Quantum Wheelchair Quantum R 4000 3MP User Guide

QUANTUM  
SERIES  
Including Models: Quantum R-4000 3S, Quantum R-4000 3SP, Quantum R-4000 3MP,  
Quantum R-4400 4S, Quantum R-4400 4SP, Quantum R-4400 4MP  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CONTENTS  
I.  
INTRODUCTION ................................................................................................................................... 4  
II. SAFETY .................................................................................................................................................... 5  
III. YOUR POWER CHAIR ...................................................................................................................... 18  
IV. ASSEMBLY ........................................................................................................................................... 22  
V. COMFORT ADJUSTMENTS ........................................................................................................... 23  
VI. BATTERIES AND CHARGING ...................................................................................................... 28  
VII. CARE AND MAINTENANCE .......................................................................................................... 32  
APPENDIX I - SPECIFICATIONS .......................................................................................................... 37  
Quantum R-4000  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
I. INTRODUCTION  
SAFETY  
WELCOME to Quantum Rehab, a division of Pride Mobility Products Corporation (Pride). The power chair you  
have purchased combines state-of-the-art components with safety, comfort, and styling in mind. We are confident  
that these design features will provide you with the conveniences you expect during your daily activities. Once  
you understand how to safely operate and care for your power chair, it should give you years of trouble-free  
operation and service.  
Read and follow all instructions, warnings, and notes in this manual before attempting to operate your power chair  
for the first time. You must also read all instructions, warnings, and notes contained in any supplemental instruc-  
tional booklets for the controller, front riggings, and/or seating system that accompanied your power chair before  
initial operation. Your safety depends upon you, as well as your provider, caretaker, or healthcare professional in  
using good judgement.  
If there is any information in this manual which you do not understand, or if you require additional assistance for  
setup or operation, please contact your Quantum Rehab Provider. Failure to follow the instructions in this  
manual and those located on your power chair can lead to personal injury and/or damage to the power  
chair, and may void the warranty.  
PURCHASER’S AGREEMENT  
By accepting delivery of this product, you promise that you will not change, alter, or modify this product or remove  
or render inoperable or unsafe any guards, shields, or other safety features of this product; fail, refuse, or neglect to  
install any retrofit kits from time to time provided by Pride to enhance or preserve the safe use of this product.  
SHIPPING AND DELIVERY  
Before using your power chair, make sure your delivery is complete as some components may be individually  
packaged. If you do not receive a complete delivery, please contact your Quantum Rehab Provider immediately.  
Where damage has occurred during transport, either to the packaging or content, please contact the delivery com-  
pany responsible.  
INFORMATION EXCHANGE  
We want to hear your questions, comments, and suggestions about this manual. We would also like to hear about the  
safety and reliability of your new power chair, and about the service you received from your Quantum Rehab Provider.  
Please notify us of any change of address, so we can keep you apprised of important information about safety,  
new products, and new options that can increase your ability to use and enjoy your power chair. Please feel free  
to contact us at the address below:  
USA:  
Canada:  
Pride Mobility Products Corporation  
Attn.: Customer Care Department  
182 Susquehanna Avenue  
Exeter, PA 18643-2694  
1-800-424-8205  
Pride Mobility Products Company  
380 Vansickle Road Unit 350  
St. Catharines, Ontario L2R 6P7  
1-888-570-1113  
NOTE: If you ever lose or misplace your product registration card or your copy of this manual, contact us and  
we will be glad to send you a new one immediately.  
4
Quantum R-4000  
Download from Www.Somanuals.com. All Manuals Search And Download.  
II. SAFETY  
PRODUCT SAFETY SYMBOLS  
The symbols below are used on the power chair to identify warnings, mandatory actions, and prohibited actions.  
It is very important for you to read and understand them completely.  
Read and follow the information in the owner’s manual.  
Do not allow unsupervised children to play near the power chair while the batteries are  
charging.  
Maximum seating weight.  
Keep your hands away from the tires when driving. Be aware that loose fitting clothing  
can become caught in drive tires.  
Use correct tie-down points for controller harness to prevent the harness from getting  
caught in the drive tires, pinched in the seat frame, or damaged when passing through  
doorways.  
Avoid exposure to rain, snow, ice, salt, or standing water whenever possible. Maintain  
and store in a clean and dry condition.  
Quantum R-4000  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
II. SAFETY  
Pinch/Crush points created during assembly.  
Do not remove anti-tip wheels.  
Do not connect an extension cord to the AC/DC converter or the battery charger.  
Removal of grounding prong can create electrical hazard. If necessary, properly install  
an approved 3-pronged adapter to an electrical outlet having 2-pronged plug access.  
Wear safety goggles.  
Corrosive chemicals contained in battery.  
Do not use a cell phone, walkie/talkie, laptop, or other radio transmitter while operating.  
6
Quantum R-4000  
Download from Www.Somanuals.com. All Manuals Search And Download.  
II. SAFETY  
EMI-RFI - This product has been tested and passed at an immunity level of 20 V/m.  
Explosive conditions exist!  
Use only AGM or Gel-Cell batteries to reduce the risk of leakage or explosive conditions.  
Keep tools and other metal objects away from battery terminals. Contact with tools can  
cause electrical shock.  
Battery Set Configuration:  
+ = Positive (Red) Terminal Post  
- = Negative (Black) Terminal Post  
Connect Red wire to Red Positive (+) Terminal Post  
Connect Black wire to Black Negative (–) Terminal Post  
Do not use batteries with different amp-hour (Ah) capacities. Do not mix old and new  
batteries. Always replace both batteries at the same time.  
Quantum R-4000  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
II. SAFETY  
Battery charger for indoor use only.  
Disposal and recycling — Contact your Quantum Rehab Provider for information on  
proper disposal and recycling of your Pride product and its packaging.  
Locked and in drive mode.  
Place unit on level ground and stand to one side when changing from drive mode to  
freewheel mode or freewheel mode to drive mode.  
Unlocked and in freewheel mode.  
Do not place power chair in freewheel mode on a decline.  
Do not place power chair in freewheel mode on an incline.  
8
Quantum R-4000  
Download from Www.Somanuals.com. All Manuals Search And Download.  
II. SAFETY  
Contains Lead.  
No step. No standing. Keep off!  
Quantum R-4000  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
II. SAFETY  
GENERAL GUIDELINES  
MANDATORY! Do not operate your new power chair for the first time without completely reading  
and understanding this owner’s manual.  
Your power chair is a state-of-the-art life-enhancement device designed to increase mobility. Pride provides an  
extensive variety of products to best fit the individual needs of the power chair user. Please be aware that the final  
selection and purchasing decision regarding the type of power chair to be used is the responsibility of the power  
chair user, who is capable of making such a decision, and his/her healthcare professional (i.e., medical doctor,  
physical therapist, etc.).  
The contents of this manual are based on the expectation that a mobility device expert has properly fitted the  
power chair to the user and has assisted the prescribing healthcare professional and/or the Quantum Rehab Pro-  
vider in the instruction process for the use of the product.  
There are certain situations, including some medical conditions, where the power chair user will need to practice  
operating the power chair in the presence of a trained attendant. A trained attendant can be defined as a family  
member or care professional specially trained in assisting a power chair user in various daily living activities.  
As you begin using your power chair during daily activities, you will probably encounter situations in which you  
will need some practice. Simply take your time and you will soon be in full and confident control as you maneuver  
through doorways, on and off of elevators, up and down ramps, and over moderate terrain.  
Below are some precautions, tips, and other safety considerations that will help you become accustomed to oper-  
ating your power chair safely.  
Modifications  
Pride has designed and engineered your power chair to provide maximum mobility and utility. However, under  
no circumstances should you modify, add, remove, or disable any feature, part, or function of your power chair.  
WARNING! Do not modify your power chair in any way not authorized by Pride. Do not use  
accessories if they have not been tested or approved for Pride products.  
Pre-Ride Safety Check  
Get to know the feel of your power chair and its capabilities. Pride recommends that you perform a safety check  
before each use to make sure your power chair operates smoothly and safely.  
Perform the following inspections prior to using your power chair:  
Check for proper tire inflation. Maintain but do not exceed the psi/bar/kPa air pressure rating indicated on each  
tire if equipped with pneumatic tires.  
Check all electrical connections. Make sure they are tight and not corroded.  
Check all controller connections to the power base. Make sure they are secured properly.  
Check the brakes. See VII. “Care and Maintenance.”  
Check battery charge. See VI. “Batteries and Charging.”  
NOTE: If you discover a problem, contact your Quantum Rehab Provider for assistance.  
10  
Quantum R-4000  
Download from Www.Somanuals.com. All Manuals Search And Download.  
II. SAFETY  
Weight Limitations  
Your power chair is rated for a maximum weight capacity. Please refer to the specifications table for this limit.  
