QTM300CA USER'S GUIDE
Cloning Adapter for the QT3xx family of QProx™ ICs
The QTM300CA is a cloning
Description
adapter designed to interface
between any QT3xx 8-pin
sensor IC (QT300, QT310,
QT320) and a PC or other
host device.
This adapter permits the
designer to upload settings
from a PC into the target chip
or to read the settings inside a
chip. The supplied cable
allows the board to plug
directly into both the E3A and
E3B eval boards.
For production use, the target
PCB can have a similar connector which allows the QTM300CA to upload settings on
a mass basis. The cloning process takes under 1 second to complete.
The QTM300CA’s eeprom memory permits the board to be used as a stand-alone
cloning adapter once it is programmed from a PC with the desired setups. An onboard
socket also allows the user to program QT3xx parts individually. The QTM300CA can
also be used to read back and verify the settings in QT3xx parts.
For the QT300 continuous IC, this adapter also provides the additional functionality of
interfacing to that device’s SPI port to download signal data, which can then be
observed directly on the PC in real time using QT3View software.
QT3View PC software is included, and updates can be downloaded from Quantum’s
web site.
You should find the following materials included with your QTM300CA:
ꢀ 1x QTM300CA board
ꢀ 1x RS232 DB-9 serial extension cable
ꢀ 1x RC02 (IDC to IDC) clone cable
Materials
Provided
RC01 (IDC to 7 way, for older E3B boards) is available on request.
ꢀ 1x 9V battery
ꢀ 1x QT3View user guide
You will also need: A PC running any recent version of Windows (98, 98SE, NT4,
2000, XP) upwards, with a free serial port (Com 1 or Com 2), and if desired a bench
power supply to replace the battery (9 - 15V DC) for long term use.
lq
1
QTM300CA/R1.02 25.09.03
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 1 - Board Layout
Board Details
Power Switch
Selects between the onboard battery (right) or an external power source (left).
Power
Connector
For external power, between +8 to +20 Volts DC. Power should be free from switching
noise and short-term fluctuations for best performance. A 9V battery is fine for short
term use, but make sure the battery does not drain to below 8V or erroneous operation
can occur.
RS232
Connector
Provides communications between the QTM300CA and the PC. It allows the user to
upload or download setups from the cloning adapter to the target QT3xx. The cable to
the PC should be an ‘extension’ type (wired 1:1), included.
Cloning
Ribbon Cable
Connects to the target board and can be connected whether or not the target is
powered. The cable has a stripe on one side; care should be taken not to reverse this
cable. This stripe aligns with pin 1 (white square) of the E3A or E3B board header.
IC Programming
Socket
The QTM300CA can be used to program QT3xx chips onboard. The board can accom-
modate either a ZIF socket or a SMT socket (when used with appropriate adapters, not
included - see Figure 1 above and ZIF Info, Page 11).
In Stand-alone mode, once the chip to be programmed is inserted, the QTM300CA will
detect the chip part number and display it on the ‘DEV0 and DEV1’ LEDs (see below).
Program
Button
If a QT3xx chip has been auto-detected, this button will clone Setups data from the
QTM300CA to the chip. The ‘PROG’ LED (see next section) indicates the programming
result. The QTM300CA can store three sources of data, one for each part type. The
correct source will be used to program the detected part.
lq
3
QTM300CA/R1.02 25.09.03
Download from Www.Somanuals.com. All Manuals Search And Download.
Status LEDs
PC
Indicates if QT3View software is communicating with the QTM300CA.
This LED will turn off five seconds after communications have stopped.
DEV0, DEV1
Displays the chip type connected via the ribbon cable or in the onboard socket:
DEV1
DEV0
Device
None
-
-
-
On
-
QT300
QT310
QT320
On
On
On
PROG
Indicates the programming status of the target chip in Stand-alone mode.
The PROG LED will light during the cloning process in Stand-alone mode.
Afterwards the LED will flash on/off 3 times to indicate completion:
Fast flashing: (0.1s between flashes) the clone process was a success.
