Plinius Audio Car Amplifier Anniversary Integrated Amplifier User Manual

ANNIVERSARY  
INTEGRATED AMPLIFIER  
INSTRUCTION MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Introduction  
Congratulations on your decision to become the proud owner of this  
Plinius Anniversary Integrated Amplifier.  
This manual has been prepared to help you understand the operation of your amplifier,  
and to provide information about its design and the variety of ways it may be used.  
We have designed and manufactured this amplifier to reproduce your favourite music  
faithfully and accurately. With a little care and a full understanding of the operating  
recommendations in this manual, your Plinius Anniversary Integrated Amplifier will  
provide years of high-quality, trouble-free performance.  
Please take the time to read this manual thoroughly before using your amplifier.  
SERIAL NUMBER  
FINAL TEST CERTIFIED BY  
2
PLINIUS ANNIVERSARY  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design Philosophy  
The design of the Anniversary set draws on the aesthetic values of strength and  
simplicity of the past 30 years and continues our company’s focus on meeting the  
high standards required to always be at ‘The Heart of Music’.  
The unique design of the Anniversary set incorporates the current design language of  
Plinius, with the push buttons on the front panel operating the control system on the  
integrated amplifier, while maintaining our history in the anodised brushed finishes. The  
unique subtle blue-silver colouring portraying a titanium strength and the black ultra  
matt chassis highlighted by Plinius Blue markings, creates a fusion of future and history.  
The strong full aluminium wrap of the outer skin and cover creates a clean crisp  
statement of strength, and the simplicity of the control and display layout maintains  
the interface that is now synonymous to Plinius. The Integrated Amplifier and CD  
player both now carry a new foot which allows for some height adjustment and to  
improve resonance qualities.  
Additional changes to the layout of internal components and changes to the rear  
panel along with fine tuning of aesthetic detailing, further illustrate our 30 years of  
striving to create ‘The Heart of Music’.  
Michael Denton  
DESIGN DIRECTOR  
INTEGRATED AMPLIFIER  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Unpacking  
Open the box from the top and remove the accessories from the foam end caps.  
You may now proceed to lift the unit from the box, Once the unit is removed you can  
proceed with the removal of the foam end caps. These caps are designed to fit on  
the front and back of the unit for maximum protection. Retain the packaging for future  
transportation of this unit.  
Placement & Ventilation  
Your Anniversary Integrated Amplifier may operate at a moderately high temperature,  
especially during extended listening sessions. The ideal location is upon a rigid  
stand, away from direct contact with any temperature sensitive materials, furniture or  
deep pile carpets. Ventilation through and around the amplifier should also be kept  
unimpeded. Please ensure that the heat vents (slots in the base and lid) are not  
covered or restricted in any way.  
The Anniversary Integrated Amplifier design incorporates a very high level of  
mechanical decoupling of the input and output. It can however still be influenced by  
acoustical feedback in the operating environment. The use of acoustic cones or a  
suitably spiked amplifier stand or table may further enhance the performance of this  
preamplifier. Consult your Plinius dealer for further advice if required.  
4
PLINIUS ANNIVERSARY  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Care & Maintenance  
With simple care and maintenance your Plinius product can be kept looking and  
operating like new for many years to come.  
MAINTAINING THE CONNECTORS  
Exposed connectors such as the RCA connectors will be subject to environmental  
factors, and over time the surface may degrade. This can be greatly reduced by fitting  
readily available ‘RCA caps’ to reduce the effects of environmental elements on the RCA  
connectors. These RCA caps or RCA shorting caps can also provide sonic benefits.  
Connector cleaning products are also available to clean the RCA and cable connectors  
and frequent checks and cleaning will help maintain a good signal connection.  
NOTE: DO NOT use RCA shorting caps on output connectors or power amplifier input  
connectors. Use RCA shorting caps on unused preamplifier stage input connectors only.  
Standard RCA shielding caps can be used on any unused input or output connectors.  
MAINTAINING THE SWITCHES  
Switches should be maintained by using each various switch setting periodically.  
Even if a switch or a switch setting is not used, it is a good idea to toggle small  
switches and turn rotary switches though the full range of the switch several times in  
succession to keep the contacts active. Performing this simple action will promote  
longevity of the switch contacts.  