Keep in mind that the maximum weight capacty includes the combined weight of the user and any accessories  
mounted to the power chair.  
MANDATORY! Stay within the specified weight capacity of your power chair. Exceeding the  
weight capacity voids your warranty. Pride will not be held responsible for injuries and/or  
property damage resulting from failure to observe weight limitations.  
WARNING! Do not carry passengers on your power chair. Carrying passengers on your power  
chair may affect the center of gravity, resulting in a tip or a fall.  
Tire Inflation  
If your power chair is equipped with pneumatic tires, you should check or have the air pressure checked regularly.  
Proper inflation pressures will prolong the life of your tires and help ensure the smooth operation of your power  
chair.  
WARNING! It is important that the psi/bar/kPa air pressure rating indicated on the tire be  
maintained in pneumatic tires at all times. Do not underinflate or overinflate your tires. Low  
pressure may result in loss of control, and overinflated tires may burst. Failure to maintain the  
psi/bar/kPa air pressure rating indicated on the pneumatic tires at all times may result in tire  
and/or wheel failure.  
WARNING! Inflate your power chair drive tires from a regulated air source with an available  
pressure gauge. Inflating your tires from an unregulated air source could overinflate them,  
resulting in a burst tire.  
WARNING! When changing a tire, remove only the center lug nut, then remove the wheel. If any  
further disassembly is required, deflate the tire completely or it may explode.  
NOTE: If the tires on your power chair list the psi rating only, use the following conversion formulas to  
find the bar or kPa rating: bar = psi x 0.06895; kPa = psi x 6.89476.  
Incline Information  
More and more buildings have ramps with specified degrees of inclination, designed for easy and safe access.  
Some ramps may have turning switchbacks (180-degree turns) that require you to have good cornering skills on  
your power chair.  
Proceed with extreme caution as you approach the downgrade of a ramp or other incline.  
Take wide swings with your power chair’s front wheels around any tight corners. If you do that, the power  
chair’s rear wheels will follow a wide arc, not cut the corner short, and not bump into or get hung up on any  
railing corners.  
When driving down a ramp, keep the power chair’s speed adjustment set to the slowest speed setting to ensure  
a safely controlled descent.  
Avoid sudden stops and starts.  
When climbing an incline, try to keep your power chair moving. If you must stop, start up again slowly and then  
accelerate cautiously. When driving down an incline, set your power chair to the slowest speed setting and drive  
in the forward direction only. If your power chair starts to move down the incline faster than you anticipated or  
desired, allow it to come to a complete stop by releasing the joystick, then push the joystick forward slightly to  
ensure a safely controlled descent.  
WARNING! When on any sort of an incline or decline, never place the power chair in  
freewheel mode while seated on it or standing next to it.  
WARNING! When climbing an incline, do not zigzag or drive at an angle up the face of  
the incline. Drive your power chair straight up the incline. This greatly reduces the  
possibility of a tip or a fall. Always exercise extreme caution when negotiating an  
incline.  
WARNING! You should not travel up or down a potentially hazardous incline (i.e.,  
areas covered with snow, ice, cut grass, or wet leaves).  
Quantum R-4000  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
II. SAFETY  
WARNING! Never travel down an incline backward. Doing so may cause the powerchair to tip.  
Always exercise extreme caution when negotiating an incline.  
WARNING! If your power chair is equipped with a reclining seatback, do not attempt to negotiate  
inclines with the seat in a reclined position. Do not attempt to negotiate obstacles with the seat  
in a reclined position unless an attendant is present to help stabilize the chair. Failure to heed  
could result in the power chair tipping over.  
WARNING! Even though your power chair is capable of climbing slopes greater than those  
illustrated in figure 1, do not, under any circumstances, exceed the incline guidelines or any  
other specifications presented in this manual. Doing so could cause instability in your power  
chair.  
Pride recommends that the maximum slope of an incline you attempt to safely ascend or descend on your power  
chair does not exceed 6° (10.5%). See figure 1.  
WARNING! Any attempt to climb or descend a slope steeper than 6° (10.5%) may put your power  
chair in an unstable position and cause it to tip.  
Figure 1. Maxim um Safe Slope (Ascending and Descending)  
Freewheel Mode  
Your power chair is equipped with two manual freewheel levers to allow for manual maneuverability by a trained  
attendant. For more information about how to place your power chair into and out of freewheel mode, see III.  
“Your Power Chair.”  
WARNING! Do not use your power chair in freewheel mode without an attendant  
present.  
WARNING! Do not attempt to personally place your power chair in freewheel mode  
while seated on it. Ask an attendant for assistance if necessary.  
WARNING! Do not place your power chair in freewheel mode while on an incline or  
decline. This could cause the chair to roll uncontrollably on its own.  
Braking Information  
Your power chair is equipped with two powerful brake systems:  
Regenerative — uses electricity to rapidly slow the vehicle when the joystick returns to the center/stop  
position.  
Disc Park Brake — activates mechanically after regenerative braking slows the vehicle to near stop, or when  
power is removed from the system for any reason.  
Cornering Information  
While your power chair is equipped with front caster wheels and rear anti-tip wheels, excessively high cornering  
speeds can still create the possibility of tipping. Factors which affect the possibility of tipping include, but are not  
limited to: cornering speed, steering angle (how sharply you are turning), uneven road surfaces, inclined road  
surfaces, riding from an area of low traction to an area of high traction (such as passing from a grassy area to a  
paved area – especially at high speed while turning), and abrupt directional changes. High cornering speeds are  
not recommended. If you feel that you may tip over in a corner, reduce your speed and steering angle (i.e., lessen  
the sharpness of the turn) to prevent your power chair from tipping.  
12  
Quantum R-4000  
Download from Www.Somanuals.com. All Manuals Search And Download.  
II. SAFETY  
WARNING! When cornering sharply, reduce your speed and maintain a stable center of gravity.  
This greatly reduces the possibility of a tip or fall.  
Public Streets and Roadways  
WARNING! You should not operate your power chair on public streets and roadways. Be aware  
that it may be difficult for traffic to see you when you are seated on your power chair. Obey all  
local pedestrian traffic rules. Wait until your path is clear of traffic, and then proceed with  
extreme caution.  
Outdoor Driving Surfaces  
Your power chair is designed to provide optimum stability under normal driving conditions—dry, level surfaces  
composed of concrete, blacktop, or asphalt. However, Pride recognizes that there will be times when you will  
encounter other surface types. For this reason, your power chair is designed to perform admirably on packed soil,  
grass, and gravel. Feel free to use your power chair safely on lawns and in park areas.  
Avoid driving on uneven terrain and/or soft surfaces.  
Avoid tall grass that can entangle the running gear.  
Avoid loosely packed gravel and sand.  
Do not use your scooter in fresh or salt water.  
Do not use your scooter at the edge of a stream, lake, or ocean.  
If you feel unsure about a driving surface, avoid that surface.  
Inclement Weather Precautions  
Exposure of your power chair to inclement weather conditions should be avoided whenever possible. If suddenly  
caught up in rain, snow, severe cold or heat while operating your power chair, proceed to shelter at the earliest  
opportunity. Thoroughly dry your power chair before storing, charging, or operating your power chair.  
PROHIBITED! Operating in rain, snow, salt, mist/spray conditions, and on icy/slippery surfaces  
can have an adverse affect on the electrical system. Maintain and store your power chair in a  
dry and clean condition.  
WARNING! Prolonged exposure to hot or cold conditions may affect the temperature of  
upholstered and non-upholstered items on the power chair, possibly resulting in skin irritation.  
Exercise caution when using the power chair in extremely hot or cold conditions or when  
exposing your power chair to direct sunlight for prolonged periods of time.  
Stationary Obstacles (Steps, Curbs, etc.)  
Proceed with extreme caution when driving near raised surfaces, unprotected ledges, and/or drop-offs (curbs,  
porches, stairs, etc.). Be sure your power chair is traveling perpendicular to any curb you may be required to  
navigate.  
To navigate up over a curb or stationary obstacle:  
1. Approach the curb or obstacle slowly, and make sure the power chair is traveling perpendicular to the obstacle.  
See figure 2.  
2. Increase the forward speed just before the front wheels come in contact with the obstacle.  
3. Reduce the forward speed only after the rear wheels have cleared the obstacle.  
To navigate down a curb or stationary obstacle:  
1. Approach the curb or obstacle slowly, and make sure the power chair is traveling perpendicular to the obstacle.  
See figure 2.  
2. Reduce the forward speed just before the front wheels come in contact with the obstacle.  
3. Increase the forward speed only after the rear wheels have cleared the obstacle and you are once again on a  
level surface.  
Quantum R-4000  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
II. SAFETY  
Figure 2. Correct Curb Approach  
Figure 3. Incorrect Curb Approach  
WARNING! Even though your power chair may be capable of handling greater obstacles, Pride  
recommends that you do not attempt to negotiate a curb that has a height greater than 2 in. (5  
cm). Doing so could cause instability in your power chair.  
