Pentair Water Dispenser 40106 Rev H 05 05 User Manual

Model 5600 & 5600 Econominder®  
Service Manual  
IMPORTANT: Fill in pertinent information on page 3 for future reference.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Model 5600 & 5600 Econominder®  
Job Specification Sheet  
Job Number ___________________________________  
Model Number ________________________________  
Water Test ____________________________________  
Capacity of Unit ________________________ Max. _____________ Per Regeneration  
Mineral Tank Size: Diameter ___________________ Height _____________________  
Brine Tank Size and Salt Setting Per Regeneration: ___________________________________  
Control Valve Specifications  
Type of Timer: ___ Std.  
___ "L"  
___ 7-day  
___ 12-day  
___ Meter, Std.  
___ Meter, Ext.  
Day/Time of Regeneration _____________________________  
Drain Line Flow Control _______________________________ gpm  
Brine Refill Rate _____________________________________ gpm  
Injector Size ________________________________________  
Meter Gallon Setting _________________________________ gal  
Slow Rinse  
Rate (gpm)  
@ 40 psi  
Brine Draw  
Rate (gpm)  
@ 40 psi  
Tank Size  
(diameter)  
Injector  
BLFC1  
BLFC2  
6"  
7"  
#0 red  
#0 red  
.31 gpm  
.31 gpm  
.28 gpm  
.28 gpm  
.5 gpm  
.5 gpm  
1.2 gpm  
1.2 gpm  
8"  
9"  
10"  
#1 white  
#1 white  
#1 white  
.45 gpm  
.45 gpm  
.45 gpm  
.38 gpm  
.38 gpm  
.38 gpm  
.5 gpm  
.5 gpm  
.5 gpm  
1.5 gpm  
2.0 gpm  
2.4 gpm  
12"  
13"  
#2 blue  
#2 blue  
.84 gpm  
.84 gpm  
.56 gpm  
.56 gpm  
1.0 gpm  
1.0 gpm  
3.5 gpm  
4.0 gpm  
14"  
16"  
#3 yellow  
#3 yellow  
1.0 gpm  
1.0 gpm  
.63 gpm  
.63 gpm  
1.0 gpm  
1.0 gpm  
5.0 gpm  
7.0 gpm  
NOTE: Due to varying water conditions, tank sizes and water pressures, use the above settings as guidelines only.  
1
BLFC (Brine Line Flow Control), refill rate for filling brine tank.  
2
DLFC (Drain Line Flow Control), backwash and rapid rinse flow rates.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Model 5600 & 5600 Econominder®  
General Residential Installation Check List  
Water Pressure  
A minimum of 25 lbs of water pressure is required for regeneration valve to operate effectively.  
Electrical Facilities  
An uninterrupted alternating current (A/C) supply is required. Please make sure voltage supply is compatible with unit  
before installation.  
Existing Plumbing  
Condition of existing plumbing should be free from lime and iron buildup. Replace piping that has heavy lime and/or iron  
build-up. If piping is clogged with iron, install a separate iron filter unit ahead of the water softener.  
Location of Softener and Drain  
Locate the softener close to a clean working drain and connect according to local plumbing codes.  
Bypass Valves  
Always provide for the installation of a bypass valve if unit is not equipped with one.  
CAUTION  
Do not exceed 120 psi water pressure.  
Do not exceed 110°F water temperature.  
Do not subject unit to freezing conditions.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Model 5600 & 5600 Econominder®  
Valve Installation and Start-up Procedures  
1. Place the softener tank where you want to install the unit.  
NOTE: Be sure the tank is level and on a firm base.  
2. During cold weather it is recommended that the installer warm the valve to room temperature before operating.  
3. Perform all plumbing according to local plumbing codes.  
— Use a 1/2" minimum pipe size for the drain.  
— Use a 3/4" drain line for backwash flow rates that exceed 7 gpm or length that exceeds 20(6 m).  
4. Cut the 1" distributor tube (1.050 O.D.) flush with top of each tank.  
NOTE: Only use silicone lubricant.  
5. Lubricate the distributor o-ring seal and tank o-ring seal. Place the main control valve on tank.  
6. Solder joints near the drain must be done before connecting the Drain Line Flow Control fitting (DLFC). Leave at least 6"  
(152 mm) between the DLFC and solder joints when soldering pipes that are connected on the DLFC. Failure to do this  
could cause interior damage to DLFC.  
7. Use only Teflon tape on the drain fitting.  
8. Be sure the floor under the salt storage tank is clean and level.  
9. Place approximately 1" (25 mm) of water above the grid plate. If a grid is not utilized, fill to the top of the air check in the  
salt tank. Do not add salt to the brine tank at this time.  
10. On units with a bypass, place in Bypass position.  
— Turn on the main water supply.  
— Open a cold soft water tap nearby and let water run a few minutes or until the system is free of foreign material  
(usually solder) resulting from the installation. Close the water tap when water runs clean.  
11. Place the bypass in the In Service position and let water flow into the mineral tank. When water flow stops, slowly open  
a cold water tap nearby and let water run until air is purged from the unit. Then close tap.  
12. Plug the valve into an approved power source. When the valve has power it drives to the In Service position.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Model 5600 & 5600 Econominder®  
Model 5600 Installation and Start-up Procedures  
NOTE: Install the water softener with the inlet, outlet and drain connections made according to manufacturer’s  
recommendations and to meet applicable plumbing codes.  
