IMPORTANT FOR FUTURE REFERENCE
Please complete this information and retain this
manual for the life of the equipment:
Model #: ________________________
Serial #: ________________________
Date Purchased: __________________
Installation and Operation Manual
Covering
Model 65 Series Fryer
with Millivolt Gas Valve
THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE
L20-299 Rev. 0 6/06
Download from Www.Somanuals.com. All Manuals Search And Download.
TABLE OF CONTENTS
INSTALLATION ...................................................................................................................... 1
Checking Your New Appliance............................................................................................................................................. 1
Assembly and Leveling........................................................................................................................................................ 1
Leg/Caster Installation and Leveling.................................................................................................................................... 1
Heat Deflector Installation ................................................................................................................................................... 2
Installation............................................................................................................................................................................ 2
Installation Clearances ......................................................................................................................................................... 2
Gas Connection .................................................................................................................................................................... 2
Quick Disconnect Gas Connection....................................................................................................................................... 3
Fuel Supply Line Leak and Pressure Testing ....................................................................................................................... 3
Ventilation and Fire Safety Systems .................................................................................................................................... 3
Initial Adjustments................................................................................................................................................................. 4
Burner Ignition Systems....................................................................................................................................................... 4
Lighting Instructions ............................................................................................................................................................ 5
Pilot Flame Adjustment........................................................................................................................................................ 5
Main Burner System Adjustment......................................................................................................................................... 6
Initial Cleaning..................................................................................................................................................................... 7
OPERATION ........................................................................................................................... 8
Filling the Tank ...................................................................................................................................................................... 8
Filling the tank with liquid shortening/oil............................................................................................................................ 8
Filling the tank with solid shortening/oil.............................................................................................................................. 8
Operating Instructions........................................................................................................................................................... 8
Appliance Start-Up............................................................................................................................................................... 9
Appliance Shutdown ............................................................................................................................................................ 9
Power Failure ....................................................................................................................................................................... 9
MAINTENANCE AND ADJUSTMENTS ............................................................................... 10
Daily Cleaning.................................................................................................................................................................... 10
Thermostat Calibration Check............................................................................................................................................ 10
Thermostat Calibration....................................................................................................................................................... 11
Weekly Cleaning................................................................................................................................................................... 11
General Cleaning................................................................................................................................................................ 11
Boil Out Procedure............................................................................................................................................................. 11
Ventilation Hood Maintenance........................................................................................................................................... 12
TROUBLESHOOTING.......................................................................................................... 13
Basic Troubleshooting Flow Chart..................................................................................................................................... 13
WIRING DIAGRAM............................................................................................................... 14
L20-299 Rev. 0 6/06
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION/OPERATION
INSTALLATION
Checking Your New Appliance
Your new appliance has been carefully packed into one crate. Every effort has been made to ensure that you it
is delivered to you in perfect condition. As you unpack your new appliance, inspect each of the pieces for
damage. If something is damaged, DO NOT sign the bill of lading. Contact the shipper immediately; the shipper
is only responsible for 15 days after delivery. Check the packing list enclosed with your appliance to ensure that
you have received all the parts to the appliance. If you are missing any parts, contact the dealer from whom the
appliance was purchased. As you unpack the appliance and its accessories be careful to keep the weight of the
appliance evenly distributed.
CAUTION
To prevent equipment damage and/or personal injury, do not tilt the appliance onto any
two of its casters or legs, or pull the appliance by the flue vent.
Locate your warranty and fill in the serial number of the appliance and the date of purchase and write them on
the cover of this manual for future reference. You will find the serial number on the date plate located inside the
door or on the back lower panel
Assembly and Leveling
When you receive your appliance it is completely assembled with the possible exception of the legs (or casters)
and heat deflector.
Leg/Caster Installation and Leveling
This appliance must be installed with legs or casters; it
cannot be curb mounted. Curb mounting will seriously inhibit
this appliances ability to effect proper combustion.
WARNING
This appliance must be installed with the legs or casters provided by the manufacturer.
WARNING
Do not install legs or casters, or perform leveling procedure when unit is in operation or
full of cooking medium. Serious injury could result.