WARNING! Do not attempt to have your power chair proceed rearward down any step, curb, or  
other obstacle. This may cause the power chair to tip.  
Stairs and Escalators  
Power chairs are not designed to travel up or down stairs or escalators. Always use an elevator.  
WARNING! Never use your power chair to negotiate steps or escalators.  
Doors  
Determine if the door opens toward or away from you.  
Drive your power chair gently and slowly forward to push the door open. Or drive your power chair gently  
and slowly rearward to pull the door open.  
Elevators  
Modern elevators have a door edge safety mechanism that, when pushed, reopens the elevator door(s).  
If you are in the doorway of an elevator when the door(s) begin to close, push on the rubber door edge or allow  
the rubber door edge to contact the power chair and the door will reopen.  
Use care that pocketbooks, packages, or power chair accessories do not become caught in elevator doors.  
Lift Systems/Elevation Products  
If you will be transporting your power chair during travel, you may find it necessary to use a vehicle-mounted lift  
system or elevation product to aid in transportation. Pride recommends that you closely review the warnings,  
instructions, specifications, and safety information set forth by the manufacturer of the lift/elevation product  
before using that product.  
WARNING! Not all lift systems/elevation products are rated for use with an occupied mobility  
device. Pride recommends that you do not remain seated in your power chair when it is being  
used in connection with any type of lift system/elevation product unless:  
That product is rated for occupied use by the manufacturer.  
You are able to occupy your mobility device in strict conformity with the warnings,  
instructions, specifications, and safety guidelines set forth by the manufacturer.  
WARNING! Always turn off the power to the controller when you are being transferred via an  
elevation product. Failure to do so may result in accidental joystick contact, resulting in  
unintended movement and personal injury or product damage.  
14  
Quantum R-4000  
Download from Www.Somanuals.com. All Manuals Search And Download.  
II. SAFETY  
Motor Vehicle Transport  
Pride recommends that you do not remain seated in your power chair while traveling in a motor vehicle. The  
power chair should be stowed in the trunk of a car or in the back of a truck or van with batteries removed and  
properly secured. In addition, all removable power chair parts, including the armrests, seat, front riggings, con-  
troller, and shrouds should be removed and/or properly secured during motor vehicle transport.  
WARNING! Do not sit on your power chair while it is in a moving vehicle.  
WARNING! Always be sure your power chair and its batteries are properly secured when it is  
being transported. Batteries should be secured in an upright position and protective caps should  
be installed on the battery terminals. Batteries should not be transported with any flammable or  
combustible items.  
Positioning Belts  
Your Quantum Rehab Provider, therapist(s), and other healthcare professionals are responsible for determining  
your requirement for a positioning belt in order to operate your power chair safely.  
WARNING! If you require a positioning belt to safely operate your power chair, make sure it is  
fastened securely in order to reduce the possibility of a fall from the power chair.  
WARNING! The positioning belt is not designed for use as a seat belt in a motor vehicle. Nor is  
your power chair suitable for use as a seat in any vehicle. Anyone traveling in a vehicle should  
be properly belted into seats approved by the vehicle manufacturer.  
Batteries  
In addition to following the warnings below, be sure to comply with all other battery handling information. For  
more information about your power chair’s batteries, see VI. “Batteries and Charging.”  
MANDATORY! Battery posts, terminals, and related accessories contain lead and lead  
compounds. Wear goggles and gloves when handling batteries and wash hands after  
handling.  
WARNING! Power chair batteries are heavy. See specifications table. If you are unable  
to lift that much weight, be sure to get help. Use proper lifting techniques and avoid  
lifting beyond your capacity.  
WARNING! Always protect the batteries from freezing and never charge a frozen  
battery. Charging a frozen battery may result in damage to the battery.  
WARNING! Connect the battery harnesses in the proper manner. RED (+) cables must  
be connected to positive (+) battery terminals/posts. BLACK (-) cables must be  
connected to negative (-) battery terminals/posts. Protective caps should be installed  
over all battery terminals. REPLACE cables immediately if damaged.  
Removable Parts  
WARNING! Do not attempt to lift or move a power chair by any of its removable parts, including  
the armrests, seat, front riggings, controller, and shrouds.  
Preventing Unintended Movement  
WARNING! If you anticipate being seated in a stationary position for an extended period of time,  
turn off the power. This will prevent unexpected motion from inadvertent joystick contact. This will  
also eliminate the possibility of unintended chair movement from electromagnetic (EM) sources.  
Quantum R-4000  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
II. SAFETY  
Transfers  
Transferring onto and off of your power chair requires  
a good sense of balance. Always have an attendant or  
healthcare professional present while learning to prop-  
erly transfer yourself.  
To eliminate the possibility of injury, Pride recom-  
mends that you or a trained attendant perform the fol-  
lowing tasks before attempting a transfer:  
Turn off the power to the controller.  
Ensure your power chair is not in freewheel mode.  
See III. “Your Power Chair.”  
Turn the caster wheels toward the transfer  
destination to improve power chair stability during  
transfer.  
Make sure both armrests are flipped up or removed  
from your power chair.  
Flip up the foot platform or move the leg rests  
aside; this will help to keep your feet from getting  
caught on the front riggings during the transfer.  
Reduce the distance between your power chair and  
the object you are transferring onto.  
Figure 4. Ideal Transfer Position  
WARNING! Before transferring, position yourself as far back as possible in the power chair seat  
to prevent the power chair from tipping forward during transfer.  
WARNING! Avoid putting all of your weight on the power chair armrests and do not use the  
armrests for weight bearing purposes, such as transfers. Such use may cause the power chair  
to tip, resulting in a fall from the power chair and personal injury.  
WARNING! The controller and controller bracket are non-load bearing items on your power chair.  
Do not use the controller or controller bracket for weight bearing purposes, such as transfers.  
Such use may cause damage to these components, resulting in a fall from the power chair and  
personal injury.  
WARNING! Avoid putting all of your weight on the front riggings. Such use may cause the power  
chair to tip.  
Prescription Drugs/Physical Limitations  
Users must exercise care and common sense when operating a power chair. This includes awareness of safety  
issues when taking prescribed or over-the-counter drugs or when the user has specific physical limitations.  
WARNING! Consult your physician if you are taking prescribed or over-the-counter medication or  
if you have certain physical limitations. Some medications and limitations may impair your  
ability to operate your power chair in a safe manner.  
16  
Quantum R-4000  
Download from Www.Somanuals.com. All Manuals Search And Download.  
II. SAFETY  
Reaching and Bending  
Never reach, lean, or bend while driving your power chair. If it is absolutely necessary to reach, lean, or bend  
while seated on your power chair, it is important to maintain a stable center of gravity and keep the power chair  
from tipping. Pride recommends that the power chair user determine his/her personal limitations and practice  
bending and reaching in the presence of a qualified healthcare professional.  
WARNING! Do not bend, lean, or reach for objects if you have to pick them up from the  
floor by reaching down between your knees or if you have to reach over the back of the  
seat. Movements such as these may change your center of gravity and the weight  
distribution of the power chair. This may cause your power chair to tip.  
WARNING! Keep your hands away from the tires when driving. Be aware that loose  
fitting clothing can become caught in drive tires.  
Alcohol/Smoking  
The power chair user must exercise care and common sense when operating his/her power chair. This includes  
awareness of safety issues while under the influence of alcohol or while smoking.  
WARNING! Do not operate your power chair while you are under the influence of alcohol, as this  
may impair your ability to operate your power chair in a safe manner.  
WARNING! Pride strongly recommends that you do not smoke cigarettes while seated in your  
power chair, although the power chair has passed the necessary testing requirements for  
cigarette smoking. You must adhere to the following safety guidelines if you decide to smoke  
cigarettes while seated in your power chair.  
Do not leave lit cigarettes unattended.  
Keep ashtrays a safe distance from the seat cushions.  
Always make sure cigarettes are completely extinguished before disposal.  
Electromagnetic and Radio Frequency Interference (EMI/RFI)  
WARNING! Laboratory tests have shown that electromagnetic and radio frequency waves can  
have an adverse affect on the performance of electrically-powered mobility vehicles.  
Electromagnetic and Radio Frequency Interference can come from sources such as cellular phones, mobile two-  
way radios (such as walkie-talkies), radio stations, TV stations, amateur radio (HAM) transmitters, wireless com-  
puter links, microwave signals, paging transmitters, and medium-range mobile transceivers used by emergency  
vehicles. In some cases, these waves can cause unintended movement or damage to the control system. Every  
electrically-powered mobility vehicle has an immunity (or resistance) to EMI. The higher the immunity level, the  
greater the protection against EMI. This product has been tested and has passed at an immunity level of 20 V/m.  
