Plinius Audio Car Amplifier Anniversary Integrated Amplifier User Manual |
ANNIVERSARY
INTEGRATED AMPLIFIER
INSTRUCTION MANUAL
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
Congratulations on your decision to become the proud owner of this
Plinius Anniversary Integrated Amplifier.
This manual has been prepared to help you understand the operation of your amplifier,
and to provide information about its design and the variety of ways it may be used.
We have designed and manufactured this amplifier to reproduce your favourite music
faithfully and accurately. With a little care and a full understanding of the operating
recommendations in this manual, your Plinius Anniversary Integrated Amplifier will
provide years of high-quality, trouble-free performance.
Please take the time to read this manual thoroughly before using your amplifier.
SERIAL NUMBER
FINAL TEST CERTIFIED BY
2
PLINIUS ANNIVERSARY
Download from Www.Somanuals.com. All Manuals Search And Download.
Design Philosophy
The design of the Anniversary set draws on the aesthetic values of strength and
simplicity of the past 30 years and continues our company’s focus on meeting the
high standards required to always be at ‘The Heart of Music’.
The unique design of the Anniversary set incorporates the current design language of
Plinius, with the push buttons on the front panel operating the control system on the
integrated amplifier, while maintaining our history in the anodised brushed finishes. The
unique subtle blue-silver colouring portraying a titanium strength and the black ultra
matt chassis highlighted by Plinius Blue markings, creates a fusion of future and history.
The strong full aluminium wrap of the outer skin and cover creates a clean crisp
statement of strength, and the simplicity of the control and display layout maintains
the interface that is now synonymous to Plinius. The Integrated Amplifier and CD
player both now carry a new foot which allows for some height adjustment and to
improve resonance qualities.
Additional changes to the layout of internal components and changes to the rear
panel along with fine tuning of aesthetic detailing, further illustrate our 30 years of
striving to create ‘The Heart of Music’.
Michael Denton
DESIGN DIRECTOR
INTEGRATED AMPLIFIER
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Unpacking
Open the box from the top and remove the accessories from the foam end caps.
You may now proceed to lift the unit from the box, Once the unit is removed you can
proceed with the removal of the foam end caps. These caps are designed to fit on
the front and back of the unit for maximum protection. Retain the packaging for future
transportation of this unit.
Placement & Ventilation
Your Anniversary Integrated Amplifier may operate at a moderately high temperature,
especially during extended listening sessions. The ideal location is upon a rigid
stand, away from direct contact with any temperature sensitive materials, furniture or
deep pile carpets. Ventilation through and around the amplifier should also be kept
unimpeded. Please ensure that the heat vents (slots in the base and lid) are not
covered or restricted in any way.
The Anniversary Integrated Amplifier design incorporates a very high level of
mechanical decoupling of the input and output. It can however still be influenced by
acoustical feedback in the operating environment. The use of acoustic cones or a
suitably spiked amplifier stand or table may further enhance the performance of this
preamplifier. Consult your Plinius dealer for further advice if required.
4
PLINIUS ANNIVERSARY
Download from Www.Somanuals.com. All Manuals Search And Download.
Care & Maintenance
With simple care and maintenance your Plinius product can be kept looking and
operating like new for many years to come.
MAINTAINING THE CONNECTORS
Exposed connectors such as the RCA connectors will be subject to environmental
factors, and over time the surface may degrade. This can be greatly reduced by fitting
readily available ‘RCA caps’ to reduce the effects of environmental elements on the RCA
connectors. These RCA caps or RCA shorting caps can also provide sonic benefits.
Connector cleaning products are also available to clean the RCA and cable connectors
and frequent checks and cleaning will help maintain a good signal connection.
NOTE: DO NOT use RCA shorting caps on output connectors or power amplifier input
connectors. Use RCA shorting caps on unused preamplifier stage input connectors only.
Standard RCA shielding caps can be used on any unused input or output connectors.
MAINTAINING THE SWITCHES
Switches should be maintained by using each various switch setting periodically.
