INSTALLATION MANUAL  
PROJECTOR MOUNT MODEL  
PSD-VHSA  
3130 E. Miraloma Ave. Anaheim, CA 92806 Phone: 800 368-9700 Fax: 800 832-4888  
VISIT US AT WWW.PREMIERMOUNTS.COM  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Safety & Precautions  
WARNING: Safety precaution measures must be practiced at all times during the installation of this product. Use proper safety gear and tools for the  
installations procedure to prevent personal injury or damage to the plasma displays or plasma mounts.  
The floor or tabletop structure must be capable of supporting at least five (5) times the weight of plasma display. If not, the floor or tabletop  
must be reinforced. Proper installation procedure by qualified personnel as outlined in the installations instructions must be adhered to.  
Failure to do so could result in serious personal injury  
The entire installation instructions should be fully read and understood, including all of the safety symbols and safety precautions, before  
beginning installation. The installation instructions should be read, understood and followed to prevent personal injury or property damage.  
Keep these installation instructions in an easily accessible location for future reference.  
Indicates that the power plug is to be disconnected from  
the power outlet.  
Contact Premier Mounts for any questions  
Safety precautions must be taken at all times.  
Warning and caution in general  
A suitable floor or tabletop must always support the weight or load of the plasma. Always confirm the weight load of the installation  
structure before installing the PSD-VHSA stand.  
Do not install in locations where there is vibration, movement or danger of impact. Failure to do so could result in plasma cracking or  
tipping over from the floor or tabletop causing damage to the plasma and injury.  
Do not install near heater, fireplace, direct sunlight or air conditioning or any other source of direct heat energy. Failure to do so may  
result in damage to the plasma display.  
At least two qualified people should always perform the installation work. Injury and damage can result from dropping or mishandling  
the plasma display.  
- 3 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Mount Diagrams  
A
B
C
D
E
2" Tubing  
PSD-VHSA  
Cable access point  
PP-SPA Height adapter  
Base plate  
MATERIAL:  
4 (ga) P & O base plate &  
2" (dia) tubing  
COLOR: Sinterflex  
Table top mounting points  
4.374  
2.375  
Side  
Front  
A
B
29.020  
14.522  
0.448  
12.998  
25.747  
160°  
D
6.000  
4.500  
E
6.000  
4.500  
Ø0.250  
C
Ø2.375  
75°  
6.499  
1.500  
3.023  
Ø2.000  
4.374  
PP-SPA adapter  
21.103  
Top  
- 4 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Getting the plasma ready  
WARNING: Proper installation procedure by qualified personnel as outlined in the installation instructions must be adhered to. Failure to do so could  
result in serious personal injury and possible damage to the plasma display.  
Step 1  
NOTE: Refer to the PSM or CTM series installation instructions to secure the mounting bracket to the plasma display.  
Set the PSD-VHSA on the floor and loosely install the PP-SPA adapter over the tubes flat side facing out, attach the two (2) M8 x 10 socket head screws to the  
adapter and slowly drop it to all the way until it touches the base. See figure 1.  
PP-SPA  
Allen wrench  
Adapter  
(2) M8 x 10 hex  
head screws  
Base  
Step 2  
Choose the proper location for the PSD-VHSA and make sure that the location is weight suitable (see warnings). Using (commercially available) suitable hardware  
depending on you installation environment the two holes found on the base may be used if needed to fasten the stand to the surface. See figure 2.  
PP-SPA  
Adapter  
Suitable hardware  
(commercially available)  
Base  
Suitable surface  
(see warning)  
- 5 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Measuring the plasma  
Step 3  
With the plasma display inverted measure and find the center of the plasma display. Measure from the top of the base plate to the center of the PP-SPA and lock the height by  
tightening the two (2) M8 socket head screws (supplied) to the poles.  
Plasma  
Measuring tape  
Measuring tape  
Allen wrench  
PP-SPA  
Adapter  
Base plate  
Suitable surface  
(see warning)  
Installing the wall plates  
Step 4  
CAUTION: The plasma display is vary heavy two people are required to lift the plasma and secure it to the stand.  
The flowing diagrams show the CTM and PCM series systems.  
PSM-Series: Raise the plasma display with the mounting bracket secured to the plasma display and insert the four (4) tab openings from the PSM mount to the four (4) receiving tabs  
found on the PDB-UWFB back plate slide the plasma down, right and down again to lock the mounts together. Make sure all tab openings are interlocked with the receiving tabs before  
letting go of the plasma. Secure the brackets with the two (2) M6 x 12 (mm) Phillip screws (supplied).  
CTM-Series: Raise the plasma display with the left and right brackets secured to the plasma and insert the bottom and top hooks from the mounting arms to the top and bottom rods found  
on the CTM back plate. Secure the mounting arms with the two (2) M6 x 12 Safety knobs (supplied).  
CAUTION: The safety knobs MUST be used failure to do so may result in damage to the plasma or personal injury. See fig 4,5,6.  
PP-SPA  
Adapter  
PP-SPA  
Adapter  
M10 bolts & flat  
M10 bolts & flat  
washers  
washers  
CTM  
Back plate  
PDB-UWFB  
Back plate  
- 6 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PSM  
EXAMPLE PLASMA FOR ILLUSTRATION PURPOSES  
Series  
PDB-UWFB  
Back plate  
1
B
Plasma  
Mount  
interlocking  
2
A
3
Receiving  
(4) Tabs  
(4) Tabs  
openings  
CAUTION: The mounts must have  
all four (4) tabs engaged and  
properly interlocked.  
Plasma mounting  
bracket  
CAUTION: The plasma display is  
vary heavy two people are  
required to lift the plasma and  
(2) M6 x 12  
Phillip screws  
Plasma  
secure it to the stand.  
C
CAUTION: Secure the two (2) M6 x 12  
Phillip screws to secure both brackets.  
Plasma mounting  
bracket  
PP-SPA  
Adapter  
PDB-UWFB  
Back plate  
CTM  
Series  
EXAMPLE PLASMA FOR ILLUSTRATION PURPOSES ONLY  
(2) M6 x 12  
Safety knobs  
2
1
Plasma  
CTM  
Back plate  
Mounting  
brackets  
Thank you for choosing PREMIER MOUNTS for your installation needs.  
If you have any questions please contact PREMIER MOUNTS information is  
shown on the front of this page.  
Note: Make sure to recheck all  
hardware for proper tightness  
and security.  
- 7 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Paxar Printer 9840CL User Manual
Pelco Home Security System C2493M User Manual
Pelco Switch MS504AFL User Manual
Philips Clock Radio ORD2105 User Manual
Philips Cordless Telephone CD5352S User Manual
Philips Flat Panel Television 19PFL3403D 27E User Manual
Philips Work Light ED 37 User Manual
Poulan Blower 545137216 User Manual
Powermatic Lathe 3520A User Manual
Powerware Power Supply Model V 2000B User Manual