TABLE OF CONTENTS
1. UNPACKING INFORMATION...........................................5
2. PRODUCT INTRODUCTION .............................................7
2.1 KEY FEATURES ....................................................................7
2.2 FRONT PANEL......................................................................8
2.2.1 Ports Speed..................................................................8
2.2.2 Cabling ......................................................................8
2.2.3 MDI Switch..................................................................9
2.2.4 Status LEDs.................................................................9
2.3 THE REAR PANEL............................................................... 10
2.3.1 Extension Slot............................................................ 10
2.3.2 Power Connector ....................................................... 10
2.3.3 Fan
.................................................................... 10
2.3.4 RS-232 Console ......................................................... 11
3. INSTALLATION ................................................................ 13
3.1 RACK-MOUNT INSTALLATION ............................................ 13
3.2 DESKTOP INSTALLATION .................................................... 13
3.3 POWER NOTES: .................................................................. 14
4. CONSOLE CONFIGURATION......................................... 15
4.1 CONNECT TO PC ........................................................... 15
4.2 TRUNK/ VLAN SETTING.................................................... 16
4.2.1 Trunking Group Setting ............................................. 16
4.2.2 VLAN Group Setting .................................................. 17
4.3 PORT STATUS .................................................................... 19
4.4 PORT SETTING................................................................... 19
4.5 FACTORY SETTING............................................................. 20
4.6 REDUNDANT LINK SETTING................................................ 21
4.7 SAVE SETTING ................................................................... 21
5. OPTIMIZING CONFIGURATION ................................... 23
5.1 PRIOR TO INSTALLATION .................................................... 23
FNSW-16/2400S User's Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
5.2 HALF- AND FULL-DUPLEX .................................................. 23
5.3 FAST ETHERNET ................................................................ 24
5.4 AUTO-NEGOTIATION.......................................................... 25
5.5 MAC ADDRESS TABLE ...................................................... 25
5.6 SAMPLE APPLICATION........................................................ 26
6. TROUBLESHOOTING...................................................... 27
7. PRODUCT SPECIFICATIONS.......................................... 29
8. RJ-45 PIN ASSIGNMENT.................................................. 30
8.1 STRAIGHT-THROUGH/CROSSOVER CABLE........................... 30
PLANET NOVASwitch series
Download from Www.Somanuals.com. All Manuals Search And Download.
1.UNPACKING INFORMATION
Thank you for purchasing a PLANET NOVASwitch series
Ethernet Switches. Before continuing, please check the
contents of the product package. This product package should
contain the following items:
·
·
·
·
·
One NOVASwitch Ethernet Switch
One Power Cord
Two Rack-Mounting Brackets with Attachment Screws
This User’s Guide
RS-232 Console Cable
Please inform your local dealer/supplier immediately if any item
is found to be defective, damaged or missing. Retain the
original packaging (carton), including the packing materials,
and use them to re-pack the product in the unlikely event there
is a need to return it to us for repair.
.
5
FNSW-16/2400S User's Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
This page intentionally left blank!
PLANET NOVASwitch series
Download from Www.Somanuals.com. All Manuals Search And Download.
2.PRODUCT INTRODUCTION
NOVASwitch Ethernet Switches are multi-speed, versatile
network devices combining both standard and "Big-Pipe" ports
under the same hood.
2.1 Key Features
·
·
·
·
Compliant with IEEE802.3 and 802.3u standards for
10Base-T / 100Base-TX/FX.
16-port/24-port Fast Ethernet Switch, pure 10/100Base-
TX
Wire-speed "Store-and-Forward" filtering/forwarding
eliminates bad data packets with minimal delay
100Base-TX ports automatically sense and set optimal
line speed from 10/20, 100/200Mbps, All 100Base-TX port
support MII Auto-Negotiation function
·
·
Optional Fiber-optic module for 100Base-FX, shared with
port16/24. DIP switch for Half/Full-Duplex selection
Shared buffer memory and up to 2K-entry MAC source
address table make for fast handling of data packets
·
·
Flow control to eliminate packets loss
Internal, full-range power supply suitable for worldwide
use
·
·
·
·
·
Console port for switch basic management
Either VLAN or Turnk port support managed via console
Up to four port-based VLAN support
Up to four trunk support for up to 800Mbps bandwidth
One Redundant link support
7
FNSW-16/2400S User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
2.2 Front Panel
FNSW-1600S
Figure 1: Front View of the FNSW-16/2400S
2.2.1 Ports Speed
n
100Base-TX
All 100Base-TX ports come with auto-negotiation capability.
