Photogenic Professional Lighting Power Supply PLR1000DR User Manual |
Radio-Sync, Constant Color
POWERLIGHT!
Operator’s Manual
Solair! Constant Color PLR500DR
Solair! Constant Color PLR1000DR
Voltage Smart" Solair! PLRX500DR
Voltage Smart" Solair! PLRX1000DR
&
Remote Studio Control Accessories
Download from Www.Somanuals.com. All Manuals Search And Download.
SAFETY PRECAUTIONS
Despite the measures that have been taken to make electronic flash equipment safe,
it must be recognized that high voltages and high temperatures do exist within the
power supply / lighting unit. Certain precautions must be observed in handling the
unit. Contact with internal high voltage may result in severe injury or death.
1. Before installing or removing the flashtube and modeling lamp, be sure this
appliance is turned off, cooled and unplugged from AC power source.
2. Do not touch the glass tubes with bare hands, as normal body oils will shorten the
bulb’s life. Always use a clean cloth or wear gloves to protect your hand from glass
breakage and heat.
3. Do not defeat the purpose to the three-wire line cord by disconnecting the ground.
Connect to properly functioning and grounded 3-pin receptacles only. If you are
using an extension cord, be sure the cord has an equivalent or greater rating and has
a ground.
4. Do not insert a screwdriver or other metal objects into the flashtube socket area or
vents. Contact with high voltage may result.
5. Do not operate this appliance with a frayed or damaged line cord. When replacing
or using the unit with an extension cable, be sure the cable has an equivalent or
greater rating and is a properly connected 3-wire grounded cable.
6. Do not attempt to use this appliance if it has been dropped or damaged, until a
qualified service person has serviced it.
7. Do not operate the unit with a damaged or broken flashtube or modeling lamp. Do
not use flashtubes with broken, cracked or missing glass envelopes. To prevent
damage or injury always use Photogenic specified replacements for the flashtubes
and modeling lamps.
8. Perform no internal service work on this unit. Refer all such service to a qualified
service person or return to the factory. This will provide you safety and
continuation of your warranty.
9. Do not operate when water is present and from extreme temperature shifts. If the
unit is stored in hot or below freezing temperatures, allow at least one hour at room
temperatures before using.
PREPARATION AND BASICS
Unpacking and Setup:
Unpack all units carefully to remove all parts from the carton(s). Do not discard or
destroy the packing material until the equipment has been inspected, assembled, and all
parts accounted for.
After unpacking, all parts should be examined for any damage, which may have been
caused by rough handling during shipment. If any damage is detected, contact the
delivering carrier at once. Claim for damage should be made to the delivering carrier
before destroying packing cartons.
To set up the unit, first mount and secure it on a suitable stand. The PowerLight stand
adapter allows the unit to be mounted on a stand with a 3/8” to 5/8” post. Be sure to use
a stand that is stable and will not tip easily.
Download from Www.Somanuals.com. All Manuals Search And Download.
The unit is shipped with the modeling lamp and flashtube not installed. While installing
the modeling lamp and flashtube (with glove or clean cloth to protect the hand and tube)
be sure they are properly inserted and tight to avoid arcing and failure of the socket
contacts during operation. Do not touch the glass tubes with bare hands, as normal body
oils will shorten the bulb’s life. Always use a clean cloth or wear gloves to protect your
hand from glass breakage and heat.
The 7 _ inch reflector is attached by the “quick-change” mechanism. Three tabs on the
unit grip the ring on the reflector. Finger levers located on the top of the unit control two
of these tabs. To mount the reflector, squeeze the finger levers towards each other and
tilt the reflector past the stationary top-tab, then past the two tabs that are controlled with
the levers. Release the finger levers and make sure all three tabs are securing the
reflector (see illustration below.) All PowerLight accessory reflectors and soft boxes are
designed for use with this “quick-change” system or onto this 7 _ inch reflector
.
Squeeze levers to mount
reflector in locked position.
Punch out hole for
umbrella rod.
Professional plug-in
flashtube.
With power switch OFF, attach the line cord to the power-input connector,
located on the bottom of the PowerLight, and connect it to a grounded wall
outlet. Turn the power switch ON. The READY light will light when the unit
has charged to the power level set by the FLASH power control.
Download from Www.Somanuals.com. All Manuals Search And Download.
DIGITAL CONTROL PANEL AND BASIC OPERATION:
Power Input:
The power required to operate the Solair Radio-Sync, Constant-Color PLR500DR or
PLR1000DR is 105 to 125 volts AC, 60 Hz, 5 Amp. The power cord has a 125V, 15
Amp. rating. [The Voltage Smart Solair Radio-Sync, Constant-Color PLRX500DR or
PLRX1000DR is rated 90 to 250 volts AC, 50/60 Hz, 3.5 Amp and has a 230V power
cord with a German/European plug. These Voltage Smart units have no recharge line
current surge.] Replacement cords or extension cords rated for less amperage may
overheat and should not be used with PowerLights.
Circuit Protection:
Circuit protection automatically protects this appliance from excessive damage due to
circuit or component failure. Operation exceeding the rated cycle of the appliance may
cause the fuse to open. [Always replace fuse with same rating of fuse.] An additional
thermal protector is located inside the PowerLight and may open, if the rated duty cycle
is exceeded. A cooling off period of 10 to 45 minutes is required to reset the thermal
fuse. There is also protection in the microcontroller software which is designed to protect
against exceeding the rated flash cycles. See Diagnostic Display Codes: below.
