Pioneer Stereo Receiver PRV LX1 User Manual

PRV-LX1 RS-422A Protocol  
1.0 Foreword  
The PRV-LX1 can be controlled externally using RS-422A commands. Control is applied through the  
REMOTE IN and REMOTE OUT D-Sub 9 connector on the rear panel. Set the RS-422A REMOTE  
controls through the main menu. Press the Function button on the PRV-LX1’s front panel to access the  
menu. Control Settings are accessed through the Setup menu.  
The REMOTE IN connector is used when controlling this unit with an external device. The REMOTE  
OUT connector is used for external control with this unit.  
Note: This document is valid for PRV-LX1 System Version 3.01/1.04 or later/  
Page 2 of 18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
PRV-LX1 RS-422A Protocol  
2.0 Communication Signal  
The PRV-LX1 conforms to EIA RS-422A and includes a full duplex communication channel. The transfer  
speed is 38.4kb per second.  
Data Format:  
Start Bit:  
Data:  
1 bit  
8 bits  
Parity (ODD): 1 bit  
Stop Bit: 1 bit  
3.0 Cabling  
Pin  
1
Master  
Ground  
Slave  
Ground  
TX-  
2
RX-  
TX+  
3
RX+  
4
Xmit Common Rcv Common  
Spare Spare  
Rcv Common Xmit Common  
5
6
7
RX+  
TX+  
8
TX-  
RX-  
9
Ground  
Ground  
Page 3 of 18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
PRV-LX1 RS-422A Protocol  
4.0 Command Block Format  
The controlling device and the PRV-LX1 communicate through the interchange of command blocks. The  
bytes in each command block are assigned as follows:  
Data  
Count  
CMD-1  
(MSD)  
Data-15  
(MAX)  
CMD-2  
1 Byte  
Data-1  
1 Byte  
Checksum  
1 Byte  
(LSD)  
1 Byte  
1 Byte  
CMD-1/DATA COUNT CMD-1 is the upper 4 bits, DATA COUNT is the lower 4 bits  
CMD-2  
DATA-1 up to DATA-N, where n is the value in data count  
CHECKSUM  
CMD-1  
Indicates the function and direction of the command:  
0 System Control (Controller -> PRV-LX1)  
1 Return for 0, 2, or 4 of cmd-1 (PRV-LX1-> Controller)  
2 Transport Control (Controller -> PRV-LX1)  
4 Preset/Select Control (Controller -> PRV-LX1)  
6 Sense Request (Controller -> PRV-LX1)  
7 Sense Returned (PRV-LX1-> Controller)  
E PRV-LX1 Original Command (Controller -> PRV-LX1)  
F PRV-LX1 Original Return (PRV-LX1->Controller)  
DATA COUNT  
Indicates the number of bytes (maximum 15) inserted between CMD-2 and CHECKSUM  
CMD-2  
Designates the command  
(refer to the Command Table for definitions)  
DATA-1 to DATA-N  
Data that corresponds to those indicated by the command  
(refer to the Command Table for data formats)  
CHECKSUM  
Lower eight bits of the sum of the bytes in the command block  
Communications Protocol  
The controlling device initiates the communication. PRV-LX1 returns a response within 9 milliseconds.  
The response may be:  
NAK + Error Data  
COMMAND + Data  
ACK  
: undefined command or communications error  
: received a command that requests data  
: received a command that requests no data  
Page 4 of 18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
PRV-LX1 RS-422A Protocol  
The controller must ensure that no more than a 10 msec lapse occurs between bytes in a command  
block.  
The controller must immediately stop sending data when it receives a NAK + Error Data message. The  
unit must wait at least 10 msec before resending the command.  
The controller should wait at least 10msec to receive a response from the PRV-LX1. The unit should not  
send another command during this time.  
When the controller does not receive a response from the PRV-LX1 within the 10 msec timeout, it  
assumes that communication has ceased and sends the command again.  
Error descriptions are listed in this manual under the section entitle Command Formats  
If the PRV-LX1 detects a communication error, it sends a NAK and an error code to the controller.  