Even if a switch or a switch setting is not used, it is a good idea to toggle small
switches and turn rotary switches though the full range of the switch several times in
succession to keep the contacts active. Performing this simple action will promote
longevity of the switch contacts.
SURFACE CLEANING
From time to time you may wish to clean the surface of your Plinius equipment to
remove dust, or any material build up from the atmosphere or on commonly used
controls. Your Plinius product is made up of parts that have a hard anodised or a
powder coat finish and will clean easily without being damaged.
Cleaning should be carried out using a soft cleaning cloth, dry or with either a small
amount of water or a very mild surface cleaner, while observing the following guidelines:
ꢀ As a safety precaution, always switch the equipment off prior to cleaning
ꢀ Always use a cloth that is soft and clean
ꢀ Never use abrasives or polishing compounds anywhere on the unit
ꢀ Never apply liquid directly to the surface of the unit
ꢀ Use the cloth dry or with mild surface cleaners of either liquid or foaming type
ꢀ Apply only small amounts of cleaner to the cloth
ꢀ DO NOT rub the surface but wipe clean only. Excessive rubbing may dull powder
coat or wear the screen printed text.
INTEGRATED AMPLIFIER
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Precautions
PLEASE TAKE SPECIAL NOTE OF THE FOLLOWING PRECAUTIONS
BEFORE OPERATING YOUR NEW AMPLIFIER.
ꢀ The Plinius Anniversary Integrated Amplifier can deliver in excess of 200 watts into
8 ohms. This amplifier is also capable of a very large peak current delivery.
ꢀ The Plinius Anniversary Integrated Amplifier operates in Class AB. It is capable of
generating heat that could have an adverse effect on other electronic equipment,
furniture, etc.
ꢀ DO NOT leave flammable material on the amplifier whilst running, as this could
pose a serious fire risk.
ꢀ This amplifier operates at hazardous voltage levels. There are some alterations
that may be made by you, the owner. However, we recommend that any work
requiring removal of the lid be referred to a suitably qualified and experienced
service technician.
ꢀ DO NOT attempt to connect any input of this amplifier to its own outputs.
ꢀ DO NOT earth any output terminal or connect any of these terminals together
without following the instructions in this manual or seeking qualified assistance.
ꢀ DO NOT place this amplifier in any position where liquids, or any foreign material
may accidentally enter it.
ꢀ DO NOT connect any voltage source, short circuit, earth/ground or appliance
(other than suitable high fidelity loudspeakers) to the amplifier output terminals.
6
PLINIUS ANNIVERSARY
Download from Www.Somanuals.com. All Manuals Search And Download.
Front Panel Functions
The front of the Plinius Anniversary Integrated Amplifier incorporates all the facilities
you will require on a daily basis.
5
1
2
3
4
1. DISPLAY LED
The blue LED on the front panel indicates the mode of operation. When first switched
on the unit will go into standby and the display LED will vary in brightness. When the unit
is taken out of standby and is ready for use, the LED will remain lit. Whenever mute or a
remote volume button is pressed, the LED will dim.
2. SOURCE SELECTION BUTTONS
The buttons on the front panel allow selection of any of the different inputs available
on the rear panel. This selection is fed to the Pre Out, Line Out and speaker outputs of
the amplifier.
3. SOURCE DISPLAY LEDS
These small white LEDs communicate the current source selection.
4. HT BYPASS LED
This small white LED is ON when the current source selection is the HT Bypass Input.
This input can be selected using the remote control or activated by the trigger input.
5. VOLUME CONTROL KNOB
The volume control is a motorised unit that will accurately convey the selected source
signal to the line stage of the Plinius Anniversary Integrated Amplifier. When using
the remote control to alter the volume level, briefly press the button to make small
adjustments, or hold the button down to continuously adjust the volume.
INTEGRATED AMPLIFIER
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Rear Panel Functions
This panel incorporates all terminals for connecting the input signals from your CD player,
tuner, etc and the outputs to the loudspeakers and mains supply. Please remember
that your Plinius Anniversary Integrated Amplifier is a high quality electronic instrument
capable of an exceptional level of performance. Be sure that you understand your
system’s requirements fully before you make any connection to this amplifier.
