4-Port 10/100Mbps +1/2 100FX Fiber Port
Industrial Fast Ethernet Switch
ISW-511 / ISW-621Series
User's Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
communications. Operation of this equipment in a residential area
is likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
CE Mark Warning
This is a Class A product. In a domestic environment, this product may
cause radio interference, in which case the user may be required to
take adequate measures.
WEEE Warning
To avoid the potential effects on the environment and human
health as a result of the presence of hazardous substances in
electrical and electronic equipment, end users of electrical
and electronic equipment should understand the meaning of
the crossed-out wheeled bin symbol. Do not dispose of WEEE as
unsorted municipal waste and have to collect such WEEE separately.
Revision
PLANET 4-Port 10/100Mbps +1/2 100FX Fiber Port Industrial Fast
Ethernet Switch User’s Manual
For Models: ISW-511 / ISW-621 Series
Revision: 1.0 (February, 2009)
Part No: EM-ISW-511_621_v1.0 (2350-AH0150-000)
Download from Www.Somanuals.com. All Manuals Search And Download.
TABLE OF CONTENTS
1. INTRODUCTION ........................................................................ 6
1.1 Package Contents ............................................................... 6
1.2 How to Use This Manual ..................................................... 6
1.3 Product Features................................................................. 7
Physical Port....................................................................... 7
Layer 2 Features................................................................. 7
Industrial Case / Installation................................................ 8
1.4 Product Specifications ......................................................... 9
2. INSTALLATION .........................................................................13
2.1 Product Description.............................................................13
2.1.1 Switch Front Panel ....................................................14
2.1.2 LED Indicators ..........................................................16
2.1.3 Switch Upper Panel ...................................................16
2.1.4 Wiring the Power Inputs ............................................17
2.1.5 Wiring the Fault Alarm Contact...................................18
2.2 Mounting Installation ..........................................................19
2.2.1 Install DIN-Rail Mounting...........................................19
2.2.2 Wall Mount Plate Mounting.........................................21
3
APPLICATION...........................................................................22
Installation Steps...............................................................23
Download from Www.Somanuals.com. All Manuals Search And Download.
4. SWITCH OPERATION.................................................................24
4.1 Address Table....................................................................24
4.2 Learning ...........................................................................24
4.3 Forwarding & Filtering........................................................24
4.4 Store-and-Forward.............................................................24
4.5 Auto-negotiation................................................................25
5. TROUBLESHOOTING .................................................................26
APPENDIX A: NETWORKING CONNECTION.......................................27
A.1 Switch’s RJ-45 Pin Assignments ..........................................27
A.2 RJ-45 cable Pin Assignments ..............................................27
Download from Www.Somanuals.com. All Manuals Search And Download.
1. INTRODUCTION
1.1 Package Contents
Check the contents of your package for following parts:
● Industrial Fast Ethernet Switch x 1
● User's Manual x 1
● DIN Rail Kit x 1
● Wall Mount Kit x 1
If any of these are missing or damaged, please contact your dealer
immediately, if possible, retain the carton including the original packing
material, and use them against to repack the product in case there is a
need to return it to us for repair.
1.2 How to Use This Manual
This Industrial Fast Ethernet Switch User Manual is structured as
follows:
Chapter 2 Installation
The chapter explains the feature, functionality and the physical
installation of the Industrial Fast Ethernet Switch.
Chapter 3 Application
The chapter explains the Industrial Fast Ethernet Switch application.
Chapter 4 Switch operation
The chapter explains the Industrial Fast Ethernet Switch transmit
operation.
Chapter 5 Troubleshooting
The chapter explains the troubleshooting of the Industrial Fast Ethernet
Switch.
Appendix A
This chapter contains cable information of the Industrial Fast Ethernet
Switch.
ꢀ
Download from Www.Somanuals.com. All Manuals Search And Download.
