SAFETY GUIDELINES - DEFINITIONS  
It is important for you to read and understand this manual. The  
information it contains relates to protecting YOUR SAFETY and  
PREVENTING PROBLEMS. The symbols below are used to help  
you recognize this information.  
indicates an imminently hazardous situation which, if not  
avoided, will result in death or serious injury.  
indicates a potentially hazardous situation which, if not  
avoided,could result in death or serious injury.  
indicates a potentially hazardous situation which, if not  
avoided,may result in minor or moderate injury.  
used without the safety alert symbol indicates potentially  
hazardous situation which, if not avoided, may result in  
property damage.  
CALIFORNIA PROPOSITION 65  
Some dust created by power sanding, sawing, grinding, drilling,  
and other construction activities contains chemicals known (to the  
State of California) to cause cancer, birth defects or other reproductive harm. Some  
examples of these chemicals are:  
lead from lead-based paints  
crystalline silica from bricks and cement and other masonry products  
arsenic and chromium from chemically-treated lumber  
Your risk from these exposures varies, depending on how often you do this  
type of work. To reduce your exposure to these chemicals: work in a well  
ventilated area, and work with approved safety equipment, always wear  
NIOSH/OSHA approved, properly fitting face mask or respirator when using  
such tools.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
GENERAL SAFETY RULES  
Read all instructions. Failure to follow all  
instructions listed below may result in electric shock, fire and/or  
serious injury. The term "power tool" in all of the warnings listed  
below refers to your mains-operated (corded) power tool or  
battery-operated (cordless) power tool.  
SAVE THESE INSTRUCTIONS  
1) Work area safety  
a) Keep work area clean and well lit. Cluttered or dark areas invite  
accidents.  
b) Do not operate power tools in explosive atmospheres, such as in the  
presence of flammable liquids, gases or dust. Power tools create  
sparks which may ignite the dust or fumes.  
c) Keep children and bystanders away while operating a power tool.  
Distractions can cause you to lose control.  
2) Electrical safety  
a) Power tool plugs must match the outlet. Never modify the plug in any  
way. Do not use any adapter plugs with earthed (grounded) power  
tools. Unmodified plugs and matching outlets will reduce risk of electric  
shock.  
b) Avoid body contact with earthed or grounded surfaces such as  
pipes, radiators, ranges and refrigerators. There is an increased risk of  
electric shock if your body is earthed or grounded.  
c) Do not expose power tools to rain or wet conditions. Water entering a  
power tool will increase the risk of electric shock.  
d) Do not abuse the cord. Never use the cord for carrying, pulling or  
unplugging the power tool. Keep cord away from heat, oil, sharp  
edges or moving parts. Damaged or entangled cords increase the risk  
of electric shock.  
e) When operating a power tool outdoors, use an extension cord  
suitable for outdoor use. Use of a cord suitable for outdoor use reduces  
the risk of electric shock.  
3) Personal safety  
a) Stay alert, watch what you are doing and use common sense when  
operating a power tool. Do not use a power tool while you are tired  
or under the influence of drugs, alcohol or medication. A moment of  
inattention while operating power tools may result in serious personal  
injury.  
b) Use safety equipment. Always wear eye protection. Safety equipment  
such as dust mask, non-skid safety shoes, hard hat, or hearing  
protection used for appropriate conditions will reduce personal injuries.  
c) Avoid accidental starting. Ensure the switch is in the off-position  
before plugging in. Carrying power tools with your finger on the switch  
or plugging in power tools that have the switch on invites accidents.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
continued  
GENERAL SAFETY RULES  
d) Remove any adjusting key or wrench before turning the power tool  
on. A wrench or a key left attached to a rotating part of the power tool  
may result in personal injury.  
e) Do not overreach. Keep proper footing and balance at all times. This  
enables better control of the power tool in unexpected situations.  
f) Dress properly. Do not wear loose clothing or jewelry. Keep your  
hair, clothing and gloves away from moving parts. Loose clothes,  
jewelry or long hair can be caught in moving parts.  
g) If devices are provided for the connection of dust extraction and  
collection facilities, ensure these are connected and properly used.  
Use of these devices can reduce dust-related hazards.  
4) Power tool use and care  
a) Do not force the power tool. Use the correct power tool for your  
application. The correct power tool will do the job better and safer at the  
rate for which it was designed.  
b) Do not use the power tool if the switch does not turn it on and off.  
Any power tool that cannot be controlled with the switch is dangerous  
and must be repaired.  
c) Disconnect the plug from the power source before making any  
adjustments, changing accessories, or storing power tools. Such  
preventive safety measures reduce the risk of starting the power tool  
accidentally.  
d) Store idle power tools out of the reach of children and do not allow  
persons unfamiliar with the power tool or these instructions to  
operate the power tool. Power tools are dangerous in the hands of  
untrained users.  
e) Maintain power tools. Check for misalignment or binding of moving  
parts, breakage of parts and any other condition that may affect the  
power tools operation. If damaged, have the power tool repaired  
before use. Many accidents are caused by poorly maintained power  
tools.  
f) Keep cutting tools sharp and clean. Properly maintained cutting tools  
with sharp cutting edges are less likely to bind and are easier to control.  
g) Use the power tool, accessories and tool bits etc., in accordance  
with these instructions and in the manner intended for the  
particular type of power tool, taking into account the working  
conditions and the work to be performed. Use of the power tool for  
operations different from those intended could result in a hazardous  
situation.  