To replace a blown fuse (power cord must be disconnected), simply unscrew the fuse
holder cap (bottom of unit) and replace the exposed fuse with a new fuse. If fuses
continue to blow, contact your dealer or qualified service person. (See specification
section for fuses replacements)
Power-Up display sequence.
The processor will search the unit for functions that have been activated from the last
time the light was used. As this search is done the first display reads “8888”. Next in the
search sequence is AC and Hertz and you will see 50 or 60 displayed. If Auto-
Bracketing is active you will see =br= followed by the High “H” setting and then the
Low “L” setting. The final standard sequence displays the unit number designated for the
light, 1 through 9. When the search cycle is complete, the display will then show the
setting for flash watt seconds.
“See Advanced Features & Diagnostic Display Codes.
Download from Www.Somanuals.com. All Manuals Search And Download.
Functional Operation
Solair!
Radio-Sync, Constant-Color PLR500DR & PLR1000DR
Voltage Smart,# Radio-Sync, Constant-Color PLRX500DR &
PLRX1000DR
Power Switch:
The power switch controls the AC power to both the modeling and flash circuits. You
have the option to turn-off the modeling circuit independently.
Flash Power:
When the power is turned on the red LED is illuminated. You adjust the PowerLight
Flash power settings by pressing the 1/2 or 1/10 f-stops UP/DOWN arrow buttons. The
watt second settings will be displayed. (If the adjust button is pressed again the modeling
circuit and yellow LED will be turned on.)
Ready Light:
The Solair Radio-Sync, Constant-Color PLR1000DR & PLRX1000DR models are fully
charged when the READY lamp is on. Lowest power (7.8ws) setting charge time is a
maximum of .8 seconds and at full power charge (1000 ws) time is a maximum of 3
seconds. The unit may be flashed before fully charged. When adjusting flash power
settings downward the units will bleed stored power until the lowered power setting is
reached, the ready light will then be re-illuminated.
Download from Www.Somanuals.com. All Manuals Search And Download.
The Solair Radio-Sync, Constant-Color PLR500DR & PLRX500DR models are fully
charged when the READY lamp is on. Lowest power (3.9ws) charge time is a maximum
of .5 seconds and at full power charge (500 ws) time is a maximum of 1.5 seconds. The
unit may be flashed before fully charged. When adjusting flash power settings downward
the units will bleed stored power until the lowered setting is reached, the green READY
light will then be re-illuminated.
Audible READY: The Solair models also have an audible ready feature that will
announce that the stored power has reached the level you have displayed. This feature
can be activated or deactivated by pressing and holding the TEST button until the green
READY light blinks.
Modeling Light:
The modeling light has three modes of operation:
1. MANUAL [press the MANUAL/ADJUST button to turn the MODEL yellow LED
on] adjusts the modeling lamp intensity using the 1/2 or 1/10 f-stops UP/DOWN arrow
buttons. Pressing the MANUAL/ADJUST button a second time will change the mode to
flash adjustment and is indicated by the illuminated red LED
2. TRACK mode (Proportional modeling) causes the modeling lamp intensity to track
the FLASH setting. The modeling lamp may be re-set to full intensity at any FLASH
value, by simply pressing the TRACK/SET button a second time, with the FLASH
already set to desired watt-seconds. This setting is retained when the user returns from
another mode. [Tracking is limited to 6 f-stops.]
3. FULL ON/OFF is exactly what it says. Press the FULL ON/OFF button to turn the
modeling lamp OFF (LED off) or FULL ON (LED on).
Note: All current mode settings are retained, even after the power is turned off.
Test Function:
The TEST button is pressed to fire the flashtube for test purposes, to re-set after a misfire
or to dump stored power when moving to a lower watt second level.
Misfire Indication:
The display will show “- - - -“ if there is a misfire. Press the test button to reset.
Additionally, the Solair PowerLights are equipped with audible alarm if the flash has not
fired properly. This audible feature can be turned ON (LED on) or OFF (LED off) with
the Misfire/Auto bracket button. To activate or deactivate this alarm feature press this
button once. If the yellow light next to the button is illuminated this feature is ON.
Synchronization and Triggering:
Triggering is accomplished by using a built-in PocketWizard! radio receiver, built-in
photoslave or a trigger cable from the power supply to the camera shutter contacts of ”X”
or “zero” delay. Other units in the system are then triggered by photoslave operation.
[All radio-sync PLR units can be triggered with the PocketWizard! PLUS transmitter.]
It is best to connect the fill light directly to the camera since it will be positioned furthest
back in the studio and will usually provide sufficient illumination to trigger the other
units. It is suggested that all walls and ceiling be painted either in white or light neutral
colors for most reliable photoslave operation.
Download from Www.Somanuals.com. All Manuals Search And Download.
After the trigger cord is properly connected, check the synchronization with a film
camera. Adjust the lighting unit to same height as the camera lens and face the lights into
the lens. The lens aperture should be open to its fullest extent and set on “X” or “zero”
delay. Remove the camera back. It is best to perform this test with the modeling lamps
turned off.
While looking at the lens through the back of a film camera, operate the shutter.