5
6
7
1
8
8
2
2
9
4
10
13
11
3
12
1. MAINS SWITCH
The heavy-duty rocker switch in the centre of the panel turns the Mains/Line Power to
the amplifier ON or OFF. The amplifier draws a moderately high current when switched
on, so it is not good practice to rapidly turn the Mains switch on and off repeatedly.
2. INPUT TERMINALS
The input terminals for your Plinius Anniversary Integrated Amplifier are easily
accessible along the top of the rear panel, with the right channel (red) inputs along
the top. The phono inputs are suitable only for low level input phono turntables, while
the rest are all ‘line level’ inputs, for use with unbalanced signals from line level source
components such as CD players, tuners, etc. Consult your Plinius dealer for further
advice if required.
3. CD XLR INPUT TERMINALS
Below the Line Out and Trigger Connectors are an additional set of ‘line level’ XLR
balanced inputs for use with source components that feature XLR balanced outputs.
Balanced signals are carried via a three way cable.
The XLR pin configuration used in all Plinius product is:
PIN 1 to GND
PIN 2 to +Signal
PIN 3 to -Signal
NOTE: Because of the way our XLR and balanced inputs are configured it is not
possible to use both XLR and RCA at the same time.
8
PLINIUS ANNIVERSARY
Download from Www.Somanuals.com. All Manuals Search And Download.
4. INPUT SELECTION SWITCH
This switch directly above the ‘CD XLR’ input is used to select the pair of CD input
sockets required as described above. Towards the RIGHT channel selects the CD
RCA input connections, while towards the LEFT channel selects CD XLR input.
5. HT BYPASS INPUT
This input is for use specifically with home theatre processors. In some circumstances
you may wish to use the power amplifier of the Anniversary Integrated as the front two
channels of a surround or home theatre environment. The HT Bypass input can be
used for this purpose, as any signal connected to these inputs can be sent directly to
the power amplifier bypassing the preamplifier entirely. It is accessed by the remote
or the trigger input.
6. PRE OUT
The Pre Out connection is provided to enable the Anniversary Integrated Amplifier to
be connected to an external power amplifier.
7. LINE OUT
These RCA outputs are situated next to Pre Out and are provided to interface to line
level recording devices for archiving, or transferring to portable media. The outputs
are always live with the signal of whichever source is selected at the time of recording.
8. OUTPUT TERMINALS
Connections for the loudspeakers are provided on either side of the rear panel. Two
parallel pairs of five way binding posts for each channel are fitted – these provide
ease of use with bi-wiring and multiple cables requiring a large contact area.
9. REMOTE TRIGGER INPUT/OUTPUT SOCKETS
In order to integrate more effectively into a home theatre system, the Anniversary
Integrated has a remote trigger input socket fitted to the rear panel. By connecting
a processor with a remote trigger signal to this socket, the Anniversary Integrated
can be switched between HT Bypass and standby modes. When in standby the
amplifier draws less current and will operate at minimum temperature. This may be
of advantage in multi-amplifier and/or remote installations. The Anniversary Integrated
also features a remote trigger output socket fitted to the rear panel. By connecting
this trigger output to other system components, the entire system can be put in and
out of standby by the processor.
10. GROUND LIFT SWITCH
This switch allows the signal ground to be disconnected from the chassis. In some
installations a hum loop may exist due to duplicate ground paths from different
equipment. Use this switch to remove the connection from 0V to ground thus
allowing some flexibility in your particular set-up.
INTEGRATED AMPLIFIER
9
Download from Www.Somanuals.com. All Manuals Search And Download.
11. MAINS POWER CORD IEC SOCKET
This connector is where the mains supply cable from your wall connects to the
amplifier. You will notice that a fuse holder is mounted within this connection, and it
holds a mains fuse to provide surge and overload protection for your amplifier.
12. RAIL FUSES
These tubular fuse holders house the positive and negative rail protection fuses.
Depress and turn anti-clockwise to open. An LED is fitted next to each fuse holder
and will illuminate to indicate a blown fuse.