WARNING! Be aware that cell phones, two-way radios, laptops, and other types of radio  
transmitters may cause unintended movement of your electrically-powered mobility vehicle due  
to EMI. Exercise caution when using any of these items while operating your mobility vehicle  
and avoid coming into close proximity of radio and TV stations.  
WARNING! The addition of accessories or components to the electrically-powered mobility  
vehicle can increase the susceptibility of the vehicle to EMI. Do not modify your power chair in  
any way not authorized by Pride.  
WARNING! The electrically-powered mobility vehicle itself can disturb the performance of other  
electrical devices located nearby, such as alarm systems.  
tended motion or brake release occurs, turn your power chair off as soon as it is safe to do so. Contact your  
Quantum Rehab Provider to report the incident.  
Quantum R-4000  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
III. YOUR POWER CHAIR  
THE QUANTUM R-4000 SERIES POWER CHAIR  
Your power chair has two main assemblies: the seat and the power base. See figures 5 and 6. Typically, the seat  
assembly includes the armrests, seatback, and seat base. The power base assembly includes two motor/brake  
assemblies, two drive wheels, two anti-tip wheels, two caster wheels, two batteries, and wiring harnesses.  
SEATBACK  
ARMREST  
SEAT ASSEMBLY  
CONTROLLER (VR2 SHOWN)  
SEAT BASE  
POWER  
BASE ASSEMBLY  
FRONT RIGGINGS  
DRIVE WHEEL  
CASTER WHEEL  
Figure 5. The Quantum R-4000  
18  
Quantum R-4000  
Download from Www.Somanuals.com. All Manuals Search And Download.  
III. YOUR POWER CHAIR  
CONTROLLER CONNECTOR  
FRONT TRAPEZE BAR  
FRONT SHROUD  
MANUAL FREEWHEEL LEVER  
MOTOR/BRAKE ASSEMBLY  
MAIN CIRCUIT BREAKER  
Figure 6. The Quantum R-4000 Power Base  
BATTERY DOOR LATCH LOCATION  
CONTROLLER HARNESS  
ANTI-TIP WHEEL  
BATTERY DOOR LATCH  
BATTERY DOOR  
ANTI-TIP WHEEL  
Figure 7. The Quantum R-4000 Power Base (Rear View - Battery Door Down)  
Quantum R-4000  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
III. YOUR POWER CHAIR  
Electrical Components  
The electrical components are located on the front of the power base or on the battery door at the rear of the power  
base depending on the power chair electrical system. See figures 6 and 7.  
Main Circuit Breaker: The main circuit breaker is a safety feature built into your power chair. When the batteries  
and the motors are heavily strained (e.g., from excessive loads), the main circuit breaker trips to prevent damage  
to the motors and the electronics. If the circuit trips, allow your power chair to “rest” for approximately one  
minute. Next, push in the circuit breaker button, turn on the controller, and continue normal operation. If the main  
circuit breaker continues to trip repeatedly, contact your Quantum Rehab Provider.  
Controller Connector: This is where the controller connects to the power base. The controller connector is  
located at the front or rear of the power base. See figure 6.  
Sport-Trac Suspension  
Your power chair is equipped with Sport-Trac Suspension (STS). STS is a suspension system designed to make  
your power chair traverse different types of terrain and obstacles while maintaining smooth operation. With STS,  
the spring-loaded drive wheels move in two directions—up for rolling over obstacles and down when  
encountering transitions.  
As the drive wheels come in contact with an obstacle, they are drawn upward. At the same time, the rear anti-tip  
wheels work in opposition to the drive wheels to eliminate the possibility of the chair losing traction. This creates  
a safer, more secure ride.  
STS also helps in day-to-day operating conditions. This unique suspension system helps to harness the motors’  
torque to make smoother transitions in speed during acceleration or deceleration.  
Manual Freewheel Levers  
For your convenience, your power chair is equipped with two manual freewheel levers mounted on the motors.  
Depending on which motors your power chair is equipped with, you will have one of two possible freewheel  
levers. See figures 8, 9, 10, or 11. These levers allow you to disengage the drive motors and maneuver the chair  
manually. You can manually push the power chair by the seatback or push the power base itself if the seat is  
removed.  
WARNING! Do not use the power chair while the drive motors are disengaged! Do not  
disengage the drive motors when the power chair is on an incline or decline, as the  
unit could roll on its own. Only engage the freewheel mode when on a level surface.  
WARNING! It is important to remember that when your power chair is in freewheel  
mode, the braking system is disengaged.  
To operate the manual freewheel levers:  
1. Push the manual freewheel lever down for freewheel mode (drive disengaged). See figure 8 or 10.  
2. Pull the manual freewheel lever up for drive mode (drive engaged). See figure 9 or 11.  
NOTE: If the lever is difficult to move in either direction, rock your power chair back and forth slightly. The  
lever should then move to the desired position.  
WARNING! Do not use the freewheel lever handles as tie-down points to secure this product.  
20  
Quantum R-4000  
Download from Www.Somanuals.com. All Manuals Search And Download.  
III. YOUR POWER CHAIR  
Figure 8. Freewheel Mode (Drive Disengaged) - Ham m er  
Motor  
Figure 9. Drive Mode (Drive Engaged) - Ham m er Motor  
Figure 11. Drive Mode (Drive Engaged) - Glide Motor  
Figure 10. Freewheel M ode (Drive Disengaged) - Glide  
M otor  
Quantum R-4000  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IV. ASSEMBLY  
Seat Installation  
It may be necessary to install the seat either prior to initial  
operation or after transporting your power chair.  
NOTE: If your power chair is equipped with a Specialty  
Seat, Synergy Seat, or a Synergy TRU-Balance 2 Power  
Positioning System, refer to the information provided in  
separate manuals.  
NOTE: Any nylon insert lock nut removed during the  
disassembly or adjustment of the power chair must be  
replaced with a new nut. Nylon insert lock nuts should not  
be reused as it may cause damage to the nylon insert,  
resulting in a less secure fit. Replacement nylon insert  
lock nuts are available at local hardware stores or  
through your Quantum Rehab Provider.  
WARNING! Do not pick up the seat frame by  
the armrests. They are free to pivot, and you  
may lose control of the seat if they do so.  
Figure 12. Seat Installation  
To install the seat:  
1. Set the trapeze bars to the desired height. To change the  
trapeze bar height, see V. “Comfort Adjustments.”  
2. Tilt the seat back, and slide the rear extrusion onto the  
rear trapeze bar. See figure 12.  
3. Lower the front extrusion onto the front trapeze bar  
until the seat locks into place.  
4. Flip the seat latch safety down. See figure 12.  
WARNING! Make sure the seat latch safety  
is flipped down before using your power  
chair.  
5. Install the controller into one of the armrests. See V.  
“Comfort Adjustments.”  
Figure 13. Controller Harness Routing - Synergy  
Seat  
6. Route the controller harness to the front or back of the  
power chair to the controller connector, ensuring that the  
harness cannot be pinched in the seat hinge. See figure 13.  
7. If the controller connector is located at the rear of the  
power chair, release the battery door latches and open  
the battery door. See figure 7.  
8. Plug the controller harness into the connector. See figure 6.  
9. Close the battery door if necessary.  
10. Secure the controller harness to the armrest receiver  
with one or more wire ties.  
MANDATORY! Prevent controller harness  
damage! Avoid routing the controller  
harness on the outside of the armrest pad.  
Route the harness under the armrest or  
toward the inside of the armrest pad. Use  
correct tie-down points for the controller  
harness to prevent the harness from  
getting caught in the drive tires, pinched in  
the seat frame, or damaged when passing  
through doorways.  
Figure 14. Controller Harness Routing W ire Tie  
Locations - Contour Seat  
22  
Quantum R-4000  
Download from Www.Somanuals.com. All Manuals Search And Download.  
V. COMFORT ADJUSTMENTS  
COMFORT ADJUSTMENTS  
After becoming familiar with your power chair’s operation, you may find the need to make some adjustments to  
increase your comfort, such as seat height and angle, armrest width, armrest angle and height, leg rest position,  
and controller position.  
NOTE: If your power chair is equipped with a Specialty Seat, Synergy Seating System, or TRU-Balance 2  
Power Positioning System, refer to the seat adjustment information contained in separate manuals. If your  
power chair is equipped with a contoured seating system, refer to the following information.  
WARNING! The center of gravity of your power chair was factory set to a position that meets the  
needs of the demographic majority of users. Your Quantum Rehab Provider has evaluated your  
power chair and made any necessary adjustments to suit your specific requirements. Do not  
change your seating configuration without first contacting Pride Mobility Products or your  
Quantum Rehab Provider.  
WARNING! Some power chair components are heavy. You may need assistance to lift or carry  
them. Please refer to the specifications table for specific component weights before you  
disassemble the power chair.  
WARNING! Remove the occupant from the power chair before making any adjustments.  
