A simple change for
significant impact
Philips Energy AdvantageT8 25W Lamps
Download from Www.Somanuals.com. All Manuals Search And Download.
Why choose the Philips Energy AdvantageT8 25W over theT8 32W lamps?
• It’s a simple way to immediately save money.All you need to do is replace your existing
T8 32W. No ballast change required
• It reduces your energy consumption which saves you money
• It provides outstanding light quality—97% lumen maintenance and 85 CRI
• It’s better for the environment with extremely low mercury
ReduceYour Energy Costs: Save 7 Watts Instantly!
StandardT8 32W Lamp vs. Philips Energy AdvantageT8 25W Lamp
Philips Energy Advantage
T8 25W Lamps vs.
StandardT8 32W Lamps
Annual operating hours
Savings Over Lamp Life
(12 hours/day) (24 hours/day)
(30,000 hrs Rated Average Life)
kWh
Rate
4380 hours1
8760 hours2
1 lamp
4 lamps
0.06
0.08
0.10
0.12
0.15
0.20
$1.84
$2.45
$3.07
$3.68
$4.60
$6.13
$3.68
$4.91
$6.13
$7.36
$9.20
$12.26
$12.60
$16.80
$21.00
$25.20
$31.50
$42.00
$50.40
$67.20
$84.00
$100.80
$126.00
$168.00
Why choose the Philips Energy AdvantageT8 25W Extra Long Life
over theT8 32W lamps?
• It’s a great way to reduce your maintenance costs by extending the relamping cycle
• It’s a simple way to immediately save money. All you need to do is replace
your existingT8 32W. No ballast change required
• It reduces your energy consumption which saves you money
• It provides outstanding light quality—97% lumen maintenance and 85 CRI
• It’s better for the environment with extremely low mercury
Philips Energy Advantage
T8 25W Extra Long Life
Lamps vs. StandardT8
32W Lamps
ReduceYour Energy Costs: Save 7 Watts Instantly!
StandardT8 32W Lamp vs. Philips Energy AdvantageT8 25W
Extra Long Life Lamp
Annual operating hours
Savings Over Lamp Life
(12 hours/day) (24 hours/day)
(30,000 hrs Rated Average Life)
kWh
Rate
4380 hours1
8760 hours2
1 lamp
4 lamps
0.06
0.08
0.10
0.12
0.15
0.20
$1.84
$2.45
$3.07
$3.68
$4.60
$6.13
$3.68
$4.91
$6.13
$7.36
$9.20
$12.26
$16.80
$22.40
$28.00
$33.60
$42.00
$56.00
$67.20
$89.60
$112.00
$134.40
$168.00
$224.00
Download from Www.Somanuals.com. All Manuals Search And Download.
Philips Energy Advantage
T8 25W Lamps and Philips
Advance Optanium® Ballasts
Save even more when you pair Philips Energy
AdvantageT8 25W Lamps with Philips Advance
Optanium® ballasts.
• It can help reduce energy consumption by over
40% relative to older systems involvingT12 lamps
and magnetic ballasts
Developed jointly to optimize performance, combining a
Philips Lighting’s Energy AdvantageT8 25W lamp featuring
ALTO II™ Technology with a Philips Advance Optanium®
high efficiency electronic ballast creates one of the lowest
energy-consuming 4-footT8 systems on the market.
• It can help reduce energy consumption by 20–30%
relative to systems utilizing conventionalT8 lamps
and electronic ballasts
• It is suitable for both new construction and
retrofit applications
• It provides maximum-efficiency and high-performance
Why choose a system which includes Philips Energy
AdvantageT8 25W Extra Long Life lamps and a Philips
Advance Optanium® high efficiency electronic ballast?
• It is a sustainable lighting solution for today’s general
office, healthcare, education facilities, retail, and
warehouse settings
• It’s optimized by Philips Lighting and Philips Lighting
Electronics N.A. for energy efficiency on both Instant
and Programmed Start lamp ignition
• It provides a range of powerful features
ReduceYour Energy Costs: Save 27 Watts Instantly!