Slow flashing: (1s between flashes) the clone process failed.
If the QTM300CA is not in communication with QT3View software, the PROG LED will
flash on and off.
lq
4
QTM300CA/R1.02 25.09.03
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 2 - QT3View Screen
QT3View Operation
Part Selector
Tabs
Allows you to view and communicate with the right part. Any serial data transfer will
involve only the active tab. The software will auto-recognize the type of chip connected
to the QTM300CA and choose the right tab for you.
If no chip is installed, the tab can be manually selected to allow data transfers with the
QTM300CA’s onboard e2prom.
File | Open
File | Save
Restores a config file saved by (File | Save). All three part selector configurations (tabs)
will be restored by this action.
Saves all three part selector configurations to disk in a single file, to a file name of your
choice.
Sensor | CommPort
Selects the desired PC serial port. Com1 is selected by default when the software is
first started, if it is available.
2
Sends the Setups of the open tab to the QTM300CA’s onboard e prom for use
in later cloning. Repeat this step with each selector tab opened in turn, to
upload Setups for multiple part types.
Sensor | Upload
to Adapter
Sensor | Download
from Adapter
2
Reads the Setups from the e prom of the QTM300CA into the currently open
selector tab. Only the data for the open tab is read. Repeat this step with each
tab open in turn to read in all the configurations stored in the QTM300CA.
Sensor | Upload
to Chip
2
Sends the Setups from the currently open selector tab directly to the e prom
of a QT3xx chip. Data stored in the QTM300CA is not affected by this opera-
tion. The open tab must coincide with the connected chip type.
2
Reads the Setups directly from the e prom of a connected QT3xx chip into the
corresponding selector tab. Data stored in the QTM300CA is not affected by
this operation.
Sensor | Download
from Chip
lq
5
QTM300CA/R1.02 25.09.03
Download from Www.Somanuals.com. All Manuals Search And Download.
Setup and
Guideline Boxes
These boxes show and modify the available Setups for the chosen chip.
Timing related values have no meaningful unit of measure unless interpreted together
with the device supply voltage and Sleep Cycles. To aid in understanding the effects of
these Setups, ‘Guideline’ boxes are used next to timing related Setups to give an
estimate of the result in seconds.
Guideline boxes cannot be modified, they only exist to inform you of the effects of the
timing Setups. Guideline numbers will change if Sleep Cycles, Burst Length, or Voltage
are changed, because QT3xx device timings vary with these things.
The QTM300CA and QT3View cannot directly measure the effects of Setup changes or
supply voltage changes. The numbers presented are reasonable estimates only.
Hardware
Parameter
Entry
Allows you to enter the expected chip supply voltage and the burst length (total of both
channels together in the case of the QT320) in order to allow Guideline boxes to show
reasonably accurate timing values. The QTM300CA cannot measure these parameters.
To measure the burst length, use an oscilloscope with a 750K series resistor on the
probe tip to limit loading, and measure on either SNS pin of the QT chip from the start
of the first pulse to the end of the last.
QT320: Add together the burst length times of both channels when entering the number
for this chip.
Status Bar
Display
The status bar at the bottom shows the serial port and connection status.
Possibilities are:
Serial Port Status:
- Off Line
- COM1: 57600 N 8 1
- COM2: 57600 N 8 1
Connection Status: - Status: Clone connected
- Status: Clone & QT300 connected
- Status: Clone & QT310 connected
- Status: Clone & QT320 connected
- Status: No Clone
lq
6
QTM300CA/R1.02 25.09.03
Download from Www.Somanuals.com. All Manuals Search And Download.
Cloning Directly to a Chip
You can read and clone back information to a QT3xx chip directly from your PC without involving the onboard
stand-alone memory of the QTM300CA. Here’s how....
Hook everything up:
Step 1
ꢀ
Connect the serial cable from the PC to the QTM300CA.
Connect the QTM300CA’s cloning cable to the target PCB, or plug a QT3xx into the
onboard socket.