You may need the following to make comfort  
adjustments:  
metric/standard hex key set  
metric/standard socket set and ratchet  
adjustable wrench  
Seat Height and Seat Angle Adjustment  
The seat is attached to the power base through the UMS. See  
figure 12. You can change the seat height to one of three  
positions by raising the front and rear trapeze bars. If you  
raise or lower only one trapeze bar (front or rear), you can  
also change the seat base angle (dump).  
Figure 15. Seat Latch Safety  
NOTE: It is easier to raise/lower the trapeze bars with the  
seat removed.  
To change the seat height or seat angle:  
1. Power off the controller.  
BOLT AND  
NUT  
REAR TRAPEZE BAR  
BOLT AND  
NUT  
2. Make sure the power chair is in drive mode.  
3. If the controller connector is located at the rear of the  
power base, release the battery door latches and open the  
battery door.  
4. Disconnect the controller connector. See figure 6 or 7.  
5. Flip up the seat latch safety to release the seat from the  
front trapeze bar. See figure 15.  
6. Slide the seat forward and lift it off the power base. Set  
it aside.  
7. Remove the bolt and nuts from the rear trapeze bar. See  
figure 16.  
Figure 16. Rear Trapeze Bar Adjustm ent  
8. Raise or lower the rear trapeze bar to the desired position.  
9. Reinstall the bolt and nuts into the rear trapeze bar.  
Quantum R-4000  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
V. COMFORT ADJUSTMENTS  
10. Loosen the shroud fasteners and remove the front  
shroud from the power base.  
11. Remove the hardware from the front trapeze bar.  
12. Raise or lower the front trapeze bar to the desired position.  
NOTE: To change the angle, set either the front or rear  
trapeze bar higher or lower than the other.  
13. Reinstall the hardware into the front trapeze bar.  
14. Place the seat back onto the trapeze bars and flip down  
the seat latch safety.  
15. Reinstall the front shroud.  
16. Reconnect the controller.  
17. Close the battery door and secure the battery door  
latches if necessary.  
Seat Position  
You can move the seat forward or rearward by changing the  
extrusion mounting position.  
SEAT MOUNTING HOLES  
To change the position:  
1. Turn off the power to the controller.  
Figure 17. Seat Position Adjustm ent  
2. Make sure the power chair is in drive mode.  
3. Release the battery door latches and open the battery door  
if necessary.  
4. Disconnect the controller connector(s) from the power  
base. See figure 6.  
5. Remove the seat from the power base.  
6. Remove both extrusions from the bottom of the seat.  
7. Reposition the extrusions on a different set of mounting  
holes. You must move both extrusions the same number  
of holes either forward or backward. See figure 16.  
8. Fasten the extrusions back onto the bottom of the seat.  
9. Reinstall the seat.  
10. Reconnect the controller to the power base. See figure 6.  
11. Close the battery door and secure the latches if necessary.  
12. Secure the controller harness to the armrest with wire  
ties. See figure 14.  
Manual Recline Seatback Adjustment  
If your power chair is equipped with a reclining seat, you  
can adjust the seatback angle with the seatback release  
lever. The lever is located on the right side of the seat base.  
To adjust the recline angle:  
1. Pull up on the seatback release lever.  
2. Lean forward or backwards to the desired position.  
3. Release the lever.  
24  
Quantum R-4000  
Download from Www.Somanuals.com. All Manuals Search And Download.  
V. COMFORT ADJUSTMENTS  
Seatback Angle Adjustment  
If your power chair is equipped with an adjustable  
seatback, you can adjust it to four (4) different angles:  
90°, 102°, 105°, or 107°.  
JAM NUT  
ARMREST ANGLE  
ADJUSTING  
SCREW  
To adjust the seatback angle:  
1. Remove the adjusting screws from each seat hinge.  
See figure 18.  
2. Set the seatback at the desired angle.  
3. Reinstall the adjusting screws to each seat hinge  
and tighten.  
ARMREST HEIGHT  
ADJUSTING  
SETSCREWS  
Armrest Width Adjustment  
You can change each armrest’s width independently of  
the other.  
SEATBACK ANGLE  
ADJUSTING SCREW  
NOTE: Changing the armrest width may increase the  
overall width of your power chair.  
ARMREST KNOB  
To change the armrest width:  
1. Locate the two armrest knobs on each side of the  
armrest receiver bracket. See figure 18.  
2. Loosen the knobs.  
Figure 18. Seatback/Arm rest Adjustm ent  
3. Slide the armrests in or out to the desired width.  
4. Tighten the knobs.  
Armrest Angle Adjustment  
To change the armrest angle:  
1. Lift the armrest straight up so that it is perpendicu-  
lar to the floor. See figure 18.  
2. Loosen the jam nut.  
3. Turn the adjusting screw to lower the front of the  
armrest or to raise the front of the armrest.  
4. Tighten the jam nut to lock the adjusting screw into  
place.  
Armrest Height Adjustment  
To change the armrest height:  
1. Loosen the two setscrews located on the armrest  
receiver. See figure 18.  
2. Raise or lower the armrest to the desired height.  
3. Tighten the setscrews to secure the armrest.  
Quantum R-4000  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
V. COMFORT ADJUSTMENTS  
Controller Position  
You can move the controller in toward or out away  
from the armrest, or change the position of the control-  
ler for either left-hand or right-hand use.  
WARNING! Do not place the controller  
harness so that it can be pinched in the  
seat frame or the power base frame.  
CONTROLLER BRACKET  
SETSCREW  
To extend the controller:  
1. Flip up the armrest so it is perpendicular to the floor.  
2. Loosen the setscrew on the controller bracket. See  
figure 19.  
3. Slide the controller into or out of the armrest to the  
desired position.  
4. Tighten the setscrew to secure the controller.  
NOTE: If your power chair is equipped with a Spe-  
cialty Seat, Synergy Seat, or TRU-Balance Power  
Positioning System, loosen the setscrews in the  
mounting block, slide the controller in or out to the  
desired position, then tighten the setscrews. See fig-  
ure 20.  
Figure 19. Underside of Arm rest  
To change the controller position:  
1. Turn off the power to the controller.  
2. Release the battery door latches and open the bat-  
tery door if necessary.  
MOUNTING BLOCK  
MOUNTING SCREWS  
3. Unplug the controller connector from the power base.  
4. Remove any wire ties securing the controller harness  
to the armrest.  
5. Flip up the armrest so it is perpendicular to the floor.  
6. Loosen the setscrew on the controller bracket.  
7. Slide the controller out of the armrest.  
8. Loosen the setscrew in the other armrest.  
9. Place the controller in the other armrest.  
10. Tighten the setscrew to secure the controller.  
11. Route the controller harness to the front or back of  
the power base and plug in the controller. See fig-  
ure 6 or 7.  
SETSCREWS  
Figure 20. Adjusting Controller Position (Standard Seat)  
12. Close the battery door and secure the latches if nec-  
essary.  
13. Secure the controller harness to the armrest with  
wire ties. See figure 14.  
NOTE: If your power chair is equipped with a Spe-  
cialty Seat, Synergy Seat, or TRU-Balance Power  
Positioning System, loosen the mounting screws in  
the mounting block, transfer the mounting block and  
controller to the opposite armrest, and tighten the  
mounting screws. See figure 20 .  
26  
Quantum R-4000  
Download from Www.Somanuals.com. All Manuals Search And Download.  
V. COMFORT ADJUSTMENTS  
Anti-Tip Wheels  
The anti-tip wheels are designed to give your power chair increased stability on rough surfaces. The anti-tip wheels  
are preset at the factory for smooth surfaces or indoor use only. If you plan on using your power chair on rough  
surfaces, it may be necessary to adjust the anti-tip wheels to better suit your needs. The anti-tip wheels may need  
adjustment if either of the following occur:  
When accelerating, your power chair tips rearward excessively.  
The anti-tip wheels constantly rub the ground.  
WARNING! Consult your Quantum Rehab Provider before attempting to change the anti-tip wheel  
height! Changing the anti-tip wheel height affects handling under deceleration!  
WARNING! The higher you raise the anti-tip wheels, the more you increase your power chair’s  
tendency to tilt rearward when accelerating. You can compensate for this by having your  
Quantum Rehab Provider make a small adjustment to the pre-programmed acceleration setting  
in the controller or by adjusting the seat assembly.  
WARNING! The anti-tip wheels may cause trouble when ascending or descending a curb if they  
are not adjusted correctly. Contact your Quantum Rehab Provider for more information.  
To adjust the anti-tip wheels:  
1. Loosen bolt A. See figure 21.  
2. Remove bolt B.  
3. Raise or lower the anti-tip wheel by 0.50 in. (1.25  
cm) or 1 in. (2.54 cm) increments by aligning the  
appropriate adjustment holes. See figure 21.  
4. Insert bolt B into the appropriate hole for the  
desired anti-tip height and tighten.  