StandardT8 32W System vs. Optanium® Instant Start Electronic Ballast with a PhilipsT8 25W
StandardT8 32W with a
Standard Instant Start System
Energy AdvantageT8 25W with a High-efficiency
Optanium Instant Start Electronic Ballast
Lamp and Ballast
CRI
Ballast Factor3
78
85
0.88
2800
95%
3
0.87
2500
97%
4
Approx.Initial Lumens4,5
Lumen Maintenance
Number of Lamps
Maintained Lumens6
System Wattage
7022
88
8439
85
Make the Switch and Here is WhatYou Can Save...
Watts Saved...........................................................27Watts Saved
Annual Savings in Energy Costs........................$2.96 Per Lamp7
Energy Saved (in Dollars) ...................................$20.27 Per Lamp8 Over Rated Average Life9
(See back page for footnotes)
Download from Www.Somanuals.com. All Manuals Search And Download.
Extend your
relamp cycle
Philips Energy AdvantageT8 25W Lamps
Ordering, Electrical andTechnical Data (Subject to change without notice)
Color
Temp.
(Kelvin)
Nom.
Length
(In.)
Rated Average Life (hrs)9
Approx.
Initial
Product Ordering
Number Code
Pack.
Qty.
12-hr on
Ins. Start
12-hr on
Prog. Start
Design
Lumen
Maint.
Watts
Lumens10 Lumens11
CRI
13781-0
13782-8
13783-6
13784-4
F32T8/ADV830/XEW/ALTO
25
25
25
25
25
25
25
25
3000
3500
4100
5000
48
48
48
48
30,000
30,000
30,000
30,000
36,000
36,000
36,000
36,000
2500
2500
2500
2400
2425
2425
2425
2330
85
85
85
85
97%
97%
97%
97%
F32T8/ADV835/XEW/ALTO
F32T8/ADV841/XEW/ALTO
F32T8/ADV850/XEW/ALTO
Philips Energy AdvantageT8 25W Extra Long Life Lamps
Ordering, Electrical andTechnical Data (Subject to change without notice)
Color
Temp.
(Kelvin)
Nom.
Length
(In.)
Rated Average Life (hrs)9
Approx.
Initial
Product Ordering
Number Code
Pack.
Qty.
12-hr on
Ins. Start
12-hr on
Prog. Start
Design
Lumen
Maint.
Watts
Lumens10 Lumens11
CRI
15206-6
15207-4
15208-2
15209-0
F32T8/ADV830/XLL/ALTO
25
25
25
25
25
25
25
25
3000
3500
4100
5000
48
48
48
48
40,000
40,000
40,000
40,000
46,000
46,000
46,000
46,000
2400
2400
2400
2350
2330
2330
2330
2280
85
85
85
85
97%
97%
97%
97%
F32T8/ADV835/XLL/ALTO
F32T8/ADV841/XLL/ALTO
F32T8/ADV850/XLL/ALTO
Philips Advance Optanium® High Efficiency IntelliVolt® Instant Start Ballasts
Ordering, Electrical andTechnical Data (Subject to change without notice)
Min.
Starting
Temp. (˚F/˚C) Volts
Min. Power
Factor
(Measured)
No. of
Lamps
Input
Ballast
Family
Catalog
Number
Line Current
(Amps)
Input Power
ANSI (Watt)
Ballast
Factor
MaxTHD%
(Measured)
1
1
1
1
1
1
1
1
2
2
2
2
2
2
2
2
3
3
3
3
3
3
3
3
4
4
4
4
60°/15°
60°/15°
60°/15°
60°/15°
60°/15°
60°/15°
60°/15°
60°/15°
60°/15°
60°/15°
60°/15°
60°/15°
60°/15°
60°/15°
60°/15°
60°/15°
60°/15°
60°/15°
60°/15°
60°/15°
60°/15°
60°/15°
60°/15°
60°/15°
60°/15°
60°/15°
60°/15°
60°/15°
120
120
277
277
120
120
277
277
120
120
277
277
120
120
277
277
120
120
277
277
120
120
277
277
120
120
277
277
Optanium
Optanium
Optanium
Optanium
Optanium
Optanium
Optanium
Optanium
Optanium
Optanium
Optanium
Optanium
Optanium
Optanium
Optanium
Optanium
Optanium
Optanium
Optanium
Optanium
Optanium
Optanium
Optanium
Optanium
Optanium
Optanium
Optanium
Optanium
IOP-1P32-SC
IOPA-1P32-SC
IOP-1P32-SC
IOPA-1P32-SC
IOP-2P32-SC
IOPA-2P32-SC
IOP-2P32-SC
IOPA-2P32-SC
IOP-2P32-SC
IOPA-2P32-SC
IOP-2P32-SC
IOPA-2P32-SC
IOP-3P32-SC
IOPA-3P32-SC
IOP-3P32-SC
IOPA-3P32-SC
IOP-3P32-SC
IOPA-3P32-SC
