Features  
• Guaranteed low oil carryover rate of  
less than 2 PPM  
• Three year warranty on compressor  
pump  
• Isolation pads  
• Optional R134 dryer  
• ASME tank  
• UL listed controls  
Figure 1 - AS-XXX 1 Hp Simplex Air Compressor  
The AS-XXX Series Powerex Simplex Air  
Compressors have been designed, bro-  
ken-in and tested to meet the most  
Specifications  
Product  
AS-XXX Series Powerex Simplex Air Compressors  
demanding specifications in the pneu-  
matic climate control industry for low  
oil carryover and long life.  
Performance  
Specifications  
Models & Options  
Lubrication  
Operating  
See Table 1  
See Table 2  
All Powerex air compressors have reli-  
able operation and feature high quality  
construction and components. An  
unloading feature is included on all  
compressors to provide loadless start-  
ing. Oil entrainment is minimized by  
the use of lap joint piston rings, low  
compressor speeds and a special lubri-  
cating oil with a high flash point and  
low carbon content.  
1/2 Through 10 Splash Lubrication System  
1Ø  
115 - 208/230 Volts, 60 Hz  
208-230/460 Volts, 60 Hz  
Voltages  
3Ø  
Compression  
Cycle  
1/2 Through  
10 Hp Models  
1Ø  
Single-Stage  
Motor Overload  
Protection  
Built-In Thermal Overload (Standard)  
Magnetic Starter and Three Thermal Overload  
Switches (Optional)  
3Ø  
Pressure Settings  
Cut-In: Factory Set at Approximately 70 psig (490kPa)  
Cut-out: Factory Set at Approximately 90 psig (630 kPa)  
ASME Safety Valve Factory Set and Sealed at  
Approximately 115 psig (805 kPa)  
1/2" NPT on 30, 60 and 80 Gallon Tanks;  
1" NPT on 120 and 200 Gallon Tanks  
See Table 2  
Overpressure  
Protection  
Outlet Air  
Connections  
Tank Sizes  
California  
All 1/2 through 10 hp models are also  
equipped with an auxiliary cooling fan  
and air control shroud to achieve low  
head temperatures and further mini-  
mize oil carryover.  
Powerex compressor motors are NEMA  
Class B design. Single-phase motors  
have built-in overload protection and a  
DPST disconnect switch. Three-phase  
motors require a manual or magnetic  
starter and three overload heater coils  
which may be ordered as a factory  
mounted and wired option.  
Ordinance 462  
(L) (2)  
Meets Requirements of this Ordinance  
Tank Isolation  
Manuals  
Standard All Units  
200 Page Service Manual Available  
The performance specifications are nominal and conform to acceptable industry standards. For applica-  
tion at conditions beyond these specifications, consult the local Powerex office. Powerex shall not be  
liable for damages resulting from misapplication or misuse of its products.  
Powerex • 150 Production Drive • Harrison, OH 45030 • USA  
IN259601AV 10/04  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Climate Control Simplex  
AUTO E-DRAIN ASSEMBLY (See  
Figure 3)  
NOTE: The automatic E-drain is assem-  
bled to tank.  
1. Plug E-drain into 115V power outlet  
supply.  
2. Adjust times accordingly.  
Manifold  
Assembly  
ON  
4
TEST  
OFF  
30  
6
20  
2
8
10  
5
40  
0.5  
10  
0.5  
45  
sec.  
min.  
Figure 3 - Auto E-Drain  
TABLE 2: MODEL NUMBER  
AS  
OR  
Tank Drain/Dryer Options  
Motor Horsepower, Voltage Phase  
Tank Size  
1Ø  
Horsepower  
3Ø  
(Gallons)  
Available on:  
Manual Drain,  
No Dryer = 1  
E-Drain,  
105 =  
107 =  
110 =  
NA =  
NA =  
NA =  
NA =  
NA =  
NA =  
1/2  
3/4  
1
= 005  
= 007  
= 010  
= 015  
= 020  
= 030  
= 050  
= 075  
= 100  
30 = 1  
60 = 2  
80 = 3  
120 = 4  
200 = 5  
1/2 Through 112 Hp  
3/4 Through 2 Hp  
2 Through 712 Hp  
5 Through 10 Hp  
712 and 10 Hp  
No Dryer = 2  
Manual Drain,  
}
with Dryer = 3  
E-Drain,  
with Dryer = 4  
11⁄  
2
2
3
5
Available on  
1/2 through 3 Hp  
models only.  
71⁄  
2
Starter Options  
None = 0  
10  
3Ø, 208V Starter* = 2  
3Ø, 208/230V Starter** = 3  
3Ø, 460V Starter = 4  
NA = Not Available  
1Ø, 115V Starter = 5  
Example 1: To order a Simplex air compressor with a  
3/4 Hp single-phase motor, 60 gallon tank, single-  
phase 115 volt starter, automatic tank drain and an  
air dryer, use product code AS-107-254.  
1 Ø, 208/230 V Starter = 6  
1Ø vs 3 Ø selection must agree with  
base model selection.  
Example 2: To order a Simplex air compressor with a  
10 Hp three-phase motor, 200 gallon tank and an  
auto drain, use product code AS-100-502.  
**This starter selection is dual  
rated. Choosing digit “3”  
means 230 V.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Climate Control Simplex  
* With  
Integral  
Overload  
*Comp.  
Motor  
m
Secondary  
Thermal  
Overloads  
N.C.  
Pressure  
Switch  
Starter  
m
m
Manual  
Disconnect  
Switch  
Figure 4 - AS-XXX Single-Phase Wiring  
With Pressure Switch Used for Pilot Duty  
1Ø 230 VAC  
Manual  
N.C.  
Disconnect  
Switch  
Pressure  
Switch  
1Ø  
Line  
Voltage  
* With  
Integral  
Overload  
*Comp.  
Motor  
Figure 5 - AS-XXX Single-Phase Wiring  
With Pressure Switch Used as Contactor  
Manual  
Disconnect  
Switch  
Thermal  
Overloads  
M
M
O.L.  
3Ø  
Line  
Voltage  
*Comp.  
Motor  
M
M
N.C.  
Pressure  
Switch  
Figure 6 - AS-XXX Three-Phase Wiring  
With Pressure Switch Used for Pilot Duty  
NOTE: “M” = Magnetic Contactor  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Climate Control Simplex  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Climate Control Simplex  
M
A
E
L
(Inside Belt Guard)  
F
(Inside Belt Guard)  
D
J
B
C
G
K
N
H
REPLACEMENT PARTS LIST  
Shipping  
Weight  
(lbs.)  
Quantity  
Required  
Code  
Number  
Item  
Description  
A
PUMP AND FLYWHEEL:  
Motor Hp  
1/2, 3/4  
1
1
1
1
1
1
1
19.5  
35  
A-005-6001  
1, 11⁄  
2
A-010-6001NP  
A-020-6001NP  
A-030-6001NP  
A-050-6001NP  
A-075-6001NP  
A-100-6001NP  
2
3
5
59  
66  
115  
121  
180  
71⁄  
2
10  
B
C
D
E
VALVE KIT: Includes valve plate, spacer and head gasket  
Motor Hp  
1/2  
3/4  
1
1
1
2
2
2
2
3
0.4  
0.4  
0.5  
0.5  
0.7  
1.2  
1.2  
1.2  
A-005-6002  
A-005-6002  
1, 11⁄  
2
A-010-6002NP  
A-010-6002NP  
A-030-6002NP  
A-050-6002NP  
A-075-6002NP  
A-075-6002NP  
2
3
5
71⁄  
2
10  
RING/CYLINDER KIT: Includes all compression rings, oil control rings, cylinder, gasket and sealant  
Motor Hp  
1/2  
3/4  
1
1
1
2
2
2
2
3
3.6  
3.6  
4.8  
4.8  
5.5  
10  
A-005-6004  
A-005-6004  
1, 11⁄  
2
A-010-6004NP  
A-010-6004NP  
A-030-6004NP  
A-050-6004NP  
A-075-6004NP  
A-075-6004NP  
2
3
5
71⁄  
2
10  
10  
10  
INTAKE FILTER ELEMENT:  
Motor Hp  
1/2  
3/4  
1
1
1
1
1
2
2
3
0.1  
0.1  
0.2  
0.2  
0.2  
0.2  
0.2  
0.2  
A-005-6023  
A-005-6023  
1, 11⁄  
2
A-010-6023NP  
A-030-6023NP  
A-030-6023NP  
A-030-6023NP  
A-030-6023NP  
A-030-6023NP  
2
3
5
71⁄  
2
10  
BELT:  
Motor Hp  
Size  
1/2  
3/4  
1
AX-42  
1
1
1
1
1
1
2
2
2
2
0.3  
0.3  
0.3  
0.3  
0.4  
0.4  
1.6  
2.0  
2.0  
2.4  
A-005-6006  
AX-42  
A-005-6006  
A-43  
A-010-6006  
11⁄  
2
A-46  
A-015-6006NP  
A-020-6006NP  
A-030-6006NP  
A-050-6006NP  
A-075-6046NP  
A-075-6056NP  
A-100-6006NP  
2
3
5
A-65  
A-62  
A-65  
71⁄  
2
(120 gal tank) A-67  
(200 gal tank) A-75  
A-84  
71⁄  
10  
2
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Climate Control Simplex  
REPLACEMENT PARTS LIST (Continued)  
Shipping  
Weight  
(lbs.)  