They automatically support 100Base-TX and 10Base-T
networks. Users only need to plug a working network device
into one of the 100Base-TX ports, then turn on the hub. The
port will automatically runs in 10Mbps, 20Mbps, 100Mbps or
200Mbps after the negotiation with the connected device.
Port speed adjustment is also available through console port.
n
100Base-FX
The port 16/24 can be a 100Base-FX fiber-optic port as the
extension module installed (rear) At the mean time, the RJ-
45 port of #16/24 will being disabled. The Half-/Full-Duplex is
selectable by the DIP-switch on the module. Please refer to
the installation guide of the extension module for more.
2.2.2 Cabling
NOVASwitch 100Base-TX ports use RJ-45 sockets -- similar to
phone jacks -- for connection of unshielded twisted-pair cable
(UTP). The IEEE 802.3u Fast Ethernet standard requires
Category 5 UTP for 100Mbps 100Base-TX. 10Base-T networks
can use Cat.3, 4, or 5 UTP (see table A below)
8
PLANET NOVASwitch series
Download from Www.Somanuals.com. All Manuals Search And Download.
Port Type
Cable Type
Connector
Cat 3, 4, 5
RJ-45
10Base-T
Cat.5 UTP only
RJ-45
100Base-TX
100Base-FX*
ST / SC
62.5/125mm multi-mode fiber
Table A: Supported port list
23
24
2.2.3 MDI Switch
Reset
19
20
Each numbered port of the Switch are MDI-X port, you can
direct use straight cable for the connection to your end nodes.
However, port 12/20 is with one push button. To push the button
to convert the port to MDI-II port for direct hub cascade. Please
also refer to Section “RJ-45 Pin Assignment” for more.
2.2.4 Status LEDs
One green LED to show power On/Off is on the front panel, and one
“Module Installed” LED indicator to indicate the rear open slot is
installed with a fiber-optic module. Also, each port has three status
LED indicators, as shown below.
STATUS /
COLOR
LABEL
MEANING DESCRIPTION
FDX
Steady
Amber
UPPER
ROW
Lit to indicate Full-Duplex mode
detected on that port
COL
Link
Blink
Amber
Blinks if a collision is detected
when the port is in Half-Duplex
mode.
Steady
Green
Lit to indicate that a valid physical
UTP/STP connection is detected
MIDDLE
ROW
Activity Blink to indicate the port is
receiving data packets
Blink
Green
9
FNSW-16/2400S User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
100M
10M
Steady
Green
Lit to indicate that a valid physical
UTP/STP connection exists on
that port runs in 100Mbps
LOWER
ROW
Remains off and Link ON to
OFF
indicate the port runs in 10Mbps
Table B: FNSW-2400S Port-LED Functions
2.3 The Rear Panel
Figure 2: Rear View of the Switch
2.3.1 Extension Slot
The Switch port 16/24 can be a 100Base-FX switching port as the
extension module installed. As the module installed, the port 16/24
on the front panel will be disabled.
Please refer to the Installation Guide of the module for the detailed
installation and settings.
NOTE: While powering on, The Switch detects the DIP-
switch status of the module, then shown on the
front panel LED indicators
2.3.2 Power Connector
The Power Connector is designed to use with the power cord
included in the product package. Attach the female end of the
cord to the power connector and the male end of the cord to a
grounded power outlet. The accepted power range is from
100VAC to 240VAC, 50/60Hz.
2.3.3 Fan
All computing and communications devices work best when not
overheated. Please keep the fan area clear so that the cooling
function is not impaired.
