,4  
52,0  
17,2  
58,0  
19,3  
64,0  
21,5  
78,0  
25,8  
90,0  
29,9  
104,0  
33,9  
Compressor input power  
Water flow rate  
12,6  
6490  
26,2  
9290 10320 11520 13590 15650 18400  
Water pressure drop  
KPa  
31,5  
23,3  
30,1  
30,4  
27,6  
26,5  
Heating capacity  
kW  
kW  
l/h  
38,5  
12,9  
6630  
28,5  
47,0  
15,2  
8085  
33,8  
55,0  
17,3  
62,0  
19,5  
68,0  
21,7  
83,0  
26,4  
95,0  
30,3  
107,0  
34,2  
Compressor input power  
Water flow rate  
9460 10665 11695 14275 16340 18400  
Water pressure drop  
kPa  
32,6  
24,8  
31,0  
33,5  
30,0  
26,5  
Total input current (K version)  
Total peak current  
A
32,4  
36  
37,4  
40,1  
42,8  
52,6  
62,0  
67,5  
A
A
121,4 148,4 154,4 194,4 194,0 235,4 265,1 275,1  
39,4 45,4 49,4 54,4 59,4 69,4 81,1 91,1  
400/3/50  
Maximum input current  
Power suppy  
V/Ph/Hz  
Airflow  
Fans  
m³/h 10800 10800 18800 18800 18000 17280 28080 27000  
n° x kW 2 x 0,37 2 x 0,37 2 x 0,69 2 x 0,69 2 x 0,69 2 x 0,69 3 x 0,69 3 x 0,69  
type  
n°  
Scroll  
Compressors  
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
Refrigerant circuits  
Control steps  
n°  
n°  
Sound power level (1)  
Sound pressure level (2)  
dB(A)  
dB(A)  
77  
49  
77  
49  
79  
51  
79  
51  
80  
52  
80  
52  
82  
54  
82,5  
54,5  
Water pump (option)  
kW  
1,1  
2,9  
165  
180  
18  
1,1  
2,9  
160  
180  
18  
1,1  
2,9  
141  
300  
18  
1,1  
2,9  
1,1  
2,9  
110  
300  
18  
1,5  
4,3  
150  
300  
18  
1,5  
4,3  
130  
530  
18  
2,2  
5,3  
150  
530  
18  
Water pump input current  
Pump available pressure (option)  
Water tank capacity (option)  
Expansion vessel (option)  
A
kPa  
125  
300  
18  
l
l
Length  
mm  
mm  
mm  
kg  
1870  
850  
1870  
850  
2608  
1105  
1759  
710  
2608  
1105  
1759  
725  
2608  
1105  
1759  
760  
2608  
1105  
1759  
810  
3608  
1105  
1759  
1070  
1280  
3608  
1105  
1759  
1150  
1360  
Width  
Height  
1406  
570  
1406  
590  
Weight (Standard configuration)  
Weight (with hydraulic kit)  
kg  
730  
750  
880  
895  
930  
980  
Performances are rated at:  
Cooling: ambient air temperature 35 °C; evaporator water temperature in/out 12°C / 7 °C.  
Heating: ambient air temperature 8.3 °C db, 6.1 °C wb ; condenser water temperature in/out 40°C / 45 °C.  
(1): Sound power level according to ISO 3746.  
(2): Sound pressure level measured at 10m from the unit in free field conditions: direction factor Q=2 (according to ISO 3746).  
06617645-02  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
WATER CHILLERS AND HEAT PUMPS  
QLAC / LS (Low noise version)  
TECHNICAL DATA  
MOD.  
120  
130  
140  
160  
190  
210  
240  
260  
Refrigerant  
R407C R407C R407C R407C R407C R407C R407C R407C  
Cooling capacity  
kW  
kW  
l/h  
115,5  
38  
128  
142  
156  
181  
206,1  
67,8  
232  
76  
256  
Compressor input power  
Water flow rate  
42,1  
47,3  
51,7  
59,7  
84,2  
20640 22190 24600 27180 31990 36290 41450 45240  
Water pressure drop  
kPa  
29,4  
30,0  
30,8  
36,0  
39,6  
42,7  
49,0  
51,2  
Heating capacity  
kW  
kW  
l/h  
120  
132  
150  
165  
189  
217  
242  
267  
Compressor input power  
Water flow rate  
38,5  
42,9  
48,1  
52,8  
60,6  
68,4  
77,1  
85,8  
20640 22700 25800 28380 32510 37320 41620 45920  
Water pressure drop  
kPa  
29,4  
76,4  
31,3  
85,5  
33,8  
39,2  
40,9  
45,1  
49,4  
52,7  
Total input current (K version)  
Total peak current  
A
96,3  
290  
104,7 126,6 144,0 160,2 178,4  
304 351 369 431 453  
A
A
322,1 333,1  
Maximum input current  
Power supply  
102,1 113,1 119,9 138,3 167,6 185,6 211,6 233,6  
400/3/50  
V/Ph/Hz  
Airflow  
Fans  
m°/h 25920 25920 36000 34920 55800 55800 58800 58800  
n° x kW 3 x 0,69 3 x 0,69 4 x 0,69 4 x 0,69 3 x 2,0 3 x 2,0 4 x 2,0 4 x 2,0  
type  
n°  
Scroll  
Compressors  
2
1
2
2
1
2
4
2
4
4
2
4
4
2
4
4
2
4
4
2
4
4
2
4
Refrigerant circuits  
Control steps  
n°  
n°  
Sound power level (1)  
Sound pressure level (2)  
dB(A)  
dB(A)  
82,9  
54,9  
83,1  
55,1  
83,5  
55,5  
84  
56  
86  
58  
86  
58  
89  
61  
89  
61  
Water pump (option)  
kW  
2,2  
5,3  
120  
530  
18  
2,2  
5,3  
130  
530  
18  
2,2  
5,3  
105  
530  
18  
3,0  
8,5  
3,0  
8,5  
140  
670  
18  
3,0  
8,5  
110  
670  
18  
4,0  
9,9  
170  
670  
18  
4,0  
9,9  
155  
670  
18  
Water pump input current  
Pump available pressure (option)  
Water tank capacity (option)  
Expansion vessel (option)  
A
kPa  
180  
670  
18  
l
l
mm  
mm  
mm  
kg  
3608  
1105  
1759  
1200  
1410  
3608  
1105  
1759  
1230  
1440  
4108  
1105  
2179  
1650  
1860  
4108  
1105  
2179  
1700  
2000  
4708  
1105  
2262  
1960  
2260  
4708  
1105  
2262  
2050  
2350  
4708  
1105  
2262  
2160  
2460  
4708  
1105  
2262  
2480  
2780  
Length  
Width  
Height  
Weight (Standard configuration)  
Weight (with hydraulic kit)  
kg  
Performances are rated at:  
Cooling: ambient air temperature 35 °C; evaporator water temperature in/out 12°C / 7 °C.  
Heating: ambient air temperature 8.3 °C db, 6.1 °C wb ; condenser water temperature in/out 40°C / 45 °C.  
(1): Sound power level according to ISO 3746.  
(2): Sound pressure level measured at 10m from the unit in free field conditions: direction factor Q=2 (according to ISO 3746).  
06617645-02  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
WATER CHILLERS AND HEAT PUMPS  
QLAC / LS (Low noise version)  
TECHNICAL DATA  
MOD.  
300  
320  
380  
430  
500  
Refrigerant  
R407C R407C R407C R407C R407C  
Cooling capacity  
kW  
kW  
l/h  
290  
321  
383  
432  
481  
Compressor input power  
Water flow rate  
92,4  
100,6 126,4 138,7 150,9  
49880 55200 65800 74300 82700  
Water pressure drop  
kPa  
34  
39  
32  
38  
44  
Free cooling capacity  
input power  
kW  
kW  
l/h  
185  
12  
185  
12  
235  
16  
245  
16  
240  
16  
Water flow rate  
49880 55200 65800 74300 82700  
Water pressure drop  
kPa  
107  
121  
113  
121  
141  
Total input current (K version)  
Total peak current  
A
201,4  
510  
220  
534  
279,2 301,7 324,2  
A
A
582  
641  
672,5  
425  
Maximum input current  
Power supply  
262,6 287,2  
362  
393,5  
V/Ph/Hz  
400/3/50  
Airflow  
Fans  
m°/h 89000 88500 119000 118000 118000  
n° x kW 6x2  
6x2  
8x2  
8x2  
8x2  
type  
Scroll  
Compressors  
n°  
n°  
n°  
4
2
4
4
2
4
6
2
6
6
2
6
6
2
6
Refrigerant circuits  
Control steps  
Sound power level (1)  
Sound pressure level (2)  
dB(A)  
dB(A)  
90  
62  
90  
62  
91  
63  
91  
63  
91  
63  
Water pump (option)  
kW  
4
5,5  
172  
670  
25  
7,5  
210  
670  
50  
7,5  
190  
670  
50  
7,5  
160  
670  
50  
Pump available pressure (option)  
Water tank capacity (option)  
Expansion vessel (option)  
kPa  
160  
670  
25  
l
l
mm  
mm  
mm  
kg  
4108  
2201  
2262  
2750  
3150  
4108  
2201  
2262  
2800  
3220  
4708  
2201  
2262  
3100  
3550  
4708  
2201  
2262  
3150  
3610  
4708  
2201  
2262  
3210  
3690  
Length  
Width  
Height  
Weight (Standard configuration)  
Weight (with hydraulic kit)  
kg  
Performances are rated at:  
Cooling: ambient air temperature 35 °C; evaporator water temperature in/out 12°C / 7 °C.  
Free cooling: ambient air temperature 2 °C; water inlet temperature 15°C, glycol 20%, nominal waterflow, compressors switched off  
(1): Sound power level according to ISO 3746.  
(2): Sound pressure level measured at 10m from the unit in free field conditions: direction factor Q=2 (according to ISO 3746).  
06617645-02  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
WATER CHILLERS AND HEAT PUMPS  
QLAC / XL (Extra Low noise version)  
TECHNICAL DATA  
MOD.  
