S
of device settings.
of basic settings.
of advanced settings.
Changed Bootcode Settings Menu to new
BIOS/UEFI (or FCode) Settings Menu.
Removed Unbind Target option from Target
Level Info & Operations menu.
option.
Added new Target Discovery Menu and its
options.
Removed subheadings referencing non-existent
interactive mode commands.
Added new miscellaneous command line options.
Added new discovered target command line
options.
Added new link configuration command line
options.
Added other new target command line options.
Added unbind persistent target command line
options.
Added new send target and statistics command
line options.
Added new port and HBA configuration parame-
ters (each in a separate table).
Added missing descriptions for parameters.
Deleted obsolete parameters.
SN0054621-00 E
Page iii
Download from Www.Somanuals.com. All Manuals Search And Download.
SANsurfer iSCSI HBA CLI User’s Guide
Command Line Interface for QLogic iSCSI Host Bus Adapters
S
Added missing descriptions for IPv4TOS and
IPv4TTL parameters.
Deleted obsolete Primary_DNS and SLP_Address
parameters.
Moved trace information from 5 Non-Interactive
Mode Commands to a new appendix.
Page iv
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
Table of Contents
Technical Support. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SN0054621-00 E
Page v
Download from Www.Somanuals.com. All Manuals Search And Download.
SANsurfer iSCSI HBA CLI User’s Guide
Command Line Interface for QLogic iSCSI Host Bus Adapters
S
Import HBA Menu, Multiple Adapters (CLI Options -import and
-save) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-9
Select HBA Port. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-11
Update BIOS/UEFI [or FCode] Code Image (CLI Option
-bootcode) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-13
Retrieve FW Flash & NVRAM Record (CLI Option
-dumpnvram) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-15
Port Level Info & Operations Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-19
Page vi
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
SANsurfer iSCSI HBA CLI User’s Guide
Command Line Interface for QLogic iSCSI Host Bus Adapters
A
Display BIOS/UEFI [or FCode] Information (CLI Option
-binfo) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-35
Set BIOS/UEFI [or FCode] Mode (CLI Option
-bootcodemode) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-35
Set Primary Boot Target Information (CLI Option
-pbootcode) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-35
Set Secondary Boot Target Information (CLI Option
-sbootcode) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-35
Clear Primary Boot Target Information (CLI Option
-cpbootcode) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-36
Clear Secondary Boot Target Information (CLI Option
-csbootcode). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-36
SN0054621-00 E
Page vii
Download from Www.Somanuals.com. All Manuals Search And Download.
SANsurfer iSCSI HBA CLI User’s Guide
Command Line Interface for QLogic iSCSI Host Bus Adapters
S
Help (CLI Option -h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-49
Select HBA Port (No CLI Option) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-49
Refresh (No CLI Option). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-49
Exit (No CLI Option) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-50
-df . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-7
Page viii
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
SANsurfer iSCSI HBA CLI User’s Guide
Command Line Interface for QLogic iSCSI Host Bus Adapters
A
5-8
-dv . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-11
-ei) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-12
-h (Help). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-13
-isns6 (iSNS Settings) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-17
-l (List LUN Information) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-17
-lp. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-19
-model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-19
-pa (Add a Target) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-23
-pad . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-24
SN0054621-00 E
Page ix
Download from Www.Somanuals.com. All Manuals Search And Download.
SANsurfer iSCSI HBA CLI User’s Guide
Command Line Interface for QLogic iSCSI Host Bus Adapters
S
-pb (Bind Target) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-24
-pdt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-24
-pet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-24
-pinfo (Port Information). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-24
-ping (Ping Target). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-25
-ps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-25
-pu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-25
-px . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-26
-rdf . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-26
-sdmrc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-29
-sreset (Reset Statistics) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-29
-stadd. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-29
-stat (Display Port Statistics) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-30
-stathba . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-30
-stdsp. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-30
-strd . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-30
-strem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-30
-strema . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-30
-tp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-31
-ts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-31
-z . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-32
HBA-level Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-10
Page x
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
SANsurfer iSCSI HBA CLI User’s Guide
Command Line Interface for QLogic iSCSI Host Bus Adapters
A
Trace Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SN0054621-00 E
Page xi
Download from Www.Somanuals.com. All Manuals Search And Download.
SANsurfer iSCSI HBA CLI User’s Guide
Command Line Interface for QLogic iSCSI Host Bus Adapters
S
List of Figures
Figure
Page
Install Wizard: Select Which Users . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Install Wizard: Destination Folder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Install Wizard: Ready to Install. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Install Wizard: Complete . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
HBA Port Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-14
List of Tables
Table
Page
Supported HBAs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CHAP Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-12
HBA Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-19
HBA Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-10
Target Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Interactive-Mode Error Code Descriptions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
File Names. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Trace Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Trace Level Commands. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Page xii
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
1 Introduction
The command line interface (CLI) application is a simplified, condensed version of
the SANsurfer iSCSI HBA Manager graphical user interface (GUI). SANsurfer
iSCSI HBA CLI does not provide any features that require a GUI.
This introductory chapter covers the following:
Intended Audience
This guide is intended for end users responsible for administration of QLogic
iSCSI HBAs.
How This Guide is Organized
The SANsurfer iSCSI HBA CLI User’s Guide is organized into the following
chapters and appendices:
1 Introduction provides a general overview of the product, lists the supported
QLogic HBAs and operating systems, and provides contact information for
technical support.
2 Installation and Removal provides step-by-step instructions for installing
and uninstalling SANsurfer iSCSI HBA CLI on Windows, Linux, and Solaris.
3 Getting Started describes the two modes used in SANsurfer iSCSI HBA
CLI: interactive and non-interactive.
4 Interactive Mode Commands provides detailed explanations and
examples of the command line options used in the menu-driven interactive
mode.
5 Non-Interactive Mode Commands provides detailed explanations and
examples of the command line options used in non-interactive mode.
SN0054621-00 E
1-1
Download from Www.Somanuals.com. All Manuals Search And Download.
1 – Introduction
How This Guide is Organized
S
Appendix A Port- and HBA-level Parameters provides an alphabetic list of
the HBA port firmware parameters and their values.
Appendix B HBA Statistics provides an alphabetic list of the HBA statistics
shown when you select either the interactive mode Display HBA Statistics
option or the non-interactive mode -statcommand.
parameters, both fixed and configurable.
Appendix D Error Codes provides an alphabetic list of the error codes that
can occur while running SANsurfer iSCSI HBA CLI in both interactive mode
and non-interactive mode.
Appendix E Downloadable File Names lists, by file type and HBA, the typical
file names of downloadable files for QLogic iSCSI HBAs.
Appendix F Using Trace provides information for using trace to identify
application, HBA, and networking issues.
Following the appendices are a glossary of terms used and an index that will help
you quickly find the information you need.
Typographic Conventions
This guide uses the following typographic conventions:
Text in bold font indicates a menu or menu item. For example:
From the HBA Import Menu, type the number for the Import option,
and then press ENTER.
Text in a sans serif font (Courier New) indicates CLI window text output.
For example:
Enter an IP Address:
Text in a bold sans serif font (Courier New) indicates user input (what you
type). For example:
Type y for the Stop on error[Y]? option.
Text in ALL CAPITALS and sans serif font indicates the name of a key that
you press on the keyboard. For example:
Type the number for Host Information and then press ENTER.
Italicized text indicates either a document reference, glossary term, or
emphasis. For example:
The HBA port alias is a symbolic name you assign.
For a complete list, see the QLogic SAN Interoperability Guide.
1-2
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
1 – Introduction
How This Guide is Organized
A
Italicized text within angle brackets indicates user-defined variables. For
example:
-arp <hba_port_inst>
Text within square brackets indicates optional parameters. For example
iscli [optional parameters] [Command Variable]
Text shown in blue indicates a cross-reference hyperlink to a Web site or to
another section of this guide. Click the hyperlink to jump to that site or
section. For example:
firmware and product updates.
Related Documents
SANsurfer iSCSI HBA CLI.
Table 1-1. Related Documents
Part Number
or Name
Title
IS0054501-00
Rev C
Quick Start Guide: iSCSI HBA Installation (PDF).
readme.txt
SANsurfer notes included with SANsurfer iSCSI HBA CLI.
Release notes
SANsurfer iSCSI HBA CLI Release Notes provide details about
modifications made since the previous version. Separate release
notes are provided for each operating system.
IS0054602-00
Rev. B
SANsurfer iSCSI HBA Manager User’s Guide provides details for
using the graphical user interface tool to manage QLogic iSCSI
HBAs.
SN0054621-00 E
1-3
Download from Www.Somanuals.com. All Manuals Search And Download.
1 – Introduction
Supported QLogic HBAs
S
Supported QLogic HBAs
SANsurfer iSCSI HBA CLI is supported on the following QLogic HBAs:
Table 1-2. Supported HBAs
HBA
Ports
Media
QLA4010
1
1
1
1
2
1
2
2
2
Optical
Copper
Optical
Copper
Copper
Copper
Copper
Copper
Copper
QLA4010C
QLA4050
QLA4050C
QLA4052C
QLE4060C
QLE4062C
QMC4052 (IBM)
QMH4062 (HP)
Supported Operating Systems
SANsurfer iSCSI HBA CLI is supported on the following operating systems:
Windows® 2000 Server SP4+ (IA32, x64)
Windows Server™ 2003, Standard or Enterprise Edition SP1 (IA32, x64)
Windows Server 2003, Standard or Enterprise Edition, SP2 (IA32, x64)
Windows Server 2008, Standard or Enterprise Edition (IA32, x64)
Windows XP Professional, SP2 (IA32, x64)
Windows Vista (IA32, x64) (Business and Enterprise editions)
Windows Preinstallation Environment (PE) 2.0, 2.1, PE 2004, PE 2005
Red Hat® Enterprise Linux® (RHEL) 3.0, 4.0, 5.0 (IA32, x64)
Red Hat® Enterprise Linux® (RHEL) 4.0, 5.0 (PPC)
Novell® SUSE® Linux Enterprise Server (SLES) 8.0, 9.0, 10.0 (IA32, x64,
PPC)
Solaris® SPARC 9, 10
Solaris x86 9, 10 (IA32, x64)
NOTE:
Throughout this guide, HBA may be shortened to adapter. The term device
often refers to targets.
1-4
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
1 – Introduction
License Agreements
A
License Agreements
Refer to the QLogic Software End User License Agreement for a complete listing
of all license agreements affecting this product.
Technical Support
Customers should contact their authorized maintenance provider for technical
support of their QLogic switch products. QLogic-direct customers may contact
QLogic Technical Support; others will be redirected to their authorized
maintenance provider.
For the latest firmware and software updates, visit the QLogic support Web site
Availability
QLogic Technical Support for products under warranty is available during local
standard working hours, excluding QLogic Observed Holidays.
Training
QLogic offers certification training for the technical professional for both the
may choose Electronic-based Training or schedule an intensive “hands-on”
Certification course.
troubleshooting QLogic SAN products. Upon demonstrating knowledge using live
Professional. The training professionals at QLogic may be reached by e-mail at
Contact Information
Please feel free to contact your QLogic approved reseller or QLogic Technical
Support at any phase of integration for assistance. QLogic Technical Support can
be reached by the following methods:
Web
North America Contact Information
E-mail
Phone
(952) 932-4040
Support contact information for other regions of the world is available at the
QLogic Web site: http://support.qlogic.com
SN0054621-00 E
1-5
Download from Www.Somanuals.com. All Manuals Search And Download.
1 – Introduction
Technical Support
S
The QLogic knowledge database contains troubleshooting information for the
Click the Support tab, and then use the search engine at the top of the page to
look for specific troubleshooting information.
1-6
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
2 Installation and Removal
This section provides procedures for the following:
Before you can run SANsurfer iSCSI HBA CLI, ensure that your system meets the
following requirements:
HBAs are installed.
HBA drivers are installed.
To install SANsurfer iSCSI HBA CLI, the PC hard disk must have about 1
MB free space.
NOTE:
SANsurfer iSCSI HBA CLI is designed to configure QLogic HBAs on the
local machine (where it is installed). It cannot configure HBAs on remote
machines.
Installing SANsurfer iSCSI HBA CLI
This section on SANsurfer iSCSI HBA CLI installation includes the following
information:
Downloading the Installation Package
Follow the procedure in this section to download the SANsurfer iSCSI HBA CLI
installation package from the QLogic Web site.
To download the installation package:
1.
2.
Select your HBA.
SN0054621-00 E
2-1
Download from Www.Somanuals.com. All Manuals Search And Download.
2 – Installation and Removal
Installing SANsurfer iSCSI HBA CLI
S
3.
4.
Under Drivers, Management Tools, and API Libraries: click the
appropriate operating system.
In the SANsurfer iSCSI row of the Management Tools table, in the
Download column, click Download.
SANsurfer iSCSI HBA CLI shows the End User License Agreement box.
Scroll to the bottom, and then click Agree.
5.
6.
SANsurfer iSCSI HBA CLI shows the File Download dialog box.
Click Save. Select a directory on your system and download the file.
The installation package has the following naming convention:
iscli-AA.BB.CC-DD_<OS Type>_<Subtype>.<Install Type>
Where:
AA.BB.CC-DD = Version number
OS Type = One of the following:
win
linux
solaris
Subtype = One of the following:
i386
PPC 64 (Power PC)
sparc_x86
(There is no Subtype in the Windows package name.)
Install Type = One of the following:
rpm (Linux)
exe (Windows)
Z (Solaris)
For example, a package for the Linux operating system can be named:
iscli-1.0.35-0_linux_i386.rpm
7.
Follow the installation instructions in the section for your operating system
(OS):
Windows2000 Server SP4+ (IA32, x64)
Windows Server 2003, Standard or Enterprise Edition SP1 (IA32,
x64)
2-2
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
2 – Installation and Removal
Installing SANsurfer iSCSI HBA CLI
A
Windows Server 2003, Standard or Enterprise Edition, SP2
(IA32, x64)
Windows XP Professional (IA32, x64) SP2
Windows Vista (IA32, x64) (Business and Enterprise editions)
Windows Preinstalled Environment (PE) 2.0, PE 2004, PE 2005
Red Hat/SUSE Linux/Power PC (PPC) (see “Installing on Red
Solaris SPARC/Solaris x86 (see “Installing on Solaris SPARC/Solaris
SN0054621-00 E
2-3
Download from Www.Somanuals.com. All Manuals Search And Download.
2 – Installation and Removal
Installing SANsurfer iSCSI HBA CLI
S
Installing on Microsoft Windows
Choose one of the following options for installing SANsurfer iSCSI HBA CLI:
Windows Standard (GUI) Installation
Follow these steps to install SANsurfer iSCSI HBA CLI on a Windows operating
system.
To install using the GUI installation:
1.
Locate and double-click the install package on the CD or Web site.
Figure 2-1 Install Wizard: Welcome
2.
Read the information, and then click Next.
2-4
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
2 – Installation and Removal
Installing SANsurfer iSCSI HBA CLI
A
Figure 2-2 Install Wizard: Select Which Users
3.
Choose whether you want SANsurfer iSCSI HBA CLI available for all users
or only the current user, and then click Next.
Figure 2-3 Install Wizard: Destination Folder
SN0054621-00 E
2-5
Download from Www.Somanuals.com. All Manuals Search And Download.
2 – Installation and Removal
Installing SANsurfer iSCSI HBA CLI
S
4.
Choose one of the following options:
To select the destination in the dialog box, click Next (recommended).
The default location for a Microsoft Windows system is:
Program Files\QLogic Corporation\SANsurferiCLI
To select a different location, click Change, select the location you
want, and then click Next.
Figure 2-4 Install Wizard: Ready to Install
5.
To begin installation, click Install.
2-6
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
2 – Installation and Removal
Installing SANsurfer iSCSI HBA CLI
A
Windows Command Line Installation
You can install SANsurfer iSCSI HBA CLI from the command prompt using the
Microsoft Windows Installer (MSI). Use one of the following methods:
NOTE:
You can also configure the installation using MSI commands. To see a
summary of MSI commands, at the command prompt, type: msiexec.
To obtain more information about MSI, visit the Microsoft Web site.
Standard Windows Interactive (CLI) Installation
To begin a standard installation of SANsurfer iSCSI HBA CLI on a Microsoft
Windows operating system, at a command line, type one of the following:
SANsurferCLI.msi
msiexec /i SANsurferCLI.msi
The default directory for SANsurfer iSCSI HBA CLI application is:
Program files\QLogic Corporation\SANsurferCLI
If you want a different directory, type it in the command line. For example:
SANsurferCLI.msi INSTALLDIR="directory"
The preceding command installs SANsurfer iSCSI HBA CLI in the directory
named directory. Use full path names.
Quiet or Unattended Windows Installation
Type the following for a quiet (silent) installation using default values. For
example, the following command installs silently using defaults and does not show
any errors:
SANsurferCLI.msi /q
Passive Windows Installation
Type the following for a passive installation using default values. For example:
SANsurferCLI.msi /passive
Installs with minimum interaction, showing only the progress bar and any errors.
SN0054621-00 E
2-9
Download from Www.Somanuals.com. All Manuals Search And Download.
2 – Installation and Removal
Installing SANsurfer iSCSI HBA CLI
S
Overwrite Previous Windows Installations
Type the following for an installation that overwrites any previous installations
without asking for confirmation. Type:
SANsurferX-AgentOnly.msi /i FORCEINSTALL=TRUE
Installing on Red Hat/SUSE Linux/PPC
SANsurfer iSCSI HBA CLI installation on a Linux system requires that you use the
“quiet” installation method. This method ensures that, if needed, the Linux driver
interface module (ioctl module) is also installed.
To install quietly on Linux:
1.
Unzip and untar the iSCSI CLI gzipped tar bundle as follows:
tar -xvzf
2.
To start the installation, type:
./iscli.dkms.install.sh install
Installing on Solaris SPARC/Solaris x86
You can install SANsurfer iSCSI HBA CLI on a Solaris SPARC or x86 system with
one of the following methods:
Solaris Attended Installation
Follow this procedure from the command prompt to install SANsurfer iSCSI HBA
CLI on a Solaris SPARC/Solaris x86 operating system.
To install attended on Solaris:
1.
Installation Package” on page 2-1, type the following:
uncompress iscli-AA.BB.CC-DD_solaris_sparc_x86.Z
2.
To install iSANsurfer iSCSI HBA CLI on a Solaris SPARC/Solaris x86
operating system, type the following:
pkgadd -d iscli-AA.BB.CC-DD_solaris_sparc_x86
Solaris puts the files in the following directory:
/opt/QLogic_Corporation/SANsurferiCLI
It also adds this directory to the execution path.
2-10
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
2 – Installation and Removal
Installing SANsurfer iSCSI HBA CLI
A
Solaris Silent Installation
This section contains a pkgadd (SOLARIS) example for silent installation.
To install silently on Solaris:
1.
Create the following two files:
response.txt
noask_pkgadd.txt
2.
3.
Run the pkgaddcommand.
Create the response.txtfile with contents of first question of arch, for
example:
<BOF> 1 <EOF>
4.
5.
Create the noask_pkgadd.txtfile with contents:
<BOF> action=nocheck <EOF>
Type the command to Install with the two additional (required) files:
pkgadd -d ./<Install Package Filename> -n -a
./noask_pkgadd.txt < ./response.txt
For example:
pkgadd -d ./iscli-1.1.00-11_solaris_sparc_x86 -n -a
./noask_pkgadd.txt < ./response.txt
Available packages include:
QLSisclisparc—QLogic SANsurfer iSCSI CLI (HBA Configuration
Utility) (SPARC) 1.1.00 Build 11 (Solaris 8-11)
QLSisclix86—QLogic SANsurfer iSCSI CLI (HBA Configuration
Utility) (x86) 1.1.00 Build 11 (Solaris 9-11)
6.
Select the package(s) you want to process (or allto process all packages).
(default: all) [x,xx,q]:
SN0054621-00 E
2-11
Download from Www.Somanuals.com. All Manuals Search And Download.
2 – Installation and Removal
Removing SANsurfer iSCSI HBA CLI
S
Removing SANsurfer iSCSI HBA CLI
To remove SANsurfer iSCSI HBA CLI from your system, follow the instructions that
that correspond to your OS:
Microsoft Windows Uninstall
The Windows OS offers the following methods of uninstalling SANsurfer iSCSI HBA
CLI:
Start Menu Uninstall
On the Windows Start menu, point to All Programs > QLogic Management
Suite > SANsurferiCLI, and then click Uninstall SANsurferiCLI.
Control Panel Uninstall
Follow these steps to uninstall SANsurfer iSCSI HBA CLI using the Windows
Control Panel.
To uninstall from the Control Panel:
1.
2.
3.
4.
On the Start menu, click Control Panel.
Click Add/Remove Programs.
Select SANsurferiCLI.
Click Change/Remove.
Command Line Uninstall
You can uninstall SANsurfer iSCSI HBA CLI from the command line. Select
interactive, passive, or silent uninstall.
To uninstall interactively from the command line:
Enter the following from a command prompt:
SANsurferiCLI.msi
To uninstall passively from the command line:
Enter the following from a command prompt:
msiexec /x SANsurferiCLI.msi
2-12
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
2 – Installation and Removal
Removing SANsurfer iSCSI HBA CLI
A
To uninstall quietly from the command line:
Enter the following from a command prompt:
msiexec /q /x SANsurferiCLI.msi
Red Hat/SUSE Linux/PPC Uninstall
To uninstall SANsurfer iSCSI HBA CLI on a Red Hat/SUSE Linux/PPC operating
system, enter the following from a command prompt:
rpm -e iscli-AA.BB.CC-DD(be sure to omit the rest of the package name)
Solaris SPARC/Solaris x86 Uninstall
To uninstall SANsurfer iSCSI HBA CLI on a Solaris SPARC/Solaris x86 operating
system, enter one of the following commands:
pkgrm QLisclix86(Solaris x86)
pkgrm QLisclisparc(Solaris SPARC)
SN0054621-00 E
2-13
Download from Www.Somanuals.com. All Manuals Search And Download.
2 – Installation and Removal
Removing SANsurfer iSCSI HBA CLI
S
Notes
2-14
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
3 Getting Started
Introduction
SANsurfer iSCSI HBA CLI operates in the two following modes:
Interactive mode. SANsurfer iSCSI HBA CLI starts and prompts for user
input. Based on the input, the CLI executes the specified commands until
terminated by the user. Use this mode to perform multiple operations.
4 Interactive Mode Commands covers this interface.
Non-interactive (command line) mode. SANsurfer iSCSI HBA CLI starts,
performs the functions defined by the list of parameters provided, and then
terminates. Use this mode to run SANsurfer iSCSI HBA CLI from a script file
or when you want to perform a single operation. 5 Non-interactive Mode
Commands covers this interface.
In both modes, SANsurfer iSCSI HBA CLI is case sensitive. In addition, file names
in some operating systems are case sensitive; in this case, SANsurfer iSCSI HBA
CLI is case sensitive for that particular file.
Starting Interactive Mode
To start SANsurfer iSCSI HBA CLI in interactive mode, choose one of the
following options:
Type the following in a command window:
iscli
Figure 3-1 Windows iSCSI icon
SN0054621-00 E
3-1
Download from Www.Somanuals.com. All Manuals Search And Download.
3 – Getting Started
Starting Non-interactive Mode
S
The Windows system displays the Main Menu. For example:
main Interactive Menu
-------------------------------------------------------
Program Version: 1.2.00.xx Driver Version: 2.1.x.x (STOR w32) IC: 1
Current HBA/Port Information: HBA Alias: qlogic
HBA: 0 Port: 0 HBA Port Index: 1 Model: QLA4050C
IP Address: 192.168.104.129
Link: Up
Port iSCSI Name: iqn.2000-04.com.qlogic:qla4050C.fs10506a02810.1
Port iSCSI Alias:
-------------------------------------------------------
1. Display Program Version Information
2. Host Level Info & Operations
3. HBA Level Info & Operations
4. Port Level Info & Operations
5. List All QLogic iSCSI HBA Ports detected
6. Help
7. Select HBA Port
8. Refresh
9. Exit
enter selection:
Depending on the menu selection, SANsurfer iSCSI HBA CLI prompts for more
input as needed. For example, if you select Select HBA Port, SANsurfer iSCSI
HBA CLI lists the current HBAs and prompts you to select an HBA whose settings
you want to view or change.
Starting Non-interactive Mode
Type the following in a command window to start SANsurfer iSCSI HBA CLI in
non-interactive mode:
iscli <Parameters>
SANsurfer iSCSI HBA CLI executes the command options, and then terminates.
To list all of the available command line parameters, type the following:
iscli -h
All command line options must be preceded by the dash (–) notation. Most options
have a corresponding menu selection in interactive mode.
3-2
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
4 Interactive Mode
Commands
This chapter provides an explanation of each menu and menu option in the
SANsurfer iSCSI interactive command line interface (CLI).
The command line interface commands are nested and some selections from the
main menu open new menus. For example, if you click item 2. Host Level Info &
Operations on the main menu, SANsurfer iSCSI HBA CLI displays a new menu,
the Host Level Info & Operations Menu. From this menu you have several
choices, including 1. Display General System Information, 2. Import HBA
Menu, Multiple Adapters, and so forth.
On every menu, to move to the next higher level (parent) menu, type the number
for Exit.
navigate the menu hierarchy. The numbers in the left column (Level 1) represent
the items on the main interactive menu.
SN0054621-00 E
4-1
Download from Www.Somanuals.com. All Manuals Search And Download.
4 – Interactive Mode Commands
A
Table 4-1. Command Line Interface Menu (Continued)
Level 2 Level 3 Level 4
Level 1
SN0054621-00 E
4-3
Download from Www.Somanuals.com. All Manuals Search And Download.
4 – Interactive Mode Commands
S
Table 4-1. Command Line Interface Menu (Continued)
Level 2 Level 3 Level 4
Level 1
4-4
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
4 – Interactive Mode Commands
A
Table 4-1. Command Line Interface Menu (Continued)
Level 2 Level 3 Level 4
Level 1
SN0054621-00 E
4-5
Download from Www.Somanuals.com. All Manuals Search And Download.
4 – Interactive Mode Commands
S
Table 4-1. Command Line Interface Menu (Continued)
Level 2 Level 3 Level 4
Level 1
4-6
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
4 – Interactive Mode Commands
A
Table 4-1. Command Line Interface Menu (Continued)
Level 2 Level 3 Level 4
Level 1
SN0054621-00 E
4-7
Download from Www.Somanuals.com. All Manuals Search And Download.
4 – Interactive Mode Commands
Display Program Version Information (CLI Option -ver)
S
Display Program Version Information
(CLI Option -ver)
When you select this option, SANsurfer iSCSI HBA CLI displays the following
information:
SANsurfer iSCSI HBA CLI
Program version : x.x.xx.xx
iSDMAPI (iSCSI SAN device manager API) xx.xx.xx.xx QLSDM.DLL 06
IOCTL
Copyright 1999-2008 QLogic Corp.
Host Level Info & Operations Menu
Before making a selection from the Host Level Info & Operations Menu, you
must select an HBA.
To choose an HBA:
1.
2.
3.
Type the number for the Select HBA Port option, and then press ENTER.
A list of HBA port instances appears.
Type the number for the HBA port instance you want to change, and then
press ENTER.
4.
Make changes in the following submenus:
5.
6.
