Premier Heat Pump PHP HWC 150 User Manual

Premier Heat Pumps  
Water Heater & Chiller User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Content  
ESSENTIAL NOTES ON ACCEPTANCE AND INSTALLATION OF THE  
PREMIER HEAT PUMPS (PHP) WATER HEATER AND CHILLER  
2
3
4
5
Content  
1 - Warnings and Cautions  
! Caution !  
2 - Description of the Heat Pump  
2-1 Outside  
6
6
7
8
2-2 Inside  
2-3 Dimensional and Technical Characteristics  
3 - Installation  
9
9
3-1 Locating the Unit  
Caution  
9
3-2 Water connections  
10  
11  
12  
13  
3-3 Electrical Connections  
3-4 How the reversible heat pump operates  
3-5 Display and Control Screen Description  
4 - Use in Standard Mode  
14  
5 - Instructions for the Installer  
5-1 Unit controller and parameters  
5-2 Defrost operation:  
16  
16  
16  
17  
5-3 Fault Codes and Fault Descriptions  
6 - Maintenance Instructions  
7 - Gas Flow Diagram  
17  
18  
20  
21  
8 - Wiring Diagram  
9 - Problems and Solutions  
Page 3  
Premier Heat Pumps – Water Heater and Chiller Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1 - Warnings and Cautions  
Incorrect handling has the potential to cause serious damage or injury to  
the unit, installer or operator. The unit should be installed by a  
professional and operated in accordance with this user manual  
Do not  
Attention  
Confirm electrical connection  
Disconnect power supply  
Do not stand on or place objects on the unit  
Do Not Touch  
Unit must be installed in accordance with AS/NZS 3500.4 : NZBC G12  
Complies with CE and New Zealand Safety Standards including; AS/NZS 60335  
AS/NZS 4692 : AS/NZ 2712  
Specifications may be amended from time to time without prior notice.  
Page 4  
Premier Heat Pumps – Water Heater and Chiller Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
! Caution !  
Do not climb on the unit or try to move Keep out of reach of children. Do not  
it once installed.  
allow them to play on or near the unit.  
Do not place foreign objects or fingers Important: Ensure that the plug remains  
into the air inlet/outlet. The fan runs at clean, free from moisture, foreign objects  
high speed and can cause serious  
and dirt. Ensure that the plug is properly  
injury. Do not operate the unit without inserted or hard wired by a qualified  
the safety grill in place.  
electrician.  
If the unit operates abnormally, stop  
the unit by firstly switching it off and  
then unplug the unit. For example, if  
there is a strange smell or abnormal  
noise coming from the unit.  
Do not clean the appliance with water.  
Water will go into the unit and will destroy  
the insulation.  
Turn the unit off at the wall before  
Do not pull on the cable to unplug the  
unplugging the unit. Do not disconnect unit, damage to the plug and cable could  
the power while the unit is running.  
occur  
Ensure that the power to the heat pump is  
Do not touch the plug with wet hands, disconnected before removing leaves,  
as electric shock can occur.  
particles or other foreign objects from the  
air inlet vanes.  
Verify the network specifications, with the unit data recorded on the heat pump  
prior to installation.  
Any additional disinfectant systems, such as chemical or electrolysis are not  
recommended for use with this hot water heat pump. The pump MUST be installed  
prior to these systems.  