10
PLANET NOVASwitch series
Download from Www.Somanuals.com. All Manuals Search And Download.
2.3.4 RS-232 Console
The RS-232 console helps to manage the Switch. Please use
the cable with the package. Attach one end to the switch and
the other to your PC’s COM1 or COM2. Then startup your
console program like Windows Hyper Terminal, or ProCOMM
with parameter: 19200, n, 8, 1. Please refer to Chapter 4,
Console management for more.
11
FNSW-16/2400S User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
This page intentionally left blank!
12
PLANET NOVASwitch series
Download from Www.Somanuals.com. All Manuals Search And Download.
3. INSTALLATION
The Switch do NOT require software configuration. Users can
immediately use any of the features of this product simply by
attaching the cables and turning on the power. However, the
Console port will helps to have more setting to your Switch.
To get the best use of the Switch, many things need to be
considered first. See Chapter 5 for details.
3.1 Rack-Mount Installation
Most users prefer to attach the power cord to the hub before
installation in a network rack. Do not plug the other end of the
cord into a power outlet until after the hub is installed.
For mounting the Switch in a network rack, first attach the
rack-mount brackets to the side of the hub with screws. (Both
brackets and screws are included in the product package.) Slide
the hub into the rack and align the holes in the bracket with the
corresponding holes in the network rack. Attach the bracket to
the rack with the enclosed screws.
3.2 Desktop Installation
To locate the Switch on a desktop, first attach the four rubber
feet to the bottom of the hub, one in each corner. Place the hub
on a clean, flat desk or table-top close to a power outlet. Make
sure there is no hindrance behind the fan of the hub
Plug in all network connections, then turn the switch on via plug
in the power cord.
13
FNSW-16/2400S User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
3.3 Power notes:
1. The device is a power-required device, it means, it will not
work till it is powered. If your networks should active all the
time, please consider use an UPS (Uninterrupted Power
Supply) for your device. It will prevent you from network data
loss or network downtime.
2. In some area, installing a surge suppression device may
also help to protect your hub from being damaged by
unregulated surge or current to the Switch or the power
adapter.
14
PLANET NOVASwitch series
Download from Www.Somanuals.com. All Manuals Search And Download.
4.CONSOLE CONFIGURATION
On the rear panel, there is one console port for configuring the switch.
The attached cable in the packing box is used to connect to PC’s
RS232C port (COM1, or COM2). Following the instructions below to
configure the switch.
4.1 CONNECT TO PC
RS-232 serial cable
Attach the RS-232 cable 9-pin female connector to the male
connector on the demo board. Plug the other side of this cable
to your PC.
Hyper Terminal
In Window 95/98, launch “HyperTerminal”, create a new
connection and adjust setting as below:
Baud Rate:
Data byte:
19200bps
8 bits
Parity check: None
Stop bit:
Flow Control: No
1
Console Menu
Launch the new terminal you just set up, and then, turn on the
Switch. See the following messages for successful connection.
15
FNSW-16/2400S User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
There are six options available for the console setup:
(1) Trunk / VLAN Setting
(2) Port Status
(3) Port Setting
(4) Factory Setting
(5) Redundant Link
(6) Save Setting
To enter any of the sub-menu, simply follow the instruction and
type the number on the command line, and press ENTER.
4.2 Trunk/ VLAN Setting
Entry:
Select “1” from <Console Menu>
(1) Trunking (2) VLAN Setting (3) Exit >>
Purpose:
Set up the TRUNKING or VLAN Group
Be noted: the Switch support either TRUNKING or VLAN. As
soon as one is enabled, it also means the other is turned off at the
mean time.
Default:
No Trunking or VLAN Group in the device
.
4.2.1 Trunking Group Setting
Entry:
Select “1” from Sub Menu, press “ENTER”
4-port Trunk on Port 1/2/3/4
2-Port Trunk on Port 1/2
SWITCH in 1-VLAN mode
Trunk (1) Disable (2)2-Port (3)4-Port (4)Cancel Setting>>
Purpose:
Assign Trunk group setting option.