Page 5 of 18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PRV-LX1 RS-422A Protocol  
5.0 Command Table  
Code  
Command  
Response  
Device Type  
ACK  
00 11  
Device Type Request  
Stop  
12 11 xx xx  
10.01  
20 00  
20 01  
Play  
10 01  
ACK  
20 02  
Rec(ord)  
10 01  
ACK  
20 04  
Standby OFF  
Standby ON  
Eject  
10 01  
ACK  
20 05  
10 01  
ACK  
20 0F  
10 01  
ACK  
20 10  
Fast Forward  
Rewind  
10 01  
ACK  
20 20  
10 01  
ACK  
21 11 xx  
22 11 xx yy  
21 12 xx  
22 12 xx yy  
21 13 xx  
22 13 xx yy  
21 21 xx  
22 21 xx yy  
21 22 xx  
22 22 xx yy  
21 23 xx  
22 23 xx yy  
20 30  
Jog Forward  
10 01  
ACK  
Var Forward  
10 01  
10 01  
10 01  
10 01  
10 01  
ACK  
ACK  
ACK  
ACK  
ACK  
Shuttle Forward  
Jog Reverse  
Var Reverse  
Shuttle Reverse  
Pre-Roll  
10 01  
ACK  
ACK  
ACK  
ACK  
ACK  
ACK  
24 31  
Cue Up With Data  
In Data Preset  
10 01  
44 14  
10 01  
44 15  
Out Data Preset  
Edit Preset  
10 01  
4x 30  
10 01  
44 31  
Preroll Time Preset  
Timer Mode Sense  
TC Gen Data Sense  
Current Time Sense  
Status Sense  
10 01  
60 36  
71 36  
Timer Mode Status  
Gen TC Data  
LTC Time Data  
Status Data  
ACK  
61 0A 01  
61 0C 01  
61 20 xx  
E3 51 11 nn  
E2 51 21 n  
E1 51 22  
E1 51 81  
E1 51 82  
E3 51 71 nn  
E3 51 72 nn  
E5 51 73 fsmh  
E5 51 74 fsmh  
E1 51 75  
E1 51 83  
E1 51 8F  
74 08  
74 04  
7x 20 xx  
10 01  
Title Search  
Chapter Search  
Chapter Mark  
10 01  
ACK  
10 01  
ACK  
Title Number Sense  
Chapter Number Sense  
Title Delete  
E3 51 91 nn  
E2 92 n  
10 01  
Title Number Data  
Chapter Number Data  
ACK  
Trimming Title Preset  
Trimming In Preset  
Trimming Out Preset  
Trimming  
10 01  
ACK  
10 01  
ACK  
10 01  
ACK  
10 01  
ACK  
HDD Capa Sense  
Mode Sense  
E3 51 93 nn  
E2 51 9F xx  
HDD Capacity(GB)  
Mode Data  
Page 6 of 18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
PRV-LX1 RS-422A Protocol  
6.0 Command Formats  
00 11 Device Type Request  
PRV-LX1 Responds with a 12 11 Device Type Message containing 2 bytes of data  
TV System  
NTSC  
DATA 1  
F0  
DATA2  
51  
PAL  
F1  
51  
10 01 ACK  
PRV-LX1 sends this data when it receives a command from a Controller  
11 12 NAK  
When a communication error is detected, the PRV-LX1 sends this command with a “1” in the  
following position indicating the appropriate error condition.  
7
6
5
4
3
2
1
0
Framing  
Error  
Overrun  
Error  
Checksum  
Error  
Undefined  
Command  
Time Out  
Parity Error  
X
X
20 00 Stop  
PRV-LX1 stops when Playing or Recording  
If Stop is sent during a Time Shift PLAY recording, the unit continues recording and returns to the  
scene that the PRV-LX1 is recording.  
20 01 Play  
Starts Playing Title 1 of the selected drive. If the Time Shift PLAY setting is enabled when this  
command is sent to the recording HDD, the PRV-LX1 attempts to Time Shift PLAY the title being  
recorded.  
