ESPAÑOL: PÁGINA 15
FRANÇAISE : PAGE 29
Instruction
manual
Bayonet Saw
MODEL
548
IMPORTANT
Please make certain that the person who is
to use this equipment carefully reads and
understands these instructions before
starting operations.
To learn more about Porter-Cable
visit our website at:
The Model and Serial No. plate is located on the main
housing of the tool. Record these numbers in the
spaces below and retain for future reference.
Model No. ______________________________________
Type ___________________________________________
Serial No._______________________________________
Copyright © 2005 Porter-Cable Corporation
Part No. 903548 - 01-13-05
Download from Www.Somanuals.com. All Manuals Search And Download.
SAFETY GUIDELINES - DEFINITIONS
It is important for you to read and understand this manual. The
information it contains relates to protecting YOUR SAFETY and
PREVENTING PROBLEMS. The symbols below are used to help
you recognize this information.
indicates an imminently hazardous situation which, if not
avoided, will result in death or serious injury.
indicates a potentially hazardous situation which, if not
avoided,could result in death or serious injury.
indicates a potentially hazardous situation which, if not
avoided,may result in minor or moderate injury.
used without the safety alert symbol indicates potentially
hazardous situation which, if not avoided, may result in
property damage.
CALIFORNIA PROPOSITION 65
Some dust created by power sanding, sawing, grinding, drilling,
and other construction activities contains chemicals known (to the
State of California) to cause cancer, birth defects or other reproductive harm. Some
examples of these chemicals are:
●
●
●
lead from lead-based paints
crystalline silica from bricks and cement and other masonry products
arsenic and chromium from chemically-treated lumber
Your risk from these exposures varies, depending on how often you do this
type of work. To reduce your exposure to these chemicals: work in a well
ventilated area, and work with approved safety equipment, always wear
NIOSH/OSHA approved, properly fitting face mask or respirator when using
such tools.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
GENERAL SAFETY RULES
Read all instructions. Failure to follow all
instructions listed below may result in electric shock, fire and/or
serious injury. The term "power tool" in all of the warnings listed
below refers to your mains-operated (corded) power tool or
battery-operated (cordless) power tool.
SAVE THESE INSTRUCTIONS
1) Work area safety
a) Keep work area clean and well lit. Cluttered or dark areas invite
accidents.
b) Do not operate power tools in explosive atmospheres, such as in the
presence of flammable liquids, gases or dust. Power tools create
sparks which may ignite the dust or fumes.
c) Keep children and bystanders away while operating a power tool.
Distractions can cause you to lose control.
2) Electrical safety
a) Power tool plugs must match the outlet. Never modify the plug in any
way. Do not use any adapter plugs with earthed (grounded) power
tools. Unmodified plugs and matching outlets will reduce risk of electric
shock.
b) Avoid body contact with earthed or grounded surfaces such as
pipes, radiators, ranges and refrigerators. There is an increased risk of
electric shock if your body is earthed or grounded.
c) Do not expose power tools to rain or wet conditions. Water entering a
power tool will increase the risk of electric shock.
d) Do not abuse the cord. Never use the cord for carrying, pulling or
unplugging the power tool. Keep cord away from heat, oil, sharp
edges or moving parts. Damaged or entangled cords increase the risk
of electric shock.
e) When operating a power tool outdoors, use an extension cord
suitable for outdoor use. Use of a cord suitable for outdoor use reduces
the risk of electric shock.
3) Personal safety
a) Stay alert, watch what you are doing and use common sense when
operating a power tool. Do not use a power tool while you are tired
or under the influence of drugs, alcohol or medication. A moment of
inattention while operating power tools may result in serious personal
injury.
b) Use safety equipment. Always wear eye protection. Safety equipment
such as dust mask, non-skid safety shoes, hard hat, or hearing
protection used for appropriate conditions will reduce personal injuries.
c) Avoid accidental starting. Ensure the switch is in the off-position
before plugging in. Carrying power tools with your finger on the switch
or plugging in power tools that have the switch on invites accidents.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
continued
GENERAL SAFETY RULES
d) Remove any adjusting key or wrench before turning the power tool
on. A wrench or a key left attached to a rotating part of the power tool
may result in personal injury.
e) Do not overreach. Keep proper footing and balance at all times. This
enables better control of the power tool in unexpected situations.
f) Dress properly. Do not wear loose clothing or jewelry. Keep your
hair, clothing and gloves away from moving parts. Loose clothes,
jewelry or long hair can be caught in moving parts.
g) If devices are provided for the connection of dust extraction and
collection facilities, ensure these are connected and properly used.