5. Tighten bolt A.  
6. Raise or lower the other anti-tip wheel so that it  
is at the same height.  
PROHIBITED! Do not remove the  
anti-tip wheels.  
ANTI-TIP WHEEL  
BRACKET  
NOTE: Each drive tire must be inflated to the psi/  
bar/kPa rating indicated on the tire in order for the  
BOLT A  
anti-tip wheels to be properly adjusted. The user  
must also be seated in the power chair in order to  
ANTI-TIP WHEEL  
properly adjust the anti-tip wheels.  
BOLT B  
Figure 21. Anti-Tip W heel Assem bly  
Quantum R-4000  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VI. BATTERIES AND CHARGING  
BATTERIES AND CHARGING  
The Quantum R-4000 uses two long-lasting, 12-volt, deep-cycle batteries. These batteries are sealed and mainte-  
nance free. Since they are sealed, there is no need to check the electrolyte (fluid) level. Deep-cycle batteries are  
designed to handle a longer and deeper discharge. Though they are similar in appearance to automotive batteries,  
they are not interchangeable. Automotive batteries are not designed to handle a long, deep discharge, and also are  
unsafe for use in power chairs.  
MANDATORY! Battery posts, terminals, and related accessories contain lead and  
lead compounds. Wear goggles and gloves when handling batteries and wash hands  
after handling.  
WARNING! Contact your Quantum Rehab Provider if you have any questions regarding  
the batteries in your power chair.  
PROHIBITED! Always use two batteries of the exact same type, chemistry, and amp-  
hour (Ah) capacity. Refer to specifications table in this manual and in the manual  
supplied with the battery charger for recommended type and capacities.  
Charging the Batteries  
The battery charger is essential in providing long life for your power chair batteries. It is designed to optimize  
your power chair’s performance by charging the batteries safely, quickly, and easily. The battery charging system  
consists of the battery charger and the charger circuit fuse.  
PROHIBITED! Removal of grounding prong can create electrical hazard. If necessary,  
properly install an approved 3-pronged adapter to an electrical outlet having 2-  
pronged plug access.  
PROHIBITED! Never use an extension cord to plug in your battery charger. Plug the  
charger directly into a properly wired standard electrical outlet.  
PROHIBITED! Do not allow unsupervised children to play near the power chair while  
the batteries are charging. Pride recommends that you do not charge the batteries  
while the power chair is occupied.  
MANDATORY! Read the battery charging instructions in this manual and in the  
manual supplied with the battery charger before charging the batteries.  
WARNING! Explosive gases may be generated while charging the batteries. Keep the  
power chair and battery charger away from sources of ignition such as flames or  
sparks and provide adequate ventilation when charging the batteries.  
WARNING! You must recharge your power chair’s batteries with the supplied off-  
board battery charger. Do not use an automotive-type battery charger.  
WARNING! Inspect the battery charger, wiring, and connectors for damage before  
each use. Contact your Quantum Rehab Provider if damage is found.  
WARNING! Do not attempt to open the battery charger case. If the battery charger  
does not appear to be working correctly, contact your Quantum Rehab Provider.  
WARNING! If the battery charger is equipped with cooling slots, then do not attempt  
to insert objects through these slots.  
WARNING! If your battery charger has not been tested and approved for outdoor use,  
then do not expose it to adverse or extreme weather conditions. If the battery  
charger is exposed to adverse or extreme weather conditions, then it must be  
allowed to adjust to the difference in environmental conditions before use indoors.  
Refer to the manual supplied with the battery charger for more information.  
28  
Quantum R-4000  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VI. BATTERIES AND CHARGING  
To charge the batteries using the off-board charger:  
1. Position the front of your power chair next to a standard  
electrical outlet.  
2. Be certain the controller power is turned off and the free-  
wheel levers are in the drive position. See III. “Your Power  
Chair.”  
3. Plug the off-board charger into the off-board charger/pro-  
gramming socket on the controller. See figure 22.  
4. Plug the off-board charger into the electrical outlet.  
NOTE: The LED lights on the charger indicate different  
charger conditions at various times: charger power on,  
charging in progress, and charging complete. Refer to the  
manual supplied with the charger for a complete explanation  
of these indicators.  
5. When the batteries are fully charged, unplug the off-board  
charger from the electrical outlet and then from the controller.  
Figure 22. Battery Charging  
Battery Break-in  
To break in new batteries for maximum efficiency:  
1. Fully recharge any new battery prior to its initial use. This brings the battery up to about 90% of its peak  
performance level.  
2. Operate your power chair throughout the house and grounds. Move slowly at first, and do not travel too far  
until you become accustomed to the controls and break in the batteries.  
3. Give the batteries another full charge of 8 to 14 hours and operate your power chair again. The batteries will  
now perform at over 90% of their potential.  
4. After four or five charging cycles, the batteries will top off at 100% charge and last for an extended period.  
Frequently Asked Questions (FAQs)  
How does the charger work?  
The battery charger takes the standard electrical outlet voltage (alternating current) and converts it to direct  
current. When the battery voltage is low, the charger works harder to charge the battery. As the battery voltage  
approaches full charge, the charger doesn’t work as hard to complete the charging cycle. When the battery is fully  
charged, the amperage from the charger is nearly at zero. This is how the charger maintains a charge but does not  
overcharge the battery.  
Can I use a different battery charger?  
You should use the charger supplied with the power chair. It is the safest, most efficient tool to charge the  
batteries. We do not recommend using other types of chargers (e.g., an automotive battery charger).  
NOTE: Your power chair’s charger will not operate after the batteries have been discharged to nearly zero  
voltage. If this happens, call your Quantum Rehab Provider for assistance.  
Quantum R-4000  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
V I. B A TTER IES A ND C HA R GING  
How often must I charge the batteries?  
Many factors come into play when deciding how often to charge the batteries. You may use your power chair all  
day on a daily basis or you may not use it for weeks at a time.  
Daily Use  
If you use your power chair on a daily basis, charge the batteries as soon as you are finished using your power  
chair. Your power chair will be ready each morning to give you a full day’s service. It is recommended that  
you charge the batteries 8 to 14 hours after daily use.  
Infrequent Use  
If you use your power chair infrequently (once a week or less), you should charge the batteries at least once  
per week for 12 to 14 hours.  
NOTE: Keep your batteries fully charged and avoid deeply discharging your batteries. Refer to the manual  
supplied with the battery charger for charging instructions.  
How can I get maximum range or distance per charge?  
Rarely do you have an ideal driving situation such as smooth, flat, hard terrain with no wind, hills, or curves. More  
often you are presented with hills, pavement cracks, uneven and loosely packed surfaces, curves, and wind. All  
of these factors will affect the distance or running time per battery charge. Below are a few suggestions for  
obtaining the maximum range per charge:  
Always charge the batteries fully prior to your trip.  
Plan your trip in advance to avoid inclines if possible.  
Limit baggage weight to essential items.  
Try to maintain an even speed and avoid stop-and-go driving.  
What type of batteries should I use?  
We recommend deep-cycle batteries that are sealed and maintenance free. Both AGM and Gel-Cell are deep-cycle  
batteries that are similar in performance.  
WARNING! Corrosive chemicals contained in batteries. Use only AGM or Gel-Cell  
batteries to reduce the risk of leakage or explosive conditions.  
Why do my new batteries seem weak?  
Deep-cycle batteries employ a much different chemical technology than that used in car batteries, nickel-cadmium  
(nicads), or in other common battery types. Deep-cycle batteries are specifically designed to provide power, drain  
down their charge, and then accept a relatively quick recharge. AGM and Gel-Cell batteries should be charged as  
often as possible. They do not have a “memory” like nickel-cadmium batteries.  
We work closely with our battery manufacturer to provide a battery that best suits your power chair’s specific  
demands. Fresh batteries arrive regularly at Pride and are promptly shipped with a full charge. During shipping,  
the batteries encounter temperature extremes that may influence initial performance. Heat robs the charge from  
the battery, and cold slows the power available and extends the time needed to recharge the battery (just as with  
a car battery).  
It might take a few days for the temperature of the battery to stabilize and adjust to its new ambient temperature.  
More importantly, it will take a few “charging cycles” (a partial drain— then a full recharge) to establish the  
critical chemical balance that is essential to the battery’s peak performance and long life. It will be well worth it  
to take the time to break in your battery properly.  
30  
Quantum R-4000  
Download from Www.Somanuals.com. All Manuals Search And Download.  
V I. B A TTER IES A ND C H A R G ING  
How can I ensure maximum battery life?  
A fully charged deep-cycle battery will provide reliable performance and extended battery life. Keep your power  
chair’s batteries fully charged whenever possible. Batteries that are regularly and deeply discharged, infrequently  
charged, or stored without a full charge may be permanently damaged, causing unreliable power chair operation  
and limited battery life.  