040  
045  
050  
060  
070  
080  
090  
110  
Refrigerant  
R407C R407C R407C R407C R407C R407C  
Cooling capacity  
kW  
kW  
l/h  
52  
58  
64  
78  
90  
104  
### ###  
Compressor input power  
Water flow rate  
17,2  
19,3  
21,5  
25,8  
29,9  
33,9  
9290 10320 11520 13590 15650 18400  
Water pressure drop  
KPa  
31,5  
23,3  
30,1  
30,4  
27,6  
26,5  
Heating capacity  
kW  
kW  
l/h  
55,0  
17,3  
62,0  
19,5  
68,0  
21,7  
83,0  
26,4  
95,0  
30,3  
107,0  
34,2  
Compressor input power  
Water flow rate  
9460 10665 11695 14275 16340 18400  
Water pressure drop  
kPa  
32,6  
24,8  
31,0  
33,5  
30,0  
26,5  
Total input current (K version)  
Total peak current  
A
37,4  
40,1  
42,8  
194  
52,6  
62  
67,5  
A
A
154,4 194,4  
49,4 54,4  
235,4 265,1 275,1  
69,4 81,1 91,1  
Maximum input current  
Power suppy  
59,4  
V/Ph/Hz  
400/3/50  
Airflow  
Fans  
m³/h  
24000 24000 24000 23600 35000 35000  
2 x 1.23 2 x 1.23 2 x 1.23 2 x 1.23 3 x 1.23 3 x 1.23  
n° x kW  
type  
n°  
Scroll  
Compressors  
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
Refrigerant circuits  
Control steps  
n°  
n°  
Sound power level (1)  
Sound pressure level (2)  
dB(A)  
dB(A)  
76  
48  
76  
48  
78  
50  
78  
50  
79,5  
51,5  
79,9  
51,9  
Water pump (option)  
kW  
1,1  
141  
300  
18  
1,1  
125  
300  
18  
1,1  
110  
300  
18  
1,5  
150  
300  
18  
1,5  
130  
530  
18  
2,2  
150  
530  
18  
Pump available pressure (option)  
Water tank capacity (option)  
Expansion vessel (option)  
kPa  
l
l
Length  
mm  
mm  
mm  
kg  
2608  
1105  
1842  
710  
2608  
1105  
1842  
725  
2608  
1105  
1842  
760  
2608  
1105  
1842  
810  
3608  
1105  
1842  
1070  
1280  
3608  
1105  
1842  
1150  
1360  
Width  
Height  
Weight (Standard configuration)  
Weight (with hydraulic kit)  
kg  
880  
895  
930  
980  
# # # XL Models in these sizes are available as a special unit. Contact QUARTZ technical department for details.  
Performances are rated at:  
Cooling: ambient air temperature 35 °C; evaporator water temperature in/out 12°C / 7 °C.  
Heating: ambient air temperature 8.3 °C db, 6.1 °C wb ; condenser water temperature in/out 40°C / 45 °C.  
(1): Sound power level according to ISO 3746.  
(2): Sound pressure level measured at 10m from the unit in free field conditions: direction factor Q=2 (according to ISO 3746).  
06617645-02  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WATER CHILLERS AND HEAT PUMPS  
QLAC / XL (Extra Low noise version)  
TECHNICAL DATA  
MOD.  
120  
130  
140  
160  
190  
210  
240  
260  
Refrigerant  
R407C R407C R407C R407C R407C R407C  
Cooling capacity  
kW  
kW  
l/h  
115,5  
38  
128  
142  
156  
181  
206,1  
67,8  
### ###  
Compressor input power  
Water flow rate  
42,1  
47,3  
51,7  
59,7  
20640 22190 24600 27180 31990 36290  
Water pressure drop  
kPa  
29,4  
30,0  
30,8  
36,0  
39,6  
42,7  
Heating capacity  
kW  
kW  
l/h  
120  
132  
150  
165  
189  
217  
Compressor input power  
Water flow rate  
38,5  
42,9  
48,1  
52,8  
60,6  
68,4  
20640 22700 25800 28380 32510 37320  
Water pressure drop  
kPa  
29,4  
76,4  
31,3  
85,5  
33,8  
39,2  
40,9  
45,1  
Total input current (K version)  
Total peak current  
A
96,3  
290  
104,7 126,6  
304 351  
144  
369  
A
A
322,1 333,1  
Maximum input current  
Power supply  
102,1 113,1 119,9 138,3 167,6 185,6  
400/3/50  
V/Ph/Hz  
Airflow  
Fans  
m°/h 33000 33000 33000 33000 64000 62000  
n° x kW 3 x 1.23 3 x 1.23 3 x 1.23 3 x 1.23 4 x 1,25 4 x 1,25  
type  
n°  
Scroll  
Compressors  
2
1
2
2
1
2
4
2
4
4
2
4
4
2
4
4
2
4
Refrigerant circuits  
Control steps  
n°  
n°  
Sound power level (1)  
Sound pressure level (2)  
dB(A)  
dB(A)  
80,1  
52,1  
80,5  
52,5  
81  
53  
81,3  
53,3  
84  
58  
84  
58  
Water pump (option)  
kW  
2,2  
120  
530  
18  
2,2  
130  
530  
18  
2,2  
105  
530  
18  
3,0  
180  
670  
18  
3,0  
140  
670  
18  
3,0  
110  
670  
18  
Pump available pressure (option)  
Water tank capacity (option)  
Expansion vessel (option)  
kPa  
l
l
mm  
mm  
mm  
kg  
3608  
1105  
1842  
1200  
1410  
3608  
1105  
1842  
1230  
1440  
4108  
1105  
2262  
1650  
1860  
4108  
1105  
2262  
1700  
2000  
4708  
1105  
2262  
1960  
2260  
4708  
1105  
2262  
2050  
2350  
Length  
Width  
Height  
Weight (Standard configuration)  
Weight (with hydraulic kit)  
kg  
# # # XL Models in these sizes are available as a special unit. Contact QUARTZ technical department for details.  
Performances are rated at:  
Cooling: ambient air temperature 35 °C; evaporator water temperature in/out 12°C / 7 °C.  
Heating: ambient air temperature 8.3 °C db, 6.1 °C wb ; condenser water temperature in/out 40°C / 45 °C.  
(1): Sound power level according to ISO 3746.  
(2): Sound pressure level measured at 10m from the unit in free field conditions: direction factor Q=2 (according to ISO 3746).  
06617645-02  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
QLAC / LS (LOW NOISE VERSION)  
COOLING CAPACITIES AND COMPRESSOR INPUT POWER  
PF (kW)  
TA (°C)  
PA (kW)  
TA (°C)  
30 35  
MOD.  
TU (°C)  
20  
25  
30  
35  
40  
---  
---  
---  
---  
45  
---  
---  
---  
---  
---  
---  
20  
25  
40  
---  
---  
---  
---  
45  
---  
---  
---  
---  
---  
---  
-5  
-3  
-1  
1
26,64 24,98 23,36 21,79  
29,27 27,48 25,74 24,04  
32,07 30,15 28,28 26,44  
35,05 33,00 30,98 29,00  
9,39  
9,36  
9,32  
9,28  
9,24  
9,21  
9,19  
9,19  
9,21  
9,26  
9,34  
10,50 11,71 13,02  
10,50 11,76 13,13  
10,48 11,77 13,21  
10,44 11,77 13,25  
3
38,23 36,02 33,85 31,73 29,65  
41,60 39,24 36,91 34,63 32,39  
10,41 11,75 13,27 14,94  
10,36 11,72 13,26 14,98  
5
040  
7
45,18 42,66 40,17 37,71 35,31 32,95  
48,97 46,28 43,62 40,99 38,41 35,87  
52,99 50,12 47,28 44,48 41,71 38,98  
57,24 54,19 51,16 48,17 45,21 42,29  
61,74 58,50 55,27 52,08 48,92 45,80  
10,33 11,68 13,24 15,00 16,93  
10,30 11,64 13,21 14,99 16,97  
10,28 11,60 13,17 14,97 16,98  
10,28 11,57 13,13 14,93 16,97  
10,30 11,56 13,09 14,90 16,95  
9
11  
13  
15  
-5  
-3  
-1  
1
33,41 31,45 29,48 27,48  
36,45 34,36 32,24 30,11  
39,69 37,45 35,19 32,90  
43,13 40,75 38,33 35,89  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
11,23 12,52 13,96 15,56  
11,22 12,53 13,99 15,60  
11,21 12,53 14,01 15,64  
11,19 12,53 14,02 15,67  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
3
46,80 44,25 41,67 39,06 36,42  
50,69 47,98 45,23 42,44 39,63  
11,18 12,52 14,02 15,69 17,54  
11,16 12,51 14,03 15,71 17,58  
5
045  
050  
060  
7
54,83 51,94 49,01 46,00 43,04 40,00 11,14 12,50 14,02 15,72 17,61 19,70  
59,21 56,14 53,02 49,86 46,66 43,43 11,12 12,48 14,02 15,73 17,63 19,74  
63,85 60,59 57,27 53,91 50,51 47,07 11,09 12,47 14,01 15,73 17,65 19,78  
68,77 65,30 61,78 58,21 54,60 50,95 11,07 12,45 14,00 15,73 17,66 19,80  
73,96 70,28 66,55 62,77 58,94 55,06 11,05 12,43 13,98 15,73 17,67 19,83  
9
11  
13  
15  
-5  
-3  
-1  
1
39,58 37,29 34,94 32,53  
43,08 40,64 38,14 35,57  
46,80 44,21 41,54 38,82  
50,76 48,00 45,17 42,27  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
12,52 13,96 15,50 17,15  
12,50 13,98 15,58 17,30  
12,47 13,98 15,63 17,41  
12,43 13,97 15,66 17,49  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
3
54,98 52,04 49,03 45,95 42,79  
59,45 56,33 53,13 49,86 46,50  
12,38 13,94 15,66 17,54 19,58  
12,34 13,90 15,64 17,57 19,66  
5
7
64,19 60,88 57,49 54,00 50,46 46,82 12,29 13,85 15,62 17,57 19,71 22,03  
69,22 65,71 62,12 58,43 54,66 50,80 12,25 13,81 15,58 17,56 19,74 22,11  
74,55 70,83 67,02 63,11 59,12 55,04 12,22 13,77 15,54 17,53 19,74 22,17  
80,19 76,25 72,21 68,08 63,85 59,53 12,21 13,73 15,50 17,50 19,74 22,20  
86,14 81,97 77,70 73,34 68,87 64,31 12,22 13,70 15,46 17,46 19,71 22,21  
9
11  
13  
15  
-5  
-3  
-1  
1
44,18 41,55 38,86 36,12  
48,09 45,29 42,42 39,49  
52,26 49,27 46,22 43,09  
56,69 53,51 50,26 46,93  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
14,46 16,14 17,97 19,95  
14,47 16,18 18,07 20,12  
14,46 16,20 18,13 20,25  
14,45 16,21 18,18 20,35  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
3
61,41 58,02 54,56 51,02 47,40  
66,42 62,82 59,14 55,37 51,52  
14,43 16,21 18,21 20,42 22,85  
14,42 16,20 18,22 20,47 22,95  
5
7
71,73 67,91 64,00 60,00 55,91 51,74 14,40 16,18 18,21 20,49 23,02 25,78  
77,37 73,31 69,16 64,91 60,58 56,15 14,40 16,17 18,21 20,51 23,07 25,88  
83,34 79,04 74,63 70,13 65,54 60,85 14,41 16,16 18,20 20,51 23,10 25,96  
89,66 85,10 80,43 75,67 70,80 65,84 14,44 16,17 18,19 20,50 23,11 26,01  
96,34 91,51 86,57 81,53 76,39 71,14 14,50 16,19 18,19 20,50 23,12 26,04  
9
11  
13  
15  
TU: Outlet water temperature (°C)  
TA: Ambient temperature (°C)  
PA: Compressors input power (kW)  
PF: Cooling capacity (kW)  
06617645-02  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
QLAC / LS (LOW NOISE VERSION)  
COOLING CAPACITIES AND COMPRESSOR INPUT POWER  
PF (kW)  
TA (°C)  
PA (kW)  
TA (°C)  
30 35  
MOD.  