Use of these devices can reduce dust-related hazards.
4) Power tool use and care
a) Do not force the power tool. Use the correct power tool for your
application. The correct power tool will do the job better and safer at the
rate for which it was designed.
b) Do not use the power tool if the switch does not turn it on and off.
Any power tool that cannot be controlled with the switch is dangerous
and must be repaired.
c) Disconnect the plug from the power source before making any
adjustments, changing accessories, or storing power tools. Such
preventive safety measures reduce the risk of starting the power tool
accidentally.
d) Store idle power tools out of the reach of children and do not allow
persons unfamiliar with the power tool or these instructions to
operate the power tool. Power tools are dangerous in the hands of
untrained users.
e) Maintain power tools. Check for misalignment or binding of moving
parts, breakage of parts and any other condition that may affect the
power tools operation. If damaged, have the power tool repaired
before use. Many accidents are caused by poorly maintained power
tools.
f) Keep cutting tools sharp and clean. Properly maintained cutting tools
with sharp cutting edges are less likely to bind and are easier to control.
g) Use the power tool, accessories and tool bits etc., in accordance
with these instructions and in the manner intended for the
particular type of power tool, taking into account the working
conditions and the work to be performed. Use of the power tool for
operations different from those intended could result in a hazardous
situation.
5) Service
a) Have your power tool serviced by a qualified repair person using only
identical replacement parts. This will ensure that the safety of the
power tool is maintained.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
ADDITIONAL SPECIFIC SAFETY RULES
1. Hold power tool by insulated gripping surfaces when performing an
operation where the cutting tool may contact hidden wiring or its own
cord. Contact with a "live" wire will make exposed metal parts of the tool
"live" and shock the operator.
2. Use clamps or other practical way to secure and support the
workpiece to a stable platform. Holding the work by hand or against your
body is unstable and may lead to loss of control.
3. Keep blades sharp. Sharp blades will do the job better and safer.
4. Keep hands away from cutting area. When sawing never reach
underneath or behind the material being cut for any reason.
5. When you have finished a cut be careful not to come into contact with
the blade. Turn off the motor immediately.
6.
Exercise extreme caution when blind cutting. Be certain
that there are no foreign objects such as electrical wire, conduit, plumbing
pipes, etc., that may come into contact with the blade.
7. Wear eye and hearing protection. Always use safety glasses. Everyday
eyeglasses are NOT safety glasses. USE CERTIFIED SAFETY EQUIPMENT.
Eye protection equipment should comply with ANSI Z87.1 standards.
Hearing equipment should comply with ANSI S3.19 standards.
8.
Use of this tool can generate and disburse dust or other
airborne particles, including wood dust, crystalline silica dust and
asbestos dust. Direct particles away from face and body. Always operate
tool in well ventilated area and provide for proper dust removal. Use dust
collection system wherever possible. Exposure to the dust may cause
serious and permanent respiratory or other injury, including silicosis (a
serious lung disease), cancer, and death. Avoid breathing the dust, and
avoid prolonged contact with dust. Allowing dust to get into your mouth or
eyes, or lay on your skin may promote absorption of harmful material.
Always use properly fitting NIOSH/OSHA approved respiratory protection
appropriate for the dust exposure, and wash exposed areas with soap and
water.
SAVE THESE INSTRUCTIONS!
6
Download from Www.Somanuals.com. All Manuals Search And Download.