5) Service  
a) Have your power tool serviced by a qualified repair person using only  
identical replacement parts. This will ensure that the safety of the  
power tool is maintained.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
ADDITIONAL SPECIFIC SAFETY RULES  
1. Hold power tools by insulated gripping surfaces when performing an  
operation where the cutting tool may contact hidden wiring or its own  
cord. Contact with a "live" wire will make exposed metal parts of the tool  
"live" and shock the operator.  
2. Sanding of lead-based paint is not recommended. Lead-based paint  
should only be removed by a professional.  
3. Always maintain a firm grip on the sander handles with both hands to  
prevent loss of control.  
4. Do not operate sander without all guards and covers securely in place.  
5. Wear eye and hearing protection. Always use safety glasses. Everyday  
eyeglasses are NOT safety glasses. USE CERTIFIED SAFETY EQUIPMENT.  
Eye protection equipment should comply with ANSI Z87.1 standards.  
Hearing equipment should comply with ANSI S3.19 standards.  
6.  
Use of this tool can generate and disburse dust or other  
airborne particles, including wood dust, crystalline silica dust and  
asbestos dust. Direct particles away from face and body. Always operate  
tool in well ventilated area and provide for proper dust removal. Use dust  
collection system wherever possible. Exposure to the dust may cause  
serious and permanent respiratory or other injury, including silicosis (a  
serious lung disease), cancer, and death. Avoid breathing the dust, and  
avoid prolonged contact with dust. Allowing dust to get into your mouth or  
eyes, or lay on your skin may promote absorption of harmful material.  
Always use properly fitting NIOSH/OSHA approved respiratory protection  
appropriate for the dust exposure, and wash exposed areas with soap and  
water.  
SAVE THESE INSTRUCTIONS!  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
SYMBOL  
DEFINITION  
........................ volts  
V
A
........................ amperes  
........................ hertz  
........................ watts  
........................ kilowatts  
........................ farads  
........................ microfarads  
........................ litres  
Hz  
W
kW  
F
µF  
l
g
........................ grams  
........................ kilograms  
........................ bars  
........................ pascals  
........................ hours  
........................ minutes  
........................ seconds  
........................ no-load speed  
kg  
bar  
Pa  
h
min  
s
n0  
…/min or …min 1 ......... Revolutions or reciprocations per minute  
-
or d.c. ................ direct current  
or a.c. ................ alternating current  
2
........................ two-phase alternating current  
2N  
3
........................ two-phase alternating current with neutral  
........................ three-phase alternating current  
3N  
........................ three-phase alternating current with neutral  
........................ rated current of the appropriate fuse-link in amperes  
........................ time-lag miniature fuse-link where X is the symbol  
for the time/current characteristic, as given in IEC 60127  
........................ protective earth  
........................ class II tool  
........................ IP symbol  
IPXX  
SAVE THESE INSTRUCTIONS!  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
ADDITIONAL SAFETY RULES FOR PAINT REMOVAL  
Extreme care should be taken when removing paint. The  
peelings, residue, and vapors of paint may contain lead, which  
is poisonous. Exposure to even low levels of lead can cause  
irreversible brain and nervous system damage. Young and  
unborn children are particularly vulnerable.  
Before beginning any paint removal process you should determine whether the  
paint you are removing contains lead. This can be done by your local health  
department or by a professional who uses a paint analyzer to check for lead.  
Lead-based paint should only be removed by a professional.  
Persons removing paint should follow these guidelines:  
1. Keep the work area well ventilated. Open the windows and put an  
exhaust fan in one of them. Be sure the fan is moving air from inside to outside.  
2. Remove or cover any carpets, rugs, furniture, clothing, cooking  
utensils, and air ducts. Such preventive safety measures reduce the risk of  
exposure.  
3. Place drop cloths in the work area to catch any paint chips or peelings.  
Wear protective clothing such as extra work shirts, overalls and hats. Such  
preventive safety measures reduce the risk of exposure.  
4. Work in one room at a time. Furnishings should be removed or placed in  
the center of the room and covered. Work areas should be sealed off from the  
rest of the dwelling by sealing doorways with drop cloths.  
5. Children, pregnant, or potentially pregnant women and nursing mothers  
should not be present in the work area until the work is done and all  
cleanup is complete. Such preventive safety measures reduce the risk of  
injury.  
6. Wear a dust respirator or a dual filter (dust and fume) respirator mask  
which has been approved by the Occupational Safety and Health  
Administration (OSHA), the National Institute of Safety and Health (NIOSH),  
or the United States Bureau of Mines. These masks and replaceable filters are  
readily available at major hardware stores. Be sure the mask fits. Beards and  
facial hair may keep the masks from sealing properly. Change filters often.  