TU (°C)  
20  
25  
30  
35  
40  
---  
---  
---  
---  
45  
---  
---  
---  
---  
---  
---  
20  
25  
40  
---  
---  
---  
---  
45  
---  
---  
---  
---  
---  
---  
-5  
-3  
-1  
1
49,33 46,44 43,48 40,47  
53,68 50,59 47,43 44,21  
58,31 55,01 51,64 48,21  
63,23 59,72 56,13 52,47  
15,63 17,47 19,51 21,77  
15,65 17,51 19,60 21,92  
15,66 17,54 19,66 22,03  
15,66 17,56 19,71 22,12  
3
68,47 64,73 60,91 57,00 53,02  
74,04 70,06 65,99 61,83 57,59  
15,67 17,57 19,74 22,18 24,90  
15,69 17,58 19,76 22,23 24,99  
5
070  
7
79,95 75,72 71,39 67,00 62,46 57,87 15,72 17,59 19,77 22,26 25,05 28,15  
86,21 81,72 77,12 72,43 67,64 62,76 15,76 17,62 19,79 22,28 25,10 28,24  
92,85 88,08 83,20 78,22 73,14 67,97 15,83 17,65 19,81 22,30 25,14 28,31  
99,87 94,81 89,64 84,37 78,99 73,50 15,92 17,70 19,84 22,32 25,16 28,36  
107,3 101,9 96,46 90,88 85,18 79,38 16,05 17,78 19,88 22,35 25,19 28,40  
9
11  
13  
15  
-5  
-3  
-1  
1
58,51 55,07 51,54 47,94  
63,71 60,03 56,27 52,42  
69,24 65,32 61,31 57,21  
75,12 70,95 66,68 62,30  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
19,61 21,99 24,54 27,22  
19,57 22,02 24,67 27,51  
19,52 22,00 24,75 27,71  
19,46 21,96 24,76 27,83  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
3
81,38 76,94 72,39 67,73 62,97  
88,03 83,30 78,46 73,50 68,44  
19,40 21,90 24,75 27,89 31,30  
19,37 21,84 24,70 27,90 31,42  
5
080  
090  
110  
7
95,08 90,06 84,91 79,00 74,26 68,76 19,37 21,79 24,64 27,88 31,47 35,37  
102,5 97,22 91,75 86,16 80,45 74,61 19,41 21,76 24,58 27,83 31,47 35,47  
110,5 104,8 99,02 93,08 87,02 80,84 19,52 21,77 24,54 27,77 31,45 35,51  
118,8 112,8 106,7 100,4 94,00 87,45 19,70 21,83 24,52 27,72 31,40 35,51  
127,7 121,3 114,8 108,2 101,4 94,47 19,97 21,96 24,54 27,68 31,34 35,48  
9
11  
13  
15  
-5  
-3  
-1  
1
67,32 63,10 58,71 54,16  
73,37 68,89 64,23 59,41  
79,80 75,05 70,12 65,01  
86,64 81,61 76,39 70,98  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
22,38 25,09 28,16 31,62  
22,41 25,14 28,23 31,73  
22,44 25,18 28,30 31,83  
22,46 25,21 28,34 31,90  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
3
93,92 88,59 83,06 77,33 71,41  
101,6 96,00 90,15 84,10 77,84  
22,50 25,24 28,39 31,97 36,01  
22,54 25,27 28,43 32,02 36,09  
5
7
109,8 103,8 97,69 91,00 84,68 77,87 22,59 25,31 28,46 32,07 36,15 40,75  
118,5 112,2 105,6 98,92 91,95 84,76 22,66 25,37 28,51 32,11 36,21 40,84  
127,6 121,0 114,1 107,0 99,67 92,10 22,75 25,43 28,56 32,16 36,27 40,91  
137,4 130,3 123,1 115,6 107,8 99,88 22,86 25,51 28,62 32,21 36,32 40,97  
147,6 140,2 132,6 124,7 116,5 108,1 23,00 25,61 28,70 32,28 36,38 41,04  
9
11  
13  
15  
-5  
-3  
-1  
1
78,60 73,67 68,49 63,05  
85,65 80,44 74,96 69,23  
93,15 87,65 81,87 75,82  
101,1 95,32 89,22 82,84  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
24,07 26,92 30,28 34,24  
24,17 27,00 30,31 34,21  
24,28 27,10 30,38 34,23  
24,39 27,21 30,47 34,28  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
3
109,5 103,4 97,04 90,32 83,31  
118,5 112,1 105,3 98,27 90,89  
24,50 27,33 30,59 34,36 38,76  
24,61 27,46 30,71 34,47 38,83  
5
7
128,1 121,3 114,1 107,0 98,96 90,90 24,69 27,58 30,85 34,60 38,92 43,93  
138,1 131,0 123,5 115,6 107,5 99,06 24,76 27,70 30,99 34,74 39,05 44,01  
148,8 141,3 133,4 125,2 116,6 107,7 24,81 27,80 31,13 34,90 39,20 44,13  
160,1 152,2 143,9 135,2 126,2 116,9 24,82 27,88 31,26 35,05 39,36 44,28  
172,0 163,7 154,9 145,9 136,4 126,6 24,80 27,94 31,38 35,21 39,53 44,44  
9
11  
13  
15  
TU: Outlet water temperature (°C)  
TA: Ambient temperature (°C)  
PA: Compressors input power (kW)  
PF: Cooling capacity (kW)  
QLAC / LS (LOW NOISE VERSION)  
13  
06617645-02  
Download from Www.Somanuals.com. All Manuals Search And Download.  
COOLING CAPACITIES AND COMPRESSOR INPUT POWER  
PF (kW)  
TA (°C)  
PA (kW)  
TA (°C)  
30 35  
MOD.  
TU (°C)  
20  
25  
30  
35  
40  
---  
---  
---  
---  
45  
---  
---  
---  
---  
---  
---  
20  
25  
40  
---  
---  
---  
---  
45  
---  
---  
---  
---  
---  
---  
-5  
-3  
-1  
1
88,37 82,32 76,09 69,68  
96,55 90,15 83,54 76,75  
105,2 98,48 91,49 84,29  
114,5 107,3 99,94 92,33  
27,64 31,00 34,96 39,62  
27,75 31,07 34,98 39,56  
27,87 31,15 35,02 39,54  
28,00 31,26 35,08 39,55  
3
124,3 116,7 108,9 100,8 92,62  
134,8 126,8 118,5 109,9 101,2  
28,14 31,38 35,17 39,58 44,72  
28,28 31,51 35,27 39,65 44,73  
5
120  
7
145,9 137,4 128,6 120,0 110,4 100,9 28,43 31,66 35,39 39,73 44,76 50,57  
157,7 148,7 139,4 129,9 120,2 110,2 28,58 31,81 35,53 39,84 44,82 50,57  
170,1 160,6 150,9 140,8 130,5 120,0 28,72 31,96 35,67 39,96 44,91 50,60  
183,3 173,3 163,0 152,4 141,5 130,4 28,86 32,11 35,83 40,10 45,01 50,66  
197,2 186,6 175,8 164,6 153,2 141,5 29,00 32,26 35,98 40,25 45,14 50,75  
9
11  
13  
15  
-5  
-3  
-1  
1
95,43 88,46 81,36 74,17  
104,5 97,10 89,57 81,92  
114,1 106,3 98,31 90,19  
124,4 116,1 107,6 99,00  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
31,38 35,29 39,89 45,26  
31,48 35,34 39,88 45,17  
31,61 35,41 39,88 45,11  
31,74 35,50 39,92 45,08  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
3
135,4 126,5 117,5 108,3 99,10  
147,0 137,6 128,0 118,3 108,5  
31,90 35,61 39,97 45,06 50,98  
32,08 35,73 40,04 45,07 50,91  
5
130  
140  
160  
7
159,4 149,4 139,2 129,0 118,5 107,9 32,27 35,88 40,13 45,11 50,88 57,52  
172,5 161,9 151,1 140,2 129,2 118,0 32,48 36,05 40,25 45,16 50,87 57,44  
186,3 175,1 163,8 152,2 140,5 128,6 32,70 36,23 40,39 45,24 50,88 57,38  
201,0 189,2 177,1 164,9 152,5 140,0 32,95 36,44 40,55 45,35 50,92 57,34  
216,5 204,0 191,3 178,4 165,3 152,0 33,21 36,66 40,73 45,47 50,98 57,34  
9
11  
13  
15  
-5  
-3  
-1  
1
105,5 99,32 92,90 86,35  
114,9 108,2 101,4 94,42  
124,9 117,7 110,4 103,0  
135,5 127,9 120,1 112,1  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
35,77 40,04 44,70 49,71  
35,76 40,13 44,94 50,16  
35,71 40,15 45,09 50,50  
35,66 40,14 45,17 50,72  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
3
146,8 138,7 130,4 121,9 113,2  
158,7 150,1 141,3 132,3 123,1  
35,62 40,09 45,19 50,86 57,07  
35,59 40,04 45,17 50,93 57,29  
5
7
171,5 162,3 152,9 143,0 133,5 123,6 35,62 40,01 45,13 50,94 57,42 64,51  
185,0 175,2 165,3 155,1 144,7 134,1 35,70 40,00 45,08 50,93 57,48 64,71  
199,2 188,9 178,3 167,5 156,5 145,3 35,86 40,03 45,06 50,89 57,50 64,84  
214,4 203,4 192,2 180,8 169,1 157,2 36,12 40,14 45,06 50,86 57,48 64,90  
230,3 218,7 206,9 194,8 182,4 169,8 36,49 40,32 45,12 50,84 57,46 64,92  
9
11  
13  
15  
-5  
-3  
-1  
1
115,9 109,1 102,1 95,01  
126,2 118,9 111,5 103,9  
137,2 129,4 121,5 113,3  
148,9 140,6 132,1 123,4  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
39,22 43,97 49,07 54,44  
39,15 44,03 49,35 55,02  
39,04 44,00 49,49 55,41  
38,91 43,92 49,53 55,66  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
3
161,3 152,4 143,4 134,2 124,8  
174,4 165,1 155,5 145,6 135,6  
38,80 43,80 49,49 55,78 62,61  
38,73 43,68 49,40 55,81 62,83  
5
7
188,4 178,4 168,2 158,0 147,1 136,2 38,73 43,58 49,28 55,76 62,93 70,73  
203,2 192,6 181,8 170,7 159,4 147,8 38,83 43,53 49,16 55,66 62,95 70,93  
218,9 207,7 196,2 184,4 172,4 160,2 39,04 43,55 49,07 55,55 62,89 71,02  
235,5 223,6 211,4 199,0 186,3 173,3 39,40 43,66 49,04 55,44 62,79 71,02  
253,1 240,5 227,6 214,4 200,9 187,2 39,93 43,91 49,08 55,36 62,69 70,97  
9
11  
13  
15  
TU: Outlet water temperature (°C)  
TA: Ambient temperature (°C)  
PA: Compressors input power (kW)  
PF: Cooling capacity (kW)  
QLAC / LS (LOW NOISE VERSION)  
14  
06617645-02  
Download from Www.Somanuals.com. All Manuals Search And Download.  
COOLING CAPACITIES AND COMPRESSOR INPUT POWER  
PF (kW)  
TA (°C)  
PA (kW)  
TA (°C)  
30 35  
MOD.  