A few sheets of white paper in front of the lens will cut down the brilliance of
the flash and aid in making the observation. The flash of the light should then
appear as a circle the same size as the aperture. If the circle is flattened on the
sides, or if no light appears through the lens, the shutter is not synchronized. If
the shutter appears not to be synchronized, a reputable camera repair shop
should check the shutter contacts.
The sync polarity is Positive on center pin of cable connectors (Photogenic part
PLTC, and defined in ISO 518.)
Sync voltage is 12 vdc (Spec. = less than 24 vdc per ISO 10330:1992E, and
greater than 9 vdc for Wein photo slave at 10 microampere drain.) Internal 240
ohm discharge limit, with 68 k ohms continuous limit.
Sync signal = negative pulse, 10 microseconds or longer, from sync voltage to
1.6 vdc or less (per ISO 518.)
PocketWizard! use: The PowerLight built-in receiver is actually 16 channel useable.
The PLUS transmitter is 4 channel. The PowerLight built-in sync radio receiver will
hunt for a signal for 30 seconds after power is applied. If a minimum of four consecutive
triggers are seen during that time period, the receiver will assume that channel. If no
signal is seen, the receiver will operate on whatever channel it was set to before power
was removed. So, turn on the Plus Transmitter and set the channel to 1, 2, 3 or 4. Make
sure the local/both/remote switch is set to either both or remote. Hold the Test button (on
Plus Transmitter) down and turn the PowerLight ON. Continue to hold the transmitter
Test button down for 6 seconds. This should be sufficient time to teach the PowerLight
receiver. When you press the Plus Transmitter Test button subsequently, the PowerLight
will flash. Check transmitter instructions for proper connection to camera and other
details. To prevent the PowerLight photoslave from triggering the flash, you must
insert a SYNC plug (or _” diameter dowel rod) into the _” sync jack.
Download from Www.Somanuals.com. All Manuals Search And Download.
Photocell/Photo Slave:
The sensor is built-in and can be shut off by plugging in the sync cord.
Flash Power Bracketing:
Bracketing refers to taking up to three (3) exposures in a sequence with different
flash intensities, either additional watt seconds or fewer watt seconds, from the
displayed or selected “primary” base intensity. The Solair units enable you to
set the base flash power and then one high and one low bracketing values. Once
the setting(s) have been pre-set, a sequence of power levels will automatically
occur as you take the exposures. If you wish to only bracket up from the
primary, set a HIGH value and leave the LOW value at “0”. If you wish to only
bracket down from the primary, set the HIGH value at “0” and set a LOW value.
The 3-exposure bracketing sequence is:
1. Primary power setting.
2. Higher power pre-set.
3. Lower pre-set.
The 2-exposure bracketing sequence is:
1. Primary power setting.
2. Either Higher or Lower (skips the “0” settings)
To set or change the Auto-Bracketing settings:
1. Press the Auto-Bracketing button 3 times. This will cause the
display to read “br”, then H. .0
2. Press the small up or down (1/10) button to set the HIGH value.
The values can be set at zero “0” to “1.5” f-stops above the
primary power setting.
3. Press the large up (1/2) button once. This will cause the display to
read “L. .0
4. Press the small down or up (1/10) button to set the LOW value.
The values can be set at zero “0” to “1.5” f-stops below the
primary power setting.
5. Press the AUTO-BRACKET button to save these pre-sets.
To turn off the Auto-Bracketing settings:
Setting both the HIGH and the LOW values at zero “0” will turn off the Auto-
Bracket feature.
Note: The auto-bracketing settings are retained and sequenced until the feature
is manually turned off. If the primary power setting is changed the Auto-
Bracketing feature will continue to sequence using the pre-set HIGH and LOW
values from the new primary level.
(This bracketing feature is limited by the 8 f-stops of total watt seconds
available in each model.)
Download from Www.Somanuals.com. All Manuals Search And Download.
Color Temperature
Consistent and Constant
The problem: With the rare exception of units costing many thousands of
dollars, flash lighting packs, up to now, do not control the color temperature of
the light. The color temperature typically decreases by over 100 degrees Kelvin
for every f-stop of power reduction. Over a 6-stop adjustment range, this results
in a color temperature decrease of over 600K. Even units that have a small 3-
stop range can produce significant color shifts of over 300 degrees. This can
result in much larger shifts between two light sources than film can correct.
(Kodak recommends less than 200 degrees shift between light sources for their
5500-degree daylight film.)
The solution: Photogenic has created an affordable solution to this problem.
The new Solaris PowerLights provide consistent and constant color temperature
across their amazing 8-stop range. Be wary of claims of consistent color
temperature at only one power level. This is not the same as constant-color
temperature over all power levels. Both are necessary to provide the perfect
exposure we all strive for. The light produced by the new Solair is consistent &
constant. Every time you key in a desired power level on the digital input, you
will receive the same amount of light as you obtained previously, and at the
same color temperature. The light produced by the new Solair is constant-color.
No matter what power setting you select, the light will be the same color
temperature. Using the standard color corrected flash lamp; every subject will
be exposed to approximately 5400 degree Kelvin light, regardless of power
setting. This solves forever the problem of unbalanced power settings in your
studio, resulting in color temperature shifts in your pictures.