For each submenu, save the changes by typing the number for Save
changes and reset HBA, and then pressing ENTER. This saves your
changes and resets all ports on the HBA.
To update the firmware with these changes, type the number for Refresh,
and then press ENTER. If you do not select this option, your changes will not
be visible in SANsurfer iSCSI HBA CLI.
4-8
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
4 – Interactive Mode Commands
Host Level Info & Operations Menu
A
Display General System Information
(CLI Option -g)
Choose the Display General System Information option to show information
about SANsurfer iSCSI HBA CLI; for example:
Host Name : (name)
Host Version: Service Pack n (Build xxxx)
Host Type : Microsoft Windows Server 2003 Enterprise Edition x64
User Type : Privileged; HBA setup allowed
Import HBA Menu, Multiple Adapters
(CLI Options -import and -save)
From the Import HBA Menu, choose one of the following options:
Before making a selection from the Import HBA Menu, specify the HBA port
whose settings you want to view or change by typing the number for Select HBA
Port, and then press ENTER. A list of all iSCSI HBA ports is displayed. Type the
number for the HBA port whose settings you want to change, and then press
ENTER.
Make changes in the submenus, as described in the following sections.
Save Host Configuration
(CLI Option -save)
To save the current host configuration to an XML file:
1.
2.
From the HBA Import Menu, type the number for the Save option, and then
press ENTER.
SANsurfer iSCSI HBA CLI prompts you to enter a file name to save the host.
Type a file name or a path to a file. If you do not specify a path, the file is
saved in the current directory:
Program Files\QLogic Corporation\SANsurfer
SN0054621-00 E
4-9
Download from Www.Somanuals.com. All Manuals Search And Download.
4 – Interactive Mode Commands
Host Level Info & Operations Menu
S
Import HBA Configuration
(CLI Option -import)
To import a single HBA configuration:
1.
2.
3.
From the HBA Import Menu, type the number for the Import option, and
then press ENTER.
SANsurfer iSCSI HBA CLI prompts you to enter a file name containing the
HBA configuration.
Type the path and file name of the saved HBA configuration you want to
import, and then press ENTER.
SANsurfer iSCSI HBA CLI reads the file, shows the HBAs whose
configurations are in the file, and prompts you to select one to import.
Type the number of the HBA whose configuration you want to import, and
then press ENTER.
The following appears:
You will now specify the target HBA to import the
configuration to.
Please select a method for identifying the destination
port(s):
1) Import to ALL ports.
2) Import to a list of ports (comma delimited).
3) Import to the currently selected port.
Please select an option:
4.
5.
Select a configuration import option, and then press ENTER.
You are now ready to choose which parameter sets to import.
Please respond yes (y) or no (n) to each parameter set.
Select from the following parameter sets to import:
HBA Level Settings
Network Settings
iSCSI Name
Firmware Settings
CHAP Table
Target Settings (required if you Boot Settings is needed)
Boot Settings
4-10
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
4 – Interactive Mode Commands
Host Level Info & Operations Menu
A
NOTE:
Because the default is n(no), if you press ENTERafter the prompt
without typing yor n, you have essentially declined to import that
setting.
After you have selected the parameter sets to import, the following message
is displayed:
Resetting HBA This may take a few minutes.
After the HBA is reset, the HBA Import Menu reappears.
Update Firmware, Multiple Adapters
When you select the Update Firmware, Multiple Adapters option, SANsurfer
iSCSI HBA CLI prompts you to enter the file name of the new firmware. Be sure to
use full path names when specifying the new firmware file.
When finished typing the firmware file name and path, press ENTER.
Install HBA Driver, All Adapters
(CLI Option -d)
When you select the Install HBA Driver, All Adapters option, SANsurfer iSCSI
HBA CLI shows the current driver version and prompts you to enter the name of a
new driver. Be sure to use full path names when entering a new driver name.
Current driver version n.n.n.n for HBA Port: 0
Enter a driver file name or press <Enter> to return to Main Menu
Driver file:
When finished typing the driver name and path, press ENTER.
Select HBA Port
For information regarding this option, see “Select HBA Port (No CLI Option)” on
SN0054621-00 E
4-11
Download from Www.Somanuals.com. All Manuals Search And Download.
4 – Interactive Mode Commands
HBA Level Info & Operations Menu (CLI Option -i)
S
HBA Level Info & Operations Menu
(CLI Option -i)
The HBA Level Info & Operations Menu provides the following options for each
HBA port instance:
On each submenu, save the changes by typing the number for Save changes
and reset HBA, and then pressing ENTER. This saves your changes and resets
all ports on the HBA.
To update the firmware with these changes, type the number for Refresh, and
then press ENTER. If you do not select this option, your changes will not be visible
in SANsurfer iSCSI HBA CLI.
HBA Information
(CLI Option -ch)
When you select the HBA Information option, information is listed for the working
adapter; for example:
Board Type
: QLE4060C
: ISP4032
Chip Model
Chip Version
Serial Number
MAC Address
: 0
: QS40620A00034
: 00-C0-DD-08-97-40
: 2.1.4.18 (STOR w32)
: 3.0.1.45
: 1.0.0.0
Driver Version
Firmware Version
ROM Version
iSCSI Version
BIOS/UEFI Version
: 0.20
: 1.00
BIOS/UEFI Full Version : 1.00
4-12
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
4 – Interactive Mode Commands
HBA Level Info & Operations Menu (CLI Option -i)
A
HBA Options Menu
(No CLI Option)
The HBA Options Menu provides the following selections:
On each submenu, save the changes by typing the number for Save changes
and reset HBA, and then pressing ENTER. This saves your changes and resets
all ports on the HBA.
To update the firmware with these changes, type the number for Refresh, and
then press ENTER. If you do not select this option, your changes will not be visible
in SANsurfer iSCSI HBA CLI
Update BIOS/UEFI [or FCode] Code Image
(CLI Option -bootcode)
This menu option varies, depending on your system architecture (automatically
detected by SANsurfer iSCSI HBA CLI). Bootcode (that is, the bootable code
image) is either BIOS, FCode, or EFI that allows system boot from an iSCSI drive.
Select the Update BIOS/UEFI Image or Update FCode Code Image option to
update the bootcode code image, which should be done when QLogic releases a
new bootcode with bug fixes or enhancements. At the prompt, type the name of
the file containing the bootcode code image to upload to the HBA.
For information on bootcode file names, see Appendix E Downloadable File
Update Firmware Image
(CLI Option -f)
The firmware is the code running on the HBA to perform the tasks involved in data
management, the iSCSI protocol, and general HBA functioning.
Select the Update Firmware Image option to update the firmware image. At the
prompt, type the name of the file containing the firmware image to upload to the
HBA.
For information on firmware file names, see Appendix E Downloadable File
SN0054621-00 E
4-13
Download from Www.Somanuals.com. All Manuals Search And Download.
4 – Interactive Mode Commands
HBA Level Info & Operations Menu (CLI Option -i)
S
CAUTION!
Before updating the firmware image, be sure that no I/O processes are
running.
An administrator must take necessary actions to ensure changes will be
fully recognized by the operating system (reboot, flush cache, sync disk,
and so forth.)
A firmware update and reset will be performed that requires all
applications accessing impacted LUNs to be shut down.
Any impacted systems must be unmounted.
Following firmware update, be sure to select Save changes and reset
HBA; otherwise, the change will not take effect.
Update ROM Image
(CLI Option -r)
Select the Update ROM Image option to update the ROM image. At the prompt,
type the name of the file containing the ROM image to upload to the HBA.
For information on ROM Image file names, see Appendix E Downloadable File
CAUTION!
Before updating the ROM image, ensure that no I/O processes are
running.
An administrator must take necessary actions to ensure changes will be
fully recognized by the operating system (reboot, flush cache, sync disk,
and so forth).
A ROM update and reset will be performed that requires all applications
accessing impacted LUNs to be shut down.
Any impacted systems must be unmounted.
To ensure your changes take effect, be sure to select Save changes
and reset HBA.
HBA Reset
(CLI Option -b)
Select the HBA Reset option to reset the HBA after making configuration
changes.
4-14
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
4 – Interactive Mode Commands
HBA Level Info & Operations Menu (CLI Option -i)
A
NOTE:
Issuing this command resets both ports (0 and 1) on the HBA.
[or FCode] Mode)” on page 5-4) to reset the HBA.
HBA Diagnostic Menu
(No CLI Option)
The HBA Diagnostic Menu provides the following options:
Before making a selection from the HBA Diagnostic Menu, specify the HBA port
you want to view or change by typing the number for Select HBA Port, and then
pressing ENTER. A list of all iSCSI HBA ports is shown. Type the number for the
HBA port whose settings you want to change, and then press ENTER.
Make changes in the submenus, as described in the following sections.
After making changes, refresh the HBA to show these changes by typing the
number for (Refresh), and then pressing ENTER. If you do not select this option,
your changes will not be visible in SANsurfer iSCSI HBA CLI.
Retrieve FW Crash Record
(CLI Option -gcr)
Select the Retrieve FW Crash Record option to get crash record information for
the HBA. At the prompt, type a name and location for the crash file, and then
press ENTER. Be sure to use full path names. For example:
Crash File Name: c:\QLogic_Corporation\iscli\crash_record
Retrieve FW Flash & NVRAM Record
(CLI Option -dumpnvram)
When you select the Retrieve FW Flash & NVRAM Record option, SANsurfer
iSCSI HBA CLI queries you for the name of a file in which to dump the Flash and
NVRAM contents. Be sure to use full path names. For example:
What is the filename you would like to save this Host NVRAM to:
c:\QLogic_Corporation\iscli\NVRAM_dump
SN0054621-00 E
4-15
Download from Www.Somanuals.com. All Manuals Search And Download.
4 – Interactive Mode Commands
HBA Level Info & Operations Menu (CLI Option -i)
S
Retrieve FW Coredump Record
(CLI Option -dumpcore)
When you select the Retrieve FW Coredump Record option, SANsurfer iSCSI
HBA CLI queries you for the name of a file in which to dump the Flash and core
contents. Be sure to use full path names. For example:
What is the filename you would like to save this Host CoreDump to:
c:\QLogic_Corporation\iscli\NVRAM_dump
Display HBA Level Statistics
(CLI Option -stathba)
When you select the Display HBA Level Statistics option, SANsurfer iSCSI HBA
CLI lists statistics for the selected HBA. For example:
MACTxFramesCount
MACTxBytesCount
: 118
: 26705
: 4
MACTxMulticast
MACTxBroadcast
: 11
: 0
MACTxPauseFrames
MACTxControlFrames
MACTxDeferrals
: 0
: 0
MACTxExcessDeferrals
MACTxLateCollisions
MACTxAborts
: 0
: 0
: 0
MACTxSingleCollisions
MACTxMultipleCollisions
MACTxCollisions
: 0
: 0
: 0
MACTxFramesDropped
MACTxJumboFrames
MACRxFramesCount
MACRxBytesCount
: 0
: 0
: 673
: 173161
MACRxUnknownControlFrames : 0
MACRxPauseFrames
MACRxControlFrames
MACRxDribble
: 0
: 0
: 0
: 0
: 0
: 0
: 0
: 0
: 0
: 0
MACRxFrameLengthError
MACRxJabber
MACRxCarrierSenseError
MACRxFramesDiscarded
MACRxFramesDropped
MACCRCErrorCount
MACEncodingErrorCount
4-16
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
4 – Interactive Mode Commands
HBA Level Info & Operations Menu (CLI Option -i)
A
MACRxLengthErrorCountLarge : 0
MACRxLengthErrorCountSmall : 0
MACRxMulticast
MACRxBroadcast
: 402
: 177
HBA Level Parameters Menu
(No CLI Option)
To make changes to the HBA level parameters:
1.
Specify the HBA port whose settings you want to view or change by typing
the number for Select HBA Port, and then press ENTER.
SANsurfer iSCSI HBA CLI lists all iSCSI HBA ports.
2.
3.
Type the number for the HBA port whose settings you want to change, and
then press ENTER.
Make changes in the submenus, as described in the following sections:
4.
5.
For each submenu, save the changes by typing the number for the Save
changes and reset HBA option, and then press ENTER. This saves your
changes and resets all ports on the HBA.
To update the firmware with these changes, type the number for Refresh,
and then press ENTER. If you do not select this option, your changes will not
be visible in SANsurfer iSCSI HBA CLI.
NOTE:
The parameters available vary with the type of HBA.
Display HBA Level Parameters
(CLI Option -i)
Select the Display HBA Level Parameters option to view information about the
HBA. For example:
HBA_Alias
: hba3
HBA_TCP_Max_Window_Size
: 32768
HBA_Default_Fragment_Reass_Timeout : 40
SN0054621-00 E
4-17
Download from Www.Somanuals.com. All Manuals Search And Download.
4 – Interactive Mode Commands
HBA Level Info & Operations Menu (CLI Option -i)
S
HBA_Reserved_TCP_Config
HBA_Delayed_ACK
: 0x0001314c
: on
Note that not all parameters are available for all HBA models.
Configure HBA Level Parameters
(CLI Option -n)
Select the Configure HBA Level Parameters option to configure a single port on
any HBA, whether it has only one port or more than one. Be sure to select the
working adapter you want to configure. (For details, see “Select HBA Port (No CLI
When you enter this option, SANsurfer iSCSI HBA CLI queries you for each HBA
parameter in sequence. It shows the current value of that parameter in brackets
[value]. Type a new value for each parameter, and then press ENTER. To leave
a parameter set to the current value, just press ENTER.
Save Changes and Reset HBA
Before resetting the HBA, ensure no connections are active. Select the Save
Changes and Reset HBA option to save your changes and reset all ports on the
HBA.
Display VPD Information
(CLI Option -vpd)
When you select the Display VPD Information option, the vital product data
(VPD) information is displayed for the current working adapter. Information varies
by manufacturer, or may not be provided by the manufacturer at all. For example,
the adapter’s manufacturer may choose to show the following:
Product description
Part number
EC (European community) level
Manufacture ID
FRU (field replaceable unit) number
CCIN (customer card identification number)
Brand Field
4-18
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
4 – Interactive Mode Commands
Port Level Info & Operations Menu
A
Port Level Info & Operations Menu
The Port Level Info & Operations Menu provides the following options:
On each submenu, save the changes by typing the number for the Save changes
and reset HBA option, and then pressing ENTER. This saves your changes and
resets all ports on the HBA.
To update the firmware with these changes, type the number for the Refresh
option, and then press ENTER. If you do not select this option, your changes will
not be visible in SANsurfer iSCSI HBA CLI.
Port Link Settings Menu
Select the Port Link Settings Menu option to open the Port Link Configuration
Menu containing the following options:
Display Active Link Configuration
Select the Display Active Link Configuration option to view the following
information about the active link:
Connection type
Portal Duplex
: (Copperor Fiber)
: (Half-duplex, Full-duplex, or Disabled)
Portal Flow Control : (onor off)
Portal Link speed : (in Mbs)
SN0054621-00 E
4-19
Download from Www.Somanuals.com. All Manuals Search And Download.
4 – Interactive Mode Commands
Port Level Info & Operations Menu
S
Display Configured Link Configuration
(CLI Option -lcd)
Select the Display Configured Link Configuration option to view the following
information about the configured link:
Portal Flow Control
: (onor off)
Auto-negotiate link speed: (onor off)
Link Speed
: (in Mbs)
Configure Link Configuration
(CLI Option -lc)
Select the Configure Link Configuration option to view and modify each of the
configurable link settings, including:
Auto-negotiate link speed
Flow Control
The current setting (onor off) is shown in brackets. To change a setting, type on
or off, and then press ENTER.
Save Changes and Reset HBA (if necessary)
Before resetting the HBA, ensure no connections are active. Select the Save
Changes and Reset HBA option to save your changes and reset all ports on the
HBA.
Port Network Settings Menu
The Port Network Settings Menu options include the following:
Display Network Settings
(CLI Options -netconf)
Select the Display Network Settings option to view the settings for dynamic host
configuration protocol (DHCP), link local address, IPv6, and iSNS. For example:
Using DHCP to obtain an IP Addresses.
IPv4 Address
Gateway
: 10.14.65.19
: 10.14.64.1
Subnet Mask
: 255.255.254.0
4-20
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
4 – Interactive Mode Commands
Port Level Info & Operations Menu
A
Link Local Address
: fe80::2c0:ddff:fe08:5a13
IPv6 Local Address State : Valid (0x5)
IPv6 Address 0
: Source Address Not Valid
: Source Address Not Valid
IPv6 Address 1
IPv6 Default Router
IPv6 Port Number
: Router Address Not Valid
: 3260
IPv6 Router Adv Link MTU : 0 bytes
iSNS : Disabled.
Configure IP Settings
(CLI Option -ipdhcp)
Select the Configure IP Settings menu to enable or disable the following
features:
Enable IPv4
DHCP to obtain IPv4 Network Information
Enable IPv6
Obtain Link Local Auto
Obtain Routable Address Auto
Obtain Router Address Auto
IPv6 Default Router IP Address
You are prompted to turn on or off each feature; the current state is shown at the
end of the prompt. For example, the following prompt indicates that the router
address is not obtained automatically:
Obtain Router Addr Auto [off] :
To change this setting, type on, and then press ENTER(be sure to turn off the
CAPS LOCKkey; entries are case sensitive). If you do not want to change this
setting, press ENTER.
iSNS Settings
(CLI Option -isns)
By default, iSNS is disabled. Use iSNS when extended discovery management
capabilities (for example, notifications, access management, and configuration)
are required, such as in larger storage networks.
To enable iSNS, type onat the Use iSNS: [off]prompt, and then press
ENTER. You are prompted to enter an iSNS IP address.
SN0054621-00 E
4-21
Download from Www.Somanuals.com. All Manuals Search And Download.
4 – Interactive Mode Commands
Port Level Info & Operations Menu
S
Edit Configured Port Settings Menu
To edit the configured HBA settings:
1.
Specify the HBA port whose settings you want to view or change by typing
the number for Select HBA Port, and then pressing ENTER.
SANsurfer iSCSI HBA CLI lists all iSCSI HBA ports.
2.
3.
Type the number for the HBA port whose settings you want to change, and
then press ENTER.
For the selected HBA port, select from the following options:
4.
5.
For each submenu, save the changes by typing the number for the Save
changes and reset HBA option, and then pressing ENTER. This saves your
changes and resets all ports on the HBA.
To update the firmware with these changes, type the number for the Refresh
option, and then press ENTER. If you do not select this option, your changes
will not be visible in SANsurfer iSCSI HBA CLI.
Display Configured Port Settings
(CLI Option -c)
When you select this option, all of the firmware parameters and their values are
displayed for the HBA port. For a description of the firmware settings, refer to
Change Port ISCSI Alias Name
(No CLI Option)
NOTE:
This command is only available in interactive mode.
The HBA port alias is a symbolic name you assign to the HBA for identification. To
assign an alias, type the name at the prompt. The name can have between 0 and
255 characters, and must be terminated with at least one NULL character.
4-22
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
4 – Interactive Mode Commands
Port Level Info & Operations Menu
A
HBA port aliases are communicated between the initiator and target at login, and
can be displayed on the PC monitor on both sides, making it easy to see if the
initiators and targets are correct. Do not use the alias to identify, address, or
authenticate initiators or targets.
Port Firmware Settings Menu
To make changes to the HBA firmware settings:
1.
Specify the HBA port whose settings you want to view or change by typing
the number for Select HBA Port, and then pressing ENTER.
A list of all iSCSI HBA ports is displayed.
2.
3.
Type the number for the HBA port whose settings you want to change, and
then press ENTER.
Make changes in the following submenus:
4.
5.
For each submenu, save the changes by typing the number for the Save
changes and reset HBA option, and then pressing ENTER. This saves your
changes and resets all ports on the HBA.
To update the firmware with these changes, type the number for the Refresh
option, and then press ENTER. If you do not select this option, your changes
will not be visible in SANsurfer iSCSI HBA CLI.
Display Configured Port Settings
When you select the Display Configured Port Settings option, SANsurfer iSCSI
HBA CLI displays a list of port settings, including:
iSCSI settings for instance 0
Firmware settings for instance 0
Device settings for instance 0
SN0054621-00 E
4-23
Download from Www.Somanuals.com. All Manuals Search And Download.
4 – Interactive Mode Commands
Port Level Info & Operations Menu
S
Basic settings for instance 0
Advanced settings for instance 0
Edit a Specific Port Setting
Use the Edit a Specific Port Setting option when you know the name and
parameters of the settings you want to change. For a list of parameter names and
parameters are also available in the following options from the Port Firmware
Settings Menu:
To edit specific HBA settings:
1.
At the following prompt, type the name of the parameter you want to change:
Enter the HBA parameter to modify:
2.
At the following prompt, type the new value:
Enter the HBA parameter value:
The following prompt re-displays:
Enter the HBA parameter to modify:
3.
4.
To modify another parameter, repeat the preceding steps 1 and 2.
When you are done, press ENTERto return to the Port Firmware Settings
Menu.
Configure iSCSI Settings
(CLI Options -n and -nh)
Use the Configure iSCSI Settings menu to modify the following HBA iSCSI
settings:
Force_Negotiate_Main_iSCSI_Keys
iSCSI_Header_Digests
iSCSI_Data_Digests
iSCSI_Immediate_Data
iSCSI_Initial_R2T
iSCSI_Snack
iSCSI_Discovery_Logout
iSCSI_Strict_Login
iSCSI_Alias
4-24
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
4 – Interactive Mode Commands
Port Level Info & Operations Menu
A
Each setting is displayed with the current value in brackets, for example:
iSCSI_Snack [off] :
To change the value, type the new value after the prompt. To keep the current
value, press ENTERat the prompt. The next iSCSI setting appears. The settings
are shown one by one, in the order shown in the preceding list.
Configure Firmware Settings
Use the Configure Firmware Settings option to modify the following firmware
settings:
FW_ZIO_Enable_Mode
AFW_Device_Timeout
AFW_Delayed_Ack
AFW_AutoConnect
Each setting is displayed with the current value in brackets, for example:
AFW_Device_Timeout [on] :
To change the value, type the new value after the prompt. To keep the current
value, press ENTERat the prompt. The next firmware setting appears. The
settings are displayed one-by-one, in the order shown in the preceding list.
Configure Device Settings
Select the Configure Device Settings option to modify the following device
settings:
Large_Frames
ExeThrottle
FirstBurstLen
KeepAliveTO
MAXBurstLen
MAXOutstandingR2T
IPv4TOS
IPv4TTL
Each setting is displayed with the current value in brackets, for example:
FirstBurstLen [256] :
To change the value, type the new value after the prompt. To keep the current
value, press ENTERat the prompt. SANsurfer iSCSI HBA CLI displays the next
device setting. The settings are displayed one by one, in the order shown in the
preceding list.
SN0054621-00 E
4-25
Download from Www.Somanuals.com. All Manuals Search And Download.
4 – Interactive Mode Commands
Port Level Info & Operations Menu
S
Configure Basic Settings
Select the Configure Basic Settings option to modify the following settings
(listed here in alphabetic order):
ENABLE_4022IPv4
ENABLE_IPv4
ENABLE_IPv6
IP_Address
IP_Gateway
IP_Subnet_Mask
IPv6_Addr_Local_Link
iSCSI_Alias
iSCSI_Discovery_Logout
iSCSI_Strict_Login
LDROUTER_AUTO
LOC_LINK_AUTO
ROUTABLE_AUTO
Task_Management_Timeout
TCP_DHCP
TCP_Nagle
Each setting is displayed with the current value in brackets, for example:
Task_Management_Timeout [10] :
To change the value, type the new value after the prompt. To keep the current
value, press ENTERat the prompt. SANsurfer iSCSI HBA CLI displays the next
device setting. The settings are displayed one by one (but not alphabetically, as in
the preceding bullet list).
Configure Advanced Settings
Select the Configure Advanced Settings option to modify the following settings
(listed here in alphabetic order):
AFW_AutoConnect
AFW_Delayed_Ack
AFW_Device_Timeout
AFW_Serlz_Task_Mngmt
ExeThrottle
FirstBurstLen
Force_Negotiate_Main_iSCSI_Keys
FW_ZIO_Enable_Mode
IP_ARP_Redirect
IPv4_TOS_Enable
IPv4TOS
IPv4TTL
4-26
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
4 – Interactive Mode Commands
Port Level Info & Operations Menu
A
IPv6_DAD_Count
IPv6_Hop_Limit
IPv6_MCast_Listnr_Disco_Enable
IPv6_ND_Reachable_Timer
IPv6_ND_Retransmit_Timer
IPv6_ND_Stale_Timeout
IPv6_TCP_Time_Stamp
IPv6_TCP_Window_Scale
IPv6_Traffic_Class
IPv6_VLAN_Enable
IPv6_VLAN_ID
IPv6_VLAN_User_Priority
iSCSI_Data_Digests
iSCSI_Header_Digests
iSCSI_Immediate_Data
iSCSI_Initial_R2T
iSCSI_Name
KeepAliveTO
Large_Frames
MaxBurstLen
MaxOutstandingR2T
TCP_Time_Stamp
TCP_Window_Scale
VLAN_Enable
VLAN_ID
VLAN_User_Priority
ZIO
Each setting is displayed with the current value in brackets, for example:
KeepAliveTO [30] :
To change the value, type the new value after the prompt. To keep the current
value, press ENTERat the prompt. The next setting appears. The settings are
displayed one by one (but not alphabetically, as in the preceding bullet list).
Configure IPv6 Settings
(CLI Options -netconf, -netconf6, -isns, -isns6, -ip, and -nc)
When you select the Configure IPv6 Settings option, SANsurfer iSCSI HBA CLI
shows each current IPv6 setting and gives you the option of entering another:
IPv6_Addr_Local_Link [fe80:2c0:ddff:fe08:e6f6] :_
IPv6_Addr_Routable0 [3ffe:4032:1077:2006:2c0:ddff:fe08:e6f6} :_
IPv6_Addr_Routable1 [::] :_
Default_IPv6_Router [fe80:20d:29ff:fe24:713f] :_
SN0054621-00 E
4-27
Download from Www.Somanuals.com. All Manuals Search And Download.
4 – Interactive Mode Commands
Port Level Info & Operations Menu
S
IPv6_Port [3260] :_
IPv6_Gratuitious_Neighbor_Ad_Enable [off] :_
IPv6_Redirect_Enable [off] :_
Configure IPv6 TCP Settings
Select the Configure IPv6 TCP Settings option to view each current IPv6 TCP
setting and, optionally, changing a setting. For example:
IPv6_Nagle [off] :_
IPv6_TCP_Time_Stamp [on] :_
Legacy QLA4010 Restore Default Port Settings
Select the Legacy QLA4010 Restore Default Port Settings option to reinstate
default port settings to any QLA4010 HBAs in the system. When you enter this
option, the following warning appears:
Warning: This function is resetting the firmware to its default
configuration. These changes will not become permanent until the
HBA settings are saved.
Press the enter key to continue.
Port Restore Factory Defaults
(CLI Option -rdh)
NOTE:
This option is not supported in the QLA4010 HBA.
Use the Port Restore Factory Defaults option to reset the firmware for a single
port to the factory default values. Be sure to select both Save changes and reset
HBA and then Refresh afterwards; otherwise, the changes will not take effect.