Manual  
Regeneration Knob  
24-Hour Gear  
Skipper Wheel  
(shows every  
other day  
Red Time  
Button  
Set  
regeneration)  
Time of Day Arrow  
Red Pointer  
Figure 1: Model 5600 Softener Control  
1. Manually index the softener control into the In Service position and let water flow into the resin tank. When the water  
flow stops, open a softened water tap until all air is released from the lines. Then close tap.  
NOTE: Manually dial the various regeneration positions by turning the knob on the front of the control until the indicator  
shows that the softener is in the desired position.  
2. Manually index the control to the Backwash position and allow water to flow at the drain for 3 or 4 minutes.  
3. Remove back cover plate.  
4. Make sure that the salt dosage is set as recommended by the manufacturer. If necessary, set salt according to the setting  
instruction sheet. Manually index the control to the Brine Fill position and allow the brine tank to fill to the top of the air  
check.  
5. Manually index the control to the Brine Draw position and allow the control to draw water from the brine tank until it  
stops.  
6. Plug in the electrical cord and look in the sight hole in the back of the motor to see that it is running. Set the days that  
regeneration is to occur by sliding tabs on skipper wheel outward to expose trip fingers.  
— Each tab is one day.  
— Finger at red pointer is tonight.  
— Moving clockwise from red pointer, extend or retract fingers to obtain the desired regeneration schedule.  
7. Manually advance the control to the beginning of the Brine Fill position and allow the control to return to the In Service  
position automatically.  
8. Fill the brine tank with salt.  
9. Replace back cover on the control.  
10. Make sure that any bypass valving is left in the normal In Service position.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Model 5600 & 5600 Econominder®  
Model 5600 Backwash Filter Installation and Start-up Procedures  
NOTE: Install the water softener with the inlet, outlet and drain connections made according to manufacturer’s  
recommendations and to meet applicable plumbing codes.  
Manual  
Regeneration Knob  
24-Hour Gear  
Skipper Wheel  
(shows every  
other day  
Red Time  
Set  
Button  
backwash)  
Time of Day Arrow  
Red Pointer  
Figure 2: Model 5600 Backwash Filter Control  
Before Plugging in the Unit  
1. Open a treated water tap down stream of the filter.  
2. Manually index the filter to the In Service position and allow the mineral tank to fill by slowly opening the main water  
supply valve. Any bypass should be in the In Service position.  
NOTE: The water flowing from the downstream tap is cloudy and/or contains media fines as well as air. Allow the water  
to run until it appears clean and free of air.  
3. When a steady clean flow appears at the tap, close the tap and the main water supply valve and allow the filter media bed  
to settle for 15–20 minutes.  
4. Manually index the filter to the Backwash position.  
5. To prevent a sudden surge of water and air, partially open the main water supply valve so that the flow at the drain of the  
filter is approximately 1 gpm. The water at the drain is cloudy again and/or contains media fines as well as air. Allow  
water to flow at the drain until it appears clean and free of air.  
6. Continue to open the water supply valve until it is completely open. Allow water to flow at the drain until all media fines  
are washed out of the filter.  
7. Manually index the filter to the In Service position, and again open the downstream tap. Check to be sure that the water  
flows clear. If necessary, allow water to flow until all media fines are gone. If the tap is equipped with an aerator check  
that is not plugged with media fines and pipe scale.  
8. Plug in the electrical cord and look in the sight hole on the back of the timer motor to ensure that it is running. Set the days  
backwashing is to occur by sliding tabs on the skipper wheel outward to expose trip fingers. Each tab is one day. Finger at  
red pointer is tonight. Moving clockwise from red pointer, extend or retract fingers to obtain the desired backwash  
schedule.  
9. Set time of day by pushing red button and spin the 24-hour gear until the present time of day is visible above the time of  
day arrow.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Model 5600 & 5600 Econominder®  
Model 5600 Backwash Filter Installation and Start-up Procedures  
(Cont’d.)  
Cycle Times and Flow Diagrams  
1. In Service position. See Figure 4, page 10.  
2. Preliminary Rinse position.  
— Same as Figure 4, page 10 with standard piston (white end plug) or filter piston (black end plug).  
— Eliminated with low water piston (gray end plug).  
3. Backwash position.  
— Same as Figure 6, page 11 with standard piston.  
— 15 minutes with filter piston.  
— 7 minutes with low water piston.  
4. Brine Rinse position.  
— Eliminated, resulting in a 50 minute pause, no water flows during this time.  
5. Slow Rinse position.  
— Eliminated, resulting in a 50 minute pause, no water flows during this time.  
6. Second Backwash position.  
— Same as Figure 9, page 12 with standard piston.  
— 15 minutes with filter piston.  
— 7 minutes with low water piston.  
7. Settling Rinse position.  
— Same as Figure 10, page 13 with standard or filter piston.  
— Eliminate with low water piston.  
8. Brine Tank Refill position.  
— Eliminated, filter is back in service at this time.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Model 5600 & 5600 Econominder®  
Model 5600 Econominder Installation and Start-up Procedures  
NOTE: Install the water softener with the inlet, outlet and drain connections made according to manufacturer’s  
recommendations and to meet applicable plumbing codes.  
Manual Regeneration Knob  
24-Hour Gear  
Program Wheel  
People Dial  
Red Time  
Set  
Button  
Grains Per Gallon  
Water Hardness  
Scale  
Gallons Label  
White Dot  
Figure 3: Model 5600 Econominder  
1. Manually index the softener control to the In Service position and let water flow into the resin tank. When the water flow  
stops, open a softened water tap until all air is released from the lines. Then close tap.  
