INtroductIoN  
The Tsunami MP.11 Model 5012-SUR is a flexible wireless outdoor client that let  
you design solutions for point-to-point links and point-to-multipoint networks.  
The 5012-SUR is part of the Tsunami MP.11 product family, which is comprised  
of several additional products, including the 5054 Base Station and Subscriber  
Units, and the 5012-SUI Subscriber Unit for indoor installation; and the 5054-  
R, 5054-R-LR, and 2454-R Base Station and Subscriber Units for outdoor  
installation. The 5012-SUR is fully compatible with Base Station models 5054,  
5054-R, and 5054-R-LR.  
Key Features  
Some of the key features of the Tsunami MP.11 5012-SUR are:  
The use of a highly optimized protocol for outdoor situations  
Routing and bridging capability  
Asymmetric bandwidth management  
Management through a Web Interface, a Command Line Interface (CLI), or  
Simple Network Management Protocol (SNMP)  
Software and configuration upgrade through file transfer (TFTP)  
Integrated antenna  
VLAN support (configured on Base Station)  
This document shows the basics of setting up the units. For detailed  
information, see the Tsunami MP.11 Model 5012-SUR Installation and  
Management Guide.  
Page ꢀ  
Copyright © 2006 Proxim Wireless  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
PacKaGe coNteNts  
Each Tsunami 5012-SUR shipment includes the items listed in the following  
table. Verify that you have received all parts of the shipment.  
Note:..  
Cables are not provided with the unit.  
5012-SUR unit  
Band clamps (2)  
Installation CD  
All rights reserved  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Page ꢁ  
 
Hardware aNd soFtware INstallatIoN  
IMPORTANT!  
Before installing this product, see “Safety and Regulatory Information” on  
the product CD for important safety and regulatory compliance informa-  
tion.  
Notes:.  
Be sure to read the Release.Notes file on the installation CD as it contains  
software version and driver information that may not have been available  
when this document was produced.  
The Configure System window provides a selectable Country field that  
automatically provides the allowed bandwidth and frequencies for the  
selected country as well as, where applicable, Dynamic Frequency Selection  
(DFS) and Transmit Power Control (TPC).  
Equipment is to be used with and powered by an 802.3af-compliant power  
injector (purchased separately).  
Page 6  
Copyright © 2006 Proxim Wireless  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
step 1: choose a location  
To make optimal use of the unit, you must find a suitable location for the  
hardware. The range of the unit largely depends upon the position of the  
integrated antenna. Proxim recommends you do a site survey, observing the  
following requirements, before mounting the hardware.  
The location must allow easy disconnection of the unit from the power  
outlet if necessary.  
The unit must not be covered and the air must be able to flow freely around  
the unit.  
The unit must be kept away from vibration, excessive heat, and humidity,  
and kept free from dust buildup.  
The installation must conform to local regulations at all times.  
The units are designed to mount directly to a 1” - 1.5” pole (not included)  
using the supplied band clamps. An optional universal pole mounting kit is also  
available from Proxim (P/N 1087-UMK); this kit is designed to mount directly to  
a flat surface such as a roof, wall, or under an eave.  
As the units are electrically isolated from the mounting pole, there is no need to  
ground the unit.  
Caution!  
Local regulations may require the use of a lightning arrestor at the building  
ingress point. Be sure to comply with this and all local regulations. You  
can purchase the Proxim Lightning Protector MP.11/QB.11 (70251); see  
the documentation that comes with the unit for more information and  
installation instructions.  
All rights reserved  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Page 7  
 