Quantity  
Required  
Code  
Number  
Item  
Description  
F
MOTOR PULLEY:  
Motor Hp  
1/2  
Type  
1A-4.4” P.D., 5/8” Bore  
1A-5.8” P.D., 5/8” Bore  
1A-4.0” P.D., 5/8” Bore  
1A-4.0” P.D., 7/8” Bore  
1A-6.0” P.D., 7/8” Bore  
1A-6.0” P.D., 7/8” Bore  
1A-6.0” P.D., 118” Bore  
2A-5.6” P.D., 118” Bore  
2A-7.6” P.D., 138” Bore  
2A-7.6” P.D., 158” Bore  
1
1
1
1
1
1
1
1
1
1
3.8  
3.9  
A-005-6007  
A-007-6037  
A-110-6007  
A-010-6007  
A-020-6007  
A-020-6007  
A-030-6007NP  
A-050-6007NP  
A-075-6007NP  
A-100-6007NP  
3/4  
1 (1 Ø)  
3.2  
1 (3 Ø)  
3.2  
11⁄  
2
5.6  
2
3
5
5.2  
6.3  
7.6  
71⁄  
2
12.5  
13.5  
10  
G
IN-TANK CHECK VALVE:  
Motor Hp  
Size  
1/2 Through 3  
1/2” MPT x 1/2” FPT  
3/4” MPT x 3/4” FPT  
1
1
0.3  
0.4  
A-010-6008  
A-075-6008  
5 Through 10  
H
J
SAFETY RELIEF VALVE: Set at approximately 115 psig (805 kPa)  
1/2 Through 5 Hp Models  
1
1
0.1  
0.2  
A-050-6009  
A-200-6009  
71⁄  
Through 10 Hp Models  
2
PRESSURE ELECTRIC SWITCHES: (For all models)  
Lead Switch: Set at approximately  
70 psig (490 kPa) cut-in and  
90 psig (630 kPa) cut-out  
1
1
0.9  
0.9  
A-100-6010  
A-100-6011  
Lag Switch: Set at approximately  
60 psig (420 kPa) cut-in and  
80 psig (560kPa) cut-out  
K
TANK:  
Motor Hp  
Tank Size  
30 gallon  
60 gallon  
60 gallon  
80 gallon  
80 gallon  
120 gallon  
120 gallon  
200 gallon  
1/2 Through 11⁄  
2
1
1
1
1
1
1
1
1
134.0  
175.0  
184.0  
235.0  
243.0  
398.0  
415.0  
677.0  
A-010-6030NP**  
A-010-6060NP  
1/2 Through 11⁄  
2 & 3  
2
A-020-6060NP  
1/2 Through 11⁄  
2 & 3  
2
A-010-6080NP**  
A-020-6080NP**  
A-020-6120NP**  
A-050-6120NP**  
A-100-6200NP**  
2 & 3  
5 & 71⁄  
2
5 Through 10  
L
COOLING SHROUD:  
Motor Hp  
1/2  
3/4  
2
1
1
1
1
1
1
1
1.0  
1.0  
1.7  
1.7  
1.9  
1.9  
4.5  
A-005-6013  
A-005-6013  
A-020-6013NP  
A-030-6013NP  
A-050-6013NP  
A-075-6013NP  
A-100-6013NP  
3
5
71⁄  
2
10  
M
N
BELT GUARD:  
Motor Hp  
1/2 Through 11⁄  
2
1
1
1
1
2.4  
12.5  
12.5  
18.5  
A-010-6012  
A-020-6012  
A-050-6012  
A-100-6012  
2 & 3  
5 & 71⁄  
10  
2
LIQUID GASKET:  
Motor Hp  
1/2 Through 10  
1
0.1  
A-999-6000  
**This replacement tank is also the replacement tank used on duplex air compressors and will include mounting hardware for a second pump.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Climate Control Simplex  
Maintenance Schedule  
Operating Hours  
Item  
Action needed  
500  
2500  
5000  
10,000  
15,000  
20,000  
Remarks  
Tank  
Inlet air filter  
Blower fan  
Drain moisture  
Replace  
Clean  
Daily  
G
2500  
L
(Every 2,500 hrs or less)  
G
G
G
G
G
G
Fan duct  
Clean  
G
G
Compressor fins  
Oil change  
Clean  
Replace  
G
(Every 2,500 hrs or less)  
(Every 1,500 hrs)  
Compression rings  
Check oil  
Piston set  
Replace  
Inspect  
Replace  
L
Daily  
G
V-belt  
Pressure switch  
Inspect, replace  
Confirm operation  
*Note 3  
G
L
L
G
L
L
G
Magnetic starter  
Inspect  
G
G
Replace if contact  
points deteriorated  
Safety valve  
Pressure gauge  
Confirm operation  
Inspect  
G
G
(Every 2,500 hrs or less)  
(Every 2,500 hrs or less)  
(G) Inspect  
(L) Replace  
NOTES:  
1. Inspect and perform maintenance periodically according to maintenance schedule.  
2. The maintenance schedule relates to the normal operating conditions. If the circumstances and load condition are adverse, shorten the  
cycle time and do maintenance accordingly.  
3. * The tension of the V-belt should be adjusted during initial start up and inspected every 1,500 hours afterwards. Proper belt tension for  
1/2 to 3 HP units is 2-3 lbs./.5” deflection; for 5 to 10 Hp units, 4-6 lbs./.5” deflection.  
Powerex Limited Warranty  
Powerex 3 Year / 10,000 Hour Extended Parts Limited Warranty - Powerex warrants each Compressor Pump or Scroll Air-End  
against defects in material or workmanship from the date of purchase for a period of Three years or 10,000 hours, whichever may  
occur first. This warranty applies to the exchange of part(s) of the compressor pump or air-end found to be defective by an Authorized  
Powerex Service Center.  
Powerex 1 Year / 5,000 Hour Inlet to Outlet Limited Warranty - Powerex warrants each Compressor Unit, System, Pump, or Air-  
End against defects in material or workmanship from the date of purchase for a period of One Year or 5,000 Hours, whichever may  
occur first. This warranty applies to the exchange of defective component part(s) and labor performed by an Authorized Powerex  
Service Center.  
The above mentioned warranty applies to POWEREX manufactured units or systems only.  
Items listed in the operator’s manual under routine maintenance are not covered by  
this or any other warranty.  
THERE IS NO OTHER EXPRESS WARRANTY. IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PAR-  
TICULAR PURPOSE, ARE LIMITED TO ONE YEAR FROM THE DATE OF PURCHASE: AND TO THE EXTENT PERMITTED BY LAW, ANY AND  
ALL IMPLIED WARRANTIES ARE EXCLUDED. THIS IS THE EXCLUSIVE REMEDY AND LIABILITY FOR CONSEQUENTIAL DAMAGES UNDER  
ANY AND ALL WARRANTIES IS EXCLUDED TO THE EXTENT EXCLUSION IS PERMITTED BY LAW.  
All claims pertaining to the merchandise in this schedule, with the exception of warranty claims, must be filed with POWEREX within 6  
months of the invoice date, or they will not be honored. Prices, discounts and terms are subject to change without notice or as stipulat-  
ed in specific product quotations. All agreements are contingent upon strikes, accidents, or other causes beyond our control. All ship-  
ments are carefully inspected and counted before leaving the factory. Please inspect carefully any receipt of merchandise noting any  
discrepancy or damage on the carrier’s freight bill at the time of delivery. Discrepancies or damage which obviously occurred in transit  
are the carrier’s responsibility and related claims should be made promptly directly to the carrier. Returned merchandise will not be  
accepted without prior written authorization by POWEREX and deductions from invoices for shortage or damage claims will not be  
allowed. UNLESS OTHERWISE AGREED TO IN WRITING, THESE TERMS AND CONDITIONS WILL CONTROL IN ANY TRANSACTION  
WITH POWEREX any different or conflicting terms as may appear on any order form now or later submitted by the buyer. All orders  
are subject to acceptance by POWEREX.  
150 Production Drive  
Harrison, OH 45030  
Phone: 1-888-769-7979  
Fax: 513-367-3125  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Climate Control Duplex  
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.  
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or  
property damage! Retain instructions for future reference.  
Features  
• Guaranteed low oil carryover rate of  
less than 2 PPM  
• Three year warranty on compressor  
pump  
• High efficiency motors  
• UL listed controls  
• R134A Air Dryer (Optional)  
The AD-XXX Series Powerex Duplex Air  
Compressors have been designed,  
broken-in and tested to meet the most  
demanding specifications for low oil  
carryover and long life in the  
pneumatic climate control industry.  
Figure 1 - AD-XXX Series 2 Hp Duplex Air Compressor  
with Optional Deluxe Alternator Package  
The units consist of two equally rated  
motor-compressor assemblies mounted  
on a single ASME tank. The compressor  
motors are NEMA Class B design. The  
AD-XXX Series Compressors are ideal for  
instrumentation systems requiring an  
alternate compressor for standby or  
overload capacity. See Table 1 for motor  
sizes and air delivery capacities available.  
Specifications  
Product  
AD-XXX Series Powerex Duplex Air Compressors  
Performance  
Specifications  
Models & Options  
Lubrication  
See Table 1  
See Table 2  
1/2 Through  
10 Hp Models  
1Ø  
Splash Lubrication System  
115/230 Volts, 60 Hz  
Operating  
Voltages  
Compressor assemblies are available with  
or without a factory mounted basic or  
deluxe alternator/motor starter package.  