16
PLANET NOVASwitch series
Download from Www.Somanuals.com. All Manuals Search And Download.
Default:
No Trunk Group in the device.
Note:
As soon as trunk port enabled, the ports will be grouped as
followings:
2-port Trunk:
1st group: 1, 3, 5, 7, 9, 11, 13, 15, 17, 21, 23
2nd group: 2, 4, 6, 8, 10, 12, 14, 16, 18, 19, 20, 22, 24
4-port Trunk:
1st: 1, 5, 9, 13, 17, 21
2nd: 2, 6, 10, 14, 18, 22
3rd: 3, 7, 11, 15, 19, 23
4th: 4, 8, 12, 16, 20, 24
Once trunk-port enabled, your are free to connect the Switch to any 3rd
party’s standard switch with two links or four links without fears of
network looping. The trunks will two or four times the bandwidth
between the Switch to the connected switch.
After trunk-port enabled, please make the links directly and be sure to
make the connection successfully or the group users may fail to
access the network resource.
Note:
Please make sure the switch that your Smart Switch is going to
connect to is “Trunking” disabled. That is, either the Smart Switch
or any 3rd party switch can turn on the “trunking” at a time.
4.2.2 VLAN Group Setting
Entry:
Select “2” from sub menu, press “ENTER”
PORT 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
VLAN1
VLAN2
VLAN3
VLAN4
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
( 1) Set VLAN( 2) Save/ Exi t ( 3) Exi t >>
17
FNSW-16/2400S User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Purpose:
Set up the VLAN Group
Default:
No VLAN Group in the device (all ports in VLAN1)
Note: Use Toggle to select VLAN group and “SAVE” to make the
setting take effect.
VLAN setting example 1,
Follow the selection to add port 1 to VLAN2.
Ent er Por t # >>
1
Toggl e Gr oup( 1~4) t o add/ r emove ( 5) Updat e VLAN set t i ng >>
2
Toggl e Gr oup( 1~4) t o add/ r emove ( 5) Updat e VLAN set t i ng >>
5
The restult is as below:
PORT 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
VLAN1
VLAN2
VLAN3
VLAN4
X
x
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
( 1) Set VLAN( 2) Save/ Exi t ( 3) Exi t >>
Follow the steps again to add the VLAN groups.
VLAN Setting Example 2
Add port 5 to the four VLANs to maks it server for those VLANs.
( 1) Set VLAN( 2) Save/ Exi t ( 3) Exi t >>
1
Ent er Por t # >>
5
Toggl e Gr oup( 1~4) t o add/ r emove ( 5) Updat e VLAN set t i ng >>
Toggl e Gr oup( 1~4) t o add/ r emove ( 5) Updat e VLAN set t i ng >>
Toggl e Gr oup( 1~4) t o add/ r emove ( 5) Updat e VLAN set t i ng >>
Toggl e Gr oup( 1~4) t o add/ r emove ( 5) Updat e VLAN set t i ng >>
2
3
4
5
With the setting below, the Switch will separate port 1 to port 4 into 4
VLANs, i.e. those ports can not reach each other. However, they can
still access port 5 without problem.
PORT 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
VLAN1
VLAN2
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
18
PLANET NOVASwitch series
Download from Www.Somanuals.com. All Manuals Search And Download.
VLAN3
VLAN4
X
X
X
X
4.3 Port Status
Entry:
Select “2” from < Console Manu>
PORT 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Aut oN
BackP
Pause
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
SWI TCH i n 1- VLAN mode
Any key t o qui t ! !
Purpose:
Display the Port Status group
AutoN for “Auto-Negotiaion”, BackP for “Back Pressure”, half-duplex
flow control. Pause for “Pause frame” stands for full-duplex flow
control.