Flash Duration
The Solair PowerLights provide motion-stopping capability ranging from 1/250-
second flash duration at full power to 1/3700 at minimum power, eight stops
down. Unlike shutter speed, flash duration can be reported in different ways. It
is generally defined as the length of time light is produced above a certain power
level. Photogenic Solair measurements are reported at the 1/10 power level or t
= 0.1, instead of several other widely used methods.
While any point of the discharge curve can be utilized to measure the duration of
a flash, the most commonly used are 1/10, 1/3, and 1/2 of peak. ‘Doc’ Edgerton
[Edgerton, “Electronic Flash Strobe”, 1987, pg 30] recommended the 1/3-point
be used for duration measurements in order to approximate the power being
measured. While this has served the industry well for many years, the
commonly available integrating power meter gives the exact amount of power
delivered, and we no longer need to approximate this measurement. The 1/2
Download from Www.Somanuals.com. All Manuals Search And Download.
power point is commonly used in engineering and serves the purpose of
reporting the bandwidth of the flash duration, but the graph below clearly shows
that a power point measurement does not truly report the total flash duration.
The clock doesn’t start running until the flash discharge reaches 50% of its peak,
and stops when it falls below 50%. Since the color temperature of the flash
varies over time (more blue in the beginning and more red towards the tail [pgs
48-60]), it is important that flash duration be reported at the 1/10 power levels to
express the total flash duration and not cut off any of the available flash power.
Flash Duration
t=1/2 Power Duration
1
0.5
0
0
1
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
Time
Total Flash Duration (t=1/10)
You can see that there is quite a bit of light which would be wasted, if we set our
shutter speed to the duration using the t = 1/2 technique. In effect, the flash
duration is longer than you think it is — up to three times longer. So t= 1/2 or t
= 1/3 are not really useful measurements, since we’re used to thinking in terms
of shutter speeds. We at Photogenic want you to get consistent and constant
color temperature and all the flash power you paid for. That’s why we report all
Solair flash durations using the t=1/10 technique. As you can see, setting your
shutter speed to the t=0.1 flash duration or greater will result in your camera
capturing virtually all of the light available.
Download from Www.Somanuals.com. All Manuals Search And Download.
Reciprocity Explained
-Excerpts taken from Kodak TECHNICAL PUBLICATION DATA I FILM
E31- July 2002
The reciprocity law states that the intensity of light falling on a photographic
film multiplied by the exposure time equals the total amount of exposure.
Intensity x Time = Exposure
This means, for example, that an exposure of f 16 at 1/60 second is equivalent
to an exposure of f 11 at 1/125 second. In either combination of settings, the
same total amount of light reaches the film. The reciprocity law applies to
commonly available black-and-white and color films at exposure times from
approximately 1/10 second to 1/1,000 second. This means that no adjustments
are necessary for exposure or color in this shutter range. Most modern films
however have increased this range to the point that no adjustments are necessary
from approximately 1 second to 1/10,000 second. It should be pointed out that
all photographic emulsions are subject to an effect often called “reciprocity-law
failure.” At exposure times at the edges of the above ranges, you will begin to
see underexposure (loss of effective film speed) at the normally calculated
exposure setting, a change in contrast, a color shift, or a combination of these
effects. The word “failure,” in this context, does not imply a short coming of the
film, flash equipment or the camera, but merely that the reciprocity law does not
hold for very long or very short exposures times.
We also sometimes refer to these changes in film response to particular
illumination levels as “long-exposure effects” and “short-exposure effects.”
Download from Www.Somanuals.com. All Manuals Search And Download.
LONG-EXPOSURE EFFECTS
Under low-light conditions, you may have to extend your exposure times to a
point of significant speed loss. With black-and-white films, the effect of this
speed loss is partially offset by wide exposure latitude. Most color films require
more than the normally calculated exposure when the lighting is unusually low.
Also, the sensitivity differences between the many layers of color films can
cause a color-balance shift, which means that you will sometimes need to use
color-compensating filters to achieve an acceptable color balance.
When you must increase the indicated exposure to compensate for long-
exposure effects, use a larger lens opening, if possible. Extending the exposure
time will result in more speed loss, contrast change, and color shift. See the
manufacturers data tables for your specific film to determine what exposure
adjustment and filter may be necessary.
SHORT-EXPOSURE EFFECTS
Extremely short exposures produce essentially the same effect as long
exposures: speed loss. There is also an increased scattering of exposed silver
halide grains, the formation of smaller latent-image centers, and a lower rate of
development at the latent-image centers.
The short-exposure effect appears as lower contrast or reduced density in the
negative. Exposures of 1/10,000 second or shorter can cause this problem.
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATIONAL PARAMETERS
Solair! Radio-Sync, Constant-Color PLR500DR
Voltage Smart# Radio-Sync, Constant Color PLRX500DR
Flashing Rate:
The unit recharges quickly, as indicated by the READY light on the control panel. A
quick series of flashes can be obtained within the limits of the recharge time. Continuous
rapid flashing, however, can overheat and damage the flashtube and internal parts. The
maximum recommended rate of flashing would depend upon the power level being used
and the amount of operation time. Use the following chart to serve as a guide for the
maximum rate to use in your situation.
Power Level
Operating
Time
Sec. Between
Flashes.