This option updates the HBA factory default settings for the following HBA
modules:
Firmware parameters
Network settings (IP, netmask, and so on)
iSCSI name
Target settings
CHAP settings
NVRAM settings
IPsec settings
After selecting this option, you are asked if you want to restore all of the factory
defaults in the preceding list. Do one of the following:
4-28
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
4 – Interactive Mode Commands
Port Level Info & Operations Menu
A
If you want to restore all the defaults, press ENTER.
If you want to restore some of the defaults, type no, and then press ENTER.
Each setting appears one-by-one, in the order listed in the preceding. To
restore the factory default for that setting, type yes, and then press ENTER.
If you do not want to restore this setting, type no, and then press ENTER.
The HBA is reset after the parameters are restored.
CAUTION!
These new settings do not apply to currently configured targets, unless you
delete the targets, and then configure them again after resetting the HBA.
Port Diagnostic Menu
The Port Diagnostic Menu contains the following options:
To use port diagnostics:
1.
Before making a selection on the Port Diagnostic Menu, specify the HBA
port whose settings you want to view or change by typing the number for
Select HBA Port, and then pressing ENTER.
SANsurfer iSCSI HBA CLI lists all iSCSI HBA ports.
2.
3.
Type the number for the HBA port whose settings you want to change, and
then press ENTER.
Make changes in the submenus, as described in the following sections.
SN0054621-00 E
4-29
Download from Www.Somanuals.com. All Manuals Search And Download.
4 – Interactive Mode Commands
Port Level Info & Operations Menu
S
4.
After making changes, refresh the HBA to show these changes by typing 6
(Refresh), and then pressing ENTER. If you do not select this option, your
changes will not be visible in SANsurfer iSCSI HBA CLI.
Ping Target
(CLI Option -ping)
To ping a target:
1.
On the Port Diagnostic Menu, type the number for the Ping option, and
then press ENTER.
SANsurfer iSCSI HBA CLI prompts you as follows:
Enter an IP Address:
2.
3.
4.
Type the target IP address, and then press ENTER.
SANsurfer iSCSI HBA CLI prompts you as follows:
Enter the number of PING attempts to make:
Type a number between 1 and 2147483648 (2^31), and then press ENTER.
SANsurfer iSCSI HBA CLI prompts you as follows:
Enter the packet size in bytes for the PING [32]:
Type the number you want.
For IPv6 networks, SANsurfer iSCSI HBA CLI prompts you as follows:
Which IPv6 address should be used as the source:
0 = Don't Care
1 = Link Local
2 = Address 0
3 = Address 1
Enter Choice:1
Type the number you want.
Here is an example of a successful ping attempt:
Ping to 10.14.64.153 successful <1 of 2>
Ping to 10.14.64.153 successful <2 of 2>
Press the Enter key to continue.
Here is an example of a ping on an IPv6 network:
Enter an IP Address:fe80::2a0:98ff:fe03:c98e
Enter the number of PING attempts to make:1
Enter the packet size in bytes for the PING [32]:
Which IPv6 address should be used as the source:
0 = Don't Care
1 = Link Local
2 = Address 0
3 = Address 1
4-30
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
4 – Interactive Mode Commands
Port Level Info & Operations Menu
A
Enter Choice:1
Ping to fe80::2a0:98ff:fe03:c98e successful (1 of 1).
Press the Enter key to continue.
Perform Loopback Test
(CLI Option -lb)
CAUTION!
Before doing a loopback test, ensure that the HBA does not have any
outstanding I/O operations.
To start a loopback test:
1.
2.
3.
On the Port Diagnostic Menu, type the number for the Perform Loopback
Test option, and then press ENTER.
At the prompt, type the quantity of loopback tests to run. Valid values are in
the range of 1–2147483648 (2^31). By default, one loopback test is run.
Select the loopback test type:
1 (internal)
2 (external)
The default is an internal loopback test.
4.
If you want to stop the loopback test should an error occur, type yfor the
Stop on error[Y]?option.
After the test is complete, SANsurfer iSCSI HBA CLI displays the number of
failed tests and successful tests.
Perform Read/Write Buffer Test
(CLI Option -rwt)
CAUTION!
Before running a read/write buffer test, make sure that the HBA does not
have any outstanding I/O operations.
To start a read/write buffer test:
1.
On the HBA Diagnostic Menu, type the number for the Read/Write buffer
test option, and then press ENTER.
2.
At the prompt, type the number of read/write tests to run. Valid values are in
the range 1–2147483648 (2^31). By default, one test is done.
SANsurfer iSCSI HBA CLI lists the data patterns.
SN0054621-00 E
4-31
Download from Www.Somanuals.com. All Manuals Search And Download.
4 – Interactive Mode Commands
Port Level Info & Operations Menu
S
3.
4.
Type the number corresponding to the data pattern you want, and then
press ENTER.
If you want to stop the loopback test if an error occurs, type yfor the Stop
on error[Y]?option.
After the test is done, the number of failed tests and successful tests are
shown.
Display Port Statistics
(CLI Option -stat)
When you select the Display Port Statistics option, the HBA statistical
information is displayed for the current HBA. For a list of the HBA statistics, see
Reset Statistics
(CLI Option -sreset)
When you select the Reset Statistics option, the HBA port statistics counters are
immediately reset.
Display ARP Table
(CLI Option -arp)
Select the Display ARP Table option to view the Address Resolution Protocol
(ARP) cache, which keeps a record of host port connections with other hardware
(such as targets) on the network. The IP address/MAC address pairs are dynamic
entries that are removed after 10 minutes.
Display Connection Error Log
Select the Display Connection Error Log to view the error log for each HBA
connection. For example:
inst 0 Number of entries = 0xd (13)
=======================
inst 0 Entry Index: 0
=======================
Delta Time (in seconds) : 0.000
Timestamp (or seconds) : Wed May 28, 2008 11:05:41 AM
Target ID
: 2
Original State
Entry Type
Error Type
: Logged in (0x25)
: Sense data (0x4)
: Removable medium changed or the target has been reset
(0x6)
Detail Code
:
power on, reset, or bus device reset occurred (0x2900)
Number Consecutive Errors: 1
and so on.
4-32
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
4 – Interactive Mode Commands
Port Level Info & Operations Menu
A
Export Connection Error Log
When you select the Export Connection Error Log option, SANsurfer iSCSI
HBA CLI prompts you for a file name with which to save the log of connection
errors. Enter a file name and then press ENTER.
Display Neighbor Cache (IPv6)
(CLI Option -nc)
Select the Display Neighbor Cache (IPv6) option to view the IPv6 neighbor
cache. Similar to the ARP table in IPv4, the neighbor cache is a set of entries
about individual neighbors to which traffic has been sent recently. Entries contain
such information as its link-layer address, a flag indicating whether the neighbor is
a router or a host, a pointer to any queued packets waiting for address resolution
to complete, and so forth.
Display Destination Cache (IPv6)
(CLI Option -dc)
Select the Display Destination Cache (IPv6) option to view the IPv6 destination
cache containing the IP address, next-hop IP address, and path MTU information
about both local and remote destinations. For multicast and on-link unicast
destinations, the next-hop IP address always matches the destination IP address.
For unicast destinations that are off-link, the next hop IP address is the IP address
of the router.
Display Default Router List (IPv6)
(CLI Option -dr)
Select the Display Default Router List (IPv6) option to view the IPv6 default
router list, which includes both the active default router and a short list of other
routers that advertised themselves as being able to act as a default router. The
active default router always appears first in the list.
Display Local Prefix List (IPv6)
(CLI Option -lp)
Select the Display Local Prefix List (IPv6) to view the IPv6 local-prefix list
created by the HBA from prefix information in router advertisements. The HBA
can reach destination IP addresses containing these prefixes directly, without
going through an intermediate router.
The following shows how a typical list may look:
Local Prefix Entry number 0
Preferred Lifetime <secs> - 604669
Valid Lifetime <secs> = 2591869
Prefix = 3ffe:4032:1077:2006
Update time <from FW boot> = 514 seconds, 0 milliseconds
Update time <from FW boot> = 8 mins 34 secs 0 millisecs
Update time
= Mon Apr 23 17:17:30 2007
SN0054621-00 E
4-33
Download from Www.Somanuals.com. All Manuals Search And Download.
4 – Interactive Mode Commands
Port Level Info & Operations Menu
S
FW Boot time
= Mon Apr 23 17:08:56 2007
BIOS/UEFI [or FCode] Settings Menu
SANsurfer iSCSI HBA CLI detects the system architecture and shows this menu
as either BIOS/UEFI Settings Menu or FCode Settings Menu, depending on
your system. On Intel type machines, the BIOS/UEFI Settings Menu appears; on
PPC and SPARC, the FCode Settings Menu appears.
NOTE:
If the BIOS version is less than 1.04, the Set BIOS/UEFI Mode option is not
supported (an error message is shown).
To edit the HBA BIOS/UEFI or FCode settings:
1.
From the PORT BIOS/UEFI Settings Menu or PORT FCode Settings
Menu, specify the HBA port whose settings you want to view or change by
typing the number for Select HBA Port, and then pressing ENTER.
SANsurfer iSCSI HBA CLI lists all iSCSI HBA ports.
2.
3.
Type the number for the HBA port whose settings you want to change, and
then press ENTER.
Select the following submenus to view or make changes to the HBA
bootcode settings:
4.
5.
For each submenu, save the changes by selecting Save changes option.
This saves your changes and resets all ports on the HBA.
You must select Refresh to update the firmware with these changes and
make them visible in SANsurfer iSCSI HBA CLI.
4-34
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
4 – Interactive Mode Commands
Port Level Info & Operations Menu
A
Display BIOS/UEFI [or FCode] Information
(CLI Option -binfo)
Select the Display BIOS/UEFI Information or Display FCode Information
option (this menu option varies depending on your system architecture) to view
information about the bootcode. For example:
BIOS Mode: Disabled (0x1)
BIOS Primary Target ID: 2
BIOS Secondary Target ID: 2
BIOS Vendor ID =
LUN: 0
LUN: 0
BIOS Alt Client ID = testod
BIOS Version: 1.14
BIOS Full Version: 1.14
Set BIOS/UEFI [or FCode] Mode
(CLI Option -bootcodemode)
NOTE:
If the BIOS version is less than 1.04, this option is not supported (it displays
an error message).
Select the Set BIOS/UEFI Mode or Set FCode Mode option (depending on your
system architecture) to select the bootcode mode. For example:
Choose from one of the following modes:
1) BIOS/UEFI [or FCode] Boot Disabled
2) BIOS/UEFI [or FCode] Boot Manual Mode
3) BIOS/UEFI [or FCode] Boot DHCP-Root Path
Set Primary Boot Target Information
(CLI Option -pbootcode)
Select the Set Primary Boot Target Information option to select the primary
target to boot from. At the prompt, type a target ID and associated LUN.
Set Secondary Boot Target Information
(CLI Option -sbootcode)
Select the Set Secondary Boot Target Information option to select the
secondary target to boot from. At the prompt, type a target ID and associated
LUN.
SN0054621-00 E
4-35
Download from Www.Somanuals.com. All Manuals Search And Download.
4 – Interactive Mode Commands
Port Level Info & Operations Menu
S
Clear Primary Boot Target Information
(CLI Option -cpbootcode)
Select the Clear Primary Boot Target Information option to disable the primary
boot target. At the prompt, type a target ID and associated LUN.
Clear Secondary Boot Target Information
(CLI Option -csbootcode)
Select the Clear Secondary Boot Target Information option to disable the
secondary boot target. At the prompt, type a target ID and associated LUN.
Set Alternative Client ID
(CLI Option -sbootcodecid)
Select the Set Alternative Client ID option to assign an optional alternative client
ID, which can be used in boot DHCP mode. The ID can be seven characters
maximum.
Target Level Info & Operations
Before making a selection from the HBA Target Menu, follow these steps:
1.
Specify the HBA port whose settings you want to view or change by typing
the number for Select HBA Port, and then press ENTER.
A list of HBA ports is displayed.
2.
3.
Type the number for the HBA port whose settings you want to change, and
then press ENTER.
To make changes, select options from the following submenus:
4-36
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
4 – Interactive Mode Commands
Port Level Info & Operations Menu
A
4.
5.
For each submenu, save the changes by typing the number for the Save
Target/CHAP changes option, and then pressing ENTER.
Type the number for the Refresh option, and then press ENTER. If you do
not select this option, your changes will not be visible in SANsurfer iSCSI
HBA CLI.
List Targets
(CLI Option -t)
To list all targets connected to the current working adapter, type the number for
the List Targets option, and then press ENTER. The following information is
displayed for each target:
Target ID (target ID of this device as assigned by the QLogic tool)
HBA number
IP (IP address of the target)
Port instance (port ID for iSCSI devices, as defined by the iSCSI standard)
iSCSI name (target iSCSI name, as defined by the iSCSI standard)
Alias (target iSCSI alias name, as defined by the manufacturer software)
State (of the target session connection). Session states include:
Unassigned
No Connection
Discovering
Not Saved
No Session
Session Active
Logged out
Session Failed
Unknown
Display Target Information
(CLI Option -t)
Select the Display Target Information option to view the same information
shown for the List Targets option. At the Enter a Target ID:prompt, type
the ID of the target for which you want to see more detailed information, and then
press ENTER.
The following shows an example of target information:
Target ID: 2 hba_no: 5 IP: 10.14.64.154 Port: 3260 TGT Instance #: 2
ISCSI Name: iqn.1987-05.com.cisco:00.28182218624e.chap4
Alias: chap4
State: Session Active
TGT_iSCSI_Name
iqn.1987-05.com.cisco:00.28182218624e.chap4
TGT_Target_ID : 2(*)
:
SN0054621-00 E
4-37
Download from Www.Somanuals.com. All Manuals Search And Download.
4 – Interactive Mode Commands
Port Level Info & Operations Menu
S
TGTO_Active
: off(*)
: off(*)
: on(*)
: off(*)
: 0(*)
: 0(*)
: 0(*)
: 64
TGTO_Access_Granted
TGTO_Target_Entry
TGTO_Initiator_Entry
TGT_RetryCount
TGT_RetryDelay
TGT_DevType
TGT_ExeThrottle
TGT_FirstBurstLen
: 128
TGTIPO_Fragmentation
TGTISCSIO_Force_Neg_Main_Keys
TGTISCSIO_Send_Markers
TGTISCSIO_Header_Digests
TGTISCSIO_Data_Digests
TGTISCSIO_Immediate_Data
TGTISCSIO_Initial_R2T
TGTISCSIO_Data_Sequence_In_Order
TGTISCSIO_Data_PDU_In_Order
TGTISCSIO_CHAP_Authentication
: on(*)
: off
: off(*)
: off
: off
: on
: on
: on(*)
: on(*)
: on
TGTISCSIO_Bidi_CHAP_Authentication : off
TGTISCSIO_Snack
: off
TGTISCSIO_Discovery_Logout
TGTISCSIO_Strict_Login
TGTISCSIO_Error_Recovery_Level
TGT_KeepAliveTimeout
TGT_DefaultTimeout
TGT_DefaultTime2Retain
TGT_MaxBurstLen
: on
: off
: 0(*)
: 30
: 2
: 20(*)
: 512
TGT_MaxOutstandingR2T
TGT_MaxRxDataSegmentLen
TGT_MaxTxDataSegmentLen
TGT_Port
: 1
: 128(*)
: 0(*)
: 3260
: off
TGTTCPO_Nagle
TGTTCPO_Timer_Scale
TGTTCPO_Timestamp
: 3(*)
: on
TGT_TaskManagementTimeout
TGT_ExeCount
: 10
: 0(*)
: 1(*)
: 0x00c0dd085a39
TGT_TargetPortalGroupID
TGT_InitiatorSessID
4-38
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
4 – Interactive Mode Commands
Port Level Info & Operations Menu
A
TGT_TargetSessID
: 5(*)
TGT_TargetIPAddress
TGT_Window_Scale_Enable
TGT_Rx_Window_Scale
TGT_Tx_Window_Scale
TGT_TimeStamp_Enable
TGT_DDB_IPv6
: 10.14.64.154
: on
: 0
: 2(*)
: 64(*)
: off
TGT_IPv6_Address
: a0e:409a::
: 29251(*)
: 0
TGT_Local_TCP_Port
TGT_Type_of_Service
TGT_Traffic_Class
: 0(*)
TGT_Local_IPv6_Address
TGT_4022_Deleyed_ACK
TGT_Redirect_IPAddr
Values noted with (*) are read only.
Press the Enter key to continue.
: ::(*)
: off
: 10.14.64.154
For a complete list of target parameters, their aliases, functions, and values, see
Bind Target
(CLI Option -pb)
Select the Bind Target option to persistently bind a specific target to the HBA port
by saving it in the HBA flash. Targets that are not persistently bound will not
persist across firmware resets or HBA power cycles.
When you select this option, SANsurfer iSCSI HBA CLI lists available targets. At
the Enter a Target ID:prompt, type the target ID of the target you want to
bind.
Delete Target
Select the Delete Target option to remove a target from the HBA database.
Configure Target Parameters
(CLI Option -tc)
Select the Configure Target Parameters option to configure various target
parameters. For a list of target parameters by their configuration names,
Each setting is displayed with the current value in brackets, for example:
TGT_DefaultTimeout [120] :
To change the value, type the new value after the prompt. To keep the current
value, press ENTERat the prompt. SANsurfer iSCSI HBA CLI automatically
displays the next target parameter.
SN0054621-00 E
4-39
Download from Www.Somanuals.com. All Manuals Search And Download.
4 – Interactive Mode Commands
Port Level Info & Operations Menu
S
Add a Target
(CLI Option -pa)
Select the Add a Target option to add a new target to the current working adapter.
When prompted, type the following information for the new target; the parameters
are displayed one at a time:
TGT_iSCSI_Name (target iSCSI name)
TGT_Port (target port)
TGT_TargetIPAddress (target IP address)
If you do not enter the TGT_iSCSI_Name, the default is an empty string. If you do
not enter the TGT_Port number, the default is 3260.
Disable a Target
Select the Disable a Target option to disconnect the target and disable future
connections until you re-enable it. The target remains in the HBA database.
Enable a Target
Select the Enable a Target option to re-enable the target and re-establish the
connection, if possible.
Configure Target Authentication Menu
The iSCSI HBA firmware uses the challenge handshake authentication protocol
(CHAP) as an authentication mechanism between the iSCSI initiators (QLA4xxx
HBA ports) and the targets to which they are attached. Authentication can be
disabled or enabled for a specific target or for all targets attached to the QLA4xxx
HBA port.
To configure target authentication (CHAP):
1.
If you have not already, specify the HBA port whose settings you want to
view or change by typing the number for Select HBA Port, and then
pressing ENTER.
SANsurfer iSCSI HBA CLI lists all iSCSI HBA ports.
2.
Type the number for the HBA port whose settings you want to change, and
then press ENTER.
4-40
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
4 – Interactive Mode Commands
Port Level Info & Operations Menu
A
3.
From the HBA CHAP Menu, make changes as needed by selecting from
the following options:
Display CHAP Table
(CLI Option -dspchap)
Select the Display CHAP Table option to view the CHAP table, which is an array
of records containing CHAP names and secrets used by the HBA during CHAP
authentication. For example:
CHAP TABLE
Entry: 1 <DEFAULT BIDI CHAP entry>
Name:
Secret: jonathan
This is a BIDI Chap entry
Entry: 2
Name: tyler
Secret: qlogic
Entry: 4
Name: randy
Secret: qlogic
Press the Enter key to continue.
Display Targets Using CHAP Entries
(CLI Option -chapmap)
Select the Display Targets Using CHAP Entries option to view the following
information about each target that has a CHAP:
Target ID (target ID of this target as assigned by QLogic software)
IP address (IP address of the target)
Port (port ID for iSCSI targets as defined by the iSCSI standard)
iSCSI name (target iSCSI name as defined by the iSCSI standard)
Alias (target iSCSI alias name as defined by the manufacturer software)
SN0054621-00 E
4-41
Download from Www.Somanuals.com. All Manuals Search And Download.
4 – Interactive Mode Commands
Port Level Info & Operations Menu
S
Name (CHAP name)
Secret (CHAP secret)
Assign a CHAP Entry to a Target
(CLI Option -linkchap)
To assign a CHAP entry to a target:
1.
2.
3.
On the HBA CHAP Menu, type 3(Assign a CHAP Entry to a Target).
SANsurfer iSCSI HBA CLI lists available targets.
Type the target ID of the target you want, and then press ENTER.
The CHAP table is displayed.
At the prompt CHAP Entry Number <0 for no CHAP>, do one of the
following:
Type the entry number for one of the entries in the displayed CHAP
table, and then press ENTER.
Type 0if you do not want to assign a CHAP entry to this target, and
then press ENTER.
Add a CHAP Entry
(CLI Option -addchap)
To add an entry to the CHAP table:
1.
2.
3.
4.
On the HBA CHAP Menu, type 4(Add a CHAP entry), and then press
ENTER.
At the CHAPNameprompt, type a name for the CHAP entry, and then press
ENTER. The CHAP name can be up to 256 bytes long.
At the CHAPSecretprompt, type a secret for the CHAP entry, and then
press ENTER. The CHAP secret can be up to 100 bytes long.
The CHAPBidi [off]prompt displays. Do one of the following:
If you want the HBA to authenticate the target (bidirectional CHAP),
type yes, and then press ENTER.
If you do not want the HBA to authenticate the target, either press
ENTER(the default) or type off, and then press ENTER. You can also
To view a map of targets to CHAP table entries, use the -chapmapcommand.
4-42
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
4 – Interactive Mode Commands
Port Level Info & Operations Menu
A
Add a Default BIDI CHAP
(CLI Option -defbidi)
A default bidirectional (BIDI) CHAP causes the HBA to authenticate only the
CHAP secrets of all targets with CHAP (the CHAP names are ignored). In
addition, the CHAP names of any bidirectional CHAP entries are ignored.
To add a default BIDI CHAP:
1.
On the HBA CHAP Menu, type 5(Add a Default BIDI CHAP), and then
press ENTER.
2.
At the CHAPSecret [default secret]prompt, do one of the following:
Type the name of an existing CHAP secret you want to use, and then
press ENTER.
To use the default secret displayed in the prompt, press ENTER.
3.
At the Press the Enter key to continueprompt, press ENTER.
Edit a CHAP Entry
(CLI Option -edchap)
To edit a CHAP entry:
1.
On the HBA CHAP Menu, type 6(Edit a CHAP entry), and then press
ENTER.
The CHAP table is displayed.
2.
3.
Press ENTER.
At the prompt, type the number of the CHAP entry you want to change, and
then press ENTER.
4.
At the CHAPName [default name]prompt, do one of the following:
Type a new CHAP name, and then press ENTER.
To use the default CHAP name shown in the prompt, press ENTER.
5.
At the CHAPSecret [default name]prompt, do one of the following:
Type a new CHAP secret, and then press ENTER.
To use the default CHAP secret shown in the prompt, and then press
ENTER.
6.
At the CHAPBidi [offor on]prompt, do one of the following:
If you want the HBA to authenticate the target (bidirectional CHAP)
and the prompt is CHAPBidi [off], type on, and then press ENTER.
If the prompt is CHAPBidi [on], press ENTER.
SN0054621-00 E
4-43
Download from Www.Somanuals.com. All Manuals Search And Download.
4 – Interactive Mode Commands
Port Level Info & Operations Menu
S
If you do not want the HBA to authenticate the target and the prompt is
CHAPBidi [off], press ENTER. If the prompt is CHAPBidi [on],
type off, and then press ENTER.
Delete a CHAP Entry
(CLI Option -delchap)
To delete an entry from the CHAP table:
1.
Type 7(Delete a CHAP entry), and then press ENTER.
The CHAP table is displayed.
2.
3.
Press ENTER.
At the prompt, type the entry number of the CHAP you want to delete, and
then press ENTER.
4.
Press ENTERagain.
Save Target/CHAP Changes
(No CLI Option)
Target Discovery Menu
The Target Discovery Menu provides options that enable you to:
Discover targets without logging in.
Login a selected target and persist, if desired.
Duplicate a target login using a new ISID to enable multi-pathing and
failover.
NOTE:
Targets entered and discovered using this set of menu options are kept in a
database local to SANsurfer iSCSI HBA CLI. Because discovered targets
are not kept in the HBA, they do not transport across applications. Targets
Level Info & Operations” on page 4-36) are also listed here, but those
targets are kept in the HBA database and so are considered persistent.
4-44
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
4 – Interactive Mode Commands
Port Level Info & Operations Menu
A
Select the Target Discovery Menu option to view the HBA Target Discovery
Menu containing the following options:
Display Send Targets
Select the Display Send Targets option to view a list of send targets in the
SANsurfer iSCSI HBA CLI database, as well as the persistent send targets in the
HBA database.
Display Discovered Targets
Select the Display Discovered Targets option to view a list of discovered targets
in the SANsurfer iSCSI HBA CLI database.
Add a Send Target
Select the Add a Send Target option to add a new send target to either the
SANsurfer iSCSI HBA CLI database or the HBA database. You must save your
changes before send targets are discovered. When you are prompted to make the
target persistent, respond yesto add the target to the HBA database and log in
the targets. For the added target to be discovered, you must use the Save
Mark Send Target for Re-discovery
Select the Mark Send Target for Re-discovery option to have SANsurfer iSCSI
HBA CLI discover send targets when you select the Save Target/CHAP Settings
SN0054621-00 E
4-45
Download from Www.Somanuals.com. All Manuals Search And Download.
4 – Interactive Mode Commands
Port Level Info & Operations Menu
S
Remove a Send Target
Select the Remove a Send Target option to remove only non-persistent or send
targets local to the SANsurfer iSCSI HBA CLI database. To remove targets stored
Remove a Send Target option does not require a save to take effect.
Login and Persist a Discovered Target
Select the Login and Persist a Discovered Target option to log in and persist a
target that has been discovered but not yet logged in. Before this option can take
Duplicate a Persistent Target
Select the Duplicate a Persistent Target option to copy a target in the HBA
database and assign a new ISID to the new target. You can use the duplicate
target for multi-pathing/failover. Before this option can take effect, you must select
Duplicate a Discovered Target
Select the Duplicate a Discovered Target option to copy a discovered target that
is not logged in. This option does not require a save to take effect.
Remove Discovered Target
Select the Remove Discovered Target option to remove a target that is
discovered and persisted. To remove targets stored in the HBA database, use the
option does not require a save to take effect.
Display iSNS Settings
Select the Display iSNS Settings option to view the settings for the currently
configured iSNS. This option functions the same as “Display Network Settings
Configure iSNS
Select the Configure iSNS option to set up iSNS. This option functions the same
discovered targets are shown with the other discovered targets. You can also log
in those targets using the Configure iSNS option.
4-46
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
4 – Interactive Mode Commands
Port Level Info & Operations Menu
A
List LUN Information
(CLI Option -l)
Select the List LUN Information option to view the following information about
LUNs attached to the selected target:
HBA/Target/LUN Number
Vendor name
Product ID
Product revision
LUN size
You can view this information for a specific LUN or for all LUNs attached to the
selected target. For example:
iSCSI HBA Target Menu
HBA Target Menu
…
Enter selection: 7
Target ID: 64
3260
IP: 192.166.1.41
Port:
iSCSI Name: iqn.1992-08.com.netapp:sn.51403494
Alias:drive4
State:Session Active
…
Enter a Target ID:64
Enter a LUN Number[60.64,65,63,66,100,103,105,104,50,<ALL>]:63
Vend
= NETAPP
= LUN
ProdID
ProdRv
LunSize
= 0.2
= 4.999 GB
Press the Enter key to continue.