DISPOSABLE PAPER MASKS ARE NOT ADEQUATE.  
7. Keep food and drink out of the work area. Wash hands, arms, and face  
and rinse mouth before eating or drinking. Do not smoke or chew gum or  
tobacco in the work area.  
8. Clean up all removed paint and dust by wet mopping the floors. Use a  
wet cloth to clean all walls, sills and any other surfaces where paint or dust is  
clinging. DO NOT SWEEP, DRY DUST OR VACUUM. Use a high phosphate  
detergent or trisodium (TSP) to wash and mop areas.  
9. At the end of each work session, put the paint chips and debris in a  
double plastic bag, close it with tape or twist ties and dispose properly. Such  
preventive safety measures reduce the risk of exposure.  
10. Remove protective clothing and work shoes in the work area to avoid  
carrying dust into the rest of the dwelling. Wash work clothes separately. Wipe  
shoes off with a wet rag, then wash that rag with the work clothes. Wash hair and  
body thoroughly with soap and water.  
SAVE THESE INSTRUCTIONS!  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
MOTOR  
Many Porter-Cable tools will operate on either D.C., or single phase 25 to 60  
cycle A.C. current and voltage within plus or minus 5 percent of that shown on  
the specification plate on the tool. Several models, however, are designed for  
A.C. current only. Refer to the specification plate on your tool for proper voltage  
and current rating.  
Do not operate your tool on a current on which the  
voltage is not within correct limits. Do not operate tools rated A.C.  
only on D.C. current. To do so may seriously damage the tool.  
EXTENSION CORD SELECTION  
If an extension cord is used, make sure the conductor size is large enough to  
prevent excessive voltage drop which will cause loss of power and possible  
motor damage. A table of recommended extension cord sizes will be found in  
this section. This table is based on limiting line voltage drop to 5 volts (10 volts  
for 230 volts) at 150% of rated amperes.  
If an extension cord is to be used outdoors, it must be marked with the suffix W-  
A or W following the cord type designation. For example – SJTW-A to indicate it  
is acceptable for outdoor use.  
RECOMMENDED EXTENSION CORD SIZES FOR USE WITH PORTABLE ELECTRIC TOOLS  
Length of Cord in Feet  
115V  
230V  
25 Ft.  
50 Ft.  
50 Ft.  
100 Ft. 150 Ft. 200 Ft.  
250 Ft. 300 Ft.  
500 Ft. 600 Ft.  
400 Ft. 500 Ft.  
800 Ft. 1000 Ft.  
100 Ft. 200 Ft. 300 Ft. 400 Ft.  
0-2  
2-3  
18  
18  
18  
18  
18  
18  
18  
16  
16  
16  
14  
14  
18  
18  
18  
18  
16  
16  
14  
14  
12  
12  
12  
12  
18  
16  
16  
14  
14  
12  
12  
10  
10  
10  
8
16  
14  
14  
12  
12  
10  
10  
8
16  
14  
12  
12  
10  
10  
8
14  
12  
12  
10  
10  
8
14  
12  
10  
10  
8
12  
10  
10  
8
12  
10  
8
3-4  
4-5  
8
5-6  
8
6
6-8  
6
6
6
8-10  
10-12  
12-14  
14-16  
16-18  
18-20  
8
6
6
4
8
6
6
4
4
8
6
6
6
4
2
8
6
6
4
4
2
8
6
4
4
2
2
8
6
6
4
4
2
2
SAVE THESE INSTRUCTIONS!  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
CARTON CONTENTS  
* Sander  
* Standard sanding pad  
* Profile mounting plates  
* Set of 9 different sanding profiles  
* Assorted profile sanding sheets  
* Carrying case  
FUNCTIONAL DESCRIPTION  
FOREWORD  
The Porter-Cable Profile Sander provides an “in-line” sanding motion that  
permits sanding of corners, profiles, and other areas that are inaccessible to  
other power sanders.  
ASSEMBLY  
NOTE: This tool is shipped completely assembled. No assembly time or  
tools are required.  
OPERATION  
PREPARATION FOR SANDING  
NOTE: A wide variety of accessory pads, profile holders, and  
profiles is available to fit the Porter-Cable Profile Sander. Please  
refer to your Porter-Cable Catalog to determine which of these items  
are supplied as standard equipment with each particular Profile  
Sander Package. All of these items are available as accessories, and  
they may be used with any Porter-Cable Model 444 Profile Sander.  
SELECTING A PAD OR PROFILE MOUNTING PLATE  
Select the sanding pad or profile holder that best fits your application: Fig. 1.  
A
B
C
D
E
Fig. 1  
A. Diamond Pad for PSA Abrasives: The pointed tip of this pad is used for  
sanding into corners and intricately shaped areas. Precut PSA abrasives are  
used with this pad (Fig. 2).  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
B. Diamond Pad for Hook & Loop Abrasives: The pointed tip of this pad  
is used for sanding into corners and intricately shaped areas. Precut, Hook &  
Loop Abrasives with dust extraction holes are used with this pad. The  
optional 14449 dust wand (and an external vacuum source), can also be  
used with this pad to provide dust collection (Fig. 3).  