step 2: attach cables  
Note:  
Depending on your application and location, you may find it easier to mount  
the unit before you attach cables to it. If this is the case, remove the cable  
cover (as explained in step 1 below), and then complete Step 3: Mount Unit  
to Pole. Return to this step for cabling instructions.  
1. With the laying unit face down, depress both buttons on the back of the  
5012-SUR unit, and pull the plastic cover downward to open. Remove  
cover.  
2. Connect one end of an Ethernet cable (5.5 mm/.217 in OD maximum; not  
supplied) to the unit’s LAN port.  
3. Route the Ethernet cable as shown below.  
4. Connect the other end of the Ethernet cable to the Data and Power Out  
port of the DC Injector.  
Note:  
You must use an 802.3af-compliant power injector, such as the Proxim 1-  
Port Power Injector (P/N 4301-xx).  
5. Connect one end of a second Ethernet cable (not supplied) to the Data In  
port of the DC Injector and the other end to a switch, hub, patch panel, or  
single computer:  
Use a straight-through Ethernet cable if you are connecting the unit to  
Page ꢂ  
Copyright © 2006 Proxim Wireless  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
a switch, hub, or patch panel.  
Use a cross-over Ethernet cable or adapter if you are connecting the  
unit to a single computer or most router ports.  
All rights reserved  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Page ꢃ  
step 3: Mount unit to Pole  
Mount the 5012-SUR to a pole as follows:  
1. Using a screwdriver, turn the screw on the band clamp counter-clockwise  
until the clamp opens.  
2. Place the back of the 5012-SUR against the pole such that the pole fits into  
the curved portion of the unit.  
3. With the 5012-SUR aimed in the direction of the BSU, slide the flat end of  
the band clamp around the pole and through the top opening in the 5012-  
SUR unit, threading the flat end of the band clamp into the metal catch at  
the other end.  
4. Using a 5/16” nutdriver or a screwdriver, turn the screw on the band clamp  
clockwise until it is tight enough to hold the unit in place  
Note:  
Do not fully tighten band clamps; you must first ensure a functional link to  
Page 10  
Copyright © 2006 Proxim Wireless  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
5. Repeat procedure to attach other band clamp through bottom opening in  
the 5012-SUR unit.  
Note:.  
Do not fully tighten band clamps; you must first ensure a functional link to  
the BSU (Step 4: View LEDs/Adjust Mounting).  
The mounted unit, using the optional Proxim universal pole mounting kit (P/N  
1087-UMK), is shown below.  
All rights reserved  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Page 11  
step 4: View leds/adjust Mounting  
LEDs are located in the cable compartment.  
When the unit is powered on, the 5012-SUR performs startup diagnostics.  
When startup is completed, the LEDs show the operational state of the 5012-  
SUR.  
The following table shows the status of the LEDs when the 5012-SUR is  
operational.  
Status  
Power  
Wireless.Link  
N/A  
Ethernet.Link  
N/A  
Starting up  
Three red blinks  
followed by a  
temporary solid  
amber  
Radio scanning  
WORP link is up  
No WORP link  
Blinking green  
Solid green  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
Blinking amber/  
green  
System failure  
Solid red  
N/A  
N/A  
N/A  
No traffic on  
Solid green  
Solid green  
interface  
Normal operation Solid green  
Blinking green  
N/A  
Blinking green  
N/A  
/ passing traffic  
Bootloader mode  
Permanent solid  
amber  
If a wireless link is not established with the BSU, adjust the direction of the unit  
so that the integrated antenna is more precisely aimed toward the BSU. When  
the Power LED is solid green, the link is correctly established.  
Page 12  
Copyright © 2006 Proxim Wireless  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
step 5: close cable compartment  
1. Ensure that the Ethernet cable is properly routed and exiting the unit  
through the notch at the bottom of the cable compartment.  
2. Position the cable cover so that the notch in the cover fits over the Ethernet  
cable (not pictured) and the large tabs on the cover are aligned below the  
holes in the unit.  
3. Align the small tabs in the bottom cover with the holes in the unit.  
4. Slide cover upward until all tabs (large and small) on the cover snap into  
their respective holes on the enclosure.  
All rights reserved  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Page 13  
 
The assembly with the cable cover attached is shown below.  
Page 1ꢀ  
Copyright © 2006 Proxim Wireless  
Download from Www.Somanuals.com. All Manuals Search And Download.  
step 6: tighten Band clamps  
1. Using a 5/16” nutdriver or a screwdriver, fully tighten both band clamps  
(maximum torque 50 kg-cm/3.6 lbf-ft).  
2. Secure Ethernet cable to the pole with cable ties. Provide some slack  
between the unit and the first cable tie, which should be within 12 inches of  
the unit. Continue to secure cable with cable ties at 3-foot intervals.  
The final assembly, using the optional Proxim universal pole mounting kit (P/N  
1087-UMK), is shown below.  
All rights reserved  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Page 1ꢁ  
 