NOTE: The useful life of a battery is quite often a reflection of the care it receives.  
How should I store my power chair and its batteries?  
If you do not use your power chair regularly, we recommend maintaining battery vitality by charging the batteries  
at least once per week.  
If you do not plan on using your power chair for an extended period, fully charge the batteries prior to storage.  
Disconnect the battery harnesses and store the power chair in a warm, dry environment. Avoid temperature  
extremes, such as freezing and excessively hot conditions, and never attempt to charge a frozen battery. A cold or  
frozen battery should be warmed for several days prior to recharging.  
What about public transportation?  
AGM and Gel-Cell batteries are designed for application in power chairs and other mobility vehicles, allowing  
safe transport on aircraft, buses, and trains, as there is no danger of spillage or leakage. We suggest you contact  
the carrier’s ticket counter in advance to determine that carrier’s specific requirements.  
What about shipping?  
If you wish to use a freight company to ship your power chair to your final destination, repack your power chair  
in the original shipping container, and ship the batteries in separate boxes.  
Quantum R-4000  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VII. CARE AND MAINTENANCE  
CARE AND MAINTENANCE  
Your Quantum R-4000 is a sophisticated power chair. Like any motorized vehicle, it requires routine maintenance  
checks. You can perform some of these checks, but others require assistance from your Quantum Rehab Provider.  
Preventive maintenance is very important. If you follow the maintenance checks in this section as scheduled, you  
can help ensure that your power chair gives you years of trouble-free operation. If you have any doubt as to your  
power chair’s care or operation, contact your Quantum Rehab Provider.  
WARNING! Do not service the power chair when the seat is occupied.  
Your power chair, like most electrical equipment, is susceptible to damage from the elements. Avoid damp areas  
of any kind.  
WARNING! Direct or prolonged exposure to water or dampness could cause the power  
chair to malfunction electronically and mechanically. Water can cause electrical  
components to corrode and the chair’s frame to rust. Power chairs should be  
examined periodically for signs of corrosion caused by water exposure, bodily fluids  
exposure, or incontinence. Damaged components should be replaced or treated  
immediately.  
Should your power chair come in contact with water:  
1. Dry your power chair as thoroughly as possible with a towel.  
2. Allow your power chair to sit in a warm, dry place for 12 hours to allow unseen water to evaporate.  
3. Check the joystick operation and the brakes before using your power chair again.  
4. If any inconsistencies are found, take your power chair to your Quantum Rehab Provider. Power chairs that  
are frequently exposed to sources of water, such as incontinence, should be inspected often for corrosion and  
electronic components may need to be replaced frequently.  
Temperature  
Some of the parts of your power chair are susceptible to extreme changes in temperature. Always keep your  
power chair between the temperatures of 18°F (-8°C) and 122°F (50°C).  
In extremely cold temperatures the batteries may freeze. The specific temperature at which they freeze  
depends on a number of factors, such as battery charge, usage, and composition of the batteries (e.g., AGM or  
Gel-Cell).  
Temperatures above 122°F (50°C) may cause your power chair to operate at a reduced speed. This reduced  
speed is a safety feature built into the controller that helps prevent damage to the motor and other electrical  
components.  
General Guidelines  
Avoid knocking or bumping the controller, especially the joystick.  
Avoid prolonged exposure of your power chair to extreme conditions, such as heat, cold, or moisture.  
Keep the controller clean.  
Check all connectors to ensure that they are all tight and secured properly.  
Maintain but do not exceed the psi/bar/kPa air pressure rating indicated on the tire.  
WARNING! Maintain but do not exceed the psi/bar/kPa air pressure raiting indicated on the tire for  
pneumatic tires. Do not underinflate or overinflate your tires. Low pressure may result in loss of  
control, and overinflated tires may burst. Overinflating tires can cause them to explode.  
WARNING! Do not use a high pressure hose to inflate your tires.  
Use a rubber conditioner on the tire sidewalls to help preserve them.  
WARNING! Never use a rubber conditioner on the tread area of the tires; doing so may make the  
tires slippery and cause your power chair to skid.  
32  
Quantum R-4000  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VII. CARE AND MAINTENANCE  
All wheel bearings are prelubricated and sealed. They require no subsequent lubrication.  
The body shroud has been sprayed with a clear sealant coating. You can apply a light coat of car wax to help  
it retain its high-gloss appearance.  
Check all electrical connections. Make sure they are tight and are not corroded. Batteries must sit flat within  
battery boxes, with the battery terminals facing the top of the battery box. Refer to the battery wiring label for  
the correct wiring layout.  
WARNING! Even though the power chair has passed the necessary testing  
requirements for ingress of liquids, you should keep electrical connections away  
from sources of dampness, including direct exposure to water or bodily fluids and  
incontinence. Check electrical components frequently for signs of corrosion and  
replace as necessary.  
Daily Checks  
With the controller turned off, check the joystick. Make sure it is not bent or damaged and that it returns to the  
neutral position when you release it. Check the rubber boot around the base of the joystick for damage. Visu-  
ally inspect the boot. Do not handle or try to repair it. See your Quantum Rehab Provider if there is a problem.  
Visually inspect the controller harness. Make sure that it is not frayed, cut, or has any wires exposed. See your  
Quantum Rehab Provider if there is a problem.  
Check for flat spots on solid tires. Flat spots could adversely affect stability.  
Inspect the armrests for loose hardware, stress points, or damage. See your Quantum Rehab Provider if there  
is a problem.  
Weekly Checks  
Disconnect and inspect the controller from the power base. Look for corrosion. Contact your Quantum Rehab  
Provider if necessary.  
Ensure that all parts of the controller system are securely fastened to your power chair. Do not overtighten any  
screws.  
Check for proper tire inflation. If a tire does not hold air, see your authorized Pride Provider for replacement  
of the tube.  
Check the brakes. This test should be carried out on a level surface with at least three feet of clearance around  
your power chair.  
To check the brakes:  
1. Turn on the controller and turn down the speed level of your power chair.  
2. After one second, check the battery condition meter. Make sure that it remains on.  
3. Slowly push the joystick forward until you hear the electric brakes click. Immediately release the joystick.  
You must be able to hear each electrical brake operating within a few seconds of joystick movement. Repeat  
this test three times, pushing the joystick rearward, then left and then right.  
Monthly Checks  
Check for drive tire wear. See your Quantum Rehab Provider for repair.  
Check the caster wheels for wear. Replace them as necessary.  
Check the caster forks for damage or fluttering which indicates that they may need to be adjusted or have the  
bearings replaced. See your Quantum Rehab Provider for repair.  
Keep your power chair clean and free of foreign material, such as mud, dirt, hair, food, drink, etc.  
Yearly Checks  
Take your power chair to your Quantum Rehab Provider for yearly maintenance, especially if you use your power  
chair on a regular basis. This helps ensure that your power chair is functioning properly and helps prevent future  
complications.  
Quantum R-4000  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VII. CARE AND MAINTENANCE  
Storage  
Your power chair should be stored in a dry place, free from temperature extremes. When storing, disconnect the  
batteries from the power chair. See VI. “Batteries and Charging.”  
WARNING! If you fail to store the unit properly, the frame can rust and the electronics can be  
damaged.  
Batteries that are regularly and deeply discharged, infrequently charged, stored in extreme temperatures, or stored  
without a full charge may be permanently damaged, causing unreliable performance and limited service life. It is  
recommended that you charge the batteries periodically throughout periods of prolonged storage to ensure proper  
performance.  
You may wish to place several boards under the frame of your power chair to raise it off of the ground during  
periods of prolonged storage. This takes the weight off the tires and reduces the possibility of flat spots developing  
on the areas of the tires contacting the ground.  
Disposal of Your Power Chair  
Your power chair must be disposed of according to applicable local and national statutory regulations. Contact  
your local waste disposal agency or Quantum Rehab Provider for information on proper disposal of power chair  
packaging, metal frame components, plastic components, electronics, and batteries.  
Cleaning and Disinfection  
Use a damp cloth and mild, non-abrasive cleanser to clean the plastic and metal parts of your power chair.  
Avoid using products that may scratch the surface of your power chair.  
If necessary, clean your product with an approved disinfectant. Make sure the disinfectant is safe for use on  
your product before application.  
WARNING! Follow all safety instructions for the proper use of the disinfectant and/or cleaning  
agent before applying it to your product. Failure to comply may result in skin irritation or  
premature deterioration of upholstery and/or power chair finishes.  
WARNING! Never hose off your power chair or place it in direct contact with water. Your power  
chair has a painted, ABS plastic body shroud that allows it to be easily wiped clean with a damp  
cloth.  
WARNING! Never use any chemicals to clean a vinyl seat, as they may cause the seat to become  
slippery or dry out and crack. Use soapy water and dry the seat thoroughly.  