TU (°C)  
20  
25  
30  
35  
40  
---  
---  
---  
---  
45  
---  
---  
---  
---  
---  
---  
20  
25  
40  
---  
---  
---  
---  
45  
---  
---  
---  
---  
---  
---  
-5  
-3  
-1  
1
3
5
137,1 128,7 120,0 111,0  
149,3 140,5 131,2 121,7  
162,3 152,9 143,2 133,1  
176,2 166,2 155,9 145,2  
190,9 180,4 169,4 158,1 146,4  
206,5 195,4 183,8 171,8 159,4  
223,1 211,3 199,1 186,0 173,3 159,8 43,70 48,91 54,95 61,87 69,75 78,64  
240,6 228,2 215,3 201,9 188,1 173,8 43,85 49,02 55,03 61,96 69,86 78,78  
259,2 246,1 232,4 218,3 203,8 188,7 44,04 49,16 55,14 62,06 69,96 78,92  
278,9 265,0 250,6 235,7 220,4 204,6 44,29 49,34 55,28 62,17 70,07 79,04  
299,6 285,0 269,8 254,2 238,0 221,3 44,59 49,56 55,44 62,30 70,18 79,16  
156,5 146,1 135,1 123,7  
170,6 159,7 148,1 136,1  
185,8 174,2 162,0 149,3  
201,8 189,6 176,8 163,4  
43,27 48,48 54,40 61,08  
43,32 48,56 54,53 61,28  
43,37 48,63 54,63 61,44  
43,43 48,69 54,72 61,58  
43,49 48,75 54,80 61,69 69,49  
43,58 48,82 54,87 61,79 69,63  
190  
7
9
11  
13  
15  
-5  
-3  
-1  
1
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
50,88 57,06 64,35 72,97  
51,06 57,18 64,37 72,83  
51,27 57,35 64,45 72,79  
51,51 57,56 64,60 72,83  
51,74 57,80 64,80 72,95 82,44  
51,98 58,06 65,05 73,13 82,52  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
3
5
218,9 206,0 192,5 178,4 163,7  
237,0 223,5 209,2 194,3 178,9  
210  
240  
260  
7
9
256,3 241,9 227,0 211,0 195,1 178,2 52,20 58,33 65,32 73,37 82,67 93,43  
276,6 261,6 245,8 229,3 212,2 194,5 52,39 58,59 65,61 73,64 82,89 93,55  
298,2 282,3 265,7 248,5 230,5 211,9 52,54 58,83 65,90 73,95 83,16 93,74  
320,9 304,3 286,8 268,7 249,9 230,4 52,64 59,05 66,20 74,27 83,47 93,99  
344,9 327,4 309,2 290,1 270,4 249,9 52,68 59,23 66,47 74,60 83,81 94,30  
11  
13  
15  
-5  
-3  
-1  
1
3
5
7
9
11  
13  
15  
-5  
-3  
-1  
1
3
5
7
9
178,3 166,1 153,5 140,6  
194,8 181,9 168,5 154,8  
212,4 198,7 184,6 170,0  
231,1 216,6 201,6 186,3  
251,0 235,6 219,8 203,5 186,8  
272,1 255,8 239,1 221,9 204,3  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
55,28 62,00 69,93 79,23  
55,49 62,13 69,95 79,12  
55,73 62,31 70,03 79,08  
55,99 62,52 70,16 79,09  
56,27 62,76 70,33 79,17 89,44  
56,56 63,03 70,55 79,30 89,46  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
294,5 277,3 259,6 241,0 222,8 203,7 56,86 63,31 70,79 79,47 89,53 101,1  
318,2 300,1 281,4 262,2 242,5 222,4 57,16 63,61 71,06 79,68 89,65 101,1  
343,3 324,2 304,5 284,2 263,4 242,2 57,45 63,92 71,35 79,92 89,82 101,2  
369,9 349,7 328,9 307,5 285,6 263,2 57,73 64,22 71,65 80,20 90,03 101,3  
398,0 376,7 354,7 332,2 309,2 285,6 57,99 64,53 71,97 80,49 90,28 101,5  
194,3 180,1 165,6 151,0  
212,7 197,7 182,3 166,8  
232,4 216,4 200,1 183,6  
253,4 236,4 219,1 201,5  
275,7 257,6 239,3 220,6 201,7  
299,4 280,2 260,7 241,0 220,9  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
62,76 70,58 79,77 90,51  
62,97 70,68 79,75 90,35  
63,21 70,82 79,77 90,23  
63,49 70,99 79,83 90,16  
63,80 71,21 79,93 90,13 101,9  
64,15 71,47 80,08 90,15 101,8  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
324,5 304,2 283,6 263,0 241,3 219,8 64,53 71,76 80,27 90,22 101,7 115,0  
351,2 329,7 307,8 285,6 263,0 240,2 64,95 72,09 80,50 90,33 101,7 114,8  
379,4 356,6 333,5 310,0 286,1 262,0 65,41 72,47 80,78 90,49 101,7 114,7  
409,3 385,2 360,7 335,8 310,6 285,1 65,90 72,88 81,09 90,69 101,8 114,6  
440,9 415,4 389,5 363,3 336,6 309,6 66,42 73,33 81,45 90,95 101,9 114,6  
11  
13  
15  
TU: Outlet water temperature (°C)  
TA: Ambient temperature (°C)  
PA: Compressors input power (kW)  
PF: Cooling capacity (kW)  
QLAC / LS (LOW NOISE VERSION)  
15  
06617645-02  
Download from Www.Somanuals.com. All Manuals Search And Download.  
COOLING CAPACITIES AND COMPRESSOR INPUT POWER  
PF (kW)  
TA (°C)  
30  
PA (kW)  
MOD.  
TU (°C)  
TA (°C)  
20  
25  
35  
40  
20  
25  
30  
35  
40  
1
3
5
7
9
11  
13  
15  
1
3
5
7
9
11  
13  
15  
1
3
5
7
9
275.9 258.8 240.9 221.8 201.4  
299.9 281.7 262.8 242.7 221.4  
325.5 306.1 286.0 264.9 242.5  
352.7 332.1 310.7 288.4 264.9  
381.7 359.7 337.0 313.4 288.6  
412.6 389.0 364.8 339.8 313.7  
445.4 420.2 394.5 367.9 340.3  
480.3 453.4 425.9 397.8 368.6  
304.3 286.5 267.4 246.3 222.8  
330.8 311.9 291.8 269.9 245.7  
359.1 338.9 317.7 294.8 269.7  
389.3 367.7 345.1 321.1 294.9  
421.6 398.4 374.3 348.9 321.6  
456.1 431.1 405.4 378.5 349.8  
493.0 466.0 438.5 409.9 379.7  
532.3 503.3 473.8 443.4 411.5  
371.3 346.7 321.5 295.9 269.9  
403.6 377.4 350.6 323.4 295.7  
437.8 410.0 381.6 352.6 323.1  
474.2 444.6 414.4 383.7 352.3  
512.8 481.4 449.3 416.7 383.4  
553.6 520.3 486.4 451.7 416.4  
596.9 561.6 525.6 488.9 451.5  
642.5 605.2 567.1 528.2 488.6  
413.9 388.2 361.3 332.7 302.1  
449.9 422.6 394.2 364.1 332.1  
488.2 459.2 429.0 397.4 363.8  
65.7  
66.1  
66.5  
67.0  
67.6  
68.2  
68.9  
69.7  
71.3  
71.7  
72.2  
72.7  
73.4  
74.1  
74.9  
75.9  
90.0  
90.6  
91.3  
92.0  
92.8  
93.6  
94.5  
95.4  
98.5  
99.1  
99.8  
73.2  
73.5  
73.8  
74.2  
74.7  
75.2  
75.8  
76.4  
79.7  
80.0  
80.3  
80.7  
81.2  
81.7  
82.4  
83.1  
81.8  
82.1  
82.3  
82.7  
83.0  
83.4  
83.9  
84.4  
89.1  
89.4  
89.7  
90.0  
90.3  
90.7  
91.2  
91.7  
91.8  
92.0  
92.2  
92.4  
92.7  
93.0  
93.3  
93.7  
99.8  
100.1 112.3  
100.4 112.6  
100.6 112.8  
100.9 113.0  
101.2 113.3  
101.5 113.5  
101.9 113.8  
103.3  
103.5  
103.6  
103.8  
103.9  
104.1  
104.4  
104.6  
112.0  
300  
320  
380  
430  
500  
100.0 111.8 125.7 142.0  
100.5 112.2 125.9 142.0  
101.0 112.6 126.1 142.0  
101.6 113.0 126.4 142.1  
102.3 113.5 126.8 142.3  
103.0 114.1 127.2 142.5  
103.8 114.8 127.7 142.8  
104.6 115.5 128.3 143.2  
109.7 122.7 137.7 155.0  
110.2 123.1 138.0 155.2  
110.8 123.5 138.3 155.4  
11  
13  
15  
1
3
5
7
9
11  
13  
15  
1
3
5
7
9
529.1 498.1 466.1 432.6 397.4 100.6  
11.4  
124.0 138.7 155.6  
572.6 539.5 505.4 470.0 432.9 101.4 112.0 124.5 139.1 155.9  
618.9 583.5 547.3 509.7 470.6 102.4 112.8 125.1 139.5 156.2  
668.2 630.3 591.7 551.9 510.5 103.4 113.7 125.8 140.0 156.6  
720.5 680.0 638.9 596.6 552.9 104.6 114.6 126.5 140.6 157.0  
456.4 429.8 401.1 369.5 334.3 107.0 119.5 133.6 149.7 168.0  
496.2 467.9 437.7 404.9 368.5 107.6 120.0 134.1 150.1 168.4  
538.6 508.4 476.5 442.1 404.5 108.3 120.5 134.5 150.5 168.8  
584.0 551.6 517.7 481.6 442.4 109.1 121.1 135.0 150.9 169.2  
632.4 597.6 561.5 523.4 482.4 110.0 121.8 135.5 151.3 169.6  
684.2 646.7 608.1 567.8 524.7 111.1 122.6 136.1 151.8 169.9  
739.5 699.1 657.8 614.9 569.6 112.4 123.5 136.8 152.3 170.3  
798.5 754.9 710.7 665.1 617.2 113.8 124.6 137.6 152.9 170.7  
11  
13  
15  
TU: Evaporator Outlet water temperature (°C)  
TA: Ambient temperature (°C)  
PA: Compressors input power (kW)  
PF: Cooling capacity (kW)  
QLAC / HP / LS (LOW NOISE VERSION)  
06617645-02  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HEATING CAPACITIES AND COMPRESSOR INPUT POWER  
PC (kW)  
TU (°C)  
PA (kW)  
TU (°C)  
MOD.  