NOTE: The various regeneration positions may be dialed manually by turning the knob on the front of the control until  
the indicator shows that the softener is in the desired position.  
2. Set water usage program wheel using any one of the following procedures:  
— Typical Residential Application  
To program, just set the time, set the hardness and it automatically monitors system needs and regenerates only when  
necessary. To set time of day press red time set button and turn 24-hour gear until present time of day is at “time of  
day.” Set program wheel by lifting the “people” dial and rotating it so that the number of people in the household is  
aligned with the household grains per gallon water hardness. Release the dial and check for firm engagement at  
setting. This method provides reserve capacity based on 75 gallons per person.  
— Optional Programming Procedures  
Calculate the gallon capacity of the system, subtract the necessary reserve requirement and set the gallons available at  
the small white dot on program wheel gear. Note, drawing shows 850 gallon setting. The capacity (gallons) arrow  
denotes remaining gallons exclusive of fixed reserve.  
3. Rotate program wheel counterclockwise until it stops at Regeneration position.  
4. Manually index the control to the Backwash position and allow water to flow at the drain for 3 or 4 minutes.  
5. Remove back cover plate.  
6. Make sure than the salt dosage is set as recommended by the manufacturer. Manually index the control to the Brine Fill  
position and allow the brine tank to fill to the top of the air check.  
7. Manually index the control to the Brine Rinse position and allow the control to draw water from the brine tank until it  
stops.  
8. Plug in the electrical cord and look in the sight hole in the back of the monitor to see that it is running.  
9. Manually advance the control to the beginning of the Brine Fill position and allow the control to return to the In Service  
position automatically.  
10. Fill the brine tank with salt.  
11. Replace back cover on the control. Be sure cable is not pinched between cover and housing.  
12. Make sure that any bypass valving is left in the normal In Service position.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Model 5600 & 5600 Econominder®  
Water Conditioner Flow Diagrams  
Service Position  
Figure 4: Service Position  
Preliminary Rinse Position  
Figure 5: Preliminary Rinse Position  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Model 5600 & 5600 Econominder®  
Water Conditioner Flow Diagrams (Cont’d.)  
Backwash Position  
Figure 6: Backwash Position  
Brine Position  
Figure 7: Brine Position  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Model 5600 & 5600 Econominder®  
Water Conditioner Flow Diagrams (Cont’d.)  
Slow Rinse Position  
Figure 8: Slow Rinse Position  
Second Backwash Position  
Figure 9: Second Backwash Position  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Model 5600 & 5600 Econominder®  
Water Conditioner Flow Diagrams (Cont’d.)  
Settling Rinse Position  
Figure 10: Settling Rinse Position  
Brine Tank Fill Position  
Figure 11: Brine Tank Fill Position  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Model 5600 & 5600 Econominder®  
Model 5600 Control Valve Drive Assembly  
1
29  
27  
20  
16  
1A  
15  
19  
1A  
22  
5
13  
12  
38  
14  
34  
37  
39  
21  
7
8
6
9
2
30  
35  
25  
23  
3
5
4
11  
26  
28  
5
Figure 12: Model 5600 Control Valve Drive Assembly  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Model 5600 & 5600 Econominder®  
Model 5600 Control Valve Drive Assembly  
Part Number  
Item Number  
No. Req’d  
Description  
1
1
1
14448-010  
14448-011  
14448-012  
15494-01  
15494-03  
13175  
18743  
19659  
11384  
housing, with pin  
housing, with pin drilled for screw  
housing, with pin drilled for thumb screw  
“L” housing, with pin  
“L” housing, with pin drilled for designer  
motor mounting plate  
motor, 120V, 60 Hz  
1
1A  
1
1
2
3
1
1
1
motor, 24V, 60 Hz  
4
5
(2-3)  
(3-5)  
1
screw, motor mtg. and ground wire  
screw, component mounting  
idler gear  
13296  
13017  
13018  
13312  
13164  
13170  
19205  
19205-01  
13011  
6
7
1
idler pinion  
8
1
spring, idler  
9
1
drive gear  
11  
12  
1
main gear and shaft  
1
24-hour gear assembly, silver  
24-hour gear assembly, tan  
cycle actuator gear  
1
13  
14  
15  
16  
19  
1
1
14177  
13300  
13311  
knob, manual regeneration  
ball, 1/4dia.  