SYMBOL
DEFINITION
........................ volts
V
A
........................ amperes
........................ hertz
........................ watts
........................ kilowatts
........................ farads
........................ microfarads
........................ litres
Hz
W
kW
F
µF
l
g
........................ grams
........................ kilograms
........................ bars
........................ pascals
........................ hours
........................ minutes
........................ seconds
........................ no-load speed
kg
bar
Pa
h
min
s
n0
…/min or …min 1 ......... Revolutions or reciprocations per minute
-
or d.c. ................ direct current
or a.c. ................ alternating current
2
........................ two-phase alternating current
2N
3
........................ two-phase alternating current with neutral
........................ three-phase alternating current
3N
........................ three-phase alternating current with neutral
........................ rated current of the appropriate fuse-link in amperes
........................ time-lag miniature fuse-link where X is the symbol
for the time/current characteristic, as given in IEC 60127
........................ protective earth
........................ class II tool
........................ IP symbol
IPXX
SAVE THESE INSTRUCTIONS!
7
Download from Www.Somanuals.com. All Manuals Search And Download.
MOTOR
Many Porter-Cable tools will operate on either D.C., or single phase 25 to 60
cycle A.C. current and voltage within plus or minus 5 percent of that shown on
the specification plate on the tool. Several models, however, are designed for
A.C. current only. Refer to the specification plate on your tool for proper voltage
and current rating.
Do not operate your tool on a current on which the
voltage is not within correct limits. Do not operate tools rated A.C.
only on D.C. current. To do so may seriously damage the tool.
EXTENSION CORD SELECTION
If an extension cord is used, make sure the conductor size is large enough to
prevent excessive voltage drop which will cause loss of power and possible
motor damage. A table of recommended extension cord sizes will be found in
this section. This table is based on limiting line voltage drop to 5 volts (10 volts
for 230 volts) at 150% of rated amperes.
If an extension cord is to be used outdoors, it must be marked with the suffix W-
A or W following the cord type designation. For example – SJTW-A to indicate it
is acceptable for outdoor use.
RECOMMENDED EXTENSION CORD SIZES FOR USE WITH PORTABLE ELECTRIC TOOLS
Length of Cord in Feet
115V
230V
25 Ft.
50 Ft.
50 Ft.
100 Ft. 150 Ft. 200 Ft.
250 Ft. 300 Ft.
500 Ft. 600 Ft.
400 Ft. 500 Ft.
800 Ft. 1000 Ft.
100 Ft. 200 Ft. 300 Ft. 400 Ft.
0-2
2-3
18
18
18
18
18
18
18
16
16
16
14
14
18
18
18
18
16
16
14
14
12
12
12
12
18
16
16
14
14
12
12
10
10
10
8
16
14
14
12
12
10
10
8
16
14
12
12
10
10
8
14
12
12
10
10
8
14
12
10
10
8
12
10
10
8
12
10
8
3-4
4-5
8
5-6
8
6
6-8
6
6
6
8-10
10-12
12-14
14-16
16-18
18-20
8
6
6
4
8
6
6
4
4
8
6
6
6
4
2
8
6
6
4
4
2
8
6
4
4
2
2
8
6
6
4
4
2
2
SAVE THESE INSTRUCTIONS!
CARTON CONTENTS
1) Saw
2) Instruction Manual
3) Replacement Parts List
4) Combination Package
8
Download from Www.Somanuals.com. All Manuals Search And Download.
FUNCTIONAL DESCRIPTION
FOREWORD
Model 548 Bayonet Saw is designed for cutting materials of the following
MAXIMUM thickness: Wood 21/2", Aluminum 3/4", Steel 1/4".
SELECTING THE BLADE
To obtain best results with your Porter-Cable bayonet saw, it is important
that you use the right blade for the job. You will not only get better
performance, but your blades will last longer and a smoother cut will result.
ASSEMBLY
NOTE: This tool is shipped completely assembled. No assembly time or
tools are required.
INSTALLING THE BLADE
DISCONNECT TOOL FROM POWER SOURCE.
The blade screw and nut lock the blade in the holder. The nut has a recess
on one side and the blade screw has a shoulder that fits within this recess.