13. PHONO EARTH POST
This is a chassis connected gold-plated earth post for use with most vinyl turntables.
10
PLINIUS ANNIVERSARY
Download from Www.Somanuals.com. All Manuals Search And Download.
Remote Control Functions
The Plinius Anniversary Integrated Amplifier features a full function remote to control all
settings and configurations of the amplifier as well as complete controls for operating
the Anniversary CD player.
INTEGRATED AMPLIFIER REMOTE FUNCTIONS:
1. STANDBY
Standby is used to put the unit into a low power mode. This
1
3
2
4
disconnects the outputs of the Integrated Amplifier and turns off
the white display LED’s. It also switches the integrated amplifier to
a low bias mode to reduce power consumption and still keep the
circuitry active. This allows a minimum warm up period before the
Plinius Anniversary Integrated Amplifier is at it’s sonic best.
5
2. DISPLAY
6
8
The display button on the remote enables you to adjust the
display brightness of the white LED’s. Pressing the display button
repeatedly will dim the LED in steps until they are off. The next
press of the button will cycle the display back to full brightness.
7
9
10
11
3. SOURCE SELECTION
The source selection buttons enable changing from one input to
another when needed and can be scrolled left or right to select the
desired source. On reaching the left most or right most input, the
selection will scroll in a continuos loop with the next button press.
12
4. HT BYPASS
The HT Bypass button activates the Plinius Anniversary Integrated
Amplifier home theatre bypass mode. Once activated, the
preamplifier is bypassed and the signal is transmitted from the HT
Bypass input directly to the power amplifier. NOTE: In HT Bypass
mode the only buttons that continue to function are Standby
and Display. More information on HT Bypass can be found in the
Installation & Operation section in this manual.
5. VOLUME CONTROL
Use these two buttons to control the volume level of the Integrated Amplifier. The
right side button increases volume, while the left side button decreases the volume.
Briefly press either button to make fine adjustments to the volume level. Hold down
either button to continually adjust the volume level.
INTEGRATED AMPLIFIER
11
Download from Www.Somanuals.com. All Manuals Search And Download.
6. MUTE
Pressing this button toggles the Anniversary Integrated Amplifier in and out of mute.
CD PLAYER REMOTE FUNCTIONS:
7. REPEAT
The repeat LED on the front panel will illuminate once this button is pressed. The
Anniversary CD Player will now play all tracks on the CD as normal, but then repeat
all tracks from track 1 in an endless loop. It does not repeat one track only, but will
repeat the entire contents on the CD.
8. DISPLAY
This function enables you to quickly adjust the display brightness. Use this button
to toggle between high, low, and off settings. Note that whenever the compact disc
drawer is ejected to change a CD, the display will automatically revert to full brightness.
9. CUE BUTTONS
Use these two buttons to cue through the track you are listening to. Press and hold
the right side button to cue forward through the track, or press and hold the left side
button to cue backwards through the track. Once the start or end of the track is
reached, Cue will continue into the next track.
10. TRACK BUTTONS
The track buttons enable you to move forward (right button) or back (left button)
through the tracks on the CD. Press the button once to skip to the next track on the
CD, or hold down to skip through multiple tracks. When you press the back button
once the Anniversary CD Player will revert to the start of the current track. Pressing
the back button again will skip back to the previous track. The track currently selected
will be brightly lit.
11. STOP/EJECT
If the Anniversary CD player is playing a CD, pressing the Stop/Eject button will stop
play and return to track 1. Pressing the button again will open the compact disc
drawer so the CD can be changed.
12. PLAY/PAUSE
Press the Play/Pause button to begin playing the CD at the track selected. The
display LED corresponding to the track that is being played will vary in brightness.
Press the Play button again, and the track will pause, designated by the LED flashing.
If the compact disc drawer is open, pressing play will shut the drawer and start
playing the CD from track 1.