spring, detent, skipper wheel  
skipper wheel assembly, 12-day  
skipper wheel assembly, 7-day  
skipper wheel ring  
4
2
1
14381  
14860  
13864  
14457  
13014  
11842  
1
20  
21  
22  
23  
24  
25  
26  
27  
1
2
spring, detent, main gear  
regeneration pointer  
1
1
electrical cord, standard  
wire connector (not shown)  
strain relief  
2
12681  
13547  
13229  
13309  
13437  
13310  
18520  
13348  
13436  
60514  
60514-01  
60514-02  
12473  
12037  
15151  
14176  
14278  
15478  
16715  
14175  
14207  
40214  
1
1
back cover  
1
front label, brown on beige  
front label, blue/silver on black  
rear label, softener  
1
28  
29  
1
1
rear label, filter  
1
tape stripe, brown on beige  
tape stripe, blue on silver  
brine cam assembly, 3-18  
brine cam assembly, 6-36  
brine cam assembly, minutes  
screw-drive mounting  
washer  
1
1
30▲  
1
1
2
1
34  
35▲  
37  
1
1
1
1
1
1
1
1
screw, knob  
38  
valve position dial, standard  
valve position dial, low water  
valve position dial, chemical filter  
valve position dial, filter  
knob label, beige  
39  
knob label, silver  
screw, brine cam  
40▲  
Not used when a filter valve  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Model 5600 & 5600 Econominder®  
Model 5600 and 5600 Econominder Control Valve Drive Assembly  
48  
47  
Backwash Filter Injector Option  
10  
49  
50  
55  
20  
22  
12  
11  
23  
21  
42  
9
8
43  
26  
39  
53  
2
7
14  
52  
34  
33  
32  
2
3
29  
31  
20  
30  
16  
15  
1
17  
46  
19  
27  
28  
16  
20  
22  
51  
18  
24  
23  
42  
21  
4
5
43  
45  
26  
39  
40  
38  
41  
44  
52  
37  
14  
36  
35  
Figure 13: Model 5600 and 5600 Econominder Control Valve Drive Assembly  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Model 5600 & 5600 Econominder®  
Model 5600 and 5600 Econominder Control Valve Drive Assembly  
Item Number  
No. Req’d  
Part Number  
13255  
13242  
Description  
adapter clip (clock or meter)  
seal  
1
2
2-4  
5
5
17772  
silicone seal  
3
4
1
1
1
1
1
6
4
1
1
1
1
1
1
1
1
1
61400-12  
61400-11  
13304  
10244  
12281  
valve body assembly, 1dist.  
valve body assembly, 3/4dist.  
o-ring, distributor tube, 1″  
o-ring, distributor tube, 13/16″  
o-ring, top of tank  
not assigned  
spacer  
piston, standard  
piston, low water  
piston, filter  
piston pin  
piston rod assembly  
piston retainer  
end plug assembly standard, white  
end plug assembly filter, black  
end plug assembly low water, gray  
screw, injector mounting  
adapter coupling  
o-ring, adapter coupling  
screw, adapter coupling (clock or meter)  
o-ring, drain  
5
6
7
8
14241  
13247  
13781  
13852  
10696  
13001  
12953  
13446  
13446-10  
13446-20  
13315  
19228  
13305  
13314  
12638  
13301  
9
10  
11  
12  
13  
14  
15  
16*  
17*  
18  
2
2
4
2-4  
1
19  
2
o-ring, injector  
2
13302  
o-ring, brine spacer  
20▲  
21  
22  
1
1
13303  
13163  
o-ring, injector cover  
injector body  
1
10913U  
injector nozzle, undrilled  
23▲  
24  
25  
26  
27  
28  
29  
30  
31  
32  
33  
34  
35  
36  
37  
38  
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
10914  
10227  
13166  
13172  
12626  
13165  
13167  
12550  
11973  
16098  
11981-01  
10329  
10330  
10332  
12094  
12095  
12097  
injector throat, specify size  
injector screen  
injector cover  
brine valve stem  
brine valve seat  
brine valve cap  
brine valve spacer  
quad ring  
spring, brine valve  
washer, brine valve  
retaining ring  
BLFC fitting nut  
BLFC ferrule  
BLFC tube insert  
BLFC button, .25 gpm  
BLFC button, .50 gpm  
BLFC button, 1.0 gpm  
1
12977  
o-ring, BLFC  
39▲  
40  
41  
42  
43  
44  
45  
46  
47  
48  
49  
50  
51A  
1
1
1
1
1
1
1
1
3
1
1
1
1
1
1
1
1
13245  
13244  
BLFC button retainer  
BLFC fitting, 3/8″  
DLFC button, specify size  
DLFC button retainer  
screen, brine line  
o-ring, DLFC (not shown)  
air disperser  
end plug retainer  
screw  
washer  
13173  
12767  
15348  
13497  
13546  
12112  
13363  
13296  
13398  
13708  
18706  
18706-02  
13308  
13918  
screw  
yoke, brass, 1NPT  
yoke, brass, 3/4NPT  
yoke, plastic, 1NPT  
yoke, plastic 3/4NPT  
drain hose barb  
51B  
52  
53  
BLFC, plug  
1
13857  
brine valve, plug  
54▲  
* not used with meter controls  
used in backwash filter  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Model 5600 & 5600 Econominder®  
Model 5600 Econominder Control Valve Drive Assembly  
29  
1
27  
19  
1A  
20  
18  
21  
13  
12  
7
34  
42  
16  
15  
14  
8
6
9
44  
43  
2
3
4
28  
25  
35  
5
45  
30  
40  
5
11  
23  
24  
22  
37  
38  
39  
41  
Figure 14: Model 5600 Econominder Control Valve Drive Assembly  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Model 5600 & 5600 Econominder®  
Model 5600 Econominder Control Valve Drive Assembly  
Part Number  
Item Number  
No. Req’d  
Description  
1
1
housing, with roll pin  
14448-000  
14488-001  
14448-0  
15494-01  
15494-03  
13175  
1
1
housing, with pin drilled for screw  
housing, with pin drilled for thumb screw  
“L” housing, with pin  
“L” housing, with pin drilled for designer  
motor mounting plate  
motor, 120V, 60 Hz  
motor, 24V, 60 Hz  
1A  
1
1
2
3
1
1
18743  
1
13494  
4
5
2-3  
2-4  
1
11384  
screw, motor mtg. and ground wire  
screw, component mounting  
idler gear  
13296  
6
13017  
7
1
13018  
idler pinion  
8
1
13312  
spring, idler  
9
1
13164  
drive gear  
11  
12  
1
13170  
main gear and shaft  
24-hour gear assembly, silver  
24-hour gear assembly, tan  
cycle actuator gear  
1
19205  
1
19205-01  
13802  
13  
14  
15  
16  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
1
1
14177  
knob, manual regeneration  
ball, 1/4dia.  