NOTE: To avoid pinching and breakage of the blade make sure the recess in
the nut faces the screw head and the shoulder on the screw projects slightly
into this recess before installing the blade. Insert the blade into the blade
holder and over the screw, see Fig. 1. Use the wrench furnished with your
saw and apply only enough torque to firmly hold the blade.
NOTE: Do not over tighten as damage to the screw or nut may result.
Fig.` 1
OPERATION
TO START AND STOP SAW
1. Make sure power circuit voltage is the same as shown on the
specification plate on the saw. Connect saw to power circuit.
2. Squeeze switch trigger (A) Fig. 2 to start motor. Release trigger to stop
motor. This saw has a variable speed switch, as the switch trigger is
squeezed, the speed of the saw blade increases.
3. Lock Button – A lock button (B) Fig. 2, is provided to keep the saw
running at the fastest speed without holding the switch trigger “ON”. To
lock the switch trigger on, squeeze the trigger as far as it will go and
push in the lock button and release trigger.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
To unlock the lock button, squeeze trigger allowing lock button free to spring
out, and release.
B
A
Fig. 2
BASE INSERT
Two base inserts, like the one shown in Fig. 3, are available to reduce
splintering the top fibers of plywood and other splinter-prone materials. One
1
insert has a short center slot for use with tapered tooth blades up to /4"
wide. The other insert has a long center slot for use with tapered tooth
3
blades that are /8" wide. DO NOT USE BASE INSERTS WITH ANY TYPE
BLADES OTHER THAN THOSE DESCRIBED. TO DO SO, MAY RESULT IN
BLADE BREAKAGE OR DAMAGE TO THE SAW.
To install insert, remove saw blade from Bayonet Saw and locate insert in
the throat of the saw base with the slot forward and the beveled side of the
slot up. Install appropriate blade as outlined in section INSTALLING THE
BLADE with the blade body in the slot of the insert.
When cutting plywood with the base insert installed in the saw, it is not
necessary for the good or finished side of the material to be down as would
be the practice with an ordinary jig saw. The small teeth of the blade and
speed of the saw in conjunction with the base insert will prevent splintering
or chipping of the top surface.
Fig.` 3
PLUNGE CUTTING
When cutting into a wall avoid contact with all exposed
metal on the tool to prevent electrical shock hazard resulting from
accidentally cutting into a live wire. HOLD SAW AS ILLUSTRATED IN
FIG. 4.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
One of the distinctive and important features of the Porter-Cable bayonet
saw is the ability to start the cut (in wood only) within an area without making
drilled holes first. This is especially important when making cut-outs for
electric outlets in finished walls, openings in cabinet tops for sinks and
openings for plumbing fixtures.
First, measure the area to be cut out and mark it clearly with a pencil, chalk
or scriber. Choose a convenient starting point and hold the bayonet saw
over the point and inside the line of waste. Tip the machine forward until the
front edge of the base rests firmly on the surface of the material with the tip
of the blade clear of the work surface, as shown in Fig. 4. Turn motor “ON”
and slowly lower the back of the machine allowing blade to bite into surface
of work. Do not move the machine forward until the base is fully seated on
the surface of the work. Now, guide the cutting along the inside of the
marked area. If sharp corners are desired cut right up to the corner of the
marked edge. Stop and back up just a bit, start the turn and cut along the
side. Do the same at each corner until you end up where you started. Then,
go back and cut into each corner from the opposite direction. The base of
the machine is wide enough so you will have a solid guiding surface on
either side of the cut.
Fig.` 4
USING THE JIG SAW
First, secure the material in a bench vise or with clamps to the work table.
This is especially important when sawing small pieces or thin material. As
the work progresses in scroll or curved cut-out pieces, the material can be
re-adjusted to accommodate the movement of the saw. If the work is large
enough, it may be held only by hand across saw horses or some other rigid
support. The saw cuts freely with only light forward feed pressure on the
tool. Forcing the saw will not cause it to cut faster. Be careful not to twist the
saw while making the cut. This will cause blade breakage. To start the cut,
secure the work, mark the line of cut clearly, place forward edge of saw base
on edge of the material, start motor and when motor is up to desired speed,
move blade into the work.
