Thank you for choosing the PetSafe® brand. You and your pet deserve a companionship that includes memorable moments and a shared understanding together. Our products and training tools  
promote a lifestyle of protection, teaching, and love—essentials that influence memories for a lifetime. If you have any questions about our products or training your pet, please visit our website at  
www.petsafe.net or contact our Customer Care Center at 1-800-732-2677.  
PRODUCT WARRANTY  
full warranty and should you ever need to call the Customer Care Center, we will be able to help you faster. Most importantly, PetSafe® will never give or sell your valuable information to anyone.  
Complete warranty information is available online at www.petsafe.net.  
INSTRUCTIONS PERTAINING TO; RISK OF FIRE, ELECTRIC SHOCK  
OR HARM TO PERSONS  
IMPORTANT SAFETY INSTRUCTIONS  
SAVE THESE INSTRUCTIONS  
Setup and Operating Instructions: Before using the hy·drate, Pet H2O  
Filtration System for the first time, it is important that you properly prepare  
the product for use. The hy·drateincludes a filter that should be thoroughly  
rinsed to remove the carbon filter dust. Don’t worry; the dust is not harmful to  
your pet. For smaller bowls you will find it helpful to adjust the flow control to  
prevent water from splashing from the bowl.  
Begin by opening the hy·drate, using your thumb to lift the snap located  
on the back to open the outer shell. Note the orientation of the internal parts  
and the location of the flow control on the side of the pump (See Fig. 1a &  
1c). Remove the filter and rinse it under running water for approximately 20  
seconds or until no carbon dust is showing in water. Gently shake excess  
water off filter and place back into the upper shell (See Fig. 1a). Close the  
hy·drateback together.  
When using electric appliances, basic precautions should always be followed,  
including the following:  
• Read all the instructions before using appliance.  
To reduce the risk of injury, close supervision is necessary when an  
appliance is used near children.  
• Only use attachments recommended or sold by the manufacturer.  
• Do not use outdoors. INTENDED FOR INDOOR HOUSEHOLD  
USE ONLY.  
• Do not unplug by pulling on the cord. To unplug, grasp the plug, not  
the cord.  
• Do not operate any appliance with a damaged cord or plug, or after the  
appliance malfunctions or is dropped or damaged in any manner. Return  
appliance to the nearest authorized service facility for examination, repair,  
or electrical or mechanical adjustment.  
• For a portable appliance – To reduce the risk of electrical shock, do not  
place or store appliance where it can fall or be pulled into a tub or sink.  
• Always unplug any appliance when not in use, before putting on or taking  
off parts, and before cleaning. Never yank a cord to remove from  
the outlet.  
Fit the hy·drateto the bottom of your pet’s bowl and push down until all  
three suction cups are secured to bottom. Use the suction cup on the pump’s  
power cord to neatly attach cord to the outside of the bowl. Fill the bowl  
with water so the hy·drateis fully submerged. The low-voltage submersible  
pump is safe to fully go under water. Attach the pump’s power cord to the  
AC adapter power cord, dry your hands and plug into a standard 120 volt AC  
circuit outlet. The hy·dratewill start and within 20 seconds water will flow  
from the water flow opening. To turn off the hy·drate, unplug from the outlet.  
Some pets prefer drinking from a running source of water. To create a water  
stream effect, maintain a water level at the minimum H2O level noted on the  
hy·drate(See Fig. 1a). Level of water above the hy·dratewill give a rippling  
or bubbling effect on top of the water. Both options provide continuous  
movement and filtration for cleaner, fresher water. Now, adjust the flow control  
on the pump based on the size of the bowl, desired flow of water or to reduce  
water splattering from the bowl (See Fig. 1a & 1c). After beginning operation  
of the hy·drate, simply allow your pet to adjust at his or her own pace. Some  
pets may take several days or longer to begin use. After your pet is acclimated  
to the hy·drate, continue to replenish your pet’s drinking water frequently for  
maximum hydration.  
• Do not contact moving parts.  
• Always position power cords out of the way of foot traffic to avoid tripping.  
• Do not allow your pet to chew on the power cord or hy·drateproduct.  
• If the AC adapter gets wet, turnoff electricity to that outlet. Do not  
attempt to unplug.  