SURFACE CLEANING  
From time to time you may wish to clean the surface of your Plinius equipment to  
remove dust, or any material build up from the atmosphere or on commonly used  
controls. Your Plinius product is made up of parts that have a hard anodised or a  
powder coat finish and will clean easily without being damaged.  
Cleaning should be carried out using a soft cleaning cloth, dry or with either a small  
amount of water or a very mild surface cleaner, while observing the following guidelines:  
˜ꢀ As a safety precaution, always switch the equipment off prior to cleaning  
˜ꢀ Always use a cloth that is soft and clean  
˜ꢀ Never use abrasives or polishing compounds anywhere on the unit  
˜ꢀ Never apply liquid directly to the surface of the unit  
˜ꢀ Use the cloth dry or with mild surface cleaners of either liquid or foaming type  
˜ꢀ Apply only small amounts of cleaner to the cloth  
˜ꢀ DO NOT rub the surface but wipe clean only. Excessive rubbing may dull powder  
coat or wear the screen printed text.  
INTEGRATED AMPLIFIER  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Precautions  
PLEASE TAKE SPECIAL NOTE OF THE FOLLOWING PRECAUTIONS  
BEFORE OPERATING YOUR NEW AMPLIFIER.  
˜ꢀ The Plinius Anniversary Integrated Amplifier can deliver in excess of 200 watts into  
8 ohms. This amplifier is also capable of a very large peak current delivery.  
˜ꢀ The Plinius Anniversary Integrated Amplifier operates in Class AB. It is capable of  
generating heat that could have an adverse effect on other electronic equipment,  
furniture, etc.  
˜ꢀ DO NOT leave flammable material on the amplifier whilst running, as this could  
pose a serious fire risk.  
˜ꢀ This amplifier operates at hazardous voltage levels. There are some alterations  
that may be made by you, the owner. However, we recommend that any work  
requiring removal of the lid be referred to a suitably qualified and experienced  
service technician.  
˜ꢀ DO NOT attempt to connect any input of this amplifier to its own outputs.  
˜ꢀ DO NOT earth any output terminal or connect any of these terminals together  
without following the instructions in this manual or seeking qualified assistance.  
˜ꢀ DO NOT place this amplifier in any position where liquids, or any foreign material  
may accidentally enter it.  
˜ꢀ DO NOT connect any voltage source, short circuit, earth/ground or appliance  
(other than suitable high fidelity loudspeakers) to the amplifier output terminals.  
6
PLINIUS ANNIVERSARY  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Front Panel Functions  
The front of the Plinius Anniversary Integrated Amplifier incorporates all the facilities  
you will require on a daily basis.  
5
1
2
3
4
1. DISPLAY LED  
The blue LED on the front panel indicates the mode of operation. When first switched  
on the unit will go into standby and the display LED will vary in brightness. When the unit  
is taken out of standby and is ready for use, the LED will remain lit. Whenever mute or a  
remote volume button is pressed, the LED will dim.  
2. SOURCE SELECTION BUTTONS  
The buttons on the front panel allow selection of any of the different inputs available  
on the rear panel. This selection is fed to the Pre Out, Line Out and speaker outputs of  
the amplifier.  
3. SOURCE DISPLAY LEDS  
These small white LEDs communicate the current source selection.  
4. HT BYPASS LED  
This small white LED is ON when the current source selection is the HT Bypass Input.  
This input can be selected using the remote control or activated by the trigger input.  
5. VOLUME CONTROL KNOB  
The volume control is a motorised unit that will accurately convey the selected source  
signal to the line stage of the Plinius Anniversary Integrated Amplifier. When using  
the remote control to alter the volume level, briefly press the button to make small  
adjustments, or hold the button down to continuously adjust the volume.  
INTEGRATED AMPLIFIER  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Rear Panel Functions  
This panel incorporates all terminals for connecting the input signals from your CD player,  
tuner, etc and the outputs to the loudspeakers and mains supply. Please remember  
that your Plinius Anniversary Integrated Amplifier is a high quality electronic instrument  
capable of an exceptional level of performance. Be sure that you understand your  
system’s requirements fully before you make any connection to this amplifier.  