Number of
Flashes
Continuous
116
Full
Continuous
11 Minutes
4 Minutes
Continuous
4 Minutes
1.4 Minutes
Continuous
8.3
6
4
4
2
60
1/2
Continuous
124
1
2
85
1/4
Continuous
Exposure Information:
The following charts give the BCPS output for various umbrellas and reflectors.
Coverage angle is given in degrees.
Umbrella
32 inch
45 inch
60 inch
Coverage
120 degree
120 degree
120 degree
Full Power
_
_
1/8
1/16
1/32
1/64
1/128
5500
2750
1375
688
344
172
86
5583
2792
1396
698
349
174
87
5583
2792
1396
698
349
174
87
43
44
44
Reflector
Diameter
Coverage
PL7R
7 _”
35°
PL14R
14”
40°
PL16R
16”
60°
PL18RWD
PL24R
24”
145°
None
360°
18”
126°
Full Power
_
_
1/8
1/16
1/32
1/64
2333
1167
583
292
146
73
25000
12500
6250
3125
1562
781
17500
8750
4375
2188
1094
547
23333
11667
5833
2916
1458
729
3570
1785
892
446
223
112
56
4200
2100
1050
525
262
131
66
37
391
274
365
1/128
18
195
137
182
28
33
GN@ASA100/10’
110
365
305
350
137
150
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIFICATIONS
Solair! Radio-Sync, Constant-Color PLR500DR
Voltage Smart# Radio-Sync, Constant Color PLRX500DR
General:
Flash Power….........................................………...3.9 to 500 watt-seconds.
Maximum (8 f-stops)
Flash Duration….........................................……...1/280 second at Full
1/5800 second at 1/128
Reciprocity……………………………………….Excellent, no filters required
Recycling time…..........................................……..0.5 to 1.5 seconds @ full
Power Control…............................................……Full to 1/128 range.
(8 f-stops)
0.1 f-stop resolution.
Color Temperatures………………………………<±50°K over top 6 f-stops.
<±100°K over entire 8 f-stops.
Modeling Light Power ................................……..250 Watt Quartz, ESS
Modeling Light Control ...............................…….Full to 1/32 range.
0.1 f-stop resolution.
Line voltage regulated.
Triggering ....................................................…….Built-in 16-channel radio receiver
Built in Photoslave.
Push to Test button.
Synchronization Jack.
12 volt isolated.
Main Supply PLR500DR..............................…....105-125 VAC, 60 Hz, 5 amps.
Main Supply PLRX500DR……………………...90-250 VAC, 50/60Hz, 3.5amp.
Consumption PLR500DR......................................0.2 amps idling,
15 amps charging.
Consumption PLRX500DR....................................0.2 amps idling,
5.5 amps charging.
Voltage Stabilization..............................................Plus or minus 0.05 f-stop.
Packaging ..............................................................Extruded Aluminum case.
Weight ...................................................................5.8 pounds, (6.1 lbs. X500DR).
Dimensions PLR500DR (housing only)................4.5” x 4.5” x 6.75”
PLRX500DR (housing only).………4.5” x 4.5” x 9”
Flashtubes and Modeling Lamps:
Flashtube ..................................................……….Plug-in style, use only
Photogenic’s C4-15C or C4-15D.
Modeling Lamp ........................................…….....250-Watt Quartz Halogen
150-Watt Quartz Halogen, ESP.
100-Watt Quartz Halogen, ESR.
Overload Protection Fuse PLR500DR..................3AG type, 16 Amp, SLO-BLO.
Overload Protection Fuse PLRX500DR...............5mmX 20mm, 8 Amp, SLO-BLO
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATIONAL PARAMETERS
Solair! Radio-Sync, Constant-Color PLR1000DR
Voltage Smart# Radio-Sync, Constant Color PLRX1000DR
Flashing Rate:
The unit recharges quickly, as indicated by the READY light on the control panel. A
quick series of flashes can be obtained within the limits of the recharge time. Continuous
rapid flashing, however, can overheat and damage the flashtube and internal parts. The
maximum recommended rate of flashing would depend upon the power level being used
and the amount of operation time. Use the following chart to serve as a guide for the
maximum rate to use in your situation.
Sec. Between
Flashes.
Number of
Flashes
Continuous
40
Power Level
Operating
Time
Full
Continuous
7 Minutes
2.5 Minutes
Continuous
4 Minutes
1.4 Minutes
Continuous
17
10
6
8.3
4
25
1/2
1/4
Continuous
60
2
4
43
Continuous
Exposure Information:
The following charts give the BCPS output for various umbrellas and reflectors.
Coverage angle is given in degrees.