Required tools: 7/16 “ wrench and socket and a large pair of water pump pliers. The legs/casters must be
installed before connecting the appliance to the gas supply. The legs provide the necessary height to meet
sanitation requirements and assure adequate air supply to the combustion system. Use the following procedure.
a.
b.
c.
Lay the appliance on its back, being careful not to damage the flue area by pulling on it. Protect
the outside of the appliance with cardboard or a drop cloth when laying it down.
Attach each leg/caster with the hex head screws and nuts supplied. Each leg/caster requires
four ¼-20 x 5/8” hex head screws and nuts. Insure that all screws are tight.
Mount the screws from the inside of the appliance with the nut on the outside (bottom) of the
appliance. The nuts have lock washers attached to them, therefore it is not necessary to use
lock washers
d.
When all four legs/casters are securely mounted, stand the unit up, being careful not to put too
much weight on any one leg. Adjust the height and level the appliance by adjusting the leveling
devices (B) with water pump pliers. On casters, loosen 2 screws (A) before leveling, then
retighten.
1
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION/OPERATION
Heat Deflector Installation
If the appliance requires a heat deflector, you will find a removable label at the rear top edge of the unit. This
label has instructions for positioning and installation of the heat deflector. Refer to the label and the instructions
below to install the deflector.
a.
b.
Remove the two self-drilling screws from the top, back area of the appliance.
Position the heat deflector so that the angled portion of the deflector is facing toward the front of
appliance. Secure the heat deflector to the back of the unit using the two previously removed
fasteners.
c.
When properly installed the angled section of the heat deflector will extend over the flue
opening to redirect the heat. It SHOULD NOT cover the flue opening. Never allow anything to
block the flue opening; this will cause the appliance to over heat and inhibit proper combustion,
which could produce dangerous gases
Installation
If you have completed the above steps that are applicable to the appliance you purchased, the appliance is now
ready to be installed. Although it may be possible for you to install and set up your new appliance, it is
STRONGLY recommended that you have this done by qualified professionals. A qualified professional will
ensure that the installation is safe and meets local building and fire codes.
WARNING
DO NOT obstruct the flow of combustion, ventilation or air openings around the appliance.
Adequate clearance around the appliance is necessary for servicing and proper burner
operation. Ensure that you meet the minimum clearance requirements specified in this
manual.
Installation Clearances
The clearances shown below are for combustible and non-combustible installations and will allow for safe and
proper operation of your appliance.
Non-
Combustible
Combustible
Construction
Construction
Back
Sides
Floor
6 in. (15 cm)
6 in. (15 cm)
6 in. (15 cm)
0
0
6 in. (15 cm)
In addition to the above clearances there must also be at least 28 in (71.2cm) of aisle space in front of the unit.
Gas Connection
Your appliance will give you peak performance when the gas supply line is of sufficient size to provide
the correct gas flow. The gas line must be installed to meet the local building codes or National Fuel
Gas Code ANS Z223.1 and NFPA 54 (latest editions). In Canada, install the appliance in accordance
with CSA B149.1 or .2 and local codes. Gas line sizing requirements can be determined by a qualified
installation professional, your local gas company or by referring to the National Gas Fuel Code,
Appendix C, Table C-4 (for natural gas) and Table C-16 (for propane). The gas line needs to be large
enough to supply the necessary amount of fuel to all appliances without losing pressure to any
appliance. A properly sized and installed gas line will deliver a minimum supply pressure of 7.0 ± 2.0
inches w.c. (17.4 ± 5 mbar) for natural gas and 12.0 ± 2.0 inches w.c. (29.9 ± 5 mbar) for propane gas
to all appliances connected to the supply line, operating simultaneously at full demand. Each
appliance is equipped to operate on one certain fuel type. The type of fuel with which the appliance is
intended to operate is stamped on the data plate.
2
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION/OPERATION
WARNING
NEVER supply the appliance with a gas other than the one that is indicated on the data
plate. Using the incorrect gas type will cause improper operation and could result in
serious injury or death. If you need to convert the appliance to another type of fuel,
contact the dealer you purchased it from.