IOP-3P32-SC
IOPA-3P32-SC
IOP-4P32-SC
IOPA-4P32-SC
IOP-4P32-SC
IOPA-4P32-SC
IOP-4P32-SC
IOPA-4P32-SC
IOP-4P32-SC
IOPA-4P32-SC
0.20
0.20
0.09
0.09
0.23
0.23
0.10
0.10
0.37
0.37
0.16
0.16
0.42
0.42
0.18
0.18
0.55
0.55
0.24
0.24
0.59
0.59
0.26
0.26
0.73
0.73
0.31
0.31
23
23
23
23
27
27
27
27
44
44
43
43
49
49
49
49
65
65
64
64
70
70
69
69
87
87
85
85
0.87
0.87
0.87
0.87
1.05
1.05
1.05
1.05
0.87
0.87
0.87
0.87
1.00
1.00
1.00
1.00
0.87
0.87
0.87
0.87
0.97
0.97
0.97
0.97
0.87
0.87
0.87
0.87
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
0.99
0.99
0.98
0.98
0.99
0.99
0.97
0.97
0.99
0.99
0.98
0.98
0.99
0.99
0.97
0.97
0.99
0.99
0.98
0.98
0.99
0.99
0.97
0.97
0.99
0.99
0.98
0.98
(See back page for footnotes)
Download from Www.Somanuals.com. All Manuals Search And Download.
FOOTNOTES:
* Not available in IOPA models.
1) 4380 based on operating the lamps 12 hours per day/7 days a week.
2) 8760 based on operating the lamps 24 hours per day/7 days a week.
3) Ballast Factor (BF): Measure of light output from lamp operated by commercial ballast, as compared to a laboratory standard reference ballast.
4) Approximate initial lumens.The lamp lumen output is based upon lamp performance after 100 hours of operating life, when the output is measured during operation
on a reference ballast under standard laboratory conditions.
5) For expected lamp lumen output, commercial ballast manufacturers can advise the appropriate ballast factor for each of their ballasts when they are informed of the
designated lamp. The ballast factor is a multiplier applied to the designated lamp lumen output.
6) Maintained lumens = Approx. initial lumens x ballast factor x lumen maintenance x number of lamps.
7) Based on watts saved per lamp x annual operating hours (4380) x kWh rate ($0.10) / 1000 / 3. Kilowatt hour rate may vary depending on location and energy company.
8) Based on watts saved per lamp x rated average life (36,000 hrs) x kWh rate ($0.10) / 1000 / 3. Kilowatt hour rate may vary depending on location and energy company.
9) Average life under engineering data with lamps turned off and restarted once every 12 operating hours.
10) Approximate initial lumens.The lamp lumen output is based upon lamp performance after 100 hours of operating life, when the output is measured during operation on
a reference ballast under standard laboratory conditions. For expected lamp lumen output, commercial ballast manufacturers can advise the appropriate ballast factor for
each of their ballasts when they are informed of the designated lamp.The ballast factor is a multiplier applied to the designated lamp lumen output.
11) Design lumens are the approximate lamp lumen output at 40% of the lamp’s rated average life.This output is based upon measurements obtained during lamp operation
on a reference ballast under standard laboratory conditions.
© 2009 Philips Lighting Company.
All rights reserved.
Printed in USA 7/09
Philips Lighting Company
200 Franklin Square Drive
P.O. Box 6800
Somerset, NJ 08875-6800
1-800-555-0050
Philips Lighting
Philips Lighting Electronics N.A.
10275West Higgins Road
Rosemont, IL 60018-5603
1-800-322-2086
281 Hillmount Road
Markham, Ontario
Canada L6C 2S3
P-5671-B
1-800-555-0050
A Division of Philips Electronics
North America Corporation
A Division of Philips Electronics Ltd.