spring, detent  
2
13300  
2
14457  
1
13748  
screw, program wheel  
program skipper wheel assembly, specify hardness capacity  
program wheel retainer  
cover label, program wheel  
electrical cord  
1
60405-15  
13806  
1
1
13953  
1
11842  
2
12681  
wire connector  
1
13547  
strain relief  
1
13229  
back cover  
not assigned  
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
13955  
13958  
13310  
18520  
13957  
13960  
60514  
60514-01  
60514-02  
12473  
12037  
13830  
13831  
14253  
14276  
14043  
14910  
14176  
14278  
15478  
14175  
14207  
15151  
40214  
front label, beige  
front label, silver  
28  
29  
30  
rear label, softener  
rear label, filter  
tape stripe, beige  
tape stripe, silver  
brine cam assembly, 3-18  
brine cam assembly, 6-36  
brine cam assembly, minutes  
screw-drive mounting  
washer  
34  
35  
37  
38  
39  
40  
41  
drive pinion, program wheel  
clutch, drive pinion  
spring retainer  
spring  
cable assembly, standard  
cable assembly, extended, right angle  
valve position dial, standard  
valve position dial, low water  
valve position dial, filter  
knob label, beige  
42  
43  
knob label, silver  
44  
45  
screw, knob  
screw, brine cam  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Model 5600 & 5600 Econominder®  
Bypass Valve Assembly, Plastic  
9
10  
11  
12A  
12B  
Figure 15: Bypass Valve Assembly, Plastic  
Part Number  
Item Number  
No. Req’d  
Description  
2
2
2
1
1
1
1
1
1
13305  
o-ring, 119  
9
10  
11  
13255  
clip, mounting  
13314  
screw, hex washer head, #8-18 x 5/8"  
yoke, plastic 1" NPT  
yoke, plastic 3/4"  
yoke, 3/4"  
18706  
12A  
18706-02  
13708  
12B  
13708NP  
13398  
yoke, 3/4" (nickel-plated)  
yoke, 1"  
13398NP  
yoke, 1" (nickel-plated)  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Model 5600 & 5600 Econominder®  
Bypass Valve Assembly, Brass  
9
8
6
5
4
3
1
2
7
6
Figure 16: Bypass Valve Assembly, Brass  
Part Number  
Item Number  
No. Req’d  
Description  
1
1
1
1
1
1
1
1
1
8
1
1
1
17290  
bypass valve body, 3/4"  
bypass valve body, 3/4")  
bypass valve body, 1"  
bypass valve body, 1" (nickel-plated)  
seal, bypass  
17290NP  
13399  
13399NP  
11726  
2
3
4
5
6
7
8
9
11972  
plug, bypass  
11978  
side cover  
13604-01  
15727  
label  
screw  
11986  
side cover  
11979  
lever, bypass  
11989  
screw, hex head, 1/4-14  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Model 5600 & 5600 Econominder®  
Model 5600 Econominder Meter Assembly  
1
2A  
2B  
9
3
4
5
6
7
8
Figure 17: Model 5600 Econominder Meter Assembly  
Part Number  
Item Number  
No. Req’d  
Description  
1
2A  
2B  
3
4
1
1
1
1
4
4
1
4
1
12473  
14038  
15659  
13847  
13509  
13314  
13255  
13821  
13305  
14613  
screw, meter cover assembly  
meter cover assembly, standard  
meter cover assembly, extended range (right angle)  
o-ring, meter cover assembly  
impeller  
4
5
screw, adapter clip  
6
adapter clip  
7
meter body  
8
o-ring, meter body  
9
flow straightener  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Model 5600 & 5600 Econominder®  
Service Instructions  
Replace Time Brine Valve, Injectors and Screen  
1. Unplug electrical cord from outlet.  
2. Turn off water supply to conditioner:  
— If the conditioner installation has a “three valve” bypass system, first open the valve in the bypass line, then close the  
valves at the conditioner inlet and outlet.  
— If the conditioner has an integral bypass valve, put it in the Bypass position.  
— If there is only a shut-off valve near the conditioner inlet, close it.  
3. Relieve water pressure in the conditioner by putting the control in the Backwash position momentarily. Return the control  
to the In Service position.  
4. Disconnect brine tube and drain line connections at the injector body.  
5. Remove the two injector body mounting screws. The injector and brine module can now be removed from the control  
valve. Remove and discard valve body o-rings.  
6. Replace brine valve.  
— Pull brine valve from injector body, also remove and discard o-ring at bottom of brine valve hole.  
— Apply silicone lubricant to new o-ring and reinstall at bottom of brine valve hole.  
— Apply silicone lubricant to o-ring on new valve assembly and press into brine valve hole, shoulder on bushing should  
be flush with injector body.  
7. Replace injectors and screen.  
— Remove injector cap and screen, discard o-ring. Unscrew injector nozzle and throat from injector body.  
— Screw in new injector throat and nozzle, be sure they are seated tightly. Install a new screen.  
— Apply silicone lubricant to new o-ring and install around oval extension on injector cap.  
8. Apply silicone lubricant to three new o-rings and install over three bosses on injector body.  
9. Insert screws with washers through injector cap and injector. Place this assembly through hole in timer housing and into  
mating holes in the valve body. Tighten screws. (Be sure to reinstall brass spacers with injector on model 4600 valve.)  