An unloading feature is included on all  
compressors to provide loadless starting.  
Models with an alternator are prewired  
and ready for operation. Internal wiring  
allows for shutdown of either  
3Ø  
208-230/460 Volts, 60 Hz  
Compression  
Cycle  
1/2 Through  
10 Hp Models  
1Ø and 3Ø  
Single-Stage  
Motor Overload  
Protection  
Overloads (Supplied with all Factory Mounted  
Alternators; Otherwise Field Supplied)  
Cut-In: Factory Set at Approximately 70 psig (490kPa)  
Cut-Out: Factory Set at Approximately 90 psig (630 kPa)  
Cut-In: Factory Set at Approximately 60 psig (420kPa)  
Cut-Out: Factory Set at Approximately 80 psig (560 kPa)  
ASME Safety Valve Factory Set and Sealed at  
Approximately 115 psig (805 kPa)  
Lead  
Lag  
Pressure Switch  
Settings  
compressor for repair while the other  
compressor is running.  
Overpressure  
Protection  
An alternating type operation is  
desirable for many reasons. When a  
duplex air compressor is alternated, the  
temperature of both units is kept  
above the ambient dew point to  
minimize moisture deterioration and  
corrosion. Also, the reduction in on-  
time provides a lower average head  
temperature with reduced oil  
Outlet Air  
1/2" NPT on 30 and 80 Gallon Tanks;  
1" NPT on 120, and 200 Gallon Tanks  
See Table 2  
Connections  
Tank Sizes  
California  
Ordinance 462 (L)(2)  
Isolation Mounts  
Meets requirements of this Ordinance  
Vibration pads are included with each unit  
entrainment potential and improves  
the motor life by holding down the  
average heat rise.  
Powerex • 150 Production Drive • Harrison, OH 45030 • USA  
IN259702AV 3/05  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Climate Control Duplex  
TABLE 1: AD-XXX SERIES POWEREX DUPLEX AIR COMPRESSORS  
PERFORMANCE SPECIFICATIONS  
Base  
Actual Hp  
1Ø 3Ø  
Motor Rating  
Compressor  
RPM  
Compressor Capacity SCFM  
Model  
Hp  
RPM  
1725  
1720  
100% Runtime 50% Runtime 33% Runtime  
.54  
AD-105  
AD-005  
AD-107  
AD-007  
AD-110  
AD-010  
AD-015  
AD-020  
AD-030  
AD-050  
AD-075  
AD-100  
800  
1040  
625  
1.8  
2.5  
3.8  
0.9  
0.6  
.50  
.54  
.73  
.73  
1725  
1725  
1.25  
1.9  
0.83  
1.25  
.75  
1.07  
1.0  
1.5  
2.0  
3.0  
5.0  
7.5  
10.0  
1.07  
1.54  
2.0  
1750  
1750  
1745  
1745  
1745  
1750  
955  
800  
775  
690  
795  
685  
6.4  
8.6  
3.2  
4.3  
6.0  
2.11  
2.84  
4.0  
12.0  
22.0  
28.5  
43.0  
3.1  
11.0  
7.33  
9.44  
5.6  
14.3  
21.5  
8.2  
14.2  
10.3  
All units are run through a factory  
break-in and are tested for air delivery,  
leakage and power consumption. Units  
are shipped with a proper fill of  
compressor oil in the crankcase and are  
furnished with an intake filter/silencer  
with a replaceable cartridge. This  
filter/silencer combination is designed to  
remove contaminates in the inlet air, as  
well as provide quieter operation.  
BASIC ALTERNATOR PACKAGE  
Operation  
Refer to Installation Data AS/AD-XXX  
for detailed installation instructions.  
All Powerex duplex air compressors may  
be ordered with a simplified line voltage  
basic alternator package. The basic  
alternator package consists of an  
alternating coil and two magnetic motor  
starters. Motor starters are selected and  
wired for intended input voltage and are  
furnished with properly sized overload  
heaters. Refer to Table 2 for ordering  
details and figure 5 for wiring diagram.  
Factory calibrated DPST pressure switches  
provide lead and lag settings. When  
using an alternator-starter package, the  
lead switch energizes the alternator and  
the alternator activates the compressor  
that was on standby during the previous  
cycle. If the demand exceeds the  
capacity of one compressor, the lag  
switch will cause both compressors to run  
simultaneously. Upon failure of either  
compressor, the lag switch will continue  
to activate the workable compressor.  
All models have conveniently located  
oil drain and filler ports to facilitate  
routine maintenance. Tanks have a  
condensate drain valve with an  
extension for easy access. Mounting  
bases are slotted to allow tension  
adjustments to aid in maintaining  
proper compressor and motor  
REFRIGERATED AIR DRYER  
A factory mounted, Hankinson HPR 5-10  
series refrigerated air dryer with  
automatic condensate drain trap  
assembly, bypass valve is on all 1/2  
through 3 Hp Powerex duplex air  
compressors. Piping for air dryer is done  
at the factory. Wiring to power source  
must be done in the field using integral  
cord and plug which fits into a standard  
120 volt receptacle. Refer to Table 2 for  
ordering details.  
Single-phase motors have built-in  
overload protection with automatic  
reset. Three-phase motors require a  
manual or magnetic starter and three  
overload heaters. Heaters are included  
with three-phase compressors that have  
a factory mounted alternator.  
alignment while adjusting tension.  
Mounted and  
Connected Options  
AUTOMATIC TANK DRAIN  
DELUXE ALTERNATOR PACKAGE  
All Powerex Duplex air compressors may  
be ordered with an optional deluxe  
alternator package consisting of two  
magnetic motor starts with thermal  
overloads, an alternating coil, a 120  
VAC control transformer and a three-  
position selector switch. The three-  
position switch allows for automatic  
alternation or only running one unit at  
a time. This will allow for service on one  
unit while other unit is running. Refer  
to Table 2 for ordering details and  
figure 4 for wiring diagram.  
LUBRICATION  
Powerex air compressors may be ordered  
with a manual or electric type automatic  
tank drain. A manual drain attachment  
is furnished with each unit. Refer to  
Table 2 for ordering details. (Order  
electric drains separately.)  
Check lubricating oil level at gauge.  
Refill if necessary.  
Change oil according to maintenance  
schedule. Before draining oil, remove  
oil supply cap and loosen oil drain cap  
to release trapped air. Use Mobil Rarus  
427® or Mobil DTE heavy.  
VIBRATION DAMPENING PADS  
Waffle type design vibration pads are  
provided as standard equipment.  
Dispose of oil in  
!
WARNING  
accordance with  
state or local codes.  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
Climate Control Duplex  
LUBRICATION (Continued)  
1. Plug E-drain into 115V power outlet  
supply.  
AUTO E-DRAIN ASSEMBLY (See  
Figure 3)  
2. Adjust timer accordingly.  
NOTE: The automatic E-drain is  
assembled to tank.  
Manifold  
Assembly  
Remove cap and  
add oil  
Oil  
gauge  
Oil drain cap  
Round (red)  
ON  
4
TEST  
OFF  
30  
6
20  
2
8
10  
5
40  
0.5  
10  
0.5  
45  
sec.  
min.  
Full  
Low  
Oil Gauge  
Figure 3 - E-Drain  
Figure 2  
TABLE 2: MODEL NUMBER  
AD  
OR  
Tank Drain/Dryer Options  
Manual Drain,  
Motor Horsepower, Voltage Phase  
Tank Size  
1Ø  
Horsepower  
3Ø  
(Gallons)  
Available on:  
No Dryer = 1  
E-Drain,  
No Dryer = 2  
105 =  
107 =  
110 =  
NA =  
NA =  
NA =  
NA =  
NA =  
NA =  
1/2  
3/4  
1
= 005  
= 007  
= 010  
= 015  
= 020  
= 030  
= 050  
= 075  
= 100  
30 = 1  
1/2 Through 1-1/2 Hp  
1/2 Through 3 Hp  
3 Through 7-1/2 Hp  
5 Through 10 Hp  
80 = 3  
120 = 4  
200 = 5  
Manual Drain,  
}
with Dryer = 3  
E-Drain,  
with Dryer = 4  
112  
2
3
Available on  
1/2 through 3 Hp  
models only.  
5
712  
Starter Options  
10  
Basic  
0=  
Deluxe  
= 0  
None  
2=  
3Ø, 208V  
3Ø, 230V  
3Ø, 460V  
1Ø, 115V  
1 Ø, 208V  
1 Ø, 230V  
= A  
3=  
= B  
Example 1: To order a Duplex air compressor with a  
3/4 Hp single-phase motor, 80 gallon tank, deluxe  
230 volt alternator package, automatic tank drain  
and an air dryer, use product code AD-107-3G4.  
4=  
= C  
5=  
= E  
6=  
= N/A  
= G  
7=  
Example 2: To order a Duplex air compressor with a  
10 Hp three-phase motor, 200 gallon tank and an  
auto drain, use product code AD-100-502.  