Save Target/CHAP Changes
(No CLI Option)
Select the Save Target/CHAP Changes option to save any changes you made to
the target or CHAP settings.
SN0054621-00 E
4-47
Download from Www.Somanuals.com. All Manuals Search And Download.
4 – Interactive Mode Commands
List All QLogic iSCSI HBA Ports Detected (CLI Option -i)
S
List All QLogic iSCSI HBA Ports Detected
(CLI Option -i)
Select the List All QLogic iSCSI HBA Ports Detected option to view the
following information for all HBA ports in the system:
HBA model (HBA name, for example, QLA4010)
HBA serial number
HBA port number
Firmware (FW) version
Type (Connection medium: copper or fiber)
iSCSI name (HBA port iSCSI name). Manufacturer’s default or name you
assign.)
Alias (HBA port iSCSI alias name. Symbolic name you assign to the HBA.)
IP address (IP address of the HBA port)
Instance (driver ID number)
For example:
1. HBA: 0 Port: 0 HBA Port Index: 1 HBA Model: QLA4050C
HBA Serial Number: (FS10506A02810) FW Version: 2.2.4.45 Type: Copper
IP Address: 192.168.104.129
Alias:
iSCSI name: iqn.2000-04.com.qlogic.qla4050c.fs10506a02810.1
2. HBA: 1 Port: 0 HBA Port Index: 2 HBA Model: QLA4062C
HBA Serial Number: (AS40637A00081)
IP Address: 192.168.104.139
Alias:
FW Version: 3.0.1.18 Type: Copper
iSCSI name: iqn.2000-04.com.qlogic.qle4062c.as40637a00081.1
3. HBA: 1 Port: 1 HBA Port Index: 3 HBA Model: QLA4062C
HBA Serial Number: (AS40637A00081) FW Version: 3.0.1.18 Type: Copper
IP Address: 192.168.104.140
Alias:
iSCSI name: iqn.2000-04.com.qlogic.qle4062c.as40637a00081.2
4. HBA: 2 Port: 0 HBA Port Index: 4 HBA Model: QLA4010
HBA Serial Number: (FS10506A02810) FW Version: 2.2.4.45 Type: Copper
IP Address: 0.0.0.0
Alias:
iSCSI name: iqn.1991-05.com.microsoft:steinway.qlogic.org
4-48
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
4 – Interactive Mode Commands
Help (CLI Option -h)
A
Help
(CLI Option -h)
Select the Help option to view the SANsurfer iSCSI HBA CLI help file, which
contains a list of non-interactive mode commands and the syntax of each.
Select HBA Port
(No CLI Option)
Select the Select HBA Port option to get a list of all installed HBAs and their
parameters, including the following information:
HBA number (in this system)
HBA Port Index (which port this is in the list of all system iSCSI ports)
HBA model (for example, QLA4052C)
HBA serial number
Firmware version
Type of connection (Copper or Optical)
IP Address
Alias
iSCSI Name
The display looks similar to the following:
1. HBA: 0 Port: 0
HBA Port Index: 1 HBA Model: QLA4050C
HBA Serial Number: (FS10506A02810)FW Version: 2.2.4.45 Type: Copper
IP Address: 192.168.104.129
Alias:
iSCSI name: iqn.2000-04.com.qlogic.qla4050c.fs10506a02810.1
Type the Port Index number for the HBA Port Instance you want to view or
change, and then press ENTER.
Refresh
(No CLI Option)
To update the firmware with the changes made on this menu, and to be sure you
can see your changes in the CLI, type the number for the Refresh option, and
then press ENTER.
SN0054621-00 E
4-49
Download from Www.Somanuals.com. All Manuals Search And Download.
4 – Interactive Mode Commands
Exit (No CLI Option)
S
Exit
(No CLI Option)
To return to the next higher level (parent) menu, type the number for Exit, and
then press ENTER. If you are at the top-level of the interactive menu, the CLI offers
you the option to save or discard any changes you made, and then closes.
4-50
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
5 Non-Interactive Mode
Commands
Use non-interactive commands in scripts and similar applications to configure
QLogic QLA4xxx iSCSI HBAs and the storage connected to them. If you prefer to
work with the HBA from a menu-based system, use Interactive mode commands
The command format for non-interactive mode is:
iscli [optional parameters] <Command Option> [Command Variable] |
[Command Variable]
Where:
<> = Parameters in angled brackets are required.
[] = Parameters in square brackets are optional.
| = OR operator.
Italicized text = Placeholder describing the command variable.
SN0054621-00 E
5-1
Download from Www.Somanuals.com. All Manuals Search And Download.
5 – Non-Interactive Mode Commands
S
apply. describes command-specific variables.
Table 5-1. Non-interactive Command Variables
Variable Definition
hba_port_inst The system port (formerly HBA number)
Target ID Target ID
LUN ID Logical unit number (0–255)
CHAP Number Challange handshake authentication protocol (CHAP) num-
ber
CHAP Name Null-terminated CHAP name, which is sent by the port
instance when responding to the CHAP challenge
CHAP Secret CHAP secret, which is used by the port instance when gener-
ating the CHAP response
Boot Target The target ID of the target device from which to boot
Boot LUN The LUN of the boot device
NOTE:
The commands are case sensitive. For example, -gis not the same as
-G.
Only one command line option per input file is valid.
<hba_port_inst> is an instance number from the list of all iSCSI HBA
ports in the system. You can see this list with the command -i.
The positional parameters vary, depending on the command option specified. For
example, to display an HBA’s configured settings, use the command option -C,
followed by the port instance number (positional parameter). In contrast, the
command for providing general information, -g, has no positional parameters.
In non-interactive mode, most changes made to the port instance become
effective immediately. This sometimes will cause the HBA to reset, as specified in
the command description. Be sure the system is prepared for a HBA reset before
making changes.
5-2
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
5 – Non-Interactive Mode Commands
Non-interactive Commands
A
Non-interactive Commands
This section contains an alphabetical list of the SANsurfer iSCSI HBA CLI
commands used in non-interactive mode.
-acb
To inquire whether the ACB (access method control block) firmware functions are
supported, enter the -acbcommand. In general, up-to-date firmware and driver
are required for ACB to be supported.
-addchap
(Add a CHAP Entry)
To add a CHAP entry to the persistent CHAP table, enter the -addchap
command as follows:
-addchap [-BIDI] <hba_port_inst> <CHAP Name> <CHAP Secret>
The optional parameter [-BIDI]shows that the CHAP entry is BIDI
(bidirectional). When this parameter is not specified (default), the CHAP entry is
local.
Issuing this command resets the HBA. For more information on CHAP and the
interactive version of this command, see “Add a CHAP Entry (CLI Option
-arp
(Display ARP Table)
The Address Resolution Protocol (ARP) cache keeps a record of host port
connections with other hardware (such as targets) on the network. The IP
address/MAC address pairs are dynamic entries that are removed after 10
minutes. To view the ARP table, enter the -arpcommand as follows:
-arp <hba_port_inst>
For information on the interactive version of this command, see “Display ARP
-b
(HBA Reset)
To reset the specified HBA after making configuration changes, enter the -b
command as follows:
-b <hba_port_inst>
SN0054621-00 E
5-3
Download from Www.Somanuals.com. All Manuals Search And Download.
5 – Non-Interactive Mode Commands
Non-interactive Commands
S
NOTES:
Issuing this command resets both ports (0 and 1) on two-port HBAs.
For information on the interactive version of this command “HBA Reset (CLI
-binfo
(Display BIOS/UEFI [or FCode] Information)
To display the bootcode settings for the specified HBA port, enter the -binfo
command as follows:
-binfo <hba_port_inst>
For information on the interactive version of this command, see “Display
-bootcode
(Update BIOS/UEFI [or FCode] Mode)
Bootcode (that is, the bootable code image) is code that allows system boot from
an iSCSI drive.
The -bootcodecommand updates the bootcode code image, which should be
done when QLogic releases a new bootcode with bug fixes or enhancements. At
the prompt, type the name of the file containing the bootcode code image to
upload to the HBA.
For information on bootcode file names, see Appendix E Downloadable File
To update the bootcode code image, enter the -bootcodecommand as follows:
-bootcode <hba_port_inst> <Bootcode Code Image File Name>
For information on the interactive version of this command, see “Update
-bootcodemode
(Set BIOS/UEFI [or FCode] Mode)
To set the bootmode mode for QLA4050, QLA4050C, QLE4060C, QLE4062, and
QMC4052 HBAs, enter the -bootcodemodecommand as follows:
-bootcodemode <hba_port_inst> <1>|<2>|<3>
5-4
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
5 – Non-Interactive Mode Commands
Non-interactive Commands
A
Where:
1 = Disabled
2 = Manual mode
3 = DHCP–Root path
modes 1–3 are allowed. If HBA DHCP is not enabled, bootcode DHCP is not
allowed. This mode is not supported for QLA4010 HBAs. This mode is not active
for the PPC.
For IBM cards, the following modes are available:
4 = DHCP Vendor ID
5 = DHCP-Auto
6 = Auto
7 = System Mode
For information on the interactive version of this command, see “Set BIOS/UEFI
NOTE:
Bootcode DHCP is not allowed for QLA4010 HBAs.
-c
(Display Configured Port Settings)
To view the configured settings for the port, enter the -ccommand as follows:
-c [hba_port_inst]
When you specify a port instance, information for only that HBA is shown. When
you do not specify a port instance, information for all HBA ports in the system is
shown.
For a list of HBA settings, see “Display Configured Port Settings (CLI Option -c)”
-ch
(HBA Information)
To display the HBA’s configured settings, enter the -chcommand as follows:
-ch [hba_port_inst]
When you specify a port instance, information for only that HBA is shown. When
you do not specify a port instance, information for all HBA ports in the system is
shown.
SN0054621-00 E
5-5
Download from Www.Somanuals.com. All Manuals Search And Download.
5 – Non-Interactive Mode Commands
Non-interactive Commands
S
For information on the interactive version of this command, see “HBA Information
-chapmap
(Display Targets Using CHAP Entries)
To display the map of targets to CHAP table entries, enter the -chapmap
command as follows:
-chapmap <hba_port_inst>
-cpbootcode
(Clear Primary Boot Target Information)
To clear the primary boot target and LUN, enter the -cpbootcodecommand as
follows:
-cpbootcode <hba_port_inst>
For information on the interactive version of this command, see “Clear Primary
NOTE:
This command is not active for the PPC.
-csbootcode
(Clear Secondary Boot Target Information)
To clear the secondary boot target and LUN, enter the -csbootcodecommand
as follows:
-csbootcode <hba_port_inst>
For information on the interactive version of this command, see “Clear Secondary
-d
(Install HBA Driver, All Adapters)
To install an HBA driver for all iSCSI HBAs on the system from a .zipor .inf
file, enter the -dcommand as follows:
-d <File Name>
A system reboot may be required; see the log file for details.
5-6
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
5 – Non-Interactive Mode Commands
Non-interactive Commands
A
For information on the interactive version of this command, see “Install HBA
-dc
(Display Destination Cache [IPv6 only])
The IPv6 destination cache contains the IP address, next-hop IP address, and
path MTU information about both local and remote destinations. For multicast and
on-link unicast destinations, the next-hop IP address always matches the
destination IP address. For unicast destinations that are off-link, the next hop IP
address is the IP address of the router.
To display the destination cache, enter the -dccommand as follows:
-dc <hba_port_inst>
For information on the interactive version of this command, see “Display
-dce
To display the connection error logs for up to 100 latest connections, enter the
-dce command as follows:
-dce <hba_port_inst> <target_id> <filename>
If <hba_port_inst>and <target_id>are not specified, all entries for all HBA
ports will be displayed. If <filename>is specified, then the log will be written to
that file.
-defbidi
(Add a Default BIDI CHAP)
To add a default BIDI (bidirectional) CHAP entry to the specified HBA port, enter
the -defbidicommand as follows:
-defbidi <hba_port_inst> <CHAP Secret>
Issuing this command resets the HBA.
For information on the interactive version of this command, see “Add a Default
-delchap
(Delete a CHAP Entry)
To delete the specified CHAP entry, enter the -delchapcommand as follows:
-delchap <hba_port_inst> <CHAP>
Issuing this command resets the HBA.
For information on the interactive version of this command, “Delete a CHAP Entry
SN0054621-00 E
5-7
Download from Www.Somanuals.com. All Manuals Search And Download.
5 – Non-Interactive Mode Commands
Non-interactive Commands
S
-df
To view the firmware properties, enter the -dfcommand as follows:
-df <hba_port_inst>
SANsurfer iSCSI HBA CLI displays information about the HBA: model, serial
number, port number, iSCSI name, alias, IP address, instance number, and the
following firmware information:
FW information for instance
FW version
FW attribute
FW version 2
FW attribute 2
There is no corresponding command in the interactive menu.
-dp
Use the -dpcommand to pre-install an HBA driver specified from a .zip
or .inffile. This operation may be performed without an HBA installed in the
system.
You can specify the following actions:
p— Pre-install driver package (default)
i— Install driver package
u— Uninstall driver package
g— Get driver package path
You may also specify the following flags:
DRIVER_PACKAGE_FORCE
DRIVER_PACKAGE_LEGACY_MODE
DRIVER_PACKAGE_ONLY_IF_DEVICE_PRESENT
DRIVER_PACKAGE_REPAIR
DRIVER_PACKAGE_SILENT
You may need to reboot the system following this command. For details about the
success or failure of the driver update operation, view the trace log file (see
-dr
(Display Default Router List [IPv6 only])
The IPv6 default router list includes both the active default router and a short list
of other routers that advertised themselves as capable of acting as a default
router. The active default router always appears first in the list.
To view the default router list, enter the -drcommand as follows:
5-8
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
5 – Non-Interactive Mode Commands
Non-interactive Commands
A
-dr <hba_port_inst>
For information on the interactive version of this command, “Display Default
-dspchap
(Display a CHAP Table)
To view the CHAP table, enter the -dspchapcommand as follows:
-dspchap <hba_port_inst>
For information on the interactive version of this command, see “Display CHAP
-dtdsp
(Display Discovered Targets)
To view the discovered targets that are not persistent, enter the -dtdsp
command as follows:
-dtdsp <hba_port_inst>
For information on the interactive version of this command, “Display Discovered
-dtdspa
(List Targets)
To view discovered targets, including persistent and non-persistent, enter the
-dtspacommand as follows:
-dtspa <hba_port_inst>
-dtdupd
(Duplicate a Discovered Target)
To duplicate a discovered target that is not persistent, enter the -dtdupd
command as follows:
-dtupd <hba_port_inst> <target_instance>
A duplicate target is assigned a new iSCSI initiator ID (ISID) and can then be used
to create a redundant path.
For information on the interactive version of this command, “Duplicate a
SN0054621-00 E
5-9
Download from Www.Somanuals.com. All Manuals Search And Download.
5 – Non-Interactive Mode Commands
Non-interactive Commands
S
-dtdupd
(Duplicate a Persistent Target)
To duplicate a discovered target that is persistent, enter the -dtdupdcommand
as follows:
-dtdupd <hba_port_inst> <target_id>
A duplicate target is assigned a new iSCSI initiator ID (ISID) and can then be used
to create a redundant path.
For information on the interactive version of this command, “Duplicate a Persistent
-dtli
(Login and Persist a Discovered Target)
To log in a specific discovered target, enter the -dtlicommand as follows:
-dtli <hba_port_inst> <target_instance>
For information on the interactive version of this command, “Login and Persist a
-dtlia
(Login and Persist a Discovered Target)
To log in all discovered targets, enter the -dtliacommand as follows:
-dtlia <hba_port_inst>
For information on the interactive version of this command, “Login and Persist a
-dtrem
(Remove Discovered Target)
To remove a non-persistent discovered target, enter the -dtremcommand as
follows:
-dtrem <hba_port_inst> <target_instance>
For information on the interactive version of this command, “Remove Discovered
5-10
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
5 – Non-Interactive Mode Commands
Non-interactive Commands
A
-dtrema
(Remove Discovered Target)
To remove all non-persistent discovered targets, enter the -dtremacommand as
follows:
-dtrema <hba_port_inst>
For information on the interactive version of this command, “Remove Discovered
-dumpcore
(Retrieve FW Coredump Record)
To dump the RAM memory to a file name of your choice, enter the -dumpcore
command as follows:
-dumpcore <hba_port_inst> [File name]
For information on the interactive version of this command, see “Retrieve FW
-dumpnvram
(Retrieve FW Flash & NVRAM Record)
To dump the NVRAM to a file name of your choice, enter the -dumpnvram
command as follows:
-dumpnvram <hba_port_inst> [File name]
For information on the interactive version of this command, “Retrieve FW Flash &
-dv
To see the version of the iSCSI HBA driver(s) installed, enter the -dvcommand
as follows.
-dv
There is no corresponding command in the interactive menu; however, you can
use this interactive option to view the current driver version: “Install HBA Driver, All
-edchap
(Edit a CHAP Entry)
To change the value of the specified CHAP entry, enter the -edchapcommand
as follows:
-edchap <hba_port_inst> <CHAP> <Parameter> | <Parameter Alias>
<Value> [<Parameter> | <Parameter Alias> <Value> …]
SN0054621-00 E
5-11
Download from Www.Somanuals.com. All Manuals Search And Download.
5 – Non-Interactive Mode Commands
Non-interactive Commands
S
You can repeat the <Parameter>|<Parameter Alias> <Value>parameter
entry.
Table 5-2. CHAP Parameters
Parameter
CHAPName
Parameter Alias
CNAME
Value
character string
character string
on or off
CHAPSecret
CHAPBidi
CSECRET
CBIDI
Issuing this command resets the HBA. For information on the interactive version
-ei)
-f
To get information about errors and exit codes for non-interactive mode, enter the
-eicommand as follows (no parameters are required):
-ei
(Update Firmware Image—Specific HBA)
The firmware runs the tasks involved in data management, the iSCSI protocol,
and general HBA functioning. Use the -fcommand to update the firmware
image. For information on firmware file names, see Appendix E Downloadable
To update the HBA firmware from a specified file, enter the -fcommand as
follows:
-f <hba_port_inst> <file name>
Both parameters are required. The <hba_port_inst> is the HBA to update. The
<file name> is the file containing the firmware image to upload to the HBA. Be
sure to use full path names. Issuing this command resets the HBA.
For information on the interactive version of this command, see “Update Firmware
-fa
(Update Firmware Image—All HBAs)
To update the firmware for all HBAs for which the image is appropriate, enter the
-facommand as follows:
5-12
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
5 – Non-Interactive Mode Commands
Non-interactive Commands
A
-fa <Filename>
For example if the image is for a QLA4010, all QLA4010s are updated, and no
other HBAs. (Newer images may be appropriate for both QLA405x and QLA406x
type HBAs.) Issuing this command resets all updated HBAs.
For information on the interactive version of this command, see “Update Firmware
-g
(Display General System Information)
To view general system information, enter the -gcommand as follows:
-g
SANsurfer iSCSI HBA CLI shows the following:
Host name
Host version
Host type
User type
For information on the interactive version of this command, see “Display General
-gcr
(Retrieve FW Crash Record)
To get crash record information for the specified HBA port, enter the -gcr
command as follows:
-gcr <hba_port_inst> <Crash Output File>
For information on the interactive version of this command, see “Retrieve FW
-h
(Help)
To view the SANsurfer iSCSI HBA CLI help file, enter the -hcommand as follows:
-h
For convenience, you can send the output to a file for easier viewing or printing as
follows:
Iscli –h >file.txt
For information on the interactive version of this command, see “Help (CLI Option
SN0054621-00 E
5-13
Download from Www.Somanuals.com. All Manuals Search And Download.
5 – Non-Interactive Mode Commands
Non-interactive Commands
S
-i
(List All QLogic iSCSI HBA Ports Detected)
Use the -icommand to view a list of all detected HBA port instances (“ports”) in
the system. Each port instance (hba_port_inst) is identified by its number.
To view general HBA information, enter the -icommand as follows:
-i [hba_port_inst]
When you use hba_port_inst, information for only that HBA port instance is
shown. When you do not use hba_port_inst, information for all ports in the
system is shown.
The following HBA (port) information is shown:
Item number (order in which ports were detected)
HBA number, that is, the number of this HBA in the detection process
HBA port number (0 or 1) for this HBA
Port instance number in the system (two-port HBAs appear twice)
Port Instance on the HBA
HBA model number (for example, QLA4010)
HBA serial number (for example, TFC0105C51704)
Firmware version (for example, 3.0.1.45)
Connection medium
IP address (IP address of the HBA port instance)
iSCSI name (HBA port iSCSI name; the QLogic default name or one you
assign)
Alias (HBA port instance iSCSI alias name that you assign)
Figure 5-1 shows how to read the display.
HBA 0 (First HBA
detected in system)
HBA Port Instance 0
(First detected in system)
0. HBA: 0 Port: 0 HBA Port Instance: 0 HBA Model: QLA4050C
Item 0
Port 0 on this HBA
HBA Model Number
Figure 5-1 HBA Port Information
5-14
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
5 – Non-Interactive Mode Commands
Non-interactive Commands
A
The following shows an example of how the HBA port information might appear:
0.
HBA 0 Port: 0 HBA Port Instance: 0 HBA Model: QLA4050C
HBA Serial Number: FS20525B03135
IP Address: 192.168.3.7
FW Version: 2.2.4.45 Type: Copper
Alias:
iSCSI name: iqn.2000-04.com.qlogic.fs10506a02810.1
1.
2.
3.
HBA 1 Port: 0 HBA Port Instance: 1 HBA Model: QLA4062C
HBA Serial Number: AS40637A04673
IP Address: 192.168.3.22
FW Version: 3.0.1.18 Type: Copper
Alias:
iSCSI name: iqn.2000-04.com.qlogic.as10506a02810.1
HBA 1 Port: 1 HBA Port Instance: 2 HBA Model: QLA4062C
HBA Serial Number: AS40637A04673
IP Address: 192.168.3.38
FW Version: 3.0.1.18 Type: Copper
Alias:
iSCSI name: iqn.2000-04.com.qlogic.as10506a02810.1
HBA 2 Port: 0 HBA Port Instance: 3 HBA Model: QLA4010
HBA Serial Number: FS20407B03135
IP Address: 192.168.3.72
FW Version: 3.0.1.17 Type: Copper
Alias:
iSCSI name: iqn.1991-05.com.microsoft.steinway.qlogic.org
For information on the interactive version of this command, see “List All QLogic
-import
(Import HBA Configuration)
-import <hba_no_target> <hba_no_Source> [A] [F N I T C B] <File
Name>
Where:
<hba_port_inst> = The specific HBA to which the data is written
<hba_port_inst_ = The file with the HBA configuration you want.
source>
A = Configure all imported parameters (F, N, I, T, C, B).
F = Configure the firmware.
N = Configure the network parameters.
SN0054621-00 E
5-15
Download from Www.Somanuals.com. All Manuals Search And Download.
5 – Non-Interactive Mode Commands
Non-interactive Commands
S
I = Configure the iSCSI name.
T = Configure the targets.
C = Configure the CHAP table.
B = Configure the boot parameters. (only valid when T[tar-
gets] parameter is also specified).
For information on the interactive version of this command, see “Import HBA
-ipdhcp
(Configure IP Settings)
To set the HBA to get its IP address, subnet mask, and gateway from the DHCP
server, enter the -ipdhcpcommand as follows:
-ipdhcp <hba_port_inst> [-option]
If the HBA port had prior values set manually, the DHCP values replace them.
Where [option]includes:
-DISN4 = Disable IPv4 network
-IPV4DHCP = Set DHCP ON
-IP = Set IP Address
-IPNM = Set IP Netmask
-IPGW = Set IP Gateway
-DISN6 = Disable IPv6 Network Setup
-IPLLA = Set Local link Address Automatically
-IPLL = Set Local link Address Manually
-IPRA = Set IPR0 and IPR1 Automatically
-IPR0 = Set Routable Address 0 Manually
-IPR1 = Set Routable Address 1 Manually
-IPRAA = Set Router Address Automatically
-IPRR = Set Router Address Manually
For information on the interactive version of this command, see “Configure IP
-isns
(Configure iSNS Settings)
To configure the iSNS settings for QLA4010 and QLA405x, enter the -isns
command as follows:
5-16
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
5 – Non-Interactive Mode Commands
Non-interactive Commands
A
-isns <hba_port_inst> [iSNS IP Address] [iSNSPORT <port_number>]
If you do not specify the [iSNS IP Address]parameter, the command disables
the iSNS client on the specified HBA port.
Issuing this command resets the HBA.
For information on the interactive version of this command, see “iSNS Settings
-isns6
(iSNS Settings)
To configure the iSNS settings for IPv6 (QLE406x and newer), enter the -isns6
command as follows:
-isns <hba_port_inst> [iSNS IPv6-or-IPv4 Address] [-iSNSPORT
<port_number>]
If you do not specify the [iSNS IP Address]parameter, this command
disables the iSNS client on the specified HBA port.
Issuing this command resets the HBA.
For information on the interactive version of this command, see “iSNS Settings
-l
(List LUN Information)
Use the -lcommand to view the following information about LUNs attached to
the selected target:
HBA/Target/LUN number
Vendor name
Product ID
Product revision
LUN size
You can view this information for a specific LUN or for all LUNs attached to the
selected target.
To list the LUN information, enter the -lcommand as follows:
-l <hba_port_inst> <Target ID [LUN ID]>
If you do not include the LUN IDparameter, all the LUNs on the specified target
are shown.
For information on the interactive version of this command, see “List LUN
SN0054621-00 E
5-17
Download from Www.Somanuals.com. All Manuals Search And Download.
5 – Non-Interactive Mode Commands
Non-interactive Commands
S
-lb
(Perform Loopback Test)
CAUTION!
Before doing a loopback test, ensure that the HBA does not have any
outstanding I/O operations.
To run a loopback test, enter the -lbcommand as follows:
-lb <hba_port_inst> [-STOP] [-EXTLB] [-CNT <Test Count>]
Where:
hba_port_inst = The HBA port where you do the loopback test.
–STOP = The loopback test stops if a failure occurs.
–EXTLB = Runs an external loopback test. By default, runs an internal
loopback test.
-CNT = Used with Test Count to say how many loopback tests to run.
Default is 1.
Test Count = The number of loopback tests to run. One is the default. To
run more than one test, enter a number between 2–(2^31).
For information on the interactive version of this command, see “Perform
-lc
(Configure Link Configuration)
To configure the link settings, enter the -lccommand as follows:
-lc <hba_port_inst>
The optional parameters are auto-negotiate [-AUTONEG], link speed
[-LNKSPD], and flow control [-FLOW]. With auto-negotiate on, no entries should
be provided for link speed. For a copper connection and auto-negotiate off, a link
speed of 100 or 10 must be provided. For a fiber connection, the link speed is
always 1000 Mbs. The optional parameter [-FLOW]will turn on or off flow control.
-lcd
(Display Configured Link Configuration)
To display the configured link settings, enter the -lcd command. Note that because
a system reset is required for changes in link configuration to take effect, the
settings shown here may be different than the operating link configuration.