NOTICE
NEVER use an adaptor to make a smaller gas supply line fit the appliance connection.
This may not allow proper gas flow for optimum burner operation, resulting in poor
performance and improper operation.
Quick Disconnect Gas Connection
Gas appliances equipped with casters must be installed with connectors that comply with the
Standard for Movable Gas Appliances, ANSI Z21.69 • CSA 6.16 latest edition. This connection should
include a quick disconnect device that complies with the Standard for Quick Disconnect Devices for
Use With Gas Fuel, ANSI Z21.41 • CSA 6.9 latest edition. When installing a quick disconnect you
must also install adequate means for limiting the movement of the appliance without depending on the
connector and quick-disconnect device or its associated piping to limit the movement of the appliance.
The restraining device should be attached to the appliance on the back panel.
Fuel Supply Line Leak and Pressure Testing
The fuel supply system must be tested before the appliance is used. If the fuel line is going to
be tested at a pressure greater than ½ PISG (3.45 kPa), insure that that appliance is
disconnected from the fuel line. If the fuel line is to be tested at a pressure equal to or less than
½ PSIG (3.45 kPa), the appliance can be connected during the test, but the unit’s gas valve
must be shut. Test all gas line connections for leaks with a solution of soap and water when
pressure is applied.
Ventilation and Fire Safety Systems
Your new appliance must have proper ventilation to function safely and properly. Exhaust gas
temperatures can reach as high as 1100 °F (593 °C). Therefore, it is very important to install a fire
safety system. Your ventilation system should be designed to allow for easy cleaning. Frequent
cleaning and proper maintenance of the ventilation system and the appliance will reduce the chances
of fire. The following tables contain a list of reference documents that will provide guidance on
ventilation and fire safety systems. It is not necessarily complete. Additional information can be
obtained from CSA International, 8501 East Pleasant Valley Road, Cleveland, OH, 44131 or visit their
Hoods and Ventilation Systems
National Fuel Gas
TOPIC
UL Document
Code Document
ANSI/NFPA 96
ANSI/NFPA 96
ANSI/NFPA 96
Exhaust Hoods
Power Ventilators
Filter Units
ANSI/UL 70
ANSI/UL 705
ANSI/UL 900
Types of Fire Extinguishers and Detection Equipment
National Fuel Gas
Topic
UL Document
Code Document
ANSI/NFPA 12
ANSI/NFPA 17
ANSI/NFPA 13
ANSI/NFPA 11
ANSI/NFPA 13
ANSI/NFPA 72
ANSI/NFPA 72
CO2 Type Extinguishers
Dry Chemical Type Extinguishers
Water Type Extinguishers
Foam Type Extinguishers
Sprinklers
ANSI/UL 154
ANSI/UL 299
ANSI/UL 626
ANSI/UL 8
ANSI/UL 199
ANSI/UL 268
ANSI/UL 521
Smoke Detectors
Fire Detection Thermostats
3
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION/OPERATION
It is essential that the appliance be operated only when adequate ventilation is provided. Your ventilation hood
should be properly maintained. A qualified installation professional should ensure that the hood is operating
properly in conjunction with the appliance. Inadequate ventilation may not properly evacuate appliance all
emissions. Excessive or unbalanced ventilation may cause drafts, which could interfere with proper operation of
the pilot and burners. Leave at least 18 inches (46 cm) of open space between the flue of the appliance and the
intake of the exhaust hood.
CAUTION
Ensure that your ventilation system does not cause a down draft at the appliance’s flue
opening. A down draft will not allow the appliance to exhaust properly and will cause
overheating, which may cause permanent damage. Damage caused by down drafts will not
be covered by the warranty. NEVER allow anything to obstruct the flow of combustibles or
ventilation exiting the appliance. NEVER place anything on top of the flue area, or block
the flue in any way.
NOTICE
NEVER connect the ventilation blower or hood directly to the flue of this appliance. The
resulting increased flow of air through the combustion system will cause improper
operation, poor temperature recovery, poor ignition and could extinguish the pilot.