TA (°C)  
30  
35  
---  
40  
---  
45  
---  
50  
---  
55  
---  
30  
9,1  
35  
---  
40  
---  
45  
---  
50  
---  
55  
---  
-5  
0
5
25,1  
30,3  
36,2  
40,2  
43,0  
51,1  
60,5  
32,1  
37,9  
44,8  
49,4  
52,8  
62,1  
73,0  
37,3  
44,2  
52,1  
57,4  
61,2  
71,8  
84,1  
42,3  
50,0  
59,0  
65,0  
69,3  
81,4  
95,5  
46,7  
55,2  
65,1  
71,8  
76,6  
90,0  
29,8  
35,6  
39,4  
42,2  
49,8  
58,8  
---  
37,5  
44,1  
48,6  
51,8  
60,8  
71,2  
---  
43,6  
51,2  
56,4  
60,1  
70,2  
82,0  
---  
49,3  
58,0  
63,8  
68,0  
79,5  
93,0  
---  
---  
---  
---  
---  
---  
---  
40,7  
47,5  
55,2  
---  
---  
---  
---  
---  
---  
---  
---  
54,5  
---  
---  
---  
---  
---  
---  
65,2  
---  
---  
---  
---  
---  
---  
75,0  
---  
---  
---  
---  
---  
---  
84,9  
---  
---  
---  
---  
---  
---  
93,8  
---  
---  
---  
9,2  
9,2  
9,1  
9,1  
9,0  
9,0  
10,2  
10,3  
10,2  
10,2  
10,1  
10,0  
---  
12,2  
12,3  
12,3  
12,3  
12,2  
12,2  
---  
14,0  
14,0  
14,0  
14,0  
13,9  
13,8  
---  
15,4  
15,6  
15,7  
15,7  
15,6  
15,6  
---  
17,1  
17,3  
17,3  
17,3  
17,4  
17,4  
---  
20,8  
21,0  
21,0  
20,9  
20,8  
20,8  
---  
23,8  
24,0  
24,0  
24,1  
24,1  
24,3  
---  
26,8  
26,9  
27,0  
27,2  
27,5  
27,8  
---  
---  
---  
---  
---  
---  
14,5  
14,6  
14,6  
---  
---  
---  
---  
---  
---  
---  
---  
16,6  
---  
---  
---  
---  
---  
---  
19,3  
---  
---  
---  
---  
---  
---  
22,1  
---  
---  
---  
---  
---  
---  
25,0  
---  
---  
---  
---  
---  
---  
27,9  
---  
---  
---  
---  
---  
---  
33,8  
---  
---  
---  
---  
---  
---  
39,0  
---  
---  
---  
---  
---  
---  
44,1  
35,1  
38,8  
41,5  
48,8  
57,3  
---  
11,5  
11,5  
11,5  
11,4  
11,3  
---  
8
38,5  
41,0  
48,0  
56,1  
---  
12,9  
12,9  
12,9  
12,9  
---  
040  
10  
15  
20  
-5  
0
11,0  
11,0  
11,0  
11,0  
11,0  
10,9  
10,9  
12,3  
12,5  
12,5  
12,5  
12,5  
12,3  
12,2  
13,7  
13,9  
14,0  
14,0  
14,0  
13,9  
13,9  
15,1  
15,4  
15,5  
15,5  
15,5  
15,5  
15,6  
18,4  
18,7  
18,7  
18,6  
18,6  
18,5  
18,7  
21,1  
21,3  
21,4  
21,4  
21,5  
21,5  
21,7  
23,9  
23,9  
24,1  
24,2  
24,3  
24,6  
24,8  
---  
---  
---  
---  
---  
---  
5
8
43,5  
47,8  
50,9  
59,5  
69,5  
---  
13,7  
13,7  
13,7  
13,7  
13,7  
---  
47,0  
50,2  
58,4  
67,9  
---  
---  
15,3  
15,3  
15,4  
15,4  
---  
---  
045  
050  
060  
070  
080  
090  
110  
10  
15  
20  
-5  
0
49,6  
57,4  
66,5  
---  
---  
---  
17,1  
17,2  
17,2  
---  
---  
---  
---  
---  
---  
---  
---  
---  
5
8
50,4  
55,4  
59,0  
68,8  
80,1  
---  
15,6  
15,6  
15,6  
15,6  
15,6  
---  
55,0  
58,0  
67,4  
78,3  
---  
---  
17,4  
17,5  
17,6  
17,5  
---  
---  
10  
15  
20  
-5  
0
57,0  
66,2  
76,6  
---  
---  
---  
19,4  
19,7  
19,7  
---  
---  
---  
---  
---  
---  
---  
---  
---  
5
8
57,1  
62,7  
66,7  
77,8  
90,7  
---  
17,4  
17,5  
17,6  
17,6  
17,6  
---  
61,7  
65,6  
76,3  
88,6  
---  
---  
19,5  
19,6  
19,8  
19,8  
---  
---  
10  
15  
20  
-5  
0
64,6  
74,9  
86,7  
---  
---  
---  
21,9  
22,2  
22,3  
---  
---  
---  
54,5  
64,0  
70,4  
75,0  
87,8  
---  
---  
---  
---  
---  
---  
5
8
63,1  
69,2  
73,7  
85,9  
19,3  
19,4  
19,5  
19,5  
19,6  
---  
68,2  
72,5  
84,2  
97,8  
---  
---  
---  
82,8  
88,0  
---  
21,7  
21,8  
22,0  
22,0  
---  
---  
10  
15  
20  
-5  
0
71,5  
82,7  
95,7  
---  
---  
---  
24,4  
24,7  
24,8  
---  
---  
---  
105,6 102,8 100,2  
56,3  
66,8  
78,6  
86,6  
92,3  
---  
---  
---  
76,5  
83,9  
89,2  
65,9  
77,5  
85,2  
90,7  
---  
---  
---  
5
8
23,5  
23,6  
23,6  
23,5  
23,4  
---  
---  
86,8  
---  
---  
---  
26,4  
26,5  
26,6  
26,5  
---  
---  
10  
15  
20  
-5  
0
29,7  
30,0  
30,0  
---  
---  
---  
108,4 106,0 103,9 102,1 100,5  
127,3 124,0 121,0 118,3 116,0 113,9  
64,7  
76,5  
90,4  
99,8  
106,5 104,3 102,3 100,5  
125,4 122,4 119,6 117,1 114,8  
147,3 143,4 139,8 136,4 133,2 130,3  
73,4  
86,7  
102,7 100,6  
113,6 111,0 108,7 106,7  
121,4 118,6 115,9 113,5 111,5  
143,2 139,6 136,1 132,7 129,7  
168,2 163,9 159,5 155,2 151,1 147,4  
---  
---  
---  
87,4  
96,0  
---  
---  
---  
---  
---  
---  
---  
98,9  
---  
---  
---  
---  
---  
---  
75,5  
88,8  
97,8  
---  
---  
---  
5
8
26,9  
27,0  
27,0  
27,1  
27,2  
---  
94,5  
30,3  
30,4  
30,5  
30,6  
---  
---  
---  
34,2  
34,2  
34,5  
34,8  
---  
10  
15  
20  
-5  
0
5
8
10  
15  
20  
34,2  
34,4  
34,5  
---  
---  
---  
---  
---  
98,8  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
85,4  
---  
30,3  
30,3  
30,4  
30,7  
31,1  
---  
38,7  
38,8  
39,1  
TU: Outlet water temperature (°C)  
TA: Ambient temperature dry bulb (°C)  
PA: Compressors input power (kW)  
PH: Heating capacity (kW)  
06617645-02  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
QLAC / HP / LS (LOW NOISE VERSION)  
HEATING CAPACITIES AND COMPRESSOR INPUT POWER  
PC (kW)  
TU (°C)  
PA (kW)  
TU (°C)  
MOD.  
TA (°C)  
30  
82,2  
97,9  
35  
---  
96,1  
40  
---  
---  
45  
---  
---  
---  
50  
---  
---  
---  
---  
55  
---  
---  
---  
---  
---  
---  
30  
35  
---  
40  
---  
---  
34,1  
34,2  
34,2  
34,5  
34,8  
---  
45  
---  
---  
50  
---  
---  
---  
---  
43,7  
43,7  
43,8  
---  
---  
---  
55  
---  
---  
---  
---  
---  
---  
49,4  
---  
---  
---  
---  
---  
---  
54,7  
---  
---  
---  
---  
---  
---  
61,8  
---  
---  
---  
---  
---  
---  
67,7  
---  
---  
---  
---  
---  
---  
77,9  
---  
---  
---  
---  
---  
---  
88,1  
---  
---  
---  
---  
---  
---  
98,8  
---  
---  
---  
---  
---  
---  
-5  
0
5
26,8  
26,8  
27,0  
27,2  
27,3  
27,7  
28,1  
29,6  
29,8  
30,0  
30,2  
30,3  
30,8  
31,3  
33,5  
34,1  
34,2  
34,1  
34,1  
34,0  
34,3  
36,7  
37,4  
37,4  
37,3  
37,1  
37,0  
37,4  
42,3  
42,6  
42,8  
42,9  
42,9  
43,1  
43,5  
47,8  
47,8  
48,1  
48,5  
48,7  
49,2  
49,6  
53,5  
53,7  
54,1  
54,4  
54,7  
55,4  
56,1  
59,3  
59,5  
60,0  
60,4  
60,7  
61,6  
62,7  
30,2  
30,3  
30,4  
30,5  
30,8  
31,2  
---  
33,5  
33,6  
33,8  
33,9  
34,2  
34,6  
---  
37,9  
38,3  
38,3  
38,3  
38,2  
38,2  
---  
41,6  
42,0  
42,0  
41,9  
41,6  
41,6  
---  
47,6  
47,9  
48,0  
48,1  
48,3  
48,5  
---  
53,7  
53,8  
54,1  
54,3  
54,9  
55,5  
---  
60,4  
60,6  
60,8  
61,0  
61,7  
62,4  
---  
67,1  
67,3  
67,5  
67,7  
68,4  
69,3  
116,6 113,8 111,5  
129,3 126,0 123,0 120,4  
138,5 134,8 131,3 128,3 125,8  
164,1 159,3 154,7 150,4 146,7  
193,7 187,7 181,8 176,3 171,1 166,5  
89,5  
107,3 105,1  
128,2 124,9 122,2  
142,5 138,5 135,0 132,1  
152,8 148,3 144,2 140,8 138,1  
181,5 175,6 170,2 165,2 160,9  
215,0 207,5 200,4 193,8 187,9 182,6  
102,1  
120,8 119,3  
142,2 140,1 138,3  
156,7 154,1 151,7 149,7  
167,1 164,0 161,3 159,0 157,0  
196,2 191,8 187,9 184,5 181,5  
230,3 224,3 218,8 214,0 209,6 205,8  
112,0  
132,6 131,0  
156,1 153,9 152,0  
171,9 169,2 166,8 164,6  
183,3 180,1 177,3 174,8 172,6  
215,1 210,5 206,4 202,8 199,6  
252,7 246,1 240,2 235,0 230,5 226,4  
129,4  
153,1 150,9  
180,7 177,6 174,7  
199,5 195,6 192,1 189,0  
213,0 208,6 204,6 200,9 197,8  
250,8 244,8 239,3 234,1 229,5  
294,6 286,9 279,6 272,7 266,4 260,6  
149,4  
176,9 174,0  
209,6 205,2 201,3  
232,0 226,6 221,7 217,3  
248,1 242,1 236,5 231,4 227,0  
292,8 285,3 277,9 270,8 264,4  
344,3 335,1 326,0 316,9 308,4 300,4  
165,3  
197,1 193,4  
234,8 229,2 224,3  
260,5 253,7 247,6 242,4  
279,0 271,4 264,4 258,3 253,2  
330,7 320,8 311,5 302,9 295,2  
390,4 378,2 366,3 355,0 344,6 335,1  
181,2  
217,3 212,7  
259,9 253,1 247,4  
289,0 280,7 273,5 267,4  
310,0 300,7 292,3 285,1 279,3  
368,5 356,4 345,1 334,9 326,0  
436,5 421,2 406,7 393,1 380,8 369,8  
---  
8
38,6  
38,6  
38,7  
39,0  
---  
120  