ꢀ
ꢁ Power up the QTM300CA and, if necessary, the target PCB.
Start QT3View on the PC:
Step 2
Step 3
ꢀ
ꢀ
ꢀ
The PC LED should light up on the QTM300CA.
DEV0 and DEV1 LEDs will indicate the auto-detected chip type (see page 4).
QT3View will select the proper part tab on the screen.
Load / Modify your Setups:
ꢀ
Download the Setups from the chip to your screen using
the ‘Download from Chip’ button (see right) or,
Load in a Setups file from disk
ꢀ
(this will overwrite all three configuration tabs).
Modify the Setups parameters as desired.
ꢀ
ꢀ
ꢀ
ꢀ
Enter the correct target operating supply voltage (see page 6) if necessary.
Enter the total burst length (see page 6) if necessary.
Save the Setups to disk if desired (saves all three tabs into one file).
Clone the Setups to the chip:
ꢀ
Step 4
Upload Setups to the chip from the current tab
using the ‘Upload to Chip’ button (see right).
ꢀ
QT3View will display the success or failure of the clone process in the
“Data Transfer Status Display” at the left of the screen (the PROG LED does not
work in this mode).
ꢀ
ꢀ
Remove the chip and install another and repeat this Step 4,
-or-
Remove the clone cable and connect to another target PCB and repeat this Step 4.
Refer to the device data sheet and the QT3View help file for more information on Setup issues.
lq
7
QTM300CA/R1.02 25.09.03
Download from Www.Somanuals.com. All Manuals Search And Download.
Storing Setups into the QTM300CA
You can save Setup information from the PC to the onboard eeprom of the QTM300CA for use in cloning of
parts on a stand-alone basis. You can also read back these Setups to your PC at any time to verify them. The
QTM300CA can independently store three Setup configurations, one for each part type. Here’s how.....
Hook everything up:
ꢀ
Step 1
Connect the serial cable from the PC to the QTM300CA.
ꢁ Power up the QTM300CA.
ꢁ A target chip or board can be connected but in this process it will not be affected.
Start QT3View on the PC:
ꢀ
Step 2
Step 3
The PC LED should light up on the QTM300CA.
DEV0 and DEV1 LEDs will flash to indicate ‘no part found’ if no part is connected.
ꢀ
Load / Modify the Setups:
ꢀ
ꢀ
ꢀ
Select the device tab in QT3View that you wish to work on.
Load in a Setup file from disk if desired, or,
Load in the Setups stored in the QTM300CA using the ‘Download from
Adapter' button into the current tab. Note, the other tabs will not be affected.
Enter the target operating voltage and burst length (see page 6) if desired.
Change the Setups in the current part tab using the dialog boxes, if desired.
Select a different device tab if you wish to work on another part type, and repeat this
Step 3.
ꢀ
ꢀ
ꢀ
Transfer the data to the QTM300CA’s internal eeprom:
Step 4
ꢀ
Select the device tab which you want to upload to the QTM300CA.
Upload the Setup contents from this tab to the QTM300CA using the
‘Upload to Adapter' button.
ꢀ
ꢀ
ꢀ
QT3View will display the success or failure of the copy process in the “Data Trans-
fer Status Display” at the left of the screen.
Repeat Step 4 with other tabs if desired to copy over other part type Setups.
Cloning Setups from the QTM300CA to a Chip
You can clone Setup information from the QTM300CA to a chip either on a target PCB or inserted into the
onboard socket, without the need for a PC. The QTM300CA stores the Setup information in its onboard
eeprom for use in cloning. The three part types, QT300, QT310, and QT320 each have their own ‘page’ of
Setups in the QTM300CA. Here’s how.....
Hook everything up:
ꢀ
Step 1
Connect the QTM300CA’s cloning cable to the target PCB, or insert a QT3xx chip
into the onboard socket.
ꢀ
ꢀ
Power up the QTM300CA and, if necessary, the target PCB.
The DEV LEDs should indicate the correct part (auto-detected); see page 4.