Fig. 2  
Fig. 3  
C. Single Profile Mounting Plate: This plate is used to mount any one of  
the profiles in a vertical position, centered under the Profile Sander (Fig. 4).  
Special PSA Abrasives are available in precut sheets or in rolls that can be  
cut-to-fit the various profiles.  
D. Angled Profile Mounting Plate: This plate is used to mount any one of  
the profiles at a 30° outward angle on either the right or left side of the tool.  
(Fig. 5) This plate permits the profiles to be used in areas that are  
inaccessible with the Single Profile Mounting Plate. Special PSA Abrasives  
are available in precut sheets or in rolls that can be cut-to-fit the various  
profiles.  
E. Offset “Shutter” Pad: This pad permits access to recessed surfaces,  
such as those found on louvered shutters. (Fig. 6) Special PSA Abrasives are  
available in rolls that can be cut-to-fit this pad.  
Fig. 6  
Fig. 5  
Fig. 4  
SELECTING A PROFILE  
Individual Profiles are available in three basic styles. Several sizes are  
available in each style (see a Porter-Cable Catalog for a complete listing).  
The three basic styles are:  
Convex Profiles Used to sand concave surfaces. Available in several  
sizes to match common configurations.  
Concave Profiles Used to sand convex surfaces. Available in several sizes  
to match common configurations.  
Angled Profiles Used to sand the bottom and sides of slots or grooves.  
Available in several angles to match common config-  
urations.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SELECTING THE ABRASIVE  
The best finishes can be achieved by selecting the proper type of abrasive.  
coarser grit abrasives will remove the most material while finer grit abrasives  
will produce the best finishes.  
Achieve best results by selecting the proper size and type of abrasives.  
Start the work with an abrasive grit just coarse enough to remove high spots  
and excessive roughness. Follow with a second sanding using a grit one or  
two grades finer. Continue using successively finer grits until the desired  
finish is obtained.  
ATTACHING PAD OR PROFILE MOUNTING PLATE  
All of the accessory pads and profile mounting plates are attached to the tool  
in the same way. Each pad or mounting plate has two posts (A) Fig. 7 used  
to attach it to the Profile Sander.  
One pad post fits into a pocket (B) Fig. 7 in the tool, and the other post is  
locked into place by a tab (C) Fig. 7. The mounting post area (of all the pads  
and mounting plates) is symmetrical. The pad (or mounting plate) can be  
attached to the Profile Sander with either end forward, which allows the use  
of both pointed ends of each sheet of pad abrasive, and permits the profile  
holders to be mounted in the best position for each particular application.  
To attach a pad or mounting plate to the Profile Sander:  
C
B
A
A
Fig. 7  
1.  
DISCONNECT TOOL FROM POWER SOURCE.  
2. Position one of the pad (or mounting plate) posts (A) Fig. 7 into the  
pocket (B) Fig. 7 of the Profile Sander (Fig. 8).  
3. Depress latch button (D) Fig. 9, seat pad to sander, and release latch  
button to secure the pad in place (Fig. 10).  
4. To remove pad (or mounting plate), depress latch button (D) Fig. 9, and  
pull pad away from sander.  
D
Fig. 8  
Fig. 9  
Fig. 10  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ATTACHING PROFILE TO MOUNTING PLATE  
Individual profiles may be mounted to either the Single Profile Mounting Plate,  
or the Angled Profile Mounting Plate (Figs. 11 and 12). The individual profiles  
are pressed into the slot on the mounting plate by hand, and can be removed  
from the mounting plate by pulling outward on one end of the profile.  
Fig. 12  
Fig. 11  
ATTACHING ABRASIVES  
Three different types of abrasives that can be used with the Profile Sander  
are:  
HOOK & LOOP SHEETS: These are precut sheets with hook & loop backing  
and dust extraction holes. This abrasive is used with the diamond shaped  
Hook & Loop Pad. Align the abrasive with the sander pad and press into place  
with the palm of your hand. Use a light twisting motion to lock the hooks into  
the loops. To remove abrasive, lift one corner with your fingernail and peel it  
off. These abrasives may be removed and reattached several times.  
PSA SHEETS: These are precut sheets with pressure sensitive adhesive.  
Precut diamond shaped sheets are available to fit the optional diamond  
shaped PSA Pad. Precut rectangular sheets are available to fit all of the  
individual profiles. Peel the protective sheet from the back of the abrasive.  
Align the abrasive with the sander pad and press firmly into place. To remove  
abrasive, lift one corner with your fingernail and peel it off. Discard the used  
abrasive.  