1Ø vs 3 Ø selection must agree with  
base model selection  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Climate Control Duplex  
Figure 4  
Deluxe Alternator  
Package Wiring  
Diagram for  
L
L
3
L
2
1
Three-Phase Units  
L
L
L
1
2
3
A2  
A1  
A1  
A2  
Lag Switch  
Cut In: 60 psig (420 kPa)  
Cut-Out: 80 psig (560 kPa)  
Alt  
Lead Switch  
Cut In: 70 psig (490 kPA)  
Cut Out: 90 psig (630 kPa)  
FU  
X1  
FU  
2T 2T 2T  
3
1
2
IT  
IT  
3
IT  
2
1
Motor  
2
Motor  
1
X2  
FU  
2M  
1M  
Selector  
Switch  
Figure 5  
Basic Alternator  
Package Wiring  
Diagram For  
Lag Switch  
Cut In: 60 psig (420 kPa)  
Cut-Out: 80 psig (560 kPa)  
Three-Phase Units  
L
L
L
3
2
1
Red  
PSI  
Single  
Disconnect  
Field Supplied  
Red  
L
1
Black  
Blue  
L
2
L
3
Starter  
Alt R  
Alt L  
Overloads  
Alt C  
IT  
IT  
IT  
1
2
2T  
2T  
3
3
2T  
2
1
Alt  
A251  
1M  
2M  
Motor  
1
Motor  
2
C2  
A151  
A252  
Lead Switch  
Cut In: 70 psig (490 kPA)  
Cut Out: 90 psig (630 kPa)  
PS 2  
PS 2  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Climate Control Duplex  
Plug  
Optional  
Dryer  
A
D
B
C
Discharge  
F
G
E
1/2 Through 10 HP Models  
Figure 6 - Dimensions (in./cm)  
TABLE 3: DIMENSIONS (INCHES) AND SHIPPING WEIGHTS (POUNDS*)  
B
with  
B
Shipping Weight**  
with without  
Alternator Alternator  
Base  
Model  
A
without  
C
D
E
F
G
Alternator Alternator  
AD-105-1XX  
AD-005-1XX  
AD-105-3XX  
AD-005-3XX  
AD-107-1XX  
AD-007-1XX  
AD-107-3XX  
AD-007-3XX  
AD-110-1XX  
AD-010-1XX  
AD-110-3XX  
AD-010-3XX  
AD-015-1XX  
AD-015-3XX  
AD-020-3XX  
AD-030-3XX  
AD-030-4XX  
AD-050-4XX  
AD-050-5XX  
AD-075-4XX  
AD-075-5XX  
AD-100-5XX  
41 12  
64 14  
41 12  
64 14  
41 12  
64 14  
21 14  
22 14  
21 14  
22 14  
21 14  
22 14  
17 34  
20  
35 14  
39  
18  
40  
18  
40  
18  
40  
15 34  
18 12  
15 34  
18 12  
15 34  
18 12  
12 14  
13  
68 12  
77 34  
68 12  
77 34  
68 12  
77 34  
260  
420  
260  
425  
270  
435  
240  
400  
240  
405  
250  
415  
17 34  
20  
36  
12 14  
13  
39  
17 34  
36  
12 14  
20  
39  
13  
41 12  
64 14  
65 14  
65 14  
70 34  
71 14  
81 12  
71 14  
81 12  
84  
21 14  
22 14  
23 14  
23 14  
25 34  
26 14  
30  
26 14  
30  
30  
17 34  
20  
20  
20  
24  
24  
30  
24  
30  
30  
36  
39  
41  
41  
18  
40  
40  
40  
42  
42  
42  
42  
42  
42  
15 34  
18 12  
18 12  
18 12  
22  
22  
22  
22  
22  
12 14  
13  
13  
68 12  
77 34  
90 34  
90 34  
96 14  
270  
435  
500  
650  
780  
930  
1155  
950  
1175  
1440  
250  
415  
480  
630  
760  
910  
1135  
925  
1150  
1415  
13  
44  
15 34  
15 34  
18 34  
15 34  
18 34  
18 34  
49 14  
55 12  
49 14  
55 12  
58  
22  
*Inches x 2.54 = Centimeters, Pounds x 0.454 = Kilograms  
**Add 60.0 lbs. for units equipped with a factory mounted air dryer  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Climate Control Duplex  
E (Behind beltguards)  
L
J
M
D
F
(Behind  
Motor)  
B
C
H
G
A
N
G
K
REPLACEMENT PARTS LIST  
Shipping  
Weight  
(lbs.*)  
Quantity  
Required  
Code  
Number  
Item  
A
Description  
PUMP AND FLYWHEEL:  
Motor Hp 1/2, 3/4  
2
2
2
2
2
2
2
19.5  
35  
59  
A-005-6001  
1, 11⁄  
2
A-010-6001NP  
A-020-6001NP  
A-030-6001NP  
A-050-6001NP  
A-075-6001NP  
A-100-6001NP  
2
3
5
66  
115  
121  
180  
71⁄  
2
10  
B
C
D
E
VALVE KIT: Includes valve plate, spacer and head gasket  
Motor Hp 1/2  
2
2
2
4
4
4
4
6
0.4  
0.4  
0.5  
0.5  
0.7  
1.2  
1.2  
1.2  
A-005-6002  
A-005-6002  
3/4  
1, 11⁄  
2
A-010-6002NP  
A-010-6002NP  
A-030-6002NP  
A-050-6002NP  
A-075-6002NP  
A-075-6002NP  
2
3
5
71⁄  
2
10  
RING/CYLINDER KIT: Includes all compression rings, oil control rings, cylinder, gaskets and sealant  
Motor Hp 1/2  
2
2
2
4
4
4
4
6
3.6  
3.6  
4.8  
4.8  
5.5  
10  
10  
10  
A-005-6004  
A-005-6004  
3/4  
1, 11⁄  
2
A-010-6004NP  
A-010-6004NP  
A-030-6004NP  
A-050-6004NP  
A-075-6004NP  
A-075-6004NP  
2
3 (Kit includes piston)  
5
71⁄  
2
10  
INTAKE FILTER ELEMENT:  
Motor Hp  
1/2  
3/4  
2
2
2
4
4
4
4
6
0.1  
A-005-6023  
A-005-6023  
0.1  
0.2  
0.2  
0.2  
0.2  
0.2  
0.2  
1, 11⁄  
2
A-010-6023NP  
A-030-6023NP  
A-030-6023NP  
A-030-6023NP  
A-030-6023NP  
A-030-6023NP  
2
3
5
71⁄  
2
10  
BELT:  
Motor Hp  
Size  
1/2  
3/4  
1
AX-42  
AX-42  
A-43  
A-46  
A-65  
A-62  
A-65  
A-67  
2
2
2
2
2
2
4
4
0.3  
0.3  
0.3  
0.3  
0.4  
0.4  
1.6  
2.0  
A-005-6006  
A-005-6006  
A-010-6006  
A-015-6006NP  
A-020-6006NP  
A-030-6006NP  
A-050-6006NP  
A-075-6046NP  
11⁄  
2
2
3
5
71⁄  
2
(120 gal tank)  
*lb. x 0.454 = kg  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Climate Control Duplex  
REPLACEMENT PARTS LIST  
Shipping  
Weight  
(lbs.*)  
Quantity  
Required  
Code  
Number  
Item  
E
Description  
BELTS:  
(Continued)  
71⁄  
10  
2
(200 gal tank)  
A-75  
A-84  
4
4
2.0  
2.4  
A-075-6056NP  
A-100-6006NP  
F
MOTOR  
PULLEY:  
Motor Hp  
1/2  
3/4  
Type  
1A-4.4” P.D., 5/8” Bore  
1A-5.8” P.D., 5/8” Bore  
1A-4.0” P.D., 5/8” Bore  
1A-4.0” P.D., 7/8” Bore  
1A-6.0” P.D., 7/8” Bore  
1A-6.0” P.D., 7/8” Bore  
1A-6.0” P.D., 118” Bore  
2A-5.6” P.D., 118” Bore  
2A-7.6” P.D., 138” Bore  
2A-7.6” P.D., 158” Bore  
2
2
2
2
2
2
2
2
2
2
3.8  
3.9  
3.2  
3.2  
5.6  
5.2  
6.3  
7.6  
12.5  
13.5  
A-005-6007  
A-007-6037  
A-110-6007  
A-010-6007  
A-020-6007  
A-020-6007  
A-030-6007NP  
A-050-6007NP  
A-075-6007NP  
A-100-6007NP  
1 (1 Ø)  
1 (3 Ø)  
11⁄  
2
2
3
5
71⁄  
2
10  
G
IN-TANK CHECK VALVE:  
Motor Hp  
Size  
1/2 Through 3  
5 Through 10  
1/2” MPT x 1/2” FPT  
3/4” MPT x 3/4” FPT  
2
2
0.3  
0.4  
A-010-6008  
A-075-6008  
H
J
SAFETY RELIEF VALVE: Set at approximately 115 psig (805 kPa)  
1/2 Through 5 Hp Models  
1
1
0.1  
0.2  
A-050-6009  
A-200-6009  
71⁄  
Through 10 Hp Models  
2
PRESSURE ELECTRIC SWITCHES: (For all models)  
Lead Switch: Set at approximately  
70 psig (490 kPa) cut-in and  
90 psig (630 kPa) cut-out  
1
1
0.9  
0.9  
A-100-6010  
A-100-6011  
Lag Switch: Set at approximately  
60 psig (420 kPa) cut-in and  
80 psig (560kPa) cut-out  
K
L
TANK:  
Motor Hp  
Tank Size  
30 gallon  
80 gallon  
80 gallon  
120 gallon  
120 gallon  
200 gallon  
1/2 Through 11⁄  
2
1
1
1
1
1
1
134.0  
235.0  
243.0  
398.0  
415.0  
677.0  
A-010-6030NP  
A-010-6060NP  
A-020-6060NP  
A-020-6080NP  
A-050-6120NP  
A-100-6200NP  
1/2 Through 11⁄  
2 & 3  
2
2 & 3  
5 & 71⁄  
2
5 Through 10  
COOLING  
SHROUD:  
Motor Hp  
1/2  
3/4  
2
2
2
2
2
2
2
2
1.0  
1.0  
1.7  
1.7  
1.7  
1.9  
4.5  
A-005-6013  
A-005-6013  
A-020-6013NP  
A-030-6013NP  
A-050-6013NP  
A-075-6013NP  
A-100-6013NP  
3
5
71⁄  
2
10  
BELT GUARD: Motor Hp  
1/2 Through 11⁄  
M
N
2
2
2
2
2
2.4  
12.5  
12.5  
18.5  
A-010-6012  
A-020-6012  
A-050-6012  
A-100-6012  
2 & 3  
5 & 71⁄  
10  
2
LIQUID GASKET:1 through 10 Hp  
1
0.4  
A-999-6000  
*lb. x 0.454 = kg  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Climate Control Duplex  
Maintenance Schedule  
Operating Hours  
Item  
Action needed  
500  
2500  
5000  
10,000  
15,000  
20,000  
Remarks  
Tank  
Inlet air filter  
Blower fan  
Drain moisture  
Replace  
Clean  
Daily  
G
L
(Every 2,500 hrs or less)  
G
G
G
G
G
G
Fan duct  
Clean  
G
G
Compressor fins  
Oil change  
Clean  
Replace  
G
(Every 2,500 hrs or less)  
(Every 1,500 hrs)  
Compression rings  
Check oil  
V-belt  
Replace  
Inspect  
Inspect, replace  
Confirm operation  
L
L
Daily  
*Note 3  
G
L
L
G
L
G
Pressure switch  
Magnetic starter  
Inspect  
G
G
Replace if contact  
points deteriorated  
Safety valve  
Pressure gauge  
Confirm operation  
Inspect  
G
G
(Every 2,500 hrs or less)  
(Every 2,500 hrs or less)  
G
Inspect  
L
Replace  
NOTES:  