5-18
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
5 – Non-Interactive Mode Commands
Non-interactive Commands
A
-linkchap
(Assign a CHAP Entry to a Target)
To link a CHAP entry to a target, enter the -linkchapcommand as follows:
-linkchap <hba_port_inst> <CHAP No.> <Target ID>
This command does not reset the HBA.
For information on the interactive version of this command “Assign a CHAP Entry
-lp
The IPv6 local prefix list is created based on prefix information from router
advertisements. Destination IP addresses containing these prefixes can be
reached directly, without going through an intermediate router.
To display the local prefix list, enter the -lpcommand as follows:
-lp <hba_port_inst>
There is no corresponding interactive mode option for this command.
-model
-n
To view the HBA “model(s)” (board type[s]) in the system, enter the -model
command as follows:
-model
There is no corresponding interactive mode option for this command.
(Configure iSCSI Settings)
To set to HBA iSCSI parameters for single port HBAs, enter the -ncommand as
follows:
-n <HBA No.> <Config Name|Config Alias> <Value>
[<Config Name|Config Alias> <Value> …]
After you issue this command, the HBA is reset.
You can repeat the <Config Name|Config Alias> <Value> parameter set
and their ranges of values.
Table 5-3. HBA Parameters
Configuration Name
Configuration Alias
Value
Add Firmware Options
AFWAC
AFW_AutoConnect
on or off
SN0054621-00 E
5-19
Download from Www.Somanuals.com. All Manuals Search And Download.
5 – Non-Interactive Mode Commands
Non-interactive Commands
S
Table 5-3. HBA Parameters (Continued)
Configuration Name
Configuration Alias
Value
AFW_Device_Timeout
AFW_Delayed_Ack
ExeThrottle
AFWDT
AFWDACK
ET
on or off
on or off
0–32767
0–32767
FirstBurstLen
FB
IP Options
IPARP
IP_ARP_Redirect
IP_Address
on or off
IPAD
IP address format
IP address format
IP address format
IP_Subnet_Mask
IP_Gateway
IPSM
IPGW
iSCSI Options
Force_Negotiate_Main_iSCSI_
Keys
iSCSI_Alias
IALS
IDD
on or off
on or off
on or off
on or off
on or off
on or off
on or off
on or off
iSCSI_Data_Digests
iSCSI_Discovery_Logout
iSCSI_Header_Digests
iSCSI_Immediate_Data
iSCSI_Initial_R2T
iSCSI_Snack
ID
IHD
IID
IIR2T
ISNACK
IS
iSCSI_Strict_Login
TCP Options
SLPADIS
TCPDHCP
TCPN
TCP_Auto_Discovery
TCP_DHCP
on or off
on or off
TCP_Nagle
on or off
TCPMaxWindowSize
TCP_Time_Stamp
TCPMWS
TCPTMS
1000h–FFFFh
on or off
Miscellaneous Options
5-20
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
5 – Non-Interactive Mode Commands
Non-interactive Commands
A
Table 5-3. HBA Parameters (Continued)
Configuration Name
Configuration Alias
KATO
Value
KeepAliveTO
0–65535
on or offa
0–65535
0–65535
Large_Frames
MaxBurstLen
LRGFRM
MBL
MaxOutstandingR2T
Not for QLA4010
MOR2T
a
For information on the interactive version of this command, see “Configure iSCSI
-nc
(Display Neighbor Cache)
To display the neighbor cache (IPv6 only), enter the -nccommand as follows:
-nc <hba_port_inst>
For information on the interactive version of this command, see “Display Neighbor
-netconf
(Configure IPv6 Settings)
To configure the network settings, enter the -netconfcommand as follows:
-netconf <hba_port_inst> [-IP <IP Address>] [-IPNM <Subnet Mask>]
[-IPGW <Gateway IP Address>]
Where:
IP <IP Address> = Sets the IP address of the HBA.
IPNM <Subnet Mask> = Sets the subnet mask of the HBA.
-IPGW <Gateway Address> = Sets the gateway.
-DISN4 = Disables IPv4 network setup.
-IPv4DHCP = Sets DHCP on.
Setting the IP address, subnet mask, or gateway turns off DHCP address
resolution for the IP configuration, if it is on.
For information on the interactive version of this command, see “Configure IPv6
SN0054621-00 E
5-21
Download from Www.Somanuals.com. All Manuals Search And Download.
5 – Non-Interactive Mode Commands
Non-interactive Commands
S
-netconf6
(Configure IPv6 Settings)
To manually configure the IPv6 network settings, enter the -netconf6command
as follows:
-netconf6 <hba_port_inst> [-IP <IPv6 Address>] [-IPNM <Subnet
Mask><IPv6>] [-IPGW <Gateway Address>]
Where [option]includes the following:
IP <IP Address> = Sets the IP address of the HBA.
-IPNM <Subnet = Sets the subnet mask of the HBA.
Mask>
-IPGW <Gateway = Sets the gateway.
Address>
a
-DISN4 =
Disables IPv4 network setup
b
-IPV4DHCP =
Set DHCP ON
-IP = Set IP Address
-IPNM = Set IP Netmask
-IPGW = Set IP Gateway
c
-DISN6 =
-IPLLA =
-IPLL =
Disable IPv6 Network Setup
d
Set Local link Address Automatically
d
Set Local link Address Manually
e
-IPR01A =
-IPR0 =
Set IPR0 and IPR1 Automatically
e
Set Routable Address 0 Manually
e
-IPR1 =
Set Routable Address 1 Manually
f
-IPRRA =
-IPRR =
Set Router Address Automatically
f
Set Router Address Manually
Table Footnotes
a
Mutually exclusive with the other IPv4 commands
Mutually exclusive with -IP/-IPNM/IPGW
Mutually exclusive with -IPLLA/-IPLL
b
c
d
e
f
Manual or automatic—mutually exclusive
Manual or automatic—mutually exclusive
Manual or automatic—mutually exclusive
Setting the IP address, subnet mask, or gateway turns off DHCP address
resolution for the IP configuration, if it is on. Some examples of usage follow.
5-22
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
5 – Non-Interactive Mode Commands
Non-interactive Commands
A
To set only the local link address, enter the following:
-netconf6 0 -IPLL fe80::1
To set everything automatically, enter the following:
-netconf6 0 -IPLLA -IPR01A -IPRRA
To disable the IPv4 network, enter the following:
-netconf6 0 -DISN4
To disables the IPv4 and IPv6 networks:
-netconf6 0 -DISN4 DISN6
For information on the interactive version of this command, see “Configure IPv6
-nh
(Configure iSCSI Settings)
To set the HBA level parameters for multiport HBAs, enter the -nhcommand as
follows:
-nh <hba_port_inst> <Config name | Config alias> <Value>
[<<Config name | Config alias>> <Value> …]
For information on the interactive version of this command, see “Configure iSCSI
-pa
(Add a Target)
To add persistent targets, enter the -pacommand as follows:
-pa <hba_port_inst> <IP Address> [-PORT port number] [-INAME iSCSI
Name]
If you do not specify a port number [-PORT port number], SANsurfer iSCSI
HBA CLI uses the default number 3260. If you do not specify an iSCSI name,
[-INAME iSCSI Name]SANsurfer iSCSI HBA CLI uses the default value, an
empty string.
SN0054621-00 E
5-23
Download from Www.Somanuals.com. All Manuals Search And Download.
5 – Non-Interactive Mode Commands
Non-interactive Commands
S
-pad
To view all targets for a port, enter the -padcommands as follows:
-pad <hba_port_inst>
-pb
(Bind Target)
Enter the -pbcommand to bind a target (make it persistent):
-pb <hba_port_inst> <Target ID>
-pbootcode
(Set Primary Boot Target Information)
To set the primary bootcode boot target and LUN, enter the -pbootcode
command as follows:
-pbootcode <hba_port_inst> <tgt> <lun>
This command is not active for the PPC.
For information on the interactive version of this command see “Set Primary Boot
For information on secondary boot code, see “-sbootcode (Set Secondary Boot
-pdt
To disable a target, enter the -pdtcommand as follows:
-pdt <hba_port_inst> <targetId>
-pet
To enable a target, enter the -petcommand as follows:
-pet <hba_port_inst> <targetId>
-pinfo
(Port Information)
To view port information for the specified HBA, enter the -pinfocommand as
follows:
-pinfo <hba_port_inst>
For information on the interactive version of this command see “Port Link Settings
5-24
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
5 – Non-Interactive Mode Commands
Non-interactive Commands
A
-ping
(Ping Target)
To ping the target device specified IP address, enter the -pingcommand as
follows:
-ping <hba_port_inst> <IP Address> <Ping Count> <Packet size>
<IPv6 source address>
The following provides the IPv6 source addressvalues:
0 = Do Not Care
1 = Local Link
2 = Address 0
3 = Address 1
Where:
hba_port_inst = The HBA port that sends the ping.
IP Address = The IP address to pin.
Ping Count = The number of ping packets you want (1–[2^31]).
Packet Size = The size of the ping packet 0-64kB
IPv6 Source = Origin device
Address
-ps
-pu
To view persistent targets for the HBA port, enter the -pscommand as follows:
-ps <hba_port_inst> [Target ID]
If you do not specify the [Target ID], SANsurfer iSCSI HBA CLI displays all
targets for the specified HBA port number. If you do not specify the port instance
[hba_port_inst]nor the Target ID, [Target ID], SANsurfer iSCSI HBA CLI
displays all target IDs for all HBA ports in the system.
There is no interactive command for this function.
To unbind a persistent target, enter the -pucommand as follows:
-pu <hba_port_inst> <Target ID>
SN0054621-00 E
5-25
Download from Www.Somanuals.com. All Manuals Search And Download.
5 – Non-Interactive Mode Commands
Non-interactive Commands
S
-px
To unbind all persistent targets on the HBA, enter the -pxcommand as follows:
-px <hba_port_inst>
-r
(Update ROM Image)
CAUTION!
Before attempting to update the ROM image contact QLogic Customer
Support.
Before updating the ROM image, ensure that no I/O processes are
running.
An administrator must take necessary actions to ensure changes will be
fully recognized by the operating system (reboot, flush cache, sync disk,
and so forth).
A ROM update and reset will be performed that requires that all
applications accessing impacted LUNs must be shut down.
Any impacted systems must be unmounted.
Be sure to select Save changes and reset HBA afterwards; otherwise, the
change will not take effect.
Type the following command to update the specified HBA’s ROM:
-r <hba_port_inst> <File Name>
The <hba_port_inst> parameter is the HBA instance to update. The <File Name>
parameter indicates the file containing the ROM image to upload.
For information on the interactive version of this command, see “Update ROM
-rdf
Enter the -rdfcommand to restore the specified HBA port’s firmware values to
the factory default values:
-rdf <hba_port_inst>
Issuing this command resets the HBA.
There is no interactive command for this function.
5-26
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
5 – Non-Interactive Mode Commands
Non-interactive Commands
A
-rdh
(Port Restore Factory Defaults)
NOTE:
The -rdhcommand is not supported in the QLA4010 HBA.
Type the following command to restore the specified HBA port’s settings to their
factory defaults:
-rdh <hba_port_inst> [A] [F N I T C V]
Where:
hba_port_inst = HBA port whose factory settings you want to restore.
A = Restores the factory settings for the entire HBA (firmware parame-
ters, network parameters, iSCSI name, targets, CHAP table,
NVARAM, and IPSec).
Issuing this command resets the HBA. If you use this option, no
others are necessary.
F = Restores firmware parameters to the factory default values.
Issuing this command resets the HBA.
N = Restores network parameters to the factory default values.
Issuing this command resets the HBA.
I = Restores the iSCSI name to the factory default value.
Issuing this command resets the HBA.
T = Restores the targets to the factory default values.
C = Restores the CHAP table to the factory default values.
V = Restores the NVRAM to the factory default values.
If you want to restore all areas of the HBA port, either use the Aparameter, or use
no parameter. Otherwise, specify which areas to restore. For example, the
following command restores the firmware and NVRAM to the factory defaults:
-rdh <hba_port_inst> F N
For information on the interactive version of this command, see “Port Restore
SN0054621-00 E
5-27
Download from Www.Somanuals.com. All Manuals Search And Download.
5 – Non-Interactive Mode Commands
Non-interactive Commands
S
-rwt
(Perform Read/Write Buffer Test)
CAUTION!
Before doing a read/write buffer test, make sure that the HBA does not have
any outstanding I/O operations.
The read/write buffer test writes an 8- or 16-byte pattern to the disk’s buffer and
reads the written buffer back. It is non-destructive to disk data.
To do a read/write buffer test, enter the -rwtcommand as follows:
-rwt <hba_port_inst> [-STOP] [-RWPAT n] [-CNT <Test Count>]
Where:
–STOP = Stops the test if a failure occurs.
–RWPAT n = Sets the pattern to write to the buffer, one of the follow-
ing:
n = 1 (8 bytes of 0x55h) (default)
n = 2 (8 bytes of 0x5Ah)
n = 3 (16 bytes of 0xAAh)
n = 4 (16 bytes of 0xFFh)
hba_port_inst = The HBA port tested.
-CNT = Used with Test Count to set the number of tests, with
one test as default.
Test Count = The number of tests to do, with one as default. Enter a
number between 2–(2^31) for more than one test.
To continue, press ENTER.
For information on the interactive version of this command see “Perform
-save
(Save Host Configuration)
To save the configuration (in XML) of all HBAs detected, enter the -save
command as follows:
-save <File Name>
For information on the interactive version of this command, see “Save Host
5-28
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
5 – Non-Interactive Mode Commands
Non-interactive Commands
A
-sbootcode
(Set Secondary Boot Target Information)
To set the secondary boot target and LUN, enter the -sbootcodecommand as
follows:
-sbootcode <hba_port_inst> <Boot Target> <Boot LUN>
Issuing this command saves the configuration data to an XML file portable to all
platforms supported by iSCSI. This command is not active for PPC.
For information on the interactive version of this command, see “Set Secondary
-sbootcodecid
(Set Alternative Client ID)
To set the alternative client ID (seven characters maximum), enter the
-sbootcodecidcommand as follows:
-sbootcodecid <hba_port_inst> <Alternative Client ID>
This command is not active for the Power PC (PPC).
For information on the interactive version of this command, see “Set Alternative
-sdmrc
-sreset
To return the SDM library return code, enter the -sdmrccommand as follows:
-sdmrc [Simple_Pattern]
When [simple pattern]is given, only the lines containing that string are
printed.
There is no corresponding interactive command for this function.
(Reset Statistics)
To reset statistics to zero and count from this point forward, enter the -sreset
command.
-stadd
To add a send target for discovery, enter the -staddcommand as follows:
-stadd <hba_port_inst> <ip address> [chapIndex] [<TGBCA> <value>]
Where <value>can be onor off; oncauses the send target login to require
bi-directional CHAP.
SN0054621-00 E
5-29
Download from Www.Somanuals.com. All Manuals Search And Download.
5 – Non-Interactive Mode Commands
Non-interactive Commands
S
-stat
(Display Port Statistics)
To view the port statistics for the specified HBA, enter the -statcommand as
follows:
-stat <hba_port_inst>
For a list of the statistics that are displayed and information on the interactive
version of this command, see “Display Port Statistics (CLI Option -stat)” on
-stathba
To displays HBA level statistics, enter the -stathbacommand as follows:
-stathba <hba_port_inst>
-stdsp
-strd
To view the send targets, enter the -stdspcommand as follows:
-stdsp <hba_port_inst>
To execute a rediscovery of targets for the specified send target, enter the -strd
command as follows:
-strd <hba_port_inst> <target_instance>
To obtain the target instance, use the -dtdspcommand.
-strem
To remove the specified send target, enter the -stremcommand as follows:
-strem <hba_port_inst> <target_instance>
To obtain the target instance, use the -dtdspcommand.
-strema
-t
To removes all send targets, enter the -stremacommand as follows:
-strema <hba_port_inst> <target_instance>
(Display Target Information)
To view target information, enter the -tcommand as follows:
5-30
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
5 – Non-Interactive Mode Commands
Non-interactive Commands
A
-t <hba_port_inst> [Target ID]
If you only specify the <hba_port_inst>parameter, SANsurfer iSCSI HBA CLI
displays target information for all targets on the specified HBA port. If you specify
the optional parameter [Target ID], SANsurfer iSCSI HBA CLI displays
information on the specified target only. This includes both persistent and dynamic
targets.
-tc
(Configure Target Parameters)
To set target parameter settings, use the -tccommand. For a list of target
parameters you can configure, enter the following:
-tc <hba_port_inst> < Target_ID > <config_name | config_alias>
<value> <config_name | config_alias> <value>
-tp
To see information stored in Flash memory about persistent targets, enter the -tp
command. If you enter only the HBA port instance number, SANsurfer iSCSI HBA
CLI returns information for all targets of that HBA port instance. If you enter the
optional Target ID, SANsurfer iSCSI HBA CLI returns information for that target
only, for example:
-tc <hba_port_inst> <Target_ID>
There is no corresponding interactive command for this function.
-ts
To see summary information about both persistent and non-persistent targets,
enter the -tscommand as follows:
-ts [hba_port_inst] [Target_ID]
There is no corresponding interactive command for this function.
-ver
(Display Program Version Information)
To view the SANsurfer iSCSI HBA CLI program version, enter the -vercommand
as follows:
SN0054621-00 E
5-31
Download from Www.Somanuals.com. All Manuals Search And Download.
5 – Non-Interactive Mode Commands
Non-interactive Commands
S
-ver
For information on the interactive version of this command “Display Program
-vpd
(Display VPD Information)
To view Vital Product Data (VPD), enter the -vpdcommand as follows:
-vpd <hba_port_inst>
(No parameters) = Displays all targets on all HBAs
[hba_port_inst] =Displays info for all targets on HBA
[Target ID] =Displays info for that target only.
Available VPD information varies by HBA manufacturer. For information on the
interactive version of this command, see “Display VPD Information (CLI Option
-z
To export all useful data to file for use by QLogic Technical Support, enter the -z
command.
5-32
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
A Port- and HBA-level
Parameters
The tables in this appendix list the following types of SANsurfer iSCSI HBA CLI
parameters:
Port-level Parameters
parameters, both configurable and non-configurable (read-only), use the -c
option in non-interactive mode. To edit configurable parameters, use the -noption
in non-interactive mode.
NOTE:
The parameters in this table are sorted alphabetically for ease of use.
Table A-1. Port Settings
Parameter
Value
Alias
Description
AFW_AutoConnect
on, off
AFWC
When on, the HBA will not try to autoconnect to
the configured targets at boot time. Instead, the
host must issue Set Device Database Entry
commands (0063h) to establish connections to
targets.
AFW_Delayed_Ack
on, off
AFDACK
AFWDT
Determines what occurs when the HBA receives
a Data-In PDU with the Final bit set and no sta-
tus reported. When on, the HBA sends a TCP
acknowledgment immediately (this is the default
value). When this parameter is off, the HBA
delays the acknowledgment and waits for more
data.
AFW_Device_Timeout
SN0054621-00 E
on, off
When on, the HBA firmware ignores the IOCB
command timeout values specified by the host.
A-1
Download from Www.Somanuals.com. All Manuals Search And Download.
A – Port- and HBA-level Parameters
Port-level Parameters
S
Table A-1. Port Settings (Continued)
Parameter
Value
Alias
Description
on, off
AFWSTM
When enabled, the firmware will serialize all
Immediate task management function requests
(SCSI) such that only one Immediate task man-
agement command is outstanding to the target
at a time.
AFW_Serlz_Task_Mngmt
Default_IPv6_Router
DefaultTime2Retaina
IPv6
address
IPRR
IPv6 address format
0–65535 n/a
seconds
This parameter indicates the maximum logout
time (in seconds) the HBA uses when negotiat-
ing with a target device during login.
DefaultTime2Waita
Enable_4022IPv4
0–65535 n/a
seconds
This parameter indicates the minimum logout
time (in seconds) the HBA uses when negotiat-
ing with a target device during login.
on, off
E4022IPV4
Enables use of IPv4 on a 4022 board (applies to
405x and 406x HBAs).
Enable_IPv4
Enable_IPv6
ExeThrottle
on, off
on, off
EIPV4
EIPV6
Enables use of IPv4
Enables use of IPv6
0–32767 ET
Specifies the execution throttle value. The exe-
cution throttle is used by the firmware to limit the
number of concurrently executing commands.
FirstBurstLen
0–3267
units
FB
Indicates the maximum length for unsolicited
data. The HBA uses this information when nego-
tiating with a target device during login. This
parameter indicates how many units
(512 bytes/unit) of unsolicited data the HBA can
send/receive. A value of 0 indicates unlimited
data units.
Force_Negotiate_Main_
iSCSI_Keys
on, off
on, off
FNMIK
n/a
405x and 406x only. iSCSI keys (defined in
iSCSI spec) that targets are forced to negotiate.
FW_Accept_AENa
When on and the HBA is a target, generates an
asynchronous target device database change
when a new connection is accepted.
FW_Access_Controla
on, off
n/a
When on, the HBA will not enter iSCSI full- fea-
ture mode with an initiator until the target driver
authorizes the initiator.
A-2
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
A – Port- and HBA-level Parameters
Port-level Parameters
A
Table A-1. Port Settings (Continued)
Parameter
Value
Alias
Description
FW_Fast_Postinga
on, off
n/a
When on, allows posting SCSI command com-
pletions for multiple SCSI commands during a
single system interrupt.
FW_Initiator_Modea
FW_Markera
on, off
on, off
n/a
n/a
When on, the HBA is in initiator mode.
When on does not require a marker IOCB to
resume IOCB processing after a task manage-
ment mailbox command. When off, the HBA
rejects any IOCB for a target device affected by
a task management command until the driver
issues a marker IOCB to synchronize the SCSI
request queue between the HBA and the driver.
FW_Sense_Buffer_
Desca
on, off
on, off
n/a
When on, the HBA expects the last data seg-
ment descriptor of the data descriptor list associ-
ated with a Command Type 3 IOCB to be a
descriptor of a sense buffer.
When off, the HBA passes any sense data from
the target in a status IOCB.
FW_ZIO_Enable_Mode
ZIOE
Enables Zero Interrupt Operation (ZIO) mode.
When on, the firmware minimizes the number of
interrupts it generates to the host driver while it
continues to post completions to the queue.
When the ZIO count threshold is reached, the
firmware interrupts the host driver to notify it that
the queue must be drained. When an I/O com-
pletes before the ZIO count threshold, the host
driver is interrupted so it can drain all the I/O
completions from the queue.
IP_Address
IPv4
IPAD
Target IP address.
address
IP_ARP_Redirect
on, off
IPARP
When on, MAC addresses are discovered and
bound to IP addresses for hosts to which the
HBA wants to talk.
IP_Fragmentationa
on, off
n/a
When on, the HBA cannot fragment IP data-
grams. When this parameter is off, the HBA
fragments IP datagrams as necessary.
IP_Gateway
IPv4
address
IPGW
IPSM
IP address of the gateway available to the HBA.
IP_Subnet_Mask
IPv4
HBA subnet mask xxx.xxx.xxx.xxx.
address
SN0054621-00 E
A-3
Download from Www.Somanuals.com. All Manuals Search And Download.
A – Port- and HBA-level Parameters
Port-level Parameters
S
Table A-1. Port Settings (Continued)
Parameter
Value
Alias
Description
IPv4_TOS_Enable
on, off
TOS_
IPv4 type of service QLA405x and QLE406x
ENABLE
only.
IPv4_TOS
IPv4_TTL
0–255
IPV4TOS
Controls the value of the type of service (TOS)
field of IPv4 headers transmitted by the firmware
on iSCSI connections. The firmware uses the
value when transmitting IPv4 TCP packets on
iSCSI connections.
0–255
on, off
IPV4TTL
Time-to-Live (in hops). Each router decrements
TTL before transmitting it. Router discards the
datagram when TTL = zero.
IPv6_MCast_Listnr_
Disco_Enable
IPV6MLDEN
When enabled, the firmware supports the IPv6
Multicast Listener Discovery (MLDv1) protocol
by sending MLD Listener Report and Listener
Done messages. When disabled, the firmware
firmware does not support the MLD protocol.
IPv6_Addr_Local_Link
IPv6_Addr_Routable0
IPv6_Addr_Routable1
IPv6_DAD_Count
IPv6
address
IPLL
Contains the IPv6 link local address.
IPv6
address
IPR0
Contains the IPv6 first manually-configured
routable address.
IPv6
address
IPR1
Contains the IPv6 second manually-configured
routable address.
0–255
IPV6DAD
IPv6GNAE
Specifies the count for the IPv6 Duplicate
Address Detection (DAD) process.
IPv6_Gratuitious_Neighbor on, off
_Ad_Enable
When enabled, the firmware issues a series of
gratuitous neighbor advertisement messages for
its IP during initialization, when a valid IP
address has been configured.
0–255b
IPv6_Hop_Limit
IPV6HL
Specifies the IPv6 hop limit value to be used in
IPv6 TCP packets transmitted from the firmware
on iSCSI connections. Receiving an IPv6 router
advertisement with a nonzero value in the cur-
rent hop field will cause this field to be overwrit-
ten with the current hop limit advertised by the
router.
A-4
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
A – Port- and HBA-level Parameters
Port-level Parameters
A
Table A-1. Port Settings (Continued)
Parameter
Value
Alias
Description
IPv6_Nagle
on, off
TCPV6ND
When enabled, the firmware uses the Nagle
algorithm. When disabled, the firmware disables
the Nagle algorithm. (For a description of the
Nagle algorithm, see RFC 896—Congestion
Control in IP/TCP Internetworks.)
IPv6_ND_Reachable_
Timer
0–42949 IPV6NDRT
67295b
Specifies the time (in milliseconds) that a node
assumes that the neighbor is reachable after
confirmation. The configured value will be over-
written if an updated value is received in a router
advertisement.
IPv6_ND_Retransmit_
Timer
0–42949 IPV6NDRET
67295b
Specifies the time (in milliseconds) between
retransmitted neighbor solicitation messages.
The configured value will be overwritten if an
updated value is received in a router advertise-
ment.
IPv6_ND_Stale_Timeout 0–42949 IPV6STO
67295b
Specifies the time (in milliseconds) after which a
stale IPv6 neighbor cache entry is discarded.
IPv6_Port
0–65535 IPV6PORT
Specifies the default iSCSI target TCP port num-
ber for IPv6 connections.
IPv6_Redirect_Enable
on, off
PV6RDE
When enabled and neighbor advertisements are
received, the connection table is examined and
updated if any active connections match the IP
address on the neighbor advertisement. This
action is required for failover and redirect. A
MAC address changed asynchronous event
(801Bh) is issued. When disabled, the NCB
table is not modified. No asynchronous event is
issued.
IPv6_TCP_Time_Stamp
on, off
TCPV6TST
When this bit is set, the firmware negotiates to
use time stamps in TCP headers. When this bit
is cleared, the firmware does not use time
stamps in TCP headers.
SN0054621-00 E
A-5
Download from Www.Somanuals.com. All Manuals Search And Download.
A – Port- and HBA-level Parameters
Port-level Parameters
S
Table A-1. Port Settings (Continued)
Parameter
Value
Alias
Description
IPv6_TCP_Timer_Scale
0–7
TCPV6TS
Each TCP timer in the firmware is referenced to
a local timer and is defined as a number of local
timer ticks. The TCP Timer Scale bits are a
scale factor that adjusts the time interval
between timer ticks on a per connection basis.