For optimal operation of the heat pump, the following maximum values apply:  
A. Use of free chlorine : max : 2.6mg/l  
B. Total bromine : max : 5.6mg/l  
C. pH : between 6.5 and 8.0  
Page 5  
Premier Heat Pumps – Water Heater and Chiller Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2 - Description of the Heat Pump  
2-1 Outside  
1
2
3
4
5
6
7
8
Power Plug  
Control Panel  
Air Inlet  
Air Outlet  
Temperature Sensor  
Drainage  
Cold Water Inlet  
Hot Water Outlet  
Page 6  
Premier Heat Pumps – Water Heater and Chiller Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2-2 Inside  
1
2
3
4
5
6
7
8
9
Control Panel Cover  
15 Four-way Valve 2  
16 Gas Returning Pipe  
17 Exhaust Pipe  
18 Filter  
29 Top Cover Plate  
Control Panel  
30 Air Inlet Frame  
Power Plug  
31 Clip of Power Cable  
Plastic Base  
32 Drainage Pipe  
Water Tank  
19 Heat Exchanger Heater  
20 Auxiliary Capillary  
21 Capillary  
33  
34  
35  
36  
37  
38  
39  
40  
41  
42  
Cover for Electrical Box  
Motor Capacitor  
Compressor Capacitor  
Temperature Sensor  
22 Defrost Sensor  
23 Condenser Top Poly-foam  
24 Heat Exchanger  
25 Fan  
10 Circuit Board  
11 Electrical Box  
12 Compressor Heater  
13 Compressor  
26 Fan Motor  
27 Motor Bracket  
28 Rear Net  
14 Four-way Valve 1  
Page 7  
Premier Heat Pumps – Water Heater and Chiller Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2-3 Dimensional and Technical Characteristics  
Model Number  
PHP HWC-150  
PHP HWC-200  
PHP HWC-260  
Heating Capacity (KW)  
Cooling Capacity (KW)  
3.2  
2.6  
5.8  
4.9  
1.48  
6.8  
8.4  
1
6.5  
5.7  
1.8  
8.4  
12.6  
1
Nominal Power Input (KW) 0.9  
Nominal Current (A)  
Maximum Current (A)  
Compressor Quantity  
Fan Quantity  
4.2  
6.3  
1
1
1
1
Noise dB(A)  
47  
47  
49  
Temperature of output  
water (°C)  
10-55  
10-55  
10-55  
Unit Net Dimension (D X H)  
Φ470 X 1965  
555/530/2085  
Φ555X 1780  
630/610/1900  
Φ555X 2113  
630/610/2233  
Unit Shipping Dimension  
(L/W/H)  
Net weight / Gross weight  
(kg)  
46/49  
1
56/60  
1
70/74  
1
Water Connection (Inch)  
Capacity of the water tank  
(L)  
150  
200  
260  
Power Supply (V/Ph/Hz)  
Ambient Temperature ()  
Electrical Control Way  
Controller  
220-240/1/50  
-7 to +40  
220-240/1/50  
-7 to +40  
220-240/1/50  
-7 to +40  
Mini Computer Intelligent Control  
LCD Display  
Yes  
Wire Control  
Heating and Cooling Water Yes  
Auto-defrosting Function  
Yes  
Maximum input water  
pressure  
1550 kpa  
* According to climactic conditions  
NB: Product sound measurement is tested in the factory before shipping.  
“Dimensions and Technical Characteristics” data table shown above is accurate  
at the time of publication. Premier Heat Pumps reserves the right to amend the  
unit specifications without prior notice. Product code plate affixed to the  
individual unit reflects the specifications of the individual unit.  
Page 8  
Premier Heat Pumps – Water Heater and Chiller Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3 - Installation  
3-1 Locating the Unit  
It is important to install the hot water heat pump in accordance with the following  
instructions. Water and electrical connections must be carried out by a suitably  
qualified tradesman or installer  
The appliance must be installed outside.  
The appliance must be mounted on its anti-vibratory studs, positioned on  
a substantial platform (concrete or steel pad). The platform must have  
sufficient height to prevent water entering the bottom of the unit and also  
allow the condensate to drain freely from the connection at the bottom of  
the unit  
Vegetation and other obstacles must be kept clear of the unit, in  
accordance with the minimum distances detailed below  
The unit should be positioned so that the exhaust does not blow towards  
windows or doorways.  
There must be a minimum clear distance above the unit of 1.5m  
The stability bracket on the back of unit must be securely fixed to a post  
or wall so as to position the unit vertically and prevent any movement of  
the unit.  
Connect the drain pipe to the condensate outlet and direct it away from  
the unit.  
Caution  
Do not install the appliance in an area where dirt, mud, mown grass or  
other foreign objects could affect airflow around the unit causing damage  
or operational issues.  