Initial Adjustments
After your appliance has been properly installed as described in the installation section of this manual, it will
need to be adjusted to ensure that it will perform as designed. These adjustments must be performed by a
qualified person. To perform these adjustments the following tools will be needed:
• Manometer
• Digital Thermometer (Temperature Probe)
• DC Millivolt Meter
Before you begin filling and adjusting the appliance, perform the
following visual checks:
a.
After the appliance is in its permanent location,
check the levelness. Any additional leveling that
is necessary can be performed as previously
described.
b.
c.
Check the temperature probe and high limit bulb
(in the tank) to ensure that the mounting screws
are tight.
Review the installation portion of this manual and
ensure that all steps have been followed and
executed properly.
Ensure that these
Parts are not loose
Burner Ignition Systems
CAUTION
Before proceeding any further, fill the tank with WATER. Water is used for the installation
adjustments because the temperature will never exceed 212°F (100°C), thereby allowing
plenty of adjustment time. Never let the water level go below the “OIL LEVEL” mark
stamped on the tank.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION/OPERATION
WARNING
During operation there is an open flame inside this appliance. The unit may get hot
enough to set near by materials on fire. Keep the area around the appliance free from
combustibles.
Lighting Instructions
For manual pilots, refer to the following instructions.
WARNING
If pilot extinguishes, wait 5 minutes before attempting to relight the pilot to allow any built
up gas to dissipate.
a.
Open gas supply valves to the appliance.
b.
c.
Turn the thermostat control knob counterclockwise to the OFF position.
Turn the gas valve knob counterclockwise to the PILOT position. Push knob
in and hold a flame to the pilot until the pilot ignites; this may take a little while
the first time you light the pilot because of the air in the lines. Once lit, hold
the knob in for approximately one minute and then release.
d.
If the pilot goes out, wait 5 minutes and repeat step C. If after three tries the
pilot will not remain lit, refer to the operator troubleshooting section of this
manual.
e.
f.
Once a pilot flame has been established, turn the gas valve knob
counterclockwise to the ON position.
Set the thermostat control knob to the desired temperature setting, The main
burners will ignite and be controlled by the thermostat.
Pilot Flame Adjustment
For manual pilots, refer to the following instructions. Perform this procedure once the pilot is lit and
ensure that the thermostat is turned to the OFF position.
NOTE: This procedure requires a DC millivolt meter set to a scale of 0-1000 mV.
Using test leads with sharp probes will help in taking the required readings.
a. Locate the thermopile wires coming from the pilot to the
gas valve.
b. Using the positive (+) test probe, connect the probe to
the top PP terminal with the red wire.
c. Connect the negative (-) test probe to the bottom PP
terminal with the white wire.
d. The output level should be 550mv ± 50mV. If this level
is not correct, remove the cap screw and adjust the
screw in and out to achieve the proper millivolt level.
Replace cap screw.
Note: Allow 3 to 5 minutes between flame adjustments to allow the reading to stabilize.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION/OPERATION
Main Burner System Adjustment
For the main burners to operate the gas supply valve must be open and the thermostat must be turned
on. For models with electric controls, the main power switch must be on. The main burners receive gas
from the main gas supply through the thermostatically controlled valve. When the thermostat is turned up
the gas control valve opens.
The main burners must be adjusted to deliver optimum flame. Refer to the following procedure to adjust the
main burners.
CAUTION
Before proceeding any further, fill the tank with WATER. Water is used for the installation
adjustments because the temperature will never exceed 212°F (100°C), thereby allowing plenty of
adjustment time. Never let the water level go below the “OIL LEVEL” mark stamped on the tank.
a.
Ensure that the main gas valve is shut off, remove the manifold pressure tap plug and
connect an accurate pressure gauge (range of 0-16 “ w.c. in 0.1” increments) or
manometer.
b.
Turn on this and all appliances connected to the gas supply line and light their main
burners. The pressure reading of the installed pressure gauge should not drop from the
required installation pressure. Any loss of pressure indicates inadequate supply line
installation, which will cause poor performance of all appliances during peak usage.
c.
d.