1.3 Product Features
Physical Port
Fiber Optical
Interface
Ports
Model
Name
Copper
Optical
Mode Distance
ISW-511
Multi-
2km
mode
ISW-511T
1 x 100Base-FX
2 x 100Base-FX
ISW-511S15
ISW-511TS15
ISW-621
Single-
15km
mode
4 x 10/100Base-TX
Multi-
2km
mode
ISW-621T
ISW-621S15
ISW-621TS15
Single-
15km
mode
Layer 2 Features
□ Complies with IEEE 802.3, IEEE 802.3u 10/100Base-TX, 100Base-FX
□ Supports Auto-negotiation and 10/100Mbps half / full duplex mode
for each copper port
□ High performance store and forward architecture, broadcast storm
control, runt/CRC filtering eliminates erroneous packets to optimize
the network bandwidth
□ Prevents packet loss with back pressure (Half-Duplex) and IEEE
802.3x PAUSE frame flow control (Full-Duplex)
□ Backplane (Switching Fabric): ISW-511 Series: 1Gbps, ISW-621
Series: 1.2Gbps
□ Integrated address look-up engine, support 2K absolute MAC
addresses
□ 1Mbit on-chip frame buffer on ISW-511 / ISW-621 Series
□ Automatic address learning and address aging
ꢁ
Download from Www.Somanuals.com. All Manuals Search And Download.
□ CSMA/CD Protocol
Industrial Case / Installation
□ IP-30 Metal case / Protection
□ DIN Rail and Wall Mount Design
□ 12 to 48V DC, redundant power with polarity reverse protect function
and connective removable terminal block for master and slave power
□ -10 to 60 Degree C operation temperature on ISW-511 / ISW-
511S15 / ISW-621 / ISW-621S15
□ -40 to 75 Degree C operation temperature on ISW-511T / ISW-
511TS15 / ISW-621T / ISW-621TS15
ꢂ
Download from Www.Somanuals.com. All Manuals Search And Download.
1.4 Product Specifications
Model
ISW-511
ISW-511S15
Hardware Specification
Ports
4 x 10/100Base-TX, Auto-negotiation, Auto-MDI/MDI-X
10Base-T: 2-pair UTP Cat. 3, 4, 5 cable (100meters, max.)
100Base-TX: 2-pair UTP Cat. 5 cable (100meters, max.)
1 x 100Base-FX
Copper
Cable
Port
Cable
Mode
Distance
50/125μm or 62.5/125μm fiber 9/125μm fiber
Fiber
Optical
Multi-mode
2km
Single-mode
15km
Dimensions
(W x D x H)
Weight
135mm x 97mm x 32mm
436g
12~48 VDC,
Power Requirement
Redundant power with polarity reverse protection function
Power Consumption
/ Dissipation
9.1 Watts / 31BTU
Installation
DIN rail kit and wall mount ear
Switch Specification
Switch Processing
Scheme
Store-and-Forward
Address Table
Buffer
2K entries
1Mbit
Back pressure for half duplex,
IEEE 802.3x Pause Frame for full duplex
1Gbps
Flow Control
Switch Fabric
Throughput
(Packet Per Second)
0.74Mpps @ 64Bytes
Standards Conformance
IEEE 802.3 Ethernet, 10Base-T
IEEE 802.3u Fast Ethernet, 100Base-TX, 100Base-FX
IEEE 802.3x Full-duplex flow control
Standards
Compliance
Operating: -10~60 Degree C
Storage: -40~85 Degree C
Temperature
Humidity Operating
Regulation
Compliance
Operating: 5% to 90%, Storage: 5% to 90% (Non-condensing)
FCC Part 15 Class A, CE
ꢃ
Download from Www.Somanuals.com. All Manuals Search And Download.
Model
ISW-511T
ISW-511TS15
Hardware Specification
Ports
4 x 10/100Base-TX, Auto-negotiation, Auto-MDI/MDI-X
10Base-T: 2-pair UTP Cat. 3, 4, 5 cable (100meters, max.)
100Base-TX: 2-pair UTP Cat. 5 cable (100meters, max.)