5
6
7
1
8
8
2
2
9
4
10  
13  
11  
3
12  
1. MAINS SWITCH  
The heavy-duty rocker switch in the centre of the panel turns the Mains/Line Power to  
the amplifier ON or OFF. The amplifier draws a moderately high current when switched  
on, so it is not good practice to rapidly turn the Mains switch on and off repeatedly.  
2. INPUT TERMINALS  
The input terminals for your Plinius Anniversary Integrated Amplifier are easily  
accessible along the top of the rear panel, with the right channel (red) inputs along  
the top. The phono inputs are suitable only for low level input phono turntables, while  
the rest are all ‘line level’ inputs, for use with unbalanced signals from line level source  
components such as CD players, tuners, etc. Consult your Plinius dealer for further  
advice if required.  
3. CD XLR INPUT TERMINALS  
Below the Line Out and Trigger Connectors are an additional set of ‘line level’ XLR  
balanced inputs for use with source components that feature XLR balanced outputs.  
Balanced signals are carried via a three way cable.  
The XLR pin configuration used in all Plinius product is:  
PIN 1 to GND  
PIN 2 to +Signal  
PIN 3 to -Signal  
NOTE: Because of the way our XLR and balanced inputs are configured it is not  
possible to use both XLR and RCA at the same time.  
8
PLINIUS ANNIVERSARY  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. INPUT SELECTION SWITCH  
This switch directly above the ‘CD XLR’ input is used to select the pair of CD input  
sockets required as described above. Towards the RIGHT channel selects the CD  
RCA input connections, while towards the LEFT channel selects CD XLR input.  
5. HT BYPASS INPUT  
This input is for use specifically with home theatre processors. In some circumstances  
you may wish to use the power amplifier of the Anniversary Integrated as the front two  
channels of a surround or home theatre environment. The HT Bypass input can be  
used for this purpose, as any signal connected to these inputs can be sent directly to  
the power amplifier bypassing the preamplifier entirely. It is accessed by the remote  
or the trigger input.  
6. PRE OUT  
The Pre Out connection is provided to enable the Anniversary Integrated Amplifier to  
be connected to an external power amplifier.  
7. LINE OUT  
These RCA outputs are situated next to Pre Out and are provided to interface to line  
level recording devices for archiving, or transferring to portable media. The outputs  
are always live with the signal of whichever source is selected at the time of recording.  
8. OUTPUT TERMINALS  
Connections for the loudspeakers are provided on either side of the rear panel. Two  
parallel pairs of five way binding posts for each channel are fitted – these provide  
ease of use with bi-wiring and multiple cables requiring a large contact area.  
9. REMOTE TRIGGER INPUT/OUTPUT SOCKETS  
In order to integrate more effectively into a home theatre system, the Anniversary  
Integrated has a remote trigger input socket fitted to the rear panel. By connecting  
a processor with a remote trigger signal to this socket, the Anniversary Integrated  
can be switched between HT Bypass and standby modes. When in standby the  
amplifier draws less current and will operate at minimum temperature. This may be  
of advantage in multi-amplifier and/or remote installations. The Anniversary Integrated  
also features a remote trigger output socket fitted to the rear panel. By connecting  
this trigger output to other system components, the entire system can be put in and  
out of standby by the processor.  
10. GROUND LIFT SWITCH  
This switch allows the signal ground to be disconnected from the chassis. In some  
installations a hum loop may exist due to duplicate ground paths from different  
equipment. Use this switch to remove the connection from 0V to ground thus  
allowing some flexibility in your particular set-up.  
INTEGRATED AMPLIFIER  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
11. MAINS POWER CORD IEC SOCKET  
This connector is where the mains supply cable from your wall connects to the  
amplifier. You will notice that a fuse holder is mounted within this connection, and it  
holds a mains fuse to provide surge and overload protection for your amplifier.  
12. RAIL FUSES  
These tubular fuse holders house the positive and negative rail protection fuses.  
Depress and turn anti-clockwise to open. An LED is fitted next to each fuse holder  
and will illuminate to indicate a blown fuse.  
13. PHONO EARTH POST  
This is a chassis connected gold-plated earth post for use with most vinyl turntables.  