PSA ROLLS: These are 21/2" wide rolls with pressure sensitive adhesive. This  
abrasive is used with the individual profiles and with the extended “shutter”  
pad. Unroll a strip of abrasive to fit the particular profile (or pad), and cut to  
length with scissors. NOTE: For best results, the abrasive should cover all of  
the exposed profile below the profile holder. Firmly press the abrasive in  
place on the profile (or pad). To remove abrasive, lift one corner with your  
fingernail and peel it off. Discard the used abrasive.  
NOTE: PSA Pads and Profiles must be clean for the abrasives to adhere  
properly. Clean the pads and profiles with soap and water.  
PSA Adhesives work best at temperatures above 25° F. If PSA abrasives,  
pads, or profiles are stored at lower temperatures, warm them before use.  
Store PSA Pads in a dust-free environment to prevent contamination of the  
adhesive.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ATTACHING OPTIONAL DUST WAND  
NOTE: A wide variety of accessories, including a dust wand, is available for  
this tool. Please refer to your Porter-Cable Catalog to determine if the dust  
wand is supplied as standard equipment with your particular tool package.  
The dust wand is available as an accessory, and may be used with any  
Porter-Cable Model 444 Profile Sander.  
The dust wand requires an external vacuum source (shop vac or dust  
collection system). To attach dust wand to sander:  
1. Insert dust wand pin (A) Fig. 13 into hole (B) Fig. 13.  
2. Thread knob (C) Fig. 14 into tool, and tighten firmly.  
3. Connect the dust wand to your vacuum source with a 1" vacuum hose.  
C
A
B
Fig. 13  
Fig. 14  
TO START AND STOP SANDER  
The tool is equipped with a “rocker” type switch (A) Fig. 15 labeled “ON” and  
“OFF”.  
1. Depress “OFF”. Check to see that the power circuit voltage is the same  
as that shown on the specification plate.  
2. Connect Sander to power circuit.  
3. While holding Sander firmly, and off the work surface, depress “ON”.  
4. When you are finished sanding, lift the tool off the work and depress  
“OFF” to stop the tool.  
SPEED CONTROL (444VS only)  
Model 444VS is equipped with a variable speed control. Operating speed is  
adjustable between 2100 SPM (Strokes Per Minute) and 6000 SPM.  
Speed is adjustable by turning thumbwheel (B) Fig. 15A. Thumbwheel  
position #1 provides the slowest operating speed (2100 SPM) and position  
#6 the fastest (6000 SPM). Speed may be changed while motor is running or  
while stopped.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
B
A
Fig. 15  
Fig. 15A  
USING THE SANDER  
The Porter-Cable Profile Sander has been designed for one-hand operation  
(Fig. 16). The sander can be easily guided over the work surface with one  
hand. The normal weight of the machine is sufficient for efficient sanding.  
Additional pressure on the tool will slow down the speed of the pad, reduce  
the sanding efficiency, and put an additional burden on the motor.  
The Profile Sander uses an “in-line” sanding motion. To achieve the best  
surface finish, sand “in-line” with the wood grain. Faster removal rates can  
be achieved by operating the sander across the grain while working out  
rough areas, and then finishing by sanding with the grain.  
Fig. 16  
FINE FINISHING  
The action of the tool causes thousands of tiny abrasive grits to move  
against the work at high speed. Each grain moves in the same direction and  
at a constant speed, causing the cutting action to be uniform over the entire  
pad surface. Start the work with an abrasive grit just coarse enough to  
remove the high spots and excessive roughness.  
Follow with a second sanding using a grit one or two grades finer. Continue  
with successively finer grits until the desired finish is obtained. DO NOT GO  
FROM A COARSE GRIT TO A VERY FINE GRIT IN ONE STEP.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
REMOVING PAINT AND VARNISH  
Read and follow all instructions in the  
“ADDITIONAL SAFETY RULES FOR PAINT REMOVAL”  
section of this manual.  
To remove old paint and varnish:  
1. Use a coarse, open coat abrasive to avoid the usual clogging of the  
abrasive surfaces.  
2. Keep the machine moving over new areas to avoid heating and  
softening the material being removed.  
Try to work the entire surface at the same time by working in wide, over-  
lapping arcs. Do not concentrate on small areas. When using liquid  
removers or heaters to speed the work, scrape away all excess paint or  
varnish with a putty knife or other suitable scraping tool, and allow the wood  
to be cool and dry before sanding.  
DOORS AND MOLDINGS  
The “in-line” motion of the Profile Sander is ideally suited for use in the  
recessed corners and on the intricate profiles found on moldings and raised-  
panel doors. The diamond shaped pads make sanding the recessed corners  
easy, while the wide variety of available sanding profiles allow you to exactly  
match each detail of intricate molding configurations.  
TROUBLESHOOTING  
For assistance with your tool, visit our website at www.porter-cable.com for a  
list of service centers or call the Porter-Cable help line at 1-800-487-8665.  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MAINTENANCE  
KEEP TOOL CLEAN  
Periodically blow out all air passages with dry compressed air. All plastic parts  
should be cleaned with a soft damp cloth. NEVER use solvents to clean plastic  
parts. They could possibly dissolve or otherwise damage the material.  