Shelter the unit from prevailing winds  
Shelter the unit from falls of snow or heavy rain fall  
Prevent children from playing on or around the unit  
Page 9  
Premier Heat Pumps – Water Heater and Chiller Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3-2 Water connections  
Please refer to the diagram below:  
1) Connect the hot water in pipe (hot water supply pipe) to the outlet port on the  
hot water cylinder. Pay attention to heat preservation and ensure appropriate  
thermal insulation of the pipe work. It is important that the unused hot water  
outlet port be properly capped. The plastic transport caps are not suitable for  
this function.  
2) Install a water filter (where necessary) and one-way valve in the tap water (  
inlet water pipe) and then connect the tap water pipe (inlet water pipe) to the  
inlet port on the tank.  
3) Fill the tank with water. Open the tap water (inlet water) in-valve allowing the  
tank to fill with water; Meanwhile, open the hot water out-valve, until the water  
spills over from the hot water out valve. Once this happens the tank is full of  
water. Close the tap water (inlet water) in-valve, check and ensure that there  
is no leakage in the system. Re open all valves.  
Attention: Be sure the tank is full of water before it is switched on.  
Warning: The inlet and outlet plastic caps are for transport only. Any  
unused inlet or outlet ports must be blanked off properly using compliant  
metal pipe caps.  
Page 10  
Premier Heat Pumps – Water Heater and Chiller Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3-3 Electrical Connections  
CAUTION: before connecting the appliance, make sure that the supply  
power line is disconnected from the network.  
General Power Supply Characteristics  
Neutral mode TT and TN.S; the circuit of the heat pump must be  
connected to the earth circuit  
Connections  
The electric installation must be carried out by a qualified professional or  
electrician  
The power supply of the heat pump must come from an independent  
circuit and have the appropriate circuit protection.  
The controller must be installed on an indoor wall in an easily accessible  
area.  
Electrical Protection  
Circuit breaker curves D or standard fuse protection Am, gauged with  
16A  
Differential protection of 30mA  
Connection to an Electrical Plug  
The heat pump comes packaged with an electric cable and plug.  
The plug must be safe, protected from rain and water and the condition  
checked regularly  
Before starting the heat pump hot water cylinder, it is important to fully read this  
manual and understand the operation and the settings.  
Page 11  
Premier Heat Pumps – Water Heater and Chiller Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3-4 How the reversible heat pump operates  
By using the free energy contained in the ambient air, the heat pump enables  
the heating of the water in a very economical way. Your heat pump is a heat  
machine that can transfer the heat from a low temperature area (ambient air) to  
a higher temperature area.  
How the pump operates in heating mode:  
The heat of the air is absorbed by the cold, liquid refrigerant, through the  
evaporator (radiator with wings), the refrigerant is vaporised. Then the  
compressor increases the pressure and the temperature, and sends it into the  
condenser (exchanger) where it loses its heat by transferring it to the water. The  
refrigerant then returns to the liquid state, it loses its pressure and cools again,  
flowing into the pressure reducer before returning to the evaporator for a new  
cycle.  
Operating cooling mode or defrosting mode:  
A 4 way valve enables a reverse cycle of the refrigerant; this fluid liquid is  
vaporized in the exchanger (the evaporator) by taking the heat out of the water,  
which then passes into the compressor that heats it and in turn sends it to the  
radiator (the condenser) where the refrigerant returns to it's liquid state.  
Note: Single water heater without cooling water mode; Single water chiller  
without heating water mode and defrosting mode.  
Page 12  
Premier Heat Pumps – Water Heater and Chiller Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3-5 Display and Control Screen Description  
Page 13  
Premier Heat Pumps – Water Heater and Chiller Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4 - Use in Standard Mode  
Starting operation  
Press the power button  
when the unit has received the signal it gives out  
two 'beep' tones. The operation light switches on and the heat pump water  
heater starts operation. The compressor will restart after 3 minutes to protect  
the system if the interval is shorter than 3 minutes from the last shut down to the  
present switch on.  