4.4 Port Setting
Entry:
Select “3” port setting, press “ENTER”
Enter Port Number
Purpose:
Set up the port setting group
Port Setting chart example 1
Set port 1 to works in 100Mbps Full-Duplex mode
Enet r Por t Number ( ( qq) t o qui t ) >>
1
Sel ect ( 1) Por t Mode ( 2) Pause ( 3) Back Pr essur e>>
1
Sel ect ( 1) Aut o_Nego ( 2) 100FDX ( 3) 100HDX ( 4) 10FDX ( 5) 10HDX>>
2
Port Setting chart example 2
19
FNSW-16/2400S User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Enable port 2’s PAUSE frame support
Enet r Por t Number ( ( qq) t o qui t ) >>
2
Sel ect ( 1) Por t Mode ( 2) Pause ( 3) Back Pr essur e>>
2
Sel ect Pause i n FDX ( 1) Enabl e ( 2) Di sabl e>>
1
PAUSE frame is used while the devices that connect to the Switch
runs in Full-duple mode. In full-duplex mode, once the Switch can not
handle the incoming packets, the Switch send out the PAUSE frame
to warn the device hold the transmission. Be noted, the connected
devices should also support the function at the same time or to enable
the capability will not helps in avoid packet loss.
Default: Enabled per port
Port Setting chart example 3
Enable port 3’s Back-pressure.
Enet r Por t Number ( ( qq) t o qui t ) >> 3
Sel ect ( 1) Por t Mode ( 2) Pause ( 3) Back Pr essur e>>3
Sel ect Back Pr essur e i n HDX ( 1) Enabl e ( 2) Di sabl e>>1
When a half-duplex device was not able to handle the amount
of data it was receiving from an end station, it collided with it
(faked a collision by sourcing JAM). Thus all devices on the
shared LAN would have to back-off, and then try to retransmit.
The device could keep on colliding, so the other end station
won’t loss its packets.
Default: Enabled per port
4.5 Factory Setting
Entry:
Select “4” from < Console Manu>
Purpose:
20
PLANET NOVASwitch series
Download from Www.Somanuals.com. All Manuals Search And Download.
Set up the Factory default value, the system will be Auto
Reboot
4.6 Redundant Link Setting
Entry:
Select “5” from < Console Manu>
Redundant Li nk on Por t - 20/ Por t - 19( 19 i s Backup l i nk)
( 1) Enabl e ( 2) Di sabl e >>1
Purpose:
Set up Redundant Link. So the backup line enabled once the
primary line is absent.
4.7 Save Setting
Entry:
Select “6” from < Console Manu>
Purpose:
Set up the Save Setting, save the setting to EEPROM.
21
FNSW-16/2400S User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
This page intentionally left blank!
22
PLANET NOVASwitch series
Download from Www.Somanuals.com. All Manuals Search And Download.
5.OPTIMIZING CONFIGURATION
5.1 Prior to Installation
Before installing the Switch and connecting network devices, it
is important to plan the new network layout. Consider:
·
Dedicated Bandwidth: File servers and other high-traffic
hardware can improve if they have their own direct connection
with dedicated 10 or 100Mbps bandwidth.
·
·
·
Full-Duplex: Determine which devices would benefit from a
Full Duplex connection and check that they support it.
Fast Ethernet: 100Base-TX and 100Base-FX have different
rules for cable and distance. Make sure these are followed.
Auto-Negotiation: Devices with different speeds may be
easily swapped when the other end of the cable is fixed to a port
with auto-negotiation.
·
Crossover Uplink: Another hub can be attached to Switch
using UTP Crossover function.
5.2 Half- and Full-Duplex
The Switch support both Half- and Full-Duplex modes for
10Base-T, 100Base-TX, and 100Base-FX. Half-Duplex mode is
the traditional data transfer mode: one station sends data while
other devices wait for the first to finish.
Full-Duplex is the simultaneous transmission and receiving of
data. It is only possible between two devices with a dedicated
link (e.g., switch-to-switch, switch-to-PC). Both of the devices
must be capable of, and set to, Full-Duplex
The 100Base-FX port set Half- or Full-Duplex mode through
module's DIP-switch. 100Base-TX ports use auto-negotiation to
detect and set the line's operating mode.