NOTE: Because of the variable speed feature, trial cuts at varying
speeds should be made on scrap material to determine the cutting
speed for the most desirable results.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
DO NOT FORCE, LET THE SAW DO THE WORK. Move saw forward only
fast enough to keep blade cutting. If cutting becomes difficult, the blade is
dull and should be changed at once. A dull blade not only makes cutting
more difficult but also overburdens the motor. You will find the open throat
and clear forward edge of the saw base make it easy to follow the line.
LUBRICATION
Although all Porter-Cable tools have been thoroughly lubricated with a
sufficient amount of high grade lubricant at the time of manufacture, it is
recommended that the oil level in the gear chamber be checked before
using your saw and periodically thereafter as follows:
DISCONNECT TOOL FROM POWER SOURCE.
1. Remove saw blade and set machine on a level surface.
2. Remove oil plug from front of machine.
3. Gear lubricant should be level with the bottom of the oil plug hole, but
should not run out. If this condition does not exist, tip machine up and
add a small amount of Porter-Cable lubricant until it is even with the
bottom of the hole.
4. NOTE: DO NOT OVERFILL. If you do, the pressure created by the
pumping action of the gears may force lubricant through seals and into
motor and mechanism chamber causing damage to the machine.
5. To change lubricant in the mechanism housing it is necessary to
dismantle the tool. This operation should only be performed by a
AUTHORIZED PORTER-CABLE SERVICE STATION or a PORTER-
CABLE•DELTA FACTORY SERVICE CENTER.
However, the lubricant may be checked as follows:
A. Remove all traces of the sawdust and grime from around the gear
housing and blade holder to eliminate the possibility of
contaminating the mechanism lubricant.
B. Remove four gear housing cover screws located around the knob
on the left side of the machine.
C. Lift off cover and gasket being careful not to damage the gasket.
D. There should be a thin layer of lubricant around the blade holder. If
this lubricant is contaminated, take your saw to an authorized
Porter-Cable Service Station for a thorough cleaning and lubrication.
If lubricant is needed, brush a thin coat of Porter-Cable lubricant on
the blade holder. NOTE: An excessive amount of lubricant may leak
through the blade holder dust seal and spatter on material being
cut.
E. Replace gasket and gear housing cover and tighten four screws
securely.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
TROUBLESHOOTING
list of service centers or call the Porter-Cable help line at 1-800-487-8665.
MAINTENANCE
KEEP TOOL CLEAN
Periodically blow out all air passages with dry compressed air. All plastic parts
should be cleaned with a soft damp cloth. NEVER use solvents to clean plastic
parts. They could possibly dissolve or otherwise damage the material.
Wear ANSI Z87.1 safety glasses while using compressed air.
FAILURE TO START
Should your tool fail to start, check to make sure the prongs on the cord plug are
making good contact in the outlet. Also, check for blown fuses or open circuit
breakers in the line.
BRUSH INSPECTION (If applicable)
For your continued safety and electrical protection, brush inspection and
replacement on this tool should ONLY be performed by an AUTHORIZED
PORTER-CABLE SERVICE STATION or a PORTER-CABLE•DELTA FACTORY
SERVICE CENTER.
At approximately 100 hours of use, take or send your tool to your nearest
authorized Porter-Cable Service Station to be thoroughly cleaned and inspected.
Have worn parts replaced and lubricated with fresh lubricant. Have new brushes
installed, and test the tool for performance.
Any loss of power before the above maintenance check may indicate the need
for immediate servicing of your tool. DO NOT CONTINUE TO OPERATE TOOL
UNDER THIS CONDITION. If proper operating voltage is present, return your
tool to the service station for immediate service.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
SERVICE
REPLACEMENT PARTS
When servicing use only identical replacement parts. For a service parts list or to
learn more about Porter-Cable visit our website at www.porter-cable.com
SERVICE AND REPAIRS
All quality tools will eventually require servicing, or replacement of parts due to
wear from normal use. For assistance with your tool, visit our website at
www.porter-cable.com for a list of service centers or call the Customer Care
Department at 1-800-487-8665. All repairs made by our service centers are fully
guaranteed against defective material and workmanship. We cannot guarantee
repairs made or attempted by others.