10  
PLINIUS ANNIVERSARY  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Remote Control Functions  
The Plinius Anniversary Integrated Amplifier features a full function remote to control all  
settings and configurations of the amplifier as well as complete controls for operating  
the Anniversary CD player.  
INTEGRATED AMPLIFIER REMOTE FUNCTIONS:  
1. STANDBY  
Standby is used to put the unit into a low power mode. This  
1
3
2
4
disconnects the outputs of the Integrated Amplifier and turns off  
the white display LED’s. It also switches the integrated amplifier to  
a low bias mode to reduce power consumption and still keep the  
circuitry active. This allows a minimum warm up period before the  
Plinius Anniversary Integrated Amplifier is at it’s sonic best.  
5
2. DISPLAY  
6
8
The display button on the remote enables you to adjust the  
display brightness of the white LED’s. Pressing the display button  
repeatedly will dim the LED in steps until they are off. The next  
press of the button will cycle the display back to full brightness.  
7
9
10  
11  
3. SOURCE SELECTION  
The source selection buttons enable changing from one input to  
another when needed and can be scrolled left or right to select the  
desired source. On reaching the left most or right most input, the  
selection will scroll in a continuos loop with the next button press.  
12  
4. HT BYPASS  
The HT Bypass button activates the Plinius Anniversary Integrated  
Amplifier home theatre bypass mode. Once activated, the  
preamplifier is bypassed and the signal is transmitted from the HT  
Bypass input directly to the power amplifier. NOTE: In HT Bypass  
mode the only buttons that continue to function are Standby  
and Display. More information on HT Bypass can be found in the  
Installation & Operation section in this manual.  
5. VOLUME CONTROL  
Use these two buttons to control the volume level of the Integrated Amplifier. The  
right side button increases volume, while the left side button decreases the volume.  
Briefly press either button to make fine adjustments to the volume level. Hold down  
either button to continually adjust the volume level.  
INTEGRATED AMPLIFIER  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6. MUTE  
Pressing this button toggles the Anniversary Integrated Amplifier in and out of mute.  
CD PLAYER REMOTE FUNCTIONS:  
7. REPEAT  
The repeat LED on the front panel will illuminate once this button is pressed. The  
Anniversary CD Player will now play all tracks on the CD as normal, but then repeat  
all tracks from track 1 in an endless loop. It does not repeat one track only, but will  
repeat the entire contents on the CD.  
8. DISPLAY  
This function enables you to quickly adjust the display brightness. Use this button  
to toggle between high, low, and off settings. Note that whenever the compact disc  
drawer is ejected to change a CD, the display will automatically revert to full brightness.  
9. CUE BUTTONS  
Use these two buttons to cue through the track you are listening to. Press and hold  
the right side button to cue forward through the track, or press and hold the left side  
button to cue backwards through the track. Once the start or end of the track is  
reached, Cue will continue into the next track.  
10. TRACK BUTTONS  
The track buttons enable you to move forward (right button) or back (left button)  
through the tracks on the CD. Press the button once to skip to the next track on the  
CD, or hold down to skip through multiple tracks. When you press the back button  
once the Anniversary CD Player will revert to the start of the current track. Pressing  
the back button again will skip back to the previous track. The track currently selected  
will be brightly lit.  
11. STOP/EJECT  
If the Anniversary CD player is playing a CD, pressing the Stop/Eject button will stop  
play and return to track 1. Pressing the button again will open the compact disc  
drawer so the CD can be changed.  
12. PLAY/PAUSE  
Press the Play/Pause button to begin playing the CD at the track selected. The  
display LED corresponding to the track that is being played will vary in brightness.  
Press the Play button again, and the track will pause, designated by the LED flashing.  
If the compact disc drawer is open, pressing play will shut the drawer and start  
playing the CD from track 1.  
12  
PLINIUS ANNIVERSARY  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation & Operation  
WARNING: RISK OF ELECTRIC SHOCK  
This amplifier operates at hazardous voltage levels. We recommend that any work  
requiring removal of the lid be referred to a suitably qualified and experienced service  
technician. DO NOT place this amplifier in any position where liquids or any foreign  
material may accidentally enter it.  