1 x 100Base-FX
Copper
Cable
Port
Cable
Mode
Distance
50/125μm or 62.5/125μm fiber 9/125μm fiber
Fiber
Optical
Multi-mode
2km
Single-mode
15km
Dimensions
(W x D x H)
Weight
135mm x 97mm x 32mm
436g
12~48 VDC,
Power Requirement
Redundant power with polarity reverse protection function
Power Consumption
/ Dissipation
9.1 Watts / 31BTU
Installation
DIN rail kit and wall mount ear
Switch Specification
Switch Processing
Scheme
Store-and-Forward
Address Table
Buffer
2K entries
1Mbit
Back pressure for half duplex,
IEEE 802.3x Pause Frame for full duplex
1Gbps
Flow Control
Switch Fabric
Throughput
(Packet Per Second)
0.74Mpps @ 64Bytes
Standards Conformance
IEEE 802.3 Ethernet, 10Base-T
IEEE 802.3u Fast Ethernet, 100Base-TX, 100Base-FX
IEEE 802.3x Full-duplex flow control
Standards
Compliance
Operating: -40~75 Degree C
Storage: -40~85 Degree C
Temperature
Humidity Operating
Regulation
Compliance
Operating: 5% to 90%, Storage: 5% to 90% (Non-condensing)
FCC Part 15 Class A, CE
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Model
ISW-621
ISW-621S15
Hardware Specification
Ports
4 x 10/100Base-TX, Auto-negotiation, Auto-MDI/MDI-X
10Base-T: 2-pair UTP Cat. 3, 4, 5 cable (100meters, max.)
100Base-TX: 2-pair UTP Cat. 5 cable (100meters, max.)
2 x 100Base-FX
Copper
Cable
Port
Cable
Mode
Distance
50/125μm or 62.5/125μm fiber 9/125μm fiber
Fiber
Optical
Multi-mode
2km
Single-mode
15km
Dimensions
(W x D x H)
Weight
135mm x 97mm x 32mm
442g
12~48 VDC,
Power Requirement
Redundant power with polarity reverse protection function
Power Consumption
/ Dissipation
11.6 Watts / 40BTU
Installation
DIN rail kit and wall mount ear
Switch Specification
Switch Processing
Scheme
Store-and-Forward
Address Table
Buffer
2K entries
1Mbit
Back pressure for half duplex,
IEEE 802.3x Pause Frame for full duplex
1.2Gbps
Flow Control
Switch Fabric
Throughput
(Packet Per Second)
0.89Mpps @ 64Bytes
Standards Conformance
IEEE 802.3 Ethernet, 10Base-T
IEEE 802.3u Fast Ethernet, 100Base-TX, 100Base-FX
IEEE 802.3x Full-duplex flow control
Standards
Compliance
Operating: -10~60 Degree C
Storage: -40~85 Degree C
Temperature
Humidity Operating
Regulation
Compliance
Operating: 5% to 90%, Storage: 5% to 90% (Non-condensing)
FCC Part 15 Class A, CE
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Model
ISW-621T
ISW-621TS15
Hardware Specification
Ports
4 x 10/100Base-TX, Auto-negotiation, Auto-MDI/MDI-X
10Base-T : 2-pair UTP Cat. 3, 4, 5 cable (100meters, max.)
100Base-TX : 2-pair UTP Cat. 5 cable (100meters, max.)
2 x 100Base-FX
Copper
Cable
Port
Cable
Mode
Distance
50/125μm or 62.5/125μm fiber 9/125μm fiber
Fiber
Optical
Multi-mode
2km
Single-mode
15km
Dimensions
(W x D x H)
Weight
135mm x 97mm x 32mm
442g
12~48 VDC,
Power Requirement
Redundant power with polarity reverse protection function
Power Consumption
/ Dissipation
11.6 Watts / 40BTU
Installation
DIN rail kit and wall mount ear
Switch Specification
Switch Processing
Scheme
Store-and-Forward
Address Table
Buffer
2K entries
1Mbit
Back pressure for half duplex,
IEEE 802.3x Pause Frame for full duplex
1.2Gbps
Flow Control
Switch Fabric
Throughput
(Packet Per Second)
0.89Mpps @ 64Bytes
Standards Conformance
IEEE 802.3 Ethernet, 10Base-T
IEEE 802.3u Fast Ethernet, 100Base-TX, 100Base-FX
IEEE 802.3x Full-duplex flow control
Standards
Compliance
Operating: -40~75 Degree C
Storage: -40~85 Degree C
Temperature
Humidity Operating
Regulation
Compliance
Operating: 5% to 90%, Storage: 5% to 90% (Non-condensing)
FCC Part 15 Class A, CE
12
Download from Www.Somanuals.com. All Manuals Search And Download.