step 7: Install documentation and software  
1. Place the CD in a CD-ROM drive. The installer normally starts  
automatically. (If the installation program does not start automatically,  
click setup.exe.on the installation CD.)  
2. Click the Install.Software.and.Documentation.button and follow  
the instructions displayed on the installer windows. The following  
documentation and software products are installed:  
Available from Start.>.All.Programs.>.Tsunami.>..  
MP.11.5012-SUR:  
-
-
-
-
-
-
-
-
-
Documentation (in Docs subdirectory):  
Installation and Management Guide  
Quick Installation Guide  
Reference Manual  
Safety and Regulatory Guide  
Release Notes  
MP.11 5012-SUR Online Help  
Scan Tool (in Scan Tool subdirectory)  
TFTP Server (in TFTP Server subdirectory)  
All of these items are also available from C:\Program.Files\  
Tsunami\MP.11.5012-SUR.  
Available from C:\Program.Files\Tsunami\MP.11.5012-SUR:  
-
-
-
-
-
Scan Tool program  
Documentation (in Docs folder): See list above  
Help files (in Help folder; click on index.htm to access)  
Extras folder containing TFTP Server and Scan Tool program  
MIBs (in MIBs folder)  
Page 16  
Copyright © 2006 Proxim Wireless  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
INItIalIzatIoN  
Connecting to the unit requires either:  
A direct physical connection with an Ethernet cable or with a serial RS-232  
cable  
A network connection  
Connecting with the Ethernet cable allows you to use of the Web Interface and  
SNMP in addition to the CLI. Connecting with a serial connection allows you to  
configure and manage the unit with the CLI.  
Using a serial connection, you can access the unit through a terminal emulation  
program such as HyperTerminal. (See “HyperTerminal Connection Properties” in  
the Tsunami MP.11 Reference Manual.)  
setting the IP address  
With ScanTool (a software utility that is included on the product installation  
CD), you can find out the current IP address of the unit and, if necessary,  
change it so that is appropriate for your network.  
ScanTool lets you find the IP address of a Tsunami MP.11 5012-SUR by  
referencing the MAC address in a Scan List, or to assign an IP address if the  
correct one has not been assigned. The tool automatically detects the units  
installed on your network segment, regardless of IP address, and lets you  
configure each unit’s IP settings. In addition, you can use ScanTool to download  
new software to a unit that does not have a valid software image installed.  
To discover and set/change the IP address of the unit:  
1. Run ScanTool on a computer connected to the same LAN subnet as the  
unit, or a computer directly connected to the unit with a cross-over  
Ethernet cable. Double-click the ScanTool icon on the Windows desktop to  
launch the program. If the icon is not on your desktop, click Start.>.All.  
Programs.>.Tsunami.>.MP.11.5012-SUR.>.Scan.Tool.  
ScanTool scans the subnet for 5012-SUR units and displays a list of the  
units it finds in the Scan List window (shown below). If necessary, click  
Rescan to re-scan the subnet and update the display.  
All rights reserved  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Page 17  
 
2. Select the unit for which you want to set the IP address and click Change.  
The Change dialog window is displayed.  
3. To set the IP address manually, ensure that Static is selected as the IP.  
Address.Type and fill in the IP.Address and Subnet.Mask suitable for  
the LAN subnet to which the unit is connected.  
To set the IP address dynamically, ensure that Dynamic is selected as  
the IP.Address.Type. The unit will request its IP address from a DHCP  
server on your network.  
4. Enter the Read/Write.Password (the default value is public) and click  
OK to confirm your changes. The respective unit reboots to make the  
changes effective.  
Page 1ꢂ  
Copyright © 2006 Proxim Wireless  
Download from Www.Somanuals.com. All Manuals Search And Download.  
accessing the web Browser  
To access the unit with a Web browser:  
1. Start your Web browser and enter the IP address of the unit in the  
Address box. The Web address should appear as http://<ip.address>  
(for example, http://10.0.0.1).  
A login window is displayed.  
2. A login window is displayed. Do not fill in the User name; enter only the  
default password public or the configured password.  
3. Upon successful login, the System.Status window is displayed.  
All rights reserved  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Page 1ꢃ  
 