Should you have any questions about your tool, feel free to write us at any time.
In any communications, please give all information shown on the nameplate of
your tool (model number, type, serial number, etc.).
ACCESSORIES
A complete line of accessories is available from your Porter-Cable•Delta
Supplier, Porter-Cable•Delta Factory Service Centers, and Porter-Cable
Authorized Service Stations. Please visit our Web Site www.porter-cable.com
for a catalog or for the name of your nearest supplier.
Since accessories other than those offered by
Porter-Cable•Delta have not been tested with this product, use of
such accessories could be hazardous. For safest operation, only
Porter-Cable•Delta recommended accessories should be used
with this product.
WARRANTY
PORTER-CABLE LIMITED
ONE YEAR WARRANTY
Porter-Cable warrants its Professional Power Tools for a period of one year from the date of original
purchase. We will repair or replace at our option, any part or parts of the product and accessories
covered under this warranty which, after examination, proves to be defective in workmanship or
material during the warranty period. For repair or replacement return the complete tool or accessory,
transportation prepaid, to your nearest Porter-Cable Service Center or Authorized Service Station.
Proof of purchase may be required. This warranty does not apply to repair or replacement required
due to misuse, abuse, normal wear and tear or repairs attempted or made by other than our Service
Centers or Authorized Service Stations.
ANY IMPLIED WARRANTY, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE, WILL LAST ONLY FOR ONE (1) YEAR FROM THE DATE
OF PURCHASE.
To obtain information on warranty performance please write to: PORTER-CABLE CORPORATION,
4825 Highway 45 North, Jackson, Tennessee 38305; Attention: Product Service. THE FOREGOING
OBLIGATION IS PORTER-CABLE’S SOLE LIABILITY UNDER THIS OR ANY IMPLIED WARRANTY
AND UNDER NO CIRCUMSTANCES SHALL PORTER-CABLE BE LIABLE FOR ANY INCIDENTAL
OR CONSEQUENTIAL DAMAGES. Some states do not allow limitations on how long an implied
warranty lasts or the exclusion or limitation of incidental or consequential damages, so the above
limitation or exclusion may not apply to you.
This warranty gives you specific legal rights and you may also have other legal rights which vary
from state to state.
14
Download from Www.Somanuals.com. All Manuals Search And Download.
PORTER-CABLE • DELTA SERVICE CENTERS
(CENTROS DE SERVICIO DE PORTER-CABLE • DELTA)
(CENTRE DE SERVICE PORTER-CABLE • DELTA)
Parts and Repair Service for Porter-Cable
(Obtenga Refaccion de Partes o Servicio para su Herramienta en los Siguientes Centros de Porter-Cable
(Locations où vous trouverez les pièces de rechange nécessaires ainsi qu’un service d’entretien)
•
Delta Power Tools are Available at These Locations
•
Delta)
Cleveland 44125
8001 Sweet Valley Drive
Unit #19
Phone: (216) 447-9030
Fax: (216) 447-3097
ARIZONA
MINNESOTA
Minneapolis 55429
5522 Lakeland Avenue North
Phone: (763) 561-9080
Fax: (763) 561-0653
GEORGIA
Tempe 85282 (Phoenix)
2400 West Southern Avenue
Suite 105
Phone: (602) 437-1200
Fax: (602) 437-2200
Forest Park 30297 (Atlanta)
5442 Frontage Road,
Suite 112
Phone: (404) 608-0006
Fax: (404) 608-1123
OREGON
MISSOURI
Portland 97230
CALIFORNIA
North Kansas City 64116
1141 Swift Avenue
Phone: (816) 221-2070
Fax: (816) 221-2897
ILLINOIS
4916 NE 122 nd Ave.
Phone: (503) 252-0107
Fax: (503) 252-2123
Ontario 91761 (Los Angeles)
3949A East Guasti Road
Phone: (909) 390-5555
Fax: (909) 390-5554
Addison 60101 (Chicago)