* During Time Shift PLAY, Status Data is Play not Rec  
20 02 Record  
PRV-LX1 begins recording on the selected Drive(s) and/or to the HDD from a Stop condition.  
20 04 Standby OFF  
If the unit receives this command when stopped, the unit changes to Standby Off.  
20 05 Standby ON  
If the unit receives this command when in Standby Off, it toggles to Standby On.  
20 0F Eject  
Send this command to eject a disc from DVD1 or DVD2 when each drive is stopped. If [Eject  
Setting] is set to Finalize&Eject, the disc is finalized before the tray opens.  
20 10 Fast Forward  
During playback, this command executes 192x speed Scan Forward through to the end of the title  
then pauses the playback. In Time Shift PLAY mode, the command executes 192x speed Scan  
Forward then transfers to Play when it nears the recording scene. (1 – 6 minutes).  
Page 7 of 18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
PRV-LX1 RS-422A Protocol  
20 20 Rewind  
During playback or Time Shift PLAY, this command executes 192x speed Scan Reverse then  
pauses playback at the beginning of the title.  
21 11 xx  
Jog Forward  
22 11 xx yy Jog Forward  
21 12 xx  
Variable Forward  
22 12 xx yy Variable Forward  
21 13 xx  
22 13 xx yy Shuttle Forward  
21 21 xx Jog Reverse  
22 21 xx yy Jog Reverse  
Shuttle Forward  
21 22 xx  
Variable Reverse  
22 22 xx yy Variable Reverse  
21 23 xx  
22 23 xx yy Shuttle Reverse  
During Play, Time Shift PLAY the playing speed will vary according to the speed indicated in  
Shuttle Reverse  
DATA-1(xx). When indicating “0” to DATA-1(xx) while recording, PRV-LX1 pauses recording.  
PRV-LX1 ignores the “yy”.  
DATA-1(xx)  
00  
Speed  
Still (Pause)  
1/90 Slow  
1/30 Slow  
1/16 Slow  
1/8 Slow  
01 to 16  
17 to 25  
26 to 35  
36 to 44  
44 to 54  
55 to 63  
64  
1/4 Slow  
1/2 Slow  
1X Play  
65 to 88  
89 to 98  
99 to108  
109 to 117  
118 to 127  
128 to 255  
6X Scan  
12X Scan  
24X Scan  
48X Scan  
96X Scan  
192X Scan  
20 30 Preroll  
Search to a particular position. Calculate the position value by subtracting the preroll time (set by  
the command 44.31 Preroll Time Preset) from the value stored in the command 44.14 In DATA  
Preset.  
Page 8 of 18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PRV-LX1 RS-422A Protocol  
24 31 Cue Up With Data  
Cues the PRV-LX1 to the indicated time code and pauses.  
DATA – 1  
10  
DATA – 2  
10  
DATA – 3  
10  
DATA – 4  
1
1
1
10  
1
Frames  
Frame  
Seconds Second Minutes  
Minute  
Hours  
Hour  
MSD  
LSD  
MSD LSD MSD  
LSD  
MSD  
LSD  
44 14 In Data Preset  
Preset the value from DATA-1 to DATA-4 to the memory. Data format is same as the format of  
”24:31 Cue Up With Data” command. Using the ”44:31 Preroll” command, search to the position  
that is the value of Preroll Time subtracted from In Data.  
44 15 Out Data Preset  
The PRV-LX1 sends back an ACK; however, the command data is ignored.  
44 30 Edit Preset  
The PRV-LX1 sends back an ACK; however, the command data is ignored.  
44 31 Preroll Time Preset  
Preset the value from DATA-1 to DATA-4 to the memory. Data format is same as the format of  
”24:31 Cue Up With Data” command. Using the ”44:31 Preroll” command, search to the position  
that is the value of the Preroll Time subtracted from In Data.  
