Philips TuffGuard™ High
Intensity Discharge
Coated Lamps
Ideal for manufacturing and
warehouse applications
TUFFGUARD™ SERIES
Outstanding performance
and reliability
Philips TuffGuard™ High Intensity Discharge Coated Lamps
offer a range of switch start and high pressure sodium lamps
that provide long life, high efficiency and high lumen output.
PhilipsTuffGuard™ coated lamps
• Contains glass fragments in the event the lamp is accidentally
dropped or broken
• Easy-to-clean non-stick coating
Coating is not designed to contain an arc-tube rupture
Download from Www.Somanuals.com. All Manuals Search And Download.
PhilipsTuffGuard™ High Intensity Discharge
Coated Lamps—Protected Metal Halide
“O” Rated Lamps
Ordering, Electrical andTechnical Data
Max.
Rated
Approx.
Initial
Lumens2
Product
Number
Nom.
Watts
Pkg.
Qty.
Avg. Life
(Hrs)1
Description
Volts
Bulb
Base
Availability
20214-3
20215-0
21148-2
20216-8
MP175/BU 12PK TG
MP250/BU 12PK TG
MP360/BU/EW 6PK TG
MP400/BU 6PK TG
175
250
360
400
132
133
120
135
12
12
6
ED-28
ED-28
ED-37
ED-37
Mogul
Mogul
Mogul
Mogul
10,000
10,000
20,000
20,000
15,000
22,000
34,200
38,000
Stocked
Made to Order
Stocked
6
Stocked
1) Average life under engineering data with lamps turned off and restarted once every 12 operating hours.
2) Protective coating may reduce actual lumens by up to 5%.
Above specifications are subject to change without notice.
Made to order requires 3 week lead time
(No product returns on made to order lamps)
WARNINGS:
• Coating can withstand bulb wall temperatures up to 500°F, subject to the following conditions:
1) Lamp must be installed and operated in ambient temperature below 150°F.
2) Lamp is not used in fixture that does not allow heat dissipation.
• UV radiation emitted from metal halide lamps may deteriorate the coating over time.
•The coating is not designed to contain an arc-tube rupture
• Under extreme conditions glass fragments may escape the coating
• Lamps must be burned base up only
• Only protective shrouded lamps are resistant to metal halide non-passive failure.
LAMP OPERATING INSTRUCTIONS:
RECOMMENDED WARNINGS, CAUTIONS,AND OPERATING INSTRUCTIONS
For Protected Metal Halide Lamps (Base Up Operation 15˚ Unless Noted;
Open or Enclosed Fixtures)
1. RELAMP FIXTURES AT OR BEFORETHE END OF RATED LIFE.Allowing lamps to operate until
they fail is not advised and may increase the possibility of inner arc tube rupture.
2. Before lamp installation/replacement, shut power off and allow lamp and fixture to cool to avoid electrical
shock and potential burn hazards.
“WARNING:These lamps can cause serious skin burn and eye inflammation from short wave ultraviolet
Rradiation if outer envelope of the lamp is broken or punctured. Do not use where people will remain for
more than a few minutes unless adequate shielding or other safety precautions are used. Certain lamps that will
automatically extinguish when the outer envelope is broken or punctured are commercially available.”This lamp
complies with FDA radiation performance standard 21 CFR subchapter J. (USA: 21CFR 1040.30 Canada:
SOR/DORS/80-381)
3. Use only auxiliary equipment meeting Philips and/or ANSI standards. Use within voltage limits recommended
by ballast manufacturer.
A.Operate lamp only within specified limits of operation.
B. For total supply load refer to ballast manufacturers electrical data.
If the outer bulb is broken or punctured, turn off at once and replace the lamp to avoid possible
injury from hazardous short wave ultraviolet radiation. Do not scratch the outer bulb or subject
it to pressure as this could cause the outer bulb to crack or shatter.A partial vacuum in the
outer bulb may cause glass to fly if the envelope is struck.
4. Periodically inspect the outer envelope. Replace any lamps that show scratches, cracks or damage.
5. If a lamp bulb support is used, be sure to insulate the support electrically to avoid possible decomposition of
the bulb glass.
6. Protect lamp base, socket and wiring against moisture, corrosive atmospheres and excessive heat.
WARNING: The arc-tube of metal halide lamps are designed to operate under high pressure and at temperatures
up to 1000º C and can unexpectedly rupture due to internal or external factors such as a ballast failure or
misapplication. If the arc-tube ruptures for any reason, the outer bulb may break and pieces of extremely hot
glass might be discharged into the surrounding environment. If such a rupture were to happen,
7. Time should be allowed for lamps to stabilize in color when turned on for the first time.This may require
several hours of operation, with more than one start. Lamp color is also subject to change under conditions
of excess vibration or shock and color appearance may vary between individual lamps.
THERE ISA RISK OF PERSONAL INJURY, PROPERTY DAMAGE, BURNS AND FIRE.