10. Reconnect brine tube and drain line.  
11. Return bypass or inlet valving to normal In Service position. Water pressure automatically builds in the conditioner.  
NOTE: Be sure to shut off any bypass line.  
12. Check for leaks at all seal areas. Check drain seal with the control in the Backwash position.  
13. Plug electrical cord into outlet.  
14. Set time of day and cycle the control valve manually to assure proper function.  
— Make sure control valve is in the In Service position.  
15. Make sure there is enough brine in the brine tank.  
16. Rotate program wheel counterclockwise until it stops at Regeneration position.  
17. Start regeneration cycle manually if water is hard.  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Model 5600 & 5600 Econominder®  
Service Instructions (Cont’d.)  
Replace Timer  
1. Unplug electrical cord from outlet.  
2. Turn off water supply to conditioner:  
— If the conditioner installation has a “three valve” bypass system, first open the valve in the bypass line, then close the  
valves at the conditioner inlet and outlet.  
— If the conditioner has an integral bypass valve, put it in the Bypass position.  
— If there is only a shut-off valve near the conditioner inlet, close it.  
3. Relieve water pressure in the conditioner by putting the control in the Backwash position momentarily. Return the control  
to the In Service position.  
4. Pull cable out of meter cover. Remove the control valve back cover.  
5. Remove screw and washer at drive yoke. Remove timer mounting screws. The entire timer assembly now lifts off easily.  
6. Put new timer on top of valve. Be sure drive pin on main gear engages slot in drive yoke (rotate control knob if necessary).  
7. Replace timer mounting screws. Replace screw and washer at drive yoke.  
8. Return bypass or inlet valving to normal In Service position. Water pressure automatically builds in the conditioner.  
NOTE: Be sure to shut off any bypass line.  
9. Plug electrical cord into outlet.  
10. Set time of day, program wheel, and salt usage. Cycle the control valve manually to assure proper function. Be sure to  
return the control valve to the In Service position.  
11. Replace the control valve back cover. Be sure grommet at cable hole is in place.  
12. Make sure there is enough brine in the brine tank.  
13. Rotate program wheel counterclockwise until it stops at Regeneration position.  
14. Start regeneration cycle manually if water is hard.  
15. Plug cable into meter cover, rotate cable to align drive flat if necessary.  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Model 5600 & 5600 Econominder®  
Service Instructions (Cont’d.)  
Replace Piston Assembly  
1. Unplug electrical cord from outlet.  
2. Turn off water supply to conditioner:  
— If the conditioner installation has a “three valve” bypass system, first open the valve in the bypass line, then close the  
valves at the conditioner inlet and outlet.  
— If the conditioner has an integral bypass valve, put it in the Bypass position.  
— If there is only a shut-off valve near the conditioner inlet, close it.  
3. Relieve water pressure in the conditioner by putting the control in the Backwash position momentarily. Return the control  
to the In Service position.  
4. Pull cable out of meter cover. Remove the control valve back cover.  
5. Remove screw and washer at drive yoke. Remove timer mounting screws. The entire timer assembly now lifts off easily.  
Remove end plug retainer plate.  
6. Pull upward on end of piston yoke until assembly is out of valve.  
7. Inspect the inside of the valve to make sure that all spacers and seals are in place, and that there is no foreign matter that  
would interfere with the valve operation.  
8. Take new piston assembly as furnished and push piston into valve by means of the end plug. Twist yoke carefully in a  
clockwise direction to properly align it with drive gear. Replace end plug retainer plate.  
9. Place timer on top of valve. Be sure drive pin on main gear engages slot in drive yoke (rotate control knob if necessary).  
10. Replace timer mounting screws. Replace screw and washer at drive yoke.  
11. Return bypass or inlet valving to normal In Service position. Water pressure automatically builds in the conditioner.  
NOTE: Be sure to shut off any bypass line.  
12. Plug electrical cord into outlet.  
13. Set time of day, program wheel, and salt usage. Cycle the control valve manually to assure proper function. Be sure to  
return the control valve to the In Service position.  
14. Replace the control valve back cover. Be sure grommet at cable hole is in place.  
15. Make sure there is enough brine in the brine tank.  
16. Rotate program wheel counterclockwise until it stops at Regeneration position.  
17. Start regeneration cycle manually if water is hard.  
18. Plug cable into meter cover. Rotate cable to align drive flat if necessary.  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Model 5600 & 5600 Econominder®  
Service Instructions (Cont’d.)  
Replace Seals and Spacers  
1. Unplug electrical cord from outlet.  
2. Turn off water supply to conditioner:  
— If the conditioner installation has a “three valve” bypass system, first open the valve in the bypass line, then close the  
valves at the conditioner inlet and outlet.  
— If the conditioner has an integral bypass valve, put it in the Bypass position.  
— If there as only a shut-off valve near the conditioner inlet, close it.  
3. Relieve water pressure in the conditioner by putting the control in the Backwash position momentarily. Return the control  
to the In Service position.  
4. Pull cable out of meter cover. Remove the control valve back cover.  
5. Remove screw and washer at drive yoke. Remove timer mounting screws. The entire timer assembly now lifts off easily.  
Remove end plug retainer plate.  
6. Pull upward on end of piston rod yoke until assembly is out of valve. Remove and replace seats and spacers with fingers.  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Model 5600 & 5600 Econominder®  
Service Instructions (Cont’d.)  
Replace Meter  
1. Unplug electrical cord from outlet.  
2. Turn off water supply to conditioner:  
— If the conditioner installation has a “three valve” bypass system, first open the valve in the bypass line, then close the  
valves at the conditioner inlet and outlet.  