PLEASE READ & UNDERSTAND THE PRECAUTIONS WITHIN THIS MANUAL  
FOR PLACEMENT & OPERATION OF THIS PRODUCT.  
CONNECTIONS  
Connections to your Anniversary Integrated Amplifier should be made in the same  
order as they are listed in this section. DO NOT attempt to connect your Anniversary  
Integrated Amplifier until you have read and fully understood these instructions.  
Should you require further assistance, please contact your Plinius dealer.  
DO NOT POWER UP YOUR AMPLIFIER UNTIL YOU HAVE CONNECTED  
YOUR INPUT/OUTPUTS CORRECTLY FOR YOUR SYSTEM.  
SOURCE COMPONENT INPUTS  
Connect your Source to the input of the Anniversary Integrated Amplifier using  
suitable single-ended RCA or Balanced XLR interconnect cables only. For RCA, make  
sure you connect the red coded cable to the red RIGHT RCA input, and the white  
cable to the white LEFT RCA input. Also make sure the RCA connectors are a snug fit  
and are inserted all the way in.  
For CD XLR input connection, make sure you connect the RIGHT XLR input and LEFT  
XLR inputs to the right and left outputs from your source respectively. Also make sure  
the XLR connectors click into place. Use the input selection switch to select RCA if  
you are using RCA inputs or to select XLR if you are using XLR inputs.  
NOTE: DO NOT connect XLR and RCA at the same time, use only one or the other. The  
phono input should be connected to a suitable source turntable only.  
ANNIVERSARY CD PLAYER  
INTEGRATED AMPLIFIER  
CD INPUTS  
INTEGRATED AMPLIFIER  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
LOUDSPEAKER OUTPUTS  
The connection of your loudspeakers to the output posts of the Anniversary  
Integrated Amplifier must be made by an ‘instructed person’ with suitable ready  
made loudspeaker cables only. Connect your left loudspeaker (ie. the one on your  
left when seated in your normal listening position) to the left output terminals.  
Ensure the terminals on the amplifier are connected to the loudspeaker terminals  
Red positive (+) to Red positive (+) and Black negative (–) to Black negative (–).  
Repeat this process for the right outputs.  
RIGHT SPEAKER  
+ RIGHT –  
OUTPUTS  
– LEFT +  
LEFT SPEAKER  
TERMINATION QUALITY  
Quality of the connections must be examined to ensure that high-performance,  
trouble-free operation is enjoyed. Check that the connections are tight but do not  
over tighten. If bare wires are used make sure that no loose strands of wire short  
across the other terminals or the amplifier chassis. When using plugs such as  
bananas, be sure to use good quality plugs with a firm fit.  
BI-WIRING  
Bi-wiring uses two pairs of loudspeaker cables for each channel loudspeaker. You  
will notice that the rear panel of your Anniversary Integrated Amplifier has two pairs  
of output terminals for this purpose. When bi-wiring, always connect the terminals  
positive (+) to positive (+) and negative (–) to negative (–). Be sure to remove any  
jumpers that may be fitted to your loudspeakers.  
PHASING (OR POLARITY)  
It is important to achieve good stereo imaging in your listening room. By observing  
the wiring instructions above, each power amplifier/loudspeaker combination should  
be in phase. If you experience poor stereo image and/or a lack of bass, check that  
the loudspeaker wiring has been connected correctly. If in doubt, consult your Plinius  
dealer for advice.  
Naturally it is also important to make sure all the leads carrying signals for the RIGHT channel  
loudspeaker are connected to the RIGHT input to the amplifier from your preamplifier or  
CD player etc. Signals for the LEFT channel should be wired in a similar fashion.  
14  
PLINIUS ANNIVERSARY  
Download from Www.Somanuals.com. All Manuals Search And Download.  
USING HT BYPASS INPUT  
The Anniversary Integrated Amplifier features a home theatre input to bypass the  
preamplifier stage when used in home theatre or multimedia installations. When  
HT Bypass is selected, the signal will pass from the HT Bypass input directly to the  
Anniversary Integrated power amplifiers.  
This enables the unit to remain in circuit for use with two channel sources (such as  
CD players and tuners), as well as a link to the speakers should you wish to use your  
normal stereo set-up in a surround or home theatre environment.  