Umbrella
Coverage
32 inch
120 degree
45 inch
120 degree
60 inch
120 degree
Full Power
_
_
1/8
1/16
1/32
1/64
1/128
11000
5500
2750
1375
688
344
172
86
11166
5583
2792
1396
698
349
174
87
11166
5583
2792
1396
698
349
174
87
Reflector
Diameter
Coverage
PL7R
7 _”
35°
PL14R
14”
40°
PL16R
16”
60°
PL18RWD
PL24R
24”
145°
None
360°
18”
126°
Full Power
_
_
1/8
1/16
1/32
1/64
1/128
4666
2333
1167
583
292
146
73
50000
25000
12500
6250
3125
1562
781
35000
17500
8750
4375
2188
1094
547
46666
23333
11667
5833
2916
1458
729
7140
3570
1785
892
446
223
112
56
8400
4200
2100
1050
525
262
131
66
37
391
274
364
GN@ASA100/10’
160
515
430
495
194
210
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIFICATIONS
Solair! Radio-Sync, Constant-Color PLR1000DR
Voltage Smart# Radio-Sync, Constant Color PLRX1000DR
General:
Flash Power............................................…………7.8 to 1000 watt-seconds
maximum. (8 f-stops)
Flash Duration........................................…………1/250 second at Full
1/4000 second at 1/128
Reciprocity………………………………….........Excellent, no filters required
Recycling time..............................................……..0.8 to 3.0 seconds
Power Control...............................................…….Full to 1/128 range.
0.1 f-stop resolution.
Color Temperatures……………………………...<±50°K over top 6 f-stops.
<±100°K over entire 8 f-stops
Modeling Light Power ................................……..250 Watt Quartz, ESS
Modeling Light Control ..............................……..Full to 1/32 range.
0.1 f-stop resolution.
Line voltage regulated.
Triggering.....................................................….….Built-in 16-channel radio receiver
Built in Photoslave.
Push to Test button.
Synchronization Jack.
12 volt isolated.
Main Supply PLR1000DR...............................…..105-125 VAC, 60 Hz, 5 amp.
Main Supply PLRX1000DR……………………..90-250 VAC, 50/60Hz, 3.5amp.
Consumption PLR1000DR.....................................0.2 amps idling,
15 amps charging.
Consumption PLRX1000DR..................................0.2 amps idling,
5.5 amps charging.
Voltage Stabilization ...................................……..Plus or minus 0.05 f-stop.
Packaging .....................................................……..Extruded Aluminum case.
Weight ..........................................................……..7 pounds. (7.8lbs X1000DR)
Dimensions PLR1000DR (housing only)...............4.5” x 4.5” x 8.75”
PLRX1000DR (housing only)…….…4.5” x 4.5” x 11”
Flashtubes and Modeling Lamps:
Flashtube .................................................………..Plug-in style, use only
Photogenic’s C4-19C or C4-19D.
Modeling Lamp ........................................……….250-Watt Quartz Halogen, E
150-Watt Quartz Halogen, ESP.
100-Watt Quartz Halogen, ESR.
Overload Protection Fuse PLR1000DR......….…..3AG type, 16 Amp, SLO-BLO.
Overload Protection Fuse PLRX1000DR.........…..5 X 20mm, 8 Amp, SLO-BLO
Download from Www.Somanuals.com. All Manuals Search And Download.
ADVANCED POWERLIGHT FEATURES
Solair! Radio-Sync, Constant-Color PLR500DR & PLR1000DR
Voltage Smart# Radio-Sync, Constant Color PLRX500DR & PLRX1000DR
Automatic Discharge
Each time the AC line power is disconnected or switched off, the unit will automatically
flash-dump most of the stored power, and then discharge by resistor the remainder of the
stored power. This removes all of the flash capacitor charge to prolong the life of the unit
and is a much safer condition for storage, for transporting, and replacement of flash tube
or modeling lamp. Even if the flash tube is defective or absent, the internal resistor will
discharge all power within 20 seconds after the unit is turned off. This is a feature, over
which the user has no control.
Unit Number Assignment
This feature allows the user to assign a UNIT NUMBER (1 to 9) to each “DR” type
PowerLight in the studio. The UNIT NUMBER is necessary when INFRARED remote
control is used (see accessories.)
To assign a UNIT NUMBER, the startup sequence will need to be interrupted. Turn
PowerLight AC power OFF. With the unit OFF press and hold the _ stop “UP” button
then turn the power switch to ON, continue holding the _ stop button until the display
reads “ir” then release the button. The Digital display should read “ir” when you press
and release the _ UP button again and the display will then read “Un - 1”, or some
number 1 to 9. To change the UNIT number, press and release the 1/10 UP/DOWN
arrow buttons until the desired number is displayed. To save and close the assignment
feature and save the UNIT number, press and release the 1/2 UP arrow button again.
This allows the startup sequence to finish and save the new settings. Each “DR” unit’s
default unit number is set at “Un - 1”. You must re-set the unit number with the 1/10
adjustment buttons, or the default “Un 1” will automatically be assigned.
Wireless Setup.
The “DR” units are pre-set for Infrared wireless operations at the factory and no
adjustments are necessary for operation. Simply plug the PLDIR-2 into the port on the
underside of the unit before turning the AC power ON.
Infrared. To adjust the infrared operation or assign a unit number, the startup sequence
will need to be interrupted. With the unit OFF press and hold the _ stop “UP” button then
turn the power switch to ON, continue holding the _ stop button until the display reads
“ir” then release the button. The Digital display should read “ir” when you press and
release the _ UP button again and the display will read “Un - 1”, or some number 1 to 9.
The next display is for unit number assignment. (See above)
Download from Www.Somanuals.com. All Manuals Search And Download.
During the “ir” display if you then press either of the 1/10 buttons you will display “rado”
pressing the 1/10 button again will display a studio “Su” and number 1 through 4. Studio
numbers are assigned with 1/10 buttons. NOTE: the “rado” is currently an internal-only
system and should not be used if you intend to use infrared controls. To close “rado”,
press the 1/10 button again until the display reads “ir” then press the _ UP button again.
