PROBLEM
POSSIBLE CAUSE
SOLUTION
Position the FUEL VALVE
Turn the ignition key to
DANGER
7.
8.
Engine will not start.
- Engine switch is off.
- No fuel.
- Turn engine switch to ON.
- Fill fuel tank.
to ON.
START position. When the
engine starts, release the
key.
Using a generator indoors CAN KILL YOU IN MINUTES.
Generator exhaust contains carbon monoxide.
This is a poison you cannot see or smell.
Do not connect to a building’s
electrical system unless the generator
and transfer switch have been verified
by a qualified electrician. The
- Stale fuel or water
in fuel.
- Drain entire fuel system
and refill with fresh fuel.
OFF
ON
- Engine oil level is low.
- Engine is equipped with
Low Oil Shutoff. If the
engine oil level is
low, the unit will not start.
Check engine oil
connection must isolate the generator
power from utility power and must
comply with all applicable laws and
electrical codes.
- Spark plug faulty, fouled
or improperly gapped.
NEVER use inside a home
or garage. EVEN IF doors
and windows are open.
Only use OUTSIDE and
far away from windows,
doors, and vents.
- Choke lever is in
RUN position.
level and fill if necessary.
- Engine stored without
treating or draining
fuel.
FUEL VALVE
START
- Replace spark plug.
First Time Starting
Add engine lubricant per the Operator’s Manual instructions.
- Move choke lever to
START position.
Once the engine is running,
slowly push the choke knob
in to the RUN position.
After a 2-3 minute warm up,
Position the SMART
THROTTLE switch to ON.
- Refueled with bad
fuel.
9.
10.
- Drain fuel and carburetor.
Refuel with fresh
fuel.
1.
- Dirty fuel filter.
- Contact authorized
service dealer.
CHOKE
Engine hard to start.
Engine lacks power.
- Water in fuel.
- Drain entire system and
refill with fresh fuel.
- Weak spark at spark plug.
- Contact authorized
service dealer.
Oil fill recommendations using included oil fill bottle:
P3000iE
- Dirty air filter.
- Check air filter element.
3 oil fill bottles up to #2 mark
- Engine stored without
treating or draining
fuel, or refueled with
bad fuel.
- Clean or replace as
needed.
Stopping The Unit
Always verify oil level is at upper limit mark on dipstick before operating.
- Drain fuel and carburetor.
- Refuel with fresh fuel.
Disconnect all appliances
Allow the engine to cool.
Turn the FUEL VALVE
to OFF.
1.
2.
connected to the generator.
Position the Ignition Switch
to OFF.
Connect Battery Cables to
positive (+) and negative (-)
terminals.
Install and tighten battery
3.
holder over battery.
2.
AC receptacle does not work.
DC receptacle does not work.
Item plugged in is defective.
Overload indicator on (light
solid)
- Try a different item.
- Press reset button.
Slide boots over cables
and terminals.
OFF
ON
- Circuit protector engaged.
- Item plugged in is defective.
- Remove any load from
the generator.
- Replace the fuse,
then depress the DC
circuit breaker.
FUEL VALVE
- Try a different item.
START
Generator makes a “spark
knock” or “pinging” noise.
- If knocking or pinging
occurs under normal load
at a steady engine
speed, the problem may
be with the fuel
- Switch to a different
brand of fuel with
a octane rating of 86 or
higher.
USING THE GENERATOR
Connect devices to be powered by following the steps below.
- Make sure the total rated power from the items you plan to use at the
same time are less than the generator continuous (running) watts. Make
sure the total surge (starting) power from the items you plan to use at the
same time are less than the generator maximum watts. See Operator’s
Manual to calculate total amount of power needed.
Fill the fuel tank per the Operator’s Manual instructions.
- Contact authorized
service dealer.
4.
5.
being used.
NOTICE:
Do not use E15 or E85 fuel
(or fuel containing greater than 10% ethanol) in this
product. It is violation of federal law and will damage
the unit and void your warranty.
- An occasional light
“knocking” or “pinging”
under heavy load is not a
cause for concern.
- Start the generator with nothing connected.
If problems persist after trying the above solutions, contact your authorized service dealer.
- Plug in and turn on the first load (perferably the largest load).
- Allow the generator output to stabilize (engine runs smoothly and
attached device operates properly).
The following symptoms may indicate problems that will affect the emissions level on the unit.
- Hard starting or stalling
- Rough idle
Position the SMART
THROTTLE switch to
OFF.
Pull CHOKE knob out to
choke engine.
6.
- Repeat previous steps for additional loads.
- Misfiring or backfiring under load
IMPORTANT: Never add more load than the generator’s capacity. Please
consider surge load when determining total power need.
- Afterburning (backfiring)
- Black exhaust smoke or high fuel consumption
If you encounter any of these symptoms, take the unit to your authorized service dealer for service.
CHOKE
STORING THE UNIT
When preparing to store the generator, allow the unit to cool completely. If the
unit is going to be stored for more than 4 weeks, turn off generator by turning
fuel valve to the OFF position. After the generator stops running, turn key to
the OFF position. Follow complete storage instructions in Operator’s Manual.
9926058 R1
Download from Www.Somanuals.com. All Manuals Search And Download.
|