The scale factor allows for faster time-outs for
connections running on a very small network,
versus connections running on a very large net-
work. The default value for this field is 3h.
IPv6_TCP_Window
Scale
0–14
IPV6TCPWS
IPV6TC
Specifies the TCP window scale factor to be
negotiated on IPv6 connections. This field is
similar to the IPv4 field, but applies to IPv6 con-
nections.
IPv6_Traffic_Class
0–255
Specifies the IPv6 traffic class value to be used
in IPv6 TCP packets transmitted from the firm-
ware on iSCSI connections.
IPv6_VLAN_Enable
IPv6_VLAN_ID
on, off
IPV6VLANEN When on, VLAN filtering is enabled for the HBA
(IPv6 traffic only).
0–4095
IP_V6VLANID When the IPv6_VLAN_Enable parameter is on,
this 12-bit ID (appended to inbound Ethernet
frames) must match the ID configured for that
interface. (IPv6 traffic only).
IPv6_VLAN_User_
Priority
0–7
IPV6VLANUP When the IPv6_VLAN_Enable parameter is on,
this 16-bit field is appended to outbound Ether-
net frames for the TCP connection. (IPv6 traffic
only).
iSCSI_Alias
string
IALS
n/a
Target iSCSI alias name.
iSCSI_BIDI_CHAP_
Autha
on, off
When on, the (initiator) HBA sends a CHAP
challenge to any target that has sent a CHAP
challenge to the HBA. This bit is ignored if the
iSCSI_CHAP_Auth parameter is off.
iSCSI_CHAP_Autha
iSCSI_Data_Digests
on, off
on, off
n/a
When on, the HBA Dos authentication (during
the security stage of login).
IDD
When on, iSCSi data with CRC protection can
be transmitted. In addition, incoming iSCSI data
is validated and CRC protection is removed.
A-6
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
A – Port- and HBA-level Parameters
Port-level Parameters
A
Table A-1. Port Settings (Continued)
Parameter
Value
Alias
Description
iSCSI_Data_PDU_In_
Ordera
on, off
n/a
n/a
ID
When on, the system driver reports the DataP-
DUInOrder value negotiated during login to the
HBA firmware.
iSCSI_Data_Seq_In_
Ordera
on, of
When on, the system driver reports the DataSe-
quenceInOrder value negotiated during login to
the HBA firmware.
iSCSI_Discovery_Logout on, off
When on, the HBA initiates an iSCSI logout on a
discovery session when discovery is complete
(before closing the connection). When off, the
HBA closes the TCP connection when discovery
is complete.
iSCSI_Error_Recovery_
Levela
on, off
on, off
n/a
When on, the HBA supports iSCSI error recov-
ery level 0. At this level, the HBA closes a con-
nection if it detects any errors.
iSCSI_Header_Digests
iSCSI_Immediate_Data
iSCSI_Initial_R2T
IHD
When on, iSCSi headers with CRC protection
can be transmitted. In addition, incoming iSCSI
headers are validated and CRC protection is
removed.
on, off
on, off
IID
When on, the HBA firmware negotiates (during
login phase) for Immediate Data=yes. When off,
immediate data is disabled and the firmware
negotiates for ImmediateData=no.
IIR2T
When on, the HBA negotiates (during login) for
InitialR2T=yes. When off, initial R2T is disabled
and the HBA negotiates for InitialR2T=no.
iSCSI_Send_Markersa
iSCSI_Snack
on, off
on, off
n/a
Not supported.
ISNACK
When on and the FW_Initiator_Mode parameter
is on, the HBA firmware sends SNACK requests
to the target when it detects missing PDUs.
When off and the FW_Initiator_Mode parameter
is on, the firmware aborts the command and/or
closes the connection when missing PDUs are
detected.
iSCSI_Strict_Login
on, off
IS
When on, the HBA adheres to the iSCSI login
rules, and therefore cannot operate with targets
that do not conform to these rules. When off, the
iSCSI login rules are relaxed, and the HBA can
operate with targets that do not conform to these
rules.
SN0054621-00 E
A-7
Download from Www.Somanuals.com. All Manuals Search And Download.
A – Port- and HBA-level Parameters
Port-level Parameters
S
Table A-1. Port Settings (Continued)
Value Alias Description
Parameter
KeepAliveTO
0–65535 KATO
seconds
This parameter indicates the time interval (in
seconds) between connection keep-alive pings.
When a connection is idle for the connection
keep-alive timeout interval, the HBA sends an
NOP ping to the other device (target) that is part
of the connection. When the (target) device
responds to the ping, the connection remains
open. If the (target) device fails to respond, the
HBA closes the connection and informs the
driver that the connection has gone down. The
maximum keep-alive time is 18 hours.
Large_Framesa
on, off
LRGFRM
(Not for QLA4010s) Defines the maximum
Ethernet frame length. Onsets for Jumbo (9kB
max) frames. Offsets frame length to 1.5 KB.
Determines when to fragment IP datagrams;
larger frames are discarded.
LDROUTER_AUTO
on, off
on, off
LDRA
Local default router. Gets router address auto-
matically.
LOC_LINK_AUTO
MaxBurstLen
LOCLA
Local link auto.
0–32767 MBL
unitsa
Tells max length for data sequences the HBA
uses when negotiating with a target device dur-
ing login. Tells how many 512 byte units the
HBA can send/receive. 0 means unlimited data
units.
MaxOutstandingR2T
1–
65535
MOR2T
Tells maximum number of outstanding R2Ts the
HBA uses when negotiating during login. Tells
how many R2Ts can be outstanding on a SCSI
task.
MaxRxDataSegmentLena
Porta
0–
65535
n/a
n/a
Tells maximum data segment size (in 512-byte
units) that the HBA can receive in one PDU.
0–
65535
Gives the port number the HBA (as target) lis-
tens to for iSCSI connections. Ignored when the
HBA is an initiator only. Default port = 3260.
ROUTABLE_AUTO
on, off
RAUTO
When on, the firmware will auto-configure
routable addresses from the default router (if
one is available)
A-8
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
A – Port- and HBA-level Parameters
Port-level Parameters
A
Table A-1. Port Settings (Continued)
Value Alias
Parameter
Description
Task_Management_
Timeout
0–
65535
TMTO
Timeout value for various firmware operations.
For example, timeout value is used for PDUs
created and transmitted that are not related to
IOCB and Task Management commands.
TCP_DHCP
on, off
TCPDHCP
When on, the HBA uses DHCP to get its IP
address, gateway IP address, and subnet mask.
TCP_Nagle
on, off
on, off
TCPN
When on, uses Nagle algorithm.
TCP_Time_Stamp
TCPTMS
When on, puts a timestamp in every transmitted
TCP segment. Receiver ACKs with timestamp
so transmitter can calculate RTT and retrans-
missions. When off, RTT calculated on one out-
standing segment at a time.
TCP_Timer_Scalea
—
n/a
Each TCP timer is a number of local timer ticks.
This is a scale factor that adjusts the interval
between timer ticks on each connection allowing
faster timeouts on small networks.
TCP_Window_Scale
VLAN_Enable
0–14
WINSCALE
VLAN
TCP window scale.
on, off
When on, VLAN filtering is enabled for the HBA
(IPv4 traffic only).
VLAN_ID
0–4095
0–7
VLANID
When the VLAN_Enable parameter is on, this
12-bit ID (appended to inbound Ethernet
frames) must match the ID configured for that
interface. (IPv4 traffic only).
VLAN_User_Priority
VLANUPRIOR When the VLAN_Enable parameter is on, this
16-bit field is appended to outbound Ethernet
frames for the TCP connection. (IPv4 traffic
only).
ZIO
2–16
ZIO
Number of completions the firmware posts to the
completion queue before interrupting the host
driver to say there are items in the queue. Valid
only when FW_ZIO_Enable_Mode is on.
Table Footnotes
a
Read-only parameter (alias is not applicable—”n/a”)
Router may override this parameter
b
SN0054621-00 E
A-9
Download from Www.Somanuals.com. All Manuals Search And Download.
A – Port- and HBA-level Parameters
HBA-level Parameters
S
HBA-level Parameters
both configurable and non-configurable (read-only), use the -choption in
non-interactive mode. To edit configurable parameters, use the -nhoption in
non-interactive mode.
NOTE:
The parameters in this table are sorted alphabetically for ease of use.
Table A-2. HBA Settings
Parameter
Value
Alias
Description
HBA_Alias
Character string
HBAALIAS
HBA alias name. Symbolic name
you assign to the HBA for identifi-
cation purposes.
HBA_Default_Fragment_ 40 to 600 (units are
HBADFRT
For QLE406x HBAs only. Default
value for the IP Fragment Reas-
sembly Timeout.
Reass_Timeout
1/10 secs)
HBA_Delayed_ACK
on or off
HBADELACK For QLE406x HBAs only. Deter-
mines what occurs when the HBA
receives a Data-In PDU with the
final bit set and no status reported.
When on, the HBA immediately
sends a TCP acknowledgment
(this is the default value). When
this parameter is off, the HBA
delays the acknowledgment and
waits for more data.
HBA_Reserved_TCP_
Config
(Request assistance
from QLogic Support)
HBARTCPC
For QLE406x HBAs only. A
parameter with control bits for vari-
ous TCP algorithms in the firm-
ware. Do not modify without
instruction of valid configuration
values provided by QLogic.
HBA_TCP_MAX_
Window_Size
4096 to 65535
HBATCPMWS The maximum TCP Receive Win-
dow size in bytes.
A-10
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
B HBA Statistics
NOTE:
The parameters in this table are sorted alphabetically for ease of use.
Table B-1. HBA Statistics
Statistic Abbreviation
Meaning
ECCErrorCorrectionCount
IPDatagramReassemblyCount
IPFragment ReassemblyTimeout
IPInvalidAddrErrorCount
IPRxBytesCount
ECC (error-correction count)
IP datagram reassembly count
IP fragment reassembly timeout
IP invalid address error count
IP received byte count
IPRxFragmentOutOfOrderCount
IPRxFragmentOverlapCount
IPRxFragmentsCount
IP received fragment out-of-order count
IP received fragment overlap count
IP received fragment count
IPRxPacketErrorCount
IPRxPacketsCount
IP received packet error count
IP received packet count
IPTxBytesCount
IP transmitted byte count
IPTxFragmentsCount
IP transmitted fragment count
IP transmitted packet count
IPv6 datagram reassembly
IPTxPacketsCount
IPv6DatagramReassembly
IPv6DatagramreassemblyTO
IPv6ErrorPacketCount
IPv6FragRxOutOfOrderCount
IPv6 datagram reassembly time-out
IPv6 error packet count
IPv6 fragments received out-of-order count
SN0054621-00 E
B-1
Download from Www.Somanuals.com. All Manuals Search And Download.
B – HBA Statistics
S
Table B-1. HBA Statistics (Continued)
Statistic Abbreviation
Meaning
IPv6FragRxOverlapCount
IPv6InvalidAddressError
IPv6RxByteCount
IPv6 fragment received overlap count
IPv6invalid address errors
IPv6 received byte count
IPv6RxFragmentCount
IPv6RxPacketsCount
IPv6TxByteCount
IP v6 received fragments count
IPv6 received packets count
IPv6 transmitted byte count
IPv6 transmitted fragment count
iSCSI I/Os completed count
iSCSI data digest error count
iSCSI format error count
IPv6TxFragmentCount
iSCSICompleteIOsCount
iSCSIDataDigestErrorCount
iSCSIFormatErrorCount
iSCSIHeaderDigestCount
iSCSIRxBytesCount
iSCSI header digest error count
iSCSI data bytes received count
iSCSI PDU received count
iSCSI sequence error count
iSCSI data bytes transmitted count
iSCSI PDU transmitted count
iSCSI unexpected I/O received count
MAC CRC error count
iSCSIRxPDUCount
iSCSISeqErrorCount
iSCSITxBytesCount
iSCSITxPDUCount
iSCSIUnexpectedIORxCount
MACCRCErrorCount
MACEncodingErrorCount
MACRxBroadcast
MAC encoding error count
MAC received broadcast
MACRxBytesCount
MAC received byte count
MACRxCarrierSenseError
MACRxControlFrames
MACRxDribble
MAC received carrier sense errors
MAC received control frames
MAC received dribble
MACRxFrameLengthError
MACRxFramesCount
MACRxFramesDiscarded
MAC received frame length errors
MAC received frame count
MAC received discarded frames
B-2
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
B – HBA Statistics
A
Table B-1. HBA Statistics (Continued)
Statistic Abbreviation Meaning
MACRxFramesDropped
MACRxJabber
MAC received dropped frames
MAC received jabber
MACRxLengthErrorCountLarge
MACRxLengthErrorCountSmall
MACRxMulticast
MAC received large length error count
MAC received small length error count
MAC received multicast
MACRxPauseFrames
MACRxUnknownControlFrames
MACTxAborts
MAC received pause frames
MAC received unknown control frames
MAC transmitted aborts
MACTxBroadcast
MAC transmitted broadcast
MACTxBytesCount
MAC transmitted byte count
MACTxCollisions
MAC transmitted collisions
MACTxControlFrames
MACTxDeferrals
MAC transmitted control frames
MAC transmitted deferrals
MACTxExcessDeferrals
MACTxFramesCount
MACTxFramesDropped
MACTxJumboFrames
MACTxLateCollisions
MACTxMulticast
MAC transmitted excess deferrals
MAC transmitted frame count
MAC transmitted dropped frames
MAC transmitted jumbo frames
MAC transmitted late collisions
MAC transmitted multicast
MACTxMultipleCollisions
MACTxPauseFrames
MACTxSingleCollisions
TCPDuplicateACKRetrans
TCPRetransTimerExpiredCount
TCPRxBytesCount
MAC transmitted multiple collisions
MAC transmitted pause frames
MAC transmitted single collisions
TCP Duplicate ACK retransmit
TCP re-transmit timer expired count
TCP received byte count
TCPRxDelayedACKCount
TCPRxDuplicateACKCount
TCP Receive Delayed ACK count
TCP received duplicate ACK count
SN0054621-00 E
B-3
Download from Www.Somanuals.com. All Manuals Search And Download.
B – HBA Statistics
S
Table B-1. HBA Statistics (Continued)
Statistic Abbreviation Meaning
TCPRxPureACKCount
TCP received pure ACK count
TCPRxSegmentErrorCount
TCPRxSegmentOutOfOrderCount
TCPRxSegmentsCount
TCP received segment error count
TCP received segment out-of-order count
TCP transmitted segment count
TCPRxWindowProbeCount
TCPRxWindowUpdateCount
TCPTxBytesCount
TCP received window probe count
TCP received window update count
TCP transmitted byte count
TCPTxPureACKCount
TCP transmitted pure ACK count
TCP transmitted segment count
TCPTxSegmentsCount
TCPTxWindProbePersistCount
TCP transmit window probe persistent count
B-4
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
C Target Parameters
This appendix lists target parameters, both fixed and configurable.
NOTE:
The parameters in this table are sorted alphabetically for ease of use.
You can view target information with the Display Target Information option. You
can configure a target by changing specific parameters.
SN0054621-00 E
C-1
Download from Www.Somanuals.com. All Manuals Search And Download.
C – Target Parameters
S
Table C-1. Target Parameters
Parameter
Alias
Function
Value
IPv4TOS
IPV4TOS
When the DDB entry is for an 0–255
IPv6 device (the IPv6 Device
bit—Options field bit 8—is
set), this field specifies the
IPv6 TC field to be used in
the IPv6 TCP packets trans-
mitted from the firmware to
the device. When the DDB
entry is for an IPv4 device
(the IPv6 Device bit is reset),
this field specifies the value
of the TOS field to be used in
the IPv4 TCP packets
IIPv4TTL
IPV4TTL
Time-to-Live (in hops). Each 0–255
router decrements TTL
before transmitting it. Router
discards the datagram when
TTL = zero.
TGT_4022_Delayed_Ack
TGT4022DACK
Target QLA4022 delayed
acknowledgement
on/off
TGT_DDB_IPv6
TGT_DDB_IPv6
TGTDTO
Target device database IPv6 on/off
2†
TGT_DefaultTimeout
TGT_DefaultTime2Retain
TGT_DevType
Target default timeout
20*†
Target default time to retain
0*†
Target device type
TGT_DIF_Enable
TGT_ExeCount
TGTDIFFEN_IPv6
Target DIF enable
on/off
0*†
Target execution count
Target execution throttle
Target first burst length
Target forces negotiation
64†
TGT_ExeThrottle
TGT_FirstBurstLen
TGTET
256†
on/off
TGTFB
T
GT_Force_Negotiate_Main_iSCSI_
TGTFNMIK
Keys
TGT_InitiatorSessID
TGT_IPv6_Address
TGT_IPv6_Flow_Label
TGT_IPv6_iSCSI_Name
TGTISID
Target initiator session ID
Target IPv6 address
‡
IPv6
TGTFLWLBL
Target IPv6 flow label
Target IPv6 iSCSI name
‡
‡
TGTINAME_IPv6
C-2
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
C – Target Parameters
A
Table C-1. Target Parameters (Continued)
Parameter
Alias
Function
Value
TGT_IPv6_Port
TGTPORT_IPv6
Target IPv6 port
Target IPv6 source address
3260
IPv6
0-3†
TGT_IPv6_Source Addr
TGT_IPv6_Source Addr_Flg
TGTSRCADDRIPv6 Target IPv6 source address
flag
TGT_iSCSI_Name
TGTINAME
TGTKATO
Target iSCSI name
‡
30†
TGT_KeepAliveTimeout
TGT_Local_IPv6_Address
TGT_Local_TCP_Port
TGT_MaxBurstLen
Target keep-alive timeout
Target local IPv6 address
Target local TCP port
IPv6
29044*
512†
1†
TGTMB
Target maximum burst length
TGT_MaxOutstandingR2T
TGEMOR2T
Target max outstanding
ready-to-transmit
128*†
1460
0*†
TGT_MaxRxDataSegmentLen
TGT_MaxSegmentSize
Target max receive data seg-
ment length
TGTMSS
Target maximum segment
size
TGT_MaxTxDataSegmentLen
TGT_Perm_Redirect_Option
Target maximum transmit
data segment length
Target permanent redirect
option
on/off*
TGT_Port
TGTPORT
Target port
3260
IPv4*
TGT_Redirect_IPAddr
TGT_Redirect_IPAddr_State
Target redirect IP address
Target redirect IP address
state
yes/no
*
0*†
0*†
0†
TGT_RetryCount
Target retry count
Target retry delay
TGT_RetryDelay
TGT_Rx_Window_Scale
TGT_TargetID
TGTRXWINSCALE Target receive window scale
2*†
2x†
IPv4
0*†
Target ID
TGT_TargetSessID
TGT_TargetIPAddress
TGT_TargetPortalGroupID
Target session ID
TGTIPADD
Target IP address
Target portal group ID
SN0054621-00 E
C-3
Download from Www.Somanuals.com. All Manuals Search And Download.
C – Target Parameters
S
Table C-1. Target Parameters (Continued)
Alias Function
Parameter
Value
10†
TGT_TaskManagementTimeout
TGTTMS
Target task management tim-
eout
TGT_TimeStamp_Enable
Target time-stamp enable
64*
TGT_Temp_Redirect_Option
Target temporary redirect
option
on/off*
0*†
TGT_Traffic_Class
Target traffic class
2*†
TGT_Tx_Window_Scale
TGT_Type_of_Service
TGT_Window_Scale_Enable
TGTIPO_Fragmentation
Target transmit window scale
Target type-of-service
0†
TGTWINSCALEEN Target window scale enable
on/off
on*
Target IP Option fragmenta-
tion
TGTISCSIO_Bidi_CHAP_
Authentication
Target iSCSI I/O BIDI CHAP on/off*
authentication
TGTISCSIO_CHAP_Authentication
Target iSCSI I/O CHAP
authentication
on/off*
TGTISCSIO_Data_Digests
TGTIDD
TGTLDS
Target iSCSI I/O data digests on/off
TGTISCSIO_Data_PDU_In_Order
Target iSCSI I/O data
PDU-in-order
on/off*
on/off*
on/off
0*†
TGTISCSIO_Data_Sequence_In_Order
TGTISCSIO_Discovery_Logout
TGTISCSIO_Error_Recovery_Level
TGTISCSIO_Header_Digests
TGTISCSIO_Immediate_Data
TGTISCSIO_Initial_R2T
Target iSCSI I/O data
sequence-in-order
Target iSCSI I/O discovery
logout
Target iSCSI I/O error recov-
ery level
TGTIHD
TGTIID
Target ISCSI I/O header
digests
on/off
on/off
Target iSCSI I/O immediate
data
TGTIIR2T
Target iSCSI I/O initial ready on/off
to transmit
TGTISCSIO_Receive_Markers
Target iSCSI I/O receive
markers
on/off*
C-4
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
C – Target Parameters
A
Table C-1. Target Parameters (Continued)
Parameter
Alias
Function
Value
TGTISCSIO_Send_Markers
Target iSCSI I/O send mark- on/off*
ers
TGTISCSIO_Snack
TGTISCSIO_Strict_Login
TGTISCSIO_Strict_Logout
TGTO_Active
TGTISNACK
TGTIS
Target iSCSI I/O snack
on/off
on/off
Target iSCSI I/O strict login
TGTLDS
Target iSCSI I/O strict logout on/off
Target option active on/off*
Target option access granted on/off*
TGTO_Access_Granted
TGTO_Initiator_Entry
TGTO_Target Entry
TGTTCPO_Nagle
Target option initiator entry
Target option target entry
Target TCP option Nagle
on/off*
on/off*
on/off
3†
TGTTCPN
TGTTMS
TGTTCPO_Timer_Scale
Target TCP option timer
scale
TGTTCPO_Timestamp
Target TCP option timestamp on/off
Table Footnotes
TGT = target
O = option
TCP = Transmission Control Protocol
IP = Internet Protocol
* Read-only
† Typical value
‡ Varies with each implementation
SN0054621-00 E
C-5
Download from Www.Somanuals.com. All Manuals Search And Download.
C – Target Parameters
S
Notes
C-6
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
D Error Codes
This appendix provides the error codes for both CLI modes, interactive and
non-interactive.
Interactive Mode Error Codes
code.
NOTE:
The return codes in this table are sorted numerically for ease of use.
Table D-1. Interactive-Mode Error Code Descriptions
Return
Name
Description
0
CORE_STATUS_GOOD
CORE_ERR_INV
Success
100
Invalid parameter: use -hswitch to see proper
usage.
101
102
103
104
105
106
107
108
109
110
CORE_ERR_MEM_FAIL
CORE_ERR_SDM_FAIL
CORE_ERR_NO_HBA
Failed to allocate memory error.
A call to the SDM Library failed.
HBA instance specified is invalid.
Failed to open the HBA for an operation.
Failed to save the INITFW settings to the HBA.
Failure resetting the HBA.
CORE_ERR_HBAOPEN
CORE_ERR_SAVE_INITFW
CORE_ERR_HBARESET
CORE_ERR_RO_PARAM
CORE_ERR_MISSING_PARAM
CORE_ERR_FWUPD
Cannot change a read-only parameter.
A required parameter was missing.
An error occurred updating the firmware.
CORE_ERR_INVFILE
The file name entered is invalid or does not
exist.
SN0054621-00 E
D-1
Download from Www.Somanuals.com. All Manuals Search And Download.
D – Error Codes
Interactive Mode Error Codes
S
Table D-1. Interactive-Mode Error Code Descriptions (Continued)
Return
Name
Description
111
CORE_ERR_NOSPACE
No space in persistent or dynamic table for this
entry.
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
CORE_ERR_NOCOUNT
A count is required.
CORE_ERR_HBAINV
The specified HBA was invalid.
No TGT to operate on was specified.
No LUN to operate on was specified.
Operation requires a key/value pair.
Specified TGT invalid for this operation.
Error posting information to the InitFW structure.
Unknown system error.
CORE_ERR_NO_TGT
CORE_ERR_NO_LUN
CORE_ERR_NO_PAIR
CORE_ERR_TGT_INV
CORE_ERR_POSTTOIFW
CORE_ERR_UNKNOWN
CORE_ERR_NO_CHAP
No CHAP entry specified.
CORE_ERR_CHAP_SAVE_FAIL
CORE_ERR_DDB_SAVE_FAIL
CORE_ERR_GET_TGTINFO_FAIL
CORE_ERR_STATS_READ_FAILED
CORE_ERR_WRITE_FAILED
CORE_ERR_READ_DEF_IFW
CORE_ERR_GET_CRASH_REC
CORE_ERR_GET_IFW
Failed to save the CHAP entry.
Failed to save DDB.
Failed to get target information.
Failed to get statistic information.
Failed to write information.
Failed to read default firmware settings.
Failed to read crash records.
Failed to read the InitFW structure.
Invalid CHAP specified.
CORE_ERR_INV_CHAP
CORE_ERR_CHAP_TBL_FULL
CORE_ERR_NOT_SUPPORTED
CORE_ERR_READ_VPD
CORE_ERR_RUNNING_LB
CORE_ERR_CHAP_CONV
CORE_ERR_GET_STATS
CORE_ERR_IP_ADD_INV
CORE_ERR_DHCP_INV
CHAP Table is full.
Function not supported.
Could not read VPD information.
Error during Loop Back Test.
Cannot display, CHAP conversion needed.
Error getting CORE statistics from the HBA.
Address Format is invalid.
Cannot enable TCPIP/DHCP for this service.
D-2
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
D – Error Codes
Interactive Mode Error Codes
A
Table D-1. Interactive-Mode Error Code Descriptions (Continued)
Return
Name
Description
138
CORE_ERR_INITFW_INVALID
Invalid IP address in InitFW. Correct to save
changes.
139
140
141
142
CORE_ERR_SETBOOTCODE
CORE_ERR_INV_LUN
Bootcode save error.
LUN is invalid.
CORE_ERR_NO_LUN_INFO
Cannot get LUN information for this target.
CORE_ERR_NOT_SUPPORTED_BY_
FW
Operation unsupported in current firmware ver-
sion.
143
144
145
146
CORE_ERR_BOOTCODE_ENABLED
Operation not allowed with BOOTCODE is
enabled.
CORE_ERR_BOOTCODE_INVALID_
VENDORID
Vendor ID can only be 8 characters long.
CORE_ERR_BOOTCODE_INVALID_
ALTCLIENTID
Alt Client ID can only be 7 characters long.
CORE_ERR_BOOTCODE_MODE_
INVALID
Invalid Bootcode Mode.
Bootcode Mode not allowed for QLA4010.
For other HBAs with HBA DHCP off, allowed
modes are 1 and 2, with HBA DHCP on. Mode 3
is also allowed.
147
148
149
150
CORE_ERR_NO_IMP_HBAS
No HBAs in specified file to import.
Parsing error in the specified file.
Invalid source HBA provided for import.
CORE_ERR_PARSING_ERROR
CORE_ERR_INVALID_SOURCE_HBA
CORE_ERR_BOOTCODE_CHECKSUM Checksum test failed: corrupt bootcode file or
_FAILURE
problems during download.
Bootcode erased to avoid major HBA failure.
151
CORE_ERR_BOOT_TARGET
Target is a boot target & bootcode boot is
enabled.