Wear ANSI Z87.1 safety glasses while using compressed air.  
FAILURE TO START  
Should your tool fail to start, check to make sure the prongs on the cord plug are  
making good contact in the outlet. Also, check for blown fuses or open circuit  
breakers in the line.  
LUBRICATION  
This tool has been lubricated with a sufficient amount of high grade lubricant for  
the life of the unit under normal operating conditions. No further lubrication is  
necessary.  
BRUSH INSPECTION (If applicable)  
For your continued safety and electrical protection, brush inspection and  
replacement on this tool should ONLY be performed by an AUTHORIZED  
PORTER-CABLE SERVICE STATION or a PORTER-CABLEDELTA FACTORY  
SERVICE CENTER.  
At approximately 100 hours of use, take or send your tool to your nearest  
authorized Porter-Cable Service Station to be thoroughly cleaned and inspected.  
Have worn parts replaced and lubricated with fresh lubricant. Have new brushes  
installed, and test the tool for performance.  
Any loss of power before the above maintenance check may indicate the need  
for immediate servicing of your tool. DO NOT CONTINUE TO OPERATE TOOL  
UNDER THIS CONDITION. If proper operating voltage is present, return your  
tool to the service station for immediate service.  
SERVICE  
REPLACEMENT PARTS  
When servicing use only identical replacement parts. For a service parts list or to  
learn more about Porter-Cable visit our website at www.porter-cable.com  
SERVICE AND REPAIRS  
All quality tools will eventually require servicing, or replacement of parts due to  
wear from normal use. For assistance with your tool, visit our website at  
www.porter-cable.com for a list of service centers or call the Customer Care  
Department at 1-800-487-8665. All repairs made by our service centers are fully  
guaranteed against defective material and workmanship. We cannot guarantee  
repairs made or attempted by others.  
Should you have any questions about your tool, feel free to write us at any time.  
In any communications, please give all information shown on the nameplate of  
your tool (model number, type, serial number, etc.).  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACCESSORIES  
A complete line of accessories is available from your Porter-CableDelta  
Supplier, Porter-CableDelta Factory Service Centers, and Porter-Cable  
Authorized Service Stations. Please visit our Web Site www.porter-cable.com  
for a catalog or for the name of your nearest supplier.  
Since accessories other than those offered by  
Porter-CableDelta have not been tested with this product, use of  
such accessories could be hazardous. For safest operation, only  
Porter-CableDelta recommended accessories should be used  
with this product.  
WARRANTY  
PORTER-CABLE LIMITED  
ONE YEAR WARRANTY  
Porter-Cable warrants its Professional Power Tools for a period of one year from the date of original  
purchase. We will repair or replace at our option, any part or parts of the product and accessories  
covered under this warranty which, after examination, proves to be defective in workmanship or  
material during the warranty period. For repair or replacement return the complete tool or accessory,  
transportation prepaid, to your nearest Porter-Cable Service Center or Authorized Service Station.  
Proof of purchase may be required. This warranty does not apply to repair or replacement required  
due to misuse, abuse, normal wear and tear or repairs attempted or made by other than our Service  
Centers or Authorized Service Stations.  
ANY IMPLIED WARRANTY, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND  
FITNESS FOR A PARTICULAR PURPOSE, WILL LAST ONLY FOR ONE (1) YEAR FROM THE DATE  
OF PURCHASE.  
To obtain information on warranty performance please write to: PORTER-CABLE CORPORATION,  
4825 Highway 45 North, Jackson, Tennessee 38305; Attention: Product Service. THE FOREGOING  
OBLIGATION IS PORTER-CABLE’S SOLE LIABILITY UNDER THIS OR ANY IMPLIED WARRANTY  
AND UNDER NO CIRCUMSTANCES SHALL PORTER-CABLE BE LIABLE FOR ANY INCIDENTAL  
OR CONSEQUENTIAL DAMAGES. Some states do not allow limitations on how long an implied  
warranty lasts or the exclusion or limitation of incidental or consequential damages, so the above  
limitation or exclusion may not apply to you.  
This warranty gives you specific legal rights and you may also have other legal rights which vary  
from state to state.  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PORTER-CABLE • DELTA SERVICE CENTERS  
(CENTROS DE SERVICIO DE PORTER-CABLE • DELTA)  
(CENTRE DE SERVICE PORTER-CABLE • DELTA)  
Parts and Repair Service for Porter-Cable  
(Obtenga Refaccion de Partes o Servicio para su Herramienta en los Siguientes Centros de Porter-Cable  
(Locations où vous trouverez les pièces de rechange nécessaires ainsi qu’un service d’entretien)  
Delta Power Tools are Available at These Locations  
Delta)  
Cleveland 44125  
8001 Sweet Valley Drive  
Unit #19  
Phone: (216) 447-9030  
Fax: (216) 447-3097  
ARIZONA  
MINNESOTA  
Minneapolis 55429  
5522 Lakeland Avenue North  
Phone: (763) 561-9080  
Fax: (763) 561-0653  
GEORGIA  
Tempe 85282 (Phoenix)  
2400 West Southern Avenue  
Suite 105  
Phone: (602) 437-1200  
Fax: (602) 437-2200  
Forest Park 30297 (Atlanta)  