10  
15  
20  
-5  
0
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
5
38,0  
38,0  
38,0  
38,2  
38,6  
---  
8
42,9  
42,9  
43,0  
43,2  
---  
---  
130  
140  
160  
190  
210  
240  
260  
10  
15  
20  
-5  
0
48,6  
48,5  
48,5  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
5
8
42,8  
43,0  
43,1  
43,0  
42,9  
---  
48,2  
48,4  
48,6  
48,5  
---  
---  
10  
15  
20  
-5  
0
54,1  
54,7  
54,8  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
5
8
47,0  
47,2  
47,2  
47,0  
46,8  
---  
52,9  
53,1  
53,2  
52,9  
---  
---  
10  
15  
20  
-5  
0
59,4  
60,0  
59,9  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
5
8
53,8  
54,0  
54,0  
54,2  
54,4  
---  
60,7  
60,8  
61,1  
61,3  
---  
---  
10  
15  
20  
-5  
0
68,4  
68,8  
69,1  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
5
8
60,6  
60,7  
60,8  
61,4  
62,1  
---  
68,4  
68,5  
68,9  
69,6  
---  
---  
10  
15  
20  
-5  
0
77,5  
77,7  
78,2  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
5
8
68,2  
68,3  
68,5  
68,9  
69,6  
---  
77,2  
77,2  
77,4  
78,0  
---  
---  
---  
85,9  
85,8  
85,9  
86,3  
---  
10  
15  
20  
-5  
0
5
8
10  
15  
20  
87,3  
87,3  
87,6  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
75,9  
76,0  
76,1  
76,5  
77,1  
---  
97,2  
97,0  
97,0  
109,4  
TU: Outlet water temperature (°C)  
TA: Ambient temperature dry bulb (°C)  
PA: Compressors input power (kW)  
PH: Heating capacity (kW)  
06617645-02  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EVAPORATOR PRESSURE DROPS  
80  
70  
60  
50  
40  
30  
20  
10  
80  
70  
A
B
E
G
H
C
60  
D
F
50  
40  
30  
20  
10  
15000  
20000  
25000  
30000  
5000  
10000  
15000  
20000  
A: QLAC 040-045  
B: QLAC 050  
C: QLAC 060-070  
D: QLAC 080  
E: QLAC 090  
F: QLAC 110  
G: QLAC 120  
H: QLAC 130  
80  
70  
60  
50  
40  
30  
20  
10  
60  
Q
R
T
S
50  
40  
30  
20  
10  
I
L
M
N
O
P
U
25000  
30000  
35000  
40000  
45000  
50000  
40000  
50000  
60000  
70000  
80000  
90000  
I: QLAC 140  
L: QLAC 160  
M: QLAC 190  
N: QLAC 210  
O: QLAC 240  
P: QLAC 260  
Q: QLAC 300  
R: QLAC 320  
S: QLAC 380  
T: QLAC 430  
U: QLAC 500  
06617645-02  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WATER PUMPS AVAILABLE STATIC PRESSURE  
240  
220  
200  
180  
160  
140  
120  
100  
80  
220  
D
200  
B
180  
A
C
160  
140  
120  
100  
80  
60  
60  
40  
5000  
10000  
15000  
20000  
15000  
20000  
25000  
30000  
A: QLAC 040,045,050,060,070  
B: QLAC 080, 090  
C: QLAC 110, 120  
D: QLAC 130, 140  
240  
220  
200  
180  
160  
140  
120  
100  
80  
220  
H
E
200  
180  
160  
140  
120  
100  
F
G
20000 25000 30000 35000 40000 45000 50000  
50000  
60000  
70000  
80000  
90000  
E: QLAC 160,190,210  
F: QLAC 240, 260  
G: QLAC 300, 320  
H: QLAC 380, 430, 500  
06617645-02  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FREE COOLING CAPACITY  
3
2,5  
2
7°C  
5°C  
12°C  
10°C  
1,5  
1
Return water temperature 15°C  
0,5  
0
-20  
-15  
-10  
-5  
0
5
10  
Ambient air temperature (°C)  
040  
---  
045  
---  
050  
43  
060  
43  
070  
43  
080  
45  
090  
70  
110  
72  
Mod.  
Nominal Free cooling capacity  
Mod.  
kW  
kW  
kW  
120  
72  
130  
72  
140  
94  
160  
94  
190  
110  
500  
240  
210  
115  
240  
135  
260  
135  
Nominal Free cooling capacity  
Mod.  
300  
185  
320  
185  
380  
235  
430  
245  
Nominal Free cooling capacity  
The nominal Free Cooling capacity is obtained when all compressors are OFF, the return water temperature  
from the system is 15°C and the ambient temperature is 2°C. to calculate the free cooling capacity in  
different conditions please refer to the above diagram. To obtain free cooling duty multiply the nominal Free  
Cooling capacity by the CFC factor obtained.  
06617645-02  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PARTIAL HEAT RECOVERY CAPACITY  
Mod.  
040  
9,5  
045  
12,8  
2200  
14  
050  
13,0  
2240  
11  
060  
15,0  
2580  
15  
070  
15,3  
2630  
16  
080  
18,5  
3190  
18  
090  
21,5  
3700  
11  
110  
24,8  
4270  
15  
Partial heat recovery nominal capacity  
Water flow  
kW  
l/h  
1635  
10  
Water pressure drops  
Mod.  
kPa  
120  
27,5  
4730  
13  
130  
30,0  
5160  
18  
140  
34,0  
5850  
18  
160  
190  
43,0  
7400  
11  
210  
49,0  
8430  
15  
240  
55,0  
9460  
19  
260  
Partial heat recovery nominal capacity  
Water flow  
kW  
l/h  
37,0  
6360  
25  
61,5  
10570  
25  
Water pressure drops  
Mod.  
kPa  
300  
69,0  
11850  
20  
320  
76,0  
13000  
25  
380  
91,5  
15750  
25  
430  
500  
114  
19600  
35  
Partial heat recovery nominal capacity  
Water flow  
kW  
l/h  
102,8  
17700  
29  
Water pressure drops  
kPa  
The nominal value refers to an ambient temperature 35°C and outlet water temperature 50°C (Dt 5°C).  
1,5  
1,4  
1,3  
1,2  
1,1  
1
Ambient temperature 40°C  
Ambient temperature 35°C  
Ambient temperature 30°C  
Ambient temperature 25°C  
Ambient temperature 20°C  
0,9  
0,8  
40  
41  
42  
43  
44  
45  
46  
47  
48  
49  
50  
Outlet water temperature °C  
The heat recovery capacity in different conditions can be obtained multiplying the nominal capacity (See above), by the correction  
factor indicated in the table.  
Warning Partial heat recovery can only work in cooling mode. In the heat pump version it is  
necessary to isolate the heat recovery circuit when in heating mode to prevent damage.  
Failure to comply with this will invalidate the warranty.  
06617645-02  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
COMPRESSORS CAPACITY STEP CONTROLS  
CORRECTION TABLE  
Glycol  
Operation with glycol  
WFCF  
Water temp.  
PDCF  
10%  
20%  
35%  
10%  
20%  
35%  
10%  
20%  
35%  
10%  
20%  
35%  
1,012  
1,048  
1,109  
0,870  
0,875  
0,925  
0,710  
0,730  
0,770  
---  
1,125  
1,32  
1,62  
0,85  
0,92  
1,13  
0,64  
0,85  
1,05  
---  
7
3
-2  
-5  
0,600  
0,625  
0,56  
0,7  
WFCF = Water flow correction factor  
PDCF = Pressure drop correction factor  
The water flow rate and pressure drop correction factors are to be applied directly to the values given for  
operation without glycol. The water flow rate correction factor is calculated in order to maintain the same  
temperature difference as that which would be obtained without glycol. The pressure drop correction factor  
takes into account the different flow rate obtained from the application of the flow rate correction factor.  
When the new flow rate is determind the capacity can be calculated using the formula Q=4.19m ΔT, where Q  
is the duty in kw, m is the flow rate in kg/s and ΔT is the fluid temperature difference.  
CORRECTION TABLES  
3
Different DT  
5
Water temperature  
difference  
CCCP  
8
0,99  
0,99  
1
1
1,02  
1,01  
IPCF  
CCCP = Cooling capacity correction factor IPCF = Input power correction factor  
CORRECTION TABLES  
0,00005  
Different Fouling factors  
0,0001  
Fouling factor  
0,0002  
CCCP  
IPCF  
1
1
0,98  
0,98  
0,94  
0,95  
CCCP = Cooling capacity correction factor IPCF = Input power correction factor  
06617645-02  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ELECTRICAL DATA  
Model  
Power line fuses  
040  
50  
045  
63  
050  
63  
060  
80  
070  
100  
080  
100  
090  
125  
110  
125  
A
10  
10  
16  
16  
25  
25  
25  
35  
mm²  
Power line cable section  
Model  
120  
130  
140  
160  
190  
210  
240  
260  
160  
200  
200  
200  
250  
250  
350  
400  
A
Power line fuses  
Power line cable section  
50  
50  
50  
50  
70  
95  
120  
150  
mm²  
400 / 3 / 50  
230 / 1 / 50  
24 / 1 / 50  
V/~/Hz  
V/~/Hz  
V/~/Hz  
V/~/Hz  
Power supply  
Auxiliary circuit  
Control board  
Fans power supply  
400 / 3 / 50  
Electrical data varies depending on specification. Always refer to the wiring diagram supplied in the unit.  