400 South Rohlwing Rd.
Phone: (630) 424-8805
Fax: (630) 424-8895
PENNSYLVANIA
St. Louis 63119
Willow Grove 19090 (Philadelphia)
520 North York Road
Phone: (215) 658-1430
Fax: (215) 658-1433
7574 Watson Road
Phone: (314) 968-8950
Fax: (314) 968-2790
Woodridge 60517 (Chicago)
2033 West 75th Street
Phone: (630) 910-9200
Fax: (630) 910-0360
San Diego 92111
7638 Clairemont Blvd.
Phone: (858) 277-9595
Fax: (858) 277-9696
NEW YORK
TEXAS
Flushing 11365-1595 (N.Y.C.)
175-25 Horace Harding Expwy.
Phone: (718) 225-2040
Fax: (718) 423-9619
MARYLAND
San Leandro 94577 (Oakland)
3039 Teagarden Street
Phone: (510) 357-9762
Fax: (510) 357-7939
Carrollton 75006 (Dallas)
1300 Interstate 35 N, Suite 112
Phone: (972) 446-2996
Fax: (972) 446-8157
Elkridge 21075 (Baltimore)
7397-102 Washington Blvd.
Phone: (410) 799-9394
Fax: (410) 799-9398
NORTH CAROLINA
Charlotte 28270
9129 Monroe Road, Suite 115
Phone: (704) 841-1176
Fax: (704) 708-4625
COLORADO
Houston 77043
4321 Sam Houston Parkway, West
Suite 180
Phone: (713) 983-9910
Fax: (713) 983-6645
MASSACHUSETTS
Arvada 80003 (Denver)
8175 Sheridan Blvd., Unit S
Phone: (303) 487-1809
Fax: (303) 487-1868
Franklin 02038 (Boston)
Franklin Industrial Park
101E Constitution Blvd.
Phone: (508) 520-8802
Fax: (508) 528-8089
OHIO
FLORIDA
WASHINGTON
Columbus 43214
4560 Indianola Avenue
Phone: (614) 263-0929
Fax: (614) 263-1238
Davie 33314 (Miami)
4343 South State Rd. 7 (441)
Unit #107
Phone: (954) 321-6635
Fax: (954) 321-6638
Auburn 98001(Seattle)
3320 West Valley HWY, North
Building D, Suite 111
Phone: (253) 333-8353
Fax: (253) 333-9613
MICHIGAN
Madison Heights 48071 (Detroit)
30475 Stephenson Highway
Phone: (248) 597-5000
Fax: (248) 597-5004
Tampa 33609
4538 W. Kennedy Boulevard
Phone: (813) 877-9585
Fax: (813) 289-7948
Authorized Service Stations are located in many large cities. Telephone 800-487-8665 or 731-541-6042 for assistance locating one. Parts and
accessories for Porter-Cable Delta products should be obtained by contacting any Porter-Cable Delta Distributor, Authorized Service
Center, or Porter-Cable Delta Factory Service Center. If you do not have access to any of these, call 888-848-5175 and you will be directed to
the nearest Porter-Cable Delta Factory Service Center. Las Estaciones de Servicio Autorizadas están ubicadas en muchas grandes ciudades.
Llame al 800-487-8665 ó al 731-541-6042 para obtener asistencia a fin de localizar una. Las piezas y los accesorios para los productos Porter-
Cable Delta deben obtenerse poniéndose en contacto con cualquier distribuidor Porter-Cable Delta, Centro de Servicio Autorizado o Centro
de Servicio de Fábrica Porter-Cable Delta. Si no tiene acceso a ninguna de estas opciones, llame al 888-848-5175 y le dirigirán al Centro de
Servicio de Fábrica Porter-Cable Delta más cercano. Des centres de service agréés sont situés dans beaucoup de grandes villes. Appelez au
800-487-8665 ou au 731-541-6042 pour obtenir de l’aide pour en repérer un. Pour obtenir des pièces et accessoires pour les produits Porter-
•
•
•
•
•
•
•
•
Cable
•
Delta, s’adresser à tout distributeur Porter-Cable
•
Delta, centre de service agréé ou centre de service d’usine Porter-Cable
•
Delta. Si
vous n’avez accès à aucun de ces centres, appeler le 888-848-5175 et on vous dirigera vers le centre de service d’usine Porter-Cable
•
Delta le
plus proche.