5442 Frontage Road,  
Suite 112  
Phone: (404) 608-0006  
Fax: (404) 608-1123  
OREGON  
MISSOURI  
Portland 97230  
CALIFORNIA  
North Kansas City 64116  
1141 Swift Avenue  
Phone: (816) 221-2070  
Fax: (816) 221-2897  
ILLINOIS  
4916 NE 122 nd Ave.  
Phone: (503) 252-0107  
Fax: (503) 252-2123  
Ontario 91761 (Los Angeles)  
3949A East Guasti Road  
Phone: (909) 390-5555  
Fax: (909) 390-5554  
Addison 60101 (Chicago)  
400 South Rohlwing Rd.  
Phone: (630) 424-8805  
Fax: (630) 424-8895  
PENNSYLVANIA  
St. Louis 63119  
Willow Grove 19090 (Philadelphia)  
520 North York Road  
Phone: (215) 658-1430  
Fax: (215) 658-1433  
7574 Watson Road  
Phone: (314) 968-8950  
Fax: (314) 968-2790  
Woodridge 60517 (Chicago)  
2033 West 75th Street  
Phone: (630) 910-9200  
Fax: (630) 910-0360  
San Diego 92111  
7638 Clairemont Blvd.  
Phone: (858) 277-9595  
Fax: (858) 277-9696  
NEW YORK  
TEXAS  
Flushing 11365-1595 (N.Y.C.)  
175-25 Horace Harding Expwy.  
Phone: (718) 225-2040  
Fax: (718) 423-9619  
MARYLAND  
San Leandro 94577 (Oakland)  
3039 Teagarden Street  
Phone: (510) 357-9762  
Fax: (510) 357-7939  
Carrollton 75006 (Dallas)  
1300 Interstate 35 N, Suite 112  
Phone: (972) 446-2996  
Fax: (972) 446-8157  
Elkridge 21075 (Baltimore)  
7397-102 Washington Blvd.  
Phone: (410) 799-9394  
Fax: (410) 799-9398  
NORTH CAROLINA  
Charlotte 28270  
9129 Monroe Road, Suite 115  
Phone: (704) 841-1176  
Fax: (704) 708-4625  
COLORADO  
Houston 77043  
4321 Sam Houston Parkway, West  
Suite 180  
Phone: (713) 983-9910  
Fax: (713) 983-6645  
MASSACHUSETTS  
Arvada 80003 (Denver)  
8175 Sheridan Blvd., Unit S  
Phone: (303) 487-1809  
Fax: (303) 487-1868  
Franklin 02038 (Boston)  
Franklin Industrial Park  
101E Constitution Blvd.  
Phone: (508) 520-8802  
Fax: (508) 528-8089  
OHIO  
FLORIDA  
WASHINGTON  
Columbus 43214  
4560 Indianola Avenue  
Phone: (614) 263-0929  
Fax: (614) 263-1238  
Davie 33314 (Miami)  
4343 South State Rd. 7 (441)  
Unit #107  
Phone: (954) 321-6635  
Fax: (954) 321-6638  
Auburn 98001(Seattle)  
3320 West Valley HWY, North  
Building D, Suite 111  
Phone: (253) 333-8353  
Fax: (253) 333-9613  
MICHIGAN  
Madison Heights 48071 (Detroit)  
30475 Stephenson Highway  
Phone: (248) 597-5000  
Fax: (248) 597-5004  
Tampa 33609  
4538 W. Kennedy Boulevard  
Phone: (813) 877-9585  
Fax: (813) 289-7948  
Authorized Service Stations are located in many large cities. Telephone 800-487-8665 or 731-541-6042 for assistance locating one. Parts and  
accessories for Porter-Cable Delta products should be obtained by contacting any Porter-Cable Delta Distributor, Authorized Service  
Center, or Porter-Cable Delta Factory Service Center. If you do not have access to any of these, call 888-848-5175 and you will be directed to  
the nearest Porter-Cable Delta Factory Service Center. Las Estaciones de Servicio Autorizadas están ubicadas en muchas grandes ciudades.  
Llame al 800-487-8665 ó al 731-541-6042 para obtener asistencia a fin de localizar una. Las piezas y los accesorios para los productos Porter-  
Cable Delta deben obtenerse poniéndose en contacto con cualquier distribuidor Porter-Cable Delta, Centro de Servicio Autorizado o Centro  
de Servicio de Fábrica Porter-Cable Delta. Si no tiene acceso a ninguna de estas opciones, llame al 888-848-5175 y le dirigirán al Centro de  
Servicio de Fábrica Porter-Cable Delta más cercano. Des centres de service agréés sont situés dans beaucoup de grandes villes. Appelez au  
800-487-8665 ou au 731-541-6042 pour obtenir de l’aide pour en repérer un. Pour obtenir des pièces et accessoires pour les produits Porter-  
Cable  
Delta, s’adresser à tout distributeur Porter-Cable  
Delta, centre de service agréé ou centre de service d’usine Porter-Cable  
Delta. Si  
vous n’avez accès à aucun de ces centres, appeler le 888-848-5175 et on vous dirigera vers le centre de service d’usine Porter-Cable  
Delta le  
plus proche.  