12
PLINIUS ANNIVERSARY
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation & Operation
WARNING: RISK OF ELECTRIC SHOCK
This amplifier operates at hazardous voltage levels. We recommend that any work
requiring removal of the lid be referred to a suitably qualified and experienced service
technician. DO NOT place this amplifier in any position where liquids or any foreign
material may accidentally enter it.
PLEASE READ & UNDERSTAND THE PRECAUTIONS WITHIN THIS MANUAL
FOR PLACEMENT & OPERATION OF THIS PRODUCT.
CONNECTIONS
Connections to your Anniversary Integrated Amplifier should be made in the same
order as they are listed in this section. DO NOT attempt to connect your Anniversary
Integrated Amplifier until you have read and fully understood these instructions.
Should you require further assistance, please contact your Plinius dealer.
DO NOT POWER UP YOUR AMPLIFIER UNTIL YOU HAVE CONNECTED
YOUR INPUT/OUTPUTS CORRECTLY FOR YOUR SYSTEM.
SOURCE COMPONENT INPUTS
Connect your Source to the input of the Anniversary Integrated Amplifier using
suitable single-ended RCA or Balanced XLR interconnect cables only. For RCA, make
sure you connect the red coded cable to the red RIGHT RCA input, and the white
cable to the white LEFT RCA input. Also make sure the RCA connectors are a snug fit
and are inserted all the way in.
For CD XLR input connection, make sure you connect the RIGHT XLR input and LEFT
XLR inputs to the right and left outputs from your source respectively. Also make sure
the XLR connectors click into place. Use the input selection switch to select RCA if
you are using RCA inputs or to select XLR if you are using XLR inputs.
NOTE: DO NOT connect XLR and RCA at the same time, use only one or the other. The
phono input should be connected to a suitable source turntable only.
ANNIVERSARY CD PLAYER
INTEGRATED AMPLIFIER
CD INPUTS
INTEGRATED AMPLIFIER
13
Download from Www.Somanuals.com. All Manuals Search And Download.
LOUDSPEAKER OUTPUTS
The connection of your loudspeakers to the output posts of the Anniversary
Integrated Amplifier must be made by an ‘instructed person’ with suitable ready
made loudspeaker cables only. Connect your left loudspeaker (ie. the one on your
left when seated in your normal listening position) to the left output terminals.
Ensure the terminals on the amplifier are connected to the loudspeaker terminals
Red positive (+) to Red positive (+) and Black negative (–) to Black negative (–).
Repeat this process for the right outputs.
RIGHT SPEAKER
+ RIGHT –
OUTPUTS
– LEFT +
LEFT SPEAKER
TERMINATION QUALITY
Quality of the connections must be examined to ensure that high-performance,
trouble-free operation is enjoyed. Check that the connections are tight but do not
over tighten. If bare wires are used make sure that no loose strands of wire short
across the other terminals or the amplifier chassis. When using plugs such as
bananas, be sure to use good quality plugs with a firm fit.
BI-WIRING
Bi-wiring uses two pairs of loudspeaker cables for each channel loudspeaker. You
will notice that the rear panel of your Anniversary Integrated Amplifier has two pairs
of output terminals for this purpose. When bi-wiring, always connect the terminals
positive (+) to positive (+) and negative (–) to negative (–). Be sure to remove any
jumpers that may be fitted to your loudspeakers.
PHASING (OR POLARITY)
It is important to achieve good stereo imaging in your listening room. By observing
the wiring instructions above, each power amplifier/loudspeaker combination should
be in phase. If you experience poor stereo image and/or a lack of bass, check that
the loudspeaker wiring has been connected correctly. If in doubt, consult your Plinius
dealer for advice.
Naturally it is also important to make sure all the leads carrying signals for the RIGHT channel
loudspeaker are connected to the RIGHT input to the amplifier from your preamplifier or
CD player etc. Signals for the LEFT channel should be wired in a similar fashion.
14
PLINIUS ANNIVERSARY
Download from Www.Somanuals.com. All Manuals Search And Download.
USING HT BYPASS INPUT
The Anniversary Integrated Amplifier features a home theatre input to bypass the
preamplifier stage when used in home theatre or multimedia installations. When
HT Bypass is selected, the signal will pass from the HT Bypass input directly to the
Anniversary Integrated power amplifiers.