To access the HT Bypass input, press the HT button on the remote control. To exit the  
HT Bypass mode and return to using a source component, press HT again, or use the  
source buttons to scroll to any desired source component.  
NOTE: Only connect a suitable pre out signal to the HT Bypass input. When HT Bypass  
is selected, remote volume cannot be accessed.  
USING PRE OUT  
A line level output is provided on the back of the Anniversary Integrated Amplifier. If  
you wish to use the Anniversary Integrated Amplifier as a pre-amp only, or to send  
signal to another amplifier, fit the interconnect cable to the Pre Out outputs. The signal  
from this output is preamplifier out level, and as such is not amplified by the power  
stage of the Anniversary Integrated Amplifier. The output level remains adjustable  
by using the volume control. Note that the Pre Out connections provide signal from  
whatever the source selector knob is currently set to.  
CONNECTING THE MAINS SUPPLY  
Firstly, check that the mains supply voltage printed on the rear of this amplifier is  
similar to the mains supply voltage in your area. If in doubt, please consult your  
Plinius dealer. Mains supply power connection is via the plug-in lead supplied with  
your Anniversary Integrated Amplifier. Where possible, check the wall outlet is  
switched OFF, then connect the local mains plug end of the lead to the wall outlet.  
Check the Integrated Amplifier is switched OFF, and connect the IEC end of the cable  
to the IEC socket at the back of the integrated amplifier. With the cord fully connected,  
switch the wall outlet ON.  
Now that your Anniversary Integrated Amplifier is configured correctly, switch the  
power switch on the rear panel to ON. The display LED will cycle in brightness for  
approximately ten seconds as the internal circuitry stabilises. You can now enjoy your  
new Plinius Anniversary Integrated Amplifier.  
NOTE: This unit must be connected to a mains socket outlet with a protective earthing  
connection. The wall outlet socket or mains switch must be accessible at all times in  
case of emergency.  
INTEGRATED AMPLIFIER  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARM-UP PERIOD  
You will find that the Anniversary Integrated Amplifier will become noticeably ‘purer’  
in sound after being on for a period of time. We usually recommend waiting at least  
24 hours before expecting the best quality of sound reproduction from your amplifier.  
Also, as the Anniversary Integrated Amplifier uses very little power while on, we  
suggest leaving the unit turned on so that it will always be at its sonic best.  
16  
PLINIUS ANNIVERSARY  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Product Features  
REMOTE CONTROL  
Provided with your Anniversary Integrated Amplifier is a 16 function remote control.  
Two AAA batteries power the remote, and these are replaced by removing the two  
screws on the base of the remote that hold the battery compartment in place. The  
bottom end of the remote is now free to slide out for access to the batteries. Replace  
the two batteries, taking care to refit the new ones with correct polarity.  
PHONO GAIN ADJUSTMENT  
The phono stage can also be set to high or low gain to suit your phono turntable  
specifications (high gain is the factory setting). Disconnect the lead from the IEC  
socket on your Anniversary Integrated Amplifier and make sure the Mains switch is  
OFF. Carefully remove the lid by undoing the cap screws on the top. Locate the  
small black phono jumpers to the middle-right side of the top circuit board. The gain  
can now be adjusted noting that high gain (factory setting) is set with jumpers to the  
left, and low gain is set with jumpers to the right. Now re-assemble your Anniversary  
Integrated Amplifier.  
FUSE PROTECTION  
When any rail fuse is damaged one or more fuse warning LED’s will light. These LED’s  
are located next to the fuse that has blown. To replace the fuse, disconnect the  
amplifier from the mains power and wait 30 minutes, then firmly push in the round fuse  
cap with your fingers. When the cap cannot push in any further, rotate the cap anti-  
clockwise (to the left) until it comes to a stop. Release inward pressure on the fuse cap  
and it can now be removed from the amplifier. Replace them with the same type only.  
To re-fit the fuse, insert the fuse and gently turn it as far as possible anti-clockwise (to  
the left). Now push the fuse cap in firmly, then turn clockwise (to the right) until it comes  
to a stop. Release inward pressure on the cap and the fuse will be fitted securely.  