The installed pressure gauge should be the same, ±0.1” w.c, as that marked on the data
plate on the inside door or on the back of the appliance. If the pressure is correct, go to
step e, if it is not, adjust the pressure as outlined in step d.
To adjust the pressure, remove the regulator adjustment screw cap and, with a flat head
screwdriver, adjust the regulator screw until the proper burner pressure is reached. Turning the
screw clockwise will increase the burner pressure. Turning the screw counterclockwise will
decrease the burner pressure.
e.
When the pressure is correct, replace the regulator adjustment screw cover.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION/OPERATION
Initial Cleaning
When your appliance is shipped, many of its parts are covered with a thin coat of shortening/oil for protection.
Before the appliance is ready for cooking it must be cleaned. This will remove the shortening/oil coating and any
foreign matter that may have accumulated during storage and shipment. Refer to the following procedure to
clean the appliance.
a.
b.
Fill the tank with water. Light the pilot, turn the appliance on and set the thermostat to
200°F (93 °C).
Allow the appliance to heat for 15 minutes. Add cleaner to the water, stirring with the cleaning
brush to ensure that the cleaner dissolves thoroughly.
CAUTION
DO NOT leave the appliance unattended during cleaning. Never let the water level go below the
“OIL LEVEL” mark stamped on the tank.
c.
d.
Using the cleaning brush, scrub the inside of the tank to remove the protective coating.
When cleaning is complete turn the appliance off and drain the water into a container suitable
for hot water and dispose of it.
WARNING
Wear protective gloves and clothing when cleaning and draining the appliance and when
disposing of water. The water is extremely hot and can cause severe injuries.
e.
When the tank has cooled, rinse thoroughly with cool water. Continue to rinse the tank
until the cleaner has been completely and thoroughly rinsed from the tank.
f.
Using a clean dry cloth, wipe out all of the water. Be very thorough when removing the
water, as any residual water will cause hot shortening/oil to splatter out of the appliance.
NOTICE
Mild steel tanks must be wiped down/coated thoroughly with shortening/oil to keep the tank
from rusting
7
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION/OPERATION
OPERATION
Filling the Tank
Both liquid and solid shortening/oil can be used in this appliance, but liquid is preferred. If solid
shortening/oil is used it is recommended that you melt the shortening/oil before adding it to the appliance.
You can melt solid shortening/oil in the appliance, but you must be very careful not to scorch the
shortening/oil.
OIL LEVEL LINE
Filling the tank with liquid shortening/oil
To fill the tank with liquid shortening/oil refer to the following procedure.
a.
b.
Ensure that the drain valve is completely closed and that there
is no residual moisture in the tank.
Fill the tank with shortening/oil. You may fill the tank to the
“OIL LEVEL” mark or slightly below this nominal level mark:
the shortening/oil will expand slightly when it heats up, raising
the level slightly.
BURNER TUBES
OIL LEVEL LINE
Filling the tank with solid shortening/oil
To fill the tank with solid shortening/oil refer to the following procedure.
WARNING
NEVER melt blocks of solid shortening/oil on top of the burner
tubes. This will cause a fire and could result in personal injury.
a.
b.
Remove the rack covering the tubes (tube rack).
Cut the solid shortening/oil into cubes no larger than one inch.
ALWAYS pack the shortening/oil below, between, and on top
of the burner tubes. DO NOT leave any large air gaps. Use
care when packing the solid shortening/oil into the tank. DO
NOT bend or break the temperature or high limit sensor
probes. If these are damaged the appliance will not function
properly.
BURNER TUBES
c.
Once the appliance tank is firmly packed with shortening/oil to
the level mark, the shortening/oil must be melted. Melt the
shortening/oil by cycling the main burners on for 4 seconds
and off for 30 seconds repeatedly, using the thermostat knob.
If your appliance has a Melt Cycle option, use this to melt the
shortening/oil automatically.
BURNER TUBES
EXCESSIVE
AIR GAPS
Operating Instructions
To ensure the quality of the food you cook in this appliance, follow the preparation instructions from the
food manufacturer. Using the best shortening/oil makes the best fried foods. The best shortening/oil will
last longer than lower grade shortening/oil and save you money. When not in use, the shortening/oil
should be cooled and covered to prevent contamination.