60 36 Timer Mode Sense  
The unit returns the “71:36:00” Time Mode Status = TIME CODE  
61 0A 01 Time Code Generator Sense (Gen TC)  
The unit returns “74:08:00:00:00:00” Gen Time Data = 0.  
61 0C 01 Current Time Sense (LTC TIME)  
The unit returns current time code of Recording or Playing title with “74:04 LTC Time Data”. While  
recording in Time Shift PLAY, the playing title’s current time code is returned. Data format is the  
same as the ”24:31 Cue Up With Data” command.  
61 20 Status Sense  
When the PRV-LX1 receives a 61 20 Status Sense command, it returns a 7X 20 Status Data  
response. The starting byte number and number of bytes requested are encoded in DATA-1,  
with starting register in the high nibble (bits 7-4) and the requested byte count in the low nibble  
(bits 3-0).  
Data – 1  
Start Data Number  
MSD  
Data Size  
LSD  
MSD (Bit 7~ 4) Specify what data from “7X:20 Status Data” shall be returned.  
LSD (Bit 3~0) Specify the data number (in Bytes) that shall be returned by the ”7X:20 Status  
Data” command.  
Page 9 of 18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PRV-LX1 RS-422A Protocol  
7X 20 Status Data  
Return all or part of the following data that corresponds to the “61:20 Status Sense” command  
Data  
#
MSB  
Bit – 7  
LSB  
Bit – 0  
Bit – 6  
Bit – 5  
Bit – 4  
Bit – 3  
Bit – 2  
Bit – 1  
0
1
UnThread  
Stop  
Local  
Play  
Standby  
Eject  
Jog  
REW  
VAR  
FF  
Rec  
Still  
Servo  
Lock  
Tape  
Dir  
2
Shuttle  
Cue Up  
3
4
Preroll  
UNTREAD: bit set when the selected drive is open  
LOCAL: bit set when [Operation/Control Setting/Control] is set to Local  
(remote command is not available unless set to Remote)  
STANDBY: bit set in StandbyON mode - also set under Rec and Play  
STOP: bit set in Stop mode  
EJECT: bit set when the selected drive is unloading  
REW: bit set in Full Rewind mode  
FF: bit set in Full Forward mode  
REC: bit set when recording - with TimeShift Play mode turned on while recording, this bit is  
cleared  
PLAY: bit set in Rec or Play  
SERVO LOCK: bit set in Rec or Play  
SHUTTLE: bit set in Shuttle mode  
JOG: bit set in Jog mode  
VAR: bit set in Var mode  
TAPE DIR: bit set in Reverse Play  
STILL: bit set in Record–Pause or Play–Pause  
CUE UP: when the PRV-LX receives a ”20:30 Preroll” or “24:31 Cue Up With Data” command,  
this bit is set after searching is complete and the unit switches to Pause  
(bit is cleared when playing point moves beyond the search point)  
PREROLL: bit set when a “20:30 Preroll” or “24:31 Cue Up With Data” command is received  
(kept till searching is completed)  
E3 51 11 Title Search (PRV-LX1 original command)  
The command searches to a recorded title number  
Values are 1-255 (0x01 0x00 – 0x55 0x02)  
DATA – 2  
DATA – 3  
10  
1
always  
100  
Titles  
Title  
0
Titles  
MSD  
LSD  
MSD  
LSD  
Execute title search to the title number given by DATA-2 and DATA-3. When Time Shift PLAY is  
enabled when recording, if the search title number is same as the title number being recorded,  
Time Shift PLAY executes. However, if the search title number is smaller than Title number being  
recorded, another title plays while recording.  
Page 10 of 18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PRV-LX1 RS-422A Protocol  
E2 51 21 Chapter Search (PRV-LX1 original command)  
The command searches to a recorded chapter number  
Values are 1-99 (0x01 – 0x99)  
DATA – 2  
10  
1
Chapters Chapter  
MSD LSD  
Chapter number is given by DATA-2. Available chapter numbers are from 1 to 99.  