SOUND LEVELS LOW NOISE VERSION  
Octave bands (Hz)  
Lw  
Lp  
Model  
63  
dB  
125  
dB  
250  
dB  
500  
dB  
1K  
dB  
2K  
dB  
4K  
dB  
8K  
dB  
dB  
dB(A)  
dB(A)  
040/LS  
045/LS  
050/LS  
060/LS  
070/LS  
080/LS  
090/LS  
110/LS  
120/LS  
130/LS  
140/LS  
160/LS  
190/LS  
210/LS  
240/LS  
260/LS  
300/LS  
320/LS  
380/LS  
430/LS  
500/LS  
90.1  
90.1  
92.1  
92.1  
93.1  
93.1  
95.1  
95.6  
96.0  
96.2  
96.6  
97.1  
99.1  
99.1  
102.1  
102.1  
103.1  
103.1  
104.1  
104.1  
104.1  
91.3  
91.3  
83.3  
83.3  
84.3  
84.3  
86.3  
86.8  
87.2  
87.4  
87.8  
88.3  
90.3  
90.3  
93.3  
93.3  
94.3  
94.3  
95.3  
95.3  
95.3  
75.2  
75.2  
77.2  
77.2  
78.2  
78.2  
80.2  
80.7  
81.1  
81.3  
81.7  
82.2  
84.2  
84.2  
87.2  
87.2  
88.2  
88.2  
89.2  
89.2  
89.2  
73.3  
73.3  
75.7  
75.7  
76.7  
76.7  
78.7  
79.2  
79.6  
79.8  
80.2  
80.7  
82.7  
82.7  
85.7  
85.7  
86.7  
86.7  
87.7  
87.7  
87.7  
72.6  
72.6  
74.6  
74.6  
75.6  
75.6  
77.6  
78.1  
78.5  
78.7  
79.1  
79.6  
81.6  
81.6  
84.6  
84.6  
85.6  
85.6  
86.6  
86.6  
86.6  
67.2  
67.2  
69.2  
69.2  
70.2  
70.2  
72.2  
72.7  
73.1  
73.3  
73.7  
74.2  
76.2  
76.2  
79.2  
79.2  
80.2  
80.2  
81.2  
81.2  
81.2  
63.8  
63.8  
65.8  
65.8  
66.8  
66.8  
68.8  
69.3  
69.7  
69.9  
70.3  
70.8  
72.8  
72.8  
75.8  
75.8  
76.8  
76.8  
77.8  
77.8  
77.8  
54.7  
54.7  
56.7  
56.7  
57.7  
57.7  
59.7  
60.2  
60.6  
60.8  
61.2  
61.7  
63.7  
63.7  
66.7  
66.7  
67.7  
67.7  
68.7  
68.7  
68.7  
90.9  
90.9  
92.9  
92.9  
93.9  
93.9  
95.9  
96.4  
96.8  
97.0  
97.4  
98.0  
99.9  
77.0  
77.0  
79.0  
79.0  
80.0  
80.0  
82.0  
82.5  
82.9  
83.1  
83.5  
84.0  
86.0  
86.0  
89.0  
89.0  
90.0  
90.0  
91.0  
91.0  
91.0  
49  
49  
51  
51  
52  
52  
54  
54.5  
54.9  
55.1  
55.5  
56  
58  
58  
61  
61  
62  
62  
63  
63  
99.9  
102.9  
102.9  
103.9  
103.9  
104.9  
104.9  
104.9  
63  
SOUND LEVELS EXTRA LOW NOISE VERSION  
Octave bands (Hz)  
Lw  
Lp  
Model  
63  
dB  
125  
dB  
250  
dB  
500  
dB  
1K  
dB  
2K  
dB  
4K  
dB  
8K  
dB  
dB  
dB(A)  
dB(A)  
040/XL  
045/XL  
050/XL  
060/XL  
070/XL  
080/XL  
090/XL  
110/XL  
120/XL  
130/XL  
140/XL  
160/XL  
190/XL  
210/XL  
240/XL  
260/XL  
300/XL  
320/XL  
380/XL  
430/XL  
500/XL  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
48  
48  
50  
89.1  
89.1  
91.1  
91.1  
92.6  
93.0  
93.2  
93.6  
94.1  
94.4  
97.1  
97.1  
---  
---  
---  
---  
---  
---  
---  
80.3  
80.3  
82.3  
82.3  
83.8  
84.2  
84.4  
84.8  
85.3  
85.6  
88.3  
88.3  
---  
---  
---  
---  
---  
---  
---  
74.2  
74.2  
76.2  
76.2  
77.7  
78.1  
78.3  
78.7  
79.2  
79.5  
82.2  
82.2  
---  
---  
---  
---  
---  
---  
---  
72.7  
72.7  
74.7  
74.7  
76.2  
76.6  
76.8  
77.2  
77.7  
78.0  
80.7  
80.7  
---  
---  
---  
---  
---  
---  
---  
71.6  
71.6  
73.6  
73.6  
75.1  
75.5  
75.7  
76.1  
76.6  
76.9  
79.6  
79.6  
---  
---  
---  
---  
---  
---  
---  
66.2  
66.2  
68.2  
68.2  
69.7  
70.1  
70.3  
70.7  
71.2  
71.5  
74.2  
74.2  
---  
---  
---  
---  
---  
---  
---  
62.2  
62.2  
64.8  
64.8  
66.3  
66.7  
66.9  
67.3  
67.8  
68.1  
70.8  
70.8  
---  
---  
---  
---  
---  
---  
---  
53.7  
53.7  
55.7  
55.7  
57.2  
57.6  
57.8  
58.2  
58.7  
59.0  
61.7  
61.7  
---  
---  
---  
---  
---  
---  
---  
89.9  
89.9  
91.9  
91.9  
93.4  
93.8  
94.0  
94.4  
95.0  
95.3  
98.0  
98.0  
---  
---  
---  
---  
---  
---  
---  
76.0  
76.0  
78.0  
78.0  
79.5  
79.9  
80.1  
80.5  
81.0  
81.3  
84.0  
84.0  
---  
---  
---  
---  
---  
---  
---  
50  
51.5  
51.9  
52.1  
52.5  
53  
53.3  
58  
58  
---  
---  
---  
---  
---  
---  
---  
--- (not availble)  
Lw – Sound power level according to ISO 3746.  
Lp – Sound pressure level measured at 10 mt from the unit in free field conditions direction factor Q = 2 according to ISO 3746.  
06617645-02  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Instructions – General  
- When installing or servicing the unit, you must follow the instructions given in this manual and on labels  
attached to the unit.  
- As the chiller is charged with refrigerant under pressure and unauthorised access to the electrical  
components provides a shock hazard, any work performed on the unit must be by suitably trained  
personnel only.  
- Failure to observe the instructions provided in this manual, or any modification of the unit without explicit  
previous authorisation, will invalidate the warranty.  
Attention: before servicing the unit ensure that the electric supply is disconnected.  
Inspection  
After receiving the unit, immediately check its integrity. The unit left the factory in perfect condition; any  
eventual damage must be reported to the carrier and be recorded on the Delivery Note before it is signed.  
TEV Ltd must be informed, within 8 days, of the extent of the damage. The customer should prepare a  
written statement of any severe damage: digital photos of any damage is useful.  
Lifting and site handling  
When unloading the unit, care must be taken to prevent damage to the refrigerant circuit, condensing coils  
or unit casing.  
When using a crane, pass bars through the base frame lifting holes (marked with yellow arrows) and attach  
the cable or chains to these bars. Ensure that they are clamped firmly. Protect the sides of the chiller with  
boarding or material of a similar nature.  
Forklift forks must be inserted in the base pallet: care must be taken to prevent them hitting the base or  
panels. Keep the unit horizontal to avoid damage to the internal components.  
IMPORTANT: be sure that the method of lifting does not allow the unit to slip from chains or slings,  
turn over or slide from lifting devices.  
Unpacking  
When unpacking, be careful not to damage the unit. The packing is made up of different materials: wood,  
cardboard, polythene etc. We recommend that they are sent to a re-cycling centre in order to reduce their  
environmental impact.  
LOCATION AND MINIMUM CLEARANCES  
QLAC units are designed for external installation. Any overhang or cover above the unit should be avoided  
as this can cause air re-circulation. It is advisable to create a firm base for the unit, with a size similar to unit  
foot-print. Normal unit vibration levels are very low: it is good practice, however, to fit a rigid rubber interface  
between base and unit frame. Where desirable, fit anti-vibration mounts (spring or rubber), to keep vibration  
to a minimum. For future maintenance, these clearances are recommended:-  
Mod.  
040  
045  
050  
060  
070  
080  
090  
110  
120  
130  
140  
160  
190  
210  
240  
260  
300  
320  
380  
430  
500  
A
B
800  
800  
800  
800  
800  
800  
1000  
1000  
1000  
1000  
1000  
1000  
1000  
1000  
1000  
1000  
1000  
1000  
1000  
1000  
1000  
C
800  
800  
800  
800  
800  
800  
1000  
1000  
1000  
1000  
1000  
1000  
1000  
1000  
1000  
1000  
2000  
2000  
2000  
2000  
2000  
D
800  
800  
800  
800  
800  
800  
1000  
1000  
1000  
1000  
1000  
1000  
1000  
1000  
1000  
1000  
2000  
2000  
2000  
2000  
2000  
E
1000  
1000  
1500  
1500  
1500  
1500  
1500  
1500  
1500  
1500  
1500  
1500  
2000  
2000  
2000  
2000  
2000  
2000  
2000  
2000  
2000  
3000  
3000  
3000  
3000  
3000  
3000  
3000  
3000  
3000  
3000  
4000  
4000  
4000  
4000  
4000  
4000  
5000  
5000  
5000  
5000  
5000  
Warning: The unit should be installed such that there is suitable access for maintenance and/or  
repair.  
06617645-02  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HYDRAULIC CONNECTIONS  
Unit water pipe-work must be installed in accordance with national and local regulations. Pipes can be steel,  
galvanized steel, copper or PVC. Pipes have to be designed depending on the nominal water flow and the  
hydraulic pressure drops of the system. All pipes must be insulated with closed-cell material of adequate  
thickness. The chiller must be connected to the pipework using flexible joints. Piping should include:  
Temperature and pressure gauges for maintenance or servicing operations.  
Manual shut-off valves to separate the unit from the hydraulic circuit.  
Metallic supply water filter to be sited at the inlet pipe, with a mesh not larger than 1 mm.  
Vent valves, expansion tank with water filling, discharge valve.  
The water inlet must correspond with the connection labelled ”USER WATER INLET”, otherwise the  
evaporator may freeze.  
You must fit a metallic filter with a mesh not larger than 1 mm at the ‘USER WATER INLET’  
connection. If the flow switch is altered or the water filter is not fitted, the warranty will be  
invalidated. All units are supplied with flow switch, on ‘K’ versions it is factory installed, on standard  
versions it is supplied loose. The flow switch MUST be installed on the water outlet pipe. Please refer  
to the wiring diagram for the flow switch electrical connections  
LAC  
Standard  
LAC / K  
A
B
C
D
E
Water tank  
F
G
H
I
Water strainer  
Water pump  
Expansion vessel  
Safety valve  
Flexible connection  
Ball shut-off valve  
Vent valve  
System filling group  
06617645-02  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
(QLAC / FC FREE COOLING VERSION)  
FREE COOLING SYSTEMS MUST ALWAYS BE FILLED WITH GLYCOL SOLUTION  
The free cooling versions can operate in 3 different operating modes. The free-cooling coil is installed in  
series with the water chiller evaporator; the 3 way valve controls the water flow through the coil. When the  
ambient temperature is lower than the return water temperature, the microprocessor allows the water flow to  
pass through the free-cooling coil first, then through the evaporator.  
Cooling mode (Summer operation) Ambient temperature is higher than the return water temperature. In  
this case, the ambient conditions are not suitable to allow Free Cooling operation; the 3 way valve is closed  
and the water flows to the evaporator, where it is cooled. The compressors, fans, and the water pump are  
activated; the unit operates like a normal liquid cooler.  
Free cooling mode (Winter operation) Ambient temperature is much lower than the return water  
temperature. In this case, the ambient conditions are suitable to allow Free Cooling operation; the 3 way  
valve opens and the water flows into the free cooling coil, where the ambient conditions are sufficient to give  
the total required load. In this case the pump and the fans are in operation, while the compressors are  
stopped. In this case, the free cooling system works in substitution of the water chiller.  