IMPORTANT: DO NOT FIT A FUSE WITH A HIGHER RATING.  
NOTE: that fuse failure may indicate a severe problem. Check all speakers and  
speaker cables for damage etc. Should the amplifier continue to exhibit rail fuse  
failure, contact your Plinius dealer.  
MAINS/LINE FUSE  
A Mains/Line fuse is fitted within the IEC socket on the rear of the amplifier. A small  
drawer at the bottom of this socket may be removed (after the IEC plug is removed)  
by levering it out with a flat blade screwdriver. The fuse fitted should be rated as  
specified on the rear panel.  
INTEGRATED AMPLIFIER  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IMPORTANT: DO NOT FIT A FUSE WITH A HIGHER RATING.  
In the unusual event that this fuse should blow, you must first establish the cause of  
this failure (such as power surges, damaged mains cable, etc) before replacing the  
fuse with one of the same rating and type. Should the amplifier continue to suffer  
mains fuse failure, contact your Plinius dealer.  
OVER TEMPERATURE PROTECTION  
The Anniversary Integrated Amplifier is fitted with an auto-reset thermal sensor. The  
sensor is located at the main power transformer and should the transformer internal  
temperature exceed 110°C (230°F) the power will be disconnected from the unit.  
The unit will remain off until the temperate has reduced significantly, and then the  
sensor will automatically reset to the ON state.  
If Over Temperature Protection occurs you should switch the unit off immediately. Check  
the placement of the unit and ensure there is adequate airflow above and around the  
unit. Refer to the Placement & Ventilation section on page 4 for further information.  
18  
PLINIUS ANNIVERSARY  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Loudspeaker Selection  
Your Plinius Anniversary Integrated Amplifier is designed for use with high fidelity  
loudspeakers. It should not be used to operate with any other type of appliance or  
equipment.  
Be certain that your loudspeakers can handle most of the rated output power of this  
amplifier. You may find loudspeaker specifications confusing or misleading, so you  
should discuss this with your audio dealer prior to purchase. As a general rule, the  
use of high power (200 Watt RMS or greater) loudspeakers is recommended and  
desirable. However, our experience indicates that medium to low power loudspeakers  
(100 to 200 Watt RMS) are quite often suitable for use on this amplifier, provided the  
volume is maintained at a level where no distortion is audible.  
Impedance of the loudspeaker load is important to ensure the rated performance  
of this amplifier. If you have doubts about the impedance of your loudspeaker  
configuration, we recommend you speak to your Plinius dealer.  
INTEGRATED AMPLIFIER  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Troubleshooting  
NO SOUND FROM THE UNIT  
If the unit is not reproducing audio take the following steps:  
˜ꢀ Check the source is correctly connected to an appropriate input on the unit.  
Refer to the Installation & Operation section on page 13.  
˜ꢀ Check the source is playing, and not paused or muted. If it has adjustable  
volume, check this is at the usual output level.  
˜ꢀ Check the unit is set to select the correct source input. Adjust the ‘Source’  
selector for the correct source component.  
˜ꢀ Check the volume. Turn the unit volume up to a point just below the normal  
listening level. DO NOT turn the volume up to maximum in case the sound begins  
to come through the speakers.  
˜ꢀ Check the unit is not in Mute. If the Display LED is dim, this indicates the unit is in  
Mute mode. The Display LED should be full brightness for operational mode.  
˜ꢀ Check the processor switch setting. This must be set to ‘Bypass’ (towards the  
Speaker outputs) when using source components connected to the unit. Set  
Processor Bypass to ‘ON’ for listening to sources via the processor or home  
theatre equipment.  
SOUND IS QUIET OR DISTORTED  
If the sound is quiet or distorted a rail fuse may have failed. While the unit is ON  
check the fuses in the rear panel. A Red LED being on will indicate a fuse failure. If the  
fuse has failed, see Fuse Protection in the Product Features section of this manual.  
NOTE: If the unit immediately or repeatedly suffers rail fuse failure, there may be a  
major problem and you should contact your Plinius dealer.  
POWER FAILURE  
The unit may have suffered mains fuse failure or be in thermal overload protection mode.  
˜ꢀ Mains Fuse Failure: Check the mains fuse and replace if needed.  