E1 51 22 Chapter Mark (PRV-LX1 original command)  
This command inserts a chapter mark in the Title being recorded.  
E1 51 81 Title Number Sense (PRV-LX1 original command)  
The command returns the total number of titles in the selected project when playback is stopped  
and returns the recording title number when recording. When a title is playing or in TimeShift  
PLAY, the unit returns the playing title number. “E3 51 91 n n Title Number Data”, where nn is the  
title number.  
E3 51 91 Title Number Data (PRV-LX1 original command)  
This command corresponds with the “E1:51:81 Title Number Sense” command. The unit returns  
the total number of titles in the selected project when playback is stopped and returns to the  
recording title number when recording. When a title is playing or in TimeShift PLAY, the unit  
returns the playing title number. Data format is the same as the “E3:51:11 Title Search”  
command.  
E1 51 82 Chapter Number Sense (PRV-LX1 original command)  
This command returns current chapter number, “E3 51 92 nn Chapter Number Data”, where nn is  
the chapter number. When recording, the unit returns the recording chapter number executed by  
the ”E3:51:92 Chapter Number Data” command.  
Returns the playing chapter number during playback or in TimeShift PLAY.  
E3 51 92 Chapter Number Data (PRV-LX1 original command)  
This command corresponds with the “E1:51:82 Chapter Number Sense” command. The unit  
returns the recording chapter number when recording. When a chapter is playing or in TimeShift  
PLAY, the unit returns the playing chapter number. Data format is the same as the “E2:51:21  
Chapter Search” command.  
E3 51 71 Title Delete (PRV-LX1 original command)  
The command deletes the recorded title number.  
Values are 1-255 (0x01 0x00 – 0x55 0x02)  
When a stopped unit receives this command, the title specified by Data–2 and Data–3 is deleted.  
With the ”E1:51:8F Mode Sense” command, it is possible to know if the deletion is complete.  
Issuing the ”E1:51:81 Title Number Sense” command before and after the deletion, confirms that  
the number of titles in the selected project has been reduced. If the number of titles has not been  
reduced then the title deletion has failed so error handling should be executed. Data format is the  
same as the “E3:51:11 Title Search” command.  
Page 11 of 18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PRV-LX1 RS-422A Protocol  
E3 51 72 Trimming Title Preset (PRV-LX1 original command)  
The command presets the trimming title number.  
Values are 1-255 (0x01 0x00 – 0x55 0x02)  
Trimming title number executed by ”E1:51:75 Trimming” command is specified by DATA-2,  
DATA-3, and the title number preset in the memory. Data format is the same as the “E3:51:11  
Title Search” command.  
E5 51 73 Trimming In Preset (PRV-LX1 original command)  
The command presets the trimming In Point. When the unit is stopped, the trimming IN point,  
executed by “E1:51:75 Trimming”, is specified by DATA-2 – DATA-5, and the preset point in the  
memory. Data format is the same as the “24:31 Cue Up With Data” command.  
E5 51 74 Trimming Out Preset (PRV-LX1 original command)  
The command presets the trimming Out Point. When the unit is stopped, the trimming OUT point,  
executed by “E1:51:75 Trimming”, is specified by DATA-2 – DATA-5, and the preset point in the  
memory. Data format is the same as the “24:31 Cue Up With Data” command.  
E1 51 75 Trimming (PRV-LX1 original command)  
This command trims the current title by creating a new title. When the unit is stopped, the title  
specified by ”E3:51:72 Trimming Title Preset” is trimmed from the IN point (specified by ”E5:51:73  
Trimming In Preset”) to the OUT point (specified by ”E5:51:74 Trimming Out Preset”) then made  
into another title. With the ”E1:51:8F Mode Sense” command, it is possible to know if the trimming  
is finished. Issuing ”E1:51:81 Title Number Sense” before and after the trimming confirms that the  
number of titles in the selected project have increased after the trimming. If the number of titles  
has not increased, the trimming has failed so error handling should be executed.  