2. INSTALLATION
This section describes the functionalities of the Industrial Fast Ethernet
Switch’s components and guides how to install it on the desktop.
Basic knowledge of networking is assumed. Please read this chapter
completely before continuing.
In the following section, the term “Industrial Fast Ethernet Switch”
means the ISW-511 / ISW-621 series.
2.1 Product Description
The PLANET ISW-511 / ISW-621 series is 4-Port 10/100Mbps + 1/2
100FX Fiber Port Industrial Fast Ethernet Switch with non-blocking wire-
speed performance and new slim type with IP 30 metal shape for easily
deployment in Heavy Industrial demanding environments.
With a 1/1.2Gbps internal switching fabric, the Industrial Fast Ethernet
Switch can handle extremely large amounts of data in a secure
topology linking to a backbone or high capacity servers.
The Industrial Fast Ethernet Switch has 2K MAC address table and
offers wire-speed packets transfer performance without risk of packet
loss. The stable throughput of the device makes it ideal for most
Ethernet environments.
All RJ-45 copper interfaces support 10/100Mbps Auto-negotiation for
optimal speed detection through RJ-45 Category 5, 4 or 3 cables.
Support standard for Auto-MDI/MDI-X that can detect the type of
connection to any Ethernet device without requiring special straight or
crossover cables.
The flow control function allows Industrial Fast Ethernet Switch
supported routers and servers to directly connect to this device for fast,
reliable data transfer.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
2.1.1 Switch Front Panel
Figure 2-1 & 2-2 & 2-3 & 2-4 shows a front panel of Industrial Fast
Ethernet Switch.
Figure 2-1 ISW-511 / ISW-511S15 front panel
Figure 2-2 ISW-621 / ISW-621S15 front panel
14
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 2-3 ISW-511T / ISW-511TS15 front panel Figure 2-4 ISW-621T / ISW-621TS15 front panel
15
Download from Www.Somanuals.com. All Manuals Search And Download.
2.1.2 LED Indicators
LED
Color
Function
P1
P2
Green Lit: indicate the power 1 has power.
Green Lit: indicate the power 2 has power.
Lit: indicate the either power 1 or power 2 has no
FAULT
Green
power.
Lit: indicate the Fiber port is successfully
Fiber
Optical
100
Green
connecting to the network at
100Mbps.
Lit: indicate the Switch is successfully
connecting to the network at
100Mbps.
Off: indicate that the Switch is
successfully connecting to the
network at 10Mbps.
10/100
Green Copper
Lit: indicate the link through that port is
successfully established.
Fiber
Optical
LNK/ACT Green
Blink: indicate that the Switch is actively
sending or receiving data over that
port.
Copper
2.1.3 Switch Upper Panel
The upper panel of the Industrial Fast Ethernet Switch consist one
terminal block connector within two DC power inputs. Figure 2-5 shows
the upper panel of the Industrial Fast Ethernet Switch.
Figure 2-5 Industrial Fast Ethernet Switch upper Panel.
1ꢀ
Download from Www.Somanuals.com. All Manuals Search And Download.
2.1.4 Wiring the Power Inputs
The 6-contact terminal block connector on the top panel of Industrial
Fast Ethernet Switch is used for two DC redundant powers input. Please
follow the steps below to insert the power wire.
1.Insert positive / negative DC power wires into the contacts 1 and 2
for POWER 1, or 5 and 6 for POWER 2.
V1- V1 +
V2 - V2 +
2.Tighten the wire-clamp screws for preventing the wires from
loosing.3.
1
2
+
3
4
5
6
+
Power 1
-
Fault
Power 2
-
The wire gauge for the terminal block should be in the
range between 12 ~ 24 AWG.
Note
1ꢁ
Download from Www.Somanuals.com. All Manuals Search And Download.