Mode Selection  
Press the 'M' button to chose the mode of heating and cooling (this key is  
invalid for the single water chiller or single water heater)  
Temperature Setting Selection  
1) Press "Temperature Adjustment Button  
degree higher  
to set the temperature 1  
to set the temperature 1  
2) Press "Temperature Adjustment Button  
degree higher  
3) Temperature range is set in heating mode: 45°C to + 55°C (Single water  
chiller is without this function)  
4) Temperature range is set in cooling mode: 10°C to + 35°C (Single water  
heater is without this function)  
Timer Switch On  
1) When the heater is off press the  
timer-on button to set time for the  
timer-on switch. Press the button once to change the time interval of 1  
hour in a cyclic manner of 1,2,...24,1,2 (The display shows the previous  
time as the starting time of the present setting)  
2) When it reaches the switch-on time, the heat pump water heater will  
operate in the preset time mode.  
3) Press the timer-on  
4) If the on/off  
button again, and the set up is cancelled.  
button is pressed while the unit is under the timer on  
setting, the unit will start immediately. The timer setting is at that point  
cancelled.  
Timer-Off Switch  
1) When the heater is on, press the  
timer-on button to set time for the  
timer-on switch. Press the button once to change the time interval of 1  
hour in a cyclic manner of 1,2,...24,1,2 (The display shows the previous  
time as the starting time of the present setting)  
Page 14  
Premier Heat Pumps – Water Heater and Chiller Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2) When it reaches the switch-off time, the heat pump water heater will  
automatically shut down.  
3) Press the timer-on  
4) If the on/off  
button again, and the set up is cancelled.  
button is pressed while the unit is under the timer-off  
setting, the unit will shut down immediately. The timer setting is  
cancelled.  
5) Timer-On and Timer-Off cannot be set at the same time.  
Coercive Defrosting  
1) Press the  
button, the heater will go into the defrost mode.  
2) After 3 minutes, when the units coil temperature has reached 10°C or the  
time of defrost reaches 8 minutes, defrosting is stopped.  
3) After exiting the defrost mode, the heater will stop operation for 3  
minutes, then it will run in the mode before defrosting. (This key is invalid  
for single mode water chiller)  
Page 15  
Premier Heat Pumps – Water Heater and Chiller Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5 - Instructions for the Installer  
The installer must read the following and provide instructions to the purchaser.  
5-1 Unit controller and parameters  
The Heat Pump is Equipped with 2 Control Devices:  
A defrost temperature probe, located on the evaporator, starts the defrost  
sequence.  
A thermal probe located on the exchanger ensures the cut of the heat  
pump when the temperature of the water reaches the temperature  
required.  
The meaning of the code name  
T1: water temperature  
T2: ambient temperature  
T3: exhaust temperature from compressor  
T4: coil temperature in outdoor heat exchanger  
TC: water temperature setting  
Control Function:  
1) TC can be set between 10C-35°C in cooling mode. Original TC is 18°C.  
When T1T°C -1°C, Compressor and fan motor stop; When T1T°C  
+1°C, Compressor and fan motor start.  
2) TC can be set between 45°C -60°C in heating mode. Original TC is  
50°C. When T1TC-1C, Compressor and fan motor start; When  
T1TC+1C, Compressor and fan motor stop. When compressor is  
running, if T212°C, the four way valve2 on; if T212°C, the four way  
valve2 off.  
5-2 Defrost operation:  
1) Defrost:  
The system begins to defrost if the following three terms are met in the  
same time:  
a) T4-5°C lasts for a while;  
b) compressor runs continuously for more than 5 minutes  
c) Compressor runs accumulative total for 45 minutes  
While the system begins to defrost, compressor and fan motor stop first and  
four way valve1 is on after 1 minute and begins to work. The compressor  
restarts after it has stopped for 3 minutes. If the sensor for T4 is damaged, the  
system begins to defrost, after the compressor has run continuously for 45  
Page 16  
Premier Heat Pumps – Water Heater and Chiller Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
minutes.  
2) Parameters for Exiting Defrost Mode:  
When defrosting time reach 3 minutes and T4 reaches 10°C or defrosting  
time reaches 8 minutes, defrost exits and starts heating water mode.  
While defrost is exiting, after compressor and fan motor have stopped for  
1 minute, the four way valve1 is turned off.  
The Compressor will restart after it stops for 3 minutes, and the system  
will run the same mode as before defrosting.  