8. Lamps may require 10 to 20 minutes to re-light if there is a power interruption.
These lamps are designed to retain all the glass particles should an arc tube rupture occur.The
following operating instructions are recommended to minimize these occurrences. RELAMP
FIXTURES AT OR BEFORETHE END OF RATED LIFE.Allowing lamps to operate until they
fail is not advised and may increase the possibility of inner arc tube rupture.
9. Take care in handling and disposing of lamps. If an arc tube is broken, avoid skin contact with any of the con-
tents or fragments.
10 Do not use this lamp:
A. In a fixture that contains a Pulse Start metal halide ballast.
CAUTION: TO REDUCETHE RISK OF PERSONAL INJURY, PROPERTY DAMAGE, BURNS AND FIRE
RESULTING FROM AN ARC-TUBE RUPTURETHE FOLLOWING LAMP OPERATING INSTRUCTIONS
MUST BE FOLLOWED:
B. In a fixture that is specifically designed for use with Pulse Start metal halide lamps.Operation of these lamps
on Pulse Start Metal Halide systems may increase the chance of an outer bulb rupture and pieces of
extremely hot glass might be discharged into the surrounding environment. If such a rupture were to happen,
THERE IS A RISK OF PERSONAL INJURY, PROPERTY DAMAGE, BURNS AND FIRE.
Download from Www.Somanuals.com. All Manuals Search And Download.
PhilipsTuffGuard™ High Intensity Discharge
Coated Lamps—HPS Lamps
Ordering, Electrical andTechnical Data
Max.
Rated
Approx.
Initial
Product
Number
Nom.
Watts
Pkg.
Qty.
Avg. Life
Description
Volts
Bulb
ED-231⁄
ED-231⁄
Base
(Hrs)1
Lumens2
Availability
20218-4
20219-2
20220-0
20222-6
20458-6
20460-2
C70S62 12PK TG
C100S54 12PK TG
C150S55 12PK TG
C250S50 12PK TG
C50S68/M 12PK TG
C100S54/M 12PK TG
70
100
150
250
50
52
55
55
100
52
55
12
12
12
12
12
12
2
Mogul
Mogul
Mogul
Mogul
Medium
Medium
24,000
24,000
24,000
24,000
24,000
24,000
6500
9400
15,800
27,000
4000
Made to Order
Made to Order
Made to Order
Stocked
Made to Order
Made to Order
2
ED-231⁄
ED-18
BF-55
BF-55
2
100
9500
1) Average life under engineering data with lamps turned off and restarted once every 12 operating hours.
2) Protective coating may reduce actual lumens by up to 5%.
Made to order requires 3 week lead time
Above specifications are subject to change without notice.
(No product returns on made to order lamps)
WARNINGS:
• Coating can withstand bulb wall temperatures up to 500°F, subject to the following conditions:
1) Lamp must be installed and operated in ambient temperature below 150°F.
2) Lamp is not used in fixture that does not allow heat dissipation.
4. Replace the lamp if the outer glass bulb has been scratched, cracked or damaged in any way.
RECOMMENDED WARNINGS, CAUTIONS,AND OPERATING INSTRUCTIONS
For High Pressure Sodium Lamps
“WARNING:These lamps must be operated in fixtures designed for use with High Pressure Sodium
Rlamps.The fixture wattage rating must match the wattage indicated on the outer glass bulb. Do not scratch
the outer bulb or subject it to pressure as this could cause the outer bulb to crack or shatter.A partial vacuum
in the outer bulb may cause glass to fly if the glass is struck.Operating the lamp improperly may result in
PERSONAL INJURY, PROPERTY DAMAGE, BURNS AND FIRE.
5. If a lamp bulb support is used, be sure to insulate the support electrically so as to avoid possible decomposition
of the bulb glass.
6. Do not use this lamp in a fixture which redirects a substantial portion of the energy toward the arc tube and
its immediate vicinity, as this may lead to very early lamp failure.
7. Take care in handling and disposing of lamps. If arc tube is broken, avoid skin contact with any of the contents
or fragments.
1. If the outer glass bulb is broken, shut off power immediately and remove the lamp after it has cooled.
8. The arc tube of this lamp contains sodium and mercury. Dispose of in accordance with federal, state and local
requirements.
2. Use only auxiliary equipment meeting Philips and/or ANSI standards. Use within voltage limits recommended
by ballast manufacturer.
A.Operate lamp only within specified limits of operation.
B. For total supply load refer to ballast manufacturers electrical data.
3. Protect lamp base, socket and wiring against moisture, corrosive atmospheres and excessive heat.
© 2007 Philips Lighting Company.All rights reserved.
Printed in USA 08/07
Philips Lighting Company
200 Franklin Square Drive
P.O. Box 6800
Somerset, NJ 08875-6800
1-800-555-0050
Philips Lighting
281 Hillmount Road
Markham, Ontario
Canada L6C 2S3
P-5813-B
1-800-555-0050
A Division of Philips Electronics North America Corporation
A Division of Philips Electronics Ltd.
Printed on chlorine free paper from Sappi Fine Paper mills, who are accredited with EMAS environmental certification.
Sappi claims that the pulp used in the manufacture of Magno Dull paper is derived from environmentally certified forests.
Download from Www.Somanuals.com. All Manuals Search And Download.
|