1. Inspect and perform maintenance periodically according to maintenance schedule.  
2. The maintenance schedule relates to the normal operating conditions. If the circumstances and load condition are adverse, shorten the  
cycle time and do maintenance accordingly.  
3. *The tension of the V-belt should be adjusted during initial start up and inspected every 1,500 hours afterwards. Proper belt tension for  
3/4 to 3 Hp units is 2-3 lbs./5deflection; for 5 to 10 Hp units, 4-6 lbs./.5deflection.  
Powerex Limited Warranty  
Powerex 3 Year / 10,000 Hour Extended Parts Limited Warranty - Powerex warrants each Compressor Pump or Scroll Air-End  
against defects in material or workmanship from the date of purchase for a period of Three years or 10,000 hours, whichever may  
occur first. This warranty applies to the exchange of part(s) of the compressor pump or air-end found to be defective by an Authorized  
Powerex Service Center.  
Powerex 1 Year / 5,000 Hour Inlet to Outlet Limited Warranty - Powerex warrants each Compressor Unit, System, Pump, or Air-  
End against defects in material or workmanship from the date of purchase for a period of One Year or 5,000 Hours, whichever may  
occur first. This warranty applies to the exchange of defective component part(s) and labor performed by an Authorized Powerex  
Service Center.  
The above mentioned warranty applies to POWEREX manufactured units or systems only.  
Items listed in the operator’s manual under routine maintenance are not covered by  
this or any other warranty.  
THERE IS NO OTHER EXPRESS WARRANTY. IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A  
PARTICULAR PURPOSE, ARE LIMITED TO ONE YEAR FROM THE DATE OF PURCHASE: AND TO THE EXTENT PERMITTED BY LAW, ANY  
AND ALL IMPLIED WARRANTIES ARE EXCLUDED. THIS IS THE EXCLUSIVE REMEDY AND LIABILITY FOR CONSEQUENTIAL DAMAGES  
UNDER ANY AND ALL WARRANTIES IS EXCLUDED TO THE EXTENT EXCLUSION IS PERMITTED BY LAW.  
All claims pertaining to the merchandise in this schedule, with the exception of warranty claims, must be filed with POWEREX within 6  
months of the invoice date, or they will not be honored. Prices, discounts and terms are subject to change without notice or as  
stipulated in specific product quotations. All agreements are contingent upon strikes, accidents, or other causes beyond our control. All  
shipments are carefully inspected and counted before leaving the factory. Please inspect carefully any receipt of merchandise noting  
any discrepancy or damage on the carrier’s freight bill at the time of delivery. Discrepancies or damage which obviously occurred in  
transit are the carrier’s responsibility and related claims should be made promptly directly to the carrier. Returned merchandise will not  
be accepted without prior written authorization by POWEREX and deductions from invoices for shortage or damage claims will not be  
allowed. UNLESS OTHERWISE AGREED TO IN WRITING, THESE TERMS AND CONDITIONS WILL CONTROL IN ANY TRANSACTION  
WITH POWEREX any different or conflicting terms as may appear on any order form now or later submitted by the buyer. All orders  
are subject to acceptance by POWEREX.  
150 Production Drive  
Harrison, OH 45030  
Phone: 1-888-769-7979  
Fax: 513-367-3125  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
P
U
R
E
A
I
R
T
E
C
H
N
O
L
O
G
Y
General Product Manual  
Lubricated Compressor Pumps  
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.  
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or prop-  
erty damage! Retain instructions for future reference.  
effect of excessive ring and cylinder  
wear. Piston rings should be replaced  
every 15,000 hours of operation.  
Descriptions  
!
DANGER  
GENERAL  
Breathable Air Warning  
The Powerex reciprocating air compres-  
sor has advanced compressor technolo-  
gy. The Powerex reciprocating com-  
pressor is available in single stage  
model. Individually precision machined  
cylinders and lap joint rings provide the  
lowest oil carryover in the industry. The  
onboard cooling fan and finned fly-  
wheel create lower operating tempera-  
tures.  
VALVING  
This compressor/pump is NOT  
equipped and should NOT be used  
“as is” to supply breathing quality  
air. For any application of air for  
human consumption, you must fit  
the compressor/pump with suitable  
in-line safety and alarm equipment.  
This additional equipment is neces-  
sary to properly filter and purify  
the air to meet minimal specifica-  
tions for Grade D breathing as  
described in Compressed Gas  
Low lift Swedish stainless steel valves  
resist carbon build-up and offer out-  
standing durability. The reduced num-  
ber of valves lessens the risk of failure.  
Installation  
INSTALLATION SITE  
1. The compressor must be located in a  
clean, well lit and well ventilated  
area.  
DRY TYPE INLET FILTER  
2. The area should be free of excessive  
dust, toxic or flammable gases and  
moisture.  
The inlet filter on the Powerex com-  
pressor assures 99% of particulate free  
air is admitted to the unit. Change  
every 500 hours or more often in dirty  
locations.  
Association Commodity  
Specification G 7.1 - 1966, OSHA 29  
CFR 1910. 134, and/or Canadian  
Standards Associations (CSA).  
3. Never install the compressor where  
the ambient temperature is higher  
than 104 F or where humidity is high.  
o
DISCLAIMER OF WARRANTIES  
PISTON RINGS AND CYLINDERS  
In the event the compressor/pump  
is used for the purpose of breathing  
air application and proper in-line  
safety and alarm equipment is not  
simultaneously used, existing war-  
ranties are void, and Powerex dis-  
claims any liability whatsoever for  
any loss, personal injury or damage.  
4. Clearance must allow for safe, effec-  
tive inspection and maintenance.  
The Powerex reciprocating compressor  
cylinder is made of a 390R cast alloy  
construction machined with the most  
advanced technology available. These  
heat reducing cylinders eliminate the  
5. If necessary, use metal shims or level-  
ing pads to level the compressor.  
Never use wood to shim the com-  
pressor.  
Figure 1 - Models CS100P, LPS010, LPS020, LPS030, LPS075, LPS100  
Powerex • 150 Production Drive • Harrison, OH 45030 • USA  
IN259102AV 3/01  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Reciprocating Air Compressor Pumps  
VENTILATION  
SAFETY VALVES  
7. Make sure the inlet filter is properly  
installed.  
1. If the compressor is located in a total-  
ly enclosed room, an exhaust fan  
with access to outside air must be  
installed.  
Tank mounted compressors are shipped  
from the factory with safety valves  
installed in the tank manifold. The flow  
capacity of the safety valve is equal to  
or greater than the capacity of the  
compressor.  
8. Confirm that the drain valve is closed.  
9. Visually check the rotation of the  
compressor pump. If the rotation is  
incorrect, have a qualified electrician  
correct the motor wiring.  
2. Never restrict the cooling fan exhaust  
air.  
1. The pressure setting of the safety  
valve must be no higher than the  
maximum working pressure of the  
tank.  
3. Never locate the compressor where hot  
exhaust air from other heat generating  
units may be pulled into the unit.  
START-UP AND OPERATION  
1. Follow all the procedures under  
“Before start-up” before attempting  
operation of the compressor.  
Minimum Clearances  
2. Safety valves should be placed ahead  
of any possible blockage point in the  
system, i.e. shutoff valve.  