E1 51 83 HDD Capa Sense  
This command returns remaining capacity of the internal HDD, E3 51 93 n n, HDD Capa(GB)  
where nn is the capacity.  
Ex: 102GB (0x02, 0x01)  
E3 51 93 HDD Capa(GB)  
When the unit receives the ”E1:51:83 HDD Capa Sense” command, the remaining capacity of the  
internal HDD is returned. The remaining capacity is specified in Gbytes by DATA-2 and DATA-3.  
DATA – 2  
DATA – 3  
10  
1
always  
100  
GBs  
GBse  
0
GBs  
MSD  
LSD  
MSD  
LSD  
E1 51 8F Mode Sense  
This command returns Mode Data E2 51 9F XX where XX is the code.  
Ex: 01l:Recording, FF:RecError, 71:Title Delete, 75:Trimming  
Page 12 of 18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PRV-LX1 RS-422A Protocol  
E2 51 9F Mode Data  
When the unit receives the ”E1:51:8F Mode Sense” command, the current status of the unit is  
reported as the value of DATA-2.  
DATA – 2 Status of the PRV-LX1  
01  
FF  
71  
75  
During recording and Time Shift PLAY in recording mode  
Rec error  
Executing title delete  
Executing trimming  
Page 13 of 18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PRV-LX1 RS-422A Protocol  
7.0 Procedure for Issuing Command  
<Example 1>  
< Example 1> is an example of playing Title 2, from the scene10minutes to 20minutes  
“Drive Select” and “Selecting the project” are not possible to be remotely controlled.  
It is possible to get total title number of current project by "E1 51 81 Title Number Sense" command in  
Stop condition.  
Total time of the title cannot be acquired directly by a remote command. However, when a title is played  
by remote commands (e.g. "20 10 Fast Forward"), the title is Paused at the end of the title.  
To calculate the total time of the title, use the "61 0C 01 Current Time Sense" command when PAUSE is  
returned by the "61 20 Status Sense " command.  
Page 14 of 18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
PRV-LX1 RS-422A Protocol  
START  
<Figure 2>  
2002  
Rec  
6120  
StatusSense  
Rec ?  
N
E15181  
Title NumberSense  
Title = 3  
E351110200  
Title Search  
6120  
StatusSense  
Play (not R ec) ?  
N
Play Control  
2002  
Stop  
Wait1sec  
6120  
StatusSense  
Rec ?  
N
END  
<Figure 2> is an example of playing Title 2 while recording Title 3 to HDD.  
On HDD Rec, it is possible to play a title other than the title being recorded when the Time Shift PLAY  
setting is set to Enable.  
“20:02 Stop” command stops Play in Time Shift PLAY condition during recording, and stops Recording in  
Rec condition.  
The unit cannot start recording while in Playback mode. It also cannot stop recording directly during  
TimeShift PLAY. Stop TimeShift PLAY first to stop recording.  
Page 15 of 18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PRV-LX1 RS-422A Protocol  
8.0 Product-Specific Notes  
8.1 Recording Delay  
There is a short delay of approximately 29+/-2 frames between when the PRV-LX1 is issued a record  
command and the command is executed.  
This delay is a result of the following:  
Requires 12 frames for encoding system setup  
Execution of the command may take +2 frames  
Execution of the command may take–2 frames  
Record default offset for the LX1 is 17 frames  
The above delay shows the calculation of a maximum +29 frames +/- 2 frames delay.  
Pioneer Electronics suggest that PRV-LX1 users pad these frame times to the head/tail of the selected  
I/O points to ensure that an entire video sequence is recorded.  
Page 16 of 18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
PRV-LX1 RS-422A Protocol  
8.2 Playback Delay  
When the PRV-LX1 is issued a play command, it experiences up to a +2 frames delay in the execution of  
the command. The decoding system requires 2 frames to accomplish setup.  
8.3 PRV-LX1 as Recording Device  
When issuing a “pause” command while recording, the PRV-LX1 continues recording within the same  
title/clip, maintaining continuous time-code.  