— If the conditioner has an integral bypass valve, put it in the Bypass position.  
— If there is only a shut-off valve near the conditioner inlet, close it.  
3. Relieve water pressure in the conditioner by putting the control in the Backwash position momentarily. Return the control  
to the In Service position.  
4. Pull cable out of meter cover.  
5. Remove two screws and clips at bypass valve or yoke. Pull resin tank away from plumbing Connections.  
6. Remove two screws and clips at control valve. Pull meter module out of control valve.  
7. Apply silicone lubricant to four new o-rings and assemble to four ports on new meter module.  
8. Assemble meter to control valve. Note, meter portion of module must be assembled at valve outlet.  
9. Attach two clips and screws at control valve. Be sure clip legs are firmly engaged with lugs.  
10. Push resin tank back to the plumbing connections and engage meter ports with bypass valve or yoke.  
11. Attach two clips and screws at bypass valve or yoke. Be sure clip legs are firmly engaged with lugs.  
12. Return bypass or inlet valving to normal In Service position. Water pressure automatically builds in the conditioner.  
NOTE: Be sure to shut off any bypass line.  
13. Check for leaks at all seal areas.  
14. Plug electrical cord into outlet.  
15. Set time of day.  
— Make sure control valve is in the In Service position.  
16. Rotate program wheel counterclockwise until it stops at Regeneration position.  
17. Start regeneration cycle manually if water is hard.  
18. Plug cable into meter cover. Rotate cable to align drive flat if necessary.  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Model 5600 & 5600 Econominder®  
Service Instructions (Cont’d.)  
Replace Meter Cover and/or Impeller  
1. Unplug electrical cord from outlet.  
2. Turn off water supply to conditioner:  
— If the conditioner installation has a “three valve” bypass system, first open the valve in the bypass line, then close the  
valves at the conditioner inlet and outlet.  
— If the conditioner has an integral bypass valve, put it in the Bypass position.  
— If there is only a shut-off valve near the conditioner inlet, close it.  
3. Relieve water pressure in the conditioner by putting the control in the Backwash position momentarily. Return the control  
to the In Service position.  
4. Pull cable out of meter cover.  
5. Remove four screws on cover  
6. Lift cover off of meter module, discard o-ring.  
7. Remove and inspect impeller for gear or spindle damage, replace if necessary.  
8. Apply silicone lubricant to new o-ring and assemble to the smallest diameter on meter cover.  
9. Assemble cover to meter module. Be sure impeller spindle enters freely into cover. Press firmly on cover and rotate if  
necessary to assist in assembly.  
10. Replace four screws and tighten.  
11. Return bypass or inlet valving to normal In Service position. Water pressure automatically builds in the conditioner.  
NOTE: Be sure to shut off any bypass line.  
12. Check for leaks at all seal areas.  
13. Plug electrical cord into outlet.  
14. Set time of day.  
— Make sure control valve is in the In Service position.  
15. Rotate program wheel counterclockwise until it stops at Regeneration position.  
16. Start regeneration cycle manually if water is hard.  
17. Plug cable into meter cover. Rotate cable to align drive flat if necessary.  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Model 5600 & 5600 Econominder®  
Model 5600 and 5600 Econominder Troubleshooting  
PROBLEM  
CAUSE  
CORRECTION  
1. Softener fails to regenerate.  
A. Electrical service to unit has been  
interrupted.  
A. Assure permanent electrical service  
(check fuse, plug, pull chain or  
switch).  
B. Timer is defective.  
C. Power failure.  
B. Replace timer.  
C. Reset time of day.  
A. Close bypass valve.  
B. Add salt to brine tank and maintain  
salt level above water level.  
2. Softener delivers hard water.  
A. Bypass valve is open.  
B. No salt in brine tank.  
C. Injectors or screen is plugged.  
C. Replace injectors and screen.  
D. Insufficient water flowing into brine tank.  
D. Check brine tank fill time and clean  
brine line flow control if plugged.  
E. Hard water tank hardness.  
F. Leak at distributor tube.  
G. Internal valve leak.  
E. Repeated flushings of the hot water  
tank is required.  
F. Make sure distributor tube is not  
cracked. Check o-ring and tube pilot.  
G. Replace seals and spacers and/or  
piston.  
3. Unit uses too much salt.  
4. Loss of water pressure.  
A. Improper salt setting.  
B. Excess water in brine tank.  
A. Check salt usage and salt setting.  
B. See problem number 7.  
A. Iron build-up in line to water conditioner.  
B. Iron build-up in water conditioner.  
A. Clean line to water conditioner.  
B. Clean control and add resin cleaner to  
resin bed. Increase frequency of  
regeneration.  
C. Inlet of control plugged due to foreign  
material loose from pipes by recent work  
done on plumbing system.  
C. Remove piston and clean control.  
5. Loss of resin through drain line. A. Air in water system.  
A. Assure that well system has proper air  
elimination control, check for dry  
well condition.  
6. Iron in conditioned water.  
A. Fouled resin bed.  
A. Check backwash, brine draw and  
brine tank fill, increase frequency of  
regeneration, increase backwash  
time.  
7. Excessive water in brine tank.  
8. Salt water in service line.  
A. Plugged drain line flow control.  
A. Plugged injector system.  
B. Timer not cycling.  
A. Clean flow control.  
A. Clean injector and replace screen.  
B. Replace timer.  
C. Foreign material in brine valve.  
D. Foreign material in brine line flow control.  
C. Clean or replace brine valve.  
D. Clean brine line flow control.  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Model 5600 & 5600 Econominder®  
Model 5600 and 5600 Econominder Troubleshooting (Cont’d.)  