Cooling mode + Free cooling (Mid-season operation) Ambient temperature is lower than the return water  
temperature. In this case, the ambient conditions are suitable to allow Free Cooling operation; the 3 way  
valve opens and water flow passes into the free cooling coil although the ambient conditions are not  
sufficiently low to give the total required load. The microprocessor control activates the compressors (pump  
and fans are already in operation) to satisfy the required load. In this case the free cooling system works in  
conjunction with the water chiller. In these circumstances the head pressure control device is activated.  
CONDENSING PRESSURE CONTROL (optional)  
If unit operation below 20°C is expected, a condensing pressure control must be fitted in the unit. This  
device will allow unit operation under low ambient temperature, by reducing condenser air flow and  
obtaining acceptable operating parameters. This device modulates the fan speed in proportion to the  
condensing pressure measured by the pressure transducer.  
This device is factory pre-set. The values must never be modified.  
OPERATIONAL LIMITS  
Evaporator water flow rate  
The nominal water flow rates are based on a delta T (Win - Wout) of 5 °C. The maximum flow rate allowed is  
that achieved with a delta T of 3 °C: higher values may cause too high pressure drop. The minimum water  
flow rate allowed is that achieved with a delta T of 8 °C. Insufficient values cause too low evaporating  
temperatures, tripping safety devices which stop the unit.  
Chilled water temperature (summer operation)  
The minimum temperature allowed at the evaporator outlet is 5 °C. To work below this limit, the unit  
requires modification - please contact TEV Ltd. The maximum temperature allowed at the evaporator inlet is  
20 °C.  
Hot water temperature (winter operation)  
Once the system is at temperature, the water temperature at the condenser inlet should not be less than 23  
°C: lower values could cause incorrect working operation of the compressor and compressor failure may  
occur. The maximum water temperature at the condenser outlet should not exceed 48 °C: higher values will  
cause safety devices to trip and stop operation.  
Ambient air temperature  
The units are designed and manufactured to operate, in cooling, with ambient air temperature between 20°C  
to 42 °C If a fan speed control is installed then the minimum ambient air temperature is -10°C. In winter  
operation (heat pump cycle) operates from -5°C to 20°C.  
06617645-02  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ELECTRICAL CONNECTIONS  
Disconnect the electrical supply before undertaking any work on the unit.  
All electrical work must be undertaken by suitably qualified personnel.  
The electrical supply must match the nominal electrical data (voltage, phase, frequency) shown on the label  
in the front panel of the unit. Power connections must be made in accordance to the wiring diagram enclosed  
with the unit and in accordance current local and national regulations. Power cable and line protection must  
be sized according to the specification stated on the wiring diagram enclosed with the unit.  
The variation in line voltage must not be more than ±5% of the nominal value, whilst the voltage imbalance  
between phases must not exceed 2%. If those tolerances are likely to be exceeded, please contact TEV  
Ltd., as further protection devices are required.  
Electrical supply must be as described, otherwise warranty will be invalid.  
START UP  
Before start-up  
- Check that all power cables are connected in the correct sequence and that all terminals are tight.  
- The voltage measured at the R Y B phase clamps must be 400 V ± 5% (or the value given on the rating  
plate for special voltages). If the voltage is incorrect, do not proceed.  
- Check for any refrigerant leaks using a leak detector. Should a leak be found do not proceed. All leaks  
must be rectified and the unit re-charged by trained personnel.  
- Check that the crankcase heaters are energised.  
Crankcase heaters must be energised at least 12 hours before start up by switching on the unit at  
the main switch.  
- Verify that heaters are working correctly. After a short warm up period, the compressor crankcase must be  
warm to the touch and must have a temperature at least 10K higher than ambient temperature.  
- Check that all hydraulic connections have been made correctly and that all information given on the unit's  
labels have been observed.  
- The system must be filled with water and bled to eliminate any air.  
Caution: before starting the unit up, check that all cover panels are correctly located and securely  
fastened.  
Start up  
Please refer to the microprocessor manual enclosed with the unit.  
If the unit fails to start:  
Check that the control thermostat is set to the correct value.  
Do not modify any internal wiring, otherwise warranty will be invalidated.  
Controls during unit operation  
Check the rotation of the fans. If the rotation is incorrect, disconnect the main switch and change over any  
two phases of the incoming main supply to reverse motor rotation:  
Check that water temperature at evaporator inlet is near to the set point of the control thermostat.  
For “K” version units (units with pumps and storage tank) if the motor driven pump is noisy, slowly  
close the discharge shut-off valve until normal working conditions are restored.  
This trouble may occur when system pressure drop is significantly different from pump available  
pressure.  
06617645-02  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Refrigerant charge checking  
A few minutes after start up, working on cooling operating mode, check that condensing temperature, is  
approximately 15 °C higher than condenser inlet air temperature. Also check that the evaporation  
temperature is about 5 °C lower than the evaporator outlet temperature.  
When the unit has stabilised, check that the sight glass core shows green: if the core is yellow,  
moisture is present in the circuit. In this case it is necessary to dehydrate the circuit (qualified personnel  
only). Check at the sight glass that there are no continuous vapour bubbles present. If so, additional  
refrigerant charge may be required. (A few vapour bubbles are acceptable).  
Check that refrigerant superheat on the evaporator is about 5-7 °C  
Check if refrigerant sub-cooling on the condenser is about 5-7 °C.  
Unit switch OFF  
Please refer to the microprocessor manual enclosed with the unit.  
Caution: For temporary stops (night time, weekend etc.) never switch off the unit by opening the mains  
switch: this should only be used to disconnect the unit from the power supply when current is not  
passing through it, i.e. when the unit is in ‘OFF’ mode. Additionally, with no supply to the crankcase  
heater, the compressor could be seriously damaged at unit start up.  
CONTROL AND SAFETY DEVICE SETTINGS  
Control devices - factory settings  
CAPACITY STEPS  
2
4
CONTROL DEVICE  
Set-point Differential Set point Differential  
10  
42  
2
2
9
43  
3
3
Control thermostat (cooling)  
Control thermostat (heating)  
°C  
°C  
Safety devices - factory settings  
CONTROL DEVICE  
Anti-freeze thermostat  
Electric heater thermostat  
High pressure switch  
Low pressure switch  
End defrosting pressure  
Defrosting set-point  
SET POINT  
DIFFERENTIAL  
RESET TYPE  
Manual  
4
4
6
6
7
1
--  
2
--  
°C  
°C  
Manual  
Manual  
Manual  
Automatic  
Automatic  
--  
28  
0,7  
18  
16  
6
bar  
bar  
bar  
bar  
bar  
Water safety valve (Optional)  
06617645-02  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MAINTENANCE AND PERIODIC CHECKS  
All maintenance and service operations MUST BE CARRIED OUT BY TRAINED PERSONNEL.  
Disconnect the electrical supply before undertaking any work on the unit. (Any servicing performed  
when the supply is connected will need a suitable risk assessment).  
The compressor casing and discharge line of the compressor are usually hot. Care should be taken  
when working in this area. Aluminium coil fins are very sharp and can cause serious wounds. Care  
should be taken when working in this area. After any servicing operation ensure that all covers are  
replaced and fastened with their locking screws.  
It is strongly recommended that regular maintenance checks are performed to maintain correct  
operation of the unit:-  
Every three months:  
- Check that safety and control devices work correctly as previously described.  
- Check all the terminals on the electric board and on the compressor are tight. Periodic cleaning of the  
terminals of the contactors should be done: if any damage is found, please replace the contactors.  
- Verify refrigerant charge by checking the sight glass.  
- Check that there is no oil leakage from the compressor.  
- Check that there is no water leakage from the hydraulic system.  
- If the unit is to be stopped for a long period, the unit hydraulic circuit, including all internal pipework and  
heat exchanger, should be emptied. This operation is compulsory if, during a seasonal shutdown, the  
ambient temperature is expected to go below the freezing point of the fluid in the hydraulic circuit (typical  
seasonal operation).  
- Check hydraulic circuit water level.  
- Check the flow switch operation .  
- Check the compressor crankcase heater power supply and operation.  
- Check defrosting procedure.  
- Clean drain pan and pipeline.  
- Clean mesh on water strainers.  
- Clean the finned coils metallic filters with compressed air. This should be in the opposite direction of the  
normal air flow. If filters become fully clogged, clean them with a water jet.  
Every six months:  
- Check the colour of the sight glass core (green = no moisture, yellow = moisture present).  
If it is yellow, the refrigerant circuit should be dehydrated and the refrigerant filter/drier changed.  
- Check the unit noise level.  
- Check mounting of fan blades and their balancing, check the tension and the wear of the belt.  
REFRIGERANT CIRCUIT REPAIR  
If the refrigerant circuits need to be evacuated,, all the refrigerant must be recovered using suitable  
equipment. The system must be charged with nitrogen, using a gas bottle with a pressure reducing valve,  
until 15 bar pressure is reached. Search for leaks with a bubble leak finder. If bubbles appear, discharge  
the circuit before repairing by brazing with a suitable braze alloy. Never use oxygen instead of nitrogen:  
explosions may occur.  
06617645-02  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Environmental Protection  
European legislation regarding the use of ozone depleting substances forbids the release of refrigerants to  
the atmosphere. They must be reclaimed and returned to the vendor, or to authorised re-cyclers at the end  
of their operating life.  
R407C refrigerant is deemed to be a controlled substance and is therefore subject to this legislation.  
Particular care is required during servicing operations in order to prevent refrigerant loss.  
De-commissioning  
When the unit reaches the end of its service life and requires removal or replacement, the following  
operations are recommended:-  
- the unit refrigerant must be reclaimed by trained personnel and returned to an authorised re-cycling centre  
- compressor lubricating oil should be recovered and sent to an authorised re-cycling centre  
- the unit frame, coil, heat exchanger etc, should be dismantled and subdivided into material type; bear in  
mind that copper and aluminium are present in substantial quantities in the unit.  
These operations aid material recovery and recycling processes, reducing environmental impact.  
06617645-02  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DIMENSIONS  
06617645-02  
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
06617645-02  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
06617645-02  
34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
06617645-02  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
06617645-02  
36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
06617645-02  
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
06617645-02  
38  
Download from Www.Somanuals.com. All Manuals Search And Download.  
06617645-02  
39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
06617645-02  
40  
Download from Www.Somanuals.com. All Manuals Search And Download.  
06617645-02  
41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TEV LTD, ARMYTAGE ROAD, BRIGHOUSE, WEST YORKSHIRE, HD6 1QF. TEL: + 44 (0) 1484 405630 FAX: +44 (0) 1484 405620  
06617645-02  
42  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Riccar Vacuum Cleaner GEM R User Guide
RocketFish Power Supply RF 500WPS2 User Guide
Rotel Cassette Player RD 955AX User Guide
Rotel Stereo Amplifier RTC 965 User Guide
Samsung Blu ray Player BD F5900 User Guide
Samsung Printer ML 2010 Series User Guide
Samsung Printer SCX 4500 User Guide
Sanyo Battery Charger KR SCH16 User Guide
Sears Lawn Mower 91725271 User Guide
Senco Nail Gun SHF15 User Guide