Wheel Replacement  
If you have pneumatic tires and you have a flat tire, you can replace the tube. If your chair is equipped with a solid  
tire insert, then you must replace the entire wheel assembly. Replacement tires, tubes, and wheel assemblies are  
readily available through your Quantum Rehab Provider.  
WARNING! The wheels on your power chair should only be serviced or replaced by a Quantum  
Rehab Provider or a qualified technician.  
WARNING! Be sure that the power to the controller is turned off and the power chair is not in  
freewheel mode before performing this procedure.  
WARNING! When changing a tire, remove only the five drive wheel lug nuts, then remove the  
wheel. If any further disassembly is required, deflate the tire completely or it may explode.  
34  
Quantum R-4000  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VII. CARE AND MAINTENANCE  
TIRE  
TUBE  
SCREWS  
FRONT RIM HALF  
WHEEL HUB  
REAR RIM HALF  
LUG NUT  
Figure 23. Quantum R-4000 Drive W heel  
Figure 24. Quantum R-4000 Drive W heel Disassem bled  
Follow these easy steps for a quick and safe repair for both pneumatic and solid tires:  
1. Turn off the power to the controller.  
2. Set the power chair up on blocks.  
3. If you are changing a pneumatic tire, completely deflate it before removing the wheel.  
4. Remove the five (5) lug nuts from the wheel hub. See figure 23.  
5. Remove the wheel from the hub.  
6. Remove the screws and separate the front and rear rim. See figure 24.  
7. Remove the old tube from the pneumatic tire and replace it with a new tube or replace the entire assembly if  
it is a solid tire.  
8. Screw together the two rim halves.  
9. Slide the wheel back onto the hub.  
10. Reinstall the five (5) lug nuts and tighten.  
11. Inflate the pneumatic tire to the psi/bar/kPa air pressure rating indicated on each tire.  
12. Remove the power chair from the blocks.  
Battery Replacement  
A battery wiring diagram is printed on a decal located on the battery door. See figure 25. Refer to the specifications  
table in III. “Your Power Chair” for correct battery specifications.  
MANDATORY! Battery posts, terminals, and related accessories contain lead and  
lead compounds. Wear goggles and gloves when handling batteries and wash hands  
after handling.  
WARNING! Do not replace battery when seat is occupied.  
WARNING! The batteries on your power chair should only be serviced or replaced by  
a Quantum Rehab Provider or a qualified technician.  
WARNING! Power chair batteries are heavy. See specifications table. If you are  
unable to lift that much weight, be sure to get help. Use proper lifting techniques and  
avoid lifting beyond your capacity.  
WARNING! Do not mix old and new batteries. Always replace both batteries at the  
same time.  
Quantum R-4000  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VII. CARE AND MAINTENANCE  
To replace the batteries:  
1. Turn off the power to the controller.  
2. Push the manual freewheel lever in or up for drive mode.  
3. Remove or rotate the leg rests to the side.  
4. Release the battery door latches at the back of the power chair.  
5. Locate the battery quick disconnects on the frame and  
disconnect both of them. See figure 25.  
6. Remove the batteries from the power base.  
7. Disconnect the battery wiring harness from each battery.  
8. Reinstall the battery wiring harness on each new battery.  
Make sure that you connect the red wire to the positive (+)  
battery terminal and the black wire to the negative (-)  
battery terminal.  
WARNING! Make sure you tighten the fasteners  
so that the connections are secure.  
9. Place the batteries back into the power base.  
10. Connect the battery quick disconnects according to the  
battery wiring diagram label located on the frame. See  
figure 25.  
Figure 25. Battery W iring Diagram  
11. Reconnect the battery door latches.  
12. Reinstall or rotate the leg rests back to position.  
When to See Your Quantum Rehab Provider for Service  
The following symptoms could indicate a serious problem with your power chair. If necessary, contact your  
Quantum Rehab Provider. When calling, have the model number, serial number, nature of the problem, and the  
trouble code if available.  
Motor noise  
Frayed harnesses  
Cracked or broken connectors  
Uneven wear on any of the tires  
Jerky motion  
Pulling to one side  
Bent or broken wheel assemblies  
Does not power up  
Powers up, but does not move  
Corrective Maintenance  
If the battery condition meter does not light up when you turn on the power:  
Check the harness connections. Make sure they are tight.  
Check the circuit breaker. Reset it if necessary.  
Check the battery connections.  
If the above conditions prove normal, you can load test the batteries with a battery load tester. These testers are  
available at automotive parts stores. Disconnect both batteries before load testing and follow the directions that  
come with the load tester. If either one of the batteries fails the load test, replace both of them. If your power chair  
still does not power up, contact your Quantum Rehab Provider.  
36  
Quantum R-4000  
Download from Www.Somanuals.com. All Manuals Search And Download.  
APPENDIX I - SPECIFICATIONS  
SPECIFICATIONS  
Full suspension - Sport Trac  
Suspension:  
Drive Wheels:  
14 in. (35.5 cm), center-mounted, pneumatic or solid available  
Caster Wheels:  
Anti-tip Wheels:  
9 in. (23 cm), front articulating, pneumatic or solid available (8 in. {20.32 cm} are optional)  
4 in. (10 cm) solid, rear-mounted  
1,4,5  
Maximum Speed:  
Quantum R-4000 3S, 3SP, and 3MP: Up to 6 mph (9.656 km/h)  
Quantum R-4400 4S, 4SP, and 4MP: Up to 8 mph (12.875 km/h)  
Brakes:  
“Intelligent Braking” electronic regenerative, disc park brake  
2
Ground Clearance:  
See figure 26.  
See figure 26.  
2
Turning Radius:  
2
Overall Size:  
Length: See figure 26.  
Width: See figure 26.  
Drivetrain:  
Two motor, rear-wheel drive  
3
Batteries:  
Two 12-volt 70 AH Group 24 batteries (Group 34 optional)  
1,5,6  
Range:  
Up to 20 miles (32 km)  
8-amp, off-board  
Battery Charger:  
Weight Capacity:  
Component Weights:  
300 lbs. (136 kg)  
Base: 144 lbs. (65.32 kg)  
Batteries: 53 lbs. (24 kg) each (Group 24)  
43 lbs. (19.5 kg) each (Group 34)  
1
2
Varies with base model, user weight, terrain type, battery amp hour rating (Ah), battery charge, battery condition, motors,  
controller type, tire type, and tire condition.  
Due to manufacturing tolerances and continued product improvement, this specification can be subject to variance of (+  
or – ) 3%.  
AGM or Gel-Cell type required. See VI. “Batteries and Charging.”  
Quantum R-4000 Group 3 equipped with 5 mph Glide motors standard, 6 mph motors optional. Quantum R-4000 Group  
4 equipped with 6 mph motors standard, 8 mph High-speed Hammer motors optional.  
This specification can be subject to variance of (+ or – ) 10%.  
Tested in accordance with ASNI/RESNA, WC Vol 2, Section 4 & ISO 7176-4 standards. Results derived from theoretical  
calculation based on battery specifications and drive system performance. Test conducted at maximum weight capacity.  
3
4
5
6
NOTE: This product conforms to all applicable ANSI-RESNA testing requirements and ISO 7176 EN12184 stan-  
dards. All specifications subject to change without notice.  
Quantum R-4000  
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
APPENDIX I - SPECIFICATIONS  
LENGTH (WITHOUT FRONT RIGGINGS)  
33 in. (83.82 cm)  
23.5 in. (59.69 cm)  
WIDTH  
25.375 in. (64.45 cm)  
TURNING RADIUS  
(WITHOUT FRONT RIGGINGS)  
GROUND CLEARANCE  
2.625 in. (6.67 cm)  
Figure 26. Quantum R-4000 Dim ensions and Ground Clearance  
38  
Quantum R-4000  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTES  
Quantum R-4000  
39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
N O TES  
40  
Quantum R-4000  
Download from Www.Somanuals.com. All Manuals Search And Download.  
N O TES  
Quantum R-4000  
41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
N O TES  
42  
Quantum R-4000  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Quality Control - Quantum R-4000 Series  
Inclusion of all Parts  
Joystick Serial Number  
Controller Serial Number  
Left Motor Serial Number  
Right Motor Serial Number  
Fit and Finish  
Performance  
Pride keeps a more detailed report on file at the factory.  
Date Inspected  
Inspector  
*I NFMANU3576*  
Product Serial Number  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Q Logic Network Router IB0056101 00 G02 User Guide
Radio Shack Computer Keyboard Keyboard User Guide
RCA Cordless Telephone 26971 User Guide
RCA Microwave Oven RMW747 User Guide
Rotel Stereo Amplifier RC 1090 User Guide
Runco Car Video System WP 42HD User Guide
Ryobi Outdoor Trimmer CS30, SS30, BC30 User Guide
Samsung Home Theater System HE10T User Guide
Scotsman Ice Ice Maker C0330 User Guide
Sennheiser Headphones E 180 User Guide