Clone the Setups to the Chip:
Step 2
ꢀ
ꢀ
ꢀ
Push the PROG button on the board.
The PROG LED will light to indicate programming status.
The PROG LED will flash to indicate the programming result; see page 4.
lq
8
QTM300CA/R1.02 25.09.03
Download from Www.Somanuals.com. All Manuals Search And Download.
Clone Connector Design Rules
Care must be taken when designing an onboard cloning connector. The following are a few requirements
needed for a successful cloning connector design.
Place the connector as close as possible to the chip. Placing the cloning connector far
from the part will increase sensor load capacitance Cx and decrease sensitivity, as
some of the cloning lines are also sense lines. Long distances on cloning lines can
also make the clone process more susceptible to communication errors from ringing
and interference, and create an RF antenna for external fields.
QT320/QT310
If the Synchronization input is used, a 10K resistor should be used to avoid problems
with the cloning process; see Figure 4 below.
QT310
Figure 3 - QT300 Clone Connections
Vdd Vdd
Vdd
Vcc
8
1
2
6
7
DRDY
SCK
DRDY
3
5
Electrode
SCK
REQ
SNS1
SNS2
C
s
REQ
SDO
SDO
4
Vss
Figure 4 - QT310 Clone Connections
Vdd
8
VDD
1
2
6
7
/CAL
/CAL
OUT
OUT
3
5
Electrode
/SYNC_O
/SYNC_O SNS1
/SYNC_I SNS2
10K
C
s
/SYNC_I
VSS
4
lq
9
QTM300CA/R1.02 25.09.03
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 5 - QT320 Clone Connections
Vdd
8
VDD
3
5
S1A
S1B
Electrode 1
C
1
S1
OUT1
OUT2
OUT1
7
6
2
OUT2
S2A
S2B
Electrode 2
C
S2
VSS
4
lq
10
QTM300CA/R1.02 25.09.03
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 1 - Clone Cable Functional Pinout - Usage by Part
Pin
QT300
QT310
QT320
Vcc1
GND
DRDY
N/C
Vcc1
GND
N/C
Vcc1
GND
N/C
1
2
3
4
N/C
N/C
5
N/C
N/C
N/C
6
SDO
SDO
SDI
Vcc1
SCK
N/C
SDO
SDI
Vcc1
SCK
N/C
7
SDI / REQ
Vcc1
8
9
SCK
N/C
10
Note 1: Vcc is connected via a 1K pullup on QTM300CA board
Table 2- Chip ZIF Socket Order Information
ZIF DIP Socket
3M1602-ND
ZIF SMT Socket
309-1048-ND
-
Web sites
Digi-key
Farnell
Logical Systems
103-907
-
PA8SO1-2006-6
Figure 4 - QTM300CA Circuit Diagram
lq
11
QTM300CA/R1.02 25.09.03
Download from Www.Somanuals.com. All Manuals Search And Download.
lQ
Copyright © 2003 QRG Ltd. All rights reserved.
Patented and patents pending
Corporate Headquarters
1 Mitchell Point
Ensign Way, Hamble SO31 4RF
Great Britain
Tel: +44 (0)23 8056 5600 Fax: +44 (0)23 8045 3939
North America
651 Holiday Drive Bldg. 5 / 300
Pittsburgh, PA 15220 USA
Tel: 412-391-7367 Fax: 412-291-1015
The specifications set out in this document are subject to change without notice. All products sold and services supplied by QRG are
every order acknowledgement. QProx, QTouch, QMatrix, QLevel, and QSlide are trademarks of QRG. QRG products are not suitable for
medical (including lifesaving equipment), safety or mission critical applications or other similar purposes. Except as expressly set out in
QRG's Terms and Conditions, no licenses to patents or other intellectual property of QRG (express or implied) are granted by QRG in
connection with the sale of QRG products or provision of QRG services. QRG will not be liable for customer product design and
customers are entirely responsible for their products and applications which incorporate QRG's products.
Download from Www.Somanuals.com. All Manuals Search And Download.
|