23
FNSW-16/2400S User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
5.3 Fast Ethernet
100Base-TX and 100Base-FX are called "Fast Ethernet." This
is because they use the Ethernet CSMA/CD access rules and
data packet structure, but data travels ten times faster
(100Mbps) than traditional 10Mbps Ethernet.
Below is a list of the cable types and connectors that supported
by Switch for 10Base-T, 100Base-TX, and 100Base-FX
networks.
PORT TYPE
100BASE-TX
10BASE-T
CABLES TYPE
CONNECTOR
RJ-45
Cat. 5 UTP only
Cat.3, 4, 5 UTP
RJ-45
Table C: Cables & Connectors Supported by FNSW-2400S
In many cases, 10Base-T LANs can quickly and easily upgrade
to 100Base-TX networks. Also, 100Base-FX will become more
popular due to its longer range. Table lists the maximum Fast
Ethernet connection distances.
MAX. LINK DISTANCE
DTE-DTE¹
COPPER COPPER+FIBER²
FIBER
412m/2,000m4
272m
100m
200m
200m
205m
n/a
261m
309m
216m
1 Class-I Repeater³
1 Class-II Repeater
2 Class-II Repeaters
318m
228m
NOTES: 1) "DTE" is an end-station such as a PC or switch port
2) Copper+Fiber assumes the max. Copper length is used
3) "Repeater" is a standard hub, NOT a Switch.
4) Half-/Full-Duplex. Fiber's distance depends on mode.
Table D: 100Base-TX/FX Topology Rules
24
PLANET NOVASwitch series
Download from Www.Somanuals.com. All Manuals Search And Download.
5.4 Auto-Negotiation
The 100Base-TX ports on the Switch have built-in "Auto-
Negotiation". This technology automatically sets the best
possible bandwidth when a connection is established with
another network device (usually at Power On or Reset). This is
done by detect the mode and speed at the second device is
capable of. The 100Base-TX devices can connect with the
100Base-TX port in either Half- or Full-Duplex mode.
If attached device is:
100Base-TX port will set to:
100Mbps, no auto-negotiation
100Mbps
(100Base-TX, Half-Duplex)
100Mbps, with auto-negotiation
10Mbps, no auto-negotiation
10Mbps, with auto-negotiation
200Mbps
(100Base-TX, Full-Duplex)
10Mbps
(10Base-T, Half-Duplex)
20Mbps
(10Base-T, Full-Duplex)
5.5 MAC Address Table
This 6-byte ID is called the MAC (Media Access Control)
Address. Every Ethernet data packet includes both source and
destination addresses.
The Switch can automatically learn and store up to 2K MAC
addresses. The MAC address table is volatile: it disappears
when the switch is powered off or reset.
Note: When the network needs reconfiguration, we
recommend turning off the power first. After all
nodes have been moved, power on the switch to
rebuild the internal MAC address table.
25
FNSW-16/2400S User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
5.6 Sample Application
The optimal application for the Switch, no matter with the
extension module or not, is as a "big pipe" backbone
interconnecting file servers with bandwidth-hungry workgroups,
departments, and offices.
In the figure, the first FNSW-2400S links to another switch‘s
Uplink (MDI-II) port, some ports connect to 100Mbps
Workstations, and attached to file servers at 200Mbps. This
example highlight the extra distance provided by 100Base-FX
fiber-optic, using the Port #24 of FNSW-2400S with the rear
module installed.
200Mbps
Server Farm
FNSW-2400S
400Mbps
2Km
100Base-FX
100Mbps full duplex
FNSW-1600
20Mbps
10Mbps
FNSW-2400S
FSD-1-020
200Mbps
EH-1602R
20Mbps
10Mbps
Server Farm
EH-3200
10Mbps
100Mbps
DH-1600
Ethernet/Fast Ethernet Hubs
10/100Mbps
Workgroup
10/20Mbps
Workgroups
Figure 3: Sample Application for the Switch with Turnk
26
PLANET NOVASwitch series
Download from Www.Somanuals.com. All Manuals Search And Download.
6.TROUBLESHOOTING
Link LED does not lit after cable is connected to
the port.
SYMPTOM
4 Verify that the other end of the cable is
connected to a device that is powered on and
on-line.