WARNING
This appliance has been installed using restraining devices to prevent accidental tipping or
movement. DO NOT attempt to move the appliance when it is in use or has hot liquid in it.
Splashing hot liquids can cause severe burns.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION/OPERATION
WARNING
Water and shortening/oil DO NOT mix. Keep liquids away from hot shortening/oil.
Dropping liquid frozen foods into the hot shortening/oil will cause violent boiling.
Appliance Start-Up
WARNING
DO NOT start the appliance without filling the tank with shortening/oil first!
To start up the appliance refer to the following instructions.
a.
b.
Light the pilot as previously described in this manual
Turn the temperature control knob (thermostat) to the desired temperature setting. This
knob is located behind the front doors or on the front control panel.
c.
The main burners will light and raise the shortening/oil temperature to the desired setting.
Appliance Shutdown
There are two shutdown modes of appliance operation: STANDBY and COMPLETE. The standby mode
removes the ability of the appliances main burners to operate. Complete shutdown turns off the gas
supply to the appliance.
STANDBY
Turn the thermostat to the OFF position. Turn the gas valve knob clockwise to
the PILOT position. The cooker is now in Standby and can remain this way for
only brief periods of time. NEVER leave the appliance in standby mode for
prolonged periods or overnight.
COMPLETE
Turn the thermostat to the OFF position. To return the gas valve knob to the
OFF position, the knob must be depressed slightly to disengage its stop tab,
then rotated clockwise. The appliance is now completely shut down and can be
cleaned and filtered if desired.
Power Failure
CAUTION
DO NOT attempt to operate this appliance during a power outage.
Wait five minutes after the power is restored before attempting to restart the appliance. This will allow time for
any gas that may have accumulated in the burner or tubes to dissipate. To restart the appliance, follow the
appliance start up procedure in this manual.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
CLEANING AND MAINTENANCE
MAINTENANCE AND ADJUSTMENTS
Daily Cleaning
Your appliance should be cleaned every day to maintain peak performance, proper sanitation and appearance.
Perform the following procedures daily.
a.
b.
Wipe up any shortening/oil that spills onto the exterior of the appliance. This should be done with
a clean soft cloth while the shortening/oil is still warm.
Use warm water with a mild detergent to clean surfaces. Be careful not to get water into the
shortening/oil and be sure to completely remove any detergent from the fry tank. Use a non-
abrasive scouring powder or pad to clean stains if necessary.
NOTICE
Maintenance and repairs should be performed by qualified personnel. If you are
unsure, contact the factory, factory representative to locate the nearest qualified
Service Company.
Thermostat Calibration Check
NOTICE
Thermostat calibration requires that the temperature of the appliance be raised above
boiling. If you have water in the tank you will need to drain it, dry it and fill it with
shortening/oil. Follow the filling instructions in this manual.
To check the calibration of your appliance, refer to the following procedure.
a.
b.
Remove the tube rack from the tank.
Place the tip of a digital thermometer probe in the shortening/oil approximately one inch
above the temperature sensor.
c.
d.
Light the pilot as described in this manual, set the thermostat to 325°F (163 °C) and allow
the shortening/oil to come up to temperature. Watch the thermometer closely as the
temperature rises.
If the shortening/oil temperature reaches 350°F (167 °C) and the burners do not turn off,
turn the thermostat down. Keep lowering the thermostat setting until the burners go out.
CAUTION
If the burners do not shut off at the LOWEST thermostat setting, the thermostat may be
defective. Contact your local service company.
e.
Let the appliance cycle 4 to 6 times before checking the temperature. Compare the
thermometer temperature against the thermostat setting. If the values are more than 5°F
(3 °C) apart, calibrate the thermostat using procedure in this manual.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
CLEANING AND MAINTENANCE
Thermostat Calibration
For Millivolt Thermostats refer to the following procedure.
a.