The next display will be “Un 1” which is your light unit number 1 – 9 assignment. You
must re-set the unit number with the 1/10 adjustment buttons, or the default “Un 1” will
automatically be assigned. Once the unit number has been assigned press the _ up button
which allows the startup sequence to finish and save the new settings.
Diagnostic Display Codes:
Circuits that prevent catastrophic damage to your investment protect the Solair and
Voltage Smart Solair PowerLight units.
“Er-0” message means that an AC line power frequency problem has occurred.
This could be internal or in the power cable or outlet at the location. Try
turning the main power off wait for 5 seconds and turn power back on.
“Er-1” message means that an AC line power voltage problem has occurred.
This could be internal or can happen with voltage spikes and voltage fall-off in
the location power supply. Try turning the main power off wait for 5 seconds
and turn power back on.
“Er-3” message means over heating has occurred. This could be internal or by
exceeding the recommended flash frequency. (See flash rate chart) Once “Er-
3” is displayed a “COOL” mode is activated to cool off internal components.
This usually is caused by too many quick-discharges resulting in the
overheating of the unit’s circuits. (See flash rate chart) The unit counts down in
this COOL mode for approximately 4 minutes. This is an electronically timed
period and turning the power OFF will not shorten this period. Therefore, you
must leave the power ON during this COOL-DOWN cycle.
“- - - - “ message means a misfire has occurred. To reset press the test fire
button or turn the power OFF. If the “----“ continues, turn the unit off and have
service performed. Examine the flash tube for damage as this can cause this
misfire message to be illuminated.
Download from Www.Somanuals.com. All Manuals Search And Download.
Advanced Series Accessories
Solair!, Voltage Smart# & PL2 series
PLDIR-2 Remote digital display and Infrared receiver.
(Must be used with PLIRC controller)
The PLDIR-2 is a digital display to enhance visibility and to receive infrared signals to
control the functions of the Solair Constant Color, Radio-Sync PowerLights. It displays
Flash power, Modeling lamp power and unit number. It has a green READY indicator
and a BI-color indicator for Flash or Model. Behind a small window is an infrared
receiver. Resolution is 0.1 f-stop.
The PLDIR-2 may be mounted to the umbrella bracket under the housing of the
PowerLight, on rotating mount, or on an extension cable, for better viewing and
infrared control.
PLIRC-1 Infrared remote controller. (Must be used with PLDIR-2)
Similar to TV, VCR, DTV universal remote controllers, the PLIRC-1 can control up to
nine (9) PowerLights with individual settings. If several PowerLights are used with
identical settings, the same unit number can be assigned to them. This will expand the
total number of lights that can be controlled with the PLIRC-1. All panel button controls
are available, plus STANDBY.
All Solair series PowerLights must have PLDIR-2 infrared receivers and have their
unique unit numbers assigned. PowerLights may have identical unit number numbers, if
they are to be operated exactly the same, under all studio arrangements.
Select a Unit Number on one of the top ten buttons, then control the PowerLight with the
lower buttons, observing the PowerLight digital display for the changes.
The All button, under Unit Number, transmits the changes to all active PowerLights. This
enables the photographer to raise or lower flash or model levels on all the units, without
the laborious task of changing them all, individually.
STANDBY lets the photographer put all the PowerLights into a standby state to stop
public photographers from slaving the units at a wedding, or some studio units can be put
in standby when not required for a shot. The infrared control can easily reach to units on
12-foot stands (it has been tested to 100 feet, indoors.)
PLIBM-1 Studio System Controller software for IBM compatibles.
(Must be used with PLDIR-2 receivers.)
Along with infrared transmitter hardware and an IBM compatible computer, (using
Windows 95, 98, 2000 or XP), the software is used by the photographer to specify the
PowerLight settings for up to nine units with independent settings and save a studio
setting or pose file. An unlimited number of pose files may be saved. All PowerLights
must have PLDIR-2 infrared receivers.
Download from Www.Somanuals.com. All Manuals Search And Download.
General Trouble Shooting
COMMON PROBLEMS AND CAUSES
Unit does not charge. Probable causes:
1. Fuse blown. (Unplug the unit-Replace fuse.)
2. No line power to unit. (Check line cord and outlet.)
3. Internal thermal protection activated. Will occur if power setting is
increased and decreased rapidly, several times. (Wait for unit to cool.
May take 2 to 5 minutes.)
Modeling light does not turn on. Probable causes:
1. Lamp turned off. (Press FULL ON/OFF button until LED lights.)
2. Lamp burned out. (Inspect and replace, when cool. See SERVICE section
of this manual)
3. Internal fuse blown, caused by shorted modeling lamp. (Factory service
required.)
Light flashes by itself without apparent reason. Probable causes:
1. Defective trigger cord, or trigger cord incorrectly polarized.
2. Bright light falling on photo slave.
3. Poor connection in line cord.
4. Reverse connection on trigger cord connection at camera.
5. Some radio slaves will cause interference-consult slave manufacturer.
Trigger cord will not flash unit, but charge indicator shows that the system has charged.