• Examine this appliance after installation. It should not be plugged in if  
there is water on the cord or plug. To avoid the possibility of the plug  
or outlet getting wet, the outlet should always be above the level of  
the hy·drate.  
• Do not submerse AC power adapter into water.  
It is not recommended that any appliance be left running unattended for a  
prolonged period of time as the water may get consumed or evaporate, thus  
causing the motor to run dry and can reduce life of the pump.  
Cleaning Instructions: The hy·drateupper shell, lower shell with suction  
cups and pump connector are dishwasher safe at low temperatures or can  
be hand washed with warm soapy water. THE PUMP IS NOT DISHWASHER  
SAFE! To remove pump from upper shell push in rubber fitting towards  
pump to release. Thread pump power cord through suction cup loop and  
pump cord pass-through (See Fig. 1a & 1b). The hy·dratepump should be  
disassembled and cleaned every two weeks (See Fig. 2 & 3). To remove “hard  
water” mineral build-up soak disassembled pump in regular white vinegar for  
several minutes and rinse thoroughly. Once the parts are clean, reassemble  
the pump by replacing the impeller, stator, ow control (See Fig. 4) and the  
intake plate. Thread pump power cord back through pump cord pass-through  
and suction cup loop, and position pump onto the pump connector post in  
the upper shell (See Fig. 1a & 1b). Grasp the rubber fitting and pull through  
hole in upper shell until it snaps into place sealing the opening (See Fig. 1a &  
1b). The length of the pump power cord may need to be adjusted by pulling  
either end to position pump onto pump connector post.  
The filter should be replaced every 2 - 4 weeks to maintain filtered, fresh and  
clean water. Small food particles and hair must be cleaned between the intake  
and filter as needed to maintain strong current flow.  
IMPORTANT: Warranty may be voided if pump is not cleaned regularly.  
Product Specifications:  
Voltage/Power Consumption 120VAC 60Hz 3.3 WATTS  
12 Volts low-level power adapter output  
Accessories:  
To purchase replacement parts or accessories, contact PetSafe® Customer  
Care Center at 1-800-732-2677 or by visiting www.petsafe.net.  
Replaceable Filters, 3-pack  
PFD17-12905  
Fig. 2  
Fig. 3  
Fig. 4  
Terms of Use and Limitations of Liability  
1. Terms and Use - This product is offered to you conditioned upon your acceptance  
without modifications of the terms, conditions and notices contained herein. Use of  
this product implies acceptance of all such terms, conditions and notices.  
Impeller  
Flow  
Control  
2. Proper Use - Includes reviewing the safety precautions listed.  
Pump  
3. No Unlawful or Prohibited Use - This product is designed for pets only. This device is  
not intended to harm, injure or provoke your pet. Using this product in a way that is  
not intended could result in violation of Federal, State or local law.  
4. Limitations of Liability - In no event shall Radio Systems® Corporation be liable for any  
direct, indirect, punitive, incidental, special or consequential damages whatsoever  
arising out of or connected with the use or misuse of this product. Buyer assumes all  
risks and liabilities from the use of this product.  
Stator  
Intake Plate  
With your thumb and forefinger,  
gently squeeze the sides of  
intake plate, and pull off.  
Remove the flow control, stator  
and impeller. To remove impeller cavity and remove any  
use a fingernail to lift out; it is  
held in magnetically.  
Clean with warm soapy  
water. Use a cotton swab placing post into opening  
or a small cleaning brush on the pump motor. Align  
to get into the motor  
Replace flow control by  
flow control knob to  
opening on intake plate  
and attach intake plate  
to pump.  
5. Modifications of Terms and Conditions - Radio Systems® Corporation reserves the  
right to change the terms, conditions and notices under which this product is offered.  
build-up.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Pentair Landscape Lighting AmerQuartz User Manual
Pentax Digital Camera 16926 User Manual
Petsafe Paint Sprayer PDT19 11980 User Manual
Philips Cassette Player AW 7491 User Manual
Philips Fryer HD9240 User Manual
Philips Home Theater Screen SVC3500W User Manual
Philips Surge Protector SPP1180WA 37 User Manual
Philips Switch PIP3207 DC User Manual
Polaroid Scanner 45 Ultra User Manual
Poulan Lawn Mower Accessory 532182124 User Manual