CHECKPOINT
4 For UTP cable connection to another hub,
verify that only one end of the cable is
connected to a “MDI-II” Uplink port.
100Base-TX port Link LED is lit, Collision LED is
blinking, but traffic is irregular.
SYMPTOM
4 Check that the attached device is not set to
dedicated full-duplex. (Some devices use
a physical or software switch to change
duplex modes. Auto-negotiation may not
recognize this type of full-duplex setting.
CHECKPOINT
After setting the DIP-switch of the 100Base-FX
SYMPTOM
module,
the
attached
device
doesn’t
communicate normally with the port.
4 The attached network device MUST be set
CHECKPOINT
to operate in the same duplex mode.
ALWAYS CHECK THAT THE CABLE, LINK DISTANCES,
AND OVERALL NETWORK DIAMETER ARE WITHIN
SPEC. FOR THE NETWORK TYPE.
27
FNSW-16/2400S User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
This page intentionally left blank!
28
PLANET NOVASwitch series
Download from Www.Somanuals.com. All Manuals Search And Download.
7.PRODUCT SPECIFICATIONS
PRODUCT
FNSW-1600S / FNSW-2400S
16/24 10/100Base-TX RJ-45 (MDI-X)
NETWORK PORTS
BUFFER MEMORY
EXTENSION SLOT
MEDIA SUPPORT
4Mb
1 open slot (shared with port 16/24 for optional module)
100Base-TX Cat. 5 UTP, RJ-45
10Base-T Cat. 3, 4, 5 UTP RJ-45
100Base-TX, 200/100/20/10Mbps, Auto-Negotiation
BANDWIDTH
148,800 packets/second per port @ 100Mbps, max.
14,880 packets/second per port @ 10Mbps, max.
FILTER/ FORWARD
RATE
Up to 2K 6-Byte full MAC address entries max.
Self-learning
MAC ADDRESSES
1 for MDI-X / MDI-II selection for port 12/20
SWITCHES
1 for Power On/Off, Module Installed
LEDs
3 per port for 100Mbps, Full-Duplex/ Collision, Act/Link,
Auto-switching. Input voltage: 100~240 VAC,
50 ~ 60Hz
POWER SUPPLY
ENVIRONMENT
Operating Temp: 0 ~ 50°C (32 ~ 122°F)
Storage Temp: -30 ~ 70°C (-22 ~ 158°F)
Humidity 0 ~ 90% non-condensing
430 x 180 x 44 mm (16.9 x 7.1 x 1.73 in.)
FCC Class A, CE
DIMENSIONS
EMISSION
SAFETY
UL, TUV/GS (EN60950)
Table E: Product Specifications
29
FNSW-16/2400S User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
8. RJ-45 PIN ASSIGNMENT
Numbered Ports
(MDI-X port)
Input Receive Data +
Pin
1
Uplink Port (MDI-II port)
Output Transmit Data+
Output Transmit Data-
2
Input Receive Data -
3
Output Transmit Data+ Input Receive Data +
Output Transmit Data- Input Receive Data -
6
4,5,7,8 Not used
Not used
Schematics for both straight and crossover twisted-pair cable are shown
below. (Note that crossover cable is only required if you cascade hubs via the
RJ-45 station ports; i.e. the Uplink port is not used.)
8.1 Straight-Through/Crossover Cable
The pin assignment of the cables both ends should be as below:
Straight-through
Crossover
Hub (MDI-X) Adapter(MDI-II) Hub (MDI-X)
Hub (MDI-X)
Pin 3
Pin 1
Pin 2
Pin 3
Pin 6
Pin 1
Pin 2
Pin 3
Pin 6
Pin 1
Pin 2
Pin 3
Pin 6
Pin 6
Pin 1
Pin 2
6
32
1
32
1
6
6
3
2
1
30
PLANET NOVASwitch series
Download from Www.Somanuals.com. All Manuals Search And Download.
ISO9002
EMFNSWSv1
Download from Www.Somanuals.com. All Manuals Search And Download.
|