152
153
CORE_ERR_ZIP_FILE_NOT_FOUND
Driver zip/inf file not found.
Unable to unzip driver file.
CORE_ERR_UNABLE_TO_UNZIP_
DRIVER_FILE
154
155
CORE_ERR_UNBLE_TO_GET_DRIVER Unable to get driver version from the driver file.
_VERSION_FROM_DRIVER_FILE
CORE_ERR_UNABLE_TO_GET_INFO_ Unable to get info from driver file.
FROM_DIRVER_FILE
SN0054621-00 E
D-3
Download from Www.Somanuals.com. All Manuals Search And Download.
D – Error Codes
Interactive Mode Error Codes
S
Table D-1. Interactive-Mode Error Code Descriptions (Continued)
Name Description
Return
156
CORE_ERR_SECURITY_DESCRIPTOR Security descriptor initialization failed.
_INITIALIZATION_FAILED
157
CORE_ERR_UNABLE_SET_SECURITY Unable to set security descriptor decl.
_DESCRIPTOR_DECL
158
159
160
CORE_ERR_DRIVER_UPDATE_FAILED Driver update failed.
CORE_ERR_DEVICE_NOT_FOUND
Device not found.
CORE_ERR_UNABLE_TO_BUILD_
ADAPTER_ID
Unable to build adapter ID.
161
162
CORE_ERR_OPERATION_NOT_
SUPPORTED
Operation not supported.
Failure to install driver.
CORE_ERR_FAILURE_TO_INSTALL_
DRIVERS
163
164
165
166
167
168
CORE_ERR_UNEXPECTED_FILE_TYPE Unexpected input file type.
ERR_INVALID_CFG_PARAMETER
CORE_ERR_GET_V6_CACHE
CORE_ERR_GET_ARP_TABLE
CORE_ERR_WRONG_FW_IMAGE
Invalid configuration parameter.
Retrieval of IPv6 data failed.
Retrieval of ARP table failed.
Firmware image invalid for this HBA type.
CORE_ERR_NOT_SUPPORTED_FOR_ Operation not supported by this HBA model.
HBA
169
CORE_ERR_USER_NOT_PRIVILEGED User not privileged for this operation.
_FOR_OPERATION
170
171
172
173
174
175
191
CORE_ERR_NO_APPROPRIATE_HBAS No appropriate HBAs for this firmware image.
—
Reserved—not used.
No HBAs detected.
No driver found.
CORE_ERR_NO_HBAS
CORE_ERR_NO_DRIVER_FOUND
CORE_ERR_ISNS_NOT_SUPOORTED ISNS not supported.
CORE_UNKNOWN_ERR_MSG
—
Error has no message in the catalog.
Reserved—not used.
D-4
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
D – Error Codes
Non-interactive Mode Error Codes
A
Non-interactive Mode Error Codes
associated with each.
NOTE:
The commands in this table are sorted alphabetically for ease of use.
Table D-2. Non-interactive Mode Error Codes
Command
Error Codes
-addchap
CORE_ERR_HBAINV
CORE_ERR_NO_HBA
CORE_ERR_CHAP_CONV
CORE_ERR_CHAP_TBL_FULL
CORE_ERR_EXT
CORE_ERR_CHAP_SAVE_FAIL
-b
CORE_ERR_HBAINV
CORE_ERR_NO_HBA
CORE_ERR_EXT
-binfo
CORE_ERR_HBAINV
CORE_ERR_NO_HBA
-bootcode
CORE_ERR_HBAINV
CORE_ERR_NO_HBA
CORE_ERR_INV
CORE_ERR_BOOTCODE_CHECKSUM_FAILURE
-bootcodemode
-bootcode
CORE_ERR_HBAINV
CORE_ERR_NO_HBA
CORE_ERR_INV
CORE_ERR_HBAINV
CORE_ERR_NO_HBA
CORE_ERR_INV
CORE_ERR_BOOTCODE_CHECKSUM_FAILURE
CORE_ERR_BOOTCODE_MODE_INV
CORE_ERR_SETBOOTCODE
SN0054621-00 E
D-5
Download from Www.Somanuals.com. All Manuals Search And Download.
D – Error Codes
Non-interactive Mode Error Codes
S
Table D-2. Non-interactive Mode Error Codes (Continued)
Command
Error Codes
-bootcodemode
CORE_ERR_HBAINV
CORE_ERR_NO_HBA
-c
CORE_ERR_HBAINV
CORE_ERR_NO_HBA
-chapmap
-cpbootcode
CORE_ERR_HBAINV
CORE_ERR_NO_HBA
CORE_ERR_HBAINV
CORE_ERR_NO_HBA
CORE_ERR_SETBOOTCODE
-csbootcode
-defbidi
CORE_ERR_HBAINV
CORE_ERR_NO_HBA
CORE_ERR_SETBOOTCODE
CORE_ERR_HBAINV
CORE_ERR_NO_HBA
CORE_ERR_INV
CORE_ERR_CHAP_CONV
CORE_ERR_CHAP_TBL_FULL
CORE_ERR_EXT
CORE_ERR_CHAP_SAVE_FAIL
-delchap
CORE_ERR_HBAINV
CORE_ERR_NO_HBA
CORE_ERR_INV
CORE_ERR_CHAP_CONV
CORE_ERR_EXT
CORE_ERR_CHAP_SAVE_FAIL
-df
CORE_ERR_HBAINV
CORE_ERR_NO_HBA
CORE_ERR_EXT
D-6
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
D – Error Codes
Non-interactive Mode Error Codes
A
Table D-2. Non-interactive Mode Error Codes (Continued)
Command
Error Codes
-d
CORE_ERR_ZIP_FILE_NOT_FOUND
CORE_ERR_UNABLE_TO_UNZIP_DRIVER_FILE
CORE_ERR_UNABLE_TO_GET_INFO_FROM_DIRVER_FILE
CORE_ERR_SECURITY_DESCRIPTOR_INITIALIZATION_FAILED
CORE_ERR_UNABLE_SET_SECURITY_DESCRIPTOR_DECL
CORE_ERR_DRIVER_UPDATE_FAILED
CORE_ERR_DEVICE_NOT_FOUND
CORE_ERR_UNABLE_TO_BUILD_ADAPTER_ID
CORE_ERR_OPERATION_NOT_SUPPORTED
CORE_ERR_FAILURE_TO_INSTALL_DRIVERS
CORE_ERR_UNEXPECTED_FILE_TYPE
-dspchap
CORE_ERR_HBAINV
CORE_ERR_NO_HBA
CORE_ERR_CHAP_CONV
-dumpnvram
CORE_ERR_HBAINV
CORE_ERR_NO_HBA
CORE_ERR_MISSING_PARAM
CORE_ERR_INVFILE
-dv
CORE_ERR_NO_DRIVER_FOUND
-edchap
CORE_ERR_HBAINV
CORE_ERR_NO_HBA
CORE_ERR_INV
CORE_ERR_CHAP_CONV
CORE_ERR_EXT
CORE_ERR_CHAP_SAVE_FAIL
-ei
-f
—
CORE_ERR_HBAINV
CORE_ERR_NO_HBA
CORE_ERR_FWUPD
CORE_ERR_INV
-g
—
SN0054621-00 E
D-7
Download from Www.Somanuals.com. All Manuals Search And Download.
D – Error Codes
Non-interactive Mode Error Codes
S
Table D-2. Non-interactive Mode Error Codes (Continued)
Command Error Codes
-gcr
CORE_ERR_HBAINV
CORE_ERR_NO_HBA
CORE_ERR_INV
CORE_ERR_GET_CRASH_REC
-i
CORE_ERR_HBAINV
CORE_ERR_NO_HBA
-import
CORE_ERR_HBAINV
CORE_ERR_NO_HBA
CORE_ERR_INV
CORE_ERR_INVALID_SOURCE_HBA
CORE_ERR_INVFILE
CORE_ERR_EXT
CORE_ERR_INITFW_INVALID
CORE_ERR_SAVE_INITFW
CORE_ERR_HBAOPEN
CORE_ERR_CHAP_SAVE_FAIL
CORE_ERR_DDB_SAVE_FAIL
CORE_ERR_SETBOOTCODE
-ipdhcp
-isns
CORE_ERR_HBAINV
CORE_ERR_NO_HBA
CORE_ERR_SAVE_INITFW
CORE_ERR_INITFW_INVALID
CORE_ERR_HBAINV
CORE_ERR_NO_HBA
CORE_ERR_INV
CORE_ERR_NOT_SUPPORTED
CORE_ERR_EXT
CORE_ERR_ISNS_NOT_SUPOORTED
D-8
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
D – Error Codes
Non-interactive Mode Error Codes
A
Table D-2. Non-interactive Mode Error Codes (Continued)
Command Error Codes
-isns6
CORE_ERR_HBAINV
CORE_ERR_NO_HBA
CORE_ERR_INV
CORE_ERR_NOT_SUPPORTED
CORE_ERR_EXT
CORE_ERR_ISNS_NOT_SUPOORTED
-l
CORE_ERR_HBAINV
CORE_ERR_NO_HBA
CORE_ERR_NO_TGT
CORE_ERR_EXT
CORE_ERR_INV
-lb
CORE_ERR_HBAINV
CORE_ERR_NO_HBA
CORE_ERR_INV
-linkchap
CORE_ERR_HBAINV
CORE_ERR_NO_HBA
CORE_ERR_INV
CORE_ERR_CHAP_CONV
CORE_STATUS_BAD
CORE_ERR_INV_CHAP
CORE_ERR_TGT_INV
-model
CORE_ERR_HBAINV
CORE_ERR_HBAINV
CORE_ERR_NO_HBAS
SN0054621-00 E
D-9
Download from Www.Somanuals.com. All Manuals Search And Download.
D – Error Codes
Non-interactive Mode Error Codes
S
Table D-2. Non-interactive Mode Error Codes (Continued)
Command Error Codes
-n
CORE_ERR_HBAINV
CORE_ERR_NO_HBA
CORE_ERR_NO_PAIR
CORE_ERR_POSTTOIFW
CORE_ERR_EXT
CORE_ERR_INITFW_INVALID
CORE_ERR_CHAP_SAVE_FAIL
CORE_ERR_DDB_SAVE_FAIL
CORE_ERR_HBAOPEN
CORE_ERR_HBAOPEN
CORE_ERR_SETBOOTCODE
CORE_ERR_SAVE_INITFW
CORE_ERR_INV
-netconf
CORE_ERR_HBAINV
CORE_ERR_NO_HBA
CORE_ERR_INV
CORE_ERR_INITFW_INVALID
CORE_ERR_SAVE_INITFW
-netconf6
CORE_ERR_HBAINV
CORE_ERR_NO_HBA
CORE_ERR_INV
CORE_ERR_INITFW_INVALID
CORE_ERR_SAVE_INITFW
-ping
-pa
CORE_ERR_HBAINV
CORE_ERR_NO_HBA
CORE_ERR_INV
CORE_ERR_IP_ADD_INV
CORE_ERR_HBAINV
CORE_ERR_NO_HBA
CORE_ERR_INV
CORE_ERR_EXT
D-10
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
D – Error Codes
Non-interactive Mode Error Codes
A
Table D-2. Non-interactive Mode Error Codes (Continued)
Command
Error Codes
-pbootcode
CORE_ERR_HBAINV
CORE_ERR_NO_HBA
CORE_ERR_INV
CORE_ERR_TGT_INV
CORE_ERR_NOT_SUPPORTED
CORE_ERR_SETBOOTCODE
-pb
CORE_ERR_HBAINV
CORE_ERR_NO_HBA
CORE_ERR_INV
CORE_ERR_NOSPACE
CORE_ERR_EXT
-pinfo
-ps
CORE_ERR_HBAINV
CORE_ERR_NO_HBA
CORE_ERR_EXT
CORE_ERR_HBAINV
CORE_ERR_NO_HBA
CORE_ERR_INV
CORE_ERR_TGT_INV
CORE_ERR_NOCOUNT
CORE_ERR_INV
-pu
CORE_ERR_HBAINV
CORE_ERR_NO_HBA
CORE_ERR_TGT_INV
CORE_ERR_INV
-px
-r
CORE_ERR_HBAINV
CORE_ERR_NO_HBA
CORE_ERR_HBAINV
CORE_ERR_NO_HBA
CORE_ERR_INV
SN0054621-00 E
D-11
Download from Www.Somanuals.com. All Manuals Search And Download.
D – Error Codes
Non-interactive Mode Error Codes
S
Table D-2. Non-interactive Mode Error Codes (Continued)
Command Error Codes
-rdf
CORE_ERR_HBAINV
CORE_ERR_NO_HBA
CORE_ERR_FWUPD
CORE_ERR_READ_DEF_IFW
-rdh
-rwt
CORE_ERR_HBAINV
CORE_ERR_NO_HBA
CORE_ERR_INV
CORE_ERR_SDMFAIL
CORE_ERR_NOT_SUPPORTED
CORE_ERR_HBAINV
CORE_ERR_NO_HBA
CORE_ERR_INV
-save
CORE_ERR_INV
CORE_ERR_INVFILE
-sbootcode
CORE_ERR_HBAINV
CORE_ERR_NO_HBA
CORE_ERR_INV
CORE_ERR_TGT_INV
CORE_ERR_NOT_SUPPORTED
CORE_ERR_SETBOOTCODE
-sbootcodecid
CORE_ERR_HBAINV
CORE_ERR_NO_HBA
CORE_ERR_INV
CORE_ERR_NOT_SUPPORTED
CORE_ERR_SETBOOTCODE
-sbootcodecid
-sec
CORE_ERR_INV
CORE_ERR_INVALID_CFG_PARAMETER
-stat
CORE_ERR_HBAINV
CORE_ERR_NO_HBA
CORE_ERR_GET_STATS
D-12
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
D – Error Codes
Non-interactive Mode Error Codes
A
Table D-2. Non-interactive Mode Error Codes (Continued)
Command Error Codes
-t
CORE_ERR_HBAINV
CORE_ERR_NO_HBA
CORE_ERR_INV
-ts
CORE_ERR_HBAINV
CORE_ERR_NO_HBA
CORE_ERR_INV
-ver
-vpd
CORE_ERR_HBAINV
CORE_ERR_NO_HBA
SN0054621-00 E
D-13
Download from Www.Somanuals.com. All Manuals Search And Download.
D – Error Codes
Non-interactive Mode Error Codes
S
Notes
D-14
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
E Downloadable File Names
for QLogic iSCSI HBAs.
Table E-1. File Names
File Type
HBA
File Name
Description
Boot Code
405x
BIOS for x86 and x64 processors; FCode or EFI for
Solaris—allows system boot from.
Boot Code
406x
BIOS for x86 and x64 processors; FCode or EFI for
Solaris—allows system boot from.
BIOS
405x
406x
4010
405x
406x
4010
405x
406x
405x
406x
4010
QL4022RM.bin
QL4022RM.bin
QL4010RM.bin
isp4022.fc
isp40xx.fc
isp4010-01.04.fc
qla4022.dl
qla4010.dl
ld4022.dl
BIOS
BIOS
FCode
FCode
FCode
Firmware
ROM
ROM
ROM
Contact Customer Support
Contact Customer Support
Contact Customer Support
ld4022.dl
ld4010.dl
SN0054621-00 E
E-1
Download from Www.Somanuals.com. All Manuals Search And Download.
E – Downloadable File Names
S
Notes
E-2
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
F Using Trace
Tracing can provide useful information to QLogic developers for identifying
application, HBA, and networking issues. For advanced users of SANsurfer iSCSI
HBA CLI, tracing may provide useful information about detailed steps that are
occurring for various operations.
To use trace:
1.
To identify the directory in which to place the configuration file, follow these
steps:
a.
b.
c.
Right-click the SANsurfer iSCSI HBA CLI Windows desktop icon.
Click Properties.
On the Shortcut page, click Find Target.
2.
3.
Go to the following directory:
C:\installed\pre-dvt-1.1.00.09
To activate trace, locate the iscli.cfg.txtfile and rename it to
iscli.cfg.
4.
5.
Run SANsurfer iSCSI HBA CLI.
Modify the trace variables, levels, and data as described in the following
sections.
6.
Run SANsurfer iSCSI HBA CLI again.
You can control tracing by putting an iscli.cfgfile in the location of the
SANsurfer iSCSI HBA CLI executable module or in a working directory.
SN0054621-00 E
F-1
Download from Www.Somanuals.com. All Manuals Search And Download.
F – Using Trace
S
Trace Variables
Table F-1. Trace Parameters
Variable Character String
Set Level only
True or False
True or False
True or False
True or False
True or False
True or False
True or False
True or False
True or False
True or False
True or False
True or False
True or False
True or False
True or False
True or False
—
Output buffered
Source Line and file
Console
Console Date time Prefix
Dump FW Cmp inst
Dump Mem Portal
Dump Mem node
Dump Mem chip
Dump mem params
Dump mem isns
Dump mem hbaentry
Dump mem bootcode
Dump memtargets
file
datetimeprefix
filename
archive.filename.extension
maxsize
—
—
Trace Level
You can select the iSCSI trace level by choosing a number from 0 to 1000. For
example:
iscsi.cli.trace.level = 0 to 1000
F-2
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
F – Using Trace
A
Table F-2. Trace Level Commands
Value
Trace Level
0
No trace data requested
Error level
50
100
200
300
400
500
600
700
900
Warning error
Event level
Spawn level
Trace level
Connection level
Memory level
Config level
Low level
1000 All levels
To continue, press ENTER.
Table F-3. Some More Info About Trace Levels
Trace Output
Value
iscsi.cli.clear.screen
true or false
true or false
true or false
true or false
true or false
true or false
true or false
iscsi.cli.trace.output.setlevelonly
iscsi.cli.trace.output.buffered
iscsi.cli.trace.output.src.line.and.file
iscsi.cli.trace.output.console
iscsi.cli.trace.output.console.datetimeprefix
iscsi.cli.trace.output.dump.mem.fw
iscsi.cli.trace.output.dump.mem.fw.cmp.inst
iscsi.cli.trace.output.dump.mem.portal
iscsi.cli.trace.output.dump.mem.node
iscsi.cli.trace.output.dump.mem.chip
int (hba instance)
true or false
true or false
true or false
SN0054621-00 E
F-3
Download from Www.Somanuals.com. All Manuals Search And Download.
F – Using Trace
S
Table F-3. Some More Info About Trace Levels (Continued)
Trace Output
Value
iscsi.cli.trace.output.dump.mem.params
iscsi.cli.trace.output.setlevelonly
iscsi.cli.trace.output.dump.mem.isns
iscsi.cli.trace.output.dump.mem.hbaentry
iscsi.cli.trace.output.dump.mem.bootcode
iscsi.cli.trace.output.dump.mem.targets
iscsi.cli.trace.output.file
true or false
true or false
true or false
true or false
true or false
true or false
true or false
true or false
string
iscsi.cli.trace.output.file.datetimeprefix
iscsi.cli.trace.output.file.filename
iscsi.cli.trace.output.file.archive.filename.extension string
0a–2147000000
0–1000
iscsi.cli.trace.output.file.maxsize
iscsi.sdm.trace.level
a
0=unlimited
To continue, press ENTER.
Trace Data
:
Table F-4. Trace Data
Amount
Data Level
0
No trace data requested
Error level
50
100
200
400
1000
Warning error
Event level
Trace level
All levels
To continue, press ENTER.
F-4
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
Glossary
adapter
See HBA.
up and running. There are also secondary
functions that can be performed by the
boot code, including managing the setup
for the HBA and initializing and testing the
HBA's ISP.
AL_PA
Arbitrated Loop_Physical Address. A
low-level address on the FC loop.
boot device
arbitrated loop
The device, usually a the hard disk, that
contains the operating system the BIOS
uses to boot from when the computer is
started.
A circular (ring) topology (versus
point-to-point) where two or more ports
can be interconnected, but only two ports
can communicate at a time. All communi-
cation passes through all ports connected
to the loop.
cache
A temporary high-speed storage (memory)
area where recently used or frequently
accessed data is stored for rapid access,
thus increasing the efficiency of processor
operations.
BIOS
Basic input output system (typically in
Flash PROM). The program (or utility) that
serves as an interface between the
hardware and the operating system and
allows booting from the HBA at startup.
Cache contents duplicate recently-used
values stored on disk or elsewhere. Cache
is quick to access relative to the original
data which either takes more time due to
slow disc-access time, or is slow to
boot code
The program that initializes a system or an
HBA. Boot code is the first program to run
when a system or a devices within a
system, such as an HBAs. FCode, BIOS,
and EFI (enhanced firmware interface) are
all forms of boot code for specific
compute. Once data is stored in the cache,
future use can be made by accessing the
cached copy rather than re-finding or
recomputing the original data, so that the
average access time is lower.
L1 cache—Primary (smallest) cache
hardware/operating system environments.
on the same chip as the processor.
Boot code for QLogic FC HBAs is required
if the computer system is booting from a
storage device (disk drive) attached to the
HBA. The primary function of the boot
code is communication with the external
boot device before the operating system is
L2 cache—Secondary (larger) cache.
Either on the processor chip or
external to the processor.
SN0054621-00 E
Glossary-1
Download from Www.Somanuals.com. All Manuals Search And Download.
SANsurfer iSCSI HBA CLI User’s Guide
Command Line Interface for QLogic iSCSI Host Bus Adapters
S
CNA
Converged network adapters support both
Port Driver. The middle driver level,
which handles aspects of the operation
specific to the port type; for example,
there is a port driver for SCSI.
data networking (TCP/IP) and storage
networking (FC) traffic on a single I/O
adapter using two new technologies:
Enhanced Ethernet and Fibre Channel
over Ethernet (FCoE).
In Red Hat/SUSE Linux, the driver layers
include:
SCSI Upper Layer. This is the device
management layer. It handles
CoS
device-dependent tasks for devices,
such as disks and tapes.
Class of Service (CoS) is a 3 bit field within
a layer two Ethernet frame header when
using IEEE 802.1Q. It specifies a priority
value of between 0 (signifying best-effort)
and 7 (signifying priority real-time data)
that can be used by Quality of Service
disciplines to differentiate traffic.
SCSI Middle Layer. This is the SCSI
traffic handling layer. It directs requests
between the kernel and the SCSI.
SCSI Lower Layer. This is the SCSI
HBA driver. It communications directly
to the SCSI HBA.
CoS is a way of managing traffic in a
network by grouping similar types of traffic
(for example, e-mail, streaming video,
voice, large document file transfer)
together and treating each type as a class
with its own level of service priority.
The structure for Solaris SPARC drivers
includes:
Nexus Drivers. Nexus drivers provide
bus mapping and translation services
to subordinate nexus and leaf devices.
These include drivers for PCI-to-PCI
bridges, PCMCIA adapters, and SCSI
HBAs.
CSV file
A comma separated values (CSV) file
Leaf Drivers. Leaf drivers provide the
traditional character and block driver
interfaces for reading and writing data
to storage and communication
device
A target, typically a disk drive. Hardware
such as a disk drive, tape drive, printer, or
keyboard that is installed in or connected
to a system. In FC, a target device.
devices. These include drivers for
peripheral devices, including
QLA200/QLA2xxx HBAs, disks, tapes,
network HBAs, and frame buffers.
driver
The software that interfaces between the
file system and a physical data storage
device or network media.
Miniport Driver. The lowest driver level
and device specific. This level is
usually supplied by the manufacturer
as a companion to a physical device.
The level structure for Windows XP
Professional/2000/Windows Server 2003
drivers is as follows:
Monolithic Driver. This level combines
the functions of different driver levels in
the same driver to increase perfor-
mance.
Class Driver. The highest driver level.
There is a separate class for disk,
Ethernet, and so forth. This level
handles all generic aspects of opera-
tions for that class.
Adjunct Driver. This level works along
side a driver at the same level to
increase performance.
Glossary-2
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
SANsurfer iSCSI HBA CLI User’s Guide
Command Line Interface for QLogic iSCSI Host Bus Adapters
A
In NetWare, the required drivers include:
fabric
A fabric consists of cross-connected FC
devices and switches.
Host Adapter Module (HAM). HAM is
the driver component associated with
the host adapter hardware. It provides
the functionality to route requests to
the bus where a specified device is
attached.
fabric switch
Also, switched fabric. A fabric switch
connects multiple devices from indepen-
dent FC-arbitrated loops (FC-ALs) and
point-to-point topologies into a fabric using
FC switches.
Custom Device Module (CDM). The
drive component associated with
storage devices. It provides the
functionality to build device-specific
commands from I/O messages
received from NetWare’s Media
Manager.
Fast!UTIL
QLogic Fast!UTIL FC HBA BIOS utility.
FCode
E_Port
A type of boot code for Sun's SPARC
platforms. See boot code and Flash.
Expansion port. A port in an FC switch that
connects to another FC switch or bridge
device by an inter-switch link. E_Ports are
used to link FC switches to form a
multi-switch fabric.
FC
Fibre Channel is a high-speed serial inter-
face technology that supports other higher
layer protocols such as SCSI and IP.
echo diagnostic test
FCoE
Transmits a received signal back to the
sender to verify the integrity of the device.
technology defined by the T11 standards
body that allows traditional FC storage
Ethernet link by encapsulating FC frames
inside Layer 2 Ethernet frames. For more
Enhanced Ethernet
Also called DataCenter Ethernet or
Converged Enhanced Ethernet) refers to
new enhancements to the existing
Ethernet standard that eliminate Ethernet’s
inherently lossy nature and make 10Gb
Ethernet a viable storage networking
transport.
FL_Port
Fabric loop port. In an FC, the fabric switch
is capable of FC Arbitrated Loop opera-
tions and is connected to one or more
NL_Ports by an FC Arbitrated Loop. An
FL_Port becomes a shared entry point for
public NL_Port devices to an FC fabric.
FL_Ports are intermediate ports in virtual
point-to-point links between end ports that
do not reside on the same loop, for
F_Port
The “Fabric” port in a FC fabric switch
provides a point-to-point link attachment to
a single N_Port. F_Ports are intermediate
ports in virtual point-to-point links between
end ports, for example N_Port to F_Port to
F_Port to N_Port using a single FC fabric
switch.
example NL_Port to FL_Port to F_Port to
N_Port through a single FC fabric switch.
SN0054621-00 E
Glossary-3
Download from Www.Somanuals.com. All Manuals Search And Download.
SANsurfer iSCSI HBA CLI User’s Guide
Command Line Interface for QLogic iSCSI Host Bus Adapters
S
Flash
Nonvolatile memory holding the boot code.
ioctl
Input/output control. A system call in
At times, Flash and boot code are used
interchangeably. (See boot code)
Unix/Linux systems. Allows an application
to control or communicate with a device
driver outside usual read/write operations.
Flash BIOS
JBOD
A flash PROM contains the BIOS code for
the HBA.
“Just a bunch of disks.” As opposed to a
SAN. See SAN.
G_Port
L_Port
Generic port. A port that can operate as
either an E_Port or an F_Port. A G_Port
can determine operating mode at switch
port initialization, F_Port when an N_Port
attachment is determined, E_Port when an
E_Port attachment is determined. See
E_Port, F_Port, FL_Port, L_Port, N_Port
(Node Port), NL_Port (Node Loop Port)
Loop port. Does arbitrated loop functions
and protocols. NL_Ports and FL_Ports are
examples of loop-capable ports. See
E_Port, F_Port, FL_Port, G_Port, N_Port
(Node Port), NL_Port (Node Loop Port).