accessing the command line Interface  
ethernet Port  
To use the CLI through the Ethernet port, you must have a telnet program, the  
CLI password, and the unit’s IP address.  
To access the unit through Ethernet on a Windows PC:  
1. Open a DOS command window: from the Windows Start menu, select  
Run; enter cmd.  
2. In the DOS window displayed, enter the IP address (for example, telnet  
10.0.0.1).  
3. Click OK to start the telnet program; you are prompted for your password.  
4. Enter the password (the default password is public).  
serial Port  
In some cases, it may not be possible to retrieve the unit’s IP address. In this  
case, you can connect to the serial port by connecting to the unit through the  
serial port. You still need the CLI password of the unit. Proxim recommends  
you power off the radio and the computer before connecting or disconnecting  
the serial cable.  
To access the unit through the serial port:  
1. Start your terminal program.  
2. Set the following connection properties; then connect:  
COM port:  
such as COM1 or COM2, to which the unit’s serial  
port is connected  
Bits per second:  
Data bits:  
Stop bit:  
9600  
8
1
Flow control:  
Parity:  
None  
None  
Line ends:  
Carriage return with line feed  
3. Disconnect and reconnect power to reset the unit. The terminal  
emulation program displays Power On Self Test (POST) messages. After  
approximately one minute (four minutes if DFS is enabled), you are  
prompted for your password.  
4. Enter the default password public.  
Page 20  
Copyright © 2006 Proxim Wireless  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
deFault settINGs  
Setting  
Default  
Mode of Operation  
Routing  
Bridge  
Disabled  
Static  
IP Address Assignment  
IP Address  
10.0.0.1  
255.255.255.0  
10.0.0.1  
64  
Subnet Mask  
Default Router IP Address  
Default TTL  
RIPv2 (if in routing Mode)  
Base Station System Name  
Network Name  
Enabled  
<blank>  
OR_WORP  
Chnl. 149,  
Frequency Channel  
5.745 GHz (for FCC devices)  
DFS Enabled (World Mode devices)  
Transmit Power Control  
Data Rate  
0 dB  
36 Mbps  
5
Registration Timeout  
Network Secret  
public  
Disabled  
20 MHz  
9600  
Turbo Mode  
Channel Bandwidth  
Serial Port Baud Rate  
SNMP Management Interface Enabled  
Telnet Management Interface Enabled  
HTTP Management Interface Enabled  
HTTP Port  
Telnet Port  
Password  
80  
23  
public  
250  
Maximum Satellites (per  
BSU)  
MAC Authentication  
Radius Authentication  
Encryption  
Disabled  
Disabled  
Disabled  
Static MAC Address Filter  
Ethernet Protocol Filtering  
Disabled / No Entries  
All Filters Disabled  
Disabled  
DFS Priority Frequency  
Channel  
Announcement Period (when 100 ms  
roaming enabled)  
All rights reserved  
Page 21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Setting  
Multi-Frame Bursting  
Storm Threshold  
Default  
Enabled  
Broadcast/Multicast Unlimited  
All Protocols Allowed  
Broadcast Protocol Filtering  
Dynamic Data Rate Selection Disabled  
Roaming  
Disabled  
Disabled  
Disabled  
NAT  
Intra-Cell Blocking  
Country Selection  
US-only device–US  
World device – GB  
DHCP Server  
Disabled  
Disabled  
Disabled  
0
DHCP Relay  
Spanning Tree Protocol  
Antenna Gain (For DFS  
Threshold compensation)  
Satellite Density  
VLAN Mode  
Large  
BSU: Transparent mode  
SU: Transparent mode when BSU is in  
Transparent mode; Trunk mode when BSU is in  
Trunk mode.  
Access VLAN ID  
BSU: N/A; SU: 1  
BSU: N/A; SU: 0  
BSU: -1; SU: -1  
BSU: 0; SU: 0  
Access VLAN Priority  
Management VLAN ID  
Management VLAN Priority  
VLAN ID in Trunk VLAN Table BSU: N/A; SU: 1  
Page 22  
Copyright © 2006 Proxim Wireless  
Download from Www.Somanuals.com. All Manuals Search And Download.  
tecHNIcal serVIces aNd suPPort  
If you are having trouble utilizing your Proxim product, please review the  
Tsunami MP.11 5012-SUR Installation and Management Guide and the  
additional documentation provided with your product.  
If you require additional support, please refer to the “Technical Services and  
Support” chapter in the Tsunami MP.11 5012-SUR Installation and Management  
Guide for details about the information you will need to gather before using the  
Support Options listed below.  
support options  
Proxim eservice web site support  
The Proxim eService Web site is available 7x24x365 at:  
telephone support  
Contact technical support via telephone as follows:  
Domestic: 866-674-6626  
International: +1-408-542-5390  
Hours.of.Operation  
North America: 8 a.m. to 5 p.m. PST, Monday through Friday  
EMEA: 8 a.m. to 5 p.m. GMT, Monday through Friday  
servPak support  
Proxim understands that service and support requirements vary from customer  
to customer. In recognition of these varying requirements we have developed  
a support program called ServPak. ServPak is a program of Enhanced Service  
Options that can be purchased individually or in combinations to meet your  
needs.  
Advanced Replacement  
Extended Warranty  
7x24x365 Technical Support  
Priority Queuing  
To learn more, please call Proxim Support at +1-408-542-5390 or send an  
email to [email protected]. To purchase ServPak support services, please  
contact your authorized Proxim distributor.  
All rights reserved  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Page 23  
 
2115 O’Nel Drive  
San Jose, CA  
(408) 731-2700  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Philips Baby Accessories SCF172 22 User Manual
Philips Battery Charger SCB5650NB 05 User Manual
Philips DVR 34DV2 User Manual
Philips Food Processor HR7633 User Manual
Philips Home Theater System HTR5000 User Manual
Plantronics Headphones 79534 01 User Manual
Porter Cable MP3 Player SA4005 User Manual
Poulan Snow Blower 437126 User Manual
Primera Technology Network Card PN 510725 121304 User Manual
PYLE Audio Car Stereo System PLCDCS100 User Manual