This enables the unit to remain in circuit for use with two channel sources (such as
CD players and tuners), as well as a link to the speakers should you wish to use your
normal stereo set-up in a surround or home theatre environment.
To access the HT Bypass input, press the HT button on the remote control. To exit the
HT Bypass mode and return to using a source component, press HT again, or use the
source buttons to scroll to any desired source component.
NOTE: Only connect a suitable pre out signal to the HT Bypass input. When HT Bypass
is selected, remote volume cannot be accessed.
USING PRE OUT
A line level output is provided on the back of the Anniversary Integrated Amplifier. If
you wish to use the Anniversary Integrated Amplifier as a pre-amp only, or to send
signal to another amplifier, fit the interconnect cable to the Pre Out outputs. The signal
from this output is preamplifier out level, and as such is not amplified by the power
stage of the Anniversary Integrated Amplifier. The output level remains adjustable
by using the volume control. Note that the Pre Out connections provide signal from
whatever the source selector knob is currently set to.
CONNECTING THE MAINS SUPPLY
Firstly, check that the mains supply voltage printed on the rear of this amplifier is
similar to the mains supply voltage in your area. If in doubt, please consult your
Plinius dealer. Mains supply power connection is via the plug-in lead supplied with
your Anniversary Integrated Amplifier. Where possible, check the wall outlet is
switched OFF, then connect the local mains plug end of the lead to the wall outlet.
Check the Integrated Amplifier is switched OFF, and connect the IEC end of the cable
to the IEC socket at the back of the integrated amplifier. With the cord fully connected,
switch the wall outlet ON.
Now that your Anniversary Integrated Amplifier is configured correctly, switch the
power switch on the rear panel to ON. The display LED will cycle in brightness for
approximately ten seconds as the internal circuitry stabilises. You can now enjoy your
new Plinius Anniversary Integrated Amplifier.
NOTE: This unit must be connected to a mains socket outlet with a protective earthing
connection. The wall outlet socket or mains switch must be accessible at all times in
case of emergency.
INTEGRATED AMPLIFIER
15
Download from Www.Somanuals.com. All Manuals Search And Download.
WARM-UP PERIOD
You will find that the Anniversary Integrated Amplifier will become noticeably ‘purer’
in sound after being on for a period of time. We usually recommend waiting at least
24 hours before expecting the best quality of sound reproduction from your amplifier.
Also, as the Anniversary Integrated Amplifier uses very little power while on, we
suggest leaving the unit turned on so that it will always be at its sonic best.
16
PLINIUS ANNIVERSARY
Download from Www.Somanuals.com. All Manuals Search And Download.
Product Features
REMOTE CONTROL
Provided with your Anniversary Integrated Amplifier is a 16 function remote control.
Two AAA batteries power the remote, and these are replaced by removing the two
screws on the base of the remote that hold the battery compartment in place. The
bottom end of the remote is now free to slide out for access to the batteries. Replace
the two batteries, taking care to refit the new ones with correct polarity.
PHONO GAIN ADJUSTMENT
The phono stage can also be set to high or low gain to suit your phono turntable
specifications (high gain is the factory setting). Disconnect the lead from the IEC
socket on your Anniversary Integrated Amplifier and make sure the Mains switch is
OFF. Carefully remove the lid by undoing the cap screws on the top. Locate the
small black phono jumpers to the middle-right side of the top circuit board. The gain
can now be adjusted noting that high gain (factory setting) is set with jumpers to the
left, and low gain is set with jumpers to the right. Now re-assemble your Anniversary
Integrated Amplifier.
FUSE PROTECTION
When any rail fuse is damaged one or more fuse warning LED’s will light. These LED’s
are located next to the fuse that has blown. To replace the fuse, disconnect the
amplifier from the mains power and wait 30 minutes, then firmly push in the round fuse
cap with your fingers. When the cap cannot push in any further, rotate the cap anti-
clockwise (to the left) until it comes to a stop. Release inward pressure on the fuse cap
and it can now be removed from the amplifier. Replace them with the same type only.