PROBLEM  
CAUSE  
CORRECTION  
9. Softener fails to draw brine.  
A. Draw line flow control is plugged.  
B. Injector is plugged.  
A. Clean drain line flow control.  
B. Clean or replace injectors.  
C. Replace screen.  
C. Injector screen plugged.  
D. Line pressure is too low.  
D. Increase line pressure (minimum 20  
psi at all times).  
E. Internal control leak.  
E. Change seals, spacers and/or piston  
assembly.  
10. Control cycles continuously.  
11. Drain flows continuously.  
A. Faulty timer mechanism.  
A. Foreign material in control.  
A. Replace timer.  
A. Remove piston assembly and inspect  
bore, remove foreign material and  
check control in various regeneration  
positions.  
B. Internal control leak.  
B. Replace seals and/or piston assembly.  
C. Replace seals and/or piston assembly.  
C. Control valve jammed in Brine or  
Backwash position.  
D. Timer motor stopped or jammed.  
D. Replace timer.  
General Service Hints for Meter Control  
PROBLEM  
CAUSE  
CORRECTION  
Softener delivers hard water.  
A. Reserve capacity has been exceeded.  
A. Check salt dosage requirements and  
reset program wheel to provide  
additional reserve.  
B. Program wheel is not rotating with meter  
output.  
B. Pull cable out of meter cover and  
rotate manually, program wheel  
must move without binding and  
clutch must give positive "clicks"  
when program wheel strikes  
regeneration stop (if not, replace  
timer).  
C. Meter is not measuring flow.  
C. Check output by observing rotation  
of small gear on front of timer  
(program wheel must not be against  
regeneration stop for this check)  
each tooth to tooth is approximately  
30 gallons (if not, replace meter).  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Model 5600 & 5600 Econominder®  
Model 5600SF Troubleshooting  
PROBLEM  
CAUSE  
CORRECTION  
1. Filter fails to backwash.  
A. Electrical service to unit has been  
interrupted.  
A. Assure permanent electrical service  
(check fuse, plug, pull chain or  
switch).  
B. Timer is defective.  
C. Power failure.  
B. Replace timer.  
C. Reset time of day.  
A. Close bypass valve.  
B. Reduce days between, backwashing  
(see timer instructions), make sure  
that there is not a leaking valve in the  
toilet bowl or sinks.  
2. Filter "bleeds" iron.  
A. Bypass valve is open.  
B. Excessive water usage.  
C. Hot water tank rusty.  
C. Repeated flushings of the hot water  
tank is required.  
D. Leak at distributor tube.  
D. Make sure distributor tube is not  
cracked, check o-ring and tube pilot.  
E. Defective or stripped filter medium bed.  
F. Inadequate backwash flow rate.  
E. Replace bed.  
F. Make sure filter has correct drain  
flow control, be sure flow control is  
not clogged or drain line restricted, be  
sure water pressure has not dropped,  
increase backwash flow rate  
according to specifications for your  
unit, see your dealer for  
recommendations.  
3. Loss of water pressure.  
A. Iron or turbidity build-up in water filter.  
A. Reduce days between backwashing  
so filter backwashes more often,  
make sure filter is sized large enough  
to handle water usage.  
B. Inlet plugged due to foreign material  
broken loose from pipes by recent work  
done on plumbing system.  
B. Remove piston and clean control.  
4. Loss of filter medium through  
drain line.  
A. Broken or missing top screen.  
A. Replace top screen, must have 0.020"  
wide slots.  
5. Drain flows continuously.  
A. Foreign material in control.  
A. Remove piston assembly and inspect  
bore, remove foreign material and  
check control in various cycle  
positions.  
B. Internal control leak.  
B. Replace seals and/or piston assembly.  
C. Control valve jammed in rinse or  
backwash.  
C. Replace piston, seals and spacers  
(and drive motor if necessary).  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Model 5600 & 5600 Econominder®  
Service Assemblies  
Part Number  
Description  
60102-00  
60102-10  
60102-20  
piston, softener  
piston, filter  
piston, low water  
60125  
60084-XX  
60032  
seal kit  
injector  
brine valve  
60514  
60514-01  
60514-02  
brine cam, 3-18  
brine cam, 6-36  
brine cam, minutes  
60510  
coupling, with clip and screws  
60040  
60041  
60049  
bypass, brass 3/4" NPT  
bypass, brass 1" NPT  
bypass, plastic  
60086  
60087  
meter, standard  
meter, extended  
160136-5600  
160135-5600  
service kit, meter  
service kit, clock  
14860  
14381  
skipper wheel, 7-day  
skipper wheel, 12-day  
60405-10  
60405-20  
meter program wheel, standard  
meter program wheel, extended  
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Model 5600 & 5600 Econominder®  
Notes:  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Model 5600 & 5600 Econominder®  
Notes:  
34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
P/N 40106  
Rev. H 05/05  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Peavey Car Speaker PV 15 PM User Manual
Pelco Car Video System C2931M97 05 User Manual
Pfaff Sewing Machine 463 AND 463 H User Manual
Philips CRT Television TC User Manual
Philips Digital Photo Frame SPY3010 User Manual
Philips Model Vehicle AT751 User Manual
Pioneer Blu ray Player BDP LX71 User Manual
Pioneer CD Player CDJ 850 User Manual
Pioneer CD Player HTD88DVD User Manual
Porter Cable Drill 2610 User Manual