5-3 Fault Codes and Fault Descriptions  
Failure Code:  
E1: sensor for T1 (water temperature) failure  
E2: sensor for T2 (ambient temperature) failure  
E3: sensor for T3 (exhaust temperature from compressor) failure  
E4: sensor for T4 (coil temperature in condenser) failure  
E5: Compressor stops three times in 24 hours because the current is too high.  
E6: While heating water, there is three times of T3100°C in 24 hours.  
E7: There is electrical leakage in the compressor or outdoor motor or four-way  
valve  
Recommendation: Contact the installer or service agent  
6 - Maintenance Instructions  
The following operational maintenance must be done by a qualified person each  
year:  
Clean the back evaporator with a delicate brush and water jet without  
any pressure (karcher prohibited)  
Check the mandatory labelling and the operation of the unit  
Check the safety measures  
Check the pressure of the refrigerating gas  
Clean the electric box and control the connections  
Check the electrical connections  
Page 17  
Premier Heat Pumps – Water Heater and Chiller Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7 - Gas Flow Diagram  
Page 18  
Premier Heat Pumps – Water Heater and Chiller Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Page 19  
Premier Heat Pumps – Water Heater and Chiller Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8 - Wiring Diagram  
Page 20  
Premier Heat Pumps – Water Heater and Chiller Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
9 - Problems and Solutions  
Please refer to the table below for the most common problems. These can often  
be solved by reading the table below. If nothing corresponds to the list, or if the  
solutions applied do not solve the problem, contact your retailer  
Problem  
Observation  
Probable Cause  
Explanation/Solution  
Check the plug and  
electrical connection.  
Check the line circuit  
breaker  
The heat pump does  
not start  
No electrical feed or  
power supply  
Blank display  
The heat pump does  
not start  
Find out reason and  
repair  
Screen on  
Low voltage  
Check leakage, charge  
refrigerant with correct  
amount.  
Change compressor  
repair damaged  
The heat pump starts  
and stops within a  
few minutes  
Refrigerant circuit is  
damaged  
refrigerant circuit  
Water temperature and  
ambient temperature too  
low Water amount used  
continuously too large.  
The temperature of  
the water heater  
increases very slowly  
The heat pump works  
The condensates are  
formed in humid  
Attach the plastic  
conduit to the black  
plastic outlet and direct  
the water away from  
the unit  
Water condensate come  
from the condenser and  
is part of normal  
Water is running  
under  
the heat pump  
conditions on the cooling  
fins of the evaporator.  
Install the conduit to  
direct the water away  
from the machine  
operation  
The frost is entailed by  
the freezing of the  
humid air on the wings  
of the evaporator. It's  
quite natural and the  
heat pump is going to  
defrost. Consider the  
wintering of the heat  
pump.  
Ambient temperature is  
too low  
The thickness of the  
frost is thin  
Some frost appears  
outside, on the wings  
of the evaporator  
The thickness of the  
frost is thick (the  
blades of the ventilator  
may rub on the ice  
much more on the  
inside)  
The de-icing probe or  
the thermic circuit  
breaker does not work  
Stop the heat pump and  
call your retailer  
The pressure of the  
refrigerant shown on  
the manometer is very  
low  
Loss of refrigerant from  
the unit  
The heat pump  
works but the  
temperature of the  
water does not rise  
(*)  
Stop the heat pump and  
call your retailer or a  
refrigeration technician  
The pressure of the  
manometer  
is right  
Breakdown or abnormal  
wear of the compressor  
Page 21  
Premier Heat Pumps – Water Heater and Chiller Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Peavey Music Mixer XRD 680 PLUS User Manual
Philips DVD VCR Combo DVDR3512V 12 User Manual
Philips TV Mount SQM4122 User Manual
Pioneer Car Stereo System DEH P3110 User Manual
Pioneer Headphones SE NC31C K User Manual
Polk Audio Speaker 110B User Manual
Polycom Network Hardware 6400 S User Manual
Polycom Video Gaming Accessories 3725 74600 004 User Manual
Powermate Portable Generator PM0421100 User Manual
Printek All in One Printer 8000SE User Manual