2. Switch the electric source breaker on.  
Above  
24”  
12”  
20”  
3. Open the tank discharge valve com-  
pletely.  
Drive belt side  
Other sides  
3. Avoid connecting the safety valve  
with any tubing or piping.  
4. Check that the compressor operates  
without excessive vibration, unusual  
noises or leaks.  
WIRING  
4. Manually operate the safety valve  
every six months to avoid sticking or  
freezing.  
Refer to the general product manual.  
All electrical hook-ups must be per-  
formed by a qualified electrician.  
Installations must be in accordance  
with local and national electrical codes.  
5. Close the discharge valve completely.  
6. Check the discharge pressure. Also  
make sure the air pressure rises to the  
designated pressure setting by check-  
ing the discharge pressure gauge.  
Operation  
Powerex single stage compressors oper-  
ate at a maximum pressure of 140 PSIG.  
Compressor RPM’s are established by  
Powerex based on horsepower and  
operating pressure.  
Use solderless terminals to connect the  
electric power source.  
7. Check the operation of the pressure  
switch or the pilot valve for continu-  
ous run units by opening the stop  
valve and confirming the compressor  
starts or reloads as pressure drops.  
PIPING  
Refer to the general product manual.  
1. Make sure the piping is lined up  
without being strained or twisted  
when assembling the piping for the  
scroll compressor.  
BEFORE START UP  
1. Make sure all safety warnings, labels  
and instructions have been read and  
understood before continuing.  
Switch the breaker OFF if the compres-  
sor is not to be used for a long period  
of time.  
2. Appropriate expansion loops or  
bends should be installed at the com-  
pressor to avoid stresses caused by  
changes in hot and cold conditions.  
2. Remove any shipping materials,  
brackets, etc.  
Two stage units are  
equipped with head  
unloaders for continuous operation.  
NOTICE  
3. Confirm that the electric power  
source and ground have been firmly  
connected.  
3. Piping supports should be anchored  
separately from the compressor to  
reduce noise and vibration.  
4. Be sure all pressure connections are  
tight.  
4. Never use any piping smaller than  
the compressor connection.  
5. Check to be certain all safety relief  
valves, etc., are correctly installed.  
5. Use flexible hose to connect the out-  
let of the compressor to the piping so  
that the vibration of the compressor  
does not transfer to the piping.  
6. Check that all fuses, circuit breakers,  
etc., are the proper size.  
Dimensions (Refer to Figure 2)  
Max  
psig  
SCFM @  
100 psig  
RPM @  
100 PSIG  
Number/  
Cylinders Bore  
Flywheel  
Stroke Outer Diam.  
Weight  
(lbs.)  
Model  
HP  
Drive  
CS100P .75/.5  
140  
140  
140  
140  
140  
140  
2.3/1.7  
5.1/3.4  
7.7  
990/805  
900/665  
720  
1
1
2
2
2
3
1.9  
2.6  
2.6  
3.0  
4.1  
4.1  
2.2  
11.2  
10.5  
13.7  
14.6  
18.3  
19.7  
1GR-A  
1GR-A  
1GR-B  
1GR-B  
2GR-B  
2GR-B  
28  
LPS010  
LPS020  
LPS030  
LPS075  
LPS100  
1.5/1  
2
2.6  
34  
2.4  
65  
5/3  
15.4/11.5  
29.2  
1050/765  
790  
2.9  
76  
7.5  
3.35  
3.35  
116  
137  
15/10  
62.1/41.3  
1080/695  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
Reciprocating Air Compressor Pumps  
7.5”  
11.9”  
10.8  
9.4  
16.2”  
13.9  
3.7  
7.9  
3.2”  
6.7”  
LPS 010  
CS100P  
18.9”  
11.9”  
22.8”  
15.0”  
17.8”  
20.2”  
8.3”  
4.4”  
4.4”  
11.5”  
26.0”  
LPS 020  
LPS 030  
18.0”  
26.0”  
18.0”  
21.8”  
21.8”  
5.3”  
5.3”  
11.4”  
11.4”  
LPS 075  
LPS050  
29.7”  
20.1”  
21.7”  
6.3”  
LPS 100  
Figure 2 - Dimensional Drawings  
12.2”  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Reciprocating Air Compressor Pumps  
Maintenance Schedule  
Operating Hours  
5,000 10,000  
Item  
Action needed  
500  
2,500  
15,000  
20,000  
Remarks  
Tank  
Inlet air filter  
Blower fan  
Drain moisture  
Replace  
Clean  
Daily  
G
G
(Every 2,500 hrs or less)  
G
G
G
G
G
Fan shroud  
Clean  
G
G
G
Compressor fins  
Oil change  
Clean  
Replace  
G
(Every 2,500 hrs or less)  
(Every 1,500 hrs)  
Compression rings Replace  
G
Check oil  
Inspect  
Daily  
V-belt  
Pressure switch  
Inspect, replace  
Confirm operation  
*Note 3  
G
G
G
G
G
G
G
Magnetic starter Inspect  
G
G
Replace if contact  
points deteriorated  
Safety valve  
Pressure gauge  
Confirm operation  
Inspect  
G
G
(Every 2,500 hrs or less)  
(Every 2,500 hrs or less)  
G
G
Inspect  
Replace  
NOTES:  
1. Inspect and perform maintenance periodically according to maintenance schedule.  
2. The maintenance schedule relates to the normal operating conditions. If the circumstances and load condition are adverse,  
shorten the cycle time and do maintenance accordingly.  
3. * The tension of the V-belt should be adjusted during initial start up and inspected every 1,500 hours afterwards. Proper  
belt tension for 3/4 to 3 HP units is 2-3 lbs./.5” deflection; for 5 to 10 HP units, 4-6 lbs./.5” deflection.  
Oil Level  
To check lubricating oil, see oil gauge. Refill if necessary.  
Remove cap  
and add oil  
using funnel  
How to Read Oil Gauge  
Full  
Low  
Round (red)  
Oil gauge  
Oil Change  
Replace lubricating oil fully within designated time. Before  
draining oil, remove oil supply cap and then oil drain cap in  
order to release air.  
RECOMMENDED OIL  
Mobil Rarus 427, Shell Turbo T68, Exxon Esstic T68 and Texaco  
Rando T68.  
CLIMATE CONTROL APPLICATIONS  
Mobil DTE Heavy and Mobil Rarus 427  
Dispose of oil in accordance with  
state or local codes.  
!
WARNING  
Oil drain cap  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Reciprocating Air Compressor Pumps  
Air Filter Replacement  
Ring Replacement Every 15,000 Hours  
1. Remove wing nut.  
1. Remove cylinder head  
bolts on each cylinder.  
2. Remove canister and wipe  
after removing old cartridge.  
2. Remove and discard form seal  
or gasket.  
3. Remove and discard filter  
cartridge.  
4. Install new filter cartridge.  
Do not attempt to clean  
and reuse filter cartridge.  
3. Replace form seal or gasket.  
4. Remove valve plate and clean  
with dry cloth.  
Wipe clean with dry cloth  
once new filter is in place.  
5. Remove and discard cylinder  
seal or gasket.  
6. Replace with the new seal or  
gasket.  
Figure 3 - Air Filter Replacement  
7. Remove and discard valve  
wear pad.  
8. Replace with new pad.  
Cylinder Bolt Torque  
9. Remove cylinder bolts and  
cylinder. Note the cylinder  
orientation. Inspect for  
abnormal wear.  
Torque  
(in. lb.)  
Model  
CS100P  
LPS010  
LPS020  
LPS030  
LPS050  
LPS075  
LPS100  
156  
156  
156  
156  
295  
295  
295  
NOTE: Liquid gasket required  
between cylinder & crankcase  
and bearing cap on all LPS  
Models (P. N. #JP013400AV).  
10. Remove piston rings.  
11. Replace rings. Orientate ends  
180˚ opposite from each other.  
12. Apply thin continuous layer of  
liquid gasket to cylinder flange.  
Install cylinder. Be careful of  
orientation. Torque cylinder  
bolts (See chart).  
13. Install valve set with new seals.  
14. Install head and cylinder head  
bolts. Torque head bolts (See  
chart).  
Head Bolt Torque  
Torque  
(in. lb.)  
Model  
CS100P  
LPS010  
LPS020  
LPS030  
LPS050  
LPS075  
LPS100  
156  
156  
156  
156  
295  
156  
156  
Figure 4 - Ring Replacement  
15. Unit is ready for full operation.  
No break-in is required.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Reciprocating Air Compressor Pumps  
CS100P  
27  
26  
28  
25  
29  
23  
24  
24  
21  
20  
22  
19  
30  
3
14  
1
12  
10  
2
7
17  
11  
18  
16  
4
8
9
13  
15  
16  
5
6
Figure 5 - Replacement Parts Illustration  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Reciprocating Air Compressor Pumps  
CS100P  
Ref.  
No.  