To re-fit the fuse, insert the fuse and gently turn it as far as possible anti-clockwise (to
the left). Now push the fuse cap in firmly, then turn clockwise (to the right) until it comes
to a stop. Release inward pressure on the cap and the fuse will be fitted securely.
IMPORTANT: DO NOT FIT A FUSE WITH A HIGHER RATING.
NOTE: that fuse failure may indicate a severe problem. Check all speakers and
speaker cables for damage etc. Should the amplifier continue to exhibit rail fuse
failure, contact your Plinius dealer.
MAINS/LINE FUSE
A Mains/Line fuse is fitted within the IEC socket on the rear of the amplifier. A small
drawer at the bottom of this socket may be removed (after the IEC plug is removed)
by levering it out with a flat blade screwdriver. The fuse fitted should be rated as
specified on the rear panel.
INTEGRATED AMPLIFIER
17
Download from Www.Somanuals.com. All Manuals Search And Download.
IMPORTANT: DO NOT FIT A FUSE WITH A HIGHER RATING.
In the unusual event that this fuse should blow, you must first establish the cause of
this failure (such as power surges, damaged mains cable, etc) before replacing the
fuse with one of the same rating and type. Should the amplifier continue to suffer
mains fuse failure, contact your Plinius dealer.
OVER TEMPERATURE PROTECTION
The Anniversary Integrated Amplifier is fitted with an auto-reset thermal sensor. The
sensor is located at the main power transformer and should the transformer internal
temperature exceed 110°C (230°F) the power will be disconnected from the unit.
The unit will remain off until the temperate has reduced significantly, and then the
sensor will automatically reset to the ON state.
If Over Temperature Protection occurs you should switch the unit off immediately. Check
the placement of the unit and ensure there is adequate airflow above and around the
unit. Refer to the Placement & Ventilation section on page 4 for further information.
18
PLINIUS ANNIVERSARY
Download from Www.Somanuals.com. All Manuals Search And Download.
Loudspeaker Selection
Your Plinius Anniversary Integrated Amplifier is designed for use with high fidelity
loudspeakers. It should not be used to operate with any other type of appliance or
equipment.
Be certain that your loudspeakers can handle most of the rated output power of this
amplifier. You may find loudspeaker specifications confusing or misleading, so you
should discuss this with your audio dealer prior to purchase. As a general rule, the
use of high power (200 Watt RMS or greater) loudspeakers is recommended and
desirable. However, our experience indicates that medium to low power loudspeakers
(100 to 200 Watt RMS) are quite often suitable for use on this amplifier, provided the
volume is maintained at a level where no distortion is audible.
Impedance of the loudspeaker load is important to ensure the rated performance
of this amplifier. If you have doubts about the impedance of your loudspeaker
configuration, we recommend you speak to your Plinius dealer.
INTEGRATED AMPLIFIER
19
Download from Www.Somanuals.com. All Manuals Search And Download.
Troubleshooting
NO SOUND FROM THE UNIT
If the unit is not reproducing audio take the following steps:
ꢀ Check the source is correctly connected to an appropriate input on the unit.
Refer to the Installation & Operation section on page 13.
ꢀ Check the source is playing, and not paused or muted. If it has adjustable
volume, check this is at the usual output level.
ꢀ Check the unit is set to select the correct source input. Adjust the ‘Source’
selector for the correct source component.
ꢀ Check the volume. Turn the unit volume up to a point just below the normal
listening level. DO NOT turn the volume up to maximum in case the sound begins
to come through the speakers.
ꢀ Check the unit is not in Mute. If the Display LED is dim, this indicates the unit is in
Mute mode. The Display LED should be full brightness for operational mode.
ꢀ Check the processor switch setting. This must be set to ‘Bypass’ (towards the
Speaker outputs) when using source components connected to the unit. Set
Processor Bypass to ‘ON’ for listening to sources via the processor or home
theatre equipment.