LIP
Loop initialization process. The initializa-
tion process in an arbitrated loop that
occurs when the loop is powered up or a
new device is added. One function of a LIP
is to assign addresses. All data transmis-
sion on the loop is suspended during a LIP.
HBA
Host bus adapter. The board that inter-
faces between the host system and the
target devices. HBA is synonymous with
adapter, host adapter, and adapter board.
HBA alias
A user-defined name for an HBA.
load balancing
A software feature that improves system
performance by balancing device access
between multiple HBAs for maximum
resource efficiency. Available in Windows
2000/Windows Server 2003, Novell
NetWare, and Red Hat/SUSE Linux.
HBA port
A port on the HBA board.
HBA port alias
A user-defined name for an HBA port.
loopback
HBA port beacon
Diagnostic tool that routes transmit data
through a loopback connector back to the
same HBA.
An LED on the HBA. Flashing it enables
you to locate the HBA.
IOCB
loop ID
I/O control block. An IOCB is a command
structure in QLogic ISP architecture.
The device’s AL_PA on the loop.
Glossary-4
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
SANsurfer iSCSI HBA CLI User’s Guide
Command Line Interface for QLogic iSCSI Host Bus Adapters
A
LUN
N_Port ID Virtualization
Logical Unit Number, a subdivision of a
SCSI target. It is the small integer handle
that differentiates an individual disk drive
or partition (volume) within a common
SCSI target device such as a disk array.
The ability for a single physical FC end
point (N_Port) to support multiple, uniquely
addressable, logical end points. With
NPIV, a host FC adapter is shared in such
a way that each virtual adapter is assigned
to a virtual server and is separately identifi-
able within the fabric. Connectivity and
access privileges within the fabric are
controlled by identification of each virtual
adapter and, hence, the virtual server
using each virtual adapter.
Technically, a LUN can be a single
physical disk drive, multiple physical disk
drives, or a portion (volume) of a single
physical disk drive. However, LUNs are
typically not entire disk drives but rather
virtual partitions (volumes) of a RAID set.
Using LUNs, the FC host can address
multiple peripheral devices that may share
a common controller.
NL_Port (Node Loop Port)
A port capable of arbitrated loop functions
and protocols. An NL_Port connects
through an arbitrated loop to other
NL_Port and at most a single FL_Port.
NL_Ports handle creation, detection, and
flow of message units to and from the
connected systems. NL_Ports are end
ports in virtual point-to-point links through
a fabric, for example NL_Port to F_Port to
F_Port to N_Port using a single FC fabric
switch. In the absence of a fabric switch
FL_Port, NL_Ports can communicate with
other NL_Ports in virtual point-to-point
links through a FC_AL open loop circuit
often through FC_AL (Arbitrated Loop)
hub or loop switch devices. See: E_Port,
F_Port, FL_Port, G_Port, N_Port (Node
Port).
LUN masking
A software feature that assigns LUNs to
specific servers or hides LUNs from
specific servers for maximum access and
availability control.
media
Physical-layer information carriers. FC
supports several different physical media:
copper, multimode optical, and
single-mode optical. All FC protocols are
supported on all media.
NPIV
N_Port ID Virtualization.
N_Port (Node Port)
NIC
A port that connects by a point-to-point link
to either a single N_Port or a single
F_Port. N_Ports handle creation, detec-
tion, and flow of message units to and from
the connected systems. N_Ports are end
ports in virtual point-to-point links through
a fabric, for example N_Port to F_Port to
F_Port to N_Port using a single FC fabric
switch. See FL_Port.
Network Interface Controller.
NVRAM
Non-volatile random access memory. A
type of memory that retains data even
when power is removed. Holds configura-
tion settings. You can configure NVRAM
settings manually or restore them from a
file. These settings are retained when
power is removed. NVRAM settings are
called HBA parameters in this guide.
SN0054621-00 E
Glossary-5
Download from Www.Somanuals.com. All Manuals Search And Download.
SANsurfer iSCSI HBA CLI User’s Guide
Command Line Interface for QLogic iSCSI Host Bus Adapters
S
network adapter
NL_Port (Node Loop Port)—an FC
port that supports loop topology.
A chip that provides network capabilities. A
computer may include a network adapter
on its system board, or on an adapter card.
Also a NIC (network interface card or
controller).
FL_Port—a port in a fabric where an
N_Port can attach.
FL_Port—a port in a fabric where an
NL_Port can attach.
ONC
port instance
The number of the port in the system.
Open network computing. A remote proce-
dure call developed by Sun Microsystems.
Each HBA may have one or multiple ports,
identified with regard to the HBA as port 0,
port 1 and so forth. to avoid confusion
when dealing with a system containing
numerous ports, each port is assigned a
port instance number when the system
boots up. So Port 0 on an HBA might have
a port instance number of, for example, 8 if
it is the eighth port discovered by the
system.
path
A path to a device is a combination of a
HBA port instance and a target port as
distinct from internal paths in the fabric
network. A fabric network appears to the
operating system as an opaque network
between the HBA (initiator) and the target.
Since a path is a combination of an HBA
and a target port, it is distinct from another
path if it is accessed through a different
HBA and/or it is accessing a different
target port. Consequently, when switching
from one path to another, the driver might
be selecting a different HBA (initiator), a
different target port, or both.
SAN
Storage area network. Multiple storage
units (disk drives) and servers connected
by networking topology.
SCSI
Small computer system interface. A
high-speed interface used to connect
devices, such as hard drives, CD drives,
printers, and scanners, to a computer. The
SCSI can connect many devices using a
single controller. Each device is accessed
by an individual identification number on
the SCSI controller bus.
This is important to the driver when
selecting the proper method of failover
notification. It can make a difference to the
target device, which might have to take
different actions when receiving retries of
the request from another initiator or on a
different port.
point-to-point
target
Also FC-P2P. Two FC nodes directly
connected (not in a loop).
The storage-device endpoint of a SCSI
session. Initiators request data from
targets. Targets are typically disk-drives,
tape-drives, or other media devices.
Typically a SCSI peripheral device is the
target but an HBA may, in some cases, be
a target. A target can contain many LUNs.
port
Access points in a device where a link
attaches. There are four types of ports, as
follows:
N_Port (Node Port)—an FC port that
supports point-to-point topology.
Glossary-6
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
Index
alias 4-48
HBA 4-49
A
-acb 5-3
Arbitrated Loop_Physical Address, definition
of Glossary-1
ARP
adding 4-42
redirect A-3
targets 4-40
address
IPv6 5-22
MAC 4-12
port 5-14
B
bidirectional (BIDI) CHAP, default,
adding 4-43
BIOS
SN0054621-00 E
Index-1
Download from Www.Somanuals.com. All Manuals Search And Download.
SANsurfer iSCSI HBA CLI User’s Guide
Command Line Interface for QLogic iSCSI Host Bus Adapters
S
boot
target information
iSCSI bidirectional CHAP
authentication A-6
comma separated values (CSV) file, definition
of Glossary-2
bootcode
command line
format 5-1
installation 2-9
uninstall 2-12
variables 5-2
commands
non-interactive 5-1
-acb 5-3
C
cache
CHAP
authentication C-4
bidirectional authentication, target iSCSI
I/O C-4
configuring 4-40
entry 4-42
adding 5-3
-df 5-8
-dp 5-8
Index-2
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
SANsurfer iSCSI HBA CLI User’s Guide
Command Line Interface for QLogic iSCSI Host Bus Adapters
A
commands (continued)
-dtdsp 5-9
-ps 5-25
-pu 5-25
-dtdspa 5-9
-px 5-26
-dtli 5-10
-dtlia 5-10
-rdf 5-26
-dtrem 5-10
-dtrema 5-11
-dv 5-11
-sbootcode 5-29
-sdmrc 5-29
-ei 5-12
-stadd 5-29
-fa 5-12
-stathba 5-30
-g 5-13
-stdsp 5-30
-strd 5-30
-strem 5-30
-ip 4-27
-strema 5-30
-model 5-19
-pad 5-24
-pdt 5-24
-tf 5-31
-tp 5-31
-ver 5-31
-z 5-32
configuration
exporting 5-28
configuring
-pet 5-24
-pinfo 5-24
SN0054621-00 E
Index-3
Download from Www.Somanuals.com. All Manuals Search And Download.
SANsurfer iSCSI HBA CLI User’s Guide
Command Line Interface for QLogic iSCSI Host Bus Adapters
S
configuring (continued)
manual 5-21
default
connection error log
displaying 4-32
exporting 4-33
Converged Enhanced Ethernet, definition
of Glossary-3
converged network adapter, definition
of Glossary-2
core
retrieving 4-16
CoS (Class of Service), definition
of Glossary-2
Custom Device Module (CDM), definition
of Glossary-3
DefaultTime2Retain A-2
DefaultTime2Wait A-2
deleting
targets 4-29
device
type C-2
-df 5-8
DHCP 5-4
configuring 4-21
TCP A-8
TCP_DCHP 4-26
diagnostics
customer card identification number,
viewing 4-18
HBA 4-15
port 4-29
D
digests
disabling
data
immediate C-4
target 5-24
Index-4
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
SANsurfer iSCSI HBA CLI User’s Guide
Command Line Interface for QLogic iSCSI Host Bus Adapters
A
discovered targets
removing 5-10
target
targets
port 5-24
documentation
discovery
related 1-3
downloading
-dp 5-8
displaying
CHAP
driver
targets 4-41
version 4-12
-dtdsp 5-9
configured
firmware
-dtdspa 5-9
parameters 4-22
properties 5-8
-dtli 5-10
HBA
-dtlia 5-10
-dtrem 5-10
information 4-12
-dtrema 5-11
dumping
NVRAM 4-15
-dv 5-11
SN0054621-00 E
Index-5
Download from Www.Somanuals.com. All Manuals Search And Download.
SANsurfer iSCSI HBA CLI User’s Guide
Command Line Interface for QLogic iSCSI Host Bus Adapters
S
exporting
E
E_Port (Expansion Port), definition
of Glossary-3
F
editing
-fa 5-12
FCode
settings 4-34
-ei 5-12
enabling
DHCP 5-16
updating 4-13
target 5-24
firmware
error
See Also firmware parameters
QLA4010, restoring default port
settings 4-28
exit to higher level (interactive menu
mode) 4-50
Index-6
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
SANsurfer iSCSI HBA CLI User’s Guide
Command Line Interface for QLogic iSCSI Host Bus Adapters
A
firmware parameters
IPv6_TCP_Timer_Scale A-5
AFW_Device_TO 4-25
IPv6_TCP_Window_Scale A-5
IPv6_Traffic_Class A-6
IPv6_VLAN_Enable A-6
IPv6_VLAN_ID A-6
Default_IPv6_Router A-2
DefaultTime2Retain A-2
DefaultTime2Wait A-2
Enable_4022IPv4 A-2
IPv6_VLAN_User_Priority A-6
IPv6MCast_listnr_Disco_Enable A-4
iSCSI_BIDI_CHAP_Auth A-6
iSCSI_CHAP_Auth A-6
Enable_IPv4 A-2
Enable_IPv6 A-2
FW_Accept_AEN A-2
FW_Access_Control A-2
FW_Fast_Posting A-3
FW_Initiator_Mode A-3
FW_Marker A-3
FW_Sense_Buffer_Desc A-3
IP_Fragmentation A-3
iSCSI_Data_PDU_In_Order A-6
iSCSI_Data_Seq_In_Order A-6
iSCSI_Error_Recovery_Level A-6
iSCSI_Name 4-27
iSCSI_Send_Markers A-7
LDROUTER_AUTO A-8
LOC_LINK_AUTO A-8
MaxRxDataSegmentLen A-8
port A-8
IPv4_TOS_Enable A-4
IPv6_Addr_Local_Link A-4
IPv6_Addr_Routable0 A-4
IPv6_Addr_Routable1 A-4
IPv6_Gratuitous_Neighbor_Ad_Enable A-4
IPv6_Hop_Limit A-4
ROUTABLE_AUTO A-8
TCP_Auto_Discovery 5-20
TCP_Timer_Scale A-9
TCPMaxWindowSize 5-20
viewing 4-22
IPv6_Nagle A-4
IPv6_ND_Reachable_Timer A-5
IPv6_ND_Retransmit_Timer A-5
IPv6_ND_Stale_Timeout A-5
IPv6_Port A-5
IPv6_Redirect_Enable A-5
IPv6_TCP_Time_Stamp A-5
SN0054621-00 E
Index-7
Download from Www.Somanuals.com. All Manuals Search And Download.
SANsurfer iSCSI HBA CLI User’s Guide
Command Line Interface for QLogic iSCSI Host Bus Adapters
S
firmware parameters (continued)
ZIO_Enable_Mode A-3
H
HBA_Default_Fragment_Reass_Timeout
parameter A-10
HBA_Reserved_TCP_ Config
parameter A-10
HBAs
Flash
dumping 4-15
Force_Negotiate_Main_iSCSI_Keys
configuration
exporting 5-28
saving 4-9
G
diagnostics 4-15
G_Port (Generic Port), definition
of Glossary-4
driver
firmware
guide
updating 5-12
Index-8
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
SANsurfer iSCSI HBA CLI User’s Guide
Command Line Interface for QLogic iSCSI Host Bus Adapters
A
HBAs (continued)
model 5-14
I
ID
target C-3
VLAN A-9
operations 4-12
options 4-13
image
info
information
ports 4-19
initiator
entry C-5
mode A-3
input/output control (ioctl), definition
of Glossary-4
installation
settings 5-5
header digests
Host Adapter Module (HAM), definition
of Glossary-3
Host Adapter Module (HAM), NetWare
SN0054621-00 E
Index-9
Download from Www.Somanuals.com. All Manuals Search And Download.
SANsurfer iSCSI HBA CLI User’s Guide
Command Line Interface for QLogic iSCSI Host Bus Adapters
S
installation (continued)
IPv4
disabling 5-22
enabling A-2
TOS_Enable A-4
Windows 2-4
instance
port 5-14
IPv4_TOS C-2
starting 3-1
IOCB
IPv6
marker A-3
ioctl (input/output control), definition
of Glossary-4
address C-3
IP
configuring 4-27
disabling 5-22
fragmentation A-3
-ip 4-27
IP address
redirect C-3
duplicate address detection (DAD) A-4
Nagle A-4
port A-5
ports 4-28
redirect 4-28
Index-10
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
SANsurfer iSCSI HBA CLI User’s Guide
Command Line Interface for QLogic iSCSI Host Bus Adapters
A
IPv6 (continued)
iSCSI
TGT_Flow_Label C-2
IPv6_Addr_Local_Link 4-26
IPv6_Gratuitious_Neighbor_Ad_Enable
parameter 4-28
IPv6_Gratuitous_Neighbor_Ad_Enable
parameter A-4
IPv6_MCast_Listnr_Disco_Enable
parameter 4-27
version 4-12
iSCSI_Alias 4-26
iSCSI_Immediate_Data 4-27
IPv6MCast_listnr_Disco_Enable
parameter A-4
SN0054621-00 E
Index-11
Download from Www.Somanuals.com. All Manuals Search And Download.
SANsurfer iSCSI HBA CLI User’s Guide
Command Line Interface for QLogic iSCSI Host Bus Adapters
S
iSNS
link configuration
Linux
enabling 4-21
SUSE 2-3
uninstall 2-12
LIP
List All QLogic iSCSI HBA Ports
Detected 4-48
listing
J
JBOD (Just a Bunch of Disks), definition
of Glossary-4
targets 4-37
local link address
K
setting 5-16
Logical Unit Number (LUN), definition
of Glossary-5
L
logout
strict C-5
Index-12
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
SANsurfer iSCSI HBA CLI User’s Guide
Command Line Interface for QLogic iSCSI Host Bus Adapters
A
LUNs
Refresh 4-49
number 5-17
mode
bootcode 5-4
initiator A-3
interactive 3-1
non-interactive (command line),
starting 3-2
M
ZIO 4-26
-model 5-19
maximum
multicast listener discovery protocol,
IPv6 A-4
N
N_Port ID Virtualization, definition
of Glossary-5
name
HBA 4-49
ND
menus, main
Exit 4-50
netmask 5-16
Help 4-49
List All QLogic iSCSI HBA Ports
Detected 4-48
setting 5-21
SN0054621-00 E
Index-13
Download from Www.Somanuals.com. All Manuals Search And Download.
SANsurfer iSCSI HBA CLI User’s Guide
Command Line Interface for QLogic iSCSI Host Bus Adapters
S
Network Interface Controller (NIC), definition
of Glossary-5
P
-pad 5-24
configuring 5-21
displaying 4-20
parameters
iSCSI_Send_Markers A-7
optional 5-1
required 5-1
target C-1
starting 3-2
-pdt 5-24
-pet 5-24
-pinfo 5-24
Non-volatile Random Access Memory
number
HBA 5-14
LUN 5-17
NVRAM
dumping 4-15
retrieving 5-11
port
target C-3
ports
diagnostics 4-29
O
Open Network Computing (ONC), definition
of Glossary-6
supported 1-4
operations
host 4-8
port 4-19
Index-14
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
SANsurfer iSCSI HBA CLI User’s Guide
Command Line Interface for QLogic iSCSI Host Bus Adapters
A
ports (continued)
instance 5-14
number A-8
R
R2T
initial C-4
-rdf 5-26
receive
markers C-4
records
Red Hat
uninstall 2-13
Red Hat/SUSE Linux driver
layers Glossary-2
redirect
enabling A-5
option C-3
resetting 4-14
PPC
uninstall 2-13
primary
priority
product
-ps 5-25
-pu 5-25
-px 5-26
removing
Q
QLogic
contacting 1-5
SN0054621-00 E
Index-15
Download from Www.Somanuals.com. All Manuals Search And Download.
SANsurfer iSCSI HBA CLI User’s Guide
Command Line Interface for QLogic iSCSI Host Bus Adapters
S
resetting
restoring
retrieving
S
SAN (Storage Area Network), definition
of Glossary-6
saving
scale
timer C-5
SCSI
-sdmrc 5-29
return codes
routable
auto A-8
secondary
send targets
adding 5-29
rediscovering 5-30
viewing 5-30
router
running
silent installation
Solaris 2-11
Windows 2-9
Small Computer System Interface (SCSI),
Index-16
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
SANsurfer iSCSI HBA CLI User’s Guide
Command Line Interface for QLogic iSCSI Host Bus Adapters
A
snack
system
Solaris
SPARC 2-3
x86 2-3
Solaris SPARC/Solaris x86
installation 2-10
T
setting 5-31
uninstall 2-13
TGT_4022_Delayed_Ack C-2
TGT_DefaultTime2Retain C-2
TGT_DefaultTimeout C-2
TGT_DevType C-2
TGT_Dif_Enable C-2
TGT_ExeCount C-2
-stadd 5-29
starting
-stathba 5-30
statistics
HBA 4-16
resetting 4-32
-stdsp 5-30
Storage Area Network (SAN), definition
of Glossary-6
-strd 5-30
-strem 5-30
-strema 5-30
strict login
iSCSI 4-24
TGT_ExeThrottle C-2
TGT_FirstBurstLen C-2
TGT_Force_Negotiate_Main_iSCSI_Keys
TGT_InitiatorSessID C-2
TGT_IPv6_Address C-2
TGT_IPv6_Flow_Label C-2
TGT_IPv6_iSCSI_Name C-2
TGT_IPv6_Port C-3
TGT_IPv6_Source_Add_Flg C-3
TGT_iSCSI_Name C-3
TGT_KeepAliveTimeout C-3
TGT_Local_IPv6_Address C-3
TGT_Local_TCP_Port C-3
TGT_Max_Seg_Size C-3
TGT_MaxBurstLen C-3
TGT_MaxOutstandingR2T C-3
TGT_MaxRxDataSegmentLen C-3
TGT_MaxTxDataSegmentLen C-3
TGT_Perm_Redirect_Option C-3
TGT_Port C-3
SUSE Linux
TGT_Redirect_IPAddr C-3
TGT_Redirect_IPAddr_State C-3
TGT_RetryCount C-3
TGT_RetryDelay C-3
TGT_Rx_Window_Scale C-3
uninstalling 2-13
SN0054621-00 E
Index-17
Download from Www.Somanuals.com. All Manuals Search And Download.
SANsurfer iSCSI HBA CLI User’s Guide
Command Line Interface for QLogic iSCSI Host Bus Adapters
S
target parameters (continued)
TGT_TimeStamp_Enable C-4
TGT_Traffic_Class C-4
CHAP entry
adding 4-42
deleting 4-29
disabling 5-24
discovered
removing 5-10
enabling 5-24
parameters
configuring 4-39
rediscovering 5-30
send
TGT_Tx_Window_Scale C-4
TGT_Type_of_Service C-4
TGT_Window_Scale_Enable C-4
TGTCPO_Nagle C-5
TGTCPO_Timer_Scale C-5
TGTCPO_Timestamp C-5
TGTIPO_Fragementation C-4
TGTISCISO_Data_Digests C-4
TGTISCSIO_Bidi_CHAP_Authentication
TGTISCSIO_Data_PDU_In_Order C-4
TGTISCSIO_Data_Sequence_In_Order
TGTISCSIO_Error_Recovery_Level C-4
TGTISCSIO_Header_Digests C-4
TGTISCSIO_Immediate_Data C-4
TGTISCSIO_Initial_R2T C-4
TGTISCSIO_Receive_Markers C-4
TGTISCSIO_Send_Markers C-5
TGTISCSIO_Snack C-5
TGTO_Access_Granted C-5
TGTO_Active C-5
TGTO_Initiator_Entry C-5
TGTSCSIO_CHAP_Authentication C-4
TGTSCSIO_Discovery_Logout C-4
TGTSCSIO_Strict_Login C-5
TGTSCSIO_Strict_Logout C-5
targets
removing 5-30
viewing 5-30
viewing 5-24
task management,
See Also target parameters
adding 4-40
boot target information
Index-18
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
SANsurfer iSCSI HBA CLI User’s Guide
Command Line Interface for QLogic iSCSI Host Bus Adapters
A
TCP
TGT_IPv6_Source_Add_Flg C-3
TGT_iSCSI_Name C-3
DHCP A-8
TCP_DHCP 5-20
TCP_Auto_Discovery 5-20
TGT_KeepAliveTimeout C-3
TGT_Local_IPv6_Address C-3
TGT_Local_TCP_Port C-3
TGT_Max_Seg_Size C-3
TGT_MaxBurstLen C-3
TGT_MaxOutstandingR2T C-3
TGT_MaxRxDataSegmentLen C-3
TGT_MaxTxDataSegmentLen C-3
TGT_Perm_Redirect_Option C-3
TGT_Port C-3
TGT_Redirect_IPAddr C-3
TGT_Redirect_IPAddr_State C-3
TGT_RetryCount C-3
TGT_RetryDelay C-3
TGT_Rx_Window_Scale C-3
availability 1-5
training 1-5
tests
TGT_TimeStamp_Enable C-4
TGT_Traffic_Class C-4
TGT_Tx_Window_Scale C-4
TGT_Type_of_Service C-4
TGT_Window_Scale_Enable C-4
TGTCPO_Nagle C-5
TGT_4022_Delayed_Ack C-2
TGT_DefaultTime2Retain C-2
TGT_DefaultTimeout C-2
TGT_DevType C-2
TGT_Dif_Enable C-2
TGT_ExeCount C-2
TGT_ExeThrottle C-2
TGT_FirstBurstLen C-2
TGT_Force_Neg._Main_iSCSI_Keys C-2
TGT_InitiatorSessID C-2
TGT_IPv6_Address C-2
TGT_IPv6_Flow_Label C-2
TGT_IPv6_iSCSI_Name C-2
TGTCPO_Timer_Scale C-5
TGTCPO_Timestamp C-5
TGTIPO_Fragmentation C-4
TGTISCISO_Data_Digests C-4
TGTISCSIO_Bidi_CHAP_Authentication C-4
TGTISCSIO_Data_PDU_In_Order C-4
TGTISCSIO_Data_Sequence_In_Order C-4
TGTISCSIO_Error_Recovery_Level C-4
TGTISCSIO_Header_Digests C-4
TGTISCSIO_Immediate_Data C-4
TGTISCSIO_Initial_R2T C-4
TGTISCSIO_Receive_Markers C-4
TGTISCSIO_Send_Markers C-5
TGTISCSIO_Snack C-5
TGTO_Access_Granted C-5
SN0054621-00 E
Index-19
Download from Www.Somanuals.com. All Manuals Search And Download.
SANsurfer iSCSI HBA CLI User’s Guide
Command Line Interface for QLogic iSCSI Host Bus Adapters
S
TGTO_Active C-5
TGTO_Initiator_Entry C-5
U
uninstall
interactive 2-12
Linux 2-12
passive 2-12
quiet 2-12
TGTSCSIO_CHAP_Authentication C-4
TGTSCSIO_Discovery_Logout C-4
TGTSCSIO_Strict_Login C-5
TGTSCSIO_Strict_Logout C-5
time stamp
enable C-4
Windows 2-12
timeouts
updating
timers
IPv6_ND_Reachable A-5
V
-tp 5-31
version 4-8
trace
chip 4-12
levels F-2
using F-1
variables F-2
iSCSI 4-12
iSDMAPI 4-9
ROM 4-12
IPv6 A-6
-ts 5-31
Index-20
SN0054621-00 E
Download from Www.Somanuals.com. All Manuals Search And Download.
SANsurfer iSCSI HBA CLI User’s Guide
Command Line Interface for QLogic iSCSI Host Bus Adapters
A
VLAN
X
Z
-z 5-32
ZIO
configuring 4-27
mode 4-26
parameter A-9
W
window
Windows
installation
GUI 2-4
standard 2-4
uninstall 2-12
versions 2-2
SN0054621-00 E
Index-21
Download from Www.Somanuals.com. All Manuals Search And Download.
Corporate Headquarters QLogic Corporation 26650 Aliso Viejo Parkway Aliso Viejo, CA 92656 949.389.6000 www.qlogic.com
Europe Headquarters QLogic (UK) LTD. Quatro House Lyon Way, Frimley Camberley Surrey, GU16 7ER UK +44 (0) 1276 804 670
D
© 2008 QLogic Corporation. Specifications are subject to change without notice. All rights reserved worldwide. QLogic, QLA, SANblade, SANbox, SANsurfer, and the QLogic logo are regis-
tered trademarks of QLogic Corporation. Linux is a registered trademark of Linus Torvalds. Microsoft and Windows are registered trademarks and Windows Server is a trademark of Microsoft
Corporation. Red Hat and all Red Hat-based trademarks are trademarks or registered trademarks of Red Hat, Inc. Solaris is a registered trademark of Sun Microsystems, Inc. SPARC is a
registered trademark of SPARC International, Inc. Products bearing SPARC trademarks are based on an architecture developed by Sun Microsystems, Inc. SUSE is a registered trademark of
Novell, Inc. All other brand and product names are trademarks or registered trademarks of their respective owners. Information supplied by QLogic Corporation is believed to be accurate and
reliable. QLogic Corporation assumes no responsibility for any errors in this brochure. QLogic Corporation reserves the right, without notice, to make changes in product design or specifica-
tions.
Download from Www.Somanuals.com. All Manuals Search And Download.
|