* To issue a “pause” command the user must issue a “shuttle 0” command. This pauses the  
recording to insert a chapter mark at the closest GOP of encoded video then recording  
continues. The [Auto Chapter] setting should be set to manual.  
* Issuing a “stop” command closes the recorded title/clip as defined by the DVD spec. All  
subsequent recordings via serial control start with a new title/clip and the LX1 begins  
generating new time-code within that title/clip.  
8.4 PRV-LX1 as the Source Device  
When the PRV-LX1 is the source device being controlled via serial control with an NLE or edit control  
device, the following limitation applies.  
When an external control device is controlling the LX1 and a “search and play” command is sent via  
serial control, the PRV-LX1 reports back frame numbers every 50ms. The PRV-LX1 cannot return  
the precise time-code. The unit may return the same value as requested earlier or may skip the  
frame while Recording or Playing.  
* Manually record without using serial control when the recorder is to be used as a source. Or,  
if the external control device offers the ability to change the time-code query speeds, change  
the speed to 50ms to match the PRV-LX1.  
Page 17 of 18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
PRV-LX1 RS-422A Protocol  
9.0 Appendix  
Command Matrix by System Version  
Commands  
2.04/1.03  
2.51/1.03  
3.00/1.04  
00 11 Device Type  
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
20.00 Stop  
20.01 Play  
20.02 Rec(ord)  
20.04 Standby OFF  
20.05 Standby ON  
20.0F Eject  
X
X
X
X
X
X
20.10 Fast Forward  
20.20 Rewind  
20.30 Preroll  
21.11 xx Jog Forward  
21.12 xx Var Forward  
21.13 xx Shuttle Forward  
21.21 xx Jog Reverse  
21.22 xx Var Reverse  
21.23 xx Shuttle Reverse  
22.11 xx yy Jog Forward  
22.12 xx yy Var Forward  
22.13 xx yy Shuttle Forward  
22.21 xx yy Jog Reverse  
22.22 xx yy Var Reverse  
22.23 xx yy Shuttle Reverse  
24.31 Cue Up With Data  
44.14 In Preset  
X
X
44.15 Out Preset  
44 31 Preroll Time Preset  
4x.30 Edit Preset  
60 36 Timer Mode Sense  
61 0A 01 Gen Data Sense  
61 0C 01 Current Time Sense  
61 20 xx Status Sense  
E1 51 22 Chapter Mark  
E1 51 75 Trimming  
X
X
X
X
X
X
X
X
E1 51 81 Title Number Sense  
E1 51 82 Chapter Number Sense  
E1 51 83 HDD Capa Sense  
E1 51 8F Mode Sense  
E2 51 21 n Chapter Search  
E3 51 11 nn Title Search  
E3 51 71 nn Title Delete  
E3 51 72 nn Trimming Title Preset  
E5 51 73 fsmh Trimming In Preset  
E5 51 74 fsmh Trimming Out Preset  
*System Update 3.00/1.04 expected release in Calendar-Year 2005, Quarter 1  
Page 18 of 18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
PRV-LX1 RS-422A Protocol Manual  
Pioneer Electronics (USA) Inc.  
Industrial Solutions Business (ISB)  
2265 East 220th Street  
Long Beach, CA 90810  
(310) 952 – 2000  
Published by Pioneer Electronics  
All rights reserved  
Copyright © 2004 Pioneer Corporation  
Printed in the USA [PRV-LX1_422Protocol]  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Pelco Computer Keyboard KBD9000 User Manual
Philips Battery Charger SCM4480 27 User Manual
Philips Car Satellite TV System 40PFL9904H User Manual
Philips Digital Photo Frame SPF2017 User Manual
Planet Technology Network Card WL U356 User Manual
Planet Technology Switch MGSW 004 12F User Manual
POSIFLEX Business Machines Car Video System LM TM 7115 7115N User Manual
Poulan Lawn Mower 159515 User Manual
Powermate Portable Generator PC052530018 User Manual
PYLE Audio MP3 Player PLCDUSB64MP3 User Manual