Remove the tube rack from the tank and place the tip of a digital thermometer in the
shortening/oil approximately one inch above the temperature sensor.
Light the pilot as described in this manual, set the thermostat to 325°F (163 °C) and allow the
shortening/oil to come up to temperature; let the appliance cycle 4-6 times to insure that the
shortening/oil temperature has stabilized. Compare the thermostat setting of 325°F (163 °C) to
the digital thermometer reading.
b.
c.
Remove the thermostat dial by pulling the knob straight out. DO NOT rotate the dial.
Holding the outside of the shaft so that it does not move, scrape away the sealing compound in
the center of the shaft with a small flat blade screwdriver.
d.
Turn the adjustment screw clockwise to lower the thermostat’s temperature setting or counter-
clockwise to raise it.
NOTE
One-quarter turn of the adjustment screw changes the temperature setting
approximately 24°F (13 °C).
e.
f.
Turn the adjustment screw until the burners come on at 325°F (163 °F).
Replace the knob and allow the appliance to cycle 4 to 6 times. Check the temperature of the
digital thermometer against the thermostat dial setting; if there is greater than a 5°F
(3 °C) difference, repeat the calibration procedure.
Weekly Cleaning
General Cleaning
The appliance should be thoroughly cleaned AT LEAST once a week. This should include a thorough wipe down
of the entire appliance with a rag and mild detergent.
WARNING
The power supply must be disconnected before cleaning and servicing this appliance!
WARNING
NEVER spray cleaner into the main burners or pilot. This could act as a magnet for dust and
other debris, causing it to accumulate and inhibit the proper operation of your appliance.
Boil Out Procedure
The appliance should be boiled out AT LEAST once a week to remove food debris and shortening/oil build up.
You will need a container large enough to hold 1 ½ times the shortening/oil in the tank. Refer to the following
procedure for weekly boil out.
WARNING
Completely shut the appliance down when the shortening/oil is being drained and
replaced with water. This will prevent the main burners from coming on during the
draining and filling procedure.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
CLEANING AND MAINTENANCE
WARNING
At operating temperatures, the shortening/oil in the appliance is VERY HOT and can cause
severe burns. Do not let the hot shortening/oil touch your skin or clothing. ALWAYS wear
insulated, oil proof gloves, protective clothing and eyewear when working on a hot
appliance.
a.
b.
Drain the shortening/oil from the appliance and discard or save for reuse. Remove the tube rack
Close the drain valve and fill the tank with warm water and non-caustic detergent
Restart the appliance as described in this manual and set the thermostat to 200°F (93 °C). Bring
the water to a slow boil. DO NOT allow the water to boil excessively as this will cause excessive
foaming and boil over.
c.
Allow the appliance to soak for 20 minutes to soften shortening/oil deposits. Use the cleaning
brush to scrub and remove any residue from the tank, tubes and side walls.
d.
e.
f.
When finished drain the water and wipe the tank dry with a soft clean cloth.
Ensure that the drain valve is closed and replace the tube rack.
You may now refill the tank with shortening/oil per the filling instructions in this manual.
Ventilation Hood Maintenance
Proper ventilation hood operation is very important for the correct operation of this appliance and the safety of
personnel. The ventilation hood should be inspected at the time of installation of this appliance to insure that it
will operate properly in conjunction with the appliance. A regular schedule of examination, in accordance with
ANSI/NFPA 96 latest edition and/or applicable local codes, must be followed.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
TROUBLESHOOTING
TROUBLESHOOTING
Basic Troubleshooting Flow Chart
Refer to this section to correct common problems that may be encountered during the course of normal
operation. If applicable, a schematic is provided on the inside door.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
WIRING DIAGRAM
WIRING DIAGRAM
14
Download from Www.Somanuals.com. All Manuals Search And Download.
THIS PAGE LEFT INTENTIONALLY BLANK
15
Download from Www.Somanuals.com. All Manuals Search And Download.
THIS PAGE LEFT INTENTIONALLY BLANK
16
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation and Operation Manual
Covering
Model 65 Series Fryer
with Millivolt Gas Valve
THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE
L20-299 Rev 0 06/06