Fiber Cable Adaptability:  
The assembly is compatible with 10 mm diameter fiber optic bundles, SMA  
connectors, and FC connectors. See below.  
SMA Adapter  
PN 8401-032-44-20  
FC Adapter  
PN 8401-032-44-23  
10 mm sleeve  
PN 8405-232-05  
2
FC-446-021-U.DOC  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The following procedure is recommended for installing and aligning the  
FC-446-021-U and fiber optic bundles.  
1. Remove the entrance slit shipping cover to expose the slit baffle as shown  
below.  
4 Slotted Screws  
2. Using a flat-bladed screwdriver, remove the 4 slotted screws from the slit  
assembly.  
3. Remove the existing baffle from the slit assembly and install the 7/8” round  
baffle. See photograph below. Open the slit to approximately .5 mm.  
3
FC-446-021-U.DOC  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Mount the fiber optic input assembly with the 4 X 8-32 X 3/8” socket head  
cap screws provided.  
Fiber Cable and adapters:  
There are 4 different fiber cable/adapter set up configurations available for the input  
of the FC-446-021-U adapter assembly. Determine the type of fiber bundle to be  
installed. Install the desired fiber bundle as described in Set Up 1, 2, 3 or 4. After  
the installation, proceed to the Alignment Procedure on page 8.  
4
FC-446-021-U.DOC  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Set Up 1: FC Fiber Cable  
If the fiber cable has a single FC fiber, attach the FC adapter as shown below.  
Single fiber FC Cable  
FC Cable attached to FC Adapter  
Gently slide the cable/fiber assembly into the fiber optic input assembly so the  
end of the fiber adapter contacts the slits. Now pull the adapter back  
approximately .1 mm so it is no longer contacting the slits. Lock the fiber into  
place by tightening down the 3 set screws on the fiber optic input assembly. Do  
not move the cable so it contacts the slits while you are locking it into place.  
Contact with the slits can make them inoperable.  
Locking  
Set Screws  
Lock the Cable/Adapter into place with the 3 set screws.  
CAUTION: Never force the fiber optic bundle against the slits or  
permanent damage may result.  
5
FC-446-021-U.DOC  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Set Up 2: SMA Fiber Cable  
If the fiber cable has a single SMA fiber, attach the SMA adapter as shown  
below.  
Single Fiber SMA Cable  
SMA Cable attached to SMA Adapter  
Gently slide the cable/fiber assembly into the fiber optic input assembly so the  
end of the fiber adapter contacts the slits. Now pull the adapter back  
approximately .1 mm so it is no longer contacting the slits. Lock the fiber into  
place by tightening down the 3 set screws on the fiber optic input assembly. Do  
not move the cable so that it contacts the slits while you are locking it into place.  
Contact with the slits can make them inoperable.  
Locking  
Set Screws  
Lock the Cable/Adapter into place with the 3 set screws.  
CAUTION: Never force the fiber optic bundle against the slits or  
permanent damage may result.  
6
FC-446-021-U.DOC  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Set Up 3: 10 mm Diameter Sleeve with a single fiber  
Install the 10 mm sleeve to the X-Y adapter and lock it into place by tightening  
down the 3 set screws surrounding the adapter. Now gently slide the cable/fiber  
into the entrance of the fiber optic input assembly so the end of the fiber adapter  
contacts the slits. Now pull the adapter back approximately .1 mm so it is no  
longer contacting the slits. Lock the fiber into place by tightening down the set  
screw on the 10 mm sleeve. See below.  
CAUTION: Never force the fiber optic bundle against the slits or  
permanent damage may result.  
7
FC-446-021-U.DOC  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Set Up 4: 10 mm Diameter Sleeve with multiple fibers aligned in a row  
Install the 10 mm sleeve to the X-Y adapter and lock it into place by tightening  
down the 3 set screws surrounding the adapter. Note the orientation of the fibers  
in the sleeve of the fiber cable. Orient the fibers vertically and gently slide the  
cable/fiber into the entrance of the fiber optic input assembly so the end of the  
fiber adapter contacts the slits. Now pull the adapter back approximately .1 mm  
so it is no longer contacting the slits. Verify that the fibers are aligned vertically  
and then tighten down the set screw.  
Alignment Procedure:  
1. Adjust the vertical adjustment micrometer until the image of the fiber is  
centered in the height of the CCD or the center of the exit slit.  
2. Slowly reduce the entrance slit width to approximately the fiber core diameter  
of the fiber while adjusting the horizontal adjustment micrometer to center the  
fiber on the entrance slit for maximum signal.  
Note: If the fiber bundle consists of a series of fibers aligned vertically, it may  
be necessary to rotate the fiber to vertically align the fibers with the slit  
during this procedure.  
3. The fiber is now properly aligned.  
8
FC-446-021-U.DOC  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
15 Discovery Way, Acton, MA 01720  
Phone: (978)263-3584, Fax: (978)263-5086  
RECOMMENDED MINIMUM BEND RADIUS FOR FUSED SILICA FIBERS:  
Fiber Diameters  
MICRONS  
Momentary Min.  
INCHES  
Bend Radius  
Long Term Min.  
INCHES  
Bend Radius  
MILLIMETERS  
MILLIMETERS  
50  
100  
150  
200  
250  
300  
350  
400  
450  
500  
550  
600  
650  
700  
750  
800  
900  
1000  
1100  
1200  
1300  
1400  
1500  
1600  
0.20  
0.39  
0.59  
0.79  
0.98  
1.18  
1.38  
1.58  
1.77  
1.97  
2.16  
2.35  
2.55  
2.75  
2.95  
3.15  
3.54  
3.94  
4.33  
4.72  
5.12  
5.51  
5.90  
6.30  
5
10  
15  
20  
25  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
90  
100  
110  
120  
130  
140  
150  
160  
0.59  
1.18  
1.77  
2.36  
2.95  
3.54  
4.13  
4.72  
5.31  
5.90  
6.50  
7.09  
7.98  
8.27  
8.86  
9.45  
10.63  
11.81  
12.99  
14.17  
15.35  
16.54  
17.72  
18.90  
15  
30  
45  
60  
75  
90  
105  
120  
135  
150  
165  
180  
195  
210  
225  
240  
270  
300  
330  
360  
390  
420  
450  
480  
Minimum bend DIAMETER is equal to the radius X2.  
Momentary means minutes.  
9
FC-446-021-U.DOC  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Philips Bottle Warmer SCF121 12 User Manual
Philips CD Player AZ1017 User Manual
Philips Flat Panel Television 15PF9937 User Manual
Philips Home Theater System MX6000I 37 User Manual
Pinnacle Design TV Video Accessories TV24203 User Manual
Planar Car Video System PE1700 User Manual
Planar Car Video System PX2411MW User Manual
Porter Cable Cordless Saw 643 User Manual
Porter Cable Portable Generator H1000IS W User Manual
Poulan Lawn Mower 188781 User Manual