Probable causes:
1. Defective trigger cord.
Defective flashtube. Turn unit OFF. Wait until cool, and then replace flashtube. (See
SERVICE section of this manual)
Infrared not working. Probable causes:
1. Check for receiver model number to insure PLDIR-2 is being used and
has been plugged into the PowerLight properly.
2. Turn unit power OFF and then back ON. The electronic startup sequence
must detect the receiver is being used.
3. View the startup display sequence to insure “ir” is displayed. If “rado” is
displayed see wireless setup in Advanced Features section.
4. If using the Hand-Held controller, press the unit number on the keypad
before pressing any adjustment buttons. If using the Computer control,
you must click transmit at the unit window or transmit-all at the top of the
screen.
Radio-Sync not working. Probable causes:
1. Transmitter...wrong channel or batteries or connection to camera or defective.
2. Built-in receiver...wrong PowerLight model or defective.
Download from Www.Somanuals.com. All Manuals Search And Download.
Limited PowerLight! Warranty
Photogenic Professional Lighting warranties the “standard line” products
are free from defects in material and workmanship of the PL2 series of
PowerLights for a period of two years from date of purchase. At our
choice, we will repair or replace any PL2, Solair or Voltage Smart series
light that is deemed to be defective. This warranty does not cover
damages caused by shipping, product abuse or use other than the
intended photographic applications.
Any product modifications will render this warranty void. Use of
other manufacturer’s accessories, which restrict normal or intended
operation (especially venting airflow), may cause damage and will void
this warranty. Flash tubes are warranted under the above conditions
for one year from date of purchase. Modeling lamps are covered for
initial use failures only.
SERVICE
The photographer should not attempt to make internal repairs.
Consult a dealer for an authorized Photogenic Professional Lighting
service agent. This will provide you safety, insure proper operational
functions and provide continuation of your warranty.
The technicians find it helpful to have the complete unit to better
troubleshoot and evaluate any problems. This includes the light unit, the
power cord, the flash tube and the modeling lamp.
For replacing the flashtube or modeling lamp, follow the directions and
specifications given earlier in this manual in the setup section.
Before removing the old tubes or installing new tubes, always unplug
your PowerLight to discharge the stored energy. Wait approximately 30
seconds for the main capacitors to deplete any residual stored voltage.
Never place your fingers or any metal objects into the flash or modeling
sockets. Contact with high voltage may result.
Download from Www.Somanuals.com. All Manuals Search And Download.
PowerLight! Infrared Studio-Control Accessories.
(For all Digital Remote “DR” models.)
PLCPTR-2 Computer Studio Control System for IBM compatibles.
•
•
•
On-screen display of up to 9 different PowerLight “DR” models.
Set and transmit commands to just one light or the entire studio.
360-degree command coverage for changing flash power, modeling
intensity, proportional modeling sets, modeling ON/OFF, test flash, auto-
bracketing and standby mode.
•
Unlimited pose/light setting files can be named and saved for future recall
when the same pose is repeated.
Includes: Proprietary software, RS232 connector, AC power adapter, and
infrared dome transmitter. (Used with PLDIR-2 receivers sold separately)
PLIRC-1 Hand-Held infrared transmitter.
•
•
Set and transmit commands to just one light or the entire studio.
Transmits commands for changing flash power, modeling intensity,
proportional-modeling sets, modeling ON/OFF, test flash and standby
mode. (Used with PLDIR-2 receivers sold separately)
Includes: Hand-Held transmitter and 9 volt battery.
PLDIR-2 Infrared receiver.
•
•
•
Displays the flash power in watt seconds or the modeling in watts.
Receives the infrared signals from PLCPTR-2 and PLIRC-1 transmitters.
Plugs into any Digital Remote “DR” model of PowerLights. (Used with
PLIRC-1 and PLCPTR-2 transmitters sold separately)
Includes: Receiver/display and flexible cable to attach to PowerLights.
Download from Www.Somanuals.com. All Manuals Search And Download.
POWERLIGHT! QUICK-CHANGE#
ACCESSORIES
REFLECTORS:
PL3R ------3” Shallow Background reflector rotates to control light for high key and back
lighting.
PL3RV-----3” Veil Slotted Background reflector for veil and burst-lighting
PL5R-------5” Deep Conical Background reflector.
PL7R-------7 _” Standard high grain reflector. 35-degree coverage.
PL14R-----14” Parabolic for portraits, feathering, flood and fill lighting.
45-degree coverage.
PL16R-----16” Parabolic for portraits, feathering, flood and fill lighting.
60-degree coverage.
PL18R-----18” Parabolic for soft illumination and flood lighting.
125-degree coverage.
PL20R-----20” Parabolic for portraits, feathering, flood and fill lighting.
65-degree coverage.
PL24R-----24” Parabolic for soft illumination and flood lighting.
145-degree coverage.
Additional PowerLight Light-Shaping Accessory items and Kits.
Grids.
Snoots.
Soft Boxes.
Barndoor Sets.
Tilting Handle.
Scrim & Gel rings.
Eclipse Umbrellas.
Counter-Balance weights.
Contact your local dealer for these and other Professional Photographic products by:
Photogenic Professional Lighting
1268 Humbracht Circle, Bartlett, Illinois 60103-1631
Telephone: (630)830-2500 Fax: (630)830-2525
MANUAL PART NO. 016577-00V0-6-05
Download from Www.Somanuals.com. All Manuals Search And Download.
|