2.1.5 Wiring the Fault Alarm Contact
The fault alarm contacts are in the middle of the terminal block
connector as the picture shows below. Inserting the wires, the Industrial
Fast Ethernet Switch will detect the fault status of the power failure,
or port link failure (available for managed model) and then forms an
open circuit. The following illustration shows an application example for
wiring the fault alarm contacts.
1
2
3
4
5
6
Insert the wires into the fault alarm contacts
1. The wire gauge for the terminal block should be in
the range between 12 ~ 24 AWG.
2. Alarm relay circuit accepts up to 30V, max. 3A
currents.
Note
1ꢂ
Download from Www.Somanuals.com. All Manuals Search And Download.
2.2 Mounting Installation
This section describes how to install the Industrial Fast Ethernet Switch
and make connections to it. Please read the following topics and
perform the procedures in the order being presented.
In the installation steps below, this Manual use IGS-
801 (PLANET 8 Port Industrial Gigabit Switch) as the
example. However, the steps for PLANET Industrial
Note
Switch & Industrial Media Converter are similar.
2.2.1 Install DIN-Rail Mounting
The DIN-Rail is screwed on the Industrial Fast Ethernet Switch when
out of factory. When need to replace the wall mount application with
DIN-Rail application on Industrial Fast Ethernet Switch , please refer to
following figures to screw the DIN-Rail on the Industrial Fast Ethernet
Switch. To hang the Industrial Fast Ethernet Switch, follow the below
steps:
Step 1: screw the DIN-Rail on the Industrial Fast Ethernet Switch.
1ꢃ
Download from Www.Somanuals.com. All Manuals Search And Download.
1
2
Step 2: Lightly press the button of DIN-Rail into the track.
Step 3: Check the DIN-Rail is tightly on the track.
Step 4: Please refer to following procedures to remove the Industrial
Fast Ethernet Switch from the track.
1
2
Step 5: Lightly press the button of DIN-Rail for remove it from the
track.
20
Download from Www.Somanuals.com. All Manuals Search And Download.
2.2.2 Wall Mount Plate Mounting
To install the Industrial Fast Ethernet Switch on the wall, please follows
the instructions described below.
Step 1: Remove the DIN-Rail from the Industrial Fast Ethernet
Switch; loose the screws to remove the DIN-Rail.
Step 2: Place the wall mount plate on the rear panel of the Industrial
Fast Ethernet Switch.
Step 3: Use the screws to screw the wall mount plate on the
Industrial Fast Ethernet Switch.
Step 4: Use the hook holes at the corners of the wall mount plate to
hang the Industrial Fast Ethernet Switch on the wall.
Step 5: To remove the wall mount plate, reverse steps above.
21
Download from Www.Somanuals.com. All Manuals Search And Download.
3. AppLICATION
In this paragraph, we will describe how to install Industrial Fast
Ethernet Switch and the installation points for the attention.
Fiber Switch
ISW-511S15
100
15km
100
15km
Serial Device
Server
ISW-511S15
15km
100
ICA-525
Control Center
ICA-651
ICA-350
ICS-2100
I/O
ISW-511S15
PLC
ICS-2100
I/O
Harbor
Warehouse
PLC
ICA-310
I/O
I/O
Robot
ROBOT
ROBOT
Robot
100Base-TX UTP
100
I/O
100Base-FX Fiber-optic
DI/DO
Factory
Fiber Switch
ISW-621S15
ISW-621S15
ICS-2100
100
Serial over Ethernet
device
15km
15km
15km
ICA-601
100
100
ICA-525
I/O
ICS-2100
PLC
I/O
Control Center
PLC
I/O
I/O
I/O
I/O
Robot
I/O
ISW-621S15
ROBOT
ROBOT
Robot
I/O Device
Subway 2
Maintenance Shop
ICA-310
100Base-TX UTP
100
100Base-FX Fiber-optic
DI/DO
I/O
Subway 1
22
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Steps
Step 1: Unpack the Industrial Fast Ethernet Switch.