˜ꢀ Thermal Overload Protection: Assess the temperature of the unit. If the unit seems  
excessively hot, the Over Temperature Protection may have activated.  
Refer to the Product Features section on page 17 for further information.  
NOTE: If the unit immediately or repeatedly suffers mains fuse failure or thermal overload  
protection, there may be a major problem and you should contact your Plinius dealer.  
20  
PLINIUS ANNIVERSARY  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Specifications  
POWER  
200 watts RMS per channel into 8 ohms.  
280 watts RMS per channel into 4 ohms.  
Both channels driven from 20Hz to 20kHz at  
less than 0.2% total harmonic distortion  
FREQUENCY RESPONSE  
20Hz to 20kHz +/–0.2dB  
–3dB at 5Hz and –3dB at 70kHz  
DISTORTION  
Typically <0.05% THD at rated power  
0.2% THD and IM worst case prior to clipping  
CURRENT OUTPUT  
40A short duration peak per channel  
Fuse protected  
SLEWING  
50V/µs  
HUM & NOISE  
90dB below rated output 20Hz to 20kHz  
unweighted  
GAIN  
Line inputs to speaker out: 40dB  
Phono Input to Pre Out: 66dB on high gain,  
60dB on low gain  
INPUT IMPEDANCE  
47k ohms all inputs  
INPUT OVERLOAD  
5V RMS  
RATED PRE OUT LEVEL  
1.5V RMS into 47k ohms or higher  
PRE OUT SOURCE IMPEDANCE  
Typically 1.5k ohms  
PRE OUT MINIMUM RECOMMENDED LOAD  
47k ohms  
LINE OUT LEVEL  
190mV at 200 ohms  
Tape loop muting at 5V RMS input  
POWER/CURRENT CONSUMPTION  
600VA  
0.4A (92W) Class AB Idle  
DIMENSIONS  
Height: 120mm (4.75")  
Width: 450mm (17.75")  
Depth: 400mm (15.75")  
Weight: 14kg  
(30lbs)  
INTEGRATED AMPLIFIER  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Index  
Bi-wiring.........................................................................................................14  
Display LED.................................................................................................7  
Front Panel Layout...............................................................................7  
Fuse Protection.......................................................................................17  
Ground Lift Switch................................................................................9  
HT Bypass....................................................................................................9, 15  
IEC Power Connector........................................................................10, 15  
Input Terminals........................................................................................8, 13  
Line Out.........................................................................................................9  
Loudspeaker Impedance ..............................................................19  
Loudspeaker Power............................................................................19  
Mains/Line Fuse.....................................................................................17  
Mains Supply Connection .............................................................15  
Mains Switch .............................................................................................8  
Operating Temperature....................................................................4, 18  
Output Terminals ...................................................................................9, 14  
Over Temperature Protection......................................................18  
Phasing..........................................................................................................14  
Phono Earth Post ..................................................................................10  
Phono Gain Adjustment ..................................................................17  
Phono Inputs.............................................................................................8, 13  
Placement ...................................................................................................4  
Pre Out Output ........................................................................................9, 15  
Rail Fuses ....................................................................................................10, 17  
Rear Panel Layout.................................................................................8  
Remote Control.......................................................................................11, 17  
Safety Precautions ...............................................................................6  
Serial Number..........................................................................................2  
Source Selection Buttons..............................................................7  
Terminations..............................................................................................14  
Troubleshooting......................................................................................20  
Ventilation.....................................................................................................4, 13  
Volume Control........................................................................................7  
Warm-Up Period.....................................................................................16  
22  
PLINIUS ANNIVERSARY  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Philips CD Player AZ1007 01 User Manual
Philips Clock Radio AJ3977 37 User Manual
Philips Flat Panel Television 150MT20P User Manual
Philips Headphones SWS2000 00 User Manual
Philips Projection Television 55PP9753 17 User Manual
Philips Satellite TV System DTR 100 User Manual
Polaroid Photo Printer DIGITAL PHOTO PRINTER User Manual
Poulan Trimmer RTE115 User Manual
Poulan Trimmer TE400CXL User Manual
Powerware Power Supply UPS 1000 2200 User Manual