SOUND IS QUIET OR DISTORTED
If the sound is quiet or distorted a rail fuse may have failed. While the unit is ON
check the fuses in the rear panel. A Red LED being on will indicate a fuse failure. If the
fuse has failed, see Fuse Protection in the Product Features section of this manual.
NOTE: If the unit immediately or repeatedly suffers rail fuse failure, there may be a
major problem and you should contact your Plinius dealer.
POWER FAILURE
The unit may have suffered mains fuse failure or be in thermal overload protection mode.
ꢀ Mains Fuse Failure: Check the mains fuse and replace if needed.
ꢀ Thermal Overload Protection: Assess the temperature of the unit. If the unit seems
excessively hot, the Over Temperature Protection may have activated.
Refer to the Product Features section on page 17 for further information.
NOTE: If the unit immediately or repeatedly suffers mains fuse failure or thermal overload
protection, there may be a major problem and you should contact your Plinius dealer.
20
PLINIUS ANNIVERSARY
Download from Www.Somanuals.com. All Manuals Search And Download.
Specifications
POWER
200 watts RMS per channel into 8 ohms.
280 watts RMS per channel into 4 ohms.
Both channels driven from 20Hz to 20kHz at
less than 0.2% total harmonic distortion
FREQUENCY RESPONSE
20Hz to 20kHz +/–0.2dB
–3dB at 5Hz and –3dB at 70kHz
DISTORTION
Typically <0.05% THD at rated power
0.2% THD and IM worst case prior to clipping
CURRENT OUTPUT
40A short duration peak per channel
Fuse protected
SLEWING
50V/µs
HUM & NOISE
90dB below rated output 20Hz to 20kHz
unweighted
GAIN
Line inputs to speaker out: 40dB
Phono Input to Pre Out: 66dB on high gain,
60dB on low gain
INPUT IMPEDANCE
47k ohms all inputs
INPUT OVERLOAD
5V RMS
RATED PRE OUT LEVEL
1.5V RMS into 47k ohms or higher
PRE OUT SOURCE IMPEDANCE
Typically 1.5k ohms
PRE OUT MINIMUM RECOMMENDED LOAD
47k ohms
LINE OUT LEVEL
190mV at 200 ohms
Tape loop muting at 5V RMS input
POWER/CURRENT CONSUMPTION
600VA
0.4A (92W) Class AB Idle
DIMENSIONS
Height: 120mm (4.75")
Width: 450mm (17.75")
Depth: 400mm (15.75")
Weight: 14kg
(30lbs)
INTEGRATED AMPLIFIER
21
Download from Www.Somanuals.com. All Manuals Search And Download.
Index
Bi-wiring.........................................................................................................14
Display LED.................................................................................................7
Front Panel Layout...............................................................................7
Fuse Protection.......................................................................................17
Ground Lift Switch................................................................................9
HT Bypass....................................................................................................9, 15
IEC Power Connector........................................................................10, 15
Input Terminals........................................................................................8, 13
Line Out.........................................................................................................9
Loudspeaker Impedance ..............................................................19
Loudspeaker Power............................................................................19
Mains/Line Fuse.....................................................................................17
Mains Supply Connection .............................................................15
Mains Switch .............................................................................................8
Operating Temperature....................................................................4, 18
Output Terminals ...................................................................................9, 14
Over Temperature Protection......................................................18
Phasing..........................................................................................................14
Phono Earth Post ..................................................................................10
Phono Gain Adjustment ..................................................................17
Phono Inputs.............................................................................................8, 13
Placement ...................................................................................................4
Pre Out Output ........................................................................................9, 15
Rail Fuses ....................................................................................................10, 17
Rear Panel Layout.................................................................................8
Remote Control.......................................................................................11, 17
Safety Precautions ...............................................................................6
Serial Number..........................................................................................2
Source Selection Buttons..............................................................7
Terminations..............................................................................................14
Troubleshooting......................................................................................20
Ventilation.....................................................................................................4, 13
Volume Control........................................................................................7
Warm-Up Period.....................................................................................16
22
PLINIUS ANNIVERSARY
Download from Www.Somanuals.com. All Manuals Search And Download.
|