Step 2: Check the DIN-Rail is screwed on the Industrial Fast Ethernet
Switch. (Please refer to DIN-Rail Mounting section for DIN-
Rail installation. If the DIN-Rail is not screwed on the
Industrial Fast Ethernet Switch.). If you want to wall mount
the Industrial Fast Ethernet Switch, then please refer to
Wall Mount Plate Mounting section for wall mount plate
installation.
Step 3: To hang the Industrial Fast Ethernet Switch on the DIN-
Rail track or wall, please refer to the Mounting Installation
section.
Step 4: Power on the Industrial Fast Ethernet Switch. (Please refer
to the Wiring the Power Inputs section for power input) The
power LED on the Industrial Fast Ethernet Switch will light
up. Please refer to the LED Indicators section for meaning of
LED lights.
Step 5: Prepare the twisted-pair, straight through Category 5 cable
for Ethernet connection.
Step 6: Insert one side of Category 5 cables into the Industrial Fast
Ethernet Switch Ethernet port (RJ-45 port) and another side
of category 5 cables to the network devices’ Ethernet port
(RJ-45 port), ex: Switch, PC or Server. The UTP port (RJ-45)
LED on the Industrial Fast Ethernet Switch will light up when
the cable connected with the network device. Please refer to
the LED Indicators section for LED light meaning.
Be sure the connected network devices support MDI/
MDI-X. If it does not support then use the crossover
category 5 Cable.
Note
Step 7: Insert fiber cable from the ISW-511/621 series to the fiber
network. TX, RX must be paired at both ends. The optical
port LED on the Industrial Fast Ethernet Switch will light up
when the cable connected with the network device. Please
refer to the LED Indicators section for LED light meaning.
Step 8: When all connections are all set and LED lights all show in
normal, the installation is complete.
23
Download from Www.Somanuals.com. All Manuals Search And Download.
4. SwITCh OpeRATION
4.1 Address Table
The Industrial Fast Ethernet Switch is implemented with an address
table. This address table composed of many entries. Each entry is used
to store the address information of some node in network, including
MAC address, port no, etc. This information comes from the learning
process of Industrial Fast Ethernet Switch.
4.2 Learning
When one packet comes in from any port. The Industrial Fast Ethernet
Switch will record the source address, port no. And the other related
information in address table. This information will be used to decide
either forwarding or filtering for future packets.
4.3 Forwarding & Filtering
When one packet comes from some port of the Industrial Fast Ethernet
Switch, it will also check the destination address besides the source
address learning. The Industrial Fast Ethernet Switch will lookup the
address-table for the destination address. If not found, this packet will
be forwarded to all the other ports except the port which this packet
comes in. And these ports will transmit this packet to the network it
connected. If found, and the destination address is located at different
port from this packet comes in, the Industrial Fast Ethernet Switch will
forward this packet to the port where this destination address is located
according to the information from address table. But, if the destination
address is located at the same port with this packet comes in, then
this packet will be filtered. Thereby increasing the network throughput
and availability.
4.4 Store-and-Forward
Store-and-Forward is one type of packet-forwarding techniques. A
Store-and-Forward Industrial Switch stores the incoming frame in an
internal buffer, do the complete error checking before transmission.
24
Download from Www.Somanuals.com. All Manuals Search And Download.
Therefore, no error packets occurrence, it is the best choice when a
network needs efficiency and stability.
The Industrial Fast Ethernet Switch scans the destination address from
the packet-header, searches the routing table provided for the incoming
port and forwards the packet, only if required. The fast forwarding
makes the switch attractive for connecting servers directly to the
network, thereby increasing throughput and availability. However, the
switch is most commonly used to segment existing hubs, which nearly
always improves overall performance. An Ethernet Switching can be
easily configured in any Ethernet network environment to significantly
boost bandwidth using conventional cabling and adapters.
Due to the learning function of the Industrial Fast Ethernet Switch,
the source address and corresponding port number of each incoming
and outgoing packet are stored in a routing table. This information is
subsequently used to filter packets whose destination address is on the
same segment as the source address. This confines network traffic to
its respective domain, reducing the overall load on the network.
The Industrial Fast Ethernet Switch performs “Store-and-Forward"
therefore, no error packets occur. More reliably, it reduces the re-
transmission rate. No packet loss will occur.