CANADIAN PORTER-CABLE DELTA SERVICE CENTERS  
QUÉBEC  
ALBERTA  
MANITOBA  
1515 Ave.  
Bay 6, 2520-23rd St. N.E.  
Calgary, Alberta  
T2E 8L2  
1699 Dublin Avenue  
Winnipeg, Manitoba  
R3H 0H2  
St-Jean Baptiste, Suite 160  
Québec, P.Q.  
G2E 5E2  
Phone: (418) 877-7112  
Fax: (418) 877-7123  
Phone: (403) 735-6166  
Fax: (403) 735-6144  
Phone: (204) 633-9259  
Fax: (204) 632-1976  
BRITISH COLUMBIA  
8520 Baxter Place  
Burnaby, B.C.  
V5A 4T8  
Phone: (604) 420-0102  
Fax: (604) 420-3522  
ONTARIO  
1447, Begin  
St-Laurent, (Mtl), P.Q.  
H4R 1V8  
Phone: (514) 336-8772  
Fax: (514) 336-3505  
505 Southgate Drive  
Guelph, Ontario  
N1H 6M7  
Phone: (519) 767-4132  
Fax: (519) 767-4131  
The following are trademarks of PORTER-CABLE  
DELTA (Las siguientes son marcas registradas de PORTER-CABLE  
DELTA S.A.) (Les  
marques suivantes sont des marques de fabriquant de la PORTER-CABLE  
DELTA): Auto-Set®, BAMMER®, B.O.S.S.®, Builder’s Saw®,  
Contractor’s Saw®, Contractor’s Saw II™, Delta®, DELTACRAFT®, DELTAGRAM™, Delta Series 2000™, DURATRONIC™, Emc²™, FLEX®, Flying  
Chips™, FRAME SAW®, Grip Vac™, Homecraft®, INNOVATION THAT WORKS®, Jet-Lock®, JETSTREAM®, ‘kickstand®, LASERLOC®, MICRO-  
SET®, Micro-Set®, MIDI LATHE®, MORTEN™, NETWORK™, OMNIJIG®, POCKET CUTTER®, PORTA-BAND®, PORTA-PLANE®, PORTER-  
CABLE®&(design), PORTER-CABLE®PROFESSIONAL POWER TOOLS, PORTER-CABLE REDEFINING PERFORMANCE™, Posi-Matic®, Q-  
3®&(design), QUICKSAND®&(design), QUICKSET™, QUICKSET II®, QUICKSET PLUS™, RIPTIDE™&(design), SAFE GUARD II®, SAFE-LOC®,  
Sanding Center®, SANDTRAP®&(design), SAW BOSS®, Sawbuck™, Sidekick®, SPEED-BLOC®, SPEEDMATIC®, SPEEDTRONIC®, STAIR EASE®,  
The American Woodshop®&(design), The Lumber Company®&(design), THE PROFESSIONAL EDGE®, THE PROFESSIONAL SELECT®, THIN-  
LINE™, TIGER®, TIGER CUB®, TIGER SAW®, TORQBUSTER®, TORQ-BUSTER®, TRU-MATCH™, TWIN-LITE®, UNIGUARD®, Unifence®,  
UNIFEEDER™, Unihead®, Uniplane™, Unirip®, Unisaw®, Univise®, Versa-Feeder®, VERSA-PLANE® , WHISPER SERIES®,  
WOODWORKER’S CHOICE™.  
Trademarks noted with ™ and ® are registered in the United States Patent and Trademark Office and may also be registered in other countries.  
Las Marcas Registradas con el signo de ™ y ® son registradas por la Oficina de Registros y Patentes de los Estados Unidos y también pueden  
estar registradas en otros países. Marques déposées, indiquées par la lettre ™ et ®, sont déposées au Bureau des brevets d’invention et  
marques déposéesDauoxwEtnatlso-aUndisfertopmourWraiewnwt ê.tSreodémpoasnéeusaalusx.cauotrmes.pAaylsl.Manuals Search And Download  
.
PC7.2-0105-164  

Pelco Satellite Radio FR8301 User Manual
Perlick Ice Maker ANSI NSF User Manual
Perlick Refrigerator BSDZ User Manual
Philips CD Player AZ7000 User Manual
Philips Cell Phone CT6598 User Manual
Philips Music Mixer SA615 User Manual
PoGo Products MP3 Player Radio YourWay User Manual
Polaroid Flat Panel Television FXM 2611C User Manual
Pride Mobility Mobility Aid Jazzy 600 2S User Manual
PYLE Audio MP3 Docking Station PIWPD3 User Manual