CANADIAN PORTER-CABLE • DELTA SERVICE CENTERS
QUÉBEC
ALBERTA
MANITOBA
1515 Ave.
Bay 6, 2520-23rd St. N.E.
Calgary, Alberta
T2E 8L2
1699 Dublin Avenue
Winnipeg, Manitoba
R3H 0H2
St-Jean Baptiste, Suite 160
Québec, P.Q.
G2E 5E2
Phone: (418) 877-7112
Fax: (418) 877-7123
Phone: (403) 735-6166
Fax: (403) 735-6144
Phone: (204) 633-9259
Fax: (204) 632-1976
BRITISH COLUMBIA
8520 Baxter Place
Burnaby, B.C.
V5A 4T8
Phone: (604) 420-0102
Fax: (604) 420-3522
ONTARIO
1447, Begin
St-Laurent, (Mtl), P.Q.
H4R 1V8
Phone: (514) 336-8772
Fax: (514) 336-3505
505 Southgate Drive
Guelph, Ontario
N1H 6M7
Phone: (519) 767-4132
Fax: (519) 767-4131
The following are trademarks of PORTER-CABLE
•
DELTA (Las siguientes son marcas registradas de PORTER-CABLE
•
DELTA S.A.) (Les
marques suivantes sont des marques de fabriquant de la PORTER-CABLE
•
DELTA): Auto-Set®, BAMMER®, B.O.S.S.®, Builder’s Saw®,
Contractor’s Saw®, Contractor’s Saw II™, Delta®, DELTACRAFT®, DELTAGRAM™, Delta Series 2000™, DURATRONIC™, Emc²™, FLEX®, Flying
Chips™, FRAME SAW®, Grip Vac™, Homecraft®, INNOVATION THAT WORKS®, Jet-Lock®, JETSTREAM®, ‘kickstand®, LASERLOC®, MICRO-
SET®, Micro-Set®, MIDI LATHE®, MORTEN™, NETWORK™, OMNIJIG®, POCKET CUTTER®, PORTA-BAND®, PORTA-PLANE®, PORTER-
CABLE®&(design), PORTER-CABLE®PROFESSIONAL POWER TOOLS, PORTER-CABLE REDEFINING PERFORMANCE™, Posi-Matic®, Q-
3®&(design), QUICKSAND®&(design), QUICKSET™, QUICKSET II®, QUICKSET PLUS™, RIPTIDE™&(design), SAFE GUARD II®, SAFE-LOC®,
Sanding Center®, SANDTRAP®&(design), SAW BOSS®, Sawbuck™, Sidekick®, SPEED-BLOC®, SPEEDMATIC®, SPEEDTRONIC®, STAIR EASE®,
The American Woodshop®&(design), The Lumber Company®&(design), THE PROFESSIONAL EDGE®, THE PROFESSIONAL SELECT®, THIN-
LINE™, TIGER®, TIGER CUB®, TIGER SAW®, TORQBUSTER®, TORQ-BUSTER®, TRU-MATCH™, TWIN-LITE®, UNIGUARD®, Unifence®,
UNIFEEDER™, Unihead®, Uniplane™, Unirip®, Unisaw®, Univise®, Versa-Feeder®, VERSA-PLANE® , WHISPER SERIES®,
WOODWORKER’S CHOICE™.
Trademarks noted with ™ and ® are registered in the United States Patent and Trademark Office and may also be registered in other countries.
Las Marcas Registradas con el signo de ™ y ® son registradas por la Oficina de Registros y Patentes de los Estados Unidos y también pueden
estar registradas en otros países. Marques déposées, indiquées par la lettre ™ et ®, sont déposées au Bureau des brevets d’invention et
marques déposées aux Etats-Unis et pourraient être déposées aux autres pays.
PC7.2-0105-164
Download from Www.Somanuals.com. All Manuals Search And Download.
|