4.5 Auto-negotiation
The STP ports on the Industrial Fast Ethernet Switch have built-
in “Auto-negotiation”. This technology automatically sets the best
possible bandwidth when a connection is established with another
network device (usually at Power On or Reset). This is done by detect
the modes and speeds at the second of both device is connected and
capable of, both 10Base-T and 100Base-TX devices can connect with
the port in either Half- or Full-Duplex mode.
25
Download from Www.Somanuals.com. All Manuals Search And Download.
5. TROUBLeShOOTING
This chapter contains information to help you solve issues. If the
Industrial Fast Ethernet Switch is not functioning properly, make sure
the Industrial Fast Ethernet Switch was set up according to instructions
in this manual.
The per port LED is not lit
Solution:
Check the cable connection of the Industrial Fast Ethernet Switch.
Performance is bad
Solution:
Check the speed duplex mode of the partner device. The Industrial Fast
Ethernet Switch is run at Auto-negotiation mode and if the partner is
set to half duplex, then the performance will be poor.
Per port LED is lit, but the traffic is irregular
Solution:
Check that the attached device is not set to dedicate full duplex. Some
devices use a physical or software switch to change duplex modes.
Auto-negotiation may not recognize this type of full-duplex setting.
Why the Industrial Fast Ethernet Switch doesn’t connect to the
network
Solution:
Check per port LED on the Industrial Fast Ethernet Switch. Try another
port on the Industrial Fast Ethernet Switch Make sure the cable is
installed properly Make sure the cable is the right type Turn off the
power. After a while, turn on power again.
Why the Industrial Fast Ethernet Switch doesn’t connect to the
network
Solution:
Check per port LED on the Industrial Fast Ethernet Switch. Try another
port on the Industrial Fast Ethernet Switch Make sure the cable is
installed properly Make sure the cable is the right type Turn off the
power. After a while, turn on power again.
2ꢀ
Download from Www.Somanuals.com. All Manuals Search And Download.
AppeNDIX A: NeTwORKING CONNeCTION
A.1 Switch’s RJ-45 Pin Assignments
10/100Mbps, 10/100Base-TX
RJ-45 Connector pin assignment
MDI-X
MDI
Contact
Media Dependant Interface
-Cross
Media Dependant Interface
1
2
Tx + (transmit)
Tx - (transmit)
Rx + (receive)
Rx + (receive)
Rx - (receive)
Tx + (transmit)
3
4, 5
6
Not used
Rx - (receive)
Tx - (transmit)
7, 8
Not used
A.2 RJ-45 cable Pin Assignments
The standard RJ-45 receptacle/connector
There are 8 wires on a standard UTP/STP cable and each wire is color-
coded. The following shows the pin allocation and color of straight cable
and crossover cable connection:
2ꢁ
Download from Www.Somanuals.com. All Manuals Search And Download.
Straight Cable
1 2 3 4 5 6 7 8
SIDE 1
SIDE 2
SIDE 1
SIDE 2
1 = White/Orange
2 = Orange
3 = White/Green
4 = Blue
5 = White/Blue
6 = Green
1 = White/Orange
2 = Orange
3 = White/Green
4 = Blue
5 = White/Blue
6 = Green
1 2 3 4 5 6 7 8
7 = White/Brown
8 = Brown
7 = White/Brown
8 = Brown
Cross Over Cable
SIDE 1
SIDE 2
SIDE 1
1 2 3 4 5 6 7 8
1 = White/Orange
2 = Orange
1 = White/Green
2 = Green
3 = White/Green
4 = Blue
5 = White/Blue
6 = Green
3 = White/Orange
4 = Blue
5 = White/Blue
6 = Orange
1 2 3 4 5 6 7 8
SIDE 2
7 = White/Brown
8 = Brown
7 = White/Brown
8 = Brown
Figure A-1: Straight-Through and Crossover Cable
Please make sure your connected cables are with same pin assignment
and color as above picture before deploying the cables into your
network.
2ꢂ
Download from Www.Somanuals.com. All Manuals Search And Download.
|