Description  
Part Number  
Qty  
1
2
Cylinder  
IP036000AV  
IP035901AV  
IP035800AV  
G
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
2
1
1
1
1
1
1
1
2
1
1
1
1
1
1
Cylinder gasket  
Cylinder head  
3
4
Crank case  
5
Bearing case  
G
6
Bearing case gasket  
Oil gauge set  
IP035301AV  
91117120  
7
8
Oil drain pipe  
IP031701AV  
IP001900AV  
IP002100AV  
IP035200AV  
IP035100AV  
IP035000AV  
IP002700AV  
IP003000AV  
IP031300AV  
IP034900AV  
IP034800AV  
IP033800AV  
IP033700AV  
IP033600AV  
IP033500AV  
IP033300AV  
IP033200AV  
IP305000AV  
IP032800AV  
IP032701AV  
IP032601AV  
IP032500AV  
IP630100AV  
9
Oil drain cap with gasket  
Breather assembly with gasket  
Fan side rubber seal  
Crank shaft  
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
G
Flywheel  
Woodruff key  
Oil seal  
Ball bearing  
Fan  
Fan shroud  
Connecting rod  
Piston Assembly (Includes items 22 - 24)  
Piston ring set  
Piston  
Piston pin  
Stop ring  
Valve assembly (Includes items 27 - 28)  
Valve plate  
Cylinder head gasket  
Valve spacer gasket  
Air intake filter cover  
Air intake filter element  
Replace Pump  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Reciprocating Air Compressor Pumps  
LPS010  
3
2
20  
24  
27  
23  
26  
1
21  
C
22  
17  
16  
25  
13  
14  
C
19  
18  
19  
12  
28  
9
5
15  
28  
11  
29  
15  
6
10  
NOTE: Apply a thin layer of liquid gasket  
to entire surface of Item 28.  
8
4
7
Figure 6 - Replacement Parts Illustration  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Reciprocating Air Compressor Pumps  
LPS010  
Ref.  
No.  
Description  
Part Number  
Qty  
1
2
Cylinder  
91000560  
91003550  
01052041  
G
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
1
2
1
1
1
1
1
1
1
1
1
1
Cylinder head  
Unloader cap  
Crank case  
3
4
5
Bearing cap  
G
6
Oil gauge  
01909600  
01119400  
01120023  
01919470  
01146550  
91223551  
91201551  
06600008  
07192201  
07112200  
91902560  
91924120  
01232120  
06613160  
91906550  
91348550  
01301560  
01909400  
01161470  
91251550  
91935560  
91933560  
JP013400AV  
01120600  
7
Oil drain pipe  
Oil drain cap set  
Breather assembly and gasket  
Bearing cap rubber seal  
Crankshaft  
8
9
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
Pulley flywheel  
Key woodruff  
Bearing cap oil seal  
Bearing cap ball bearing  
Piston  
Piston ring set  
Wrist pin  
Retainer  
Intake filter set  
Intake filter  
Intake valve seat  
Tube  
Return tube nipple  
Connecting rod  
Valve gasket set  
Valve set with gasket  
Liquid gasket  
Oil gauge gasket  
Not shown  
G
Replace Pump  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Reciprocating Air Compressor Pumps  
LPS020  
29  
30  
34  
5
31  
B
37  
31  
32  
C
38  
34  
35  
6
13  
7
3
17  
25  
21  
23  
B
20  
42  
16  
8
9
18  
18  
22  
14  
19  
15  
42  
43  
4
11  
2
12  
C
10  
40  
41  
33  
36  
1
26  
39  
24  
28  
27  
25  
NOTE: Apply a thin layer of liquid gasket  
to entire surface of Item 42.  
Figure 7 - Replacement Parts Illustration  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Reciprocating Air Compressor Pumps  
LPS020  
Ref.  
No.  
Description  
Part Number  
Qty  
1
2
Cylinder  
91000560  
91003560  
06800261  
01052041  
91345561  
91346571  
91176580  
G
2
2
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
2
2
2
4
1
1
2
1
2
2
1
2
1
1
2
2
2
1
1
Cylinder head  
3
Intake return pipe elbow  
Unloader cap  
4
5
Intake joint (1)  
6
Intake joint (2)  
7
Breather flange  
Crankcase  
8
9
Bearing cap  
G
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
32  
33  
34  
35  
36  
37  
38  
39  
40  
41  
42  
43  
Oil gauge  
01909600  
01119400  
91908600  
01919470  
01146560  
91214560  
91202560  
0660013  
Oil drain pipe  
Oil drain cap assembly  
Breather assembly and gasket  
Bearing cap rubber seal  
Crank shaft  
Flywheel pulley  
Key woodruff  
Bearing cap oil seal  
Bearing cap ball bearing  
Crank case ball bearing  
Fan  
07192252  
07112250  
07112300  
91220560  
91134560  
91251560  
91224560  
91902560  
91924120  
01232120  
06613160  
91907570  
91353660  
06630032  
91407560  
01301560  
06639906  
01909400  
91135560  
01095570  
01095560  
91935560  
91933560  
01471452  
JP013400AV  
01120600  
Fan cover  
Right connecting rod (Facing flywheel)  
Left connecting rod (Facing flywheel)  
Piston set with rings  
Piston ring set  
Wrist pin  
Retainer  
Intake filter set  
Intake filter  
Intake pipe o-ring  
Intake pipe  
Intake valve seat  
Intake joint o-ring  
Tube  
Fan guard  
Intake joint bolt  
Intake joint bolt  
Valve gasket set  
Valve set with gasket  
Rubber seal (Unloader piston)  
Liquid gasket  
Oil gauge gasket  
Not shown.  
G
Replace Pump  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Reciprocating Air Compressor Pumps  
LPS030  
29  
30  
34  
5
39  
31  
35  
38  
B
31  
32  
6
C
9
34  
13  
3
14  
25  
17  
7
23  
20  
8
43  
18  
16  
19  
21  
15  
18  
22  
36  
43  
D
4
11  
12  
2
44  
10  
C
33  
42  
37  
41  
1
40  
26  
24  
28  
27  
D
NOTE: Apply a thin layer of liquid gasket  
to entire surface of Item 43.  
28  
25  
Figure 8 - Replacement Parts Illustration  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Reciprocating Air Compressor Pumps  
LPS030  
Ref.  
No.  
Description  
Part Number  
Qty  
1
2
Cylinder  
91033570  
91004600  
06800281  
01052451  
91345570  
91346571  
91176580  
G
2
2
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
2
2
2
4
1
1
2
1
2
2
1
1
2
1
1
2
2
2
1
1
Cylinder head  
3
Intake return pipe elbow  
Unloader cap  
4
5
Intake joint (1)  
6
Intake joint (2)  
7
Breather flange  
Crankcase  
8
9
Bearing cap  
G
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
32  
33  
34  
35  
36  
37  
38  
39  
40  
41  
42  
43  
44  
Oil gauge  
01909600  
01119430  
91908600  
01919600  
06634062  
91214570  
91201570  
06600013  
07192302  
07112300  
07113300  
91220570  
91134570  
91224570  
91936570  
91903571  
91946571  
01232041  
01240581  
91907570  
91353660  
06630032  
91407570  
01301692  
06639906  
91162570  
91240570  
91144570  
01095570  
01344690  
91936601  
91934603  
01471452  
JP013400AV  
01120600  
Oil drain pipe  
Oil drain cap set  
Breather assembly and gasket  
Bearing cap rubber seal  
Crankshaft  
Pulley flywheel  
Key woodruff  
Bearing cap oil seal  
Bearing cap ball bearing  
Crankcase ball bearing  
Fan  
Fan cover  
Right connecting rod (Facing flywheel)  
Left connecting rod (Facing flywheel)  
Piston set with rings  
Piston ring set  
Wrist pin  
Retainer  
Intake filter set  
Intake filter  
Intake pipe o-ring  
Intake pipe  
Intake valve seat  
Intake joint o-ring  
Return pipe  
Fan retainer oil seal  
Fan shield  
Intake joint bolt  
Intake joint bolt  
Valve set with gasket  
Valve gasket set  
Rubber seal (Unloader piston)  
Liquid gasket  
Oil gauge gasket  
Not shown.  
G
Replace Pump  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Reciprocating Air Compressor Pumps  
LPS050  
31  
30  
31  
30  
33  
42  
16  
5
3
42  
35  
27  
C
5
33  
17  
28  
29  
13  
24  
26  
21  
6
45  
7
45  
15 20  
22  
18  
14  
19  
23  
40  
8
37  
38  
4
39  
36  
11  
12  
2
D
10  
9
43  
C
34  
41  
32  
1
26  
25  
D
44  
Note: Apply a thin layer of liquid gasket to  
entire surface of item #45.  
Figure 9 - Replacement Parts Illustration  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Reciprocating Air Compressor Pumps  
LPS050  
Ref.  
No.  
Description  
Part Number  
Qty  
1
2
Cylinder  
91000590  
91005580  
06801281  
01052451  
91345660  
91176580  
G
2
2
1
2
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
2
2
4
2
2
2
2
2
1
1
1
1
1
1
2
2
2
2
1
Cylinder head  
Intake return pipe fitting  
Unloader cap  
Intake joint  
3
4
5
6
Breather flange  
Crank case  
7
8
Bearing case  
G
9
Oil gauge  
91909600  
01120600  
91119430  
91908600  
91919600  
01146430  
91200580  
91201580  
06600016  
07192355  
07192405  
07112350  
07113400  
91220690  
91134660  
91207600  
91901600  
91902590  
91924590  
01232060  
01240040  
91907660  
91353660  
01301691  
06639906  
01471452  
01909400  
01117600  
01118600  
01121600  
01123601  
01148600  
91144660  
01344690  
91933591  
91936590  
JP013400AV  
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
32  
33  
34  
35  
36  
37  
38  
39  
40  
41  
42  
43  
44  
45  
Packing-oil gauge  
Oil drain pipe  
Oil drain cap set  
Breather set  
Bearing cap rubber seal  
Crank shaft  
Flywheel pulley  
Woodruff key  
Oil seal  
Oil seal  
Bearing cap ball bearing  
Crack case ball bearing  
Fan  
Fan cover  
Right connecting rod (facing flywheel)  
Left connecting rod (facing flywheel)  
Piston set  
Piston ring set  
Piston pin  
Retainer  
Intake filter set  
Filter set  
Seat  
Intake joint o-ring  
Unloader cap seal  
Return pipe  
Oil gauge adapter  
Oil gauge adapter lid  
Gasket  
Adapter packing  
Retainer  
Fan guard  
Intake joint bolt  
Valve set with gasket  
Valve gasket set  
Liquid gasket  
Not shown.  
G
Replace Pump  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Reciprocating Air Compressor Pumps  
LPS075  
30  
29  
30  
29  
32  
40  
15  
5
3
40  
33  
26  
C
5
32  
16  
27  
28  
12  
23  
25  
20  
6
44  
7
14 19  
21  
17  
13  
18  
22  
38  
8
35  
36  
44  
4
37  
34  
10  
11  
2
D
45  
9
41  
C
43  
39  
31  
1
25  
24  
D
42  
NOTE: Apply a thin layer of liquid gasket  
to entire surface of Item 44.  
Figure 10 - Replacement Parts Illustration  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Reciprocating Air Compressor Pumps  
LPS075  
Ref.  
No.  
Description  
Part Number  
Qty  
1
2
Cylinder  
91000600  
91005600  
06801281  
01052451  
91345660  
91176580  
G
2
2
1
2
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
2
2
4
2
2
2
2
1
1
1
1
1
1
2
2
2
2
3
1
1
Cylinder head  
3
Intake return pipe fitting  
Unloader cap  
4
5
Intake joint  
6
Breather flange  
Crankcase  
7
8
Bearing cap  
G
9
Oil gauge  
01909600  
01119430  
91908600  
01919600  
01146430  
91200580  
91201580  
06600016  
07192355  
07192405  
07112350  
07113400  
91220690  
91134660  
91207600  
91901600  
91902600  
91946600  
01232060  
01240040  
91907660  
91353660  
01301692  
06639906  
91162580  
01117600  
01118600  
01121600  
01123601  
01148600  
91144660  
01344690  
91937600  
91933601  
01471452  
JP013400AV  
01120600  
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
32  
33  
34  
35  
36  
37  
38  
39  
40  
41  
42  
43  
44  
45  
Oil drain pipe  
Oil drain cap set  
Breather assembly and gasket  
Bearing cap rubber seal  
Crank shaft  
Pulley flywheel  
Key woodruff  
Bearing cap oil seal  
Crank case oil seal  
Bearing cap ball bearing  
Crankcase ball bearing  
Fan  
Fan cover  
Right connecting rod (Facing flywheel)  
Left connecting rod (Facing flywheel)  
Piston set  
Piston ring set  
Wrist pin  
Retainer  
Intake filter set  
Intake filter  
Intake valve seat  
Intake joint o-ring  
Return pipe  
Oil gauge case  
Oil gauge cap  
Oil gauge case gasket  
Oil gauge crank case gasket  
Retainer fan oil seal  
Fan guard  
Intake joint bolt  
Valve set with gasket  
Valve gasket set  
Rubber seal (Unloader cap)  
Liquid gasket  
Oil gauge gasket  
Not shown.  
G
Replace Pump  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Reciprocating Air Compressor Pumps  
LPS100  
29  
45  
4
48  
5
29  
32  
30  
2
46  
47  
5
45  
31  
3
NOTE: Apply a thin layer of liquid  
gasket to entire surface of Item 49.  
32  
35  
1
26  
25  
25  
27  
36  
18  
17  
28  
24  
42  
15  
33  
13  
49  
21  
16  
8
14  
34  
19  
43  
20  
38  
49  
6
36  
23  
40  
39  
37  
10  
7
11  
45  
41  
12  
5
22  
48  
32  
9
4
24  
25  
44  
Figure 11 - Replacement Parts Illustration  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Reciprocating Air Compressor Pumps  
LPS100  
Ref.  
No.  
Description  
Part Number  
Qty  
1
2
3
4
5
6
7
8
9
Cylinder  
Cylinder head  
Intake return pipe elbow  
Unloader cap  
Intake joint  
Oil cap joint  
Crank case  
Bearing cap  
Oil gauge  
91000600  
91005600  
06801281  
01052451  
91345660  
01122600  
G
3
3
1
3
3
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
3
3
3
6
3
3
3
3
1
2
1
1
1
1
1
1
1
2
1
2
3
3
3
3
1
G
01909600  
01120600  
01119430  
91908600  
01919600  
01146690  
91200600  
01201600  
06600016  
07192452  
07192405  
07113450  
07112500  
91220690  
91134690  
91901600  
91902600  
91946600  
01232060  
01240040  
91907660  
91353660  
01301692  
06639906  
01918600  
01413690  
91162580  
91207600  
01117600  
01118600  
01121600  
01123601  
01148600  
01138600  
01139600  
01135690  
01344690  
91937600  
91933601  
01471452  
JP013400AV  
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
32  
33  
34  
35  
36  
37  
38  
39  
40  
41  
42  
43  
44  
45  
46  
47  
48  
49  
Gasket  
Oil drain pipe  
Oil drain cap set  
Breather assembly and gasket  
Bearing cap rubber seal  
Crank shaft  
Pulley flywheel  
Key woodruff  
Bearing cap oil seal  
Crank case oil seal  
Bearing cap ball bearing  
Crank case ball bearing  
Fan  
Fan cover  
Left and right connecting rods  
Piston set  
Piston ring set  
Wrist pin  
Retainer  
Intake filter set  
Intake filter  
Intake valve seat  
Intake joint o-ring  
Oil cap  
Cover bracket  
Return pipe  
Center connecting rod  
Oil gauge case  
Oil gauge cap  
Oil gauge case gasket  
Oil gauge crank case gasket  
Oil seal fan retainer  
Bypass joint  
Bypass pipe  
Fan guard  
Intake joint bolt  
Valve gasket set  
Valve set with gasket  
Rubber seal (Unloader piston)  
Liquid gasket  
Not shown.  
G
Replace Pump  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Powerex Limited Warranty  
Powerex 3 Year / 10,000 Hour Extended Parts Limited Warranty - Powerex warrants each Compressor  
Pump or Scroll Air-End against defects in material or workmanship from the date of purchase for a period of  
Three years or 10,000 hours, whichever may occur first. This warranty applies to the exchange of part(s) of the  
compressor pump or air-end found to be defective by an Authorized Powerex Service Center.  
Powerex 1 Year / 5,000 Hour Inlet to Outlet Limited Warranty - Powerex warrants each Compressor Unit,  
System, Pump, or Air-End against defects in material or workmanship from the date of purchase for a period of  
One Year or 5,000 Hours, whichever may occur first. This warranty applies to the exchange of defective com-  
ponent part(s) and labor performed by an Authorized Powerex Service Center.  
The above mentioned warranty applies to POWEREX manufactured units or systems only.  
Items listed in the operator’s manual under routine maintenance are not covered by this or any other warranty.  
THERE IS NO OTHER EXPRESS WARRANTY. IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY  
AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO ONE YEAR FROM THE DATE OF PURCHASE: AND  
TO THE EXTENT PERMITTED BY LAW, ANY AND ALL IMPLIED WARRANTIES ARE EXCLUDED. THIS IS THE EXCLU-  
SIVE REMEDY AND LIABILITY FOR CONSEQUENTIAL DAMAGES UNDER ANY AND ALL WARRANTIES IS EXCLUD-  
ED TO THE EXTENT EXCLUSION IS PERMITTED BY LAW.  
All claims pertaining to the merchandise in this schedule, with the exception of warranty claims, must be filed  
with POWEREX within 6 months of the invoice date, or they will not be honored. Prices, discounts and terms are  
subject to change without notice or as stipulated in specific product quotations. All agreements are contingent  
upon strikes, accidents, or other causes beyond our control. All shipments are carefully inspected and counted  
before leaving the factory. Please inspect carefully any receipt of merchandise noting any discrepancy or dam-  
age on the carrier’s freight bill at the time of delivery. Discrepancies or damage which obviously occurred in  
transit are the carrier’s responsibility and related claims should be made promptly directly to the carrier.  
Returned merchandise will not be accepted without prior written authorization by POWEREX and deductions  
from invoices for shortage or damage claims will not be allowed. UNLESS OTHERWISE AGREED TO IN WRIT-  
ING, THESE TERMS AND CONDITIONS WILL CONTROL IN ANY TRANSACTION WITH POWEREX any differ-  
ent or conflicting terms as may appear on any order form now or later submitted by the buyer. All orders are  
subject to acceptance by POWEREX.  
Limited warranty applies in the U.S. and Canada only and gives you specific legal rights. You may also have  
other rights which vary from state to state or country to country.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Peavey Guitar 80302173 User Manual
Peerless Industries TV Mount PT640 User Manual
Philips Cassette Player AQ6401 User Manual
Philips DVD Player DVD612S 25 User Manual
Philips Skin Care Product HB585 User Manual
Philips Speaker System MCM239D User Manual
Pioneer Satellite Radio GEX P900DAB User Manual
Polaroid Stereo System IC V8000 User Manual
Polycom Server DOC2547A User Manual
Power Acoustik